56800/E SCI Hands-On Exercise

Size: px
Start display at page:

Download "56800/E SCI Hands-On Exercise"

Transcription

1 56800/E SCI Hands-On Exercise 56800/E Slide 1 Training Presenter Logo Here Slide 1

2 Task Description Develop a monitor application that uses SCI in messages between PC and DSC56F801x EVB. HyperTerminal (Console) for CAN Data Display via RS232, Bits/sec : 9600 No parity : none Stop bit : 1 Hardware : None Serial Port (SCI) RS232 56F801x EVB 56F801x JTAG-DSP AXM-0337 Slide 2

3 Approach Use Processor Expert Beans to implement Target System application AsynchroSerial Download and Execute on 56F801x Demo Board Slide 3

4 Click File pull down menu Slide 4

5 Select PE stationary Type SCI Exercise inside the dial box Slide 5

6 Select MC56F8013VFAE project stationery Slide 6

7 PE template is shown on. Slide 7

8 Kick AsynchroSerial Bean under Communication PE menu Then, kick Baud rate dial box under the properties of Bean Inspector AS1:AsynchroSerial Slide 8

9 Type 9600 baud rate inside the dial box Slide 9

10 Select Generate Code SCI Exercise.mcp under PE pull down menu to generate the code Slide 10

11 Slide 11

12 Open up the SCI_Exercise.c:main file to edit user code. Slide 12

13 Select PE Bean SendChar for sending out characters Slide 13

14 Put PE Bean SendChar to SCI_Exercise.c:main by Drag-n-Drop Methods. Slide 14

15 Made more characters to send out by Copy-n-Paste methods. Slide 15

16 We need to wait for the 1 st character send out completely if we want to send out 2 nd character in SCI communication. kick Methods page of Bean Inspector AS1:AsynchroSerial Slide 16

17 Enable GetRxIdle PE Bean by kicking this dial box Slide 17

18 Enable GetTxComplete PE Bean by kicking this dial box Slide 18

19 Scroll up the screen to reach GetTxComplete PE Bean by kick the scroll bar Slide 19

20 Put PE Bean GetTxComplete to SCI_Exercise.c:main by Drag-n-Drop Methods. Slide 20

21 Modify it as while statement. Slide 21

22 Make every while statement for every character sending out. Slide 22

23 Slide 23

24 Kick Yes to update the code. Slide 24

25 Slide 25

26 Kick green arrow to download the code to 56F801xEVB. Slide 26

27 Slide 27

28 Slide 28

29 Slide 29

30 Kick green arrow to run the code inside 56F801xEVB. Slide 30

31 Invoke HyperTerminal for getting the characters from 56F801xEVB. Slide 31

32 Type the name you want Slide 32

33 Select your PC COM port for communication Slide 33

34 Select 9600 baud rate, 8 data bit, no parity,1 stop bit, none flow control Then, kick OK Slide 34

35 Hello is shown on the HyperTerminal screen Slide 35

36 Summary 56800/E Slide 36 Training Presenter Logo Here Slide 36

37 Summary Understand the hardware and software support available for the 56800E Hybrid Controller product line. Demonstrated the ease of developing applications using CodeWarrior development tools with Processor Expert technology. Slide 37

38 Thank You!!! Slide 38

L1255-4149 Firmware And FPGA Configuration Upgrade

L1255-4149 Firmware And FPGA Configuration Upgrade Technical Note TN133 Issue:2 L1255-4149 Firmware And FPGA Configuration Upgrade IMPORTANT NOTE: When using USB to Serial converters and upgrading the Firmware there is a danger of early L1255s becoming

More information

Configuring Serial Terminal Emulation Programs

Configuring Serial Terminal Emulation Programs Configuring Serial Terminal Emulation Programs Table of Contents Configuring Serial Terminal Emulation Programs: An Introduction... 3 HyperTerminal... 3 Configuring HyperTerminal... 3 Tera Term Pro...

