When the Power Fails: Designing for a Smart Meter s Last Gasp



Similar documents
Power supplies. EE328 Power Electronics Assoc. Prof. Dr. Mutlu BOZTEPE Ege University, Dept. of E&E

7-41 POWER FACTOR CORRECTION

DC/DC power modules basics

Designing DC/DC Converters to Meet CCITT Specifications for ISDN Terminals

AC/DC Power Supply Reference Design. Advanced SMPS Applications using the dspic DSC SMPS Family

3-Phase Synchronous PWM Controller IC Provides an Integrated Solution for Intel VRM 9.0 Design Guidelines

Rectifier circuits & DC power supplies

Power supply output voltages are dropping with each

= V peak 2 = 0.707V peak

The leakage inductance of the power transformer

EMI and t Layout Fundamentals for Switched-Mode Circuits

ELECTRONIC POWER SYSTEMS

Design of an Auxiliary Power Distribution Network for an Electric Vehicle

National Semiconductor Power Products - Seminar 3 (LED Lighting)

5W LED Lump Module Design with FT831B

Introduction to Power Supplies

Input and Output Capacitor Selection

Powering Integrated Circuits (ICs), and managing ripple voltage as it relates

Power Electronic Circuits

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

Line Reactors and AC Drives

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

The full wave rectifier consists of two diodes and a resister as shown in Figure

Keywords: input noise, output noise, step down converters, buck converters, MAX1653EVKit

AN486: High-Side Bootstrap Design Using ISODrivers in Power Delivery Systems

Homework Assignment 03

DC-DC Converter Basics

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

AND8147/D. An Innovative Approach to Achieving Single Stage PFC and Step-Down Conversion for Distributive Systems APPLICATION NOTE

Article from Micrel. A new approach to the challenge of powering cellular M2M modems By Anthony Pele Senior Field Applications Engineer, Micrel

Properties of electrical signals

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

Fairchild On-Line Design Tool: Power Supply WebDesigner Step-by-Step Guide

Application Note, Rev.1.0, September 2008 TLE8366. Application Information. Automotive Power

High Voltage Power Supplies for Analytical Instrumentation

AN2872 Application note

Series AMLDL-Z Up to 1000mA LED Driver

AN-8019 Reliable USB Modem Design Using the Combination of an Integrated Load Switch and a Buck Converter

Design Considerations for an LLC Resonant Converter

Power Management & Supply. Design Note. Version 1.0, Nov DN-EVALMF2ICE2A CoolSET 35W DVD Power Supply with ICE2A265.

The Flyback Converter

TOPOLOGIES FOR SWITCHED MODE POWER SUPPLIES

28 Volt Input - 40 Watt

ECEN 1400, Introduction to Analog and Digital Electronics

High Performance ZVS Buck Regulator Removes Barriers To Increased Power Throughput In Wide Input Range Point-Of-Load Applications

AN ISOLATED GATE DRIVE FOR POWER MOSFETs AND IGBTs

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

Power Supplies. 1.0 Power Supply Basics. Module

Chapter 4. LLC Resonant Converter

TM MP2305 2A, 23V SYNCHRONOUS RECTIFIED, STEP-DOWN CONVERTER

MP2365 3A, 28V, 1.4MHz Step-Down Converter

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

LM1084 5A Low Dropout Positive Regulators

The D.C Power Supply

Bridgeless PFC Implementation Using One Cycle Control Technique

Design A High Performance Buck or Boost Converter With Si9165

Kit Watt Audio Amplifier

Understanding SMD Power Inductors. Application Note. July 2011

Lab 3 Rectifier Circuits

Switched-mode buck converter with voltage mirror regulation topology

650W Single Output Power Supply

electronics fundamentals

Single-Stage High Power Factor Flyback for LED Lighting

Power Quality. Uninterruptible Power Supply

Modeling and Analysis of DC Link Bus Capacitor and Inductor Heating Effect on AC Drives (Part I)

Solar Energy Conversion using MIAC. by Tharowat Mohamed Ali, May 2011

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Simple PWM Boost Converter with I/O Disconnect Solves Malfunctions Caused when V OUT <V IN

How to design SMPS to Pass Common Mode Lightning Surge Test

FPAB20BH60B PFC SPM 3 Series for Single-Phase Boost PFC

High Efficiency Battery Charger using Power Components [1]

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

Output Ripple and Noise Measurement Methods for Ericsson Power Modules

Single Output Switching Power Supply

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Relationship between large subject matter areas

Current and Temperature Ratings

How To Make A Power Supply For A Flyback Power Supply

FEBFL7701_L30U003A. 2.4W LED Ballast Using FL7701. Featured Fairchild Product: FL7701

Precision Diode Rectifiers

Antec TruePower User's Manual

VICOR WHITE PAPER. The Sine Amplitude Converter Topology Provides Superior Efficiency and Power Density in Intermediate Bus Architecture Applications

