SOLUTIONS FOR THE CONTROL OF THE WHOLE BUILDING

Similar documents
Basics of Dimming. ISC Learning Centre

Integrated solutions for comfort, energy efficiency, safety, video door entry, and control

How To Use A Power Supply On A Powerline 2.2 (Ai)

KNX Lighting Control System

How To Build A Home Automation System On A Tv Remote Control

DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34)

Thermostat with display

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB.

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Inwall 4 Input / 4 Output Module

HOTEL ROOM MANAGEMENT SYSTEM - specifications OVERVIEW

Passion for KNX innovation

Product and functional description

EIB/KNX IP Interface with Power over Ethernet (PoE)

MY HOME - CONTROL 130

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

CONTENTS. Radio system catalogue. Catalogue MY HOME 527

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX Switch Actuators SA/S Product Information

13 SERIES. Electronic step relays A

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Climate Ready Control Systems Technical Specifications

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

F454. Web Server. User Manual 05/12-01 PC

ABB i-bus KNX Fan Coil Controller FC/S 1.1

video door entry system offer

Product data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System

Lighting Management solutions

Technical Manual MDT Rain sensor

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

USER MANUAL FOR DRIVER RTI & HDL. Driver User Guide January Index. 1 Overview Driver Option... 3

KNX IP INTERFACE IN00A02IPI. Operating and installation manual

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

IntesisBox KNX Modbus TCP master

ABB i-bus EIB Logic Module LM/S 1.1

Temperature & Humidity SMS Alert Controller

KNX Panasonic Air Conditioners

SFERA. NEw. 2 wire. audio ViDEO PUSHBUTTON PANELS

Inwall Room Temperature Unit

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

PCS0100en Persy Control Services B.V. Netherlands

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

Building Technologies

Electronic Control Devices The European Product Catalogue 2007

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

40.3. Control Relays and Timers

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

IntesisBox KNX Modbus RTU master

Unica for KNX system 226

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Climate Ready Shade Operating Systems for residential applications.

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

IntesisBox KNX - LON

HERZ-Thermal Actuators

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Niko Home Control. Installation Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX IP Router IPR/S 2.1

KNX Powerline PL 110. KNX Association

The house is a machine for living. Le Corbusier, Toward an Architecture, 1923

basicdim DGC Compact control module

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Power Line Carrier technology

RELAX IT DOES THE REST GUEST ROOM CONTROL SYSTEM FOR HOSPITALITY BUILDINGS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Voltage Regulator SPAU 341 C. Product Guide

Product and Application Description

F453. TiF453. User guide 10/11-01 PC

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

NC-12 Modbus Application

KNX System Principles

Building Service Management System instabus EIB

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

IntesisBox KNX LG Air Conditioning

API Marine. BMS Presentation. Ballast Measurement Systems

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

Highly flexible the right KNX/DALI gateway for every requirement

386 MY HOME Video door entry and home video surveillance system

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

CONTENTS MY HOME - VIDEO DOOR ENTRY AND HOME VIDEO SURVEILLANCE SYSTEM

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Duct Humidity Transmitter

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

MyHOME_Suite. Version: Date: 26th October 2015

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

HCE80/HCC80/HCE80R/HCC80R

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

EBDSPIR-PRM, EBDSPIR-PRM-IP

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

D45. SySTEm. ThE high-performance

Transcription:

AUTOMATION SYSTEM Catalogue SOLUTIONS FOR THE CONTROL OF THE WHOLE BUILDING

automation system

Contents 4-11 Catalogue Control devices 4 Sensors 5 Modular controllers 6 False ceiling controllers and Automation 8 Gateway and interfaces 9 Infrastructure devices 10 Software and integration 11 12-16 Dimensional data Control devices 14 Sensors 14 Modular controllers 15 False ceiling controllers and automation 16 Gateway and interfaces 16 Infrastructure devices 16 KNX CATALOGUE 1

automation system 5.7 KNX TOUCH SCREEN DISPLAY Global and integrated management Solutions for the control of the whole building. 4 CHANNEL KNX CONTROL - LIVINGLIGHT 2 The automation offer of BTicinoLegrand complies with the international KNX standard, the most used technology for the intelligent management of buildings.