More information

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter ABB solar inverters Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter Introduction This document details the procedure for the installation on a user s computer

More information

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification: PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,

More information

User Manual. Thermo Scientific Orion

User Manual. Thermo Scientific Orion User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation

More information

Using HyperTerminal with Agilent General Purpose Instruments

Using HyperTerminal with Agilent General Purpose Instruments Using HyperTerminal with Agilent General Purpose Instruments Windows HyperTerminal can be used to program most General Purpose Instruments (not the 531xx series counters) using the RS-232 Serial Bus. Instrument

More information

Keep it Simple Timing

Keep it Simple Timing Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring

More information

IP SERIAL DEVICE SERVER

IP SERIAL DEVICE SERVER IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6

More information

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.

More information

TP- 051 GPS RECEIVER

TP- 051 GPS RECEIVER TP- 051 GPS RECEIVER CONTENTS 1. Overview 3 2. Features 3 3. The advantages of TP-051 GPS Receiver 4 4. The appearance and structures 4 5. Applications 5 6. Installation steps for the TP-051 GPS Receiver

More information

PM1122 INT DIGITAL INTERFACE REMOTE

PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings

More information

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication

More information

SETTING UP A REMOTE MODEM CONNECTION Application Note 27

SETTING UP A REMOTE MODEM CONNECTION Application Note 27 SETTING UP A REMOTE MODEM CONNECTION Application Note 27 with WeatherLink for Windows Serial Version Only INTRODUCTION This document provides guidelines on how to set up a remote modem connection. This

More information

Guide to Installing BBL Crystal MIND on Windows 7

Guide to Installing BBL Crystal MIND on Windows 7 Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP

More information

Configuring the Switch with the CLI Setup Program

Configuring the Switch with the CLI Setup Program APPENDIXC Configuring the Switch with the CLI Setup Program This appendix provides a command-line interface (CLI) setup procedure for a standalone switch. To set up the switch by using Express Setup, see

More information

Windows 7 XP Mode Application Note

Windows 7 XP Mode Application Note 17741 Mitchell North, Irvine, CA 92614 USA Tel: 949-833-3355 Fax: 949-833-0322 http://www.genovation.com support@genovation.com Windows 7 XP Mode Application Note Using a MiniTerm with Legacy Software

More information

Accessing Diagnostics using a Dialup Modem

Accessing Diagnostics using a Dialup Modem Purpose This application note is meant to guide a user through the setup and use of a dial-up modem to retrieve diagnostics data from a remote master. Equipment Used This application note was written specifically

More information

Connecting the DG-102S VoIP Gateway to your network

Connecting the DG-102S VoIP Gateway to your network Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information

More information

DUKANE Intelligent Assembly Solutions

DUKANE Intelligent Assembly Solutions PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0 MAX T1/E1 TM VoIP Gateway Quick Start Guide Version 1.0 Contents INTRODUCTION 1 Hardware Needed Software Needed 1 1 NET2PHONE MAX SET UP Hardware Set Up Software Set Up Set Up Internet Protocol (IP) Address

More information

Cypress CY7C64225 USB-to-UART Setup Guide Version 1.3

Cypress CY7C64225 USB-to-UART Setup Guide Version 1.3 Cypress CY7C64225 USB-to-UART Setup Guide Version 1.3 Overview The Cypress CY7C64225 is a fully integrated USB-to-UART Bridge that provides a simple way of updating RS-232 based devices to USB with a minimal

More information

Connecting your Omega/BetaPAT PLUS to a PC via a USB

Connecting your Omega/BetaPAT PLUS to a PC via a USB Connecting your Omega/BetaPAT PLUS to a PC via a USB Install software Windows XP and below Insert the disc into your computers disc drive and run through the setup wizard. Windows Vista & 7 1. Insert the

More information

Maintaining the Content Server

Maintaining the Content Server CHAPTER 7 This chapter includes the following Content Server maintenance procedures: Backing Up the Content Server, page 7-1 Restoring Files, page 7-3 Upgrading the Content Server, page 7-5 Shutting Down

