Richard Sweetser, Principal Investigator, EXERGY Partners Corp. Email: rsweetser@exergypartners.com, Phone: 703.707.0293

Similar documents
The Role of Distributed Generation and Combined Heat and Power (CHP) Systems in Data Centers

Specialty Environment Design Mission Critical Facilities

DOE Data Center Energy Efficiency Program

GLOBACON 05 HVAC Systems for Cogen

Data Center Combined Heat and Power Benefits and Implementation. Justin Grau, Google Inc. Sam Brewer, GEM Energy

CHP Strategies and Options / Stored Energy ENERGY SYMPOSIUM April8, 2014 Reading Country Club

How To Evaluate Cogeneration

Combined Heat & Power (CHP) UGI Webinar. Presented By: Barry Wentzel, UGI Utilities Eric Burgis, Energy Solutions Center June 18, 2013

Green Development of Infrastructure and Campus: Modern Practice and Approach in District Heating and Cooling System

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Increasing Energ y Efficiency In Data Centers

Data Center Analysis and Design Analysis of SU s Green Data Center Performance

Enabling an agile Data Centre in a (Fr)agile market

CRITICAL COOLING FOR DATA CENTERS

Combined Heat & Power. Discussion with Connecticut Energy Advisory Board. February 23, 2010

Update of Financial Incentives for Promoting New and Renewable Energy in the U.S. Cary Bloyd EGNRET-38 Wellington, New Zealand June 18-19, 2012

Energy Efficiency and CHP Opportunities for Data Centers

Data Center Combined Heat and Power (CHP): Benefits and Implementation

THE WORLD S MOST EFFICIENT DATA CENTER

Data Center Equipment Power Trends

Why Data Center Design and Innovation Matters

COMPREHENSIVE 5-DAY TRAINING PROGRAM FOR ENERGY MANAGERS / SEMINAR OUTLINE

This presentation is posted for public use. ACEEE does not endorse any product or service.

FEAR Model - Review Cell Module Block

Energy Benchmarking Report for Lafayette Elementary School Bound Brook, NJ

Green Data Centre Design

University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008

ENERGY SERVICES ENVIRONMENTAL BENEFITS AND ENERGY SAVINGS

Energy Action Plan 2015

Large Energy Savings Per Installation VFDs for Large Chillers

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

District Heating & Cooling in Helsinki

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Energy Efficiency and Availability Management in Consolidated Data Centers

Metering for today s systems

DC Pro Assessment Tools. November 14, 2010

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

CHP & ENVIRONMENTAL COMMODITIES: MARKET & POLICY UPDATE FOR MONETIZING RENEWABLE ENERGY CREDITS FROM CHP PROJECTS. Thomas Jacobsen October 2012

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Dharam V. Punwani President, Avalon Consulting, Inc. Presented at Turbine Inlet Cooling Association Webinar April 9, 2014

National Grid s Energy Efficiency Programs

Living Green in the Data Center. Dominick Regina Associate Director, Infrastructure Services

80% of. 50% of. 30% of. 67% of enterprises. Environmental and business demands are converging

World s Greenest High Performance Data Center

Figure 1: Comparison of Projected Electricity Use,

Data Center Planning. PUE Overview

Data Centers a focus of information processing energy efficiency

Source: EIA Natural Gas Issues and Trends 1998

RAPID ENERGY MODELING FOR EXISTING BUILDINGS:

Master Infrastructure Plan Update

Energy Saving by ESCO (Energy Service Company) Project in Hospital

Boilers and cogeneration/trigeneration. Abhi Sawant Business Development Manager Simons Green Energy

Combined Heat and Power: Economic, Proven, Reliable, Clean

ABSTRACT DCMCCT PROJECT OVERVIEW

Performance Contracting

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Energy Efficient High-tech Buildings

GREEN DATA CENTER DESIGN

Overview of Green Energy Strategies and Techniques for Modern Data Centers

THE EUROPEAN GREEN BUILDING PROGRAMME. Technical Module on Combined Heat and Power

Micro-Turbine Combined Heat & Power Generators (CHP) Cold Climate Applications 2014 Polar Technology Conference Richard S.