(QR code) FOR EACH PRODUCT, THE ETS DATABASE CAN BE DOWNLOADED FROM THE WEBSITE "WWW. LEGRANDOC.COM" ETS SOFTWARE FOR THE CONFIGURATION OF KNX DEVICES. KNX THERMOSTAT KNX/IP GATEWAY FOR THE INTERFACING OF KNX SYSTEMS TO THE IP NETWORK KNX MULTIAPPLICATION CONTROLLERS KNX ACTUATOR FOR THE CONTROL OF SOLAR PROTECTION DEVICES PASSIVE INFRARED AND ULTRASOUND (PIR + US) KNX GREEN SWITCH 4 CHANNEL KNX CONTROL WITH SCENARIO FINISH KNX CATALOGUE 3

KNX Control devices H4651KNX HD4680KNX LN4651KNX NT4680KNX HD4657M3KNX HS4657M3KNX 4 H4651KNX HD4680KNX HC4680KNX HS4680KNX LN4651KNX 4 CHANNEL KNX CONTROL DEVICES Axolute, 4 channel KNX control without finishing accessories. - 1 or 2 pushbuttons switch/dimmer - 1 or 2 pushbuttons shutter/shutter blade management - value forwarding (shutter position, dimmer %...) - forwarding of sequential values - forwarding of priority commands - forwarding of multiple commands - forwarding of conditional commands - recalling / saving of 1 and 8 bit scenarios SELV 29 Vdc supply voltage from KNX bus. Installation in residential series, to be completed with key covers, support and Axolute cover plate. Size: 2 modules. Axolute, 4 channel KNX control with scenario finish. - 1 or 2 pushbuttons switch/dimmer - 1 or 2 pushbuttons shutter/shutter blade management - value forwarding (shutter position, dimmer %...) - forwarding of sequential values - forwarding of priority commands - forwarding of multiple commands - forwarding of conditional commands - recalling / saving of 1 and 8 bit scenarios SELV 29 Vdc supply voltage from KNX bus. Installation in residential series, to be completed with support and Axolute cover plate. Size: 2 modules. LivingLight, 4 channel KNX control without finishing accessories. - 1 or 2 pushbuttons switch/dimmer - 1 or 2 pushbuttons shutter/shutter blade management - value forwarding (shutter position, dimmer %...) - forwarding of sequential values - forwarding of priority commands - forwarding of multiple commands - forwarding of conditional commands - recalling / saving of 1 and 8 bit scenarios SELV 29 Vdc supply voltage from KNX bus. Installation in residential series, to be completed with key covers, support and Livinglight cover plate. Size: 2 modules. * For the availability of the product, contact the BTicino commercial representative. NOTE: White device N4680KNX NT4680KNX L4680KNX HD4657M3KNX * HC4657M3KNX * HS4657M3KNX * HD4657M4KNX * HC4657M4KNX * HS4657M4KNX * Tech device 4 CHANNEL KNX CONTROL DEVICES Livinglight, 4 channel KNX control with scenario finish. - 1 or 2 pushbuttons switch/dimmer - 1 or 2 pushbuttons shutter/shutter blade management - value forwarding (shutter position, dimmer %...) - forwarding of sequential values - forwarding of priority commands - forwarding of multiple commands - forwarding of conditional commands - recalling / saving of 1 and 8 bit scenarios SELV 29 Vdc supply voltage from KNX bus. Installation in residential series, to be completed with support and Livinglight cover plate. Size: 2 modules. 6 CHANNEL KNX CONTROL DEVICES Axolute, 6 channel KNX glass control, transparent colour. - 1 or 2 pushbuttons switch/dimmer - 1 or 2 pushbuttons shutter/shutter blade management - value forwarding (shutter position, dimmer %...) - forwarding of sequential values - forwarding of priority commands - forwarding of multiple commands - forwarding of conditional commands - recalling / saving of 1 and 8 bit scenarios SELV 29 Vdc supply voltage from KNX bus. Installation in civil series. Size: 3 modules. control as above, whice colour control as above, nighter colour 8 CHANNEL KNX CONTROL DEVICES Axolute, 8 channel KNX glass control, transparent colour. - 1 or 2 pushbuttons switch/dimmer - 1 or 2 pushbuttons shutter/shutter blade management - value forwarding (shutter position, dimmer %...) - forwarding of sequential values - forwarding of priority commands - forwarding of multiple commands - forwarding of conditional commands - recalling / saving of 1 and 8 bit scenarios SELV 29 Vdc supply voltage from KNX bus. Installation in civil series. Size: 4 modules. Anthracite device Neutral item

