Engineering Guide and Valve Selection Information
|
|
|
- Jesse Cooper
- 9 years ago
- Views:
Transcription
1 Engineering Guide and Valve Selection Information
2 GC Valves Delivers Quality from the Inside Out We use only stainless steel hardware on our diaphragms. This includes the pilot orifice a wear point for many competitive designs. Our plungers are manufactured exclusively from 430FR stainless steel. Made only by a limited number of steel mills, 430FR is simply the best material available for solenoid operators. It combines excellent magnetic properties with a high degree of corrosion resistance. Our plunger tubes are all TIG welded for superior quality, instead of deep drawn. The result is a quieter valve due to better tube head alignment, and a stronger, longer lasting valve. Our tubes are designed to exceed a 6000 psi burst pressure. We believe in quality right down to our bolts and nuts. Most manufacturers save money on inexpensive hardware. We use stainless steel, because we believe our valves should resist corrosion outside as well as in. We are especially proud of our coil designs. Years ago we decided to end coil problems by standardizing on high temperature coil windings for all our coils. In addition, our standard coil is a NEMA 4/4X construction. GC Valves incorporates only proven time tested designs. The basic operators were designed by ITT General Controls and have been in continuous production for over 30 years. When combined with our commitment to the highest quality materials, these designs will yield years of trouble free operation. In fact, each operator is designed to operate trouble free for over 5,000,000 cycles. Index C v Factor...3, 7 Coil Enclosures...12 Cryogenics...10 Electrical Equipment Enclosures...6 Flow Charts...8, 9 Flow Media...3 General Purpose Solenoid Valves...4, 5 How To Select A Solenoid Valve...3 Industrial Solenoid Valve Applications...3 Material Selection Guide...11 Operating Pressure Differential...3 Power Requirements...3 Seal Materials & Shading Ring...7 Specific Gravity...10 Temperature...3 Vacuum...10 Valve Sizing...7 Viscosity...10 Voltage Changeover...6 Voltages West Coast Customer Service
3 Industrial Solenoid Valve Applications How To Select A Solenoid Valve We offer a wide variety of General Purpose Solenoid Valves from which to choose. To select the valve that best suits your application, determine the following: Valve Type and Operating Mode Available configurations include: 2-Way Normally Closed Two pipe connections (inlet and outlet) and one orifice to provide On-Off control. Valve is open when energized, closed when de-energized. 2-Way Normally Open Two pipe connections (inlet and outlet) and one orifice to provide On-Off control. Valve is closed when energized, open when de-energized. 3-Way Normally Closed Three pipe connections (one always open to one of the other two) and two orifices (one always open and one always closed) to regulate the direction of media flow. When energized, the flow is from the inlet port through the cylinder port; When deenergized, the flow is from the cylinder port through the exhaust port. 3-Way Normally Open Three pipe connections (one always open to one of the other two) and two orifices (one always open and one always closed) to regulate the direction of media flow. When de-energized, the flow is from the inlet port through the cylinder port. When energized, the flow is from the cylinder port through the exhaust port. 3-Way Universal, Diverting & Selecting Three pipe connections (one always open to one of the other two) and two orifices (one always open and one always closed) to regulate the direction of media flow. Valves can be installed to provide either normally closed (open when energized, closed when de-energized) or normally open (closed when energized, open when de-energized) operation. The valve can also be connected to select one of two flow media or to divert media flow from one port to another. Pipe Connections Pipe connections (ports) are openings which conduct the flow of the controlled media in and out of the valve. Factors influencing the selection of pipe sizes are the system s existing or designed pipe connection sizes and the flow requirements (Cv) of the application. C v Factor Cv is the amount of water at standard conditions (60 F, specific gravity = 1) in GPM (gallons per minute) which will pass through the valve with a one psi (pound per square inch) pressure drop across the valve in the full open position. The appropriate Cv will determine which combination of pipe and orifice sizes will be