More information

Liebert IntelliSlot Web Cards

Liebert IntelliSlot Web Cards Monitoring For Business-Critical Continuity Liebert IntelliSlot Web Cards Firmware Upgrade Manual Liebert IntelliSlot Web Card, Liebert IntelliSlot Web Card-LB, Liebert IntelliSlot Web Card-LBDS, Liebert

More information

Driver Installation and Hyperterminal Operation of iload Digital USB Sensors

Driver Installation and Hyperterminal Operation of iload Digital USB Sensors Driver Installation and Hyperterminal Operation of iload Digital USB Sensors Driver Installation Insert the iload Digital USB Driver CD OR the LoadVUE or LoadVUE Lite CD into your computer s drive. If

More information

File Management Utility. T u t o r i a l

File Management Utility. T u t o r i a l File Management Utility T u t o r i a l Contents System Requirements... 2 Preparing Files for Transfer to GlobalMark... 2 Application Launch... 2 Printer Setup... 2 Communication Status... 4 Communication

More information

ADDENDUM - Bluetooth interface Option Instructions for using Extech Printer with a Bluetooth device

ADDENDUM - Bluetooth interface Option Instructions for using Extech Printer with a Bluetooth device Introduction ADDENDUM - Bluetooth interface Option Instructions for using Extech Printer with a Bluetooth device Extech 3500T and 2500T thermal printers support full range of communication interfaces,

More information

Voice Over Internet Protocol (VoIP) Configuration

Voice Over Internet Protocol (VoIP) Configuration (VoIP) Configuration ENGINEERING REPORT No: 02-003 Introduction This report describes interfacing the IPCS VoIP Gateway Model EGW-902 to an ESTeem Model 192E Wireless Ethernet radio modem in a demonstration

More information

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT. INLINE 5 Software INSTALL BULLETIN Page 2: Installing INLINE 5 Page 6: Removing INLINE 5 NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT. IMPROPER INSTALLATION OR USE CAN

More information

Table of Contents Install a Printer Driver... 2 Print a Test Label... 9 Uninstall a Printer and Driver... 10

Table of Contents Install a Printer Driver... 2 Print a Test Label... 9 Uninstall a Printer and Driver... 10 Table of Contents Install a Printer Driver... 2 Print a Test Label... 9 Uninstall a Printer and Driver... 10 Copyright 2016, United Parcel Service of America, Inc. All rights reserved. 1 Install a Printer

More information

PC Program User s Guide (01.01.05) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

PC Program User s Guide (01.01.05) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming Work Off-Line Set up a new database or modify a previously saved database (without being connected to the telephone system). This helps minimize on-site programming time. Work On-Line (connected directly

More information

MAGELLAN CONNECTING TO CASH REGISTER EXPRESS

MAGELLAN CONNECTING TO CASH REGISTER EXPRESS MAGELLAN CONNECTING TO CASH REGISTER EXPRESS Programming codes are for the following products: Magellan 8100 Magellan 8200 Magellan 8300 Magellan 8400 Magellan 8500 Magellan 8500XT Magellan 8500XTS Magellan

More information

USB PC Adapter V4 Configuration

USB PC Adapter V4 Configuration Programming PC adapter V4 USB PC Adapter V4 Configuration PC adapter with USB cable Flat Ribbon Cable Power Supply Unit Device Driver General The USB PC adapter V4 is used for communication between a PC

More information

When upgrading your TAPIT software make sure that all call accounting data has been exported before you begin the installation process.