KNX Control devices KNX Sensors 0 4 31 THERMOSTAT 0 4 31 KNX thermostat for the management of 2/4 or 2 tube fan-coil convectors with electric heater. Fitted with: 2 valve outputs, 3 fan-coil speed adjustment outputs, and 2 freely configurable inputs for window contact, dew point probe, badge contact... - preservation of the ambient temperature through built-in or external temperature sensor - switching between manual and automatic sensor driven cooling/heating - selection of the operating mode using the onboard pushbutton - 3 speed fan control (automatic or manual) - measured temperature or configured set-point display, C or F - advanced fan control functions (kick fan, fan start...) Supply voltage 230 Vac. Semi-flush mounted wall installation 0 489 18 0 489 19 0 489 21 SENSORS 0 489 18* Ceiling mounted double technology KNX sensor, passive infrared and ultrasound (PIR+US), protection degree IP20. Ideal for installation in working areas (e.g. offices, conference and meeting rooms...). SELV 29 Vdc supply voltage from KNX bus. Flush mounted false ceiling or masonry ceiling installation using flush mounting boxes or springs; ceiling mounted installation using accessory item 048875 0 489 19* Ceiling mounted KNX PIR sensor, IP20 protection index. Ideal for installation in the centre of the corridor SELV 29 Vdc supply voltage from KNX bus. Flush mounted false ceiling or masonry ceiling installation using flush mounting boxes or springs; ceiling mounted installation using accessory item 048875 0 489 20* Wall mounted KNX sensor with double technology, passive IR and ultrasound (PIR+US), IP42 protection index. Ideal for installation in working areas (e.g. offices, conference and meeting rooms...). SELV 29 Vdc supply voltage from KNX bus. Wallmounted installation 0 489 21* Wall mounted KNX PIR sensor, IP55 protection index. Ideal for installation of open transit areas (e.g. car parks...). SELV 29 Vdc supply voltage from KNX bus. Wall mounted or ceiling installation * For the availability of the product, contact the BTicino commercial representative. NOTE: White device Tech device Anthracite device Neutral item KNX CATALOGUE 5

