AUTOMATIC CHANGEOVER MANIFOLD Series 915



Similar documents
Regulator Options and Accessories

automatic Changeover regulators and systems manifolds/changeover regulators

KNC Model 3666 Automatic Pressure Calibration System

NITROUS TRANSFER PUMP INSTRUCTIONS

MANI-FLEX AutoSwitch

AIR LINE VALVES AND GAUGES

Veriflo Pressure Regulators

Equipment & gas distribution systems. HiQ. Specialty gas program.

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

Full Technical Catalog For Closed-loop Sampling System

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

A practical guide to restrictive flow orifices

TY-FLO Needle Valves

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

Micro GC Fusion Pre-Installation Checklist

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

Precision Solenoid Valves

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

EDITION 2/2013 CENTRAL GAS SUPPLY HIGH PRESSURE MANIFOLDS AND OUTLET POINTS FOR INDUSTRIAL GASES

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

Recharge Procedure for Telemark TVP-2000 and TVP-3500

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

Parts List: AirHawk II Air Mask

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

VSO MAX HP High Flow Proportional Valve

COUNTERBALANCE VALVES

Morrison Bros. Co. General Product Specifications

MSA Air-Line Respirators

Typical Aluminum GFM Mass Flow Meter

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

NFPA31FuelOilPiping 1 Revised

Packaging Cylinders for Every Application

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Medical Air Systems: Scroll

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Stainless Steel Pipe Fabrication

SIMPLAIR PIPING TOOL

REGULATORS D& HD Series

Standard Hydraulic Piping Flushing Procedure

Float and Thermostatic Traps Series H, C and X

DESIGN STANDARDS SECTION

Mono-Block II Installation & Operation Manual

Engineering Guide and Valve Selection Information

Self Purging Liquid Trap (SPLT ) User s Manual

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Scraper Passage Indicator. Electrical Indicator. Features

INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

LifeASSURE PFS Series Filter Cartridge Integrity Testing

Electronic Flow Switches

Fisher 377 Trip Valve

Why and How we Use Capacity Control

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

In-Line Electronic Flow Switches

Desiccant Air Dryers Heatless, Heated and Heated Blower

Regulator Performance Data

Recreational Vehicles

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Cryogenic Vacuum Pumps

NAVIEN AMERICA INC FITCH AVENUE

Intermodal Containers Presented by Bill Hand Training Coordinator Hazardous Materials Response Team Harris County, Texas

Powers Controls TH 192 S Single Temperature Room Thermostat

Pipeline. Medical Gas Pipeline Products

GTM PORTABLE GAS TRANSPORT. a breakthrough in high pressure gas transports, holding twice as much a comparable steel transports at 40% of the weight

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Complete Systems & Parts Automatic Oiler & Grease Bank

Check Valves & Actuated Valves

Installing a Probe. Typical Installation

Type 3353 Angle Seat Valve

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Excellence through Versatility

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Compact, High-Flow Gas Regulators

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

BERMAD Fire Protection

REGULATORS 175/153 Series

Baumann Mikroseal Control Valve

STORED PRESSURE STAINLESS STEEL

TYPE E Main Valve Sizes 3 /8 through 12

CG PTFE Diaphragm Liquid Transfer Pump

Compressed Gas Cylinder Safety Guidelines

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

All Safe, Inc. Sherwood Master Distributor Toll Free: Fax:

James M. Pleasants Company

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

Transcription:

AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm Remote alarm and auto-dialer options The 915 Series manifold systems are fully automatic. Just set the delivery pressure desired and change cylinders as necessary. There is no need to make any adjustment to the pressure regulators and there is no variation in delivery pressure at or near the changeover setting. These systems are truly automatic and hassle free. Three basic designs are available in either brass or stainless steel. The 915 for high pressure gases and the 915L for use with liquefied gases, such as ammonia, propane, and sulfur hexafluoride, or cryogenic dewars of argon or nitrogen and the 915 LH for use with croyogenic containers in one side and high pressure cylinders on the other side. The 915 Series systems have been designed using components suitable for ultra high purity gas service. Whether brass or stainless steel the system will maintain the integrity of your gas supply while providing a stable delivery pressure. The 915 Series can be used with a single pigtail on each side or multi-station manifold sections on each side(pigtails and manifold headers are ordered separately). It can even be operated with a bulk supply on one side and a cylinder backup on the other. We can customize this system in many ways. The system has lights to indicate which side is in service and which side needs to be resupplied with gas. Additionally, audible and visual alarms are activated each time a changeover occurs. The system requires 120 VAC power. The ultimate extension of these manifold systems is the auto-dialer option. When a changeover occurs, this device will call up to four telephone numbers and play any message prerecorded by the user. The built-in alarms are still activated on-site when this option is employed. This option requires the user to install a dedicated telephone jack at the site. Electronic Control for 915 Series Pressure rating: 915 3000 psig 915L 500 psig 915LH 500 psig one side 3000 psig one side Power requirement: 120 VAC * 915-1-025 brass high pressure automatic changeover manifold, 0-25 psig delivery pressure 915-1-050 brass high pressure automatic changeover manifold, 0-50 psig delivery pressure 915-1-100 brass high pressure automatic changeover manifold, 0-100 psig delivery pressure 915-2-025 stainless steel high pressure automatic changeover manifold, 0-25 psig delivery pressure 915-2-050 stainless steel high pressure automatic changeover manifold, 0-50 psig delivery pressure 915-2-100 stainless steel high pressure automatic changeover manifold, 0-100 psig delivery pressure 915L-1-025 brass low pressure automatic changeover manifold, 0-25 psig delivery pressure 915L-1-050 brass low pressure automatic changeover manifold, 0-50 psig delivery pressure 915L-1-100 brass low pressure automatic changeover manifold, 0-100 psig delivery pressure 915L-2-025 stainless steel low pressure automatic changeover manifold, 0-25 psig delivery pressure 915L-2-050 stainless steel low pressure automatic changeover manifold, 0-50 psig delivery pressure 915L-2-100 stainless steel low pressure automatic changeover manifold, 0-100 psig delivery pressure 915HL-1-025 brass high/low pressure automatic changeover manifold, 0-25 psig delivery pressure 915HL-1-050 brass high/low pressure automatic changeover manifold, 0-50 psig delivery pressure 915HL-1-100 brass high/low pressure automatic changeover manifold, 0-100 psig delivery pressure 915HL-2-025 stainless steel high/low pressure automatic changeover manifold, 0-25 psig delivery pressure 915HL-2-050 stainless steel high/low pressure automatic changeover manifold, 0-50 psig delivery pressure 915HL-2-100 stainless steel high/low pressure automatic changeover manifold, 0-100 psig delivery pressure * Other pressure ranges are possible Option: 915-AD auto-dialer 60

AUTOMATIC CHANGEOVER MANIFOLD Series 915 - Continued PIGTAIL LIST FOR 915 CHANGEOVER MANIFOLD. Pigtails Sets for Brass Changeover Manifolds (2 per set) 915-RPB-CGA* two rigid brass pigtails without 915-RPB-CV-CGA* two rigid brass pigtails with 915-FP601-Y-CGA* two flexible Teflon-lined stainless steel braided pigtails with brass fittings and no 915-FP601-Y-CV-CGA* two flexible Teflon-lined stainless steel braided pigtails with brass fittings and 915-FP604B-Y-CGA* two flexible all stainless steel braided pigtails with brass fittings and no 915-FP604B-Y-CV-CGA* two flexible all stainless steel braided pigtails with brass fittings and Pigtails Sets for Stainless Steel Changeover Manifolds (2 per set) 915-RPS-CGA* two rigid stainless steel pigtails without 915-RPS-CV-CGA* two rigid stainless steel pigtails with 915-FP604B-Y-CGA* two flexible all stainless steel braided pigtails without 915-FP604B-Y-CV-CGA* two flexible all stainless steel braided pigtails with *Specify CGA connection when ordering 915 915 L 915 LH 61

