AND MEMBRANES ROOFING UNDERLAYS. www.fakro.com

Similar documents
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Asphalt Shingle Application Requirements

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Including. Rubershield-Pro. Breather Membrane

ROOFS, SNOW AND ICE DAMS

Ubiflex. Non-lead flashing system

SHINGLE APPLICATION GUIDE

Multi-layer Insulation Blanket for Roofs

PAAM COMMERCIAL PRIVATE LIMITED

Energy Company Obligation (ECO): Technical Monitoring Questions

Roofers Guide to Underslating Membranes

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Preventing Ice Dams on Roofs

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

Building Owners Guide to a Duro-Last System!

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

MONARPERM 600, MONARPERM PLUS AND MONARPERM TOP (COLD VENTILATED AND WARM NON-VENTILATED)

Sun-Activ - reflective SBS membrane. Sun-Activ - White reflective bituminous waterproofing membrane for Cool Roof

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

The Warm Edge for insulating glass

HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

WATERPROOFING OF WET ROOMS

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Condensation. Some Causes, Some Advice

EcoTouch Insulation with PureFiber Technology

DEFECTS IN SHEET ROOFING THAT IMITATES ROOF TILES AS A RESULT OF THEIR ANCHORAGE

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

Glass partitions SFB 3074

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

PROVIDING PROTECTION IN CONSTRUCTION Technical guide: roofs.

Window Sill Details for Effective Drainage of Water

Isola Steel Gutters Strength and design for extreme climate!

Tsawwassen BC Arena Before & After installation of the Low-E ceiling

G VYCOR DECK PROTECTOR. For longer lasting decks, install Grace Vycor Deck Protector. It s an easy add-on to your deck projects.

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

European Technical Assessment ETA-15/0028 of 23/02/2015

SANS FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/ / / /341

INSULATED PITCHED ROOFING

Pile Seal for insect screen

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

BLACK JACK ALL WEATHER ROOF COATING

Mold Preventing I nterior System

Providing protection in construction

G VYCOR DECK PROTECTOR

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

Product Data Sheet ROCKPANEL Rockclad

solutions & tips six Wise Energy Guide Building envelope solutions and simple tips AIR SEALING

Conservatory Roof Structural Information Guide

Mineral fibreglass insulation

ABSeam Panel Overview and Installation Instructions

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Renovating Your Basement

Athena is the name given to our assortment of electronic tapes. products of the very highest quality. These tapes both conduct and

19 Examples of Wall Insulation

Section Page Section Page

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

DENSO WATERPROOFING SYSTEMS

Weatherproofing Kit for Connectors and Antennas

Sealing & Bonding Sika solutions for Window Installation

Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Residential Roofing Guide

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

Polymeric membrane for roof waterproofing

Dealing with damp, condensation and mould growth in your home.

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

Wraptite THE AIRTIGHT AND VAPOUR PERMEABLE MEMBRANE

Technology at its best. Benefits

A few good reasons to have a conservatory. The conservatory structure

Housing Fact Sheets. Moisture Condensation at the Windows

Cl/SfB (13.9) a comprehensive. technical guide. to the specification of. vapour control layers. GROUP LTD

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Bituminous Sheet Flat Roofs: Their repair and maintenance

How to Install Hardwood Flooring Over a Sub Floor

Herringbone Pattern Flooring

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Conservatory warm roof conversion system

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

Selecting Energy-Efficient Windows

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

Your guide to home maintenance. Flat Roofs

Self-Stick Roofing Solutions

ROOF CONDENSATION: A COSTLY PROBLEM

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

Transcription:

AND MEMBRANES 010 ROOFING UNDERLAYS 1

HO DOES YOUR ROOF BREATHe? MEMBRANES THE WAY to A WARM AND DRY ROOF HO HO HO HO HO HO WATERTIGHTNESS The FAKRO Company offers a wide range of membranes and underlays designed to function as primary roofing and protection of insulation against moisture and dust. In order to retain premium quality of offered products, the FAKRO Company is continuously verifying the key parameters of underlays and membranes such as: tear resistance, nail shank tear resistance, watertightness, roll length and width, basis weight. This guarantees that the product distributed under FAKRO brand always retains its declared technical parameters. VAPOUR PERMEABILITY Quality control system Testing resistance to UV radiation Testing resistance to tearing