KNX Sensors KNX Modular controllers N4658KNX HS4658KNX 0 026 35 0 026 40 0 026 59 N4658KNX* NT4658KNX* L4658KNX* HD4658KNX* HC4658KNX* HS4658KNX* GREEN SWITCH SENSORS KNX PIR Green Switch, IP20 protection index. With on-board pushbutton, ideal for installation in passage areas (e.g. corridors, entrance halls, bathrooms...). Supply voltage SELV 29 Vdc from KNX bus. Installation in residential series, to be completed with support and Livinglight cover plate. Size: 2 modules. KNX PIR Green Switch, IP20 protection index. With on-board pushbutton, ideal for installation in passage areas (e.g. corridors, entrance halls, bathrooms...). Supply voltage SELV 29 Vdc from KNX bus. Installation in residential series, to be completed with support and Livinglight cover plate. Size: 2 modules. MODULAR CONTROLLERS 0 026 35 KNX/DALI Gateway for the control of DALI ECG (Electronic control gear), with one output with a maximum load of 64 ECG. It gives the possibility of managing the ECGs in different modes: all in the same way, in groups, individually; or to program up to 16 different lighting scenarios. The gateway also gives the possibility of receiving return information from the system (ECG fault, lamp fault...). Supply voltage 110-240 V 50-60 Hz, and additional power supply from KNX bus. Fitting on DIN rail. Size: 6 DIN modules. 0 026 40 KNX actuator for the control of solar protection devices (shutters, Venetian blinds). Fitted with 4 interlocking relays with maximum load of 2.1 A at 230 Vac. - venetian blinds up/down movement - blade adjustment - emergency opening in case of wind alarm Supply voltage SELV 29 Vdc from KNX bus. Fitting on DIN rail. Size: 4 DIN modules. 0 026 59* Universal 2 channel KNX dimmer with maximum load 1.7A when used separately, and 3.4A when used in parallel for the control of light loads. When associating up to three expansions, item 002660, it is possible to control up to 6 circuits. - ON/OFF switching - Manual or automatic dimmer using brightness sensors - Scenario control - Dimmer speed configuration - Minimum/maximum dimmer level setting Supply voltage 110-240V 50-60 Hz. Fitting on DIN rail. Size: 4 DIN modules. * For the availability of the product, contact the BTicino commercial representative. 6 NOTE: White device Tech device Anthracite device Neutral item

KNX Modular controllers MODULAR CONTROLLERS 0 026 60* Two channel expansion for universal KNX dimmer, item 002659. Bus connection using a red-black KNX connector. Supply voltage 110-240 V, 50-60 Hz. Fitting on DIN rail. Size: 4 DIN modules. 0 026 61* KNX actuator with 4 independent channels, each with maximum load 8 A, suitable for the control of light loads. - selection of the operating mode (normal or timed switch) - ON/OFF switching - ON/OFF switching with delay - timed ON switching - Configure the AND/OR logic operations for each channel Supply voltage 110-240 V 50-60 Hz. Fitting on DIN rail. Size: 4 DIN modules. 0 026 62* KNX actuator with 8 independent channels, each with maximum load 8 A, suitable for the control of light loads. - selection of the operating mode (normal or timed switch) - ON/OFF switching - ON/OFF switching with delay - timed ON switching - Configure the AND/OR logic operations for each channel Supply voltage 110-240 V 50-60 Hz. Fitting on DIN rail. Size: 4 DIN modules. 0 026 63* KNX/DALI interface with 8 independent channels, each capable of managing up to 8 ballasts. - Switching, dimmer and forwarding of a dimmer level value - Configuration of ON / OFF switching times, dimmer from 0 to 100 % and from 100 to 0% - Configuration of the minimum / maximum dimmer level - Configuration of 8 bit scenarios for each channel, with the possibility to assign up to 16 scenarios to one channel - Configuration of the objects for the return of the status relating to lamp switching/ dimmer/fault, and DALI status Supply voltage 110-240 V 50-60 Hz. Fitting on DIN rail. Size: 4 DIN modules. 0 026 61 0 484 22 MODULAR CONTROLLERS 0 026 64* KNX actuator with 4 independent channels, each with maximum load 16 A, suitable for the control of light loads or controlled sockets. - selection of the operating mode (normal or timed switch) - ON/OFF switching - ON/OFF switching with delay - timed ON switching - Configure the AND/OR logic operations for each channel Supply voltage SELV 29 Vdc from KNX bus. Fitting on DIN rail. Size: 4 DIN modules. 0 484 18 Multiple application KNX controller with 8 inputs and 10 outputs, capable of performing several functions, including: - ON-OFF lighting control or dimmer - Rolling shutter control - Control of controlled sockets - Measurement of the consumptions of the connected loads (some outputs only) Each output can be controlled using traditional electromechanical devices or KNX devices, and can be configured for operation following three different operating profiles. Bus connection using a red-black KNX connector. Supply voltage 27/-50 Vac Fitting on DIN rail. Size: 8 DIN modules. 0 484 22 Multiple application KNX controller with 16 inputs and 16 outputs, capable of performing several functions, including: - ON-OFF lighting control or dimmer using DALI protocol - Rolling shutter control - Control of controlled sockets - Measurement of the consumptions of the connected loads (some outputs only) Each output can be controlled using traditional electromechanical devices or KNX devices, and can be configured for operation following three different operating profiles. Supply voltage 110-240 V 50-60 Hz. Fitting on DIN rail. Size: 12 DIN modules. * For the availability of the product, contact the BTicino commercial representative. NOTE: Neutral item KNX CATALOGUE 7