Application Report SLVA057

LDS WLED Matrix Driver with Boost Converter FEATURES APPLICATION DESCRIPTION TYPICAL APPLICATION CIRCUIT

AND8247/D. Application Note for a 5.0 to 6.5 W POE DC to DC Converter APPLICATION NOTE

Chapter 6: Converter circuits

SELECTION GUIDE. Nominal Input

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Tamura Closed Loop Hall Effect Current Sensors

Considerations When Specifying a DC Power Supply

Unit/Standard Number. High School Graduation Years 2010, 2011 and 2012

Chapter 14: Inductor design

Welcome to the combined product training module of Linear Technology and Wurth Electronics about their efficient design solution for DC/DC Flyback

Understanding Power Impedance Supply for Optimum Decoupling

DC Voltage Regulation by Buck Converter Applicable for Stand Alone Micro Hydro Power Generation

Phase-Control Alternatives for Single-Phase AC Motors Offer Smart, Low-Cost, Solutions Abstract INTRODUCTION

Cree PV Inverter Tops 1kW/kg with All-SiC Design

UMEC International Corporation

Ultra Low Profile Silicon Capacitors (down to 80 µm) applied to Decoupling Applications. Results on ESR/ESL.

Silvertel. Ag9800M. 1. Features. 2. Description. Miniature PoE Module. Small SMT package. IEEE802.3af compliant. Low cost

Transcription:

When the Power Fails: Designing for a Smart Meter s Last Gasp Daniel Pruessner 1/10/2012 5:25 PM EST Overview Smart meter designers have an unusual predicament: The meter is powered from the same bus that the meter is monitoring. When power is lost, the meter must record state information to flash memory or send out a wireless signal the meter s last gasp. Some utilities also desire to disconnect subscribers from the grid during power outages so that the inrush demands are minimized when power is ultimately ly restored. Disconnecting the subscriber after power is lost also requires stored energy in either electrical or mechanical form. The problem of efficiently and cost-effectively providing hold-up energy typically falls to power supply designers. Here we will review three options a power supply designer has to solve this problem and evaluate their benefits and costs in a flyback switch-mode power supply. The Circuits Figure 1 shows a basic off-line flyback circuit. The supply accepts 85VAC-265VAC and generates a single 3.3VDC, 5W output. Figure 1: Basic flyback schematic with highlighted locations for energy storage.

Let us set the holdup requirement of the load to be 50% power (2.5W) for 0.5s, or 1.25J. Three sections where energy can be stored (A, B, and C) are highlighted in the schematic. Option A stores the hold-up energy in the high voltage capacitor, Cbus. Option B stores the energy in a 20V intermediate voltage capacitor with a down-stream DC/DC buck regulator that steps down the voltage to the load working voltage at 3.3V. Option C is simpler and stores energy in a large capacitor at the output. Electric Potential Energy Since all the options involve storing energy as electric potential in a capacitor, we should review the relationship of voltage, capacitance, and potential energy shown in the following equation: To calculate a change in the potential energy for a given change in the voltage across the capacitor, we have: where V f is the final voltage, and V 0 is the initial voltage. The change in voltage for a given change in potential energy is: where U f and U 0 are the final and initial potential energy, respectively. Option A - Primary-Side Capacitance The first option is to increase the capacitance of the high voltage bulk electrolytic capacitor on the primary side, C bus.

Figure 2: Scope grab measuring primary-side energy storage in a 5V flyback supply. Holdup is for 22ms. This capacitor is typically sized to store just enough energy to continue power conversion during the AC cycle valleys for a full-wave rectified input this is 1/120 s, or 8.3ms. When voltage from the line disappears, the converter will continue to run and consume energy from C bus. The voltage on C bus will eventually reach a point where the volt-age cannot ramp sufficient current through the primary-side inductor to sustain the output. The voltage on the auxiliary output, from which the controller draws its power, will also drop to the controller s under-voltage lock-out level. Once this happens, the controller will shut o, and the output will fall to zero. This process is shown in Figure 2. The supply will need to hold-up the output under all conditions, so we will focus on the worst-case: when source power is disconnected shortly after the AC zero-crossing at lowline input. Since the supply will draw half-power during hold-up, the supply will operate normally it will have enough voltage to impose across the inductor to reach the required primary-side peak current down to 70% of the minimum input voltage requirement. We can therefore estimate that the supply will operate down to 70V on C bus. We can use (2) to solve for the capacitance needed to provide the 1.25J of hold-up energy. We set V 0 to the minimum rectified AC line voltage because the bus ripple voltage will be negligible when the bulk capacitance is large: This is a very large amount of capacitance needed and these capacitors need to be rated at a minimum of 400V. One benefit to storing energy in the primary-side is that a large amount of energy can be stored if the minimum line voltage is fairly high. For instance, if the minimum line voltage were 190V AC, then the same hold-up would require