University of Maryland College Park District Energy System. IDEA Campus Energy Conference February 9, 2012

CHP - The Business Case

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

General Recommendations for a Federal Data Center Energy Management Dashboard Display

LEVEL 3 DATA CENTER SERVICES IN OMAHA, NEBRASKA HIGH AVAILABILITY ENTERPRISE COMPUTING BUSINESS DEMANDS IT. LEVEL 3 DELIVERS IT.

Growing your greenhouse business faster with gas engines.

Data Center Technology: Physical Infrastructure

Power and Thermal Services. Power and Thermal Services

Identifying Energy Saving Opportunities in the Data Center

Sustainability. at SUNY Empire State College

Energy Strategic Plan Los Angeles Community College District Community College League Conference

NATURAL GAS IN COMMERCIAL BUILDINGS

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Improving Sustainability in Campus Data Centers Click To Edit Master Title Style

ANALYSIS OF THE ADMINISTRATION S PROPOSED TAX INCENTIVES FOR ENERGY EFFICIENCY AND THE ENVIRONMENT

Current and Future Uses of Renewable Natural Gas A gas utility perspective

Retrofitting Affordability

Triple Bottom Line Effects on People, Planet, and Profits. Through Key Opportunities in:

RENEWABLE ENERGY STANDARDS AND

ENERGY AUDITS (OR SURVEYS) & ENERGY MANAGEMENT PROGRAMS SECTION B

Creating Incentives for Electricity Providers to Integrate DER

HPC TCO: Cooling and Computer Room Efficiency

Silicon Valley Power Data Center Program Rebate Application

GENERATION TECHNOLOGY ASSESSMENT

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

1.4 PUE The New Mandate for Federal Data Center Energy Efficiency. Strategic Sustainability Performance Plan (SSPP)

Tim Facius Baltimore Aircoil

TEXAS A&M UNIVERSITY Utilities & Energy Services

IMMERSION MANAGEMENT SERVICE KG

PROCUREMENT GUIDE: SELECTING A CONTRACTOR/PROJECT DEVELOPER

Renewable Energy and Energy Efficiency Incentives. Prepared by: David W. Swatosh, CPA

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Pursuing Operational Excellence. Better Data Center Management Through the Use of Metrics

State Clean Energy Fund Support for Renewable Energy Projects

Opportunities for Combined Heating and Cooling Using Data Centres

PECO Smart Ideas for Your Business

Passive & Active Design

Transcription:

Richard Sweetser, Principal Investigator, EXERGY Partners Corp. Email: rsweetser@exergypartners.com, Phone: 703.707.0293 U.S. DOE Industrial Distributed Energy Portfolio Review Meeting Washington, D.C. June 1-2, 2011 1

Executive Summary The truth is that data growth is rapidly outpacing our ability to process, analyze and store the data we re collecting. In fact, enterprise storage needs are increasing by up to 40 percent per year. That means up to 40 percent more equipment; 40 percent more rack space; 40 percent more people; 40 percent more power; 40 percent more budget dollars. Every year. March 2011 Stratecast 2

Executive Summary Data center spaces can consume up to 100 to 200 times as much electricity as standard office spaces. The critical nature of data center loads elevates many design criteria chiefly reliability, high power density capacity and speed to market far above energy efficiency. CHP systems could provide the reliability and power density especially if power and thermal systems are properly integrated. Applying just 100 MWs of advanced CHP power and cooling modules to new data centers would result in 17.3 billion Btus of primary energy savings and 2.3 million tons of CO 2e reduction per year. The Advanced Low Temperature Heat Recovery Absorption Chiller Module will provide the next level of performance and economics that could accelerate the deployment of CHP systems into high reliability data centers of the future. 3

Project Objective Objective: Extensively performance test an absorption chiller beyond previous thermal boundaries to create performance algorithms, create performance calculator for the chiller series covering all UTC model sizes, modularize the system to reduce cost and increase reliability and test the system in the field for one year. Statement of the problem: Hot water-fired single-stage absorption chillers have not been performance tested to meet the low return temperatures of engine prime movers providing no reliable means of optimizing chiller /prime mover performance. Secondly, modularization of chillers with prime movers is not current practice. Finally, field engineered and erected solutions to not meet construction schedule requirements for data centers. Risk: Performance test measurements do not meet the theoretical performance predictions. 4

