TCSPC for FLIM and FRET in Microscopy
|
|
|
- Georgia Norton
- 9 years ago
- Views:
Transcription
1 Boston Electronics Corporation 91 Boylston Street, Brookline MA USA (800) or (617) fax (617) TCSPC for FLIM and FRET in Microscopy The Becker & Hickl S C-series Module Family PC Based Systems i n t e l l i g e n t measurement and control systems Becker & Hickl GmbH Nahmitzer Damm Berlin, Germany Tel Fax [email protected]
2 FLIM Upgrade Kits for Confocal Microscopes Fluorescence lifetime imaging with ps resolution Excitation by picosecond diode laser Confocal detection Simultaneous detection in several wavelength intervals Multi-dimensional TCSPC technique Excellent time-resolution and sensitivity Zoom and image rotation functions of microscope applicable Works at any scan rate Separation of fluorophores by lifetime Autofluorescence FRET experiments Imaging of ph, ion concentrations, or oxygen concentration The systems are based on a picosecond diode laser of 405 nm or 473 nm wavelength with high-efficiency single-mode fibre coupling, a single-, dual-, or multi-wavelength detector module, and BH s proprietary multi-dimensional TCSPC technique. The pulsed laser light is fed into the microscope via a standard single-mode optical fibre. A high speed detector assembly is attached to a suitable optical output of the scan head. Both directly coupled and fibre-coupled versions are available. A large variety of detector modules is available for single-wavelength, dualwavelength, or multispectral detection in 16 wavelength channels. The signals of all detector channels are recorded simultaneously by multidimensional TCSPC, resulting in excellent efficiency and time resolution. Typical applications are multi-spectral autofluorescence imaging of tissue, ph imaging in tissue, combined FLIM and SHG imaging, and investigation of protein interaction by FRET. The laser is a joint product of BH and LASOS TCSPC technique covered by patents DE and DE Becker & Hickl GmbH Nahmitzer Damm Berlin, Germany Tel Fax [email protected] LASOS Lasertechnik GmbH Carl-Zeiss-Promenade Jena, Germany Tel Fax [email protected] UK Representative: Photonic Solutions PLC Tel [email protected] US Representative: Boston Electronics Corp 91 Boylston Street, Brookline. Massachusetts USA Tel: (800) or (617) Fax: (617) tcspc@boselec com,
3 FLIM Upgrade Kits for Confocal Microscopes Computer Options TCSPC cards, to be placed in any Pentium computer Laptop-based systems, fully installed SPC-830 TCSPC module DCC-100 detector controller Detector Options PMC-100 / M-SHUT H / M-SHUT R3809U / M-SHUT R3809U / M-SHUT-DUAL PML-16 / MW-FLIM Cooled PMT Cooled GaAsP PMT Multichannel plate PMT Two multichannel plate PMTs Spectrograph and 16 channel multi-anode PMT IRF width 150 to 180 ps IRF width 300 to 350 ps IRF width < 30 ps Simultaneous detection Simultaneous detection in 16 wavelength channels For lifetimes down to 100 ps For lifetimes down to 200 ps For lifetimes down to 50 ps in two wavelength intervals For lifetimes down to 100 ps PMC-0: 340 to 650 nm 340 to 690 nm, ultra-high sensitivity R3809U-52: 340 to 650 nm R3809U-52: 340 to 650 nm PML-16-0: 340 to 650 nm PMC-1: 340 to 820 nm R3809U-50: 340 to 820 nm R3809U-50: 340 to 820 nm PML-16-1: 340 to 820 nm Other combinations: Please call bh Directly Supported Microscopes FLIM Data Analysis Manufacturer / Type Zeiss LSM 510 Zeiss LSM 510 META Leica SP2 Olympus FV1000 Biorad Radiance Jenlab Tau-Map Other Microscopes Remarks Fibre out required Fibre out required Complete FLIM systems available from Leica Fibre out or directly coupled detectors Fibre out required Available from Jenlab please call bh SPCImage Data Analysis Single and multi exponential decay analysis Lifetime in pixels displayed as colour Lifetime distribution FRET intensity by doubleexponential analysis of donor decay function For more information please download or call for SPC-134 through SPC-830 TCSPC modules, Manual and TCSPC compendium Upgrading TCSPC laser scanning microscopes with the SPC-730 and SPC-830 TCSPC imaging modules W. Becker, A. Bergmann, Lifetime imaging techniques for optical microscopy W. Becker, A. Bergmann, Detector assemblies for picosecond microscopy DCC-100 manual SPCImage manual SPC-830, DCC-100, PMC-100, MW-FLIM, Simple-Tau data sheets Becker & Hickl GmbH Nahmitzer Damm Berlin, Germany Tel Fax [email protected] LASOS Lasertechnik GmbH Carl-Zeiss-Promenade Jena, Germany Tel Fax [email protected] UK Representative: Photonic Solutions PLC Tel [email protected] US Representative: Boston Electronics Corp 91 Boylston Street, Brookline. Massachusetts USA Tel: (800) or (617) Fax: (617) tcspc@boselec com,
4 Febr 2003 Printer HP4500PS TCVGBH1.DOC Lifetime Imaging Techniques for Optical Microscopy Wolfgang Becker, Axel Bergmann Becker & Hickl GmbH, Berlin, 1
5 Contents Introduction...3 Biological Applications of Lifetime Techniques...3 Fluorescence Quenching...3 Resonance Energy Transfer...4 Separation of Different Chromophores...5 Diffusion in Cells...5 Microscopy Techniques...6 Wide-Field Fluorescence Microscopy...6 Laser Scanning Microscopy...6 Optical Near-Field Microscopy...7 Light Sources...8 Titanium-Sapphire Lasers...8 Frequency Doubled Titanium-Sapphire Lasers...8 Fibre Lasers...8 Pulsed Diode Lasers...8 Modulated CW Lasers...9 Mode-locked CW Lasers...9 Pulse Pickers and Cavity Dumpers...9 Detectors...9 Photomultiplier Tubes (PMTs)...9 Image intensifiers...11 Avalanche photodiodes...12 Cornerstones of Fluorescence Lifetime Imaging...13 Time Resolution...13 Signal-to-Noise Ratio...13 Detection efficiency...13 Recording efficiency...14 Sample Saturation...14 Photobleaching...14 Signal Processing Techniques...15 Gated Image Intensifiers...15 Modulation Techniques...17 Single Channel Modulation Techniques...18 Modulated Image Intensifiers...20 Gated Photon Counters...23 Time-Correlated Single Photon Counting (TCSPC)...26 TCSPC Imaging...27 Multi Wavelength TCSPC Imaging...29 Features of the TCSPC imaging techniques...32 Other TCSPC Techniques...35 Application of TCSPC to diffusion in cells...35 TCSPC Wide Field Imaging...35 Comparison of Signal Processing Techniques...36 Summary...37 References
6 Introduction Since their broad introduction in the early 90s confocal and two-photon laser scanning microscopes have initiated a breakthrough in biomedical imaging [1-5]. The applicability of multi-photon excitation, the optical sectioning capability and the superior contrast of these instruments make them an ideal choice for fluorescence imaging of biological samples. However, the fluorescence of organic molecules is not only characterised by the emission spectrum, it has also a characteristic lifetime. Any energy transfer between an excited molecule and its environment in a predictable way changes the fluorescence lifetime. Since the lifetime does not depend on the concentration of the chromophore fluorescence lifetime imaging is a direct approach to all effects that involve energy transfer [6-10]. Typical examples are the mapping of cell parameters such as ph, ion concentrations or oxygen saturation by fluorescence quenching, or fluorescence resonance energy transfer (FRET) [6,7,8] between different chromophores in the cell. Furthermore, combined intensity / lifetime imaging is a powerful tool to distinguish between different fluorescence markers in multi-stained samples and between different natural fluorophores of the cells themselves. These components often have ill-defined fluorescence spectra but are clearly distinguished by their fluorescence lifetime [70]. Fluorescence lifetime measurements require a pulsed or modulated excitation source, a sufficiently fast detector and a suitable recording electronics. This article gives an overview about applicable time-resolved signal recording techniques and their benefits and drawbacks. Biological Applications of Lifetime Techniques When a dye molecule absorbs a photon it goes into an excited state from which it can return by the emission of a fluorescence photon, by converting the absorbed energy internally, or by transferring the energy to the environment (fig. 1) [6,9,10]. The probability that one of these effects occurs is independent of the time after the excitation. If a large number of similar molecules with similar local environment is excited by a short laser pulse the fluorescence decay function is therefore single exponential. As long as no energy is transferred to the environment the lifetime is the natural fluorescence lifetime, τ 0 which is a constant for a given molecule and refraction index of the solvent. The fluorescence decay times of the fluorophores commonly used in microscopy are of the order of a few ns. Fluorescence Quenching If energy is transferred to the environment the actual fluorescence lifetime, τ, is less than the natural lifetime, τ 0. For almost all dyes the energy transfer rate depends more or less on the concentration of ions, on the oxygen concentration, on the ph value or on the binding to proteins in a cell [6,9,10]. Therefore, specifically designed dyes can be used to probe the concentration of biological relevant ions such as Na +, Mg ++, or Ca ++, the oxygen concentration or the ph value inside a cell. There is a direct relation between the lifetime and the quencher Excited State Population Laser e -t/ Emission + Internal Conversion e -t/ 0 Energy transferred to Environment Time Fig. 1: Return of molecules from the excited state Intensity Laser e -t/ -t/ e 0 unquenched lifetime quenching Fig. 2: Fluorescence quenching Time 3
7 concentration, fig. 2. Fluorescence markers used to reveal particular protein structures in cells often bind to a variety of slightly different targets. Although this often does not cause significant changes in their spectral behaviour the lifetime can be clearly different due to different quenching efficiency. Therefore the lifetime of markers can be used as an additional probe technique in cells [11, 12]. A wide variety of chromophores including CFP, GFP and YFP clearly show variations in their fluorescence lifetimes. Although most of these effects are not investigated in detail yet there is probably a large potential for intelligent markers based on lifetime changes. Fluorescence can be almost entirely quenched in aggregates of fluorophore molecules. Lifetimes as short as 20 ps have been found. The fast relaxation is often considered unfavourable for photodynamic therapy applications. However, if the aggregates monomerise inside a tumor cell the effect can be of particular interest [52]. Resonance Energy Transfer A particularly efficient energy transfer process is fluorescence resonance energy transfer, or FRET. FRET occurs if two different dyes are present with the emission band of one dye overlapping the absorption band of the other [6,7,8]. In this case the energy from the first dye, the donor, goes immediately into the second one, the acceptor. This results in an extremely efficient quenching of the donor fluorescence and, consequently, decrease of the donor lifetime, see fig. 3. Intensity Intensity Laser Donor Donor Acceptor Acceptor Absorption Emission Absorption Emission Laser D D A A Wavelength Emission -t/ e quenched donor -t/ e 0 FRET unquenched donor Time 4 Fig. 3: Fluorescence Resonance Energy Transfer (FRET) FRET works only over a distance shorter than a few nm. Therefore, it can be used to probe the distance between different subunits in the cell. It is difficult to obtain quantitative FRET results from steady-state images. The fluorescence intensity does not only depend on the FRET efficiency but also on the unknown concentration of the dyes. Moreover, some of the acceptor molecules are excited directly, and the donor emission band extends into the acceptor emission. Up to eight measurements at different excitation wavelength and in different emission wavelength bands are required to obtain calibrated FRET results from steady state data [4,5,7]. FRET results can also be obtained by measuring the donor fluorescence, then photobleaching the acceptor, and measuring the donor once more. The FRET efficiency is given by the ratio of the two donor images. Although this procedure looks reliable at first glance photobleaching products may induce damage in the cell, and in a living cell diffusion may replace a part of the photobleached acceptor molecules. In lifetime data, however, FRET shows up as a dramatical decrease of the donor lifetime [6,8,68,72]. The fluorescence decay functions contain the fluorescence of quenched and of unquenched donor Intensity b a quenched b e -t / FRET unquenched -t / 0 a e time Fig. 4: Fluorescence decay components in FRET systems
8 molecules and are therefore double-exponential, fig. 4. Qualitative FRET results can be obtained from the lifetime of a single exponential approximation of the decay curve. Quantitative measurements require double exponential decay analysis that delivers the lifetimes, τ 0 and τ FRET, and the intensity factors, a and b, of the two decay components [68,72]. The relative numbers of quenched and unquenched molecules is given by the ratio of the two intensity components, b/a, while the average coupling efficiency of the FRET pairs is given by τ 0 / τ FRET. In principle, both the ratio of quenched and unquenched molecules and the coupling efficiency can be derived from a single donor lifetime measurement. Separation of Different Chromophores Steady-state multi-wavelength techniques have been developed that efficiently separate different fluorescence markers by unmixing their fluorescence spectra [13]. However, not all marker combinations can efficiently be resolved. Even the well known GFP and YFP are difficult to unmix. Autofluorescence images of cells and tissue show a wide variety of fluorescence components with ill-defined, variable, and often unknown spectra. When spectral unmixing fails the components can usually be distinguished by their different lifetimes [70,75]. The relative concentration of two components can be determined by double-exponential decay analysis. Even if only a single exponential approximation, i.e. an average lifetime is measured, the contrast in the fluorescence images can be considerably improved. [70,75]. Moreover, changes in the relative concentration and the lifetime of autofluorescence components can possibly be used as diagnostic tools. Significant progress can be expected from combining spectral unmixing and lifetime analysis. Recording of time- and wavelength resolved data is technically possible by TCSPC techniques (see Multi Wavelength TCSPC Imaging ). Combining the two methods requires to develop suitable data analysis software. Diffusion in Cells Diffusion time constants in cells are usually in the ms range and below. They are usually determined by fluorescence correlation (FCS) techniques [14,15,16]. The problem is that the correlation technique is a single point measurement. Moreover, the measurement is usually not done in the same setup as the cell imaging. This makes it difficult to identify the measured spot in a particular cell with sufficient accuracy. Basically the photon counting techniques used for lifetime measurement are able to run a combined FCS and lifetime measurement at a single, well defined point of the sample. This could not only help to solve the positioning problem but also to identify single marker molecules [17] and to reveal conformational changes of the diffusing marker/protein clusters [18]. Although appropriate photon counters are available [63] no combined FLIM / FCS setup has become known yet. 5
9 Microscopy Techniques Wide-Field Fluorescence Microscopy As in any traditional microscope, the sample is uniformly illuminated by the excitation light. The image is detected by a CCD camera (fig. 5). To obtain time resolution in a wide-field setup the excitation light is pulsed or modulated and a gain modulated or gated intensified CCD camera is used [19,20,21,23]. The restriction to a special detection technique with sub-optimal efficiency is a drawback of wide-field imaging. Furthermore, wide-field imaging does not have the inherent depth resolution of the scanning techniques (see section below). However, there is a remarkable technique to obtain 3D images in whole-field microscopes [22], and a time-resolved solution with a gated CCD camera is described in [23]. The most severe drawback of the wide-field technique is that it cannot be used for two-photon excitation - a technique that allows deep tissue imaging in scanning microscopes. Gated or modulated intensified CCD Camera Dichroic Mirror Excited Objective Lens Sample Pulsed or modulated Light Source Fig. 5: Whole-field fluorescence lifetime imaging A benefit of wide-field imaging is that it probably causes less photobleaching than the scanning techniques. Provided the same number of detected photons and the same detection efficiency, the overall excitation dose for wide-field imaging is the same as for the scanning techniques described below. However, the excitation density is much smaller because the light is not focused. Since the increase of photobleaching with the power is nonlinear it should be expected that wide field imaging is less affected by photobleaching than scanning techniques. Wide field techniques are therefore superior for time-lapse imaging, i.e. for recording sequences of images in millisecond intervals. For fluorescence lifetime imaging the situation may be less favourable because the detection techniques applicable for wide-field imaging are not the most efficient ones [39]. Laser Scanning Microscopy The general optical principle of a laser scanning microscope [1,2] is shown in fig. 6. Pinhole The laser is fed into the optical path via a dichroic mirror and focused into the sample by the microscope objective lens. In the traditional Detector confocal setup used for one-photon excitation (fig. 6, left) the light from the sample goes back through the objective lens, through the scanner, is diverted by a dichroic mirror and goes through a pinhole in the upper image plane of Excited the objective lens. Light from outside the focal plane is not focused into the pinhole and therefore substantially suppressed. X-Y imaging is achieved by optically scanning the laser spot over the sample, Z imaging (optical sectioning) is possible by moving the sample or the microscope up and down. With a fs Ti:Sa laser the sample can be excited by two-photon absorption [3,54,78]. Excitation occurs only in the focus, so that no pinhole is required to reject light from outside the focal plane. 6 Laser Dichroic Mirror Scanner Objective Lens Sample One-Photon Excitation Detector Pinhole Detector Excited Laser fs Pulses Dichroic Mirror Scanner Dichroic Mirror Objective Lens Sample Two-Photon Excitation Fig. 6: General setup of a laser scanning microscope
10 Therefore, the fluorescence light need not be fed back through the scanner and through the pinhole. It can be diverted by a dichroic mirror directly behind the microscope objective. This setup is called non-descanned detection in contrast to the descanned detection shown above. Two-photon excitation in conjunction with non-descanned detection can be used to image tissue layers as deep as 500 µm. Since the scattering and the absorption at the wavelength of the twophoton excitation are small the laser beam penetrates through relatively thick tissue. Even if there is some loss on the way through the tissue it can easily compensated by increasing the laser power. The increased power does not cause much photodamage because the power density outside the focus is small. However, as long as there are enough ballistic (non-scattered) excitation photons in the focus the fluorescence is excited. Of course, the fluorescence photons are heavily scattered on their way out of the tissue and therefore emerge from a relatively large area of the sample surface which is out of the focus of the objective. However, for non-descanned detection there is no need to focus the fluorescence light anywhere. Therefore the fluorescence photons can be efficiently transferred to the detector. It is sometimes believed that lifetime imaging is somehow connected to two-photon excitation. This is, of course, not correct. Depending on the signal processing technique used, lifetime imaging requires a pulsed or modulated laser. Although a Ti:Sa laser is the ideal source lifetime imaging is possible with the frequency doubled Ti:Sa laser, with pulsed diode lasers, or with modulated CW lasers. Optical Near-Field Microscopy The optical near-field microscope (SNOM or NSOM) combines the principles of the atomic force microscope and the laser scanning microscope [24-28]. A sharp tip is scanned over the sample and kept in a distance comparable to the diameter of a single molecule. The tip can be the end of a tapered fibre through which the laser is fed to the sample (fig. 7, left). Or, the tip is illuminated by focusing the laser through the microscope objective on it and the evanescent field at the tip is used to probe the sample structure (fig. 7, right). In any case, the fluorescence photons are collected through the microscope objective. lever Fibre Laser lever scan Sample scan Sample Detection Microscope Objective Detection Microscope Objective Laser Fig. 7: Optical near-field microscope The optical near-field microscope reaches a resolution of a few 10 nm, i.e. about 10 times less than the laser scanning microscope. Imaging cells with this technique is difficult and possibly restricted to special cases [27,28]. The realm of the optical near-field microscope are certainly applications where fluorescing molecules or nano-particles are fixed on a flat substrate. Generally, the SNOM principle can be combined with flourescence lifetime imaging in the same way as the normal laser scanning microscope. Since only a small number of photons can be obtained from the extremely small sample volume photon counting techniquesare used to obtain lifetime information [78]. The problem to be expected is that the proximity of the tip changes the 7
11 fluorescence lifetime of the sample. Whether this effect makes lifetime imaging in a SNOM useless or whether it can be exploited for completely new techniques is hard to say. Light Sources Depending on the signal processing technique used, fluorescence lifetime imaging requires either a pulsed excitation source with a repetition rate in the MHz range or a modulated light source with a possible variable modulation frequency of 50 MHz to 1 GHz and a near perfect modulation depth. Titanium-Sapphire Lasers The ultimate solution is the femtosecond Ti:Sa laser. These lasers deliver pulses with 70 to 80 MHz repetition rate, 80 to 200 fs pulse width and up to several Watts average power. The wavelength is in the NIR from 780 nm to 950 nm. To excite the sample which usually absorbs below 500 nm, simultaneous two photon excitation is used. Due to the short pulse width and the high energy density in the focus of the microscope the two-photon process works very efficiently. Therefore the traditional frequency doubling of the Ti:Sa radiation is not often used for laser scanning microscopes. Frequency Doubled Titanium-Sapphire Lasers Frequency doubled titanium-sapphire lasers can be used to excite the sample via the traditional onephoton absorption. Frequency doubling is achieved by a nonlinear crystal. The output power is in the mw range. Less than 50µW are required to excite a typical sample so that the available power is by far sufficient. Whether one-photon or two-photon excitation gives less photobleaching is still under discussion. In a some cases considerably higher count rates and less photodamage for onephoton excitation were reported [72]. Fibre Lasers Another useful excitation source are fibre lasers. Fibre lasers are available for a wavelength of 780 nm and deliver pulses as short as 100 to 180 fs [29]. The average power is 10 to 20 mw. This is less than for the Ti:Sa laser but still sufficient for two-photon excitation. As a rule of thumb, the maximum useful power for biological samples and fs NIR excitation is 5 to 10 mw. A higher power kills the cells or cooks the sample. The benefit of the fibre laser is the small size, the high reliability and a lower price compared to the Ti:Sa laser. The drawback of the fibre laser is that it is not tuneable. Pulsed Diode Lasers A reasonable cost solution for one-photon excitation are pulsed diode lasers which are available for the NUV, blue, red, and near-infrared range [30-32]. These lasers deliver pulses with 40 to 400 ps duration and up to 80 MHz repetition rate. The average power is up to a few mw. However, the pulse width increases with the power. For pulses shorter than 100 ps the average power is of the order of a few 100 µw. Fig. 8 shows the typical pulse shape of a 405 nm picosecond diode laser. Pulsing diodes with less than 100ps width requires special driving techniques that are not commonly available. However, pulses as narrow as 300 ps from red diodes can easily be obtained by connecting a commercially available pulse generator to a bare laser diode. 8 Fig. 8: Pulse shape of a blue diode laser. BDL- 405, recorded with R3809U MCP and SPC-830 TCSPC module. FWHM is 80 ps.