required for the application. Refer to the VALVE SIZING and Cv Factor pages for additional information. Maximum Operating Pressure Differential Maximum operating pressure differential is the maximum difference in pressure (measured in psi or bar) between the inlet and the outlet valve ports. Factors influencing the maximum operating pressure rating include the pipe connection sizes, orifice size(s), and design of construction. Operating Temperature Sealing materials, coil class, body materials, and duty cycle all influence the valve s temperature capabilities. Operating temperature is determined by a combination of media and ambient temperatures. Flow Media Flow media is the substance being controlled by the valve. The media s temperature, pressure, and concentration will determine the type of body and sealing materials required for the application. Consult the ENGINEERING INFORMATION section for data on flow media and valve materials compatibility. Power Requirements Voltage and Cycles (Hertz) will usually be determined by the system s existing power specifications. VA is a measure of the solenoid s power consumption. The inrush VA rating is the maximum initial surge of current required to energize the coil, while holding VA is a lesser current required to hold the valve in its energized position. In either case, the solenoid s amperage is determined by dividing the VA rating by the applied voltage. Inrush and holding currents are identical for DC solenoids, and the rating is given in watts (watts DC = volts x amperes). East Coast Customer Service
4 General Purpose Solenoid Valves Direct Acting S30 2- & 3-way 2400 psi C v to 1.7 Orifices to 3/8" Viton, EPR, Teflon, Rulon seals 1/8" to 3/8" S31 2- & 3-way 2400 psi C v to 1.7 Orifices to 3/8" Viton, EPR, Teflon, Rulon seals 1/8" to 3/8" S33 3-way, all ports in body 0 to 200 psi C v to.38 Orifices to 11/64" Viton, seals 1/8" & 1/4" Piloted Diaphragm S20 2-way Zero Differential; 3-way 200 psi C v to 23 Orifices to 1-1/4" Viton, EPR seals 3/8" to 1-1/2" S21 2-way 1 to 250 psi C v to 29 Orifices to 1-1/2" Viton, EPR, Teflon seals 3/8" to 2" S27 2-way Zero Differential 125 psi C v to 28 Orifices to 1-1/4" Viton, EPR seals 1" to 2" Piloted Piston Lever Acting Automotive S40 2-way 1200 psi C v to Orifices to 1-1/8" SS, Brass bodies Viton, Teflon seals 1/4" to 1-1/4" ports K13 3-way Fuel Oil Recirculating Valve 0 to 275 psi C v to 1.27 Orifices to 13/32" Brass body with metal seat 3/8" to 3/4" PV1C 2-way Fuel Valve 0 to 300 psi C v to 1.0 Orifices to 1/4" Die Cast Aluminum body with Nitrile seal 1/8", 1/4" Interface Assembies DIRECT OR MANIFOLD MOUNT 6.3 C v piloted diaphragm assembly for direct mount on OEM equipment 1" (inlet) x 3/4" NPT (outlets) manifold 3-way configurations available Brass or Stainless Steel Metering Manual Override DIN molded connector/cable DC Rectified coils Options Corrosion resistant coatings/seals Timers Stainless Steel trim DC Magnetic Latching operators Nickel Plating 4 West Coast Customer Service
5 Industrial Solenoid Valve Applications Air & Water Hot Water & Steam GENERAL PURPOSE 2- & 3-way 2400 psi C v to 2.9 Orifices to 1 1/2" Viton, EPR, Teflon, Rulon seals 1/8" to 2" HIGH TEMPERATURE 366º F Max. Fluid Temp. 2- & 3-way 0 to 2400 psi C v to 29 Orifices to 1-1/2" with EPR, Teflon, Rulon seals 1/8" to 2" Zero Differential Vacuum Cryogenic TO 2" NPT 2- & 3-way 2400 psi C v to 28 Orifices to 1-1/4" Viton, EPR, Teflon, Rulon seals 1/8" to 2" TO 10-6 TORR 2-way Brass & SS bodies Normally Closed & Normally Open 1/8" to 2" for Ultra-High Vacuum, contact GC Valves S30, S31 & S40 Specially coated plungers and tubes Exclusive reinforced seals Ultrasonically Cleaned Intended for liquid oxygen, liquid argon, liquid nitrogen Chemicals High Pressure Safety Shutoff INERT 2- & 3-way SS bodies with Nitrile, Viton, EPR, Teflon, Rulon seals 1/8" to 2"ports corrosion resistant coatings and seal materials available TO 2400 PSI 2-way Normally Closed to 2400 psi 2-way Normally Open to 1200 psi 3/8" Orifice Stainless steel body and seats 1/4", 3/8", 1/2" UL/FM/CSA 2-way, Normally Closed 0 to 300 psi 1/8" to 1/2"NPT Fuel Oil Natural Gas LP Gas Explosion Proof Manifolds/Assemblies NEMA 7 1/8"to 2" NPT available on most 2-way Normally Closed & Normally Open Designs 3-way Normally Closed, Normally Open & Universal Designs psi Direct Acting & Piloted designs 2- & 3-way; custom engineered Brass, SS, AL, Acetal bodies SPACE SAVER East Coast Customer Service
