Fluorescence Lifetime Imaging and Fluorescence Correlation for Laser Scanning Microscopes



Similar documents
Recording the Instrument Response Function of a Multiphoton FLIM System

Make Life Easier by Using Modern Features of the SPCM Software

Microsecond Decay FLIM: Combined Fluorescence and Phosphorescence Lifetime Imaging

TCSPC for FLIM and FRET in Microscopy

Molecular Spectroscopy

Zeiss 780 Training Notes

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

FRET Basics and Applications an EAMNET teaching module

Applications of confocal fluorescence microscopy in biological sciences

ZEISS Microscopy Course Catalog

Two-photon FCS Tutorial. Berland Lab Department of Physics Emory University

Fluorescent dyes for use with the

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Introduction to flow cytometry

Correlation Measurements by Advanced TCSPC Techniques

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Zecotek S Light Projection Network Marketing

Introduction APPLICATION NOTE

UNIVERSITY OF WROCŁAW

AxioCam HR The Camera that Challenges your Microscope

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Time-Correlated Single Photon Counting

NyONE - Cell imaging in a bird s eye view 4. NyONE...resolution matters! 8. Features & benefits 10. Fluorescence excitation channels 12

13C NMR Spectroscopy

Realization of a UV fisheye hyperspectral camera

Flow cytometry basics fluidics, optics, electronics...

FTIR Instrumentation

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

DNA Detection. Chapter 13

Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR

Single Photon Counting Module COUNT -Series

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. IV Femtosecond Measurements Combined With Near-Field Optical Microscopy - Artyom A.

A pretty picture, or a measurement? Retinal Imaging

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

Spectral Measurement Solutions for Industry and Research

Experiment #5: Qualitative Absorption Spectroscopy

Advances in scmos Camera Technology Benefit Bio Research

Confocal Fluorescence Microscopy

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Copyright by Mark Brandt, Ph.D. 12

FIBER-OPTIC MULTIPHOTON FLUORESCENCE SPECTROSCOPY FOR BIOSENSING AND IN VIVO FLOW CYTOMETRY

Leica TCS SP5 Confocal Laser Scanning Microscope User Guide 1. BASIC IMAGE ACQUISITION

Taking the Confusion out of Confocal Microscopy

Webex-based remote instrument control guide

Optical laser beam scanner lens relay system

Neuro imaging: looking with lasers in the brain

Fluorescence Microscopy for an NMR- Biosensor Project

Real-world applications of intense light matter interaction beyond the scope of classical micromachining.

Time-Correlated Single Photon Counting

A VERYbrief history of the confocal microscope 1950s

Z-Stacking and Z-Projection using a Scaffold-based 3D Cell Culture Model

Zeiss Axioimager M2 microscope for stereoscopic analysis.

A Digital Spectrometer Approach to Obtaining Multiple Time-Resolved Gamma-Ray. Spectra for Pulsed Spectroscopy. W. K. Warburton a

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

Ultraviolet Spectroscopy

DYNAMIC LIGHT SCATTERING COMMON TERMS DEFINED

PicoMaster. TCSPC Fluorescence Lifetime Spectrofluorometer. Explore the future

Fiber Optics: Fiber Basics

ZEISS T-SCAN Automated / COMET Automated 3D Digitizing - Laserscanning / Fringe Projection Automated solutions for efficient 3D data capture

Introduction to Flow Cytometry

Raman spectroscopy Lecture

Silicon Seminar. Optolinks and Off Detector Electronics in ATLAS Pixel Detector

Explaining Ellipse I 2 PL

Principles of Microscopy and Confocal and Fluorescence Microscopy

Raman Spectroscopy Basics

Improving Chromatic Dispersion and PMD Measurement Accuracy

Current equipment list Advanced Light Microscopy Unit (February 2015)

Designing and Manufacturing Femtoseconds Ultra-broadband Lasers: Proven, Hands-free Reliability

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

These particles have something in common

How To Use An Ionsonic Microscope

Time-domain measurement of fluorescence lifetime variation with ph.