When upgrading your TAPIT software make sure that all call accounting data has been exported before you begin the installation process. When upgrading your TAPIT software make sure that all call accounting data has been exported before you begin the installation process. Registration Settings: SERIAL NUMBER: COMPUTER ID: REGISTRATION NUMBER:

More information

TAS-2000 Series. MSW-003 Software. User Guide. LT-880 Rev. 1 September 2004

TAS-2000 Series. MSW-003 Software. User Guide. LT-880 Rev. 1 September 2004 Advanced Life Safety Solutions TAS-2000 Series MSW-003 Software 3 4 5 7 8 9 0 User Guide LT-880 Rev. 1 September 2004 Contents TAS-2000 MSW-003 Software Manual Installing the Software... 1 Connecting

More information

Acton Research Technical Support SpectraPro Diagnostic Procedure

Acton Research Technical Support SpectraPro Diagnostic Procedure Acton Research Technical Support SpectraPro Diagnostic Procedure Table of Contents Introduction to the Acton Research Technical Support SpectraPro Diagnostic Procedure...1 Checking the USB Drivers...2

More information

Palomar College Dial-up Remote Access

Palomar College Dial-up Remote Access Palomar College Dial-up Remote Access Instructions for Windows 95/98 and Windows 2000 Following are instructions to implement dialup access to the Palomar College network, email and Internet. The minimum

More information

Attendance Messenger Inbox, Email and Voice

Attendance Messenger Inbox, Email and Voice First, select the current school year and calendar. 1. Go to 2. Select a User Group or Template, if you wish. 3. Enter the

More information

Knowledge Base POS/C31A Troubleshooting

Knowledge Base POS/C31A Troubleshooting [Concept] Serial Port Include RS-232, RS-422, RS-485 and USB Currently NUUO only supports RS-232 Also named as COM port by Microsoft Why Null Modem? The RS-232 standard is asymmetrical as to the definitions

More information

POS Integration. Prepared by: Binh Nguyen

POS Integration. Prepared by: Binh Nguyen POS Integration Prepared by: Binh Nguyen Point of Sale (POS) Compatibility To know whether it is possible to integrate your POS system with our DVR, please check whether the type of printer the POS system

More information

Firmware upgrade instructions for the Web/SNMP and Network

Firmware upgrade instructions for the Web/SNMP and Network Page 1 of 6 Answer ID 768 Firmware upgrade instructions for the Web/SNMP and Network Management Cards Question How do I upgrade the firmware on an APC Web/SNMP Management Card or Network Management Card?

More information

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM COMMUNICATIONS WITH AN OCTOPUS. Article # 072297-1 Last reviewed: 03/25/98 Keywords: Serial Port, Modem, Polling, AquaWeb, Node Not Responding

More information

PP8X Printer Driver Installation Instruction

PP8X Printer Driver Installation Instruction PP8X Printer Driver Installation Instruction Pinnacle Technology Corp. CONTENTS 1 BT Device Installation... 1 2 Printer Driver Installation... 6 3 How to Know the Connecting Port... 10 4 How to Configure

More information

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

E-Mon Communication Gateway Utility Instructions for BACnet/mstp E-Mon Communication Gateway Utility Instructions for BACnet/mstp The E-Mon Communication Gateway utility will allow you to configure the Device Instance (Node ID) and other parameters needed for your BACnet/mstp

More information

FN:PCMCSET-M1.DOC. PCMCSET SOFTWARE for ATS Master Clocks System Clocks and Displays

FN:PCMCSET-M1.DOC. PCMCSET SOFTWARE for ATS Master Clocks System Clocks and Displays FN:PCMCSET-M1.DOC PCMCSET SOFTWARE for ATS Master Clocks System Clocks and Displays ATS FREE SOFTWARE AGREEMENT Applied Technical Systems (ATS) grants you the right to use this software according to the

More information

VM0808H HDMI Matrix Switch RS-232 Control Tool V1.0.064 User Manual

VM0808H HDMI Matrix Switch RS-232 Control Tool V1.0.064 User Manual VM0808H HDMI Matrix Switch RS-232 Control Tool V1.0.064 User Manual www.aten.com FCC Information This is an FCC Class A product. In a domestic environment this product may cause radio interference in which

More information

Title: ZOLL USB Direct Connect Cable Installation Instructions

Title: ZOLL USB Direct Connect Cable Installation Instructions ZOLL USB Direct Connect Cable Installation Instructions Document Status: Released Document #: 48x126-ZOLL-003 Page 1 of 7 Revision History DATE REV REASON January 9, 2008 A Initial Release August 12, 2008