KNX False ceiling controllers and Automation 0 488 61 0 488 62 0 488 64 0 488 84 CEILING CONTROLLERS 0 488 61 Dimmer KNX Room Controller for halogen lamps. With 2 independent outputs, each with maximum load 4.3A at 230Vac, 1 SCS bus input with maximum delivery 200 ma, for the connection of SCS commands and sensors, and one riser KNX input with clamp connection. It gives the possibility of interfacing SCS products to the KNX bus (for the list of compatible product see the "KNX automation system" guide). Supply voltage 100/240 V a.c. 50/60 Hz. False ceiling installation. 0 488 62 KNX 1-10V Room Controller. With 4 independent outputs, each with maximum load 4.3A at 230Vac, 1 SCS bus input with maximum delivery 200 ma, for the connection of SCS commands and sensors, and one riser KNX input with clamp connection. It gives the possibility of interfacing SCS products to the KNX bus (for the list of compatible product see the "KNX automation system" guide). Supply voltage 100/240 V a.c. 50/60 Hz. False ceiling installation. 0 488 64 KNX DALI Room Controller. With 4 independent outputs, each capable of driving up to 32 ballasts, 1 SCS bus input with maximum delivery 200 ma for the connection of SCS commands and sensors, and one riser KNX input with clamp connection. It gives the possibility of interfacing SCS products to the KNX bus (for the list of compatible product see the "KNX automation system" guide). Supply voltage 100/240 V a.c. 50/60 Hz. False ceiling installation. 0 488 66 KNX DALI Room Controller. With 8 independent outputs, each capable of driving up to 16 ballasts, 1 SCS bus input with maximum delivery 200 ma for the connection of SCS commands and sensors, and one riser KNX input with clamp connection. It gives the possibility of interfacing SCS products to the KNX bus (for the list of compatible product see the "KNX automation system" guide). Supply voltage 100/240 V a.c. 50/60 Hz. False ceiling installation. AUTOMATION 0 026 50* KNX scenarios/events module It can be used in a KNX system for saving and recalling scenarios/ events. Programming and recalling of 8 scenarios including up to 8 different actuations Management of data types from 1 bit to 14 bytes Saving and recalling of scenarios through 1 bit activation commands, or 8 bit scenario telegrams Variable time delay for the forwarding of telegrams from 0 to 30 minutes, upon recalling of a scenario Programming and recalling of up to 8 different events consisting of up to 10 activities maximum Possibility of activation of events, based on reference values or conditions Variable time delay from 0 to 120 minutes for each event Supply voltage SELV 29 Vdc from KNX bus. Fitting on DIN rail. Size 1 DIN module. 0 488 84 320x240 pixels 5.7" KNX touch screen display with backlighting LED. It gives the possibility of managing 40 KNX functions on 5 different pages. Possible functions: - switching/variation of light loads - control of motorised driving devices - temperature setting - selection of the operating mode and setting of the fan speed for HVAC devices - recalling of pre-configured scenarios - display of load status information Supply voltage 29 Vdc SELV from KNX bus and supply voltage 230 Vac 50/60 hz. Wall and flush mounted installation. 8 * For the availability of the product, contact the BTicino commercial representative. NOTE: Neutral item