High speed infrared camera for contactless temperature measurement on rotating tires

Chapter 10 Immunofluorescence

Physics 441/2: Transmission Electron Microscope

Introduction to Fourier Transform Infrared Spectrometry

ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution

A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine

Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

AN51 APPLICATION NOTE Revision 1

EUSIPCO

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

PMS-300 PMS-400 and PMS-400A 800 MHz Gated Photon Counters / Multiscalers

Application Note AN1

Module 13 : Measurements on Fiber Optic Systems

Cytell Cell Imaging System

Optical mesoscopy with a new giant lens. Gail McConnell, Johanna Tragardh, John Dempster & Brad Amos

Lecture 1: Basic Concepts on Absorption and Fluorescence

MCAL Spectrophotometry. Spectrophotometry

COMPENSATION MIT Flow Cytometry Core Facility

Flow Cytometry A Basic Overview

Characterizing Quantum Dots and Color Centers in Nanodiamonds as Single Emitters

A More Efficient Way to De-shelve 137 Ba +

Transcription:

Fluorescence Lifetime Imaging and Fluorescence Correlation for Laser Scanning Microscopes Direct approach to fluorescence resonance energy transfer (FRET) Probing cell parameters by environment-dependent lifetime Co-localisation experiments by combined FRET and fluorescence correlation spectroscopy (FCS) Separation of fluorophores by lifetime Four-dimensional TCSPC technique Superior time resolution Multi-wavelength capability Simultaneous FCS / FCCS and lifetime recording Ultra-high sensitivity Near-ideal counting efficiency Works at any scan rate of the microscope Lifetime images up to 1024 x 1024 pixels Steady state images up to 4096 x 4096 pixels 03 Lifetime, ns 12 CFP/YFP FRET 05 FRET Intensity 20 Becker & Hickl GmbH Nahmitzer Damm 30 12277 Berlin, Germany Tel +49 / 30 / 787 56 32 Fax +49 / 30 / 787 57 34 email: info@becker-hicklcom wwwbecker-hicklcom US Representative: Boston Electronics Corp tcspc@boseleccom wwwboseleccom UK Representative: Photonic Solutions PLC sales@psplccom wwwpsplccom SPC-830 TCSPC FLIM Module Covered by patents DE 43 39 784 and DE 43 39 787

Introducing a New Dimension into Laser Scanning Microscopy Fluorescence Lifetime When a dye molecule absorbs a photon it goes into an excited state from which it can return by the emission of a fluorescence photon, by converting the absorbed energy internally, or by transferring the energy to the environment, see figure below Laser Pulse Excited State Population e -t/ Emission + Internal Conversion e -t/ 0 Energy transferred to Environment Return of molecules from the excited state The probability that one of these effects occurs is independent of the time after the excitation If a large number of similar molecules with similar local environment is excited by a short laser pulse the fluorescence decay function is therefore single exponential As long as no energy is transferred to the environment the lifetime is the natural fluorescence lifetime, τ 0 which is a constant for a given molecule and refraction index of the solvent The fluorescence lifetime of the fluorophores commonly used in microscopy are of the order of a few ns Fluorescence Quenching If energy is transferred to the environment the actual fluorescence lifetime, τ, is less than the natural lifetime, τ 0 Therefore the lifetime of markers can be used as an additional probe technique in cells A wide variety of chromophores including CFP, GFP and YFP clearly show variations in their fluorescence lifetimes Although most of these effects are not investigated in detail yet there is probably a large potential for intelligent markers based on lifetime changes Resonance Energy Transfer A particularly efficient energy transfer process is fluorescence resonance energy transfer, or FRET FRET occurs if the molecules two different dyes are closely coupled and the emission band of one dye overlaps the absorption band of the other In this case the energy from the first dye, the donor, goes immediately into the second one, the acceptor Donor Laser Donor Acceptor Acceptor Absorption Emission Absorption Emission D D A A Wavelength Fluorescence Resonance Energy Transfer (FRET) The strong energy transfer results in an extremely efficient quenching of the donor fluorescence and, consequently, decrease of the donor lifetime Intensity Laser pulse Intensity Laser pulse -t/ e 0 -t/ e 0 unquenched lifetime e -t/ quenched donor FRET unquenched donor e -t/ quenching Fluorescence quenching For almost all dyes the energy transfer rate depends more or less on the concentration of ions, on the oxygen concentration, on the ph value or on the binding to proteins in a cell Therefore, specifically designed dyes can be used to probe the concentration of biological relevant ions such as Na +, Mg ++, or Ca ++, the oxygen concentration or the ph value inside a cell There is a direct relation between the lifetime and the quencher concentration Fluorescence markers used to reveal particular protein structures in cells often bind to a variety of slightly different targets Although this often does not cause significant changes in their spectral behaviour the lifetime can be clearly different due to different quenching efficiency Decrease of donor lifetime in case of FRET The most intriguing feature of FRET is that it works only over a distance shorter than a few nm Therefore, it can be used to probe the distance between different sub-units in the cell It is difficult to obtain quantitative FRET results from steady-state images The fluorescence intensity does not only depend on the FRET efficiency but also on the unknown concentration of the dyes Moreover, some of the acceptor molecules are excited directly, and the donor emission band extends into the acceptor emission Up to eight measurements at different excitation wavelength and in different emission wavelength bands are required to obtain calibrated FRET results from steady state data FRET results can also be obtained by measuring the donor fluorescence, then photobleaching the acceptor, and measuring the donor once more The FRET efficiency is then given by the ratio of the two donor images Although this procedure looks