More information

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly

More information

Current Cost Data Cable User Guide. Installing and configuring the data cable

Current Cost Data Cable User Guide. Installing and configuring the data cable Current Cost Data Cable User Guide Installing and configuring the data cable Contents About the Data Cable... 3 Data Cable Installation Steps... 3 Post Installation Checks... 3 So the driver is installed,

More information

Installing PowerLink on Windows 7 64-bit

Installing PowerLink on Windows 7 64-bit Instruction Manual Version 1.0, Code No. 20 751 806 1 Introduction... 3 2 Installing Virtual PC... 3 3 Configuring Windows XP Mode... 5 4 Installing Powerlink to Virtual XP... 8 5 Run PowerLink software

More information

Vicon Flash Upgrade Software

Vicon Flash Upgrade Software NOTES NO. REV. SEC. INSTRUCTION MANUAL Refer to XX134-11-00 1108 3 XX134 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT through a PC using the Flash Upgrade software.

More information

How to setup a serial Bluetooth adapter Master Guide

How to setup a serial Bluetooth adapter Master Guide How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil

More information

Windows XP.. ELITE Firmware Update procedures.. v1.41

Windows XP.. ELITE Firmware Update procedures.. v1.41 Windows XP.. ELITE Firmware Update procedures.. v1.41 Download and Extract the ELITE update. Note.. Please ensure you are logged in to Windows as an Administrator before carrying out the instructions in

More information

Application Note CTAN #374

Application Note CTAN #374 Application Note CTAN #374 The Application Note is specific to the CT software packages MentorSoft, UniSoft and SeSoft Windows 7 64-bit and the Older CT Software Scope Windows 7 64-bit Professional 64-bit

More information

Atlas 6.0 Installation Guide

Atlas 6.0 Installation Guide Atlas 6.0 Installation Guide Table of Contents 1 Introduction... 1 1.1 Outline... 1 2 Software Prerequisites for Atlas 6.0... 2 2.1 Atlas Client... 2 2.2 Atlas Server... 2 2.3 For Microsoft Dynamics AX...

More information

Installing Global Logger USB Drivers

Installing Global Logger USB Drivers Installing Global Logger USB Drivers For 32-bit Windows 8, skip to the section labeled, Continue with Driver Installation. For 64-bit Windows 8, start the process here. At the time of this writing, the

More information

Connecting a Metrologic MS9535 to a USB BT Adapter (Client Mode)

Connecting a Metrologic MS9535 to a USB BT Adapter (Client Mode) Connecting a Metrologic MS9535 to a USB BT Adapter (Client Mode) I. Scope This document will provide a brief description of how to connect the Metrologic MS9535-5 scanner to a USB Bluetooth Adapter in

More information

HP Point of Sale (POS) Peripherals Configuration Guide ap5000 VFD Windows (non-opos)

HP Point of Sale (POS) Peripherals Configuration Guide ap5000 VFD Windows (non-opos) HP Point of Sale (POS) Peripherals Configuration Guide ap5000 VFD Windows (non-opos) Document Version 3.23 November 2010 1 Copyright 2007-2010 Hewlett-Packard Development Company, L.P. The information

More information

Installing ABACUS ELECTRICS USB Optical Probes under Windows 7

Installing ABACUS ELECTRICS USB Optical Probes under Windows 7 Installing ABACUS ELECTRICS USB Optical Probes under Windows 7 AN17a This note assumes that you are installing the drivers on to a clean system, i.e. one on which ABACUS ELECTRICS Optical Probe drivers

More information

Connecting and Setting Up Your Laptop Computer

Connecting and Setting Up Your Laptop Computer CHAPTER 3 Connecting and Setting Up Your Laptop Computer This chapter explains how to connect your laptop to the Cisco Unified MeetingPlace system and how to set up your laptop so that you can use HyperTerminal.

