How-To Set Custom Scale Format for FedEx Ship Manager



Similar documents
LP 2844 Thermal Printer

Using HyperTerminal with Agilent General Purpose Instruments

Configuring Serial Terminal Emulation Programs

Additional Setup Instructions for Modbus: RTU, ASCII, TCP, Omni & Enron

MS830 / MS833 Barcode Reader v1.0 9-December-2014

The Answer to the 14 Most Frequently Asked Modbus Questions

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

Instructions on How to Use HyperTerminal to Test Serial Ports ...

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

How to setup a serial Bluetooth adapter Master Guide

ZP 500 Plus Thermal Printer

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

DUKANE Intelligent Assembly Solutions

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

SYMETRIX SOLUTIONS: TECH TIP August 2015

SETTING UP A REMOTE MODEM CONNECTION Application Note 27

Vicon Flash Upgrade Software

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

PaymentNet Federal Card Solutions Cardholder FAQs

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

Easy Setup Guide for the Sony Network Camera

Vicon Flash Upgrade Software

How To Set Up A Smart Card Programmer With Titan (Titan) And Titan 2.3 (Tok) (Tonga) (Powerbook) (Smart Card) (Programmer) (S

BW-500 BED WEIGHER USER MANUAL

ZP 505 Thermal Printer

Parallax Serial LCD 2 rows x 16 characters Non-backlit (#27976) 2 rows x 16 characters Backlit (#27977) 4 rows x 20 characters Backlit (#27979)

CNC Transfer. Operating Manual

Windows 7 XP Mode Application Note

Practice Fusion API Client Installation Guide for Windows

Technical Information Sheet Page 1 of 8

Important Notes for WinConnect Server VS Software Installation:

Schneider OS-Loader usage via Ethernet or USB.

1 Requirements. 2 Configuration. Axis-compatible Camera Application Integration.

File Management Utility. T u t o r i a l

Modbus and ION Technology

Configuring Network Load Balancing with Cerberus FTP Server

HP Point of Sale (POS) Peripherals Configuration Guide ap5000 VFD Windows (non-opos)

account multiple solutions

L Firmware And FPGA Configuration Upgrade

LH110 Series DVR: Frequently Asked Questions

WinPFT File Transfer Utility (Catalog No ND7)

LP1000N. Software Manual PLU Management Label Editor. Date: 22-NOV Support Model. Version

Configuring the FAR2XX7 Series Radar for use with MaxSea Time Zero

RcWare SoftPLC Modbus server mapping editor User manual

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

Application & Quick-Start Guide

I. DigitalCAT Captioning Software Overview A. Welcome B. Acquiring the Captioning Add-On C. Purpose of this Guide...

POS Integration. Prepared by: Binh Nguyen

Connecting the Console Port to a PC

Parental Control Setup Guide

Allen Bradley PLC connection procedure (RSLogix 500 Version 3.1.9, RSLinx Version 2.1)

Inventory Manager. Getting started Usage and general How-To

Omron I/O Driver (Series 2) Programmable Serial Interface Card

You can search the event by POS and you can also add the Time Search condition to narrow the search range. By

For support on the Beijer HMI please contact:


How to install and use the File Sharing Outlook Plugin

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

UDG1000 Hach PCX2200 Serial Port Input Driver configuration

VM0808H HDMI Matrix Switch RS-232 Control Tool V User Manual

IP Link Device Interface Communication Sheet

TP- 051 GPS RECEIVER

File Transfers. Contents

Bend Sensor USB User Guide

Model 288B Charge Plate Graphing Software Operators Guide

NUM INFORMATION US N 111 1/9

EasyC. Programming Tips

How to share media files through Windows Media Player 11

Deposit Direct. Getting Started Guide

Cypress CY7C64225 USB-to-UART Setup Guide Version 1.3

Installing Your Multifunction to Your Network for the First Time

A6210 WiFi USB Adapter ac USB 3.0 Dual Band User Manual

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

Communications Instructions for DOOSAN, FANUC Controls

Printer Support Guide. FedEx Ship Manager Software

DIRECT INTERNET DATA. User s Guide

User Manual. Thermo Scientific Orion

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Application Note Connect to a Rockwell PLC over Netbiter Remote Access

Using the Parani SD1000U/SD1000 with Carlson SurvCE

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

56800/E SCI Hands-On Exercise

Accessing Diagnostics using a Dialup Modem

ELFRING FONTS UPC BAR CODES

Upgrade Instructions. View Manager 96 v Software Upgrade

TDP-136 TRANSCEIVER DATA PROGRAMMER

Install MS SQL Server 2012 Express Edition

SysAid Remote Discovery Tool

Knowledge Base POS/C31A Troubleshooting

How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Question How do I access the router s web-based setup page? Answer

January 9, Xerox Global Print Driver Installation Guide

Transcription:

