Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
|
|
|
- Alberta Horn
- 9 years ago
- Views:
Transcription
1 Document No P25 TH Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat TH0356R POWERS Description The TH 193 HC thermostats are proportional dual output, dual set point, two-pipe (dual one-pipe, low air capacity) or three-pipe (dual two-pipe, high air capacity) sensor controllers. Each thermostat includes a wall mounting plate for installation in a variety of rough-in terminal boxes. Sensitive bimetals respond to temperature changes to modulate control air through a flapper nozzle. As the heating load decreases due to internal heat gains, a dead band of control minimizes energy consumption while the set point changes from 72 F (22 C) heating mode to 78 F (26 C) cooling mode. Two set point dials allow adjustment of the dead band 4 F (2 C) minimum. Air connections are made with 5/32-inch (4 mm) O.D. plastic tubing, directly to the thermostat chassis for retrofit applications or with plug-in adapters (provided with the TH 192 rough-in terminal box or optional accessories), which slide into the wall mounting plate. Features Direct and reverse acting for heating and cooling modes Two separate adjustable temperature set point indicating dials Two highly sensitive bimetal thermostatic elements Fahrenheit or Celsius models Individual field adjustable sensitivity with graduated scale Integral field adjustable limit stops Control pressure test port accessible without removing cover Easily replaceable thermometer, set point dials, filters and restrictor plate Covers available for concealed or exposed thermometers and for either concealed, key, or exposed knob adjustment and set point indication Standard plastic thermostat covers provide desert beige or white finish
2 Optional Design Features Application Fixed temperature limit stops meet government specifications Metal covers available in standard configurations with a variety of finishes Competitor adapter mounting kits available All thermostat chassis available with optional 1/2-inch set point adjustment knobs TH 193 HC thermostats control space temperature and take advantage of the dead band to "float" room temperature between heating and cooling modes while maintaining energy management (maximum economy) and occupancy comfort. TH 193 HC thermostats control valve and damper actuators in building applications that require early morning heat and afternoon cooling. Use TH 193 HC two-pipe (dual one-pipe) thermostats with external restrictors (20 scim, 5.4 ml/sec) where a limited air capacity operates a single valve and/or actuator. Use TH 193 HC three-pipe (dual two-pipe) thermostats where multiple valves and actuators, used with or without high/low limiting controls, require higher air capacities. The thermostats are available with covers that conceal or expose the set point adjustment dials. Figure 1. Typical TH 193 HC Thermostat Application. Piping Figure 2. TH 193 HC Thermostat Dual One-Pipe Connections. Figure 3. TH 193 HC Thermostat Dual Two-Pipe Connections. Page 2
3 Technical Instructions Product Numbers and Ordering Information Chassis See Table 1 for product number and ordering information on TH 193 HC thermostat chassis. Does application require one-pipe or two-pipe connection? a. One-pipe thermostats are low air capacity devices and have only one port connection (R1). This application requires an external restrictor. b. Two-pipe thermostats are high air capacity devices for controlling two or more terminal devices such as damper actuators or valves. This application requires two port connections: supply (S) and return (R1). Is a Fahrenheit or Celsius scale required? Is the heating control direct or reverse acting? Is the cooling control direct or reverse acting? Where is set point adjustment knob located? a. Adjustment knob located at bottom of chassis. b. Adjustment knob on front with 1/2-inch exposed knob. Table 1. TH 193 HC Thermostat Chassis Part Numbers. Connection Type One-Pipe Relay Two-Pipe Relay Set Point Adjustment at Bottom of Cover 1/2" Knob on Cover * at Bottom of Cover 1/2" Knob on Cover * Chassis with Wall Plate Fahrenheit Celsius Heating DA Heating RA Heating DA Heating RA K K K K K K K K K K K K * This feature requires a key set point adjustment cover (or key type cover). See Table K K K K Page 3