HIGH PURITY SEMI-AUTOMATIC CHANGEOVER MANIFOLD Series 914 The Series 914 semi-automatic changeover manifold is another solution for providing an uninterrupted supply of gas to your instrumentation or process. It incorporates a specially machined two-regulator in one body that simplifies changeover operation and reduces the wall space required. The feed and line regulators are of high purity construction with stainless diaphragms and diffusion resistant construction capable of passing a helium leak rate test of 1x10-9. Available in both brass and 316SS construction, the 914 Series is provided complete with changeover regulator and line regulator installed on a mounting bracket for easy installation. Pigtails and/or manifold sections are ordered separately. The manifold is assembled using the 914 central control section shown on this page and two manifold sections from pages 58 and 59 or a pigtail set from the list below to provide the supply banks. A simple two station semi-automatic manifold commonly used to ensure a continuous supply of carrier gas to a gas chromatograph employs a central control section with a pigtail installed on both inlets. Max. inlet pressure 3500 psig Inlet and Outlet ports 1/4" NPT female Cv 0.06 Operating temperature -40 to +165 F Weight 7.75 lbs. 912 AVA Brass Central Control Section (header only - no pigtails) 914-1-025 line regulator delivery range 0-25 psig 914-1-050 line regulator delivery range 0-50 psig 914-1-100 line regulator delivery range 0-100 psig 914-1-150 line regulator delivery range 0-150 psig Stainless Steel Central Control Section (header only - no pigtails) 914-2-025 line regulator delivery range 0-25 psig 914-2-050 line regulator delivery range 0-50 psig 914-2-100 line regulator delivery range 0-100 psig 914-2-150 line regulator delivery range 0-150 psig Optional Accessories 914-3B Brass Pressure Switches (one each side) 914-3S Stainless Steel Pressure Switch (one each side) 912-AV Audio/visual alarm system Pigtails Sets for Brass Changeover Manifolds (2 per set) 914-RPB-CGA* two rigid brass pigtails without 914-RPB-CV-CGA* two rigid brass pigtails with 914-FP601-Y-CGA* two flexible Teflon-lined stainless steel braided pigtails with brass fittings and no 914-FP601-Y-CV-CGA* two flexible Teflon-lined stainless steel braided pigtails with brass 914-FP604B-Y-CGA* fittings and two flexible all stainless steel braided pigtails with brass fittings and no 914-FP604B-Y-CV-CGA* two flexible all stainless steel braided pigtails with brass fittings and check valve Pigtails Sets for Stainless Steel Changeover Manifolds (2 per set) 914-RPS-CGA* two rigid stainless steel pigtails without 914-RPS-CV-CGA* two rigid stainless steel pigtails with 914-FP604B-Y-CGA* two flexible all stainless steel braided pigtails without 914-FP604B-Y-CV-CGA* two flexible all stainless steel braided pigtails with *Specify CGA connection when ordering 62