How-To Set Custom Scale Format for FedEx Ship Manager This document describes how to custom configure FedEx Ship Manager to communicate with an Avery Weigh-Tronix scale. Ship Manager should be version 24.72 or newer and the scale must use NCI Protocol. Table of Custom Scale Configuration Settings Scale Model Communications Protocol Setup for NCI Protocol Baud Rate Data Bits Parity Stop Bits Query Response Format NCI 3825 4800 7 E 1 W xwwwwwwwttxxxxxx NCI 3835 4800 7 E 1 W xwwwwwwwttxxxx WTX 37XX 9600 8 N 1 W xwwwwwwttxxxxxx NCI 6710 9600 7 E 1 W xwwwwwwwttxxxxxx NCI 78XX 9600 7 E 1 W xwwwwwwwttxxxxxx NCI 7815.1 Rev B 9600 7 E 1 W xwwwwwwwttxxxxxxx NCI 7815.1 New 9600 7 E 1 W xwwwwwwwttxxxxxx NCI 7620 9600 7 E 1 W xwwwwwwwwttxxxxxxx LPS 150/400 9600 7 E 1 W xwwwwwwwwwttxxxxxxx Ship Manager does not as yet automatically include configuration settings for Avery Weigh- Tronix scales as part of its installation. Fortunately, it is very easy to perform a custom scale configuration in Ship Manager to support most scales provided by Avery Weigh-Tronix. The Table of Custom Scale Configuration Settings above will help you quickly select the needed settings for your scale. Later in this document, a software tool will be described that can help automatically determine the Response Format for a scale not listed in the table. The following example shows the steps required to configure Ship Manager to communicate with (and acquire weight data from) an NCI Model 6710. 4/30/2011 1

Launch FedEx Ship Manager From the main menu bar Click on Utilities Then click on Configure Scale from the dropdown list 4/30/2011 2

The Configure Scale editor will be displayed. IMPORTANT: Select Custom from the Scale Type selection list and then select the serial Port that your scale is connected to. Format string from table of settings (above) or generated from the software tool described later in this document. Next, set the Communications settings (i.e. Baud Rate, Data Bits, Parity and Stop Bits), to the values obtained from the Table of Custom Scale Configuration Settings above for your particular scale. Finally, set the Protocol - Query String to W and the Response Format string to the value specified in the table (or from the software tool described later in this document). Note that the value for Query String is typically an uppercase W. IMPORTANT: The Response Format string is always lowercase with no spaces between characters. Configuration is complete, but do not close the Configure Scale window yet. You are now ready to test the settings and operation with your scale. Make sure that your cable is securely connected to the scale and to the RS-232 serial communication port on your computer. If you have not already done so, apply power to the scale. After the scale completes counting down, click on the Test Scale button. 4/30/2011 3

Notice the status string that is displayed. The two important fields are the Weight Area and the Weight Type. The value displayed in the Weight Area should be the same as that displayed on the scale. The two-character Weight Type should match the current units-of-measure setting of the scale. IMPORTANT: In addition to the correct weight value being displayed in the Weight Area, it is very important that the correct two-character units-of-measure be displayed in the Weight Type area. If you should ever change scale calibration or modify the Response Format string you must re-test to be sure these fields are correct. The two lowercase t s (i.e. tt) represent the position of the units-of-measure in the response data from the scale. The status will be updated each time you click on the Test Scale button. When you are satisfied that the weight and type strings display correctly, you can then click on the OK button to save the settings and return to the main screen. 4/30/2011 4

NOTE: Weight will not be displayed unless the Number of Packages is set to at least 1 and the entry cursor is placed in the Weight entry box. Notice that, in this particular example, the Weight indicates 2.06 lbs even though the Weight Area for the scale test was 2.055 lb. This rounding is performed by Ship Manager. TIPS: If the scale is recalibrated from lb to kg, then the units indicated next to the weight value will automatically change to reflect the new Weight Type field it received from the scale. Weight will not be displayed if the scale weight is at zero or in-motion. Changing weight values on the scale will not be reflected in the Weight box unless the Weight box has focus (i.e. it has the entry cursor and is highlighted). If scale weight goes negative for five (5) seconds, an error message will be displayed indicating The scale is not present. Even after the condition is corrected and a positive (non-zero) weight is applied to the scale, weight will still not be displayed until focus is removed from and returned to the Weight entry box. This can be done simply by clicking on the Number of Packages box (without changing the value), and then clicking on the Weight entry box again. 4/30/2011 5

A Tool to Generate a Scale Response Format This section describes how you can use a freely available software utility tool from Avery Weigh-Tronix to automatically generate the Response Format string appropriate for your scale. You may need to do this if your Avery Weigh-Tronix scale is not currently listed in the Table of Custom Scale Configuration Settings above or you suspect that a change to the format is needed due to recalibration to a different capacity or units-of-measure. In any case, the utility software tool will run stand-alone (i.e. outside of Ship Manager). It will communicate with the scale and generate the format string to be entered in the custom scale configuration editor in FedEx Ship Manager as described earlier in this document. NOTE: To run the utility software you will still need to know the scales communication settings currently set in the scale (i.e. Baud Rate, Data Bits, Parity, and Stop Bits). Also, the scale must be configured to use the NCI Protocol. You can download the awtxscaletest utility software here from the Salter Brecknell website. After downloading and installing the software, launch the application and complete the following steps: 4/30/2011 6

From the Test Mode dropdown list, click on FedEx Ship Manager. Select the Serial Port and Serial Port Settings to match those set in the scale. The pre-defined W query string is entered automatically Next, click the Open Port button. 4/30/2011 7

You are now ready to read the scale and generate the format string. Make sure that your cable is securely connected to the scale and to the RS-232 serial communication port on your computer. If you have not already done so, apply power to the scale and let it complete the countdown sequence. Make sure that the scale display reading is stable (i.e. no motion), not under zero, and not overcapacity. Then, click the Send button. 4/30/2011 8

The Response Format string is generated and displayed. You can place different loads on the scale and click Send again. The format string should not change with load changes. If it does, then the scales protocol may not be suitable for use with Ship Manager. Contact Salter Brecknell service for assistance. You can change the RxD View from FEDEX to ASCII or HEX in order to see the scale data displayed in other more readable text to assist you in testing and debugging the response format string. sales@salterbrecknell.com service@salterbrecknell.com 1-800-637-0529 1-800-242-2807 4/30/2011 9