4 Covers See Table 2 for product number and ordering information on TH 193 HC thermostat covers. 1. Is the set point adjustment exposed for customer adjustment or concealed to prevent alteration of setting? 2. Is the thermometer exposed or concealed? 3. Is the set point indication exposed or concealed behind cover? 4. Is a plastic or zinc cast metal cover required? a. Plastic covers order 192-2XX. b. Metal covers order 192-3XX. 5. Is finish of cover standard or optional? a. Standard cover is plastic, desert beige color. For white plastic cover option, add "W" suffix code to cover part number (e.g., W). b. Optional covers are plastic or metal and available in a variety of colors. See Table 3. Set Point Adjustment Concealed Table 2. TH 193 HC Thermostat Cover Part Numbers. Cover Configuration Cover Part Number 2 Thermometer Set Point Indicator Standard Plastic Cover Standard Metal Cover Key 1 Concealed Concealed Concealed Concealed Key set point adjustment cover is required for all thermostat chassis with optional 1/2-inch set point adjustment knobs. To order an optional thermostat cover finish, add the appropriate suffix letter listed in Table 3 to the end of the part number listed in Table 2. Page 4
5 Technical Instructions Table 3. TH 193 HC Thermostat Suffix Letters for Optional Cover Part Numbers. NOTE: For color samples, order color reference guide P/N P10. Part Number Suffix Letter None W None Cover Material Plastic (standard) Plastic (optional) Metal (standard) Cover Finish Part Number Suffix Letter Cover Material Cover Finish Desert Beige D Metal No. 10 Special (optional) Bronze White E Brushed Electro-plated Satin Chrome Desert Beige F Sierra Gold A Metal (optional) No. 1 Silver G Brushed Aluminum B No. 5 Satin Chrome H White C No. 7 Light Statuary Bronze Specifications Control action See Table 1 Operating ranges 45 F to 85 F (7 C to 30 C) Supply air pressure, maximum 30 psi (207 kpa) Normal air supply pressure 18 to 25 psi (124 to 172 kpa) Sensitivity adjustment 1 to 4 psi/ F (12 to 50 kpa/ C) Nominal air consumption One-pipe 25 scim (6.8 ml/sec) per side Two-pipe 230 scim (63 ml/sec) per side Temperature response 0.1 F (0.06 C) Temperature Storage temperature -10 C to 140 F (-23 C to 60 C) Ambient operating temperature 40 F to 140 F (4 C to 60 C) Dial graduations 2 F (1 C) Factory settings 72 F (22 C) 7.5 psi (52 kpa) Sensitivity 2.5 psi/ F (31 kpa/ C) Limit stop adjustment 45 F and 85 F (7 C and 30 C) Standard cover Cycolac, desert beige Shipping weight 0.7 lbs. (0.3 kg) Dimensions See Figure 10 Page 5
6 Accessories Operation See the following Technical Bulletins for information on accessories: Technical Bulletin TB 237 Terminal Kits TB 214 Adapter Kits TB 193 Guard Kit TB 241 Test Head Kit TB 167 Restrictors Document Number P P P P The TH 193 HC thermostat is a two-temperature thermostat with two separate outputs. In direct acting control, an increase in temperature increases the control air pressure and a decrease in temperature decreases the control pressure. In reverse acting control, an increase in temperature decreases the control air pressure and a decrease in temperature increases the control pressure. The TH 193 HC provides two separate bimetal elements; one for heating mode and the other for cooling mode. The set point of the two elements determines the window of the dead band. A 4 F (2 C) minimum dead band is standard, where the heating mode set point is 72 F (22 C) and the cooling mode set point is 78 F (26 C). Figure 4 shows a typical application with set points adjusted for a 6 F (4 C) dead band. Figure 5 shows direct acting TH 193 HC output characteristics. As heating increases, the output pressure increases from 0 to 15 psi (0 to 103 kpa). A field adjustable dead band occurs. When the dead band elapses, cooling occurs from 0 to 15 psi (0 to 103 kpa). Figure 4. TH 193 HC Operating Characteristics. Figure 5. TH 193 HC Input/Output Characteristics. Page 6
7 Technical Instructions TH 193 HC Thermostat Details Figure 6. TH 193 HC Thermostat Details. Thermometer Calibration Limit Stop Adjustment 1. Use a test thermometer to read the current room temperature. 2. Place a screwdriver in the center of the thermometer assembly (Figure 6). Carefully rotate thermometer assembly until pointer tip indicates the correct room temperature. NOTE: Avoid breathing on or touching the bimetal spiral since this influences the temperature reading. Thermostat limit stops define the minimum and maximum thermostat set points. The limit stops engage in the set point cam gear teeth and cause interference between the set point cam gear and the adjustment knob gear. To change limit stop settings, use needle nose pliers to pull limit stop between the set point cam gear teeth. Rotate limit stop to its new position. Do not pull limit stop any more than necessary to clear the gear teeth. Changing the limit stop position one gear tooth changes the limit stop setting by 1-1/3 F (0.7 C). Figure 7. TH 193 HC Limit Stop Adjustments. Page 7