6 Electrical Equipment Enclosure Description The following information is transcribed from the requirements of NEMA and the American Institute of Electrical Engineers covering various classifications of the Underwriters Laboratories. These requirements are listed for reference purposes only. They are taken from the requirements of the approval associations or engineering groups. They are not necessarily an indication of what should be sold in the way of control apparatus. GC Valves does not supply all types of enclosures on all valves designs. (Contact GC Valves Customer Service for specific combinations.) NEMA Enclosure Types In non-hazardous locations, the specific enclosure types, their applications, and the environmental conditions they are designed to protect against, when completely and properly installed, are as follows: Type 1 - Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dirt. Type 4 - Enclosures constructed for either indoor or outsoor use to provide a degree of protection against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose-directed water; and that will be undamaged by the external formation of ice on the enclosure. Voltage Changeover S201, S202, S271, S272, S333, S334, S336 AC to AC; DC to DC Please note that unlike many of the older ITT designs, the valves listed above cannot be retrofitted from AC to DC or DC to AC by changing the coil. DC valves feature a chamfered interface between the plunger and plunger tube, while AC versions do not. AC and DC valves also have different spring configurations. S21 Standard designs can be converted from AC to AC and DC to DC voltages. They may not be changed from AC to DC or DC to AC voltages. High performance versions can be converted from AC to DC but not from DC to AC. S30, S31, and S40 AC to AC; AC to DC; DC to DC These ITT-designed valves can be converted from AC to AC, AC to DC, and DC to DC voltages. They may not be changed from DC to AC. Type 4X - Enclosures constructed for either indoor or outdoor use to provide a degree of protection against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed water, and corrosion; and that will be undamaged by the external formation of ice on the enclosure. Type 7 (C or D) Hazardous Locations Class I Air-Break (Specific to our rating) These enclosures are designed to meet the application requirements of the National Electrical Code for Class I, Hazardous Locations, which may be in effect from time to time. In this type of equipment, the circuit interruption occurs in air. Group C Atmospheres containing ethyl-ether vapors, ethylene, or cyclo-propane. Group D Atmospheres containing gasoline, hexane, naptha, benzine, butane, propane, alcohol, acetone, benzol, lacquer solvent vapors, or natural gas. GROUP E Atmospheres containing metal dust, including aluminum, magnesium and their commercial alloys, and other metals of similar hazardous characteristics. GROUP F Atmospheres containing carbon black, coal, or coke dust. GROUP G Atmospheres containing flour, starch, or grain dust. Notes: Changing voltages may change the maximum operating pressure may be reduced. Check catalog for applicable new operating pressure information or contact GC Valves Customer Service. Always insure that the correct temperature rated coil (Class F to Class F or Class H to Class H) is used when changing voltages. Changeovers should be restricted to those areas where you are aware of all the operating and electrical characteristics of the valve after the voltage change. If in doubt, contact GCV Customer Service. It should be noted that changing voltage by coil change in the field may make the valve pressure rating different from that printed on the nameplate. To assist in customer identification of voltage changes, contact GC Valves Customer Service for voltage stickers or new nameplates to indicate the new voltage and new operating parameters. K13 AC to AC; DC to DC K13 can be converted from AC to AC or DC to DC voltages only. They may not be changed from AC to DC or DC to AC. 6 West Coast Customer Service