ECONOMICAL HIGH PURITY SEMI-AUTOMATIC CHANGEOVER MANIFOLD Series 916 The 916 Series semi-automatic changeover manifold provides a lower cost solution for providing an uninterrupted gas supply to your instrumentation or process. Available in brass or 316 stainless steel, the 916 Series offers the convenience of a simple flip knob to readjust pressures after a changeover and a line regulator to ensure a constant delivery pressure to your system. A pressure switch alarm assembly is available to notify the user that a changeover has taken place, the manifold needs to be set to switch the other way, and the empty cylinders should be changed. The system can simply be used with one pigtail on each side, or connected to larger manifolds such as those shown on pages 58 and 59. Pigtails and/or manifolds sections are ordered separately. Max. Operating Press. Inlet and outlet ports: Operating Temperature: Flow coefficient Cv 916 3000 psig 1/4" NPT female -40ºF to +165ºF 0.07 (0.24 optional)** 912 AVA Model Description Brass Central Control Section (Control section only no pigtails) 916-1-025 line regulator delivery range 0-25 psig 916-1-050 line regulator delivery range 0-50 psig 916-1-100 line regulator delivery range 0-100 psig Stainless Steel Central Control Section (Control section only no pigtails) 916-2-025 line regulator delivery range 0-25 psig 916-2-050 line regulator delivery range 0-50 psig 916-2-100 line regulator delivery range 0-100 psig **For optional 0.24 Cv high flow manifold add "HF" to part number, for example, 916HF-1-050 Options 916-3B brass pressure switch alarm assembly (one each side) 916-4S stainless steel pressure switch alarm assembly (one each side) 912-AVA audio/visual alarm module Manifold mounted in a NEMA4 box add "BX" to part number, for example, 916BX-1-050 Pigtails for Brass Manifolds 916-RPB-CGA* rigid brass pigtail without 916-RPB-CV-CGA* rigid brass pigtail with 916-FP601-Y-CGA* flexible Teflon-lined stainless steel braided pigtail with brass fittings and no 916-FP601-Y-CV-CGA* flexible Teflon-lined stainless steel braided pigtail with brass fittings and 916-FP604B-Y-CGA* flexible all stainless steel braided pigtail with brass fittings and no check valve 916-FP604B-Y-CV-CGA* flexible all stainless steel braided pigtail with brass fittings and check valve Pigtails for Stainless Steel Manifolds 916-RPS-CGA* rigid stainless steel pigtail without 916-RPS-CV-CGA* rigid stainless steel pigtail with check 916-FP604B-Y-CGA* valve flexible all stainless steel braided pigtail without 916-FP604B-Y-CV-CGA* flexible all stainless steel braided pigtail with *Specify CGA connection when ordering 916 BX 63

LASER WELDING AND CUTTING SYSTEMS One of the great advances in a large number of fabricating businesses has been the introduction of laser welding and cutting. The manufacturer of each of the laser systems has their own specifications for the laser and cutting gas transfer systems. The drawing below shows a typical high purity laser gas welding transfer system that has worked very successfully in many laser applications. The system shown contains all of the components required to protect the laser and maintain the gas purity. Contact us with your requirements so that we can design the system that is correct for your laser. LASER CUTTING PRESSURE REGULATOR Series 3840 The 3840 regulator is specifically designed to meet the requirements of the laser cutter. It has fast on-off-on response, high flow capacity, and delivers the pressures required for the job. Whether your source gas is cryogenic or high pressure, this regulator can handle the job. The regulator is actually two regulators in one body - a dome loaded piston regulator and a sensitive diaphragm actuated dome loader built-in. The regulator is supplied with a convenient wall-mounting bracket. FEATURES Rapid on-off-on response even at high flow rates 1/2 NPT female inlet and outlet connections High flow capacity Cv = 1.0 Built-in dome loader regulator Wall mounting bracket provided AND MATERIALS OF CONSTRUCTION Max. Inlet Pressure 3000 psig Outlet Pressure Range 0-500 psig Inlet and Outlet ports 1/2 NPT female Inlet and Outlet Gauge Ports 1/4 NPT female Body brass Dome Loader Diaphragm 316 stainless steel Seat & seals CTFE O-rings Viton Model Del. Press. Gauge Inlet Press. Gauge Description psig psig 3840 none none 3841 0-1000 0-3000 3842 0-1000 0-1000 3841L 0-1000 none 64