8 Sensitivity Adjustment To change thermostat sensitivity, use a flat-blade screwdriver to carefully move the sensitivity slide to the desired position as follows: Graduation closest to the rigid end of the bimetal element 4 psi/ F (50 kpa/ C) Graduation closest to the minimum (MIN) end of the bimetal element 1 psi/ F (12 kpa/ C) Figure 8. TH 193 HC Sensitivity Adjustment. NOTE: If the thermostat sensitivity is adjusted, the thermostat must be recalibrated. Thermostat Calibration The thermostat is factory-calibrated to a control pressure of 7.5 psi (52 kpa) when the set point and the ambient temperature are both at 72 F (22 C). The factory sensitivity setting is approximately 2.5 psi/ F (31 kpa/ C). No adjustments are required if these settings are appropriate for the application. If the thermostat has been tampered with, the sensitivity changed, or is out of adjustment, use the following steps to recalibrate the instrument. Cooling Calibration Step 1 Remove cover using P/N calibration tool. Verify room temperature is between 70 F and 80 F (2 C and 27 C). Step 2 Verify that supply pressure is 18 to 25 psi (124 to 172 kpa). Set cooling dial to room temperature by turning the exposed adjustment knob or using a hex key as shown. Allow thermostat to stand for about five minutes to adjust to the new setting. Page 8
9 Technical Instructions Step 3 Moisten needle and insert P/N test gauge and needle adapter in the test port. Read control pressure. Step 4 If control pressure does not read 7 to 8 psi (48 to 55 kpa), turn calibration screw using P/N calibration tool or 1/8-inch (3.2 mm) wrench until pressure is 7 to 8 psi (48 to 55 kpa). The sensing element is now in calibration and the set point can be changed to the desired room temperature. Heating Calibration Step 1 If not already done, remove cover using P/N calibration tool. Verify room temperature is between 70 F and 80 F (21 C and 27 C). Step 2 Verify that supply pressure is 25 psi (172 kpa). Set heating dial to room temperature by turning the exposed adjustment knob or using a hex key as shown. Allow thermostat to stand for about five minutes to adjust to the new setting. Page 9
10 Step 3 Moisten needle and insert P/N test gauge and needle adapter in the test port. Read control pressure. Step 4 If control pressure does not read 7 to 8 psi (48 to 55 kpa), turn calibration screw using P/N calibration tool or 1/8-inch (3.2 mm) wrench until pressure is 7 to 8 psi (48 to 55 kpa). The sensing element is now in calibration and the set point can be changed to the desired room temperature. Troubleshooting Before troubleshooting thermostat (see Table 4), make certain there is clean, dry supply air at 18 psi (124 kpa) minimum. Use test probe gauge and needle adapter to measure control pressure at thermostat test port. The output pressure test port is accessible without removing the thermostat cover through the 8th opening from the top. For one-pipe thermostats, the port is on the right side. For two-pipe thermostats, the port is on the left side. CAUTION: Figure 9. Accessing Output Pressure Test Port. If you use the wrong test port, thermostat damage can occur and result in replacement of the device. Page 10
11 Technical Instructions Table 4. Troubleshooting Guide. Problem Check Cause Action Control pressure stays at approximately zero Control pressure stays at approximately supply pressure Excessive air leakage from exhaust port on left side of thermostat Air supply Low supply pressure As required Nozzle or flapper Dirt on nozzle or flapper Clean nozzle or replace thermostat Restrictor Clogged restrictor Replace restrictor Calibration Out of calibration Recalibrate Nozzle Clogged nozzle Clean nozzle or replace thermostat Calibration Supply and return line connection Dirt on either supply or exhaust valve seat Connections are interchanged or connection to port is incorrect Alternately close and open nozzle by gently pushing down the bimetal As