reliable at first glance photobleaching products may induce damage in the cell, and in a living cell diffusion may replace a fraction of the photobleached acceptor molecules In lifetime data, however, FRET shows up as a dramatic decrease of the donor lifetime In practice the fluorescence decay function contains the fluorescence of quenched and of unquenched donor molecules and is therefore doubleexponential Intensity b quenched b e -t / FRET a unquenched e -t / 0 a Fluorescence decay components in FRET systems time Therefore, quantitative measurements require double exponential decay analysis that delivers the lifetimes, τ 0 and τ FRET, and the intensity factors, a and b, of the two decay components The relative numbers of quenched and unquenched molecules is given by the ratio of the two intensity components, b/a, while the average coupling efficiency of the FRET pairs is given by τ 0 / τ FRET In principle, both the relative numbers of quenched and unquenched molecules and the coupling efficiency can be derived from a single donor lifetime measurement The image below shows the FRET efficiency in an HEK cell containing CFP and YFP in different sub-units of the cell The ratio a/b is represented by the colour Separation of DNA stained with Hoechst 33342 and tubulin stained with Alexa 488 by the lifetimes of the two fluorophores Especially autofluorescence images of cells and tissue show a wide variety of fluorescence components with poorly defined, variable, and often unknown spectra When spectral unmixing fails the components can usually be distinguished by their different lifetimes The relative concentration of two components can be determined by double-exponential decay analysis Even if only a single exponential approximation, ie an average lifetime is used, the contrast in the fluorescence images can be considerably improved Moreover, changes in the relative concentration and the lifetime of autofluorescence components can possibly be used as diagnostic tools The figure below shows an autofluorescence lifetime image of human skin with lifetimes varying from 05 ns to 25 ns FRET in HEK cell containing CFP and YFP in different sub-units Colour represents FRET intensity b/a, blue to red corresponds to 05 to 20 Red indicates strong FRET Separation of Different Fluorophores The fluorescence lifetime can be used as an additional parameter to separate the fluorescence signals of fluorophores with similar or overlapping spectra The figure below shows a cell stained with Hoechst 33342 and Alexa 488 linking to the DNA and the tubulin, respectively The two fluorophores are clearly separated only by their different lifetimes Autofluorescence lifetime image of human skin, colour represents lifetime, Colour scale: blue to red = 05 ns to 25 ns Size about 60 um x 60 um Multi-Wavelength TCSPC FLIM The Becker & Hickl fluorescence lifetime imaging (FLIM) modules employ a novel multi-dimensional time-correlated single photon counting (TCSPC) technique in conjunction with a new analog-to-digital conversion principle The new technique records a full fluorescence decay curve for each pixel of the image, allows a time resolution down to a few 10 ps, has a near-ideal counting efficiency, works with the full scan rate of the microscope, and is able to record in several wavelength intervals simultaneously The TCSPC FLIM technique requires a laser scanning microscope with pulsed laser excitation and is typically used in multi-photon microscopes The principle of the technique is shown below At the input of the system are several photomultipliers detecting in different wavelength intervals At the typical count rate of a two-photon microscope it is very unlikely that several detectors detect a photon within the same laser pulse