natur e working with ROOFING MEMBRANES A roofing membrane acts as an initial roofing layer. It improves tightness of the roof, protects insulation against moisture and constitutes an important element of insulation systems used in pitched roofs. Application of the roofing membrane in the roof structure brings many advantages. ENERGY EFFICIENCY Roofing membranes do not require any air gaps between themselves and insulation. Insulation shifted towards membrane allows for thicker insulating layer of the roof along the whole rafter height which improves roof lagging and ensures energy savings. High vapourpermeability and watertightness of the membranes guarantee that the insulating material remains dry and only as such it can ensure high insulating properties. Windproofness and no ventilation gap between insulation and membrane prevents extraction of heat from the insulating material and penetration of moisture contained in the air. EASE OF INSTALLATION No need for any ventilation gap above insulation considerably facilitates installation work. Easier membrane installation translates into time savings, lower costs and reduced risk of workmanship error. INCREASED ROOF LONGEVITY Thanks to high vapour permeability of membranes, excessive moisture is evaporated from insulation. HEALTHY MICROCLIMATE IN THE LOFT Membranes form a secondary line of protection against rain, snow, moisture and dust which penetrate through the primary roofing. This gives a guarantee that potential leaks, water from melting snow or condensation are conveyed outside the roof and do not permeate the insulation layer. WIDE APPLICATION RANGE Roofing membranes offered by FAKRO are highly resistant to temperature, thus they can be installed in a number of roof structures, even those covered with metal sheeting.

WHAT AND WHERE ON THE ROOF AND WALLS NONPERMEABLE UNDERLAY The nonpermeable roofing underlay is a material shielding insulation and roof structure from water vapour penetration from habitable spaces. It is laid between insulation and finishing elements most often gypsum cardboards. It constitutes a barrier for water vapour forming inside the building, protecting, at the same time, wooden elements of the roof structure and insulation against moisture. The nonpermeable underlay fulfils the function of an additional windproofing prevents heat losses as a result of free air circulation and roof draughts. BANDS FOR ROOFING UNDERLAYS AND MEMBRANES The correct installation of nonpermeable roofing underlays requires application of proper joining bands. It ensures correct functioning of the initial roofing layer and nonpermeable layer. Any sealing work and damage repair in membranes or underlays should be performed with the use of purposebuilt bands. 4

WHAT AND where HIGH VAPOUR PERMEABLE MEMBRANES The membrane is a primary roofing layer which improves roofing tightness. It solves the problems related to condensation water accumulating in insulation and roof structure. The membranes can be used as initial roofing of sloping roofs in case of both habitable and nonhabitable loft spaces, and in external walls as windproofing. Pictogram description Application internal Application external (roof, walls) Vapour permeability Watertightness LOW VAPOUR PERMEABILITY MEMBRANES The low vapour permeability membranes are products used as initial roofing in sloping roofs. Their basic task as an initial roofing layer is to seal the primary roofing and protect insulation fitted in the roof structure from moisture. Application of the low vapour permeable membrane as an initial roofing in case of buildings with habitable loft spaces necessitates the use of lower ventilation gaps between the membrane and insulating material in the roof structure. 5

L L N15 MEMBRANES WITH HIGH VAPOUR PERMABILITY The membranes are characterised by unique combination of such parameters as watertightness and water vapour diffusivity. High watertightness protects the roof structure from: seepage and water condensing under roofing wind driven precipitation High water vapour permeability offered by the membrane allows moving insulation towards the membrane surface without the need for any ventilation gaps in the roof or wall structures. This makes it possible to apply thicker layer of insulation which translates into energy savings. The membrane is laid directly onto rafters, insulation or sarking with turquoise printed side facing outwards L L technical parameters L L N15 basis weight [g/m] 90 95 115 number of layers 1500 g/m/4h 800 g/m/4h 0.008 0.00 0.004 CLASS W1 CLASS W1 CLASS W1 190 110 0 145 0 15 from 40 to 10 from40 to 95 from 40 to 10 4 100 g/m /4h vapour permeability [g/m /4h] vapour permeability coefficient Sd [m] water penetration resistance class before and after artificial ageing resistance to tearing lengthwise [N/5cm] crosswise [N/5cm] application temperature range [ C] UV radiation resistance [month] 8 C/85%RH Lyssy material 6 roll dimensions [m] 1.5 x 50 18 order processing time working days 8 C/85%RH Lyssy E packing [roll/pallet] possibility of use on full boarding C/85%RH Lyssy polypropylene flammability class 6 N15 no no yes

N5 n5 s4 s65 N5 S65 S4 technical parameters N5 S4 S65 basis weight [g/m] 15 155 165 4 100 g/m/4h 00 g/m/4h 0.004 0.00 number of layers 900 g/m /4h vapour permeability [g/m /4h] vapour permeability coefficient Sd [m] 8 C/85%RH Lyssy 0.007 water penetration resistance class before and after artificial ageing resistance to tearing lengthwise [N/5cm] crosswise [N/5cm] 50 170 possibility of use on full boarding 0 190 4 polypropylene flammability class roll dimensions [m] 60 80 from 40 to 10 material packing [roll/pallet] 8 C/85%RH Lyssy CLASS W1 application temperature range [ C] UV radiation resistance [month] 8 C/85%RH Lyssy E 6 5 5 1.5 x 50 yes 18 order processing time working days 7