7 Seal Material & Shading Ring Codes Position 9 Code Seal Shading Ring C EPR Copper E EPR Silver J Nitrile Silver K Teflon Silver K (S21) Viton Copper Code Seal Shading Ring L Viton Silver N Nitrile Copper R Rulon Silver S Teflon Copper T Teflon Copper Code Seal Shading Ring T (S21) Teflon/EPR Copper T (H40) Teflon/Viton Copper V Viton Copper Voltage Codes - Position 7 & 8 Code Voltage vac/60hz vac/60hz vac/60hz vac/60hz 220 vac/50hz vac/60hz 440 vac/50hz Code Voltage 14 6 vdc vdc vdc vdc vdc Code Voltage vac/50hz vdc vac/50hz vac/50hz vdc * For Additional Variations Contact GC Valves Customer Service. Valve Sizing & Cv Flow Factor Valve Sizing Procedures The successful operation of a controlled system depends on proper sizing of the valve. A practical method utilizing a graphical presentation of valve sizing based on the Cv ( C sub v ) ratings of valves is presented for the GC Valves general purpose designs. The Cv rating of any valve is the flow rate of water at standard conditions (60 F, specific gravity = 1) in GPM (gallons per minute), which will pass through the valve with a one psi (pound per square inch) pressure drop across the valve when in the full open position. This rating is determined by the manufacturer s tests and is published in catalogs and specification sheets. A valve so restricted or ported which passes 1 GPM of liquid with a specific gravity of 1 and an accompanying pressure drop of 1 psi is assigned a rating of Cv = 1. By comparison, a valve having a Cv = 2 would have twice the flow capacity with the same pressure drop. Please contact GC Valves Customer Service for assistance in determining the required flow factor for your application. Flow Charts The two charts, shown on the following pages, are presented to assist in the proper selection of valves. These charts provide a convenient and rapid means of solving fluid flow equations and are similar in nature, having a common basis. The two flow charts, one for liquids, the other for compressible fluids, are useful for valve sizing for normal applications. The use of the liquid flow chart is recommended for water and other liquids having relatively low viscosities. Liquids having high viscosities such as glycerine, Bunker C, and other heavy grade oils are not directly applicable to this chart. Valve selection for use with high viscosity fluids should be referred to GC Valves for recommendations. The flow chart for compressible fluids such as air and gases is also relatively accurate for the flow of saturated steam. Although the assumption for saturated steam flow is not strictly valid, the valves taken from this chart will be sufficiently accurate for most flow problems. Examples of typical problems of valve sizing are presented on the charts. Quite often in practice it is necessary to assume one or more properties of the fluid or the flow conditions. When arbitrarily assuming a factor affecting flow, it is advisable to determine and evaluate the effects of an error in the estimated value. In many cases an error in the data will not noticeably affect the proper valve sizing. East Coast Customer Service
8 Liquid Flow Chart Example 1 Determine the flow through a valve rated Cv=5 when passing water, specific gravity=1 with a pressure drop of P=10 psi. Solution: Enter chart at P=10 psi and read flow equal to 15.8 GPM. Example 2 What is the Cv rating of a calce which passes 60 GPM of water with a specific gravity of 1 with a pressure drop of P=100 psi? Solution: Enter a chart at pressure drop P=100 psi and also, at flow of 60 GPM and reads the Cv factor=6. Example 3 The valve in Example 2 is to be used in a service in which the liquid has a specific gravity of 1.5 and a flow of 24 GPM. Determine the pressure drop. Solution: Enter chart with a flow of 24 GPM and Cv=6 from above example and read pressure drop P=24 psi. Flow Chart Posters and Computerized Calculators are available from GC Valves Customer Service 8 West Coast Customer Service
9 Compressible Fluid Flow Chart Example 1 A valve with a flow factor rating Cv=2 discharging air at 600 F with an inlet pressure of 100 psig and a pressure drop of 10 psi. Determine the flow through the valve. Solution: Enter chart at a differential pressure?p=10 psi and real flow Q=48 C.F.M. Example 2 A valve having a flow factor rating Cv=1.2 discharging 1.9 C.F.M. of propane with a specific gravity of 1.54 and an inlet pressure of 0 psig. Determine the differential pressure in inches of water. Solution: Enter chart at a flow of 1.9 C.F.M. and read differential pressure?p=7 H 2 O. Example 3 A valve passing 1 C.F.M. of natural gas with a specific gravity of 0.7 having a differential pressure?p=0.5 H 2 O. Determine the Cv rating of the valve. Solution: Enter chart at differential pressure?p=0.5 H 2 O and at a flow of 1 C.F. M. and read rated Cv=1.6. Example 4 Determine the initial pressure required to have a flow of 90lb. per hour of saturated steam through a valve with a Cv rating of 0.45 and a pressure drop of 20 psi. Solution Enter chart at differential pressure?p=20 psi and at a flow of 90 lb. per hour and read inlet pressure 275 psig. East Coast Customer Service