required Chassis Tube Connector and Restrictor Plate Replacement Remove thermostat chassis from wall. Terminal does not have a ball check valve. NOTE: You must close off the supply air. For example, use a connector with the supply air terminal plugged. Remove two Phillips head screws from connector on back of thermostat chassis. Pull connector out of recess. If necessary, pry connector loose with a screwdriver, but be careful not to damage restrictor plate and gasket. Remove gasket from under connector. Remove restrictor. Remove second gasket from under restrictor. Use restrictor replacement kit P/N to replace gasket, restrictor, and second gasket. NOTE: The restrictor plate is keyed to ensure proper orientation during installation. Remove filters from existing connector and insert in new connector. Or, if filters are dirty, use restrictor replacement kit P/N to replace filters. Use chassis tube connector replacement kit P/N to replace connector and mounting screws. Page 11
12 Service Parts The following chart lists accessory parts and tools available for thermostat service. Description Dial thermometer (-40 F to 140 F, -40 C to 60 C) with pocket case Basic pneumatic calibration kit with thermometer, gauge, squeeze bulb, fittings, and case Part Number Test head kit Calibration tools Test probe to check pressure with cover on Needle probe with 1-1/2" diameter gauge 0-30 psig (0-200 kpa) and calibration/cover wrench Needle probe, no gauge (package of five) /2" diameter gauge, kpa, back connected 1/8" NPT male 1-1/2" diameter compound gauge, 0-30 psig/0-200 kpa, back connected 1/8" NPT male 1-1/2" diameter compound gauge, 0-30 psig/0-200 kpa, bottom connected 1/8" NPT male. Replacement for use with Chassis tube connector replacement kit with mounting screws (material for 10 thermostats included) Restrictor plate replacement kit with filters and gasket (material for 10 thermostats included) Plug-in adapters for quick thermostat removal Straight, blue (package of 20) Straight, white (package of 20) Air link connects adapters for pressure tests (package of 20) Compression ring (package of 100) Elbow (provides quick return for wall surface mounting), blue (package of 20) Elbow (provides quick return for wall surface mounting), white (package of 20) 20 scim (5.4 ml/sec) restrictors for one-pipe systems (package of 5). (1/4", 6.4 mm, O.D. plastic barb unless noted.) Brass coupling, 1/8" NPT (one only) Coupling Tee Pre-piped dual tee for dual one-pipe systems Page 12
13 Document No P25 Description Part Number Replacement thermometer kits, brown (packages of 5) Scale Range Thermostat Model 45 F to 85 F C to 30 C TH0443R1 Model 3 and Up 45 F to 85 F C to 30 C Models 1 and 2 Replacement set point dials (packages of 10) F, Direct Acting Right Side F, Reverse Acting C, Direct Acting C, Reverse Acting F, Direct Acting Left Side F, Reverse Acting C, Direct Acting C, Reverse Acting TH0442R1 Dimensions Figure 10. TH 193 HC Dimensions in Inches (Millimeters). Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Free Energy Band is a trademark of Other product or company names mentioned herein may be the trademarks of their respective owners Deerfield Parkway Buffalo Grove, IL U.S.A. Your feedback is important to us. If you have comments about this document, please send them to [email protected] Document No P25 Printed in the U.S.A. Page 13
Powers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
Powers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
POWERS CONTROL RC 195 Single Input Receiver-Controller
Document No. 155-119P25 RC 195-4 POWERS CONTROL RC 195 Single Input Receiver-Controller Description The RC 195 Single lnput Receiver-Controller is a pneumatic instrument which receives one pneumatic input,
RC 195 Multiple Input Receiver-Controller
Document No. 129-230 RC 195 Multiple Input Receiver-Controller Product Description The RC 195 Multiple Input Receiver-Controller is a pneumatic instrument that can be used as a one input (DA or RA), two
Selection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume)
Code No. LIT-1921710 Issued July 25, 2011 T-4000 Series Accessories Selection Chart T-4000 Series Accessories (Part 1 of 5) ( or Volume) F-100-20 F-300-30 F-300-34 F-300-31 F-300-35 F-500-45 F-300-30 Coupler,
T-4000 Series Pneumatic Room Thermostats
T-4000 Series Pneumatic Room Thermostats Pneumatic Control Manual 717.1 Room Devices Section Product Bulletin T-4000 Issue Date 1285 Features Adjustable Sensitivities and Set Points Individual Set Points