only 68 F, which is much more manageable! Figure 3 shows the holdup-time curve for this supply. Considerations Storing energy in the primary-side can be expensive. Large-valued high-voltage capacitors can get pricey, and the leakage current through them increases with voltage and value. Most designs try to minimize the primary-side loop to minimize electromagnetic compliance problems. Using very large capacitors (30mm diameter) may make this difficult. Figure 3: Calculated holdup time for a 85-265VAC flyback supplying 2.5W power after line disconnect. Although it is not shown above, the efficiency of the power supply must also be taken into consideration. Energy stored in the primary-side must be processed through the converter (the switch, inductor, secondary-side diodes), and it will be decreased by the efficiency of the converter. Many flyback converters are 75%-85% efficient, so the primary-side energy will need to increased up by 20%. Option B - Intermediate Voltage Option B is to add a secondary DC/DC regulator on the isolated side of the supply. A synchronous buck regulator fulfills this function with minimal parts: several products exist in the market that integrate the controller with high-side and low-side switches and drivers. The buck regulator would operate at a higher frequency than the flyback and would provide lower voltage ripple to the load. Holdup energy is stored at an intermediate voltage on the secondary side. Since the secondary side is regulated, this provides a less varied quantity of stored energy. This is

in contrast with storing energy in the primary-side, where the line voltage may vary and the holdup energy will vary with the line voltage squared. The energy storage in the secondary capacitor is straight-forward: where V iv is the intermediate voltage and C iv is the intermediate-voltage capacitance feeding the DC/DC converter. In flyback designs current only flows through the secondary of the transformer during part of the switching cycle. This means that the output current ripple is very large on a RMS vs. DC basis, and it is up to the output capacitor to smooth the time-varying current into DC. Capacitors need to be rated for the heating that is caused by the parasitic resistance (effective series resistance, or ESR) that impedes the current ripple. This can frequently lead to over-sizing the output capacitors to meet end-product lifetime or MTBF goals. With the secondary regulator, the current draw from the intermediate voltage will be a fraction of the load current. For our example, we set V iv B 20V. In this case, full-load DC draw of 1.52A would draw 0.25A from the 20V rail. Because of the significantly reduced current (and therefore current ripple), C iv can be sized based on the hold-up energy requirement and will have insignificant heating. Figure 4 shows the extra components for the secondary regulator. Figure 4: Option B Schematic. Secondary DC/DC converter is a buck and requires an additional inductor and capacitor. Considerations A secondary-side regulator will provide much lower volt-age ripple than a standard flyback output will. The additional parts will add to BOM or PCB space costs; how-ever, these parts can all be sourced as SMD components. The regulated intermediate voltage will provide a more re-liable minimum and maximum holdup time compared to primary-side energy storage. Option C - Supercapacitor

The final option is to store energy directly in the load capacitors. Supercapacitors are very dense capacitors both in terms of capacitance-per-volume and capacitance-per-dollar. This makes them well suited for storing hold-up energy directly at the output. Many supercapacitors are designed for low voltage: 2.3V to 4V. To store 1.25J at 3.3V, about 1.1F of capacitance will be required. This will hold the output within 10% for 0.5s. At boot-up the capacitors will look like a short on the output. Many modern flyback controllers have built-in over-load and short-circuit protection. These features will need to be slowed down in order for the supply to boot properly. Unfortunately, this will also slow down the feed-back of the supply the gain bandwidth of the supply is dependent upon the output capacitance. Considerations Because the output is regulated, this option will also have reliable minimum and maximum holdup times. As mentioned, booting into a large capacitance can pose a challenge for protection features and for sequencing with other supplies that may exist in the meter. Conclusions Each option for storing energy requires extra or specialized parts. Figure 5 shows the parts and cost comparison for each option. Option Parts Cost (@ 10k units) Primary side 400V 560uF capacitor (less $0.20 of the $3.26 10uF needed for other designs) Intermediate 1600uF capacitor, FAN2103 $2.04 Voltage DC/DC, 10uH inductor Supercapacitor 2x2F, 2.4V supercapacitor $3.12 Figure 5: Cost comparison of options Storing energy in the primary-side is the simplest way to increase hold-up time; however, it is the least robust solution with the hold-up time varying more than 1:100 across the line range. Storing energy in the output capacitors is also fairly straight-forward, provided that the application can accommodate the relaxed protection features. The supply will have slower over-load protection and short-circuit protection in order to boot up into the large output capacitance. Finally, storing energy in an intermediate voltage is the most complicated it requires the design of an additional powertrain. However, the benefits are significant; the sup-ply will:

be responsive, have a well defined holdup time, and will be 30% cheaper versus the other storage options. About the Author Daniel Pruessner is a graduate of the University of Texas at Dallas, where he received his BSEE. He worked in power transmission and distribution at the Dow Chemical Com-pany before joining Fairchild Semiconductor in 2009. He is a part of Fairchild s Americas Global Power Resource Lab, where he helps customers solve power supply problems. He is active in designing off-line switch mode power supplies for smart meter, lighting, and consumer electronics applications.