period Therefore, the detector electronics combines the single photon pulses of all detectors into a common timing pulse line Simultaneously, the detector electronics delivers a digital signal that indicates in which of the detectors a particular photon was detected Electronics s from Laser from Microscope Router Channel Timing Start Stop Frame Sync Line Sync Pixel Clock Channel register CFD CFD Measurement TAC Counter Y Scanning Interface Counter X TCSPC Module ADC y x n t Channel / Wavelength channel 1 within decay curve channel 2 Location within scanning area channel 3 Multi-wavelength TCSPC lifetime imaging channel 4 The recording electronics consists of a time measurement channel, a scanning interface, a detector channel register, and a large histogram memory The time measurement channel contains the usual TCSPC building blocks (CFDs, TAC, ADC) in the reversed start-stop configuration For each photon, it determines the detection time (t) with respect to the next laser pulse The scanning interface is a system of counters which receive the scan control signals (frame sync, line sync and pixel clock) from the microscope It determines the current location (x and y) of the laser spot in the scanning area Synchronously with the detection of a photon, the detector channel number (n) for the current photon is read into the detector channel register If the light is split into different wavelength intervals in front of the detectors n represents the wavelength of the detected photon The obtained values for t, x, y and n are used to address the histogram memory in which the distribution of the photons over time, wavelength, and the image coordinates builds up The result can be interpreted as separate data blocks for the different wavelength intervals Each block can be interpreted as an image containing a full fluorescence decay curve in each pixel The data acquisition runs at any scanning speed of the microscope As many frames can be accumulated as necessary to collect enough photons Due to the synchronisation via the scan clock pulses, the regular zoom and image rotation functions of the microscope act automatically on the TCSPC recording and can be applied in the usual way It should be pointed out that the histogramming process does not use any time gating, detector multiplexing or wavelength scanning Therefore, the method yields a near perfect counting efficiency and a maximum signal to noise ratio for a given fluorescence intensity and acquisition time Due to the short dead time of the TCSPC imaging electronics (125 ns) there is virtually no loss of photons for count rates up to about 10 6 /s For comparison, living cells under twophoton excitation typically deliver count rates of some 10 4 /s, cells stained with very stable high efficiency fluorophores of a few 10 5 /s Combined Lifetime and FCS Recording Fluorescence Correlation Spectroscopy (FCS) exploits intensity fluctuations in the emission of a small number of excited molecules in a femtoliter sample volume The fluctuations are on a time scale from some 100 ns to several ms To record intensity changes such fast, the SPC-830 TCSPC FLIM modules has an FCS mode that records the information about each individual photon The entry for each photon contains the time of the photon within the fluorescence decay curve, the time from the start of the experiment, and the number of the detector that detected the photon The data structure is shown below ps time from TAC / ADC Laser FIFO Buffer Photon Laser resolution 25 ps of picoseconds Fluorescence decay curves Channel Det No Det No Det No Det No Readout Hard disk time from start of experiment Start of experiment Photons resolution 50 ns Autocorrelation of ns to seconds Fluorescence correlation spectra Simultaneous FCS / lifetime data acquisition For each detector an individual correlation spectrum and an individual fluorescence decay curve can be calculated Or, if the detectors are recording in different wavelength intervals, the signals from several chromophores can be crosscorrelated The advantage of the TCSPC FCS technique is that FCS, FCCS, and lifetime data are obtained from the same cell, from the same spot inside the cell, and at the same time Therefore lifetime and correlation data can directly be compared Options In general, the SPC-830 FLIM module works with a wide variety of microscopes FLIM detectors and cable sets are available for the Zeiss LSM 510 NLO, the Leica SP 2, the Biorad 1024 and Radiance 2100, the Olympus FV 300, and the Nikon PCM 2000 PMH-100 detector Cables to detector Scan Control Cable SPC-730 TCSPC Module Cable to laser FLIM upgrade kit with PMH-100 detector and interface cables