10 Valve Characteristics Viscosity Specific Gravity Viscosity is the internal friction of a fluid tending to reduce flow. It varies greatly with temperature as well as from one fluid to another. The viscosity for liquids decreases with a rising temperature. The flow of a liquid such as water or gasoline having a low viscosity is not greatly affected by this internal friction. With liquids having high viscosities of 3000 SSU and above, such as glycerine, tar, and asphalt base crude oils, the effect of viscosity on flow is significant and should not be neglected. For applications of extremely viscous fluids, please contact GC Valves Customer Service. Specific Gravities of Common Gases and Liquids The specific gravity of fluid decreases with an increase in temperature. The effect of this change with respect to flow is negligible. For practical applications of Valve sizing, the average value of specific gravity for a fluid is sufficiently. Specific gravity varies greatly from one fluid to another, as indicated by the average values of specific gravities for the more common fluids listed below. Gases Specific Gravity Acetylene.897 Air Butane Carbon Dioxide Carbon Monoxide Chlorine Dimethylamine Ethane Ethylene Flourine Vacuum Applications Industrial vacuum also known as, low vacuum (760 Torr to 25 Torr) can be handled by many of the standard GC Valve designs. No special order codes are necessary, however so that appropriate records may be kept please contact GC Valves when a valve is intended for vacuum service. Standard valves suitable for use in industrial vacuum applications are: S201 S271 S30 (2 way) S401 Gases (Referenced to Air*) Gases Specific Gravity Helium Hydrogen Hydrogen Sulfide Illuminatating Gas Methane Methylamine Methyl Chloride Methyl Flouride Natural Gas Nitrogen.966 S202 S272 S31 (2 way) Cryogenic Applications Certain GC Valve designs can be modified for use in Cryogenic Applications. Typical applications include Liquid CO2 and Liquid Nitrogen. Please contact GC Valves Customer Service for additional information. Gases Specific Gravity Nitric Oxide Nitrous Oxide Oxygen Propane Sulphur Dioxide *Average weight pounds per cubic foot at standard air temperatures, 60º F and 14.7 psia pressure. (29.92 in Hg) Liquids Specific Gravity Acetic Acid 1.05 Acetone 0.79 Alcohol, commercial 0.83 Alcohol, ethyl 0.79 Alcohol, methyl 0.81 Chlorine 0.66 Dimethylamine 1.27 Brine Ethylene 1.23 Flourine 1.19 Bromine 2.97 Carbolic Acid 0.96 Carbonic Acid 0.92 Carbon Disulfide 1.26 Carbon Tetrachloride 1.59 Chlorine 1.56 Liquids (Referenced to Water**) Liquids Specific Gravity Ether 0.73 Ethyl Acetate 0.90 Fuel Oil 0.82 Gasoline 0.72 Glycerine 1.26 Hydrochloric Acid Concentrated 1.19 Hydroflouric Acid Concentrated 0.99 Kerosene 0.81 Linseed Oil 0.94 Milk 1.03 Mineral Oil 0.92 Muriatic Acid 1.20 Naphtha 0.77 Nitric Acid 1.50 Liquids Specific Gravity Oelic Acid 0.90 Ethyl Acetate 0.82 Phosphoric Acid 1.75 Sulfuric Acid 1.83 Tar 1.00 Turpentine Oil 0.87 Vinegar 1.07 Water 1.00 Water, Sea 1.02 **Average weight 62.4 pounds per cubic foot at ordinary air temperatures, 60º F. 10 West Coast Customer Service
11 Material Selection Guide for Corrosive Media S Satisfactory F Fair T Test (May or may not be used) U Unsatisfactory CAUTION: This material selection guide must be treated as a guide only. There are a number of factors such as temperatures, pressure, and concentration of solution that can change a Satisfactory (S) rating into a Fair (F) or Unsatisfactory (U) rating. For specific materials recommendation on your application, contact GC Valves Customer Service. Be prepared to provide a complete description including media, temperature, pressures, and flow rates required. East Coast Customer Service
12 Standard Enclosures Housing Codes - Position 5 Conduit Coil Family S3 & S4 G A W NEMA 4/4X; Fully encapsulated, 24 inch lead wires, 1/2" conduit hub DIN Coil Family S3 & S4 Y NEMA 1; Metallic housing, 24 inch lead wires, 1/2" conduit hub DIN OPTIONS NEMA 4; Metallic housing, 24 inch lead wires, 1/2" conduit hub Grommet Coil Family S3 & S4 B ISO; Fully encapsulated, spade terminal, European configuration, NEMA 4 ISO; Molded connectors, cables, timers etc. designed for DIN coil/housing Metallic housing, 24 inch lead wires Junction Box Coil Family S3 & S4 S U Open Frame Coil Family S3 & S4 P Standard with 1/2" conduit knockout, lead wires NEMA 7 Coil Family S3 & S4 Compact with two 1/2" conduit knockouts, lead wires Junction Box Coil Family S5 24 inch Lead Wires Conduit Coil Family S5 X Contact GC Valves Customer Service for dimensions. U A Explosion Proof; 24 inch lead wires, 1/2" conduit hub Class I & II Groups C, D, E, F & G, Division 1 & 2 Compact with two 1/2" conduit knockouts, lead wires NEMA 1; Metallic housing, 24 inch lead wires, 1/2" conduit hub 12 West Coast Customer Service