Model 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
POWERS Controls No. 4 Pneumatic Damper Actuator
POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000
T-4000 Series Room Thermostat Adjusting Instructions*
Pneumatic Control Manual 717.1 Room Devices Section Technical Bulletin T-4000 Issue Date 0814 T-4000 Series Room Thermostat Adjusting Instructions* The T-4000 Series Pneumatic Room Thermostats are factory
Installation Instructions 6028.801
DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American
General Information... 2
Pneumatic VAV Reset Volume Controllers CSC 2000 Series Applications Guide General Information... 2 CSC 2000 Series Overview...2 odels and Specifications...3 ounting...4 Connections...4 All Units...4 Beige
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
Many Products...One Source
PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
Submersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
Technical Instructions Document No. 155-021P25 ET 141-5 September 28, 2004. ET 141 High Limit Control Thermostat. Description.
Document No. 155-021P25 ET 141-5 ET 141 High Limit Control Thermostat Description Application The ET 141 high limit control thermostat is duct mounted and has a rigid bulb, bi-metal rod and tube construction.
Installation Manual. TITUS I, II, and IIA Pneumatic Controls Installation, Operation, and Maintenance Manual. (See Figure 3) (Label, See Figure 3)
Installation Manual PNEU-IOM-1.0 5-2-05 IUS I, II, and IIA Pneumatic Controls Installation, Operation, and Maintenance Manual Adjusting Minimum and Maximum Air Flow Airflow limits are printed on the label
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD
HVAC/R GAS TEST GAUGE Hex or Bell Type mounting 5 to00 Psi pressure ranges Steel case and brass internals Use to pressure test all new gas installations for leaks and passing inspection codes. After installing
PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
with installation dynafact boost GAUGE this manual is for use with systems 64050-64054
owners manual with installation instructions dynafact boost GAUGE this manual is for use with systems 64050-64054 GENERAL INSTALLATION PRACTICES This manual is an installation guide for all 1. Banks DynaFact
INSTALLATION INSTRUCTIONS SENSOR OPERATED LAVATORY FAUCET. EBF-85 and EBF-187 Battery Powered, Sensor Operated Lavatory Faucet
EBF-85 I.I. Rev. 3 (08/00) Code No. 0816302 INSTALLATION INSTRUCTIONS SENSOR OPERATED LAVATORY FAUCET EBF-85 and EBF-187 Battery Powered, Sensor Operated Lavatory Faucet Models EBF-85 and EBF-85-R are
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No: 0816407 Rev. 4 (07/12)
PNEUMATIC CONTROLS Selection and Description
PNEUMATIC CONTROLS Selection and Description Carnes pneumatic controlled throttling units are suitable for a standard 20 psi control system and may be supplied with pressure dependent or pressure independent
TYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
TECHNICAL DATA. Dry 122a. November 12, 2013
Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model
Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories
Commercial / HVAC / Plumbing Specification Guide For Pressure & Temperature Instruments & Related Accessories Prepared for Consultant, Design & Specification Engineers Gauges Contractor Gauge (PCT, PCT-LF)
Part I - Installation
400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read
SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A
PAGE 1 OF 6 BASE ASSEMBLY 00 0 EXAMPLE: Component Parts (Small #) Are Included When Ordering The Assembly (Large #). SPECIFY CATALOG NO. AND NO. WHEN ORDERING PARTS 1 02-80-0050 Thrust Bearing (1) 2 05-80-0510
2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
Heat Pump Training System
Refrigeration and HVAC Heat Pump Training System Courseware Sample 85143-F0 Order no.: 85143-00 First Edition Revision level: 02/2015 By the staff of Festo Didactic Festo Didactic Ltée/Ltd, Quebec, Canada
Installation Instructions
Installation Instructions SELECTRONIC DC POWERED PROXIMITY EXPOSED TOILET FLUSH VALVE.,.8,.,./. &.8/. GPF Certified to comply with ASME A.9. 0 AS America, Inc. Exposed Flushometer for -/" Top Spud Bowls
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
Char-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997