HIGH PURITY SEMI-AUTOMATIC CHANGEOVER MANIFOLD Model 912 The semi-automatic changeover manifold is an economic solution for providing an uninterrupted supply of gas to your instrumentation or process. The feed and line regulators and the interconnecting valves are of high purity, metal diaphragm, diffusion resistant construction capable of passing a helium leak rate test of 1x10-9. The manifold is assembled using the central control section shown on this page and a manifolded bank of cylinders on each side or other bulk source to provide a gas supply. A simple two station semi-automatic manifold commonly used to ensure a continuous supply of carrier gas to a gas chromatograph employs a central control section with a pigtail installed on each of the regulator inlets. Pigtails and/or manifold sections are ordered separately. See pages 58 and 59 for manifolds. The operation is simple. The left and right regulators on the control section are set at slightly different discharge pressures between 100-250 psig, so that they discharge only one bank at a time. The line regulator in the center is set at the desired delivery pressure to your system. When the switch-over occurs, and bank #2 is feeding, the first bank of empty cylinders can be replaced. The pressure settings on the regulators are then reversed. When bank #2 is empty, the manifold will automatically switch back to bank #1. The line regulator ensures that a constant delivery pressure and flow is maintained on the common discharge line. Brass Central Control Section(header only - no pigtails) 912-1-025 line regulator delivery range 0-25 psig 912-1-050 line regulator delivery range 0-50 psig 912-1-100 line regulator delivery range 0-100 psig Stainless Steel Central Control Section (header only - no pigtails) 912-2-025 line regulator delivery range 0-25 psig 912-2-050 line regulator delivery range 0-50 psig 912-2-100 line regulator delivery range 0-100 psig Options 912-3B Brass Pressure Switch(installed) 912-3S Stainless Steel Pressure Switch(installed) 912-AVA audio/visual alarm for use with pressure switch Pigtails(set of 2) For brass units 912-RPB-Y-CGA* rigid brass without 912-RPB-Y-CV-CGA* rigid brass with 912-FP601-Y-CGA* flexible Teflon-lined w/brass fittings, without 912-FP601-Y-CV-CGA* flexible Teflon-lined with brass fittings and 912-FPB604-Y-CGA* flexible SS inner core with brass fittings, without 912-FPB604-Y-CV-CGA*flexible SS inner core with brass fittings and For stainless steel units 912-RPS-Y-CGA* rigid SS without 912-RPS-Y-CV-CGA* rigid SS with 912-FP604-Y-CGA* flexible SS inner core with SS fittings, without 912-FP604-Y-CV-CGA* flexible SS inner core with SS fittings and *Specify CGA connection when ordering 912 AVA 65

MANIFOLD TUTORIAL Manifolds are used to connect two or more cylinders of gas together to increase the supply volume available to provide a continuous flow when one cylinder is not sufficient and a tube trailer or other bulk supply is not practical. Manifolds are also used when a single cylinder of gas is not capable of supplying the required flow rate required by a process. WARNING: Never mix gases on a manifold. Only one type of gas should be connected to a manifold. Manifolds are commonly fabricated in a single row configuration designed for wall mounting with a row of cylinders in line beneath or in front of it. Double row manifolds and other custom configurations are available on request. Station valves are used to isolate individual cylinders on a manifold from service. Station valves are recommended for most laboratory applications as they are a valuable backup device in the event of a leaking pigtail or a defective. It is most important that station valves used in high purity gas service be of the diaphragm packless type to maintain gas purity. Many commercial manifolds use packed valves that may cause atmospheric impurities to enter the gas stream as contaminants. Two types of pigtails are used to connect cylinders to the manifold header; rigid pigtails made of brass or stainless steel tubing, or flexible made of stainless steel braided hose with either Teflon-lining or stainless steel inner core. Teflon-lined pigtails are used for routine applications, while the stainless steel inner core pigtails are used for ultra high purity applications. One special note, either rigid pigtails or stainless steel inner core flexible pigtails are recommended for helium and hydrogen because these gases will diffuse through the wall of a Teflon-lined pigtail. Check valves on the cylinder end of each pigtail should always be installed on manifolds used for flammable, toxic, or corrosive gases. In some cases purge assemblies are installed to ensure that highly toxic gases are not released to the working environment during cylinder change outs. Many applications require that gas always be supplied to the process and the flow can not be shut down to replace empty cylinders or must feed gas for long periods when the system is unattended, i.e. helium to a gas chromatography laboratory. In these instances a changeover manifold is the solution. Changeover manifold control sections available in this catalog(see pages 60-63, and 65) can be used with any of the multiple station manifolds or with a single pigtail on each side. 57