State of the Art Co-generation systems, also known as combined heat and power, involve the use of a heat engine or power station to simultaneously produce electricity and useful heat.waste heat can be used directly or to supply cooling required by the data center through the use of absorption or adsorption chillers, reducing chilled water plant energy costs by well over 50%. The higher the cooling air or water temperature leaving the server, the greater the opportunity for using waste heat.single stage, lithium bromide desiccant based chillers are capable of using the low grade waste heat that can be recovered from common onsite power generation options including microturbines, fuel cells, and natural gas reciprocating engines. Earlier absorption chiller model operations have experienced reliability issues. Modern controls on newer absorption chiller models, though more complicated, remedy this problem. However, start-up and maintenance of absorption chillers have often been viewed as significantly more involved than that for electric chillers. FEMP Best Practices Guide for Energy-Efficient Data Center Design, Revised March 2011 5

State of the Art 6

State of the Art CHP (power and cooling) systems are not considered by the data center specifying community as viable energy solutions for high reliability data centers. In fact, there are few CHP systems installed in data centers through the marketplace and none of these are replicable. Company Location kw Capacity Prime Mover Fujitsu America Sunnyvale, CA 200 Fuel Cell Guaranty Savings Building Fresno, CA 600 Fuel Cell Flint Energies Service Center Facility Warner Robins, MT 5 Fuel Cell hevron Texaco Corporate San Ramon, CA 200 Fuel Cell Verizon Communications Garden City, NY 1,400 Fuel Cell 30 N LaSalle Office Building Chicago, IL 1,100 Gas Engine Telecommunications Facility Burlingame, CA 120 Microturbine Citibank West FSB Building La Jolla, CA 60 Microturbine WesCorp Federal Credit Union San Dimas, CA 125 Microturbine Verizon Ontario Ontario, CA 360 Microturbine Verizon Pomona Pomona, CA 240 Microturbine Chevron Accounting Center Concord, CA 3,000 Recip. Engine Network Appliance Sunnyvale, CA 825 Recip. Engine Zoot Enterprises Bozeman, GA 500 Recip. Engine AT&T Basking Ridge, NJ 2,400 Recip. Engine Continental Insurance Neptune, NJ 450 Recip. Engine Verizon Communications Garden City, NY 1,400 Recip. Engine Total 12,985 7

Technical Approach Absorption chillers were designed for space conditioning and have not been performance tested to meet the low return temperatures of new generation of engine prime movers coupled with data center specific high chilled water temperature requirement, providing no reliable means of optimizing chiller /prime mover performance. Considering there is no perceived market for CHP based cooling in data centers, there is no reason to assess and/or test these units for low temperature heat sources. We need to study the Carrier/Sanyo unit (heat and mass transfer capabilities) and develop predicted results. The chiller will require extensive parametric testing to prove out performance under all conservable operating conditions. The results will then need to be scaled throughout the family of sizes. Secondly, modularization of chillers with prime movers is not current practice. This is an essential element in moving CHP systems into the data center energy space by driving down cost and delivery times while also driving up reliability. 8

Technical Approach Address scientific/technological approach: Blending small business innovation (Exergy and ICHPS) with the world leader in HVAC (Carrier/UTRC) and demonstrating the technology at the Great Lakes Center for Energy Smart Communities ( GLC ) is the nation s first carbon neutral All Digital Community. Address unique execution attributes: the project team includes market leader in HVAC systems, nationally recognized CHP application experts, using best in class data center designer, and nationally recognized computer expert. 9

Technical Approach Benchmarking 10

Technical Approach - Modularization Modular Prime Mover Modular Thermal Cooling 11