LOW VAPOUR PERMEABILITY kf 96 silver kf 110 MEMBRANES The KF low permeability membrane has found its application as an initial roofing layer in building with habitable as well as nonhabitable loft spaces. The low permeability membrane proves to be a very effective insulation of walls in buildings of skeleton structure (wooden or metal). In buildings in which function and simple roof shapes do not require application of membranes offering high vapour permeability and, at the same time, high strength and low material costs play major role, the low vapour permeability membrane can be used. standard KF 110 KF 96 technical parameters basis weight [g/m] KF 96 SILVER KF 110 STANDARD 98 110 vapour permeability [g/m /4h] 0 head of water [mm] 10 water penetration resistance before and after artificial ageing tear resistance lengthwise [N/5cm] crosswise [N/5cm] UV radiation resistance [month] application temperature range [ C] 40 190 from 40 C to 80 C 1 flammability class F packing [roll/pallet] 50 roll dimensions [m] 1.5 x 50 18 order processing time working days 600 500 vapour permeability coefficient Sd [m] 8 CLASS W

NONPERMEABLE ROOFING UNDERLAYS The Termofol 90 nonpermeable underlay used in conjunction with high vapour permeability membranes makes it possible to retain proper climatic conditions within the habitable loft spaces. Termofol 90 provides very effective protection against moisture penetrating into insulation and, thanks to a thin layer of aluminium film used, it partially reflects the heat radiating from the loft. It improves effectiveness of heating, cutting energy consumption. Additional underlay reinforcement in the form of polypropylene netting adds to strength characteristics of the product. In order to ensure the possibility of reflecting thermal radiation it is necessary to construct at least cm high reflecting space. TERMOFOL technical parameters TERMOFOL 90 basis weight [g/m] 90 resistance to tearing lengthwise N/5cm crosswise N/5cm tear resistance lengthwise N/5cm crosswise N/5cm resistance to weather conditions (months) application temperature range [ C] vapour permeability coefficient Sd [m] flammability class termofol 90 90 0 10 40 50 from 40 C to 80 C >70 E packing [roll/pallet] 50 roll dimensions [m] 1.50 x 50 18 order processing time working days 9

EUROBAND w EUROBAND P BUTYLBAND EUROBAND BANDS FOR ROOFING MEMBRANES AND UNDERLAYS The bands offered by FAKRO are used for permanent joining, sealing and mending roofing membranes and nonpermeable underlays. They are also recommended for attaching membranes and underlays to structural elements, e.g. wood, wall or metal. ALUFIX EUROBAND W onesided adhesive band based on polypropylene cloth, 50mm wide. Intended use: joining together successive layers of membranes, repairing membranes attaching membranes to wood, plastic or metals EUROBAND P onesided adhesive band, 40mm wide. Intended use: sealing and insulating connection points between roofing membranes or underlays and roof structure eliminates the risk of water penetration to insulation and rafters through openings created by roofing nails or pliers BUTYLBAND butyl band with adhesive on both sides, 10mm wide. Intended use: attaching membranes and Termofol 90 underlay to walls, around chimneys and flanges over gutters, joining overlaps of membranes, low vapour permeability or nonpermeable underlays, joining materials where permanent connection flexibility and resistance to moisture and ageing is required. EUROBAND onesided butyl band, coated with aluminium film, 50mm thick Intended use: mending roofing membranes and underlays, sealing skylights and windows, sealing around chimneys. ALUFIX onesided butyl band, 75mm wide Intended use: sealing nonpermeable underlays joining overlaps of nonpermeable underlays mending nonpermeable underlays EUROBAND P EUROBAND W EUROBAND BUTYLBAND ALUFIX 10 L L N15 N5 S65 S4 TERMOFOL 90

EUROBAND W EUROBAND P band type onesided adhesive onesided adhesive carrier type polypropylene fibres nonabsorbent polyethylene foam acrylic rubberbased temperature resistance from 40 to 10 C from 0 to 80 C installation temperature from 18 to 5 C turquoise dark grey 50 mm x 5 m 40 mm x 0 m 4 rolls 1 rolls technical parameters adhesive colour roll dimensions packing [roll/cardboard] technical parameters BUTYLBAND EUROBAND ALUFIX band type twosided adhesive onesided adhesive onesided adhesive carrier type butyl butyl coated with aluminium film BOPP film coated with aluminium adhesive butyl butyl acrylic temperature resistance from 0 to 80 C from 0 to 80 C 100 C application temperature from 5 to 40 C from 5 to 40 C grey silver, grey silver 10 mm x 0 m 50 mm x 10 m 75 mm x 50 m 4 rolls 1 rolls 64 rolls colour roll dimensions packing [roll/cardboard] 11

FAKRO reserves the right to change specifications at any time. FM/1s/COM/06.010/F04E