BRASS MANIFOLDS FEATURES: Diaphragm packless station valves for high purity 3000 psig service pressure Cleaned for high purity service Standard CGA 346 header pigtail connections These manifolds are constructed of 1/2" brass pipe and fittings screwed together then silver-brazed at each joint. Station valves are the diaphragm packless type for high purity service and are installed with Teflon tape so that they may be easily replaced in the field if necessary. All header pigtail connections are CGA 346 to help ensure that pigtails are installed properly. A plug is inserted in the last tee to allow for the addition of future cylinder stations if required. Suitable brackets for mounting the manifold to a wall are provided. Materials: Header and Valves: Pigtails: Check valves: brass Pressure rating: Header outlet: brass 24" rigid type brass with brass CGA connections. 3000 psig mating connection to pigtail cylinder CGA 910-1-X-CGA* single row manifold without station valves, but with s in the pigtails 910-2-X-CGA* single row manifold with station valves, but no s in pigtails 910-3-X-CGA* single row manifold with station valves and s in the pigtails. 920-1-X-CGA* double row manifold without station valves, but with s in the pigtails 920-2-X-CGA* double row manifold with station valves, but no s in pigtails 920-3-X-CGA* double row manifold with station valves and s in the pigtails. * Complete the model number by inserting the number of cylinders to be connected to the manifold in place of the X and specifying the CGA connection. OPTIONS Flexible pigtails - for Teflon-lined add suffix FP601B-Y for stainless steel inner core add suffix FP604B-Y Outlet connection - 1/2 NPT female - add suffix P8F 58

STAINLESS STEEL MANIFOLDS FEATURES: Diaphragm packless station valves for high purity 3000 psig service pressure(4500 and 6000 psig available) Cleaned for high purity service Standard CGA 346 header pigtail connections These manifolds are constructed of 1/2" 316 stainless steel pipe and fittings screwed together then heliarc welded at each joint. Station valves are the diaphragm packless type for high purity service and are installed with Teflon tape so that they may be easily replaced in the field if necessary. All header pigtail connections are CGA 346 to help ensure that pigtails are installed properly. A plug is inserted in the last tee to allow for the addition of future cylinder stations if required. Suitable brackets for mounting the manifold to a wall are provided. Materials: Header and Valves: Pigtails: Check valves: Pressure rating: Header outlet: 316 stainless steel 24" rigid type 316 stainless steel w/ stainless steel CGA connections. 316 stainless steel 3000 psig mating connection to pigtail cylinder CGA 911W-1-X-CGA* single row manifold without station valves, but with s in the pigtails 911W-2-X-CGA* single row manifold with station valves, but no s in pigtails 911W-3-X-CGA* single row manifold with station valves and s in the pigtails. 921W-1-X-CGA* double row manifold without station valves, but with s in the pigtails 921W-2-X-CGA* double row manifold with station valves, but no s in pigtails 921W-3-X-CGA* double row manifold with station valves and s in the pigtails. * Complete the model number by inserting the number of cylinders to be connected to the manifold in place of the X and specifying the CGA connection. OPTIONS Flexible pigtails - for stainless steel inner core add suffix FP604-Y Outlet connection - 1/2 NPT female - add suffix P8F Manifolds for 4500 or 6000 psig service are also available. 59