KNX Gateway and interfaces 0 026 34 0 035 43 0 026 55 0 484 21 GATEWAY AND INTERFACES 0 026 34 KNX/SCS gateway. It gives the possibility of interfacing SCS products to the KNX bus (for the list of compatible product see the "KNX automation system" guide). The products connected are detected and configured by the ETS as if they were native KNX products. The reference consists of two products, gateway, and SCS power supply. Connection to the KNX bus using the red-black KNX connector, and to the SCS bus using the RJ connector. Power supply unit: 100/240 Vac 50/60 Hz, external; gateway power supply: 27 Vdc, external. Fitting on DIN rail: 2 DIN modules for power supply and 2 DIN modules for the controller. 0 026 38* KNX/IP gateway with router, for the connection of KNX lines through computer networks using the IP protocol. The device also allows for simultaneous access to the BUS KNX line from any PC or data processing device connected to the network. - Simple IP (Internet Protocol) connection to BUS KNX systems - Direct access to the KNX installation from any point of the IP network (KNXnet/IP tunnelling) - Quick communication among lines, KNX system areas (KNXnet/IP routing) - Filtering and routing of telegrams SELV 29 Vdc supply voltage from KNX bus. Fitting on DIN rail. Size: 2 DIN modules. 0 035 43 KNX/IP Gateway for the management of KNX systems using the web network. With built-in web server for access from the web browser of the PC or mobile device, it gives the possibility of displaying up to 40 KNX functions on a maximum of 5 pages Possible functions: - switching/variation of light loads - control of motorised driving devices - temperature setting - selection of the operating mode and setting of the fan speed for HVAC devices - recalling of pre-configured scenarios - display of load status information Connection to the Bus using a red-black and white-yellow KNX connector. Supply voltage SELV 29 Vdc from KNX bus. Fitting on DIN rail. Size: 5 DIN modules. * For the availability of the product, contact the BTicino commercial representative. NOTE: Neutral item GATEWAY AND INTERFACES 0 026 55* KNX contact interface with 8 independent channels. It can be used for monitoring different devices, like probes, alarms, etc... - Recording of the switching of status (open/ closed), and of the status changes (opening/ closing), of the different contacts - Monitoring of the switching status, and of the operating status of the contacts (status of connected devices, alarms...) - Recording of the switching status of the contacts and count of the number of switches, and comparison with preset reference thresholds KNX bus connection using a red-black KNX connector. Supply voltage 100/240 V a.c. 50/60 Hz. Fitting on DIN rail. Size: 6 DIN modules. 0 484 20* 2 channel KNX contact interface. It can be used for the interfacing of traditional electromechanical KNX bus controls. The 2 channels are fitted with LEDs and can be configured as inputs or outputs (status return). - 1 or 2 pushbuttons switching/dimmer - 1 or 8 bit scenario control - 1or 2 pushbuttons shutter control - forwarding of sequential values - forwarding of multiple values - 8/16/32 bit meter, with or without threshold control KNX bus connection using a red-black KNX connector. Supply voltage 100/240 Vac 50/60 Hz. Installation in flush-mounted box 0 484 21* 4 channel KNX contact interface. It can be used for the interfacing of traditional electromechanical KNX bus controls. The 4 channels are fitted with LEDs and can be configured as inputs or outputs (status return). - 1 or 2 pushbuttons switching/dimmer - 1 or 8 bit scenario control - 1or 2 pushbuttons shutter control - forwarding of sequential values - forwarding of multiple values - 8/16/32 bit meter, with or without threshold control KNX bus connection using a red-black KNX connector. Supply voltage 100/240 V a.c. 50/60 Hz. Installation in flush-mounted box KNX CATALOGUE 9