Char-Lynn Hydraulic Motor October, 1997 Repair Information Geroler Motor Two Speed 001 27 Retainer inside bore of valve plate bearingless motors only 4 15 16 3 6 35 Parts Drawing 25 2 2 1 19 17 36 40 47
Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters
July 10, 2007 - Page 1 Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters General The Bristol 5453-10G indicating pneumatic pressure controller with 624-II control unit, from Emerson
STABITHERM INSTALLATION & SERVICE BOOKLET
STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow
SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service
RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate
HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate 1 Swing Plate Assembly-RM1-0043 1 Swing Plate Kit-5851-2766 (RM1-0043 plus RM1-1091 gear) CAUTION: Fuser may be hot. Turn off printer, unplug it and allow
Installation Instructions 4662.003
Installation Instructions.00 SINGLE CONTROL KITCHEN FAUCET Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please
I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
Model 5600 & 5600 Econominder
Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................
National Optical & Scientific Instrument Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instrument Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR STEREOSCOPIC MICROSCOPES MODEL NUMBERS 400 400TL
Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.
Picture Item No. Description RO- 0010 Brass Water Feed 1. 3/4" FIP with 1/4" hole 2. Using on R.O. tank RO- O020 Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP RO- 0030 Brass
TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013
Spray Nozzle 11 1. DESCRIPTION Viking Model C-1 Window Sprinklers are non-automatic, open, outside intended for protection of windows, walls, and roofs against exposure fires. The directional discharge
MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com
MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent
Submersion/Insertion Toroidal Sensor
Instruction Manual 228 Sensor LIQ_MAN_ABR_228 May 2014 PN 51A-228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.rosemountanalytical.com CAUTION SENSOR/PROCESS
REGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G
Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G EN 215-1 HD 1215-2 Application RA 2910 built-in sensor RA 2920 tamperproof RA 5062 remote sensor temperature adjuster RA-FN
Elecraft K3 KPA3 Power Connector Replacement Revision A Review, April 16, 2012 Copyright 2012, Elecraft, Inc. All Rights Reserved
Introduction Elecraft K3 KPA3 Power Connector Replacement Revision A Review, April 16, 2012 Copyright 2012, Elecraft, Inc. All Rights Reserved The connectors furnishing high current to the KPA3 module
INSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:[email protected] www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
Installer s Guide 18-AH39D1-13
18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,
Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors
Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...
3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide
", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
E-PDD Duct Smoke Detector Installation Sheet
E-PDD Duct Smoke Installation Sheet Operation The duct smoke detector's primary purpose is to provide early warning of an impending fire and shut down the HVAC unit in order to prevent smoke from circulating
Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: The information included in this Splendide Repair Manual may change without notice. Please see our web site www.splendide.com/service/docs.html for updates,
Installation and Maintenance Instructions
Installation and Maintenance Instructions Limited One Year Warranty T&S warrants to the original purchaser (other than for purposes of resale) that such product is free from defects in material and workmanship
Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types
Installation Guide LR-HWLV-HVAC TouchPRO Wireless Touchscreen Thermostat System Types Gas, oil, or electric heat with air conditioning Warm air, hot water, high efficiency furnaces, heat pumps, steam,
G2 Optima Plus Flushometer
G2 Optima Plus Flushometer SENSOR MODULE COMPONENT PARTS 1 3 4 5 6 7 2 13 12 11 Item No. Code No. Part No. Description 1. 0325160 EBV-138-A G2 Cover/Ring/Sensor Assembly Water Closet 0325161 EBV-139-A
Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.
Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.
Instruction Manual EAGLE 500/550 EAGLE 700/750 EAGLE 900/950 EAGLE 1100/1150
Instruction Manual EAGLE 500/550 EAGLE 700/750 EAGLE 900/950 EAGLE 1100/1150 THANK YOU FOR CHOOSING RAIN BIRD We are aware that you have a choice, and we are happy you chose Rain Bird. The Eagle Rotor
Installation/ Operation Maintenance
Installation/ Operation aintenance VariTrane Pneumatic Controls arch 02 Thermostat Thermostat election and Location In general, both one- and two-pipe thermostats have a gain of 2.5 psi per degree Fahrenheit,
TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER
TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER 1. BEFORE YOU BEGIN A. HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials, and
Installing a Probe. Typical Installation
for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assembly
M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
430 Power/Electronics Replacement
Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed
SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT
REV. 05-04- SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT GENERAL Kit Numbers 95-08B, 9006-09B, 876-0A Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories
BULLETIN 70.00-1 OCTOBER 2012. DeZURIK ROTARY DIAPHRAGM ACTUATORS
BULLETIN 70.00-1 OCTOBER 2012 DeZURIK ROTARY DIAPHRAGM ACTUATORS 2 2012 DeZURIK, Inc. Design & Construction DeZURIK rotary diaphragm actuators are available for use on rotary control valves including:
PTU Series Ultrahigh-Purity Pressure Transducers
PTU Series UltrahighPurity Pressure Transducers User s Manual The Swagelok PTU series pressure transducer provides electronic monitoring of system pressure for ultrahighpurity applications. The PTU series
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems
APPLICATION AID SAA20 Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems Duct Air page 4 Thermal-Ribbon pages 6-7 Room Air Compact Room Air page
Product/Technical Bulletin
EP-8000 eries Electro-Pneumatic Transducers convert a voltage or current signal from an electronic controller into a pneumatic output pressure signal. An increase or decrease in the input signal proportionally
T-5800-1 and T-5800-2 Single Input Receiver-Controllers Installation and Calibration
T-5800-1 and T-5800-2 Single Input Receiver-Controllers Installation and Calibration 24-7028- 6, Rev. A Technical Bulletin T-5800-1/-2 Issue Date 0316 The T-5800 Series Receiver- Controllers are designed
2006 JUDY SERVICE GUIDE
2006 JUDY SERVICE GUIDE For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com. Information contained in this publication is subject
Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)
Service Manual Model No. PM5200 Series PM5300 Series (shown) SAVE THESE INSTRUCTIONS 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 www.precisionmedical.com
Step-by-step instructions:
Spark plug thread repair for Ford Triton cylinder heads Step-by-step instructions: Identification Installation Verification Specifically designed and tested for 4.6L, 5.4L, and 6.8L 2 and 4 valve heads,
ELECTRIC POSITION for electric heat, then confirm with Fan Test below.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
Hose Clamps & Fittings
All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw
Electronic Wallmount Faucet 1500T4 & 1501T4 Series
Electronic Wallmount Faucet 1500T4 & 1501T4 Series Specification: (example) Battery (4 C cell) or Hardwire (24 VAC) infrared electronic handwash system H 2OPTICS technology no external adjustments required
Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.
Worldwide Contacts www.tyco-fire.com Series Multiple Jet Controls DN20, DN25, DN40, and DN50, 2 bar BSPT Inlet & Outlets Threads General Description The TYCO Series Multiple Jet Controls are control valves
Watts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions