Using Computational Fluid Dynamics (CFD) for improving cooling system efficiency for Data centers



Similar documents
Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

The CEETHERM Data Center Laboratory

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Effect of Rack Server Population on Temperatures in Data Centers

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

Application of CFD modelling to the Design of Modern Data Centres

Computational Fluid Dynamic Investigation of Liquid Rack Cooling in Data Centres

FAC 2.1: Data Center Cooling Simulation. Jacob Harris, Application Engineer Yue Ma, Senior Product Manager

Energy Efficient Data Center Design. Can Ozcan Ozen Engineering Emre Türköz Ozen Engineering

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

The New Data Center Cooling Paradigm The Tiered Approach

How To Model With Cfd Using Phoenics

Using CFD for optimal thermal management and cooling design in data centers

Airflow Simulation Solves Data Centre Cooling Problem

Data Center Cooling & Air Flow Management. Arnold Murphy, CDCEP, CDCAP March 3, 2015

Specialty Environment Design Mission Critical Facilities

CFD-Based Operational Thermal Efficiency Improvement of a Production Data Center

Benefits of. Air Flow Management. Data Center

Thermal Mass Availability for Cooling Data Centers during Power Shutdown

Dealing with Thermal Issues in Data Center Universal Aisle Containment

How To Improve Energy Efficiency Through Raising Inlet Temperatures

- White Paper - Data Centre Cooling. Best Practice

CFD ANALYSIS CHALLENGES IN BUILDING SIMULATION FOR SIMBUILD2004 CONFERENCE. Ferdinand Schmid and Galen Burrell Architectural Energy Corporation

TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF FORCED CONVECTION FLOW AND HEAT TRANSFER IN A LAMINAR CHANNEL FLOW

Great Lakes Data Room Case Study

AIR STREAMS IN BUILDING FOR BROILERS

AIR DISTRIBUTION FOR COMFORT AND IAQ

Sealing Gaps Under IT Racks: CFD Analysis Reveals Significant Savings Potential

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

Managing Cooling Capacity & Redundancy In Data Centers Today

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Data Center Components Overview

How to Build a Data Centre Cooling Budget. Ian Cathcart

Introducing Computational Fluid Dynamics Virtual Facility 6SigmaDC

Development of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

CFD Application on Food Industry; Energy Saving on the Bread Oven

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Using CFD for Data Center Design and Analysis

Driving Data Center Efficiency Through the Adoption of Best Practices

Analysis and Performance Prediction of Data Centre with Different Configurations using CFD

APC APPLICATION NOTE #92

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

BRUNS-PAK Presents MARK S. EVANKO, Principal

2013 Code_Saturne User Group Meeting. EDF R&D Chatou, France. 9 th April 2013

Role of the PI System in Georgia Tech Data Center Laboratory

Data Center Power Consumption

CCTech TM. ICEM-CFD & FLUENT Software Training. Course Brochure. Simulation is The Future

Reducing the Annual Cost of a Telecommunications Data Center

How To Run A Data Center Efficiently

Prediction Is Better Than Cure CFD Simulation For Data Center Operation.

Thermal Management of Datacenter

DataCenter 2020: first results for energy-optimization at existing data centers

Server Room Thermal Assessment

Improving Data Center Energy Efficiency Through Environmental Optimization

Flow in data racks. 1 Aim/Motivation. 3 Data rack modification. 2 Current state. EPJ Web of Conferences 67, (2014)

O.F.Wind Wind Site Assessment Simulation in complex terrain based on OpenFOAM. Darmstadt,

Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER

Elements of Energy Efficiency in Data Centre Cooling Architecture

The Influence of Aerodynamics on the Design of High-Performance Road Vehicles

Thermal Monitoring Best Practices Benefits gained through proper deployment and utilizing sensors that work with evolving monitoring systems

Statement Of Work Professional Services

NUCLEAR ENERGY RESEARCH INITIATIVE

COMPARATIVE ANALYSIS OF WIDELY USED AIR CONTAINMENT SYSTEMS IN COMMERCIAL DATA CENTERS FOR MAXIMUM COOLING PERFORMANCE KASTURI RANGAN RAJAGOPALAN

SECTION EG. Engineering Guide Air Distribution. Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution.

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

THERMAL STRATIFICATION IN A HOT WATER TANK ESTABLISHED BY HEAT LOSS FROM THE TANK

Ravi Kumar Singh*, K. B. Sahu**, Thakur Debasis Mishra***

CFD Application on Food Industry; Energy Saving on the Bread Oven

CFD MODELLING FOR SWIRL DIFFUSER AND ITS IMPLICATIONS ON AIR CHANGE EFFECTIVENESS ASSESSMENT TO GREEN STAR'S IEQ-2

How To Improve Energy Efficiency In A Data Center

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

Impacts of Perforated Tile Open Areas on Airflow Uniformity and Air Management Performance in a Modular Data Center

State of the Art Energy Efficient Data Centre Air Conditioning

Managing Data Centre Heat Issues

Numerical Simulation of the External Flow Field. Around a Bluff Car*

Natural Convection. Buoyancy force

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

Best Practices in HVAC Design/Retrofit

DCIM Data Center Infrastructure Monitoring

CFD Modelling of a Physical Scale Model: assessing model skill. Kristof Verelst FHR, Antwerp

Best Practices for Wire-free Environmental Monitoring in the Data Center

NUMERICAL SIMULATION OF FLOW FIELDS IN CASE OF FIRE AND FORCED VENTILATION IN A CLOSED CAR PARK

Andrea Basti* Italian National Institute of Nuclear Physics (INFN) Gran Sasso National Laboratory (LNGS) *Research Grant Holder

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

HEAT TRANSFER IM LECTURE HOURS PER WEEK THERMODYNAMICS - IM _1

Enclosure and Airflow Management Solution

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

DSRQ - DSRSQ - DSRSQ-THERM

Statement Of Work. Data Center Power and Cooling Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary

Using thermal mapping at the data centre

How Row-based Data Center Cooling Works

Transcription:

Data Centre Best Practises Workshop Using Computational Fluid Dynamics (CFD) for improving cooling system efficiency for Data centers Shishir Gupta 17 th March 2009

You are Here Introduction to CFD Data Centre Case Study Geometrical Details CFD while designing of HVAC system CFD during installation of Data Centre CFD for maintenance of Data Centre Feedforward System

Introduction to CFD Computational (having to do with mathematics & computation) Fluid Dynamics (the dynamics of things that flow) CFD is built upon fundamental physics equations: equations of motion and conservation. CFD applications range from numerical weather prediction to vehicular aerodynamics design. CFD applications are linked with advances in computing software and hardware. CFD software is characterized by the physical models in the software. Fine-scale CFD applications closely match the true geometry of the physical objects and processes being modeled.

What is CFD? Fluid Mechanics Fluid Problem Comparison& Analysis Mathematics Physics of Fluid Navier-Stokes Equations Numerical Methods Discretized Form C F D Geometry Simulation Results Computer Computer Program Grids Programming Language

Why use CFD? Cost Time Scale Information Repeatable Security Simulation(CFD) Cheap Short Any All All Safe Experiment Expensive Long Small/Middle Measured Points Some Some Dangerous

Where use CFD? Chemical Processing HVAC(Heat Ventilation Air Condition) Hydraulics Aerospace Automotive Biomedical Power Generation Sports Marine Chemical Processing reactor vessel - prediction of flow separation and residence time effects. Hydraulics HVAC Streamlines for workstation ventilation

Where use CFD? Aerospace Chemical Processing HVAC Hydraulics Aerospace Automotive Biomedical Power Generation Sports Marine Biomedicine Automotive Temperature and natural convection currents in the eye following laser heating.

Where use CFD? Chemical Processing HVAC Hydraulics Aerospace Automotive Biomedical Power Generation Sports Marine Sports Power Generation Flow around cooling towers Marine

You are Here Introduction to CFD Data Centre Case Study Geometrical Details CFD while designing of HVAC system CFD while installation of Data Centre CFD for maintenance of Data Centre Feedforward System

CFD Case Study for Data Centre

Introduction to the Case Study Case Study is taken from one of the project that we did for a Data Centre in India The case study includes what we did for the client also extends it for what could have been done for the same project using CFD There were two software applications used for the project : OpenSource CFD platform of OpenFoam and commercial CFD package of Fluent Both packages produced about the same results, in this presentation the results from OpenFoam are being shown

Case Description The analyzed Data Centre is rectangular with of area 516m 2 and height 3.35mt Cooling is to be provided using raised flooring layout and demarcation is done for Cold Aisle and Hot Aisle The sources of heat gain inside the data centre are listed below: Heat gain through exterior walls accounting for thermal resistance of the wall Heat gain from Server Racks, 154 Server racks each providing about 8 KW combine to about 1.26 MW Three fans of about 500CMH were assumed to transport air from cool aisle to hot aisle in each rack unit (Since detailed blade specification is not known)

HVAC System Specification 10 CRAC units, 1 Standby Specification: Each CRAC unit of 30,585 CMH Cooling capacity of Each Rack is 150 KW Temperature of supply air is 9.4 o C Return Air opening area (On top surface): 2.23 m 2 Supply Air Diffuser (Cold Aisle) Specifications: Dimension of 600mm X 600mm 70% open area 1 supply diffuser per rack (Total 154) Supply air velocity can be controlled using under floor fan Return Air Diffuser (Hot Aisle) Specification: Dimension of 600mm X 600mm 50% open area Total no. of diffusers: 242

Objective of the Study To maintain recommended temperature by ASHRAE for Class 1data centre The recommended atmosphere is defined as: Temperature of 20 o C - 25 o C Relative humidity of 40% - 55 % The allowed change in temperature should be less than 5 o C/hr

Recommended Operating Conditions

Design Parameters Number of CRAC s Location of CRAC s Velocity of supply air

You are Here Introduction to CFD Data Centre Case Study Geometrical Details CFD while designing of HVAC system CFD while installation of Data Centre CFD for maintenance of Data Centre Feedforward System

Base Case Design CRAC Units (11 Nos.) Return Diffusers Supply Diffusers Server Racks False Flooring False Ceiling Isometric View of the Designed Data Centre

Case Study Cont COLD AISLE Diffusers HOT AISLE Diffusers CRAC Units (11 Nos.) Server Racks Top View of the Designed Data Centre

CFD Simulation of Base Case Temperatures across Y-Z plane

Temperature Contour Temperature Profile at vertical planes along the racks and cold aisle.

CFD Simulation of Base Case Temperatures across X-Y plane

Temperature Contour Temperature Profile at Horizontal planes along the racks and cold aisle. Lets look at the mid-plane contour in more detail..

Temperature Contour in Middle Plane The temperature contour at the Horizontal plane at the middle portion of the rack

CFD Simulation of Base Case Temperatures across X-Z plane

Temperature Contour Temperature Profile at the middle plane is showing most uneven distribution. Lets analyse the middle plane in detail

Temperature Contour in Middle Plane The temperature contour at the vertical plane at the middle portion of the rack

Velocity Vectors in Middle Plane The Velocity Vectors at the vertical plane at the middle portion of the rack

Conclusion from the base case CFD 1. The Average temperature on the rack surface at the cold Aisle side is 15 2. The temperature at Cold Aisle is varying from 12 to 17 3. The Average temperature on the rack surface at the Hot Aisle side is 27 4. The temperature at Hot Aisle is varying from 18 to 32 5. The simulation shows that a good number of servers are experiencing temperature well above and below the ASHRAE recommended temperature levels 6. Short circuiting of cold air is clearly visible in the simulation

Optimizing number of CRAC units & Supply Air Velocity 1. Maximum heat load : 154 X 8 = 1264 KW (1.26 MW) 2. Heat capacity of each CRAC : 150 KW 3. Minimum number of CRAC required: [8.4] = 9 4. The system was designed with 9 CRAC units and velocity of supply air was adjusted to avoid short circuiting and temperature stratification 5. In this case the velocity of 2.2 m/s is coming out to be higher 6. The simulation was conducted with velocity of 1.6, 1.7, 1.8, 1.9, 2.0 & 2.1 m/s 7. The results with 1.8 m/s showed best results

Temperature Distribution with 9 CRACs & 1.8 m/s The temperature contour at the vertical plane at the middle portion of the rack

Velocity Vectors with 9 CRACs & 1.8 m/s The Velocity Vector at the vertical plane at the middle portion of the rack

Results of improved design CFD 1. The Average temperature on the rack surface at the cold Aisle side is 16 2. The temperature at Cold Aisle is varying from 13 to 17 3. The Average temperature on the rack surface at the Hot Aisle side is 23 4. The temperature at Hot Aisle is varying from 19 to 29 5. Short circuiting of cold air is reduced to a substantial level, however still prevalent 6. The simulation shows that a most of the servers are experiencing temperature as recommended by ASHRAE

Conclusion Using Computational Fluid Dynamics the system was designed to reduce to 90% of original design, thus bringing about first cost saving of 10% in the capital cost. The new system uses less energy and produces better result than the initial design based on thumb rules

You are Here Introduction to CFD Data Centre Case Study Geometrical Details CFD while designing of HVAC system CFD during installation of Data Centre CFD for maintenance of Data Centre Feedforward System

Case Description The capacity of this data centre of of 42 X 154 = 6,468 Server Blades 4,000 server blades are to be installed 1,000 servers are by Dell, 2,000 by IBM & 1000 by Sun The design variables are: Number of CRAC units Which CRAC unit should be operational Location of Server Blades in the racking system Velocity of supply air inlet

CFD Simulation Setup The power requirement of 3000 Server is minimum 713 KW 5 CRAC (750KW) are minimum number of units which can provide the required tonnage The CFD simulation were conducted with various locations of Servers, CRAC s and Supply air velocity The best result was found with following parameters: Top Racks are empty Alternative CRACs are operating Velocity of Supply air is 1.2 m/s

CFD Simulation Results Server Positions in the Racks

CFD Simulation Results Operational CRAC s

Temperature Distribution with 5 CRACs & 1.2 m/s The temperature contour at the vertical plane at the middle portion of the rack

Velocity Vectors in Middle Plane The Velocity Vectors at the vertical plane at the middle portion of the rack

Calibration during Installation Temperature Sensors The Result from CFD shall be compared with average reading shown by temperature and velocity sensors If there is any difference, the modeling shall be improved to arrive at the actual values.

You are Here Introduction to CFD Data Centre Case Study Geometrical Details CFD while designing of HVAC system CFD during installation of Data Centre CFD for maintenance of Data Centre Feedforward System

Feedforward System Whenever capacity of the data centre is to be increased, the design parameters like number of CRACs and supply air velocity should be determined using CFD If the capacity ramp up is not that frequent than CFD simulation can be conducted at that stage to arrive at design parameters If ramp-up/ramp-down is very frequent then a custom made CFD code should be developed using OpenSource Libraries. This would enable data centre administrator to conduct CFD s for his data centre and analyze various design options

Conclusion CFD can help design and operate the data centre HVAC system with optimum efficiency Thank You