FLIM detectors for different budget, time resolution and detection efficiency are shown below The PMH-100 is a general purpose detector module with internal power supply and preamplifier The width of the instrument response function (IRF) is 150 ps The Hamamatsu H7442-40 is a detector with ultra-high sensitivity and an IRF width of 250 ps It is exceptionally suitable for FCS measurements The ultimate in time resolution is the Hamamatsu R3809U with 30 ps IRF width Overview of Features Superior Resolution The width of instrument response function of the fastest available detectors is about 30 ps The time channels of the TSCPC recording can be selected down to less than 1 ps This allows the application of standard fit and deconvolution techniques for lifetime analysis Single and double exponential decay functions can be resolved - with decay components down to less than 10 ps Multi-Wavelength Capability Up to four FLIM detection channels can be operated simultaneously in different wavelength intervals Compared to consecutive acquisition runs for different wavelength the overall radiation dose at the sample is substantially reduced Multi-wavelength operation does not only reduce photobleaching in general, it also reduces errors due accumulated photobleaching in consecutive acquisition runs FLIM detectors: Left to right, PMH-100, IFR width 150 ps, H7422, IRF width 250 ps, ultra-high sensitivity, R3809U, IRF width 30 ps, with preamplifiers For the LSM 510, the SP 2 and the Radiance 2100 FLIM detector modules with ready-to use optical adapters are available An R3809U and a PMH-100 detector module for the non-descanned output of the Zeiss LSM 510 is shown below Both modules contain a shutter for detector overload protection FLIM detectors for LSM 510 NDD output A shutter is used for overload protection For other microscopes detector assemblies with standard C- mount adapters are available Two dual-wavelength detection modules with shutters for overload protection are shown below General purpose dual wavelength detector assemblies with shutter and dichroic beamsplitter Left: R3809U, IRF width 30 ps Right: PMH-100, IRF width 150 ps Near Ideal Recording Efficiency - Every Photon Counts There is no time-gating, wavelength scanning or detector multiplexing Every photon counts - regardless in which of the PMTs it was detected This high recording efficiency is maintained even for short lifetimes - down of the order of the instrument response width And it does not substantially drop up to count rates of 10 6 photon per second The high efficiency allows to reduce the excitation power and, in turn, reduce photobleaching effects Crisp Images from Deep Tissue Layers Multi-photon imaging was originally developed because it allows to obtain images from deep tissue layers Because there is no substantial excitation outside the focus the multiphoton microscope delivers sharp images with depth resolution However, the localised excitation is only one half of the story Before and image is built up, the fluorescence light must get out of the sample - and on the way out it is heavily scattered At the surface it emerges from a fuzzy spot The reason that a multi-photon microscope delivers crisp images from deep tissue layers is that it collects the photons from a large sample area and then assigns them to the correct image coordinates Obviously, this works only for single channel detectors - but not with a camera acquiring an image of the sample surface Consequently, in scanning microscopes TCSPC lifetime imaging is superior to gated or modulated image intensifiers in terms of image quality High Pixel Resolution The SPC-830 TCSPC imaging module is able to acquire a single image as large as 1024x1024 pixels with 16 time channels per pixel Four images with 512x512 pixels and 16 time channels can be recorded simultaneously Four images with 256x256 pixels are recorded with 64 time channels