12 It has been shown that diode lasers can be used for time-resolved microscopy with good results [33, 33a]. Unfortunately the beam quality of diode lasers is not very good. Therefore it can be difficult to obtain a diffraction-limited resolution. However, if only the central part of the beam is used, the result can be quite acceptable. Discarding a large fraction of the beam causes a considerable loss of power. This loss is, however, not substantial because 50 µw in the focal plane are sufficient to excite the sample. Modulated CW Lasers For signal processing techniques based on phase measurement of modulated signals CW Ar+ and HeNe lasers in conjunction with an acousto-optical modulator can be used. However, care must be taken to avoid any crosstalk of the modulation frequency into the detection system. The smallest amount of crosstalk makes an accurate phase measurement impossible. Using modulated CW lasers in conjunction with photon counting techniques is not recommended. These techniques require pulses rather than sinewave signals. Acousto-optical modulators are resonance systems unable to deliver sufficiently short pulses with high on/off ratio. Mode-locked CW Lasers Ar+ lasers can be actively mode-locked. By introducing a modulator into the laser cavity pulses as short as 100 ps with 80 to 120 MHz repetition rate are obtained. The pulses can be used directly or to pump a jet-stream dye laser that delivers ps pulses at a wavelength tuneable from 500 to 600 nm. Although the light from these lasers can be used for fluorescence excitation [65] the systems are often unstable and require permanent maintenance, checking and re-adjustment. We strongly discourage to use these lasers as excitation sources for time-resolved microscopy. Pulse Pickers and Cavity Dumpers Pulse pickers and cavity dumpers are used to obtain a lower repetition rate from lasers running at a high, fixed repetition rate. For fluorescence measurements they are sometimes used to measure lifetimes longer than the original period of the laser. The problem of the devices is the poor on-off ratio and the electrical noise they often produce. It is by far better to take some incomplete decay into regard in the data analysis than to cope with electrical noise and satellite pulses. Furthermore, a low repetition rate reduces the useful count rate in photon counting setups and possibly increases photobleaching. Don t use pulse pickers if they are not absolutely necessary. Detectors Photomultiplier Tubes (PMTs) The most common detectors for low level detection of light are photomultiplier tubes. A conventional photomultiplier tube (PMT) is a vacuum device which contains a photocathode, a number of dynodes (amplifying stages) and Photoan anode which delivers the output signal (fig. 9). Cathode D2 D1 D3 D4 D6 D5 D7 D8 Anode The operating voltage builds up an electrical field that accelerates the electrons from the photocathode to the first Fig. 9 Principle of a conventional PMT dynode D1, from D1 to D2, further to the next dynodes, and from D8 to the anode. When a photoelectron emitted from the photocathode hits D1 it releases several secondary electrons. The same happens for the electrons emitted by D1 when they hit D2. The overall gain reaches values of 10 6 to The secondary emission at the dynodes is very fast, therefore the secondary electrons resulting from one photoelectron arrive at the anode within a few 9
13 ns or less. Due to the high gain and the short response a single photoelectron yields a easily detectable current pulse at the anode. A similar gain effect is achieved in the channel plate of a microchannel PMT, fig. 10. The channel plate consists of millions of narrow parallel channels. The channels have a diameter below 10 µm and are coated with a conductive material. When a high voltage is applied across the plate the walls of the channels act as secondary emission targets. With two plates in series, a gain of the order of 10 6 is achieved. MCP PMTs deliver extremely fast pulses with low transit time jitter. Cathode Channel Plate Anode Photo Electron Channel Plate Electrical Field Fig. 10 Multichannel PMT Electrons to Anode There are two parameters that characterise the time resolution of a photomultiplier - the Single Electron Response, SER, and the Transit Time Spread, TTS. The SER is the output pulse for the detection of a single photon. The width of the SER limits the resolution of a PMT when it is used as a linear detector, i.e. a oscilloscope of fast digitizer. Some typical SER shapes for PMTs are shown in fig. 11. Iout 1ns/div 1ns/div 1ns/div Standard PMT (R928) Fast PMT (R5600, H5783) MCP-PMT (R3809U) Fig. 11: Single Electron Response (SER) for typical PMTs For photon counting applications the resolution is not limited by the width of the single electron response. For these techniques only the Transit Time Spread (TTS), i.e. the uncertainty of the delay between the photon detection and the output pulse is important. The TTS can be 10 times smaller than the width of the SER - a serious argument to use photon counting techniques in conjunction with photomultipliers. Due to the random nature of the detector gain, the pulse amplitude is not stable but varies from pulse to pulse. The pulse height distribution can be very broad, up to 1:5 to 1:10. Fig. 12 (right) shows the SER pulses of an R5600 PMT. The pulse height jitter introduces an additional noise factor into all measurements that use the PMT as a linear detector. The signal-tonoise ratio of photon counting measurements is not - or almost not - impaired by the pulse height jitter. If a PMT is operated near its full gain the peak current of the SER pulses is of the order of a few ma. This is much more than the allowed continuous output current. Consequently, for high repetition rate signals or steady state operation the PMT delivers a train of random pulses rather than a continuous signal. Because each pulse represents the detection of an individual photon the pulse density - not the pulse amplitude - is a measure for the light intensity at the cathode of the PMT. Obviously, the pulse Fig. 12: Amplitude jitter of SER pulses (R5600) 10
14 density is measured best by counting the PMT pulses within subsequent time intervals. Therefore, the application of photon counting techniques is the logical consequence of the high gain and the high speed of photomultipliers. The efficiency, i.e. the probability that a particular photon causes a pulse at the output of the PMT, depends on the efficiency of the photocathode. Unfortunately the sensitivity S of a photocathode is usually not given in units of quantum efficiency but in ma of photocurrent per Watt incident power. The quantum efficiency QE is h c S W m QE = S ---- = e λ λ A The efficiency for the commonly used photocathodes is shown in fig. 13 (right). The QE of the conventional bialkali and multialkali cathodes reaches 20 to 25 % between 400 and 500 nm. The recently developed GaAsP cathode reaches 45 %. The GaAs cathode has an improved red sensitivity and is a good replacement for the multialkali above 600 nm. Sensitivity 1000 ma/w Generally, there is no significant difference between the efficiency of similar photocathodes in different PMTs and from different manufacturers. The differences are of the same order as the variation between Wavelength nm different tube of the same type. Reflection type cathodes are a bit more efficient than Fig. 13: Sensitivity of different photocathodes [34] transmission type photocathodes. However, reflection type photocathodes have non-uniform photoelectron transit times to the dynode system and therefore cannot be used in ultra-fast PMTs. A good overview about the characteristics of PMTs is given in [34] and [79] GaAsP bia kali GaAs multialkali QE=0.5 QE=0.2 QE=0.1 Image intensifiers Image intensifiers are vacuum devices consisting of a photocathode, an acceleration and/or multiplication system for the photoelectrons, and a two-dimensional image detection system. First generation systems used a electron-optical imaging system that accelerates the photoelectrons to an energy of some kev and sends them to a fluorescent screen. The image from the screen was detected by a traditional camera or later with a CCD camera. First generation devices had a relatively low gain and strong image distortions. -HV Photocathode Multichannel Plate Fluorescence Screen CCD Camera Fig. 14: Intensified CCD camera 11
15 Second generation image intensifiers use multichannel plates for electron multiplication (fig. 14). One plate gives a typical multiplication factor of 1000 so that a gain of 10 6 can be achieved by two plates in series. The CCD chip can be placed inside the tube to detect the electrons directly. These EBD CCDs (Electron Bombarded CCDs) give higher gain than a CCD behind a fluorescent screen. Gating of an image intensifier can be accomplished by a grid behind the photocathode. Gain modulation can also be achieved by modulating the voltage between the cathode and the channel plate or the voltage across the multichannel plate. In general, image intensifiers use the same photocathodes as photomultiplier tubes. Therefore, the detection efficiency is approximately the same. There can, however, be an appreciable loss of photons or signal-to-noise ratio due to gating or modulating. Avalanche photodiodes Avalanche photodiodes (APDs) use a multiplication effect due to a strong electric field in a semiconductor structure (fig. 15). For use as a linear detector, a gain factor of the order of 100 can be achieved. However, cooled avalanche photodiodes can be used to detect single photons if they are operated close to or slightly above the breakdown voltage. The generated electron-hole pairs initiate an avalanche breakdown in the diode. Active or passive quenching circuits must be used to restore normal operation after each photon [36]. Therefore, a single photon avalanche photodiode (SPAPD) can only be used for photon counting. The advantage of an APD is the high quantum efficiency that can reach 90% in the near infrared. Single photon avalanche photodiode (SPAPD) modules are available from Perkin Elmer [35]. Although a resolution as fast as 20 ps has been reported for especially manufactured SPAPDs [36] the time resolution of these modules is in the order of 300 to 800 ps and depends on the count rate. This makes them less useful for lifetime measurements. SPAPDs are, however, excellently suited for fluorescence correlation measurements which do not require sub-ns resolution. 200V Photon Quenching Circuit Avalanche Output Fig. 15: Single Photon Avalanche Photodiode (SPAPD) 12
16 Cornerstones of Fluorescence Lifetime Imaging Time Resolution The lifetimes of highly efficient fluorescence markers are typically in the region of a few ns. However, these dyes are selected for high quantum yield. Lifetimes of less efficient chromophores can easily be below 100 ps. Quenching effects can reduce the lifetime down to a few 10 ps, and the lifetime of the quenched donor fluorescence in FRET experiments is in the order of 100 to 300 ps. Therefore, a good lifetime system should resolve fluorescence decay functions down to the order of 10 ps. The fluorescence decay curves of in biological samples are often multi-exponential. There can be several chromophores in the same part of a cell, a single chromophore can be quenched witch nonuniform efficiency, or there can be quenched and unquenched molecules in the same part of the cell. Therefore, the ability to resolve multi-exponential decay functions is an absolute requirement to get quantitative results. Resolving two or even more exponential terms in a decay function requires data with an excellent signal-to-noise ratio. Signal-to-Noise Ratio Due to the short lifetimes, the measurement of fluorescence decay functions requires a detection bandwidth in the GHz range. The high bandwidth does not only demand for very fast detectors and detection electronics, it poses also a noise problem. The noise in fast optical measurements is almost essentially shot noise, i.e. the fluctuation of the number of photons detected within the resolving time of the measurement system. The best signal-to-noise ratio, SNR, that can be achieved is SNR = n 1/2 with n being the number of photons detected within the resolved time interval. Actually the SNR can be even lower due to background signals originating in the detector or coming from the environment, random gain fluctuations in the detector, and inefficient acquisition of the detected photons in the subsequent signal processing chain. Acceptable steady state images can be obtained for less than 100 photons detected per pixel of the image. However, lifetime measurements actually deliver a stack of images for - in case of timedomain methods - different times after the excitation or - in case of frequency domain methods - for different phases and modulation frequencies. Therefore, the number of photons required to get lifetime information is much larger. Although rough lifetime information for single exponential can be obtained from only 100 detected photons high accuracy measurements for multi-exponential decay analysis can easily require or photons per pixel [80]. Unfortunately the number of photons that can be emitted from the sample in a given time interval is limited by the sample itself. Detection efficiency The detection efficiency for the photons emitted be the sample depends on the optical system and on the detector. The efficiency of a microscope depends on the numerical aperture of the microscope objective, NA, and increases with NA 2. The effective NA can be doubled by using the 4Pi technique [37]. It is often claimed that the efficiency for non-descanned detection is considerably higher than for descanned detection. This is certainly true for deep-tissue imaging when the emission light is scattered in the sample and cannot be fed through a pinhole. However, state-of the art microscopes have pinholes with adjustable diameter. For imaging single cells there is no noticeable difference between descanned and non-descanned detection. 13
17 Appreciable loss of photons can occur in the filters used to select the desired emission wavelength range. Using the right filter for a particular chromophore can improve the efficiency considerably. Commonly used detectors for lifetime imaging are described below. Although there is no appreciable difference between detectors of the same cathode type not all cathodes may be available for a particular detector. Techniques that are not restricted to a special detector, i.e. the photon counting techniques, can use high efficiency detectors, i.e. PMTs with GaAs cathodes or single photon avalanche photodiodes. Recording efficiency Different signal processing techniques differ considerably in terms of recording efficiency, i.e. in the exploitation of the detected photons. Taking into regard that the available number of photons is limited by photobleaching in the sample, the recording efficiency is the most important parameter next to the time resolution. The quality of a signal recording technique can be described by a figure of merit [38, 39], F, that describes the ratio of the signal-to-noise ratio SNR of an ideal measurement to the signal-to-noise ration actually achieved, i.e. SNR ideal F = SNR act F values for different methods were determined in [39]. Since the SNR is proportional to the square root of the number of detected photons, n, the efficiency of a technique in terms of photons required to obtain a given SNR is E = 1 / F 2 The figure of merit and the efficiency will be used in the discussion of the commonly used lifetime techniques. Sample Saturation The sample volume from which the photons are detected in a laser scanning microscope is of the order of 1 fl. For a chromophore concentration of 10-6 mol/l this volume contains only 600 molecules, and for 10-9 mol/l the number of molecules is of the order of 1. Lifetime measurements require a pulsed or modulated light source. To avoid saturation effects for pulsed excitation only a small fraction of the molecules can be excited by each pulse. Therefore, lasers with repetition rates in the khz range cannot reasonably be used in conjunction with scanning. There is, however, no saturation problem if lasers with a repetition rate above 50 MHz such as Ti:Sa lasers, YLF lasers or pulsed laser diodes are used. Photobleaching The most severe limit for the emission intensity is set by photobleaching in the sample. The chromophores are not infinitely stable but are destroyed after a large number of absorption and emission cycles. The reasons of photobleaching are not clear in detail and are probably different for one-photon and two-photon excitation. Possible reasons are simultaneous multi-photon absorption, intersystem crossing, reactions from the triplet state and excited-state absorption [40-45]. It is often claimed that photodamage and photobleaching is smaller for two-photon excitation. Certainly, there is no absorption outside the focus and consequently above and below the focal plane. Moreover, a cell can withstand much more power in the NIR than in the NUV because the fraction of absorbed power is much smaller [46,47]. However, if the cell contains dyes with a strong absorption around 400 nm and photobleaching is compared for the same number of emitted 14
18 fluorescence photons the situation is less clear. It has also been found that photobleaching is more rapid for two-photon excitation [41,42]. For two-photon excitation the dependence of the photobleaching efficiency on the excitation power is highly nonlinear. For photobleaching versus excitation power exponents of 2.5 [45] and from 3 to 5 for have been found [43]. At the same time the emission followed the excitation intensity by the expected power of 2. That means photobleaching increases more than linearly with the emission intensity. Therefore two-photon excitation can easily cause 10 times faster photobleaching than onephoton excitation for the same emission intensity [43]. Although photobleaching is the most crucial constraint for scanning microscopy the question about the excitation method is still open. The consequence from the controversial situation is not to rely on two-photon excitation alone. For all lasers commonly used for two-photon excitation frequency doubling is available and delivers sufficient power for one-photon excitation. Signal Processing Techniques Gated Image Intensifiers Gating an image intensifier is achieved by placing a grid behind the photocathode. The principle is similar as for the grid in a radio tube. As long as the grid voltage is negative referred to the photocathode the photoelectrons cannot pass the grid. When a positive pulse is applied the electrons pass through the meshes of the grid and are accelerated towards the multichannel plate or into the acceleration system. Although gating of an image intensifier looks straightforward at fist glance it is anything but simple, particularly if sub-ns resolution is to be achieved. Even if a sufficiently short gating pulse can be generated electronically the electrical field between the photocathode and the grid must follow the pulse at the same speed. Because the conductivity of the photocathode is relatively low the time constant formed by the gate-cathode capacitance and the cathode resistance limits the switching speed. Furthermore, a variable lateral field builds up in front of the photocathode that distorts the image and impairs the image resolution. Manufacturers counteract these effects by using high conductivity photocathodes which, however, compromises sensitivity. High efficiency GaAs and GaAsP photocathodes as they are used in PMTs have particularly low conductivity and are most likely not applicable for gated image intensifiers. Another RC time constant exists between the grid and the multichannel plate. Although the change of the field in front of the plate has only small influence on the gating performance it induces a lateral current in the multichannel plate that heats the device at high gate repetition rates. The gating resolution can also be impaired be electron-optical effects. When the gate voltage in the setup of fig. 16 is negative a cloud of photoelectrons builds up between the cathode and the grid. When a gate pulse is applied to the grid these electrons pass the grid and enter the detection system. Depending on the grid geometry, the lifetime of the photoelectrons between the grid and the cathode can be of the order of some 100 ps. The effects described above can be reduced by additional grids. Even then a lateral change of the gate delay due to the wave propagation in the grid structure remains. This effect is, however, predictable and can be corrected in the recorded data. Gate pulse -HV Photocathode Gate Multichannel Plate Fluorescence Screen CCD Camera Fig. 16: Gated Image Intensifier 15
19 Standard gated image intensifier devices have a minimum gate width of the order of a few ns. A device with 5ns gate width has been used to determine single exponential decay constants down to a few ns by deconvolution [33]. The shortest gate width obtained with gated image intensifiers is 50 ps for low repetition rate applications and 200 ps at a repetition rate of 80 MHz [20,51]. The general setup of a wide field and a scanning microscope with a gated image intensifier is shown in fig. 17. Pulsed Laser Reference Pulsed Laser Reference Telescope Variable Delay Gate Generator Gate Scan Control Scan Mirror Scan Lens Scanning Head Scan Mirror Variable Delay Gate Generator Gate Scan Control Gate Gate Image of Sample -HV Microscope Objective Sample + MCP - CCD Gated Image Intensifier Objective Sample Image of Sample -HV CCD Gated Image Intensifier + MCP - 16 Fig. 17: Wide field microscope (left) and scanning microscope (right) with gated image intensifier For time-resolved imaging a series of images is recorded for different delays of the gate pulse referred to the laser pulse (fig. 18). In a wide field microscope with a high repetition rate laser, such as a Ti:Sa or YLF laser with frequency doubler, the gate delay can be controlled idependently of the laser pulse sequence. The acqusition time for each image is simply chosen to get a sufficient signal-to-noise ratio. If a laser with khz repetition rate is used, the gate scan has to be synchronised with the laser, i.e. for each image a defined number of laser shots has to be acquired. If a gated image intensifier is used in conjunction with a scanning microscope [20,33], the gate scan must be synchronised with the frame scan rate of the microscope. Gate pulse Recorded photons Fluorescence A serious drawback of the gated image intensifier is the low counting efficiency. Due to the gating process, most of the photons collected from the sample are gated off. The counting efficiency is about the ratio of the gate width to the fluorescence lifetime and becomes more and more significant for shorter gate width. For a lifetime of 3.5 ns and a gate width of 200 ps [20] the efficiency is only 5.7 %. The F value [39], i.e. the ratio of the ideal to the actual SNR is The low efficiency must be compensated by a longer acqusition time with correspondingly more photobleaching in the sample. Although the multiple beam technique [48, 49] can be used to considerably reduce the acquisition time it does not really improve the detection efficiency. Gate Delay Gate Scan Fig. 18: Scanning a fluorescence decay function with the gate pulse
20 The counting efficiency can be improved by using a very wide gate and measuring the fluorescence with only two gate delays. Single exponential decay constants can be derived from the intensities in the two time windows analog to multi-gate photon counting [50]. Since the measurements for the two gates have to be done one after another the counting efficiency of such a measurement is close to 0.5, i.e. by a factor of two less than for multi-gate photon counting. In scanning microscope applications the gated image intensifier narrowly beats the multiple gate photon counting method for time resolution. The Pico Star System of La Vison [51] has a minimum gate width of 200 ps compared to 500 ps of the gated photon counting method [57,58]. However, the multiple gate photon counting method has a near-ideal counting efficiency, resulting in a correspondingly higher signal to noise ratio (SNR) for a given sample exposure. In a scanning microscope the image intensifier cannot compete with time-correlated photon counting (TCSPC) imaging [67,68,69] in terms of time resolution and counting efficiency. TCSPC currently achieves 25 ps resolution and an F value and a counting efficiency close to one. TCSPC is even able to record in several wavelength intervals simultaneously [68] - a feature that pushes the efficiency of TCSPC beyond the theoretical limit of any single channel detection technique. A gated image intensifier can be used for wide field illumination, for scanning with one-photon excitation and for scanning with two-photon excitation. However, it cannot be used in a confocal setup, and deep tissue two-photon images are blurred by scattering. The realm of gated image intensifiers is clearly the wide field microscope [23]. If wide field illumination has to be used for whatever reason, there is currently no replacement for the image intensifiers. Modulation Techniques Modulation techniques use modulated light to excite the fluorescence. Referred to the excitation light, the fluorescence light has a phase shift and a reduced modulation degree (fig. 19). Both depend on the fluorescence lifetime and on the modulation frequency: Excitation Sample Excitation Fluorescence Fluorescence tan ϕ f = ω τ f M f / M ex = 1 / sqrt ( 1 + ω 2 τ f 2 ) ω angular frequency of modulation, M ex modulation of excitation, M f modulation of fluorescence, ϕ f phase lag of fluorescence, τ f fluorescence lifetime Both the phase and the modulation can be used to determine the fluorescence lifetime. However, phase measurements are much more accurate than measurements of the modulation degree. Therefore normally the phase is used for lifetime measurements. The optimum frequency depends on the lifetime and is ω = 1 / τ f or f = 1 / 2Π τ f Fig. 19: Modulation technique Since fluorescence lifetimes are of the order of nanoseconds or picoseconds a modulation frequency between 50 MHz and several 100 MHz is used. To resolve the components of multi-exponential decay functions phase measurements at different frequencies are necessary. t 17
21 If a frequency between 100 MHz and 1 GHz is used the modulation method gives a time resolution in the ps range. For one-photon excitation the light source can be a modulated laser diode or a CW laser with an external modulator. For two-photon excitation a Ti:Sa laser is used and the phase is measured at the fundamental pulse frequency of the laser and at its harmonics. Taking into consideration the high frequency, the wide amplitude range of the fluorescence signal and the low signal-to noise ratio the phase measurement is anything but simple. Consequently, there are several modifications of the method depending on different excitation sources, detectors and phase measurement methods. Single Channel Modulation Techniques The general principle of the single channel modulation technique is shown in fig. 20. The light from the laser is modulated at a frequency in the range of 30 MHz to 1 GHz. The fluorescence light from the sample is detected by a PMT or a photodiode. The AC component of the detector signal is amplified and fed into two mixers that mix the signal with the modulation frequency at 0 and 90 phase shift. Mixing means actually a multiplication of the signals, therefore the outputs of the mixers deliver a DC component that represents the 0 and 90 components of the amplified detector signal. After low pass filtering the phase can be calculated from the mixer signals. The principle is analog to a dual-phase lock-in amplifier and often called lock-in detection [52,53]. The modulation technique can be used to record the fluorescence of several chromophores simultaneously in several parallel mixer systems. Several lasers which are modulated at different frequencies provide different excitation wavelengths. The emission of the sample is split into several wavelength ranges and detected by separate detectors. The detector signals are mixed with the modulation frequencies of the individual lasers in several parallel groups of mixers [52, 53]. Unfortunately high frequency mixers do not work well for DC output signals. Therefore, often a heterodyne principle, similar to that in a radio, is used (fig. 21). The detector signal and the modulation frequency are mixed with an oscillator frequency slightly different from the modulation frequency. The result are two signals at the difference frequency. The phase shift between the two signals is the same as between the detector signal and the modulation signal. Depending on the frequency difference, the output signals of the mixers are usually in the khz range. Therefore they can directly be digitised. The results of the AD conversion are filtered and used for phase measurement. The advantage of direct digitising is that effective digital filtering algorithms can be applied and the phase can be determined via fast Fourier transform [54, 55]. Continuous Laser Modulator Sample Generator Mixer Phase Calculation Detector Amplifier 0 90 Mixer Fig. 20: Modulation technique Laser Modulator Sample Generator f mod Oscillator Mixer f osc f mod - f osc digitiser A/D Detector A/D digital filter phase calculation Mixer digitiser Fig. 21: Heterodyne principle 18
22 A phase fluorometer of this type can be built up by using a commercially available network analyser and a laser diode. The setup is very simple - unless you have to build the network analyser. The principle is shown in fig. 22. The network analyser runs a frequency sweep over a selectable frequency interval. The output signal of the network analyser drives a laser diode that is used to excite the sample. The detected fluorescence signal is fed back into the signal analyser. The measurement delivers the phase and the amplitude of the signal as a function of the frequency. The network analyser is even able to correct the results by using reference data recorded with a scattering solution in place of the sample. The mixers used in fig. 20 and 21 can be replaced with a modulated detector (fig. 23). A setup of this type has been used for lifetime imaging in a two-photon laser scanning microscope [54]. A commercially available frequency synthesiser generates the modulation frequency, the oscillator frequency and the difference of both with a high frequency and phase stability. Mixing is accomplished by modulating the gain in a photomultiplier. The mixed signal at the output of the PMT has a frequency of 25 khz and is directly digitised. Further filtering and phase calculation is done digitally. The benefit of the detector modulation is that the modulation frequency is not limited by the bandwidth of the gain system of the PMT. Therefore relatively high modulation frequencies can be used. The drawback is that the detector is a very poor mixer. This results in a poor efficiency of the detector gain modulation technique. If a Ti:Sa laser is used in a modulation system, e.g. for twophoton excitation, the 80 MHz fundamental repetition frequency of the laser and its harmonics can be used as modulation frequency. Due to the short pulse width the Amplifier spectrum of the laser modulation is actually a frequency comb that extends up to THz frequencies. By proper tuning of the frequency synthesiser, any of the harmonics of the fundamental repetition frequency within the detector bandwidth can be used for the phase measurement. A heterodyne system with a Ti:Sa laser, two-photon excitation and modulated PMT delivered a lifetime accuracy of ± 300 ps for lifetimes between 2.4 and 4.2 ns [54]. This relatively poor accuracy is probably due to the short acquisition time of only 160 µs per pixel or 10 seconds for a 256 x 256 pixel image. Although the photon detection rate was estimated to be more than 10 8 photons/s - which is probably an overestimation - the accuracy is of the same order as for TCSPC imaging with 10 6 photons per second and the same acquisition time and pixel number. The efficiency of the single channel modulation technique in terms of photon counts strongly depends on the operating conditions. Results of Monte-Carlo simulations of the efficiency for single-exponential decay are given in [39]. The simulations yield F values, i.e. the ratio of the ideal SNR to the SNR achieved by the investigated method. For a setup with separate detector and mixer, sine-wave-modulated excitation, sine-wave mixing and 100% modulation of the excitation F was found to be 3.7. If the modulation is less than 100% a Laser Diode Network Analyser RF out Diode Bias Sample RF in Detector Amplifier Fig. 22: Phase fluorometer with a network analyser Frequency Synthesiser Laser Modulator Sample f mod f osc f mod - f osc digitiser A/D Gain modulated Detector A/D digital filter phase calculation f mod - f osc digitiser Fig. 23: Mixing by gain-modulating the detector 19
23 fraction of unmodulated light is detected which contributes to the noise, but not to the phase measurement signal. The SNR drops dramatically for less than 75% modulation [39]. Interestingly, in the same setup 100 % square-wave modulation of the excitation gives an F = 1.2, and Dirac pulse excitation even F = 1.1. This is a strong argument to use pulsed lasers, i.e. Ti:Sa or diode lasers rather than modulating CW lasers. For a gain-modulated detector the efficiency is much worse than for a detector and a separate mixer. The reason is that a gain modulated detector is a very bad mixer. True mixing means to multiply the detected signal with a sine wave, i.e. to invert the polarity of the signal for the negative half-period of the mixing signal. Of course, gain modulation at best means to change the gain between 100% and 0. Therefore a large fraction of the input signal remains unused, but contributes with its shot noise to the noise of the result. The F values for the modulated detector are around 4. That means, the technique needs 16 times more photons than techniques with a near-ideal F. For extremely low light levels the situation can be even worse. A high gain detector, such as a PMT, delivers a train of extremely short current pulses rather than a continuous signal. The pulses are due to the detection of the randomly arriving photons. If this pulse train is fed to a phase measurement circuitry described above a phase signal is produced only for a short time after the detection of a photon. In the times between the phase detector is unable to deliver a reasonable signal. What then happens depends on the phase detection electronics or the equivalent software algorithm. A normal phase detector in the absence of a signal delivers a huge noise. This noise is averaged with the randomly appearing phase signals for the individual photons. The result is a dramatic drop of the signal-to-noise ratio for low photon rates. For application with a scanning microscope it must be taken into regard that phase measurements are not compatible with the fast scanning speed of a state-of-the art laser scanning microscope. For the lock-in method the low pass filters must have time to settle, and the heterodyne method requires to record at least some periods of the difference frequency f mod - f osc. Therefore, minimum pixel dwell times are in the order of 40 to 160 µs. It is not clear whether a long pixel dwell time increases the photodamage in the sample. At least, the implementation of single channel modulation techniques in commercial scanning microscopes requires changes in the scan control of the microscope. Another problem can arise for deep tissue imaging with a confocal or two-photon microscope. In this case the presumption that the time-domain response of the sample is a sum of exponentials is questionable. Scattered excitation light and broadening of the fluorescence decay functions by scattering remain unnoticed unless a continuous sweep over wide frequency interval is performed. The conclusion is that the single channel modulation technique is not the best lifetime technique for scanning microscope applications. The true realm of the single channel modulation technique is in the infrared where no detectors with single photon sensitivity are available. Modulated Image Intensifiers The modulated image intensifier technique uses the same vacuum device as the gated image intensifier technique. However, the grid is driven by a sine wave or square wave signal rather than by a short gating pulse [55,56]. Modulation can also be achieved without a grid by modulating the voltage between the photocathode and the channel plate. As for the gated image intensifier, the problem is the low conductivity of the photocathode. The time constant formed by the gate-cathode capacitance and the cathode resistance limits the modulation frequency and introduces lateral phase variation across the image. Furthermore, a 20
24 variable lateral field builds up in front of the photocathode that distorts the image and impairs the image resolution. Modulating the voltage across the channel plate [55] has also been attempted. The drawback of this method is the heating of the channel plate due to dielectric losses and the low degree of modulation. The microscope setup for a modulated image intensifier is shown in fig. 24. The setup is very similar to that for the gated image intensifier. CW Laser Freqency Synthes. Pulsed Laser Freqency Synthes. AOM AOM Driver AOM AOM Driver Telescope Variable Phase Shift Scan Mirror Scanning Head Scan Mirror Variable Phase Shift Amplifier Scan Lens Amplifier Grid Grid Image of Sample -HV + MCP - Microscope Objective Sample CCD Image Intensifier Objective Sample Image of Sample -HV + MCP - CCD Image Intensifier Fig. 24: Modulated image intensifier used at a wide field microscope (left) and at a scanning microscope (right) A frequency synthesiser generates a modulation frequency which is typically in the range of 50 MHz to 500 MHz. This frequency is used to modulate the excitation light and the image intensifier. A variable phase shifter is used to change the phase relation between the modulation of the light source and the modulation of the image intensifier. From three images acquired at different phase shifts the phase of the fluorescence signal referred to the excitation can be calculated. Instead of the phase shifter a heterodyne technique can be used. In this case the image intensifier is modulated with a slightly different frequency than the laser. This causes the phase between the two modulations to change continuously. If the difference frequency is a few Hz a sequence of images can be obtained for each period of the difference frequency [55]. The heterodyne technique requires a good frequency synthesiser that delivers the two modulation frequencies and the difference of both with high frequency and phase stability. A single phase measurement at a fixed frequency allows to determine the time constant of a single exponential fluorescence decay function. To resolve the components of a multi-exponential decay measurements at different frequencies are required. Ideally, the modulation frequencies should be of the order of f mod = 1 / 2Πτ f with f mod = Modulation Frequency, τ f = Fluorescence decay time constant At this frequency the change of the phase is at maximum for a given change of the decay time constant. For decay components below a few 100 ps the optimum frequency is around 1 GHz. Modulation frequencies of this order are almost impossible to achieve with standard image 21
25 intensifiers. The dielectric losses cause heat dissipation in the intensifier tube structures, and there is a considerable phase shift between different parts of the image area. A modulated image intensifier can be used for one-photon and multi-photon fluorescence imaging with high repetition rate pulsed fs laser. The pulse train of the laser contains all harmonics of the fundamental repetition frequency. In the frequency domain the laser pulse train is actually a frequency comb that extends to THz range. Generally, by modulation the intensifier at the harmonics of the laser frequency a multi-frequency measurement can be accomplished [55,56]. A problem associated with this technique is that the gain modulation is nonlinear and therefore not ideally sinusoidal. Therefore the measurement signal obtained at a particular harmonic of the laser also contains a small fraction of higher harmonics. A drawback of the image intensifier technique is that it cannot be used in a confocal scanning microscope. Therefore depth resolution can only be achieved by two-photon excitation with a fs laser [55]. Even then the spatial resolution is limited by scattering of the emission light in the sample. The multiple beam technique described for the gated image intensifier in [48,49] is also applicable for the modulated intensifier technique. The efficiency of the modulated image intensifier in terms of photon exploitation has been investigated theoretically by Monte-Carlo simulations [39]. The F value, i.e. the SNR of an ideal measurement compared to the actually obtained SNR is 10 for sine-wave modulated exciatation and 4.3 for dirac modulation. That means the image intensifier needs 18.5 to 100 times more photons than techniques with perfect exploitation of the photons, e.g. time-correlated single photon counting. The reason for the high F values is that the gain can only be modulated between 0 and 1. Ideal mixing requires gain modulation between -1 and +1. Thus the modulation depth is only 50%. The F values are even worse if the modulation of the gain in the intensifier tube is less than 50% - which is certainly the case if a device without a grid is used. Moreover, the modulation is an efficiency modulation rather than a gain modulation - the photoelectrons from the photocathode are either rejected or transmitted into the channel plate. Therefore the efficiency is worse than for a detector with a subsequent mixer. The time resolution of the modulated image intensifier technique was reported to be down to a few 100 ps [55,56]. It is likely that much shorter lifetimes can be resolved if a sufficiently long acquisition time is used. Generally the resolution of frequency domain techniques cannot directly be compared to the resolution of time domain methods. The decay times are calculated from the phase (i.e. from a part of the Fourier spectrum) of the fluorescence signal. This calculation includes reference measurements for a reference sample or zero decay time for each frequency. Correctly, the resolution of frequency domain methods should be compared with the resolution of time-domain methods with deconvolution of the decay data. Deconvolution of TCSPC data obtained with an MCP PMT resolves single exponential decay times down to a few ps. Due to the low efficiency the modulated image intensifier technique it cannot be recommend as a lifetime method for laser scanning microscopes. However, the technique is applicable to wide field illumination. If wide field illumination has to be used for whatever reason there is currently no replacement for the gated and modulated image intensifier techniques. 22
26 Gated Photon Counters As all photon counting techniques, gated photon counting uses a fast, high gain detector that is usually a Pulsed Laser Sample PMT or a single photon avalanche photodiode. The single photon pulses from the detector are counted Detector within one or more time intervals. Due to the moderate Reference time resolution of the gating technique there are no special requirements to the transit time spread of the Variable Delay detector. However, the transit time distribution should Gate Counter not have a long tail, or bumps and prepulses or afterpulses and should be stable over the detection area. The principle of a gated photon counter with a single Gated Photon Counting (single gate) Fig. 25: Gated Photon counter with single gate gate is shown in fig. 25. To record the shape of a fluorescence decay function the gate pulse can be scanned over the time interval of interest by a variable delay generator. This method yields a decay curve with as many points as the delay unit has delay steps. However, the majority of the photons is discarded by the gating. Thus, the counting efficiency is low and the F value is of the same order as for the gated image intensifier. Although ready-to use gated photon counters are available nobody seriously considers to use this technique for lifetime imaging. A counting efficiency close to one can theoretically be achieved by a multiple gate architecture, fig. 26. The system Pulsed Laser Sample contains several parallel counters with individual gates. The gates are controlled via separate gate delays and by separate gate pulse generators. If the measured decay curve is Detector completely covered by subsequent gate pulses all detected photons are counted. Moreover, the parallel counter structure can be operated at extremely high count rates. Even Reference Variable Delay Gate Counter Variable Delay for count rates of several MHz there is almost no counting Gate Counter loss due to the short dead time of the counters. The practical implementation of the method is described in [57, 58]. Variable Delay Gate Counter Another benefit is that no special vacuum devices as for the Variable Delay Gate Counter image intensifier technique are required. The method immediately benefits from new detector developments, e.g. PMTs with high efficiency cathode materials [59,60]. Gated Photon Counting (multiple gate) Fig. 26: Gated photon counting with several gates Limitations of the method result from the relatively long gate duration and from the limited number of gate and counter channels. From the of signal-theory-point of view, the function of photon density versus time is heavily undersampled. In other words, the maximum frequency detectable in the signal spectrum is sampled less than 2 times per signal period. Undersampled signals cannot be reconstructed from the sample values without presumptions about the signal shape. 23
27 Fortunately, decay curves are either single exponentials or a sum of a few exponentials. Ideally, the lifetime of a single exponential decay can be calculated from the photons collected in only two time windows, see fig. 27. The optimum gate width was determined to be T = 2.5 τ f [38]. It has been shown that the components of multiexponential decay functions can be determined if the number of gates is increased [61]. However, practically the photons distribution is the convolution of the fluorescence decay function with the instrument response function (IRF), i.e. the excitation pulse shape, the detector TTS, the pulse dispersion in the optical system, and the effective shape of the gating pulse. The resulting fluorescence signal cannot be considered to be a sum of exponentials (fig. 28). To obtain the fluorescence lifetime from the intensity in two time windows these must be placed in a part of the fluorescence signal where the IRF has dropped below the noise level, i.e. in a region where the fluorescence signal is exponential. This, however, reduces the counting efficiency by discarding the most intense portion of the signal. Practically it is probably better to tolerate some error in the lifetime calculation and to calibrate the system by using known fluorescence lifetimes. However, for double- or multi-exponential decay functions a calibration appears difficult if not impossible. The shortest gate width that has practically been used is of the order of 500 ps. Although lifetimes down to 70 ps have been measured with reasonable accuracy it is difficult to measure lifetimes below 200 ps. Double exponential decay functions of FRET systems with a fast component of 100 to 300 ps probably cannot be resolved. Practical devices based on multi-gate photon counting work with a direct readout of the counters after the acquisition of each pixel of the image [57]. This sets a lower limit to the pixel dwell time in the 10 us range. Consequently, the maximum scan speed of a laser scanning microscope cannot be exploited. It is not clear whether this increases the photobleaching of the sample via accumulation of triplet states or heat concentration in the scanned spot. The problem - if it exists - could easily be overcome by implementing a memory that accumulates the results in memory locations according to the x,y location of the laser spot in the scanning area. For samples containing different chromophores the counting efficiency and the amount of information in the data can be improved by recording the fluorescence in several wavelength channels simultaneously. Steady-state multi-wavelength imaging has been successfully used to separate different chromophores in stead-state images [13]. The gated photon counting technique basically can be used with several detectors if the number of gate and counter channels is increased. Several gates can be driven by the same delay and gate pulse generator so that the increase of system complexity is less than proportional. Although a multi-wavelength gated SPC system has not become known yet it could improve the selectivity for different chromophores considerably. Theoretical investigation of the efficiency [39] delivers an F value of 1.5 for two gates of a width of 2.5 τ. For 8 gates with unequal width F = 1.1 can be achieved. However, practically τ is unknown and varies throughout the image so that the gate width is usually not optimal. Furthermore, the first 24 Ia T e -t/tau T tau = ln ( Ia / Ib ) Ib Fig. 27: Calculation of fluorescence lifetime from intensities in two time intervals, ideal IRF Instrument Response Function (IRF) Fluorescence Signal Ia T T e -t/tau ~ T tau = ln ( Ia / Ib ) Fig. 28: Calculation of fluorescence lifetime from intensities in two time intervals, real IRF Ib T
28 part of the signal can probably not be used because it is convoluted with the system response. Assuming a loss of a factor of two in the number of counted photons the +method ends up at F = 1.5 to 2.1 which is much better than for the image intensifiers and noticeably better than sine-wave modulation techniques. Acquisition times for biological samples stained with highly fluorescent dyes are in the range 10 to 100 seconds [58,11]. Generally the acquisition times for comparable lifetime accuracy should be expected in the same range as for TCSPC imaging (see below) unless count rates exceeding 5 MHz are available. As for TCSPC imaging, the acquisition time can be reduced by decreasing the number of pixels of the scan. Multi-gate photon counting has its merits in applications that require to record lifetimes in the range of a few ns at high count rate and with short acquisition times. Typical applications are lifetime imaging with marker dyes for Ca++, Na+, O-- or other parameters within cells and tissue [11b]. Probing of DNA and RNA by the lifetime change of SYTO13 is described in [11, 11a]. 25
29 Time-Correlated Single Photon Counting (TCSPC) Time-Correlated Single Photon Counting is based on the detection of single photons of a periodical light signal, the measurement of the detection times of the individual photons and the reconstruction of the waveform from the individual time measurements [62, 63]. The principle is shown in fig. 29. The fluorescence is excited by a pulsed laser with a repetition rate of typically 80 MHz. The fluorescence photons are detected by a fast PMT, MCP or a single photon avalanche photodiode. For precision measurements these detectors allow count rates of the order of a few MHz, i.e. much less than the laser repetition rate. The TCSPC method makes use of the fact that the detection of several photons in one laser period is small enough to be neglected. When a photon is detected the time of the corresponding detector pulse in the laser pulse sequence is measured. The measured times are used to address a histogram memory in which the photons are accumulated. After acquiring a large number of photons the photon density versus time builds up in the memory. Detector Signal: Period 1 Period 2 Period 3 Period 4 Period 5 Period 6 Period 7 Period 8 Period 9 Period 10 Period N Result after collecting many Photons Optical Waveform Time The method may look circumstantial at first glance, but it has some striking benefits - a near-ideal counting efficiency and an ultra-high time resolution. memory location Fig. 29: Time-correlated single photon counting As long as the count rate is not so high that the conversion time of the time measurement and histogramming procedure becomes noticeable there is no loss of photons. The F value describing the ratio of the ideal SNR to the actually obtained SNR is < 1.1 [38,39]. The resolution is limited by the transit time spread in the detector, by the timing accuracy of the discriminator that receives the detector pulses and by the accuracy of the time measurement. With an MCP-PMT the width of the instrument response function is of the order of 25 to 30 ps. The width of the time channels of the histogram can be made less than 1 ps [63]. Therefore, the instrument response function is sufficiently sampled to determine lifetimes down to a few ps. The TCSPC technique is often believed to be extremely slow and unable to reach short acquisition times. This ill reputation comes from older NIM systems used in conjunction with low repetition rate light sources which are indeed not applicable for time-resolved imaging. However, high count rate techniques exist [64] since the late 80s. An early - probably the first - implementation of TCSPC in a microscope is described in [65]. State-of-the-art TCSPC devices use a new conversion principle and achieve count rates of several 10 6 photons per seconds [63]. A system with four parallel TCSPC channels and 20 MHz useful count rate is described in [66]. The system was used in a slow-scan setup for optical tomography and can be combined with a multi-detector technique [63,66]. Although a combination with a scanning microscope has not become known yet the system is basically able to record images in up to 32 detector channels with slow scan rates at count rates comparable to multi-gate photon counting [57]. 26
30 TCSPC Imaging TCSPC Imaging is an advanced TCSPC technique used in conjunction with scanning microscopes. The method builds up a three-dimensional histogram of the photon number over the time and the coordinates of the scan area. The principle is shown in figure 30. The recording electronics consists of a time measurement channel, a scanning interface, and a large histogram memory. The time measurement channel contains the usual TCSPC building blocks. Two constant fraction discriminators, CFD, receive the single photon pulses from the detector and the reference pulses from the laser. The time-to-amplitude converter, TAC, measures the time from the detection of a photon to the next laser pulse. This reversed start-stop principle is the key to the processing of high laser repetition rates. The analog-digital converter, ADC, converts the TAC output voltage into an address for the memory. Detector Timing Start Stop from Laser Time Measurement CFD TAC ADC CFD t Time within decay curve Frame Sync Line Sync Pixel Clock from Microscope Counter Y Scanning Interface Counter X y Histogram Memory x Location within scanning area Fig. 30: TCSPC Imaging The scanning interface is a system of counters. It receives the scan control pulses from the microscope and determines the current position of the laser beam in the scanning area. When a photon is detected the device determines the time, t, within the fluorescence decay curve and the location of the laser spot within the scanning area, x, y. These values are used to address the histogram memory. Consequently, in the memory the photon distribution versus t, x, and y builds up. The result can be interpreted as a stack of images for different times after the excitation pulse or as an array of pixels containing a complete fluorescence decay function each. The implementation of TCSPC imaging into Zeiss microscopes is described in [67-69]. The described instrument consist of a Zeiss LSM-510 NLO Laser scanning microscope, a femtosecond Ti:Sa laser, a fast PMT, and a Becker & Hickl SPC-730 TCSPC imaging module [63]. The setup is shown in fig
31 Zeiss b&h SPC-730 TCSPC Imaging Module PMH ps R3809U <50ps Detector Fibre Output start stop Ti Sa Laser 80 MHz 200 fs LSM-510 Scanning Head Axiovert Pixel Clock, Line Clock, Frame Clock User I/O Microscope Control Box 28 Fig. 31: Setup of the lifetime microscope The setup does not require any changes in the microscope or in the associated control software. The fibre output option of the LSM-510 scanning head is used to feed the detected light into the photomultiplier. Depending on the required resolution either a PMH-100 detector head of Becker & Hickl or an R3809U MCP-PMT of Hamamatsu is used. For each photon, the detector delivers a start pulse to the SPC-730 TCSPC imaging module. The stop pulse for the time measurement is obtained from the monitor diode of the laser. The recording in the SPC-730 TCSPC module is synchronised with the scanning via the Pixel Clock, Line Clock and Frame Clock signals from the control box of the microscope. The system response for a Hamamatsu R3809U fwhm=30ps MCP is shown in fig. 32. The instrument response width is 30 ps for an MCP supply voltage of V. Usually, deconvolution of the measured fluorescence decay from the system response delivers decay at least times 10 time shorter than the system response, i.e. less than 3 ps. Deconvolution requires to record the instrument response function (IRF), which is simple in a onephoton microscope. However, in a two-photon microscope the IRF is difficult to record because the excitation wavelength is blocked by filters, or detectors are used which are insensitive at the excitation wavelength. Furthermore, the sample is excited by a two-photon process while the detector sees the response via one-photon photoemission. For standard applications a best guess system response can be calculated from the rising edge of the fluorescence decay functions themselves. The shortest lifetime that can reasonably be determined this way is in the range of the IRF width, i.e. 20 to 30 ps. For precision measurements an ultra-short fluorescence or a nonlinear crystal can be used to record the IRF. Lifetime images obtained by TCSPC imaging are Fig 32: Instrument response for the R3809U-50 MCP 0.3 Lifetime, ns 1.2 Fig. 33: Lifetime image of a sample stained with three different dyes (Leica TCS SP2, SPC-730)
32 presented in [67-75]. An example is shown in fig. 33. The sample is stained with three different dyes which are clearly distinguished in the lifetime image. An application to FRET imaging (after [68]) is shown in figure ns 2ns 1 Lifetime, single exponential approximation Ratio of intensity coefficients, fast/slow 2 Fig. 34: HEK cell containing CFP and YFP in the α and β subunits of the sodium channels. Left: Lifetime image of donor, CFP, centre: Decay curves of selected pixels, right: FRET image showing ratio of intensity coefficients of quenched and unquenched fluorescence components Data from [68], Zeiss LSM-510, Becker & Hickl SPC-730 The sample is an HEK cell containing CFP and YFP in the α and β subunits of the sodium channels. Since the emission spectrum of CFP overlaps the absorption spectrum of YFP FRET is expected in regions where the subunits are close together. Fig. 34, left, shows a lifetime image of the donor, CFP, obtained from a single exponential fit through the decay functions in the individual pixels. Fig. 34, centre, shows decay curves of two selected pixels from the yellow (short lifetime) and blue (long lifetime) area of the lifetime image. Double exponential decay analysis yields two decay components of about 380 ps and 1.8 to 2 ns throughout the image. However, the intensity coefficients, a, differ considerably in different parts of the cell. Assuming that the lifetime components belong to the quenched and unquenched donor molecules the ratio of the intensity coefficients, a fast / a slow, should represent the ratio of the number of quenched and unquenched CFP molecules. Therefore the ratio of the coefficients can be used as a measure for the FRET intensity. Fig. 34, right shows a FRET image displaying the number of photons as brightness and a fast /a slow as colour. Multi Wavelength TCSPC Imaging For samples containing different chromophores the counting efficiency and the amount of information in the data can be increased by recording the fluorescence in several wavelength channels simultaneously. Multi-wavelength imaging has been successfully used to separate different chromophores in stead-state images [13]. TCSPC detection of single molecules in four wavelength channels considerably improves the selectivity for different molecules [17]. TCSPC imaging can be combined with a multidetector technique [63,66,76,77] and be used to record the photon density over time, wavelength and the coordinates of the scanning area [72]. The principle of the multi-detector technique is shown in fig
33 R5900L16 Discriminators Encoder Detectors Discriminators Encoder 1 3 bit Channel Number bit Channel Number 16 Don t Count Don t Count Photon Pulse R3809U Photon Pulse Inverting Amplifier Summing Amplifier Fig. 35: Multi-detector technique for TCSPC. Left: Multichannel PMT, Right: Individual PMTs The technique works both with a multichannel PMT [72a,77] and with several individual PMTs or MCPs [72b,66,76]. It makes use of the fact that the detection of several photons in different detector channels in one laser period is unlikely. Therefore, the single photon pulses from all detector channels can be combined into a common photon pulse line and send through the normal time measurement procedure of the TCSPC module. The output of each PMT channel is connected to a discriminator. If the channel detects a photon the corresponding discriminator responds and sends a pulse to the subsequent encoding logic. The encoder delivers the number of the PMT channel that detected the photon. The channel number is used as an additional dimension in the multidimensional histogramming process of the TCSPC imaging technique. The recording electronics for multi-wavelength TCSPC imaging consists of a time measurement channel, a scanning interface, a detector channel register, and a histogram memory (fig. 36). from Polychromator Channel Detector Timing Start Stop from Laser Channel register Time Measurement CFD TAC ADC CFD n t Channel / Wavelength Time within decay curve Frame Sync Line Sync Pixel Clock from Microscope Counter Y Scanning Interface Counter X y x Histogram Memory Detector channel 1 Histogram Memory Detector channel... Location within scanning area Histogram Memory Detector channel... Histogram Memory Detector channel Fig. 36: Multi-wavelength TCSPC lifetime imaging For each photon, the time measurement channel determines the detection time (t) referred to the next laser pulse. The scanning interface determines the current location (x and y) of the laser spot in the scanning area. Synchronously with the detection of a photon, the detector channel number (n) for the current photon is read into the detector channel register. If a polychromator is used in front of the detector, n represents the wavelength of the detected photon. The obtained values for t, x, y and n are then used to address the histogram memory. Thus, in the memory the distribution of the photons over time, wavelength, and the image coordinates builds up. The result is a four-dimensional data array that can be interpreted as a set of image stacks for
34 different wavelengths. Each stack contains a number of images for subsequent times after the excitation pulse. Fig. 37 shows a HEK 293 cell expressing a hybrid protein in which the cyan (CFP) and yellow (YFP) shifted mutants of the green fluorescent protein are linked together by a short amino acid chain. The setup used for this measurement [72a] consisted of a laser scanning microscope (LSM-510, Zeiss), a polychromator (250is, Chromex), and a 16 channel TCSPC detector head [77] connected to an SPC-730 TCSPC imaging module [63]. The setup recorded the wavelength range from 410 nm to 635 nm in 16 wavelength channels, covering the emission bands of CFP and YFP. The image below was obtained by summing the photons from all time channels of the CFP fluorescence. CFP Fig. 37: HEK 293 cell expressing a CFP-YFP hybrid protein Left: Intensity image of CFP. Right: Fluorescence decay curves of CFP and YFP in a selected region (square). Fluorescence decay analysis in a selected region (small square) reveals a double-exponential decay both for CFP and YFP. The intensity coefficient of the fast component is positive for CFP and negative for YFP, indicating that energy is transferred from CFP to YFP. In Fig. 38 the intensity is represented by the brightness, the ratio of the coefficients by the colour of a pixel. The results are shown for the CFP and the YFP fluorescence. CFP YFP Fig. 38: FRET images for CFP (left) and YFP (right) of a HEK cell expressing a hybrid protein in which CFP and YFP are linked together by a short peptide. The brightness represents the intensity, the colour the ratio of the amplitudes of the fast and slow decay components. From [72a] 31
35 Features of the TCSPC imaging techniques It should be pointed out that neither single wavelength nor multi-wavelength TCSPC imaging use any time gating or wavelength scanning. Therefore, both techniques yield a near-perfect counting efficiency and a maximum signal to noise ratio for a given acquisition time. Due to the short dead time of the TCSPC imaging electronics (125 to 180 ns ) [63] there is almost no loss of photons for count rates up to a few 10 5 /s as they are typical for cell imaging. The time resolution of the TCSPC techniques is given by the transit time spread in the detector. A system response of only 25 ps FWHM is achieved with MCP PMTs. In conjunction with a minimum time channel width of the TCSPC modules of less than 820 fs [63] lifetimes down to a few ps can be measured. No special vacuum devices as for the image intensifier technique are required. The method immediately benefits from new detector developments, e.g. ultra-fast MCP PMTs or new high efficiency cathode materials. Implementing TCSPC imaging into a laser scanning microscope requires no more changes than attaching a fast detector to the microscope. In most microscopes this is possible either via a fibre output or via the non-descanned port. TCSPC imaging works at the full scan rate of the laser microscope, i.e. with pixel dwell times of order of 1 µs. Due to the synchronisation via the scan control pulses the zoom and image rotation functions of the microscope can be used also for lifetime imaging. Currently available TCSPC imaging devices have a limited memory space. Therefore, a tradeoff between the number of pixels, the number of time channels and the number of detector channels has to be made. However, with the introduction of the SPC-830 module of bh memory space is not longer a severe constraint. Some combinations of image size, and number of time and wavelength channels for the SPC-830 are given in the table below [63]. 32 Detector Channels Resolution x,y Time Channels Min. Time Channel Width (ps) x x x x x x x x x x x x x Parallel operation of two modules connected to the same detector can be used to simultaneously obtain images with high pixels resolution and moderate time resolution and images with moderate pixel resolution and high time resolution. Although no such system has become known yet the implementation with current TCSPC modules is straightforward. The maximum photon count rate of the TCSPC technique is limited by the time required to measure the time of a detected photon and to store it in the histogram memory. This dead time is of the order of 125 to 180 ns for state-of-the art devices. Becker & Hickl define a maximum useful count rate which means the recorded photon rate at which 50% of the photons are lost in the dead time [63]. Maximum useful count rates are in the range of 3 to 4 MHz. The counting efficiency and
36 the figure of merit [39] as a function of the detector count rate for different techniques are shown in fig. 38. The values for the image intensifiers and single channel nmodulation techniques were taken from [39], the value for multi-gate photon counting from [81]. 1 Efficiency 0.8 TCSPC, 1 Channel Modulation TCSPC, 4 Channels 4 F Figure of Merit Image Intensifiers Modulation Multi Gate SPC Multi Gate SPC TCSPC, 4 Channels 0 10 khz Modulation Image Intensifiers 100 khz 1 MHz 10 MHz Detector Count Rate khz Modulation 100 khz TCSPC, 1 Channel 1 MHz 10 MHz Detector Count Rate Fig. 38: Counting efficiency and figure of merit F of TCSPC imaging compared to other techniques F is the ratio of theoretical SNR to obtained SNR, F=1 means ideal SNR Surprisingly, TCSPC imaging beats the other methods even for detector count rates of the order of 5 to 10 MHz. It is unlikely that such high count rates can be obtained from living cells. Anyway, a count rate above 5 MHz imposes overload problems to most detectors. Although traditional PMTs still work at 10 MHz the timing performance may not longer meet the high standard of the TCSPC method. MCP PMTs, i.e. the fastest detectors for TCSPC, are clearly overloaded above 1 MHz. If a system is to be operated at extremely high count rates the solution is the multidetector technique. If the light is split into several detection channels the load for the individual detectors is reduced. Another solution is to operate several TCSPC modules with individual detectors in parallel. Although no such application has become known yet the implementation is straightforward. The Becker & Hickl TCSPCs are designed to work in packages of up to four devices [63]. The acquisition time for TCSPC lifetime measurements can vary in a wide range. In vivo lifetime measurements at the human ocular fundus in conjunction with an ophthalmologic scanner delivered single exponential lifetimes for an array of 128x128 pixels within a few seconds [75, 75b]. On the other hand, for the double exponential decay data of FRET measurements acquisition times from 5 to 30 minutes were used [68]. In practice the acquisition time depends on the required lifetime accuracy, on the number of lifetime components to be resolved, on the number of pixels and wavelength channels and on the count rate that can be obtained from the sample without photobleaching or photodamage. Fig. 39 shows the acquisition time as a function of the product of the number of pixels and the number of wavelength channels. The left diagram is for a high count rate of 10 6 /s. Count rates of this order can be obtained by one-photon excitation from cells containing high chromophore concentrations. For two-photon excitation a count rate of 10 6 /s requires extremely stable samples stained with very efficient chromophores. The right diagram is for a very low count rate of 10 4 /s. Count rates of this order are typical for autofluorescence of cells and tissue and for samples with low photostability. An HEK cell 33
37 containing CFP and YFP measured by two-photon excitation with 150 fs pulses at 820 nm [68] delivered only 10 4 photons/s. Nevertheless, it photobleached to 50% intensity within 10 minutes s Acquisition Time 1000s 100s Count Rate 10 6/s 100,000 10, s Acquisition Time 1000s 100s Count Rate 104 /s 100,000 10, s s 100 1s 100ms 10ms 100 Photons/ Pixel 1s 100ms 10ms Photons/ Pixel 1ms 1ms 0.1ms , ,000 Pixels x Wavelength Channels 0.1ms , ,000 Pixels x Wavelength Channels Fig. 39: Acquisition times for a count rate of 10 6 /s (left) and 10 4 /s (right) for different numbers of photons per pixel. Photons per pixel range from 100 for rough single exponential decay mapping to 10 5 for precision double exponential decay analysis. Fig. 39 shows that relatively long acquisition times must be expected, particularly for large numbers of pixels and precision measurements of samples at a low count rate. However, it should be pointed out that long acquisition times are not a special feature of TCSPC imaging - they simply result from the fact that much more photons per pixel are required to determine the lifetime than to record the intensity. Shorter acquisition times can be achieved if the scanning area is confined to a few pixels or only one pixel is measured. For single pixels the acquisition time can be in the ms or sub-ms range. That makes it possible to investigate diffusion processes by monitoring the lifetime change in a single pixel. Even fast FRET measurements appear feasible. FRET requires to resolve the components of a double exponential decay function. This requires about 10,000 photons which can be obtained in 10 ms. Even if the emission intensity of biological samples is limited there is probably still some potential to increase the count rate by improving the detection efficiency. The transmission band of filters used to select the emission from a particular chromophore are often narrower than the emission band. Optimising the filters can easily yield a factor of two in sensitivity. Moreover, in a normal microscope the photons are collected from one side of the sample only. The 4Pi technique [37] collects the fluorescence from both sides and therefore gives a factor of two improvement in collection efficiency. In cases where the full diffraction-limited resolution of the objective is not required the count rate can probably be increased by increasing the excited sample volume. Photobleaching is reported to be highly nonlinear, therefore the larger volume allows to use more excitation power and consequently to get more photons [43,45]. By introducing defined distortions into the wavefront of the excitation path or by under-illuminating the aperture of the objective the excited volume can be increased without impairing the photon collection efficiency. Recently new photomultiplier cathodes with a 3-fold improved sensitivity compared to traditional bialkali and multialkali cathodes became available. Fast PMTs and MCPs with the new cathodes have an IRF width of 300 ps and 100 ps respectively [59,60]. 34
38 Other TCSPC Techniques Application of TCSPC to diffusion in cells Diffusion constants in cells are usually determined by fluorescence correlation (FCS) techniques. Recording an FCS function requires to detect the fluorescence intensity in a fixed spot of the sample and to calculate the autocorrelation function of the intensity or of the photon detection times [14,15,16]. Although FCS is not an imaging technique it is often used in combination with imaging to define the location in a cell where an FCS measurement has to be run. Generally, the TCSPC technique is not only able to record time-resolved images in laser scanning microscopes, but also to recorded FCS data. An FCS measurement can even be combined with a single point lifetime measurement. The multi-detector technique described above for TCSPC imaging is also available for FCS measurements. With the introduction of the SPC-830 it is not longer necessary to use independent modules for imaging and FCS. The SPC-830 works for imaging and FCS recording as well. FCS data recording does not build up histograms as the TCSPC imaging techniques do. Instead, it records the full information about each photon. Each entry contains the time of the photon in the laser pulse ps time from TAC / ADC micro time resolution 25 ps sequence, the time from the start of the experiment, and the detector channel. The data structure is shown in Fig. 40. For each detector an individual correlation spectrum and a fluorescence decay curve can be calculated. An instrument like this was used to detect and identify single molecules on a substrate. By using four wavelength channels and a piezo scanning stage different molecules could be identified in a time of the order of 1 ms [17]. Moreover, data from different detectors can be cross-correlated. By detecting different chromophores in different wavelength intervals crosscorrelation can show whether the molecules of both chromophores and the associated protein structures are linked or diffuse independently. Laser FIFO Buffer Photon Histogram of micro time micro time micro time... micro time micro time picoseconds Laser Fluorescence decay curves Detector Channel Det. No Det. No Det. No Det. No Readout Hard disk time from start of experiment Start of experiment Photons macro time resolution 50 ns macro time macro time... macro time macro time Autocorrelation of macro time ns to seconds Fluorescence correlation spectra Fig. 40: Combined liftime / FCS data acquisition by TCSPC TCSPC Wide Field Imaging TCSPC can be used for wide field imaging if a special detector is used. The detector consists of the usual photocathode, a microchannel plate and a delay line system or a four-element anode system at the output. By measuring the delay of the output pulses at the ends of the delay lines or the charge distribution at the four anode sectors the location of a photon can be determined, see fig
39 Cathode Cathode Multichannel Plate Multichannel Plate A2 A1 A2 A1 Delay Line Anode A3 Quadrant Anode A4 Fig 41 : Wide field detectors for TCSPC Wide-field TCSPC imaging requires several TCSPC channels or one TCSPC channel with four low noise charge detection channels. The technique features high counting efficiency and relatively good time resolution. Because additional signal processing is needed to obtain the position of a photon it is difficult to reach high count rates. The most severe drawback is that the technique depends on complex detectors that are not commonly available. Comparison of Signal Processing Techniques A comparison of the different lifetime techniques is given below. The figure of merit, F, was taken from [39]. Small F values indicate high efficiency. For multiwavelength techniques it was assumed that two chromophores are measured which give approximately the same count rates. Therefore, the efficiency, E, increases by a factor of 2 and F is reduced by a factor of 1.4. The resulting F can be smaller and E greater than one because the values are referred to a single detector measurement with ideal SNR. For the time resolution of the gated image intensifier and the TCSPC technique it was assumed that lifetimes down to 1/10 of the instrument response width can be de-convoluted, which is certainly a conservative assumption. The resolutions given for the modulation techniques are the practically obtained values from [19, 21,52-54]. The applicability to multi-exponential decay functions is more or less theoretical. Resolution of double exponential decay functions in FRET systems has been proved for TCSPC only. The maximum count rate of the TCSPC method was defined as the rate at which the counting efficiency drops to 50%. Therefore, the values are smaller that the reciprocal dead time. 36
40 Technique F E Reso- Count Multi- Fast Con- Remark Figure Effi- lution Rate Epon. Scan focal of Merit ciency ps MHz Decay Gated Image Intensifier 200ps unlim. yes yes no applicable for wide field Single Channel mod. Sinewave unlim. yes no yes slow scan only Technique Dirac unlim. yes no yes Modulated Image Sinewave unlim. yes yes no applicable for Intensifier Dirac unlim. yes yes no wide field Multi-Gate SPC 2 Gates no no yes 8 Gates < yes no yes 2 λ Channels 2 Gates, no no yes 4 Detectors TCSPC Imaging, 100 khz 4) ) 4 1) yes yes yes 1 detector 1 TCSPC Channel 1 MHz 4) ) 4 1) yes yes yes TCSPC Imaging 100 khz 4) ) 2 5) 2.5 3) 16 2) yes yes yes 4 detectors, 4 TCSPC Channels, 1 MHz 4) ) 16 2) yes yes yes 4 parallel TCSPC 4 λ Channels, 4 MHz 4) ) 16 2) yes yes yes channels 2 Chromophores 10 MHz 4) TCSPC Multiwave- 100 khz 4) ) 2 5) 2.5 3) 4 1) yes yes yes up to 16 detector length Imaging, 1 MHz 4) ) 4 1) yes yes yes channels recording 2-16 λ Channels, simultaeously in 2 Chromophores 1 TCSPC channel 1) Count rate for 50% counting loss. Dead time 150ns 2) Count rate for 50% counting loss. Four parallel channels with a dead time of 150ns each 3) With MCP-PMT 4) Overall count rate 5) F < 1 and E > 1 because 2 chromophores are detected simultaneously and the system is compared with a single channel detecting only 1 chromophore Summary A wide variety of lifetime imaging techniques for time-resolved microscopy is available - gated and modulated image intensifiers, single channel modulation techniques and gated and time-correlated single photon counting. At the same time two generally different microscopy techniques exist - the wide field microscope and the confocal or two-photon laser scanning microscope. For wide field microscopy the gated and modulated image intensifiers and can be used. Wide-field lifetime systems do not have the intrinsic depth resolution and optical sectioning capability of the confocal and two-photon scanning systems. For laser scanning microscopes the best results are achieved with multi-gate photon counting and with the TCSPC imaging technique. Multi-gate photon counting can be used up to very high count rates and efficiently detects single exponential lifetimes down to a few 100ps. It does, however, not reach the efficiency and the time-resolution of TCSPC. It is not clear how far the high count rate of the technique can be practically exploited because photobleaching sets a limit to the fluorescence intensity obtained from the excited sample volume. TCSPC is able to detect lifetimes down to a few ps and is able to resolve the components of multiexponential decay functions. It has a near-ideal efficiency and is able to detect in several wavelength intervals simultaneously. Moreover, the TCSPC technique can be used to obtain combined 37
41 FCS / lifetime data in selected spots of a sample. TCSPC imaging works at an extremely high scanning speed and is therefore compatible to almost any laser microscope. Among all methods TCSPC imaging with confocal or two-photon microscopes scanning microscopes is most suitable to meet the requirements of cell imaging - optical sectioning, multiwavelength recording, high detection efficiency, high time resolution, resolution of multiexponential decay functions, and applicability of FCS techniques. References [1] M. Minsky : Memoir on inventing the confocal microscope. Scanning 10, (1988). [2] J.G. White, W.B. Amos, M. Fordham : An evaluation of confocal versus conventional imaging of biological structures by fluorescence light microscopy. J. Cell Biol. 105, (1987). [3] W. Denk, J.H. Strickler, W.W. Webb, Two-photon laser scanning fluorescence microscopy. Science 24 (1990) [4] A. Periasami, M. Elangovan, H. Wallrabe, J.N. Demas, M. Barroso, D.L. Brautigan, R.N. Day, Methods in cellular imaging (ed. by A. Periasamy), , Oxford University Press, New York [5] B. Herman, Fluorescence Microscopy, 2nd. edn. Springer-Verlag, New York 1998 [6] J.R. Lakowicz, Principles of Fluorescence Spectroscopy, 2nd. Ed., Plenum Press, New York 1999 [7] A. Periasami, R.N. Day, Visualizing protein interactions in living cells using digitized BFG imaging and FRET microscopy, in: Green Fluorescent Proteins, ed. by K.F. Sullivan, S.A Key, Academic Press, 1999 [8] M. Elangovan, R.N. Day, A. Periasami, Nanosecond fluorescence resonance energy transfer-fluorescence lifetime imaging microscopy to localize the protein interactions in a single cell. J. Microsc. 205 (2002) 3-14 [9 ] W.R.G. Baeyens, D. de Keukeleire, K. Korkidis, Luminescence techniques in chemical and biochemical analysis, M. Dekker, New York, 1991 [10] M.R. Eftink, Fluorescence quenching: Theory and application, in: J.R. Lakowicz, Topics in fluorescence spectrocopy, Vol. 2 (1991) [11] M.A.M.J. van Zandvoort, W. Engels, C.J. de Grauw, H.C. Gerritsen, D.W. Slaaf, Lifetime imaging of the vital DNA/RNA probe SYTO13 in helthy and apoptitic cells. Proc. SPIE (2002) [11a] Van Zandvoort, M.A.M.J., de Grauw, C.J., Gerritsen, H.C., Broers, J.L.V., Egbrink, M.G.A. Ramaekers, F.C.S., Slaaf, D.W. Discrimination of DNA and RNA in cells by a vital fluorescent probe: Lifetime imaging of SYTO13 in healthy and apoptotic cells. Cytometry 47 (2002) [11b] Gerritsen, H.C., Sanders, R., Draaijer, A., Levine, Y.K. Fluorescence lifetime imaging of oxygen in cells. J. Fluoresc. 7 (1997) [12] Jens-Peter Knemeyer, Nicole Marmé, Markus Sauer, Probes for detection of specific DNA sequences at the single molecule level. Anal. Chem. 72 (2000) [13] M. E. Dickinson, C.W. Waters, G. Bearman, R. Wolleschensky, S. Tille, S.E. Fraser, Sensitive imaging of spectrally overlapping fluorochromes using the LSM 510 Meta. Proc. SPIE 4620 (2002) [14] Thomson, N,L., Fluorescence Correlation Spectrocopy. Topics in Fluorescence Spectroscopy, Vol. 1, ed. by J.R. Lakowicz, Plenum Press, New York, 1991 [15] K.M. Berland, P.T.C. So, E. Gratton, Two-photon fluorescence correlation spectroscopy: Method and application to the intracellular environment. Biophys. J. 88 (1995) [16] P. Schwille, S. Kummer, A.H. Heikal, W.E. Moerner, W.W. Webb, Fluorescence correlation spectroscopy reveals fast optical excitation-driven intramolecular dynamics of yellow fluorescent proteins. PNAS 97 (2000) [17] Michael Prummer, Christian Hübner, Beate Sick, Bert Hecht, Alois Renn, Urs P. Wild, Single-Molecule Identification by Spectrally and Time-Resolved Fluorescence Detection. Anal. Chem. 2000, 72, [18] J. Schaffer, A. Volkmer, C. Eggeling, V. Subramaniam, C. A. M. Seidel, Identification of single molecules in aqueous solution by time-resolved anisotropy. Journal of Physical Chemistry A, 103 (1999)
42 [19] P.T.C. So, T. French, E. Gratton, A frequency domain microscope using a fast-scan CCD camera. Proc. SPIE 2137 (1994) [20] M. Straub, S. W. Hell, Fluorescence lifetime three-dimensional microscopy with picosecond precision using a multifocal multiphoton mocroscope. Appl. Phys. Lett. 73 (1998) [21] A. Squire, P.J. Verveer, P.I.H. Bastiaens: Multiple frequency fluorescence lifetime imaging microscopy. J. Microsc. 197, (2000). [22] M.A. Neil, A. Squire, R. Juskaitas, P.I. Bastiaens, T. Wilson, Wide-field fluorescence microscopy with laser illumination. J. Microsc. 197 (2000) 1-4 [23] M.J. Cole, J.Siegel, R. Dowling, M.J. Dayel, D. Parsons-Karavassilis, P.M. French, M.J. Lever, L.O. Sucharov, M.A. Neil, R. Juskaitas, T. Wilson, Time-domain whole-field lifetime imaging with optical sectioning. J. Microsc. 203 (2001) [24] Betzig, E., Trautmann, J.K., Near-field optics: Microscopy, spectroscopy and surface modification beyond the diffraction limit. Science 257, [25] Betzig, E., Trautmann, J.K.,Harris, T.D., Weiner, J.S., Kostelak, R.L., Breaking the diffraction barrier: Optical microscopy on a nanometric scale. Science 251 (1991) [26] Dunn, R.C. Near-field scanning optical microscopy. Chem. Rev. 99 (1999) [27] Hollars, C.W., Dunn, R.C., Submicron fluorescence, topology, and compliance measurements of phase-separated lipid monolayers using tapping-mode near-fiel scanning optical microscopy. J. Phys. Chem. B. 101, [28] Kirsch, A.K., Subramaniam, V., Jenei, A., Jovin, T.M., Fluorescence Resonance transfer detected by scanning nearfield optical microscopy. J. Microsc. 194 (1999) [29] Femtolight series fiber lasers, IMRA America Inc., [30] Pulsed diode lasers, PicoQuant GmbH, [31] BDL-450 picosecond diode laser. [32] BHL-250 pulsed diode lasers. [33] M. Kress, Th. Meier, T. A. A. El-Tayeb, R. Kemkemer, R. Steiner, A. Rück, Short-pulsed diode lasers as an excitation source for time-resolved fluorescence applications and confocal laser scanning microscopy in PDT, Proc. SPIE 4431(2001) [33a] A. Rück, F. Dolp, C. Happ, R. Steiner, M. Beil, Fluorescence lifetime imaging (FLIM) using ps pulsed diode lasers in laser scanning microscopy. Proc. SPIE (2003) [34] Hidehiro Kume (Chief Editor), Photomultiplier Tube, Hamamatsu Photonics K.K., 1994 [35] SPCM-AQR series. [36] S. Cova, S. Lacaiti, M.Ghioni, G. Ripamonti, T.A. Louis, 20-ps timing resolution with single-photon avalanche photodiodes, Rev. Sci. Instrum. 60, 1989, [37] M. Nagorni, S. W. Hell, 4Pi-confocal microscopy provides three-dimensional images of the microtubule network with 100- to 150-nm resolution. J. of Structural Biology 123 (1998) [38] Ballew, R.M., Demas, J.N., An error analysis of the rapid lifeetime determination method for the evaluation of single exponential decays. Anal. Chem. 61 (1989) [39] K. Carlsson, J.P. Philip, Theoretical Investigation of the Signal-to-Noise ratio for different fluorescence lifetime imaging techniques. Proc. SPIE (2002) [40] J. Widengreen, R. Rigler, Mechanisms of photobleaching investigated by fluorescence correlation spectroscopy. Bioimaging 4 (1996) [41] A.A. Heikal, W.W. Webb, One- and two-photon time-resolved fluorescence spectroscopy of selected fluorescent markers: photobleaching, triple-, and singlet-state dynamics. Biophys. J. 73 (1999) 260 [42 E.J. Sánchez, L. Novotny, G.R. Holtom, X.S. Xie. Room-Temperature fluorescence imaging and spectroscopy of single molecules by two-photon fluorescence. J. Phys. Chem. A 101 (1997) [43] G.H. Patterson, D.W. Piston, Photobleaching in two-photon exciatation microscopy. Biophys. J. 78 (2000)
43 [44]G. J. Brakenhoff, M. Müller, R.I. Grauharali, Analysis of efficiency of two-photon versus single-photon absorption for fluorescence generation in biological objects. J. Microsc. 183 (1996) [45] Hopf, A., Neher, E., Highly nonlinear Photodamage on two-photon fluorescence microscopy. Biophysical Journal 80 (1002) [46] K. König, P.T.C. So, W.W. Mantulin, B.J. Tromberg, E. Gratton, Two-Photon excited lifetime imaging of autofluorescence in cells during UVA and NIR photostress. J. Microsc. 183, [47] K. Koenig, T.W. Becker, P. Fischer, I. Riemann, K.-J. Halbhuber, Pulse-length dependence of cellular response to intense near-infrared pulses in multiphoton microscopes. Opt. Lett. 24 (1999) [48] J. Bewesdorf, R. Pick, S. W. Hell, Multifocal multiphoton microscopy. Opt. Lett. 23 (1998) [49] A.H. Buist, M. Müller, J. Squier, G.J. Brakenhoff, Real time two-photon absorption microscopy using multi-point excitation. Journal of Microscopy 192 (1998) [50] P. Urayama, J.A. Beamish, F.K. Minn, E.A. Hamon, M.-A. Mycek, A UV fluorescence lifetime imaging microscope to probe endogenous cellular fluorescence. CLEO 2002, Technical Digest, CTh062 [51] Pico Star Camera, [52] K. Carlsson, A. Liljeborg, Simultaneous confocal lifetime imaging of multiple fluorophores using the intensitymodulated multiple-wavelength scanning (IMS) technique. J. Microsc. 191 (1998) [53] K. Carlsson, A. Liljeborg, Confocal fluorescence microscopy using spectral and lifetime information to simultaneaously record four fluorophores with high channel separation. J. Microsc. 185 (1997) [54] P.T.C. So, T. French, W.M. Yu, K.M. Berland, C.Y. Dong, E. Gratton, Time-resolved fluorescence microscopy using two-photon excitation. Bioimaging 3 (1995) [55] P.T.C. So, T. French, E. Gratton, A frequency domain microscope using a fast-scan CCD camera. Proc. SPIE 2137 (1994) [56] A. Squire, P.J. Verveer, P.I.H. Bastiens: Multiple frequency fluorescence lifetime imaging microscopy. J. Microsc. 197, (2000). [57] E.P. Buurman, R. Sanders, A. Draaijer, H.C. Gerritsen, J.J.F. van Veen, P.M. Houpt, Y.K. Levine, Fluorescence lifetime imaging using a confocal laser scanning microscope. Scanning 14, (1992). [58] J. Sytsma, J.M. Vroom, C.J. de Grauw, H.C. Gerritsen, Time-gated fluorescence lifetime imaging and microvolume spectroscopy using two-photon excitation. Journal of Microscopy, 191 (1998) [59] H7422 data sheet, Hamamatsu Photonics, www hamamatsu.com [60] R3809U data sheet, Hamamatsu Photonics, www hamamatsu.com [61] Scully, A.D., Ostler, R.B., Phillips, D., O Neill, P.O., Townsend, K.M.S., Parker, A.W., McRobert, A.J., Application of fluorescence lifetime imaging microscopy to the investigation of intracellular PDT mechanisms. Bioimaging 5 (1997) 9-18 [62] D.V. O Connor, D. Phillips, Time Correlated Single Photon Counting, Academic Press, London 1984 [63] SPC-134 through SPC-730 TCSPC Modules, Operating Manual and TCSPC Compendium. Becker & Hickl GmbH, [64] W. Becker, H. Stiel, E. Klose, Flexible Instrument for time-correlated single photon counting, Rev. Sci. Instrum. 62 (1991) [65] I. Bugiel, K. König, H. Wabnitz, Investigations of cells by fluorescence laser scanning microscopy with subnanosecond resolution. Lasers in the Life Sciences 3 (1989) [66] W. Becker, A. Bergmann, H. Wabnitz, D. Grosenick, A. Liebert, High count rate multichannel TCSPC for optical tomography. Proc. SPIE 4431, (2001) [67] W. Becker, A. Bergmann, K. Koenig, U. Tirlapur, Picosecond fluorescence lifetime microscopy by TCSPC imaging. Proc. SPIE 4262 (2001) [68] Wolfgang Becker, Klaus Benndorf, Axel Bergmann, Christoph Biskup, Karsten König, Uday Tirplapur, Thomas Zimmer, FRET Measurements by TCSPC Laser Scanning Microscopy, Proc. SPIE 4431(2001)
44 [69] Wolfgang Becker, Axel Bergmann, Georg Weiss, Lifetime Imaging with the Zeiss LSM-510. Proc. SPIE 4620 (2002) [70] K. Koenig, C. Peuckert, I. Riemann, U. Wollina, Optical tomography of human skin with picosecond time resolution using intense near infrared femtosecond laser pulses, Proc. SPIE [71] S. Ameer-Beg, P.R. Barber, R. Locke, R.J. Hodgkiss, B. Vojnovic, G.M. Tozer, J. Wilson, Application of multiphoton steady state and lifetime imaging to mapping of tumor vascular architecture in vivo. Proc. SPIE 4620 (2002) [72a] Wolfgang Becker, Axel Bergmann, Christoph Biskup, Thomas Zimmer, Nikolaj Klöcker, Klaus Benndorf, Multiwavelength TCSPC lifetime imaging. Proc. SPIE 4620 (2002) [72b] Wolfgang Becker, Axel Bergmann, Christoph Biskup, Laimonas Kelbauskas, Thomas Zimmer, Nikolaj Klöcker, Klaus Benndorf, High resolution TCSPC lifetime imaging. Proc. SPIE (2003) [73] A. Schönle, M. Glatz, S. W. Hell, Four-dimensional multiphoton microscopy with time-correlated single photon counting. Appl. Optics 39 (2000) [74] S. Jakobs, V. Subramaniam, A. Schönle, Th. Jovin, S.W. Hell, EGFP and DsRed expressing cultures of escherichia coli imaged by confocal, two-photon and fluorescence lifetime microscopy. FEBS Letters 479 (2000) [75] D. Schweitzer, A. Kolb, M. Hammer, E. Thamm, Tau-mapping of the autofluorescence of the human ocular fundus. Proc. SPIE Vol. 4164, [75b] D. Schweitzer, A. Kolb, M. Hammer, E. Thamm, Basic investigations for 2-dimensional time-resolved fluorescence measurements at the fundus. International Ophthalmology 23 (2001) [76] HRT-41, HRT-81, HRT-82 Routing Devices, Operating Manual. Becker & Hickl GmbH, [77] PML Channel Detector Head, Operating Manual. Becker & Hickl GmbH, [78] E-S. Kwak, T.J.Kang, A.A. Vanden Bout, Fluorescence lifetime imaging with near-field scanning optical microscopy. Anal. Chem. 73 (2001) [79] W. Hartmann, F. Bernhard, Fotovervielfacher und ihre Anwendung in der Kernphysik. Akademie-Verlag Berlin 1957 [80] M. Köllner, J. Wolfrum, How many photons are necessary for fluorescence-lifetime measurements? Phys. Chem. Lett. 200 (1992) [81] Gerritsen, H.C., Asselbergs, M.A.H., Agronskaia, A.V., van Sark, W.G.J.H.M., Fluorescence lifetime imaging in scanning microscopes: acquistition speed, photon economy and lifetime resolution. J. Microsc. 206 (2002) [82] L. Kelbauskas, W. Dietel, Internalization of aggregated photosensitizers by tumor cells: Subcellular time-resolved fluorescence spectroscopy on derivates of pyropheophorbide-a ethers and chlorin e6 under femtosecond one- and two-photon excitation. Photochem. Photobiol. 76 (2002)
45 Time-Correlated Single Photon Counting Module SPC-140 bh s multi-dimensional TCSPC technique High-speed on-board data acquisition Multi-detector capability Works at any scan rate of CLSMs or MPLSMs Photon distribution modes and time-tag mode Picosecond resolution Ultra-high sensitivity Time channel width down to 813 fs Lifetime image size up to 1024 x 1024 pixels Steady-state image size up to 2048 x 2048 pixels Electrical time resolution down to 8 ps fwhm / 4 ps rms Reversed start/stop: Laser repetition rates up to 150 MHz Total useful recorded count rate up to 5 MHz Dead time 100 ns, saturated count rate 10 MHz Conventional fluorescence lifetime experiments Picosecond fluorescence lifetime imaging Fluorescence correlation spectroscopy Transient fluorescence lifetime phenomena 0.75 Lifetime, ns 2.25 Becker & Hickl GmbH Nahmitzer Damm Berlin, Berlin Tel. +49 / 30 / Fax. +49 / 30 / [email protected] www becker-hickl com US Representative: Boston Electronics Corp [email protected] www boselec.com UK Representative: Photonic Solutions PLC sales@psplc com www psplc com Covered by patents DE and DE
46 Photon Channels Principle Constant Fraction Discriminator (CFD) Time Resolution (FWHM / RMS, electr.) 8 ps / 5 ps Opt. Input Voltage Range - 50 mv to - 1 V Min. Input Pulse Width 400 ps Lower Threshold - 20 mv to mv Upper Threshold - Zero Cross Adjust mv to mv Synchronisation Channels Principle Constant Fraction Discriminator (CFD) Opt. Input Voltage Range - 50 mv to - 1 V Min. Input Pulse Width 400 ps Threshold - 20 mv to -500 mv Frequency Range 0 to 200 MHz Frequency Divider Zero Cross Adjust -100 mv to mv Time-to-Amplitude Converters / ADCs Principle Ramp Generator / Biased Amplifier TAC Range 50 ns to 2 us Biased Amplifier Gain 1 to 15 Biased Amplifier Offset 0 to 100% of TAC Range Time Range incl. Biased Amplifier 3.3 ns to 2 us min. Time / Channel 813 fs ADC Principle 50 ns Flash ADC with Error Correction Diff. Nonlinearity < 0.5% rms, typ. <1% peak-peak SPC-140 Data Acquisition (Histogram Mode) Method on-board multi-dimensional histogramming process Dead Time 100ns, independent of computer speed Saturated Count Rate 10 MHz Useful count rate 5 MHz Time channels / Curve or pixel max. Scanning Area per TCSPC channel 32x32 64x x x x x x2048 max. Counts / Time Channel Overflow Control none / stop / repeat and correct Collection Time 0.1 us to s Display Interval Time 10ms to 1000 s Repeat Time 0.1 us to 1000 s Sequential recording Programmable Hardware Sequencer Synchronisation with scanning pixel, line and frame clocks from scanning microscope Count Enable Control 1 bit TTL Experiment Trigger TTL Data Acquisition (FIFO / Time-Tag Mode) Method Time-tagging of individual photons and continuous writing to hard disk Dead Time 100 ns Output Data Format (ADC / Macrotime / Routing) 12 / 12 / 3 FIFO buffer Capacity (photons) Macro Timer Resolution, internal clock 50ns, 12 bit Macro Timer Resolution, clock from SYNC input 10ns to 100ns, 12 bit Curve Control (external Routing) 4 bit TTL Count Enable Control 1 bit TTL Operation Environment Computer System PC Pentium Bus Connectors PCI Used PCI Slots 4 Total power Consumption approx. 15 W from +5V, 0.7 W from +12V Dimensions Single-slot PCI card, 225 mm x 125 mm Related Products Simple-Tau compact TCSPC systems, detectors, detector / shutter / beamsplitter assemblies, multichannel detector assemblies, Detector/Shutter Controllers, Preamplifiers, ps Diode Lasers. Please see also SPC-134, SPC-630, SPC-830 time-correlated single photon counting modules, gated photon counters and multiscalers. Please download or call for individual data sheets and manuals. For details please see The bh TCSPC Handbook, available on Becker & Hickl GmbH Nahmitzer Damm Berlin, Berlin Tel. +49 / 30 / Fax +49 / 30 / [email protected] US Representative: Boston Electronics Corp [email protected] Tel: (800) or (617) Fax: (617) UK Representative: Photonic Solutions PLC sales@psplc com com Tel: Fax
47 The TCSPC Microscopy Solution SPC-830 High Resolution Time-Correlated Single Photon Counting Imaging and FCS Module for Laser Scanning Microscopes i Complete picosecond imaging system on single PC board i Picosecond resolution i Ultra-high sensitivity i Multi detector capability i High-speed on-board data acquisition i Works at any scanning speed of microscope i High resolution picosecond lifetime imaging i FRET imaging i High-resolution steady state imaging i Single-point time-lapse lifetime analysis i FCS, FIDA, FILDA, BIFL measurement i Time channel width down to 813 fs i Image size up to 4096 x 4096 pixels i Electrical time resolution down to 8 ps fwhm / 4 ps rms i Reversed start/stop: Laser repetition rates up to 200 MHz i Useful detector count rate up to 8 MHz - dead time 125 ns i Active and passive scanning control i Software versions for windows 95 / 98 / 2000 / NT 0.3 Lifetime, ns 1.2 CFP/YFP FRET 0.5 FRET Intensity Becker & Hickl GmbH Nahmitzer Damm Berlin, Berlin Tel. +49 / 30 / Fax. +49 / 30 / [email protected] US Representative: Boston Electronics Corp [email protected] UK Representative: Photonic Solutions PLC [email protected] Covered by patents DE and DE
48 The TCSPC Microscopy Solution SPC-830 Photon Channel Principle Time Resolution (FWHM / RMS, electr.) Opt. Input Voltage Range Min. Input Pulse Width Lower Threshold Zero Cross Adjust Constant Fraction Discriminator 7 ps / 4 ps - 50 mv to - 1 V 400 ps - 20 mv to mv mv to mv Synchronisation Channel Principle Constant Fraction Discriminator Opt. Input Voltage Range - 50 mv to - 1 V Min. Input Pulse Width 400 ps Threshold - 20 mv to -500 mv Frequency Range 0 to 200 MHz Frequency Divider Zero Cross Adjust -100 mv to mv Time-to-Amplitude Converter / ADC Principle Ramp Generator / Biased Amplifier TAC Range 50 ns to 2 us Biased Amplifier Gain 1 to 15 Biased Amplifier Offset 0 to 100% of TAC Range Time Range incl. Biased Amplifier 3.3 ns to 2 us min. Time / Channel 813 fs TAC Window Discriminator Any Window inside TAC Range ADC Principle 50 ns 12 bit Flash ADC with Error Correction Diff. Nonlinearity (dith width 1/8, 90% of TAC range) < 0.5% rms, typically <1% peak-peak Data Acquisition, Histogram Modes Method on-board 4-dimensional histogramming process over t, x, y, and detector channel number Dead Time 125ns, independent of computer speed Saturated Count Rate / Useful Count Rate 8 MHz / 4 MHz Number of Time Channels / Pixel IImage Resolution (pixels), 1 Detector Channel 4096 x x x x x x x 64 IImage Resolution (pixels), 4 Detector Channels 2048 x x x x x x x 32 IImage Resolution (pixels), 16 Detector Channels 1024 x x x x x x x 16 Counts / Time Channel Counts / Time Channel ( Single mode, repeat and acquire) Overflow Control none / stop / repeat and acquire Collection Time (per curve or per pixel) 100 ns to 1000 s Display Interval Time 10ms to 1000 s Repeat Time 0.1 ms to 1000 s Curve Control (Internal Routing / Scan Sync In Mode) up to 262,144 decay curves Routing Control / Detector Channels 14 bit TTL / Count Enable Control 1 bit TTL Control Signal Latch Delay 0 to 255 ns Experiment Trigger TTL Data Acquisition, FIFO/Time-Tag Modes Method Time-tagging of individual photons and continuous writing to disk Macro Time Resolution 50 ns ADC Resolution / No. of Time Channels 12 bit / 4096 Dead Time 150 ns Output Data Format (ADC / Macrotime / Routing) 12 / 12 /4 FIFO buffer Capacity (photons) 8 million photons Multi Module Systems Number of modules operable parallel 4 Operation Environment Computer System PC Pentium Bus Connector PCI Power Consumption approx. 20 W at +5V, 0.7 W at +12V Dimensions 312 mm x 122 mm x 28 mm Related Products and Accessories Detector Heads (MCPs, PMTs), Multichannel Detector Heads, Routing Devices for Multichannel Measurements, Preamplifiers, PIN and Avalanche Photodiode Modules, ps Diode Lasers, Adapter Cables for Scanning Microscopes. SPC-600/630 TCSPC modules for single molecule and correlation spectroscopy, SPC-700/730 and SPC-144 for imaging and SPC-134 for optical tomography. Please downlaod or call for individual data sheets. To control detectors and shutters please see DCC-100 detector controller. Please visit our web site to download the manual, the device software and application notes. Becker & Hickl GmbH Nahmitzer Damm Berlin, Berlin Tel. +49 / 30 / Fax +49 / 30 / iwww.becker-hickl.com [email protected] Boston Electronics Corporation 91 Boylston Street, Brookline. Massachusetts USA Tel: (800) or (617) , Fax: (617) [email protected]
49 The TCSPC Imaging Package SPC-144 Four-Channel Time-Correlated Single Photon Counting FLIM Module for Laser Scanning Microscopes Four fully parallel TCSPC imaging channels Picosecond resolution Ultra-high sensitivity Multi-detector capability in all four channels High-speed on-board data acquisition Works at any scanning speed of CLSMs or MPLSMs Time channel width down to 813 fs Lifetime image size up to 1024 x 1024 pixels Steady-state image size up to 2048 x 2048 pixels Electrical time resolution down to 8 ps fwhm / 4 ps rms Reversed start/stop: Laser repetition rates up to 150 MHz Total useful recorded count rate up to 20 MHz Dead time 100 ns Multi-wavelength picosecond lifetime imaging FRET imaging FCS, FIDA, FILDA, BIFL High-resolution steady state imaging Single-point time-lapse lifetime analysis 0.75 Lifetime, ns 2.25 Becker & Hickl GmbH Nahmitzer Damm Berlin, Berlin Tel. +49 / 30 / Fax. +49 / 30 / [email protected] www becker-hickl com US Representative: Boston Electronics Corp [email protected] www boselec.com UK Representative: Photonic Solutions PLC sales@psplc com www psplc com Covered by patents DE and DE
50 SPC-144 Photon Channels Principle Constant Fraction Discriminator (CFD) Time Resolution (FWHM / RMS, electr.) 8 ps / 5 ps Opt. Input Voltage Range - 50 mv to - 1 V Min. Input Pulse Width 400 ps Lower Threshold - 20 mv to mv Upper Threshold - Zero Cross Adjust mv to mv Synchronisation Channels Principle Constant Fraction Discriminator (CFD) Opt. Input Voltage Range - 50 mv to - 1 V Min. Input Pulse Width 400 ps Threshold - 20 mv to -500 mv Frequency Range 0 to 200 MHz Frequency Divider Zero Cross Adjust -100 mv to mv Time-to-Amplitude Converters / ADCs Principle Ramp Generator / Biased Amplifier TAC Range 50 ns to 2 us Biased Amplifier Gain 1 to 15 Biased Amplifier Offset 0 to 100% of TAC Range Time Range incl. Biased Amplifier 3.3 ns to 2 us min. Time / Channel 813 fs ADC Principle 50 ns Flash ADC with Error Correction Diff. Nonlinearity < 0.5% rms, typ. <1% peak-peak Data Acquisition (Histogram Mode) Method on-board multi-dimensional histogramming process Dead Time 100ns, independent of computer speed Saturated Count Rate, per TCSPC channel / total 10 MHz / 40 MHz Useful count rate, per TCSPC channel / total 5 MHz / 20 MHz Channels / Curve per TCSPC channel max. Scanning Area per TCSPC channel 16x16 64x x x x x x2048 max. Counts / Time Channel Overflow Control none / stop / repeat and correct Collection Time 0.1 us to s Display Interval Time 10ms to 1000 s Repeat Time 0.1 us to 1000 s Sequential recording Programmable Hardware Sequencer Synchronisation with scanning pixel, line and frame clocks from scanning microscope Count Enable Control 1 bit TTL Experiment Trigger TTL Data Acquisition (FIFO / Time-Tag Mode) Method Time-tagging of individual photons and continuous writing to disk Dead Time 100 ns Output Data Format (ADC / Macrotime / Routing) 12 / 12 / 3 FIFO buffer Capacity (photons) 2 M Macro Timer Resolution, internal clock 50ns, 12 bit Macro Timer Resolution, clock from SYNC input 10ns to 100ns, 12 bit Curve Control (external Routing) 3 bit TTL Count Enable Control 1 bit TTL Operation Environment Computer System PC Pentium Bus Connectors PCI Used PCI Slots 4 Total power Consumption approx. 60 W from +5V, 0.7 W from +12V Dimensions 225 mm x 125 mm x 85 mm Related Products and Accessories Detectors and Detector Modules, Multichannel Detector Heads, Step Motor Controllers, Detector/Shutter Controllers, Preamplifiers, ps Diode Lasers. Also available: SPC-134, SPC-6, -7, -8 time-correlated single photon counting modules, gated photon counters and multiscalers. Please download or call for individual data sheets and manuals. Please visit our web site to download the manual, the device software and application literature. Designed and manufactured by Becker & Hickl GmbH Nahmitzer Damm Berlin, Berlin Tel. +49 / 30 / Fax +49 / 30 / ihttp:// [email protected] US Representative: Boston Electronics Corp [email protected] Tel: (800) or (617) Fax: (617) UK Representative: Photonic Solutions PLC sales@psplc com com Tel: Fax
51 The TCSPC Imaging Package SPC-154 Four-Channel Time-Correlated Single Photon Counting Module Four fully parallel TCSPC channels Picosecond resolution Ultra-high sensitivity Multi-detector capability in all four channels High-speed on-board data acquisition Photon distribution and time-tag modes Image acquisition by synchronisation with ext. scanner Unlimited sequential recording of curves or images Imaging in histogram mode and in time-tag mode Works at any scan rate of CLSMs or MPLSMs Time channel width down to 813 fs Electrical time resolution down to 8 ps fwhm / 4 ps rms Reversed start/stop: Laser repetition rates up to 150 MHz Total saturated count rate 40 MHz Total useful recorded count rate up to 20 MHz Channel dead time 100 ns Multi-wavelength FLIM Double-exponential FLIM Fast-Acquisition FLIM Fast Sequential FLIM Single and double-exponential FRET imaging FCS, FCCS, FIDA, FILDA, BIFL FCS Imaging DOT, static and dynamic brain imaging Transient fluorescence lifetime effects Becker & Hickl GmbH Nahmitzer Damm Berlin, Berlin Tel. +49 / 30 / Fax. +49 / 30 / [email protected] www becker-hickl com US Representative: Boston Electronics Corp [email protected] www boselec.com UK Representative: Photonic Solutions PLC sales@psplc com www psplc com Covered by patents DE and DE