KNX Infrastructure devices 0 035 12 0 035 16 0 035 47 0 492 91 INFRASTRUCTURE 0 035 04* KNX modular power supply Input voltage: 230 V +10% to -15%, 50-60 Hz. Output voltage: 29 V ±1 Vdc SELV. Output current: 640 ma. Fitting on DIN rail. Size: 4 DIN modules. 0 035 12 KNX modular power supply Input voltage: 230 V +10% to 15%, 50-60 Hz. Output voltage: 29 V ±1V dc SELV. Output current: 320 ma. Fitting on DIN rail. Size: 4 DIN modules. 0 035 16 KNX coupler, to be used for data exchange between two KNX lines. It may be used as: - line coupling unit (for coupling one line to a main line) - backbone coupling unit (for coupling a main line to the backbone line) - repeater (for coupling two segments of the same line) SELV 29 Vdc supply voltage from KNX bus. Fitting on DIN rail. Size: 2 DIN modules. 0 035 47 KNX/USB opto-insulated interface for the connection of a PC for the addressing, parameter definition, logging display, and diagnostics of KNX systems. Fitted with type B USB connector. USB 1.1 transmission (max. 12 Mbit/s). Direct supply from the bus line through USB connection. Fitting on DIN rail. Size: 1 DIN modules. 0 488 79* Automatic plastic KNX clamp, red-black colour. It can be used to connect the products, extend or distribute the cable, and protect the cable terminals. INFRASTRUCTURE 0 492 91 KNX cable with single pair of twisted conductors (red-black). It may be installed side by side with the 230 V supply cable and is indicated for protruding and flush mounted installation, for installation inside conduits, in dry outdoor areas, provided that protection from sunlight is ensured. Test voltage: 4 kv rated diameter 6.1 mm. Length (in m): 500. 0 492 92* KNX cable with double pair of twisted conductors (red-black and white-yellow). It may be installed side by side with the 230 V supply cable and is indicated for protruding and flush mounted installation, for installation inside conduits, in dry outdoor areas, provided that protection from sunlight is ensured. Test voltage: 4 kv rated diameter 6.1 mm. Length (in m): 500. 10 * For the availability of the product, contact the BTicino commercial representative. NOTE: Neutral item

KNX Supervision and integration software 0 035 44 0 4 04 INFRASTRUCTURE 0 035 44 Devices for automatic management of service sector buildings where interoperability among different systems is required: - BTicino-Legrand solutions: Lighting management, safety lighting, load control, fire alarms; - other solutions: HVAC, etc. - It guarantees: - the management of the data from systems based on the following protocols: KNX, MODBUS, BACNET, SCS; - the programming of scripts (with algorithms), alarms, and data logging; - the exchange of data from various systems (example: display of consumption values measured on the power circuit); - the management of HVAC systems (air conditioning, heating); - the forwarding of e-mails in case of alarm. - It can be installed inside rack cabinets. - It can be used together with the supervision software for the supervision of the installation. - It works with: - the load control offer, with the support of the RS 485/IP converter, or with the communication modules used with the measurement central unit; - the BUS/KNX offer through the lighting management KNX/IP gateway; - the BUS/SCS offer with the BMNE500 control unit; - the safety lighting offer, with the interface for the management of addressable blocks; - the fire alarm offer, with the use of the RS 485/IP converter. 0 4 00* Legrand Supervision Software: Single software for integrated supervision of the following Legrand systems: - KNX automation - SCS Lighting Management - Power meter With one single interface it is possible to: - Acquire a global vision of the different systems of the building - Manage run-time systems - Display alarms from the different systems Program timed actions 125 data points licence INFRASTRUCTURE 0 4 01* Legrand Supervision Software: Single software for integrated supervision of the following Legrand systems: - KNX automation - SCS Lighting Management - Power meter With one single interface it is possible to: - Acquire a global vision of the different systems of the building - Manage run-time systems - Display alarms from the different systems - Program timed actions 250 data points licence 0 4 02* Legrand Supervision Software: Single software for integrated supervision of the following Legrand systems: - KNX automation - SCS Lighting Management - Power meter With one single interface it is possible to: - Acquire a global vision of the different systems of the building - Manage run-time systems - Display alarms from the different systems - Program timed actions 500 data points licence 0 4 03* Legrand Supervision Software: Single software for integrated supervision of the following Legrand systems: - KNX automation - SCS Lighting Management - Power meter With one single interface it is possible to: - Acquire a global vision of the different systems of the building - Manage run-time systems - Display alarms from the different systems - Program timed actions 1000 data points licence 0 4 04* Legrand Supervision Software: Single software for integrated supervision of the following Legrand systems: - KNX automation - SCS Lighting Management - Power meter With one single interface it is possible to: - Acquire a global vision of the different systems of the building - Manage run-time systems - Display alarms from the different systems - Program timed actions 2000 data points licence * For the availability of the product, contact the BTicino commercial representative. NOTE: Neutral item KNX CATALOGUE 11