Steady State Photon Counting The SPC-830 module is flexible enough to be operated with only one time channel This turns the TCSPC microscope into an ultra-high sensitivity high resolution multiwavelength photon counting imager A single image up to 4096 x 4096 pixels can be recorded Four simultaneously acquired images can be as large as 2048 x 2048 pixels each Single Pixel Analysis Fluorescence decay data of a single pixel can be acquired if the scanning of the laser beam is stopped in a defined location Sequences of decay curves can be recorded with acquisition times of less than 1 ms per curve Combined lifetime and FCS / FCCS Capability An individual correlation spectrum and an individual fluorescence decay curve is calculated If the detectors are operated in different wavelength intervals, the signals from several chromophores can be cross-correlated The advantage of the TCSPC FCS technique is that FCS, FCCS, and lifetime data are obtained from the same cell, from the same spot inside the cell, and at the same time Sample-Limited Acquisition Due to its near-ideal counting efficiency TCSPC imaging gives the shortest possible acquisition time for a given count rate obtained from the sample and for a given lifetime accuracy Unfortunately that does not actually mean that the acquisition times are short For single exponential lifetime analysis a few 100 photons per pixel are sufficient For samples stained with highly stable and highly efficient fluorophores a single exponential lifetime image can be recorded within less than 10 s However, double or even triple exponential decay analysis requires much more photons Moreover, count rates as low as a few 10 4 photons per second are not unusual for samples of poor photostability To obtain high accuracy data from such samples acquisition times of the order of 10 to 20 minutes can be required It should be pointed out that the reason for the long acquisition time is not the TCSPC technique - the sample itself is the bottleneck It is an unique feature of the TCSPC imaging technique that it delivers accurate decay data under such odd conditions Wolfgang Becker, Axel Bergmann, Christoph Biskup, Thomas Zimmer, Nikolaj Klöcker, Klaus Benndorf, Multi-wavelength TCSPC lifetime imaging Proc SPIE 4620 (2002) 79-84 König, K, Femtosecond Laser Microscopy in Biomedicine Laser Opto 32 (2/2000) 40-45 Wolfgang Becker, Klaus Benndorf, Axel Bergmann, Christoph Biskup, Karsten König, Uday Tirplapur, Thomas Zimmer, FRET Measurements by TCSPC Laser Scanning Microscopy, Proc SPIE 4431 (2001) 94-98 W Becker, A Bergmann, K Koenig, U Tirlapur, Picosecond fluorescence lifetime microscopy by TCSPC imaging Proc SPIE 4262 (2001) 414-419 K Koenig, C Peuckert, I Riemann, U Wollina, Optical tomography of human skin with picosecond time resolution using intense near infrared femtosecond laser pulses, Proc SPIE 4620-36 Tirlapur, UK, König, K (2002) Targeted transfection by femtosecond laser Nature 418, 290-291 S Ameer-Beg, PR Barber, R Locke, RJ Hodgkiss, B Vojnovic, GM Tozer, J Wilson, Application of multiphoton steady state and lifetime imaging to mapping of tumor vascular architecture in vivo Proc SPIE 4620 (2002) 85-95 A Schönle, M Glatz, S W Hell, Four-dimensional multiphoton microscopy with time-correlated single photon counting Appl Optics 39 (2000) 6306-6311 A Rück, F Dolp, C Happ, R Steiner, M Beil, Fluorescence lifetime imaging (FLIM) using ps pulsed diode lasers in laser scanning microscopy Proc SPIE 4962-44 (2003) L Kelbauskas, W Dietel, Internalization of aggregated photosensitizers by tumor cells: Subcellular time-resolved fluorescence spectroscopy on derivates of pyropheophorbide-a ethers and chlorin e6 under femtosecond one- and two-photon excitation Photochem Photobiol 76 (2002) 686-694 Wolfgang Becker, Axel Bergmann, Christoph Biskup, Laimonas Kelbauskas, Thomas Zimmer, Nikolaj Klöcker, Klaus Benndorf, High resolution TCSPC lifetime imaging Proc SPIE 4963-30 (2003) Contact Becker & Hickl GmbH Nahmitzer Damm 30, 12277 Berlin, Germany wwwbecker-hicklcom Tel +49 / 30 / 787 56 32 Fax +49 / 30 / 787 57 34 Dr Wolfgang Becker Dr Axel Bergmann becker@becker-hicklcom bergmann@becker-hicklcom Literature SPC-134 through SPC-730 TCSPC Modules, Operating Manual and TCSPC Compendium Becker & Hickl GmbH, wwwbecker-hicklcom W Becker, A Bergmann, Lifetime Imaging Techniques for Optical Microscopy wwwbecker-hicklcom TCSPC Laser Scanning Microscopy - Upgrading laser scanning microscopes with the SPC-730 TCSPC lifetime imaging module, Becker & Hickl GmbH, wwwbecker-hicklcom Wolfgang Becker, Axel Bergmann, Assemblies for Picosecond Microscopy wwwbecker-hicklcom Wolfgang Becker, Axel Bergmann, Georg Weiss, Lifetime Imaging with the Zeiss LSM-510 Proc SPIE 4620 (2002) 30-35