52 SPC-154 Photon Channels Principle Constant Fraction Discriminator (CFD) Time Resolution (FWHM / RMS, electr.) 8 ps / 5 ps Opt. Input Voltage Range - 50 mv to - 1 V Min. Input Pulse Width 400 ps Lower Threshold - 20 mv to mv Upper Threshold - Zero Cross Adjust mv to mv Synchronisation Channels Principle Constant Fraction Discriminator (CFD) Opt. Input Voltage Range - 50 mv to - 1 V Min. Input Pulse Width 400 ps Threshold - 20 mv to -500 mv Frequency Range 0 to 200 MHz Frequency Divider Zero Cross Adjust -100 mv to mv Time-to-Amplitude Converters / ADCs Principle Ramp Generator / Biased Amplifier TAC Range 50 ns to 2 us Biased Amplifier Gain 1 to 15 Biased Amplifier Offset 0 to 100% of TAC Range Time Range incl. Biased Amplifier 3.3 ns to 2 us min. Time / Channel 813 fs ADC Principle 50 ns Flash ADC with Error Correction Diff. Nonlinearity < 0.5% rms, typ. <1% peak-peak Data Acquisition (Histogram Mode) Method on-board multi-dimensional histogramming process Dead Time 100ns, independent of computer speed Saturated Count Rate, per TCSPC channel / total 10 MHz / 40 MHz Useful count rate, per TCSPC channel / total 5 MHz / 20 MHz Channels / Curve per TCSPC channel max. Scanning Area per TCSPC channel 16x16 64x x x x x x2048 max. Counts / Time Channel Overflow Control none / stop / repeat and correct Collection Time 0.1 us to s Display Interval Time 10ms to 1000 s Repeat Time 0.1 us to 1000 s Sequential Recording Programmable Hardware Sequencer Unlimited recording by memory swapping, in curve mode and scan mode Synchronisation with Scanning pixel, line and frame clocks from scanning device Count Enable Control 1 bit TTL Experiment Trigger TTL Data Acquisition (FIFO / Time-Tag Mode) Method Dead Time Output Data Format (ADC / Macrotime / Routing) Output Data Format for Scan Clock Markers (pxl, line, frame) FIFO Buffer Capacity (photons and clock markers) Macro Timer Resolution, internal clock Macro Timer Resolution, clock from SYNC input Curve Control (external Routing) Count Enable Control Time-tagging of individual photons and continuous writing to disk 100 ns 12 bit ADC / 12 bit macro time / 4 bit routing 12 bit macro time / pxl, line, frame 2 M 25 ns, 12 bit 10 ns to 100 ns, 12 bit 4 bit TTL 1 bit TTL Operation Environment Computer System PC Pentium Bus Connectors PCI Used PCI Slots 4 Total power Consumption approx. 60 W from +5V, 0.7 W from +12V Dimensions 240 mm x 130 mm x 85 mm Product Literature W. Becker, The bh TCSPC Handbook. Available on Designed and manufactured by Becker & Hickl GmbH Nahmitzer Damm Berlin, Berlin Tel. +49 / 30 / Fax +49 / 30 / ihttp:// [email protected] US Representative: Boston Electronics Corp tcspc@boselec com Tel: (800) or (617) Fax: (617) UK Representative: Photonic Solutions PLC [email protected] Tel: Fax
53 Multi-Spectral FLIM System MS-FLIM Fluorescence lifetime imaging with spectral resolution Picosecond time resolution Based on BH s multi-dimensional TCSPC technique Ultra-high sensitivity due to simultaneous detection in all time and wavelength channels Adapters for confocal microscopes Adapters for non-descanned outputs of multiphoton microscopes Separation of fluorophores by fluorescence lifetime and spectrum Autofluorescence imaging of tissue ph imaging of tissue FRET experiments Combined Lifetime / SHG imaging The MW-FLIM system is based on a 16-channel multianode PMT detector module in combination with a polychromator and BH s proprietary multi-dimensional TCSPC technique. A fibre bundle is used to transfer the light from the microscope into the entrance slit of the polychromator. Due to the large light collection area a high efficiency is obtained both for confocal detection and for non-descanned (direct) detection in multiphoton microscopes. Typical applications are multi-spectral autofluorescence imaging in deep tissue, ph imaging in tissue, combined FLIM and SHG imaging, and investigation of protein interaction by FRET. Protein interaction in live cells: FRET, Cerulean-YFP Donor Acceptor Lifetime of donor Fraction of FRET Efficiency Cerulean YFP interacting proteins Becker & Hickl GmbH Nahmitzer Damm Berlin, Germany Tel Fax info@becker-hickl com www becker-hickl com US Representative: Boston Electronics Corp 91 Boylston Street, Brookline. Massachusetts USA Tel: (800) or (617) Fax: (617) com [email protected] UK Representative: Photonic Solutions PLC [email protected]
54 Multi-Spectral FLIM System MS-FLIM Part List M-SHUT field lens and shutter assembly 1) MW-FLIM fibre adapter LOT MS125 spectrograph PML-16-0 (300 to 600 nm) or PML-16-1 (300 to 800 nm) 16 channel PMT module, with MS125 adapter High-voltage power supply for PML-16 SPC-830 TCSPC module 2) or Simple-Tau 830 stand- DCC-100 detector controller 2) alone TCSPC system 3) SPC-830 standard cable set SPC-830 scan control cable 1) SPCImage FLIM data analysis software 1) please specify microscope type and configuration in your order 2) PC cards, to be inserted in a Pentium PC 3) Laptop based stand-alone system, contains SPC-830 and DCC-100 Wavelength range and resolution Grating Primary wavelength region Width of recorded wavelength Blaze Wavelength Part No. adjustable by set screw 4) interval, channel 1 to nm 300 nm 500 nm (standard) nm 200 nm 400 nm nm 100 nm 350 nm 4) for PML-16-1, may vary due to transmission range of microscope optics The setup employs BH s multi-dimensional TCSPC technique featuring multiwavelength capability, high count rate, near-ideal counting efficiency, low differential nonlinearity, and ultra-high timeresolution. It contains the usual building blocks (CFDs, TAC, ADC) in the reversed start-stop configuration together with a scanning interface and a large histogram memory integrated on a single PC board. For each photon the TCSPC module determines the time within the fluorescence decay function, t, the wavelength, λ, and the location within the scanning area, x and y. These values are used to address a memory in which the events are accumulated. Thus, in the memory the distribution of the photon density over X, Y, λ, and t builds up. With a 16-channel detector, the result contains 16 data sets for different wavelength, each containing a large number of images for different time in the fluorescence decay curve. The recording process runs at any scan rate, including ultra-high rates of resonance scanners. from Polychromator Channel Channel register n Channel / Wavelength Detector PML-16 Time Timing Measurement CFD Start TAC ADC t Time within decay curve Stop CFD from Laser Frame Sync Line Sync Pixel Clock from Microscope Counter Y Scanning Interface Counter X MW-FLIM: Principle of data acquisition For more information please download or call for y x Histogram Memory Detector channel 1 Histogram Memory Detector channel... Location within scanning area Histogram Memory Detector channel... Covered by patents DE and DE Histogram Memory Detector channel 16 SPC-140 through SPC-830 TCSPC modules. Manual and TCSPC compendium SPC-830 data sheet PML-16 data sheet, PML-16 manual Becker & Hickl GmbH Nahmitzer Damm Berlin, Germany Tel Fax [email protected] US Representative: Boston Electronics Corp 91 Boylston Street, Brookline. Massachusetts USA Tel: (800) or (617) Fax: (617) com [email protected] UK Representative: Photonic Solutions PLC [email protected]
55 Lifetime Upgrade Kit for Zeiss LSM-510 Fluorescence lifetime imaging with ps resolution Two-photon excitation Non descanned detection Ultra-high sensitivity due to TCSPC technique Zoom and image rotation functions of LSM-510 applicable FRET experiments Fluorescence quenching New fluorescence probes based on lifetime changes Separation of fluorophores by lifetime Autofluorescence CFP/YFF FRET in HEK Cell Autofluorescence of human skin 0.5 FRET Intensity Lifetime, ns 2.5 The setup employs an advanced multi-dimensional TCSPC technique featuring high count rate, near-ideal counting efficiency, and multiwavelength capability. It contains the usual building blocks (CFDs, TAC, ADC) in the reversed start-stop configuration together with a scanning interface and a large histogram memory integrated on a single PC board. For each photon the TCSPC module determines the time within the fluorescence decay function and the location within the scanning area. These values are used to address a histogram memory in which the events are accumulated. Thus, in the memory the distribution of the photon density over X, Y, and the time within the fluorescence decay function builds up. The result can be interpreted as a two-dimensional (X, Y) array of fluorescence decay curves or as a sequence of fluorescence images for different times (t) after the excitation pulse. Time Measurement Start CFD From PMT TAC ADC Stop CFD From Laser Frame Sync Line Sync Pixel Clock Scanning Interface From Scanning Unit Time within decay curve Y Beam Location X Y t Histogram Memory Stack of images for subsequent times in decay curves X Requirements to LSM-510 Microscope LSM-510 NLO with Ti:Sa Laser Axiovert or Axioplan version NDD switch box installed Becker & Hickl GmbH Nahmitzer Damm Berlin, Germany Tel Fax [email protected] US Representative: Boston Electronics Corp 91 Boylston Street, Brookline. Massachusetts USA Tel: (800) or (617) , Fax: (617) [email protected]
56 LSM 510 NLO FLIM Upgrade Kit SPC-830 TCSPC module DCC-100 detector controller Detector Options PMC-100 / M-SHUT-Z-NDD H / M-SHUT-Z-NDD R3809U / M-SHUT-Z-NDD Detector / shutter assembly Detector / shutter assembly Detector / shutter assembly Cooled PMT Cooled GaAsP PMT Multichannel plate PMT IRF width 150 to 180 ps IRF width 300 to 350 ps IRF width < 30 ps For lifetimes down to 100 ps For lifetimes down to 200 ps For lifetimes down to 20 ps Dark counts typ. 20 to 50 s -1 Dark counts typ. 20 to 80 s -1 dark counts typ. 100 to 500 s -1 PMC-0: 300 to 650 nm 300 to 690 nm, ultra-high sensitivity R3809U-52: 180 to 650 nm PMC-1: 300 to 820 nm R3809U-50: 180 to 820 nm Length 135 mm 1) Length without cables 195 mm 1) Length without cables 195 mm 1) Gain control via DCC-100 Gain control via DCC-100 Gain control via DCC-100 Overload shutdown via DCC-100 Overload shutdown via DCC-100 Overload shutdown via DCC-100 no external components HFAC-26-2 preamplifier HFAD preamplifier FuG HCN A HV power supply 1) Depending on the microscope configuration, space contstaints may preclude the use at one of the detector ports of the NDD switch box Dual Wavelength Operation HRT-41 Router Simultaneous operation of two PMC-100, H7422, or R3809U detectors attached to the outputs of the Zeiss NDD switch box Uses BH s patented simultaneously recording multi-detector TCSPC principle FLIM Data Analysis SPCImage Data Analysis Single and multi exponential decay analysis Lifetime in pixels displayed as colour Lifetime distribution FRET intensity by doubleexponential analysis of donor decay function For more information please download or call for SPC-134 through SPC-830 TCSPC modules, Manual and TCSPC compendium Upgrading TCSPC laser scanning microscopes with the SPC-730 and SPC-830 TCSPC imaging modules W. Becker, A. Bergmann, Lifetime imaging techniques for optical microscopy W. Becker, A. Bergmann, Detector assemblies for picosecond microscopy DCC-100 manual SPCImage manual SPC-830, DCC-100, PMC-100, HFAC-26 and HFAD-26 data sheets Becker & Hickl GmbH Tel Fax [email protected]
57 FLIM Upgrade Kits for Olympus FV1000 Fluorescence lifetime imaging with ps resolution Excitation by picosecond diode laser Confocal detection Multi-dimensional TCSPC technique Single- or dual channel detection Multi-wavelength lifetime imaging Excellent sensitivity and time-resolution Full range of zoom and image rotation functions Works at any scan rate Separation of fluorophores by lifetime Autofluorescence FRET experiments, protein-protein interaction Imaging of ph, ion concentrations, or oxygen concentration The system is based on a picosecond diode laser of 405 nm, 440 nm or 473 nm wavelength with highefficiency single-mode fibre coupling, a single-, dual-, or multi-wavelength detector module, and BH s proprietary multi-dimensional TCSPC technique. The pulsed laser light is fed into the microscope via a standard single-mode optical fibre. A high speed detector assembly is attached to the optical output of the scan head. Both directly coupled and fibre-coupled versions are available. A large variety of detector modules is available for single-wavelength, dualwavelength, or multispectral detection in 16 wavelength channels. The signals of all detector channels are recorded simultaneously by multidimensional TCSPC, resulting in excellent efficiency and time resolution. Typical applications are multispectral autofluorescence imaging of tissue, ph imaging in tissue, combined FLIM and SHG imaging, and investigation of protein interaction by FRET. Plant tissue, Mean lifetime of double-exponential decay. Courtesy of Dr. Neumann, Life & Brain, Bonn, Germany The laser is a joint product of BH and LASOS TCSPC technique covered by patents DE and DE Becker & Hickl GmbH Nahmitzer Damm Berlin, Germany Tel Fax [email protected] LASOS Lasertechnik GmbH Carl-Zeiss-Promenade Jena, Germany Tel Fax [email protected] UK Representative: Photonic Solutions PLC Tel [email protected] US Representative: Boston Electronics Corp 91 Boylston Street, Brookline. Massachusetts USA Tel: (800) or (617) Fax: (617) tcspc@boselec com,
58 FLIM Upgrade Kits for Olympus FV1000 Computer Options TCSPC cards, to be placed in any Pentium computer Laptop-based systems, fully installed SPC-830 TCSPC module DCC-100 detector controller Detector Options A wide selection of detector assemblies is available. The PMC-100 is recommended for standard applications, the H7422 for combined FLIM and FCS experiments. The R3809U is recommneded for ultra-fast FLIM down to lifetimes of 30 ps. Due to its fast and clean response the R3809U is the ultimate solution for FRET imaging. All these detectors are coupled directly to the scan head, thus avoiding coupling loss or pulse dispersion in optical fibres. Dual-detector beamsplitter units are available for all these detectors. Multi-wavelength detection in 16 wavelength channels is obtained by using the PML-16 / MW-FLIM unit. PMC-100 / M-SHUT H / M-SHUT R3809U / M-SHUT R3809U / M-SHUT-DUAL PML-16 / MW-FLIM Cooled PMT Cooled GaAsP PMT Multichannel plate PMT Two multichannel plate PMTs Spectrograph and 16 channel multi-anode PMT IRF width 150 to 180 ps IRF width 300 to 350 ps IRF width < 30 ps Simultaneous detection Simultaneous detection in 16 wavelength channels For lifetimes down to 100 ps For lifetimes down to 200 ps For lifetimes down to 50 ps in two wavelength intervals For lifetimes down to 100 ps PMC-0: 340 to 650 nm 340 to 690 nm, ultra-high sensitivity R3809U-52: 340 to 650 nm R3809U-52: 340 to 650 nm PML-16-0: 340 to 650 nm PMC-1: 340 to 820 nm R3809U-50: 340 to 820 nm R3809U-50: 340 to 820 nm PML-16-1: 340 to 820 nm FLIM Data Analysis Other combinations: Please call bh SPCImage Data Analysis Single- and multi-exponential decay analysis Lifetime in pixels displayed as colour Lifetime distribution Separation of interacting and non-interacting donor fraction of FRET True FRET intensity and fraction of interacting proteins For more information please download or call for W. Becker, The TCSPC Handbook, Becker & Hickl GmbH 2005 W. Becker, A. Bergmann, Detector assemblies for picosecond microscopy DCC-100 manual SPCImage manual Data sheets: SPC-830, DCC-100, PMC-100, MW-FLIM, Simple-Tau, BDL-405-SM Supplementary FLIM Literature W. Becker, Adcanced time-correlated single-photon counting techniques. Springer, Berlin, Heidelberg, New York, 2005 Becker & Hickl GmbH Nahmitzer Damm Berlin, Germany Tel Fax [email protected] LASOS Lasertechnik GmbH Carl-Zeiss-Promenade Jena, Germany Tel Fax [email protected] UK Representative: Photonic Solutions PLC Tel [email protected] US Representative: Boston Electronics Corp 91 Boylston Street, Brookline. Massachusetts USA Tel: (800) or (617) Fax: (617) tcspc@boselec com,
59 DCS-120 Confocal Scanning System System Configuration and Options Lasers Scanner Detectors TCSPC Options Scanner Control Available Wavelengths 405 nm, 440 nm, 473 nm Repetition rates 20 MHz, 50 MHz, 80 MHz,, CW Pulse width typ. 60 ps Intensity control, electronical 1:10 Beam correction optics Beam-profile and astigmatism correction Fibre coupling Single-mode, into Point-Source fibre Power delivered into fibre: 405 nm: 1 mw, 440 nm: 0.4 mw, 473 nm: 0.4 mw Multiplexing Pixel by pixel, line by line, or frame by frame Beam blanking During x and y flyback, via bh GVD-120 scan controller Laser inputs Point-Source manipulator, push-and click Laser power regulation, optical Attenuators, 1:1 to 1:50 Laser beam combiner Dichroic Scanner Close-coupled galvano mirrors Main beamsplitter Dichroic 420 nm, dichroic 490 nm, or 80:20 mirror (fixed) Secondary beamsplitter Beamsplitter wheel. Dichroic 510 nm, Dichroic 560 nm, polarising beamsplitter, 100% channel 1, 100% channel 2. Other dichroics on request Pinholes From approx. 0.5 AU to 10 AU 1) Filters Filter sliders, standard filters LP 435, LP 485, BP 480/40, BP535/30, BP 620/60. Other filters on request. Standard PMTs PMC or -20 cooled PMT modules. IRF width 180 ps 2) High-efficiency PMTs H7422P-40 GaAsP PMT modules. IRF width 200 to 350 ps 2) High-speed MCP-PMTs R3809U-50 MCP PMTs, IRF width 70 ps 2) Single-photon APDs id , IRF width 70 ps 2) Multi-wavelength detector Detector control bh MW FLIM detector. Please see individual data sheet. Gain, cooling, overload shutdown. Via bh DCC-100 detector controller, see individual data sheet 1 SPC-830 TCSPC module High-speed, large image size with 1 detector. Multi-wavelength detector 1 SPC HRT-41 router Medium speed acquisition with two detectors 2 SPC-830 TCSPC modules High speed, large image size systems with 2 detectors 1 SPC-150 TCSPC module High-speed medium image size systems with 1 detector Medium speed ultra-large image size systems with 1 detector 2 SPC-150 TCSPC modules High-speed systems with 2 detectors Medium speed ultra-large image size systems with 2 detectors Please see individual data sheets or bh TCSPC Handbook Scan controller bh GVD-120 (single-slot PCI module) Generation of scan signals Hardware, digital signal synthesis Image size 16 x 16 to 2048 x 2048 Max. scan rate, time/frame 128x128: 0.32s, 256x256: 0.6s, 512x512: 1.5s 3) Zoom factor 1:1 to 1:10 4) Beam blanking During flyback, on / off selectable Laser multiplexing Pixel by pixel, line by line, or frame by frame Beam park function any location within scan area Scan control software Integrated in standard SPCM TCSPC software Galvo driver amplifier bh GVP-120 1) depends on microscope lens used 2) Includes pulse width of ps diode laser 3) maximum scan rate depends on zoom factor 4) useful zoom range depends on microscope Related Products SPC-830, SPC-630, SPC-134, SPC-140/144, SPC-150/154 TCSPC modules, DCC-100 Detector controller, BDL-375, -405, -440, -473 picosecond / CW diode lasers, id-100 SPAD modules, PMT detector modules, PML-SPEC and MW FLIM multi-wavelength detection systems. Please download individual data sheets and manuals, or see The bh TCSPC Handbook, available on Becker & Hickl GmbH Nahmitzer Damm Berlin, Berlin Tel. +49 / 30 / Fax +49 / 30 / iwww.becker-hickl.com [email protected] Boston Electronics Corporation 91 Boylston Street, Brookline. Massachusetts USA Tel: (800) or (617) , Fax: (617) [email protected]
60 DCS-120 Confocal Scanning System Confocal Scanner for Fluorescence Lifetime Imaging FLIM upgrade for conventional microscopes Fully confocal Scanning by fast galvano mirrors One or two input channels for bh BDL picosecond diode lasers Laser wavelengths 405 nm, 440 nm, or 473 nm High excitation power by beam-profile-corrected laser couplers One or two detection channels Channel separation by dichroic or polarising beamsplitters Individually selectable pinholes Individually selectable filters High efficiency by direct-coupled detectors PMC-100, H7422 or ultra-fast MCP detector modules 16-channel multi-wavelength detector module Compatible with bh SPC-830, SPC-140, or SPC-150 TCSPC modules Scan control software for Windows 2000, NT and XP High accuracy: Triple-exponential decay Multi-wavelength detection Becker & Hickl GmbH Nahmitzer Damm Berlin, Berlin Tel. +49 / 30 / Fax. +49 / 30 / [email protected] US Representative: Boston Electronics Corp [email protected] UK Representative: Photonic Solutions PLC [email protected] High speed: Chloroplasts, acquisition in 1 second
Recording the Instrument Response Function of a Multiphoton FLIM System
Recording the Instrument Response Function of a Multiphoton FLIM System Abstract. FLIM data analysis in presence of SHG signals or extremely fast decay components requires the correct instrument response
Zeiss 780 Training Notes
Zeiss 780 Training Notes 780 Start Up Sequence Do you need the argon laser, 458,488,514nm lines? No Turn on the Systems PC Switch Turn on Main Power Switch Yes Turn on the laser main power switch and turn
Make Life Easier by Using Modern Features of the SPCM Software
Make Life Easier by Using Modern Features of the SPCM Software Abstract. Over a long period of time the SPCM operating software of the Becker & Hickl TCSPC systems has continuously been upgraded with new
Molecular Spectroscopy
Molecular Spectroscopy UV-Vis Spectroscopy Absorption Characteristics of Some Common Chromophores UV-Vis Spectroscopy Absorption Characteristics of Aromatic Compounds UV-Vis Spectroscopy Effect of extended
Applications of confocal fluorescence microscopy in biological sciences
Applications of confocal fluorescence microscopy in biological sciences B R Boruah Department of Physics IIT Guwahati Email: [email protected] Page 1 Contents Introduction Optical resolution Optical
Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.
Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM. Some limitations (disadvantages) of NSOM A trade-off
Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus
Please do not remove this manual from from the lab. It is available at www.cm.ph.bham.ac.uk/y2lab Optics Introduction Optical fibres are widely used for transmitting data at high speeds. In this experiment,
(Amplifying) Photo Detectors: Avalanche Photodiodes Silicon Photomultiplier
(Amplifying) Photo Detectors: Avalanche Photodiodes Silicon Photomultiplier (no PiN and pinned Diodes) Peter Fischer P. Fischer, ziti, Uni Heidelberg, Seite 1 Overview Reminder: Classical Photomultiplier
CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL
CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL Robert Bagnell 2006 This tutorial covers the following CLSM topics: 1) What is the optical principal behind CLSM? 2) What is the spatial resolution in X, Y,
PMS-300 PMS-400 and PMS-400A 800 MHz Gated Photon Counters / Multiscalers
Becker & Hickl GmbH May 2004 Optimised for Printer HP 4000 TN PS High-performance Photon Counting Becker & Hickl GmbH Nahmitzer Damm 30 12277 Berlin Tel. +49 / 30 / 787 56 32 FAX +49 / 30 / 787 57 34 http://www.becker-hickl.com
A VERYbrief history of the confocal microscope 1950s
Confocal Microscopy Confocal Microscopy Why do we use confocal microscopy? A brief history of the confocal microscope Advantages/disadvantages of a confocal microscope Types of confocal microscopes The
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications Saulius Marcinkevičius Optics, ICT, KTH 1 Outline Optical near field. Principle of scanning near field optical microscope
Two-photon FCS Tutorial. Berland Lab Department of Physics Emory University
Two-photon FCS Tutorial Berland Lab Department of Physics Emory University What is FCS? FCS : Fluorescence Correlation Spectroscopy FCS is a technique for acquiring dynamical information from spontaneous
Module 13 : Measurements on Fiber Optic Systems
Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)
Zecotek S Light Projection Network Marketing
White Paper Zecotek Visible Fiber Laser Platform Enabling the future of laser technology Zecotek Photonics Inc. (TSX- V: ZMS; Frankfurt: W1I) www.zecotek.com is a Canadian photonics technology company
Optical laser beam scanner lens relay system
1. Introduction Optical laser beam scanner lens relay system Laser beam scanning is used most often by far in confocal microscopes. There are many ways by which a laser beam can be scanned across the back
Raman Spectroscopy Basics
Raman Spectroscopy Basics Introduction Raman spectroscopy is a spectroscopic technique based on inelastic scattering of monochromatic light, usually from a laser source. Inelastic scattering means that
A More Efficient Way to De-shelve 137 Ba +
A More Efficient Way to De-shelve 137 Ba + Abstract: Andrea Katz Trinity University UW REU 2010 In order to increase the efficiency and reliability of de-shelving barium ions, an infrared laser beam was
Fundamentals of modern UV-visible spectroscopy. Presentation Materials
Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms
PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. IV Femtosecond Measurements Combined With Near-Field Optical Microscopy - Artyom A.
FEMTOSECOND MEASUREMENTS COMBINED WITH NEAR FIELD OPTICAL MICROSCOPY Artyom A. Astafiev, Semyonov Institute of Chemical Physics, Moscow, Russian Federation. Keywords: diffraction limit nearfield scanning
TOF FUNDAMENTALS TUTORIAL
TOF FUNDAMENTALS TUTORIAL Presented By: JORDAN TOF PRODUCTS, INC. 990 Golden Gate Terrace Grass Valley, CA 95945 530-272-4580 / 530-272-2955 [fax] www.rmjordan.com [web] [email protected] [e-mail] This
Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service
Introduction into Flow Cytometry Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service How does a FACS look like? FACSCalibur FACScan What is Flow Cytometry?
Synthetic Sensing: Proximity / Distance Sensors
Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,
Single Photon Counting Module COUNT -Series
Description Laser Components COUNT series of s has been developed to offer a unique combination of high photon detection efficiency, wide dynamic range and ease of use for photon counting applications.
Lab 9: The Acousto-Optic Effect
Lab 9: The Acousto-Optic Effect Incoming Laser Beam Travelling Acoustic Wave (longitudinal wave) O A 1st order diffracted laser beam A 1 Introduction qb d O 2qb rarefractions compressions Refer to Appendix
Experiment 5. Lasers and laser mode structure
Northeastern University, PHYS5318 Spring 2014, 1 1. Introduction Experiment 5. Lasers and laser mode structure The laser is a very important optical tool that has found widespread use in science and industry,
ZEISS Microscopy Course Catalog
ZEISS Microscopy Course Catalog ZEISS Training and Education Expand Your Possibilities Practical microscopy training has a long tradition at ZEISS. The first courses were held in Jena as early as 1907,
A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine
Chapter 1 A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine This chapter provides a historical foundation of the field of microscopy and outlines the significant
Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...
Confocal Microscopy and Atomic Force Microscopy (AFM) of biofilms A very brief primer... Fundamentals of Confocal Microscopy Based on a conventional fluorescence microscope Fluorescent Microscope Confocal
Physics 441/2: Transmission Electron Microscope
Physics 441/2: Transmission Electron Microscope Introduction In this experiment we will explore the use of transmission electron microscopy (TEM) to take us into the world of ultrasmall structures. This
Problem Set 6 UV-Vis Absorption Spectroscopy. 13-1. Express the following absorbances in terms of percent transmittance:
Problem Set 6 UV-Vis Absorption Spectroscopy 13-1. Express the following absorbances in terms of percent transmittance: a 0.051 b 0.918 c 0.379 d 0.261 e 0.485 f 0.072 A = log P o /P = log1/t = - log T
Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.
Helium-Neon Laser Experiment objectives: assemble and align a 3-mW HeNe laser from readily available optical components, record photographically the transverse mode structure of the laser output beam,
A Guide to Acousto-Optic Modulators
A Guide to Acousto-Optic Modulators D. J. McCarron December 7, 2007 1 Introduction Acousto-optic modulators (AOMs) are useful devices which allow the frequency, intensity and direction of a laser beam
Acousto-optic modulator
1 of 3 Acousto-optic modulator F An acousto-optic modulator (AOM), also called a Bragg cell, uses the acousto-optic effect to diffract and shift the frequency of light using sound waves (usually at radio-frequency).
Avalanche Photodiodes: A User's Guide
!"#$%& Abstract Avalanche Photodiodes: A User's Guide Avalanche photodiode detectors have and will continue to be used in many diverse applications such as laser range finders and photon correlation studies.
Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff
Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff December 2012 Specifying Advanced Plasma Deposited Hard Coated Optical Bandpass and Dichroic Filters. Introduction
Time-Correlated Single Photon Counting
Technical Note Time-Correlated Single Photon Counting Michael Wahl, PicoQuant GmbH The Principle of Time-Correlated Single Photon Counting Time-resolved fluorescence spectroscopy is a powerful analysis
Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale
Nano-Spectroscopy Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale Since its introduction in the early 80 s, Scanning Probe Microscopy (SPM) has quickly made nanoscale imaging an affordable
product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology
product overview family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology scmos knowledge base scmos General Information PCO scmos cameras are a breakthrough
RF Measurements Using a Modular Digitizer
RF Measurements Using a Modular Digitizer Modern modular digitizers, like the Spectrum M4i series PCIe digitizers, offer greater bandwidth and higher resolution at any given bandwidth than ever before.
Real-world applications of intense light matter interaction beyond the scope of classical micromachining.
Dr. Lukas Krainer [email protected] CEO Real-world applications of intense light matter interaction beyond the scope of classical micromachining. 1 Management & Company Company Based in Zürich, Switzerland
Near-field scanning optical microscopy (SNOM)
Adviser: dr. Maja Remškar Institut Jožef Stefan January 2010 1 2 3 4 5 6 Fluorescence Raman and surface enhanced Raman 7 Conventional optical microscopy-limited resolution Two broad classes of techniques
Measuring Laser Power and Energy Output
Measuring Laser Power and Energy Output Introduction The most fundamental method of checking the performance of a laser is to measure its power or energy output. Laser output directly affects a laser s
ING LA PALMA TECHNICAL NOTE No. 130. Investigation of Low Fringing Detectors on the ISIS Spectrograph.
ING LA PALMA TECHNICAL NOTE No. 130 Investigation of Low Fringing Detectors on the ISIS Spectrograph. Simon Tulloch (ING) June 2005 Investigation of Low Fringing Detectors on the ISIS Spectrograph. 1.
Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies
Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies (Ci), where 1 Ci = 3.7x10 10 disintegrations per second.
Fiber Optics: Fiber Basics
Photonics Technical Note # 21 Fiber Optics Fiber Optics: Fiber Basics Optical fibers are circular dielectric wave-guides that can transport optical energy and information. They have a central core surrounded
Flow cytometry basics fluidics, optics, electronics...
Title Flow cytometry basics fluidics, optics, electronics... RNDr. Jan Svoboda, Ph.D. Cytometry and Microscopy Core Facility IMB, CAS, v.v.i Vídeňská 1083 Fluorescence Fluorescence occurs when a valence
Characteristic and use
. Basic principle A PSD basically consists of a uniform resistive layer formed on one or both surfaces of a high-resistivity semiconductor substrate, and a pair of electrodes formed on both ends of the
Extended spectral coverage of BWO combined with frequency multipliers
Extended spectral coverage of BWO combined with frequency multipliers Walter C. Hurlbut, Vladimir G. Kozlov, Microtech Instruments, Inc. (United States) Abstract: Solid state frequency multipliers extend
hsfc pro 12 bit ultra speed intensified imaging
hsfc pro 12 bit ultra speed intensified imaging four MCP-image intensifier camera modules ultra fast shutter down to 3 ns in single mode excellent sensitivity of the system allows single photon detection
A Laser Scanner Chip Set for Accurate Perception Systems
A Laser Scanner Chip Set for Accurate Perception Systems 313 A Laser Scanner Chip Set for Accurate Perception Systems S. Kurtti, J.-P. Jansson, J. Kostamovaara, University of Oulu Abstract This paper presents
THE IMPOSSIBLE DOSE HOW CAN SOMETHING SIMPLE BE SO COMPLEX? Lars Hode
THE IMPOSSIBLE DOSE HOW CAN SOMETHING SIMPLE BE SO COMPLEX? Lars Hode Swedish Laser-Medical Society The dose is the most important parameter in laser phototherapy. At a first glance, the dose seem very
Time-Correlated Single Photon Counting
Technical Note Time-Correlated Single Photon Counting Michael Wahl PicoQuant GmbH, Rudower Chaussee 29, 12489 Berlin, Germany, [email protected] The Principle of Time-Correlated Single Photon Counting
Optical Communications
Optical Communications Telecommunication Engineering School of Engineering University of Rome La Sapienza Rome, Italy 2005-2006 Lecture #2, May 2 2006 The Optical Communication System BLOCK DIAGRAM OF
Spectral Measurement Solutions for Industry and Research
Spectral Measurement Solutions for Industry and Research Hamamatsu Photonics offers a comprehensive range of products for spectroscopic applications, covering the, Visible and Infrared regions for Industrial,
CHAPTER 6 PHOTON COUNTING
CHAPTER 6 PHOTON COUNTING 1) 2) 4) - 12) Photon counting is an effective technique used to detect very-lowlevel-light such as Raman spectroscopy, fluorescence analysis, and chemical or biological luminescence
Fig.1. The DAWN spacecraft
Introduction Optical calibration of the DAWN framing cameras G. Abraham,G. Kovacs, B. Nagy Department of Mechatronics, Optics and Engineering Informatics Budapest University of Technology and Economics
PUMPED Nd:YAG LASER. Last Revision: August 21, 2007
PUMPED Nd:YAG LASER Last Revision: August 21, 2007 QUESTION TO BE INVESTIGATED: How can an efficient atomic transition laser be constructed and characterized? INTRODUCTION: This lab exercise will allow
FRET Basics and Applications an EAMNET teaching module
FRET Basics and Applications an EAMNET teaching module Timo Zimmermann + Stefan Terjung Advanced Light Microscopy Facility European Molecular Biology Laboratory, Heidelberg http://www.embl.de/almf/ http://www.embl.de/eamnet/
Advances in scmos Camera Technology Benefit Bio Research
Advances in scmos Camera Technology Benefit Bio Research scmos camera technology is gaining in popularity - Why? In recent years, cell biology has emphasized live cell dynamics, mechanisms and electrochemical
GAMMA-RAY SPECTRA REFERENCES
GAMMA-RAY SPECTRA REFERENCES 1. K. Siegbahn, Alpha, Beta and Gamma-Ray Spectroscopy, Vol. I, particularly Chapts. 5, 8A. 2. Nucleonics Data Sheets, Nos. 1-45 (available from the Resource Centre) 3. H.E.
ULTRAFAST LASERS: Free electron lasers thrive from synergy with ultrafast laser systems
Page 1 of 6 ULTRAFAST LASERS: Free electron lasers thrive from synergy with ultrafast laser systems Free electron lasers support unique time-resolved experiments over a wide range of x-ray wavelengths,
Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014
Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014 Introduction Following our previous lab exercises, you now have the skills and understanding to control
Towards large dynamic range beam diagnostics and beam dynamics studies. Pavel Evtushenko
Towards large dynamic range beam diagnostics and beam dynamics studies Pavel Evtushenko Motivation Linacs with average current 1-2 ma and energy 1-2.5 GeV are envisioned as drivers for next generation
Lectures about XRF (X-Ray Fluorescence)
1 / 38 Lectures about XRF (X-Ray Fluorescence) Advanced Physics Laboratory Laurea Magistrale in Fisica year 2013 - Camerino 2 / 38 X-ray Fluorescence XRF is an acronym for X-Ray Fluorescence. The XRF technique
AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy
Microscopy from Carl Zeiss AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy New Dimensions in Performance AxioCam MR from Carl Zeiss Both
AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE
AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified High Speed Fiber Photodetector. This user s guide will help answer any questions you may have regarding the
Introduction to flow cytometry
Introduction to flow cytometry Flow cytometry is a popular laser-based technology. Discover more with our introduction to flow cytometry. Flow cytometry is now a widely used method for analyzing the expression
Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.
Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ., Raleigh, NC One vital step is to choose a transfer lens matched to your
Short overview of TEUFEL-project
Short overview of TEUFEL-project ELAN-meeting may 2004 Frascati (I) Contents Overview of TEUFEL project at Twente Photo cathode research Recent experience Outlook Overview FEL Drive laser Photo cathode
INFITEC - A NEW STEREOSCOPIC VISUALISATION TOOL BY WAVELENGTH MULTIPLEX IMAGING
INFITEC - A NEW STEREOSCOPIC VISUALISATION TOOL BY WAVELENGTH MULTIPLEX IMAGING Helmut Jorke, Markus Fritz INFITEC GmbH, Lise-Meitner-Straße 9, 89081 Ulm [email protected] Phone +49 731 550299 56 Fax _
5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy
5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy Resolution of optical microscope is limited by diffraction. Light going through an aperture makes diffraction
Broadband THz Generation from Photoconductive Antenna
Progress In Electromagnetics Research Symposium 2005, Hangzhou, China, August 22-26 331 Broadband THz Generation from Photoconductive Antenna Qing Chang 1, Dongxiao Yang 1,2, and Liang Wang 1 1 Zhejiang
GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3
GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3 WARNING: Store below 25ºC Store away from radiation sources Do not expose film to sunlight Handle film carefully, creasing may cause damage Do not expose to temperatures
Design and Test of Fast Laser Driver Circuits
Design and Test of Fast Laser Driver Circuits Since the invention of the laser by Theodore H Maiman 50 years ago, lasers have found widespread applications in various technological fields, such as telecommunications,
University of California at Santa Cruz Electrical Engineering Department EE-145L: Properties of Materials Laboratory
University of California at Santa Cruz Electrical Engineering Department EE-145L: Properties of Materials Laboratory Lab 8: Optical Absorption Spring 2002 Yan Zhang and Ali Shakouri, 05/22/2002 (Based
Preface Light Microscopy X-ray Diffraction Methods
Preface xi 1 Light Microscopy 1 1.1 Optical Principles 1 1.1.1 Image Formation 1 1.1.2 Resolution 3 1.1.3 Depth of Field 5 1.1.4 Aberrations 6 1.2 Instrumentation 8 1.2.1 Illumination System 9 1.2.2 Objective
T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p
Data Transmission Concepts and terminology Transmission terminology Transmission from transmitter to receiver goes over some transmission medium using electromagnetic waves Guided media. Waves are guided
It has long been a goal to achieve higher spatial resolution in optical imaging and
Nano-optical Imaging using Scattering Scanning Near-field Optical Microscopy Fehmi Yasin, Advisor: Dr. Markus Raschke, Post-doc: Dr. Gregory Andreev, Graduate Student: Benjamin Pollard Department of Physics,
E190Q Lecture 5 Autonomous Robot Navigation
E190Q Lecture 5 Autonomous Robot Navigation Instructor: Chris Clark Semester: Spring 2014 1 Figures courtesy of Siegwart & Nourbakhsh Control Structures Planning Based Control Prior Knowledge Operator
PoS(PhotoDet 2012)068
Characterization of the Hamamatsu R11265 multi-anode photomultiplier tube with single photon signals Luca CADAMURO, Marta CALVI, Andrea GIACHERO,, Matteo MAINO, Clara MATTEUZZI, Gianluigi PESSINA Dipartimento
Acoustic GHz-Microscopy: Potential, Challenges and Applications
Acoustic GHz-Microscopy: Potential, Challenges and Applications A Joint Development of PVA TePLa Analytical Systems GmbH and Fraunhofer IWM-Halle Dr. Sebastian Brand (Ph.D.) Fraunhofer CAM Fraunhofer Institute
Fluorescent dyes for use with the
Detection of Multiple Reporter Dyes in Real-time, On-line PCR Analysis with the LightCycler System Gregor Sagner, Cornelia Goldstein, and Rob van Miltenburg Roche Molecular Biochemicals, Penzberg, Germany
Lecture - 4 Diode Rectifier Circuits
Basic Electronics (Module 1 Semiconductor Diodes) Dr. Chitralekha Mahanta Department of Electronics and Communication Engineering Indian Institute of Technology, Guwahati Lecture - 4 Diode Rectifier Circuits
2 Absorbing Solar Energy
2 Absorbing Solar Energy 2.1 Air Mass and the Solar Spectrum Now that we have introduced the solar cell, it is time to introduce the source of the energy the sun. The sun has many properties that could
Infrared Viewers. Manual
Infrared Viewers Manual Contents Introduction 3 How it works 3 IR viewer in comparison with a CCD camera 4 Visualization of infrared laser beam in mid-air 4 Power Density 5 Spectral sensitivity 6 Operation
AxioCam HR The Camera that Challenges your Microscope
Microscopy from Carl Zeiss AxioCam HR The Camera that Challenges your Microscope Documentation at the edge of the visible The Camera for Maximum Success: AxioCam HR Low light fluorescence, live cell imaging,
Ti:Sapphire Lasers. Tyler Bowman. April 23, 2015
Ti:Sapphire Lasers Tyler Bowman April 23, 2015 Introduction Ti:Sapphire lasers are a solid state laser group based on using titanium-doped sapphire (Ti:Al 2O 3) plates as a gain medium. These lasers are
GAFCHROMIC DOSIMETRY MEDIA, TYPE HD-V2
GAFCHROMIC DOSIMETRY MEDIA, TYPE HD-V2 WARNING: Store below 25ºC Store away from radiation sources Do not expose film to sunlight Handle film carefully, creasing may cause damage Do not expose to temperatures
Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces
Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces WP1281 Issued: November 2015 Supersedes: 2012 Author: Dr. Russell Ellis ISO 9001 Registered Background
Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term 1998-99
Engineering Sciences 151 Electromagnetic Communication Laboratory Assignment 3 Fall Term 1998-99 WAVE PROPAGATION II: HIGH FREQUENCY SLOTTED LINE AND REFLECTOMETER MEASUREMENTS OBJECTIVES: To build greater
Lecture 14. Point Spread Function (PSF)
Lecture 14 Point Spread Function (PSF), Modulation Transfer Function (MTF), Signal-to-noise Ratio (SNR), Contrast-to-noise Ratio (CNR), and Receiver Operating Curves (ROC) Point Spread Function (PSF) Recollect
Ultrasonic Wave Propagation Review
Ultrasonic Wave Propagation Review Presented by: Sami El-Ali 1 1. Introduction Ultrasonic refers to any study or application of sound waves that are higher frequency than the human audible range. Ultrasonic
Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19
Doppler Doppler Chapter 19 A moving train with a trumpet player holding the same tone for a very long time travels from your left to your right. The tone changes relative the motion of you (receiver) and
Copyright 1999 2010 by Mark Brandt, Ph.D. 12
Introduction to Absorbance Spectroscopy A single beam spectrophotometer is comprised of a light source, a monochromator, a sample holder, and a detector. An ideal instrument has a light source that emits