More information

PTPhoneManager II. User guide

PTPhoneManager II. User guide COMMUNICATION AT ITS BEST PTPhoneManager II User guide Communications A member of PEIKER group DOCUMENT PEI TEL Communications GmbH - PTPhoneManager II - 2 - T ABLE OF CONTENTS Table of contents Table

More information

Signature Center Getting Started Guide

Signature Center Getting Started Guide Signature Center Getting Started Guide 1113710 PRODUCED IN IRELAND Copyright 2010 McKesson Corporation and/or one of its subsidiaries. All Rights Reserved. This documentation is an unpublished work of

More information

WinPFT File Transfer Utility (Catalog No. 2711-ND7)

WinPFT File Transfer Utility (Catalog No. 2711-ND7) Technical Data WinPFT File Transfer Utility (Catalog No. 2711-ND7) Overview WINPFT is a stand-alone Windows utility which lets you transfer applications developed for standard PanelView terminals or Dataliner

More information

Vicon Flash Upgrade Software

Vicon Flash Upgrade Software INSTRUCTION MANUAL Notes Refer to XX134 NO. XX134-13-01 REV. 1212 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT and Surveyor -Mini Camera Domes through a PC using

More information

64-Bit Compatibility with Micromeritics Applications

64-Bit Compatibility with Micromeritics Applications Tech Tip 7 64-Bit Compatibility with Micromeritics Applications Micromeritics products are designed to operate in most Microsoft Windows environments. However, more current versions of Microsoft Windows,

More information

Software User Guide UG-461

Software User Guide UG-461 Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment

More information

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012 Quick Note 32 Using Digi RealPort with a Digi TransPort Router UK Support September 2012 1 Contents 1 Introduction... 3 1.1 Outline... 3 1.2 Assumptions... 3 1.3 Version... 3 2 Configuration & scenario...

More information

WindO/I-NV2 Utility Pass-Through Tool

WindO/I-NV2 Utility Pass-Through Tool B-1159(3) WindO/I-NV2 Utility Pass-Through Tool Instruction Manual Introduction This instruction manual explains the operation and handling of the WindO/I-NV2 Utility Pass-Through Tool. Before using the

More information

SatTerm-G SOFTWARE MANUAL FOR A3LA-IG

SatTerm-G SOFTWARE MANUAL FOR A3LA-IG TN2004-70-V3.2 SatTerm-G SOFTWARE MANUAL FOR A3LA-IG Version 3.2 December 6, 2004 Copyright 2004 by NAL Research Corporation The specifications in this document are subject to change at NAL Research s

More information

Centurion C4 Transfer Guide using C4 File Transfer Utility

Centurion C4 Transfer Guide using C4 File Transfer Utility Centurion C4 Transfer Guide using C4 File Transfer Utility 1010536 02 23 11 Section 50 1.0 Background: 1.1 A valid configuration is required for the Centurion system. Configuration files are downloaded

More information

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline Application Note Last reviewed: 03/17/2008 AN-KEP-003.doc Page 1 of 23 Introduction... 1 Recommended s and ports to use... 1 Cable Wiring... 2 MDM-TEL Configuration ( Wizard)... 3 Direct Logic Communications

More information

3.1 Connecting to a Router and Basic Configuration

3.1 Connecting to a Router and Basic Configuration 3.1 Connecting to a Router and Basic Configuration Objective This lab will focus on the ability to connect a PC to a router in order to establish a console session and observe the user interface. A console

More information

INF-USB2 and SI-USB Quick Start Guide

INF-USB2 and SI-USB Quick Start Guide INF-USB2 and SI-USB Quick Start Guide Please follow these instructions carefully. DO NOT connect the INF-USB2 or SI-USB module to your computer before running the setup program. After running Setup and

More information

Bill Redirect Software How To Schedule Tasks in Bill Redirect

Bill Redirect Software How To Schedule Tasks in Bill Redirect Bill Redirect Software How To Schedule Tasks in Bill Redirect Supported Operating Systems: Windows 98,Me,2000,3000,XP,NT4, Vista. This tutorial shows how you can schedule a command/action in Bill Redirect

More information

Getting Started with the Xilinx Zynq- 7000 All Programmable SoC Mini-ITX Development Kit

Getting Started with the Xilinx Zynq- 7000 All Programmable SoC Mini-ITX Development Kit Getting Started with the Xilinx Zynq- 7000 All Programmable SoC Mini-ITX Development Kit Table of Contents ABOUT THIS GUIDE... 3 ADDITIONAL DOCUMENTATION... 3 ADDITIONAL SUPPORT RESOURCES... 3 INTRODUCTION...

More information

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD

More information

Using and Installing: HCS12C32 Board, HCS12C128 Board, USB-to-Serial port driver, and HyperTerminal

Using and Installing: HCS12C32 Board, HCS12C128 Board, USB-to-Serial port driver, and HyperTerminal Using and Installing: HCS12C32 Board, HCS12C128 Board, USB-to-Serial port driver, and HyperTerminal CMPEN 472, Spring 2013, Kyusun Choi Download from the PSU Angel cmpen472 page, the USB-to-Serial port

More information

Testo FlashUpdate. Instument Software Update and Download Instructions. 1... How to Download Instrument Software and Updates from the Internet

Testo FlashUpdate. Instument Software Update and Download Instructions. 1... How to Download Instrument Software and Updates from the Internet Testo FlashUpdate Instument Software Update Contents 1.... How to Download Instrument Software and Updates from the Internet 2. How to use the Flash Program 2.1.. Instrument-Preparation before Flashing

More information

Protection Service for Business

Protection Service for Business Protection Service for Business Getting Started Guide for Mac Computers System requirements System requirements Supported platforms For all supported OS X versions. Workstation (Mac) Processor: Memory:

More information

How-To Set Custom Scale Format for FedEx Ship Manager

How-To Set Custom Scale Format for FedEx Ship Manager How-To Set Custom Scale Format for FedEx Ship Manager This document describes how to custom configure FedEx Ship Manager to communicate with an Avery Weigh-Tronix scale. Ship Manager should be version

More information

Connecting the Console Port to a PC

Connecting the Console Port to a PC This document covers tasks associated with connecting a console port to a PC, and includes the following topics: Console (rollover) Cable and Adapters Making the physical connection Connecting using HyperTerminal

More information

CE 4.2 to Windows 7 - Synchronism Problem

CE 4.2 to Windows 7 - Synchronism Problem Product: Mobile Products with Windows CE 4.2 Distribution Date: 10/04/2012 CE 4.2 to Windows 7 - Synchronism Problem This document covers how to get an older device with Windows CE 4.2 or early 5.0 to

More information

Networking Alpha signs on a TCP/IP network

Networking Alpha signs on a TCP/IP network Networking Alpha signs on a TCP/IP network Contents Introduction................. 2 Why use serial servers?........... 2 Types of serial servers available..... 3 Valid Adaptive signs for an Alpha Ethernet

More information

1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking POS function Marchen POS-DVR surveillance system is a professional surveillance integrated with POS system. By bringing video and POS transaction data together, the POS-DVR surveillance system provides

More information

Using the HCS12 Serial Monitor on Wytec Dragon-12 boards. Using Motorola s HCS12 Serial Monitor on Wytec s Dragon-12 boards

Using the HCS12 Serial Monitor on Wytec Dragon-12 boards. Using Motorola s HCS12 Serial Monitor on Wytec s Dragon-12 boards Using Motorola s HCS12 Serial Monitor on Wytec s Dragon-12 boards Wytec s Dragon-12 development boards are pre-installed with DBug-12, a small monitor program which allows a user to interact with the board

More information

Global Monitoring + Support

Global Monitoring + Support Use HyperTerminal to access your Global Monitoring Units View and edit configuration settings View live data Download recorded data for use in Excel and other applications HyperTerminal is one of many

More information

FRM301 SNMP Upgrade Procedure

FRM301 SNMP Upgrade Procedure The information within this document is intended for experienced service personnel with knowledge of TCP/IP networking, PC networking configuration, serial terminal configuration and operation. Failure

More information

026-1608 Rev 0 6-13-00. NetCom Card Installation and Programming Guide

026-1608 Rev 0 6-13-00. NetCom Card Installation and Programming Guide 026-1608 Rev 0 6-13-00 NetCom Card Installation and Programming Guide 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS RESERVED. The information contained

More information

BMV-602 Data Link Manual

BMV-602 Data Link Manual BMV-602 Data Link Manual 1 Contents of the kit 1 x BMV-602 data link cable. 1 x Installation CD 2 System Requirements 2.1 Hardware requirements A BMV-602 with software version 2.03 or higher. A spare RS-232

More information

Remote Access Server - Dial-Out User s Guide

Remote Access Server - Dial-Out User s Guide Remote Access Server - Dial-Out User s Guide 95-2345-05 Copyrights IBM is the registered trademark of International Business Machines Corporation. Microsoft, MS-DOS and Windows are registered trademarks

More information

Instructions for Installing and Using the FOCUS DL-15 Data Transfer Software

Instructions for Installing and Using the FOCUS DL-15 Data Transfer Software 27 March 2015 Instructions for Installing and Using the FOCUS DL-15 Data Transfer Software Introduction This guide will walk you through the process of transferring data from the FOCUS DL-15 to the computer

More information

NUM INFORMATION US N 111 1/9

NUM INFORMATION US N 111 1/9 US N 111 1/9 Procedure: 10xx Series CNC Backup/Restore Procedures using NUMCOM Scope: The NUM 10xx Series CNC system has essential application specific files stored in various locations within the system.

More information

How to configure Linksys SPA 941 942 for VOIP Connections

How to configure Linksys SPA 941 942 for VOIP Connections How to configure Linksys SPA 941 942 for VOIP Connections Congratulations. Welcome to VOIP Connections family. 1.) Connect the phone properly. Make sure the phone is connected securely to your router or

More information

Important Notes for WinConnect Server ES Software Installation:

Important Notes for WinConnect Server ES Software Installation: Important Notes for WinConnect Server ES Software Installation: 1. Only Windows 8/8.1 Enterprise, Windows 8/8.1 Professional (32-bit & 64-bit) or Windows Server 2012 (64-bit) or Windows Server 2012 Foundation

More information

Instruction manual. testo easyheat Configuration and Analysis software

Instruction manual. testo easyheat Configuration and Analysis software Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of

More information

Windows 95 Revision B Installation Instructions

Windows 95 Revision B Installation Instructions Windows 95 Revision B Installation Instructions Follow the instructions in this document if you are installing Live200 1.5 on a PC that runs Windows 95 revision B (OSR2). The Windows 95 version number

More information

Intuit Merchant Service for QuickBooks: Reference and Start-up Guide

Intuit Merchant Service for QuickBooks: Reference and Start-up Guide Intuit Merchant Service for QuickBooks: Reference and Start-up Guide Accepting credit cards through QuickBooks has never been easier. The screens below illustrate just how easy it is to process credit

More information

DRIVERS INSTALLATION GUIDE

DRIVERS INSTALLATION GUIDE 1M23Z00902 USB INTERFACE DRIVERS INSTALLATION GUIDE * These CIU-2 drivers are for windowsvista/xp/2000 use, and is not compatible with other OS. Downloaded ZIP extraction (decompression)...p2 Extraction

More information

Instructions on How to Use HyperTerminal to Test Serial Ports ...

Instructions on How to Use HyperTerminal to Test Serial Ports ... Print Date: 04.03.2010 Testing Serial Cards Instructions on How to Use HyperTerminal to Test Serial Ports... Brain Boxes Limited, Unit 3C, Wavertree Boulevard South, Wavertree Technology Park, Liverpool,

More information