12 dimensional data

Contents 14-16 Dimensional data Control devices 14 Sensors 14 Modular controllers 15 False ceiling controllers and automation 16 Gateway and interfaces 16 Infrastructure devices 16 KNX CATALOGUE 13

DIMENSIONAL DATA CONTROL DEVICES 22,5 67,5 H4651KNX H4651KNX 22.5 HC/HD/HS4680KNX 22.5 HC/HD/HS4680KNX 25.3 25.3 2 modules 4 modules H4651KNX LN4651KNX HC/HD/HS4680KNX HC/HD/HS4680KNX L/N/NT4680KNX 22.5 43.8 22.5 22 43.8 25.3 H4651KNX L4651KNX HD/HC/HS4680KNX L/N/NT4680KNX LN4651KNX L/N/NT4680KNX 126 22 44 25.1 150 96 86 HD/HC/HS4657M3KNX HD/HC/HS4657M4KNX 0 4 31 SENSORS 124.9 80.1 124.9 100.2 121.1 0 489 18 0 489 19 88 84.2 46.6 146.3 143.5 96 96 51 43.8 47 47 47 22 44 25.3 25.1 47 LN4651KNX L/N/NT4680KNX 44 25.1 47 47 H4651KNX LN4651KNX L/N/NT4680KNX 43.8 22 44 25.1 47 47 0 489 20 0 489 21 HD/HC/HS4434KNX L/N/NT4434KNX 14

MODULAR CONTROLLERS 106 86 72 55 71.8 61.5 56 55 70 44 70 55 44 0 026 59 0 026 60 0 026 61 0 026 62 70 55 44 0 026 63 140 66 50 0 026 64 83.5 0 026 35 0 026 40 0 484 18 0 484 22 213 - + 83 66 50 A 2 DIN modules B C TABLE WITH DIN SIZES (mm) No. of A B C modules 1 17.5 82 66 2 35 82 66 3 52.5 82 66 4 70 82 66 5 87.5 82 66 6 105 82 66 7 122.5 82 66 8 140 82 66 9 157.5 82 66 10 175 82 66 12 210 82 66 KNX CATALOGUE 15

DIMENSIONAL DATA FALSE CEILING CONTROLLERS AND AUTOMATION 147 50 50 55 17.5 44 157 144 54 50 114 130.5 106 240 275 0 488 61-0 488 62-0 488 64-0 488 66 0 026 50 0 488 84 GATEWAY AND INTERFACES 66 36 50 86 70 89 55 0 026 34 0 035 43 42 42 11 8.5 105 55 44 0 026 55 0 484 20 0 484 21 INFRASTRUCTURE DEVICES 66 72 55 55 36 44 55 18 44 0 035 04 0 035 12 0 035 16 0 035 47 16

BTicino SpA Viale Borri, 231 21100 Varese - Italy www.bticino.com BTicino SpA reserves at any time the right to modify the contents of this booklet and to communicate, in any form and modality, the changes brought to the same. AD-EXKNX14C/GB - Version 10/2014