Transition and Deployment Who cares? Data center industry is clearly focused on reducing energy density and cost. Who is the end user? Principle end user is the data center owner, however the key focus must be the data center design engineer who takes the specification risk. How will they use it? The specifying engineer can provide a very energy efficient electric and thermal energy supply for data centers using CHP provided there is little or no risk of failure. Does it improve their mission/capabilities? If the technology works, the specifying engineer is successful by providing a good energy efficient solution to the client who saves money, energy and further greens the data center. What is the technology sustainment model? The Carrier singleeffect low temperature chiller performance mapping will enable the entire chiller family to be applied to all reciprocating engine prime movers opening up this new application for Carrier and stimulating others to investigate this market. 12

Measure of Success If you're successful, what difference will it make? The project has not started and detailed estimates of market penetration have not been made. The parties, however, believe that considerably more CHP systems will be applied than the 24 MW in the DOE database. What impact will success have? Every 100 MWs of advanced CHP power and cooling modules applied to new data centers would result in 17.3 billion Btus of primary energy savings and 2.3 million tons of CO2e reduction per year. How will it be measured? Initial success will be measured during a 12 month M&V period. Ultimate success will be measured near-term through specified CHP systems and long-term by installed CHP systems. 13

Benefits Projected Energy/Environmental Savings Number of Primary Energy CO2e NOx SOx PM10 N2O CHP Systems TBtu per year tons/year tons/year tons/year tons/year tons/year 1 0.011 1,239 4 15 0 0 10 0.11 12,385 37 150 1 1 100 1.10 123,854 368 1,505 14 7 250 2.74 309,634 919 3,762 36 17 500 5.49 619,268 1,838 7,525 72 33 750 8.24 928,902 2,756 11,287 108 50 1,000 10.99 1,238,536 3,675 15,050 143 67 Economic Benefits 20% lower installed cost 30% reduction in field labor (time) 25% reduction in operating cost Project Development Schedule Modular approach allows fast deployment 14

Commercialization Approach Describe commercialization approach: demonstrating the technology at the Great Lakes Center for Energy Smart Communities ( GLC ) is the nation s first carbon neutral All Digital Community will provide a high profile platform for the modularized CHP system. After successful demonstration, it is the intent of D.E.N.T. LLC to move forward in the data center space with aggressive marketing of modular CHP systems for data centers. D.E.N.T. LLC will have strategic allies, in particular EYP Mission Critical (an HP Company), Carrier and the TDB prime mover manufacturer to assist in the commercialization efforts. There are significant details to be completed when the project starts, but key entities including: the Uptime Institute, ASHRAE, DOE FEMP and EPA will be educated regarding the salient benefits of modularized CHP for reliable data center energy supply. 15

Results and Accomplishments Where are you in the project? Project has not started What milestones have you completed? None What accomplishments have been made to-date? None What results do you have to report? None 16

Project Management & Budget How much will it cost? $1,187,155 How long will it take? 3 years max including 1 year field demonstration period. Project task and milestone schedule: We will develop final project plans for the chiller research and development, module integration and development and the field demonstration and a master Gantt chart covering all tasks and subtasks identifying the critical path when the project starts. Project budget (DOE investment, cost share, total) Project Budget FY11 FY12 FY13 FY14 DOE Investment $117,306 $341,527 $205,974 $664,807 Cost Share $50,273 $146,367 $325,707 $522,347 Project Total $167,579 $487,895 $531,681 $1,187,155 17

Path Forward Subtask 1.1 Subtask 1.2 Subtask 2.1 Subtask 2.2 Subtask 2.3 Subtask 2.4 Subtask 2.5 Subtask 3.1 Subtask 3.2 Subtask 3.3 Establish Subcontracts Develop Stage/Gate Process LT Absorber Design Review & Modeling LT Absorber Site Selection and Design Requirements LT Absorber Design Development & Fabrication Drawings LT Absorber Chiller Fabrication LT Absorber Performance Testing LT Absorber Module Design LT Absorber Module Fabrication Drawings LT Absorber Module Fabrication & Functional Testing 18

Path Forward (2 slides max) Subtask 4.1 Subtask 4.2 Subtask 4.3 Subtask 4.4 Subtask 4.5 Subtask 4.6 Balance of Plant Design Development Installation Drawings: Site Layout and Preparation and CHP Plant Installation CHP Plant and ICHM Commissioning CHP Plant Field Performance Measurements Final Report 19

Questions 20