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
NEMA Enclosure Types
The purpose of this document is to provide general information on the definitions of NEMA Enclosure Types to architects, engineers, installers, inspectors and other interested parties. [For more detailed
% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
WELCOME TO MAGNATROL
Catalog 6 BULLETIN 6-INDEX WELCOME TO MAGNATROL Process Control Solenoid Valves For Water Oil Air Gas Steam Cryogenics Vacuum Solvents Brine Oxygen Corrosive Fluids Magnatrol Valve Corp. Established 1936
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
Four-Way Valves. Accessories TABLE OF. Rotary and Smart. Actuator Motors
TABLE OF CONTENTS 389 We stock more than 2,000 different ASCO solenoid valves, repair kits, and replacement coils. What we don t stock, we can usually get from the factory within 5 working days! As the
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
Coil Classification: Class F standard, Class H available Class B standard on V9xx models
Direct Acting & Pilot Operated Valves 1/8" - 1/2" General Description: Direct Acting and Pilot Operated valves are used in applications for actuation of double acting cylinders and piloting of larger control
AUTOMATIC CHANGEOVER MANIFOLD Series 915
AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm
Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
VSO MAX HP High Flow Proportional Valve
VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters M-4270/0707, pg. 2 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY
4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems
Dynamic Solutions Leadership and Innovation in Valve Products and Valve Systems At ASCO, Valve Performance Begins and Ends With People 4 First of all, it begins with the people we serve. It is from them
Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
Precision Solenoid Valves
Precision Solenoid Valves Solenoid Valves for gas General Purpose Valves Specialty Solenoid Valves n Didn t see what you re looking for? Let us review your requirements and chances are we can help solve
Air Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
Solenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
SQUARE D INDUSTRIAL CONTROL PRODUCTS
SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
IP Rating Chart. 910 East Orangefair Lane Anaheim, CA 92801 USA. www.anaheimautomation.com 714-992-6990 714-992-0471, Fax
IP, NEMA and UL Rating Codes The International Protection Rating, sometimes referred to as an Ingress Protection rating, is a set of codes used to define specific levels of protection. These codes consist
Morrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
Explosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection. www.swagelok.com
www.swagelok.com Valve Sizing Te chnic al Bulletin Scope Valve size often is described by the nominal size of the end connections, but a more important measure is the flow that the valve can provide. And
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
Solenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid
2- and 3-way Solenoid Valves for Gas and Liquid SV10: Vacuum to 3000 psig SV430: Vacuum to 3000 psig SV20: Vacuum to 6000 psig SV460: Vacuum to 6000 psig SV30: Vacuum to 3000 psig Circle Seal Controls
Fire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
Regulator Options and Accessories
Regulator Options and Accessories Regulator accessories are available separately or mounted on Swagelok regulators. Some accessories limit regulator pressure or temperature ratings. Additional materials,
HOW TO SIZE A PRESSURE REGULATOR
CHOOSING THE CORRECT REGULATOR HOW TO SIZE A PRESSURE REGULATOR In order to choose the correct regulator the following information is needed: - Function: Pressure reducing or backpressure control? - Pressure:
Intrinsically Safe Barrier Relays NY2 and 8501TO
Intrinsically Safe Barrier Relays NY2 and 8501TO Class/File 8501 CONTENTS Description.....................................................Page NY2 General Information..............................................
Vacuum and Compressor Systems for the Chemical Process Industry
Vacuum and Compressor Systems for the Chemical Process Industry Vacuum Pumps & Compressors Proven technology built from experience Gardner Denver Nash has been serving process industries such as petroleum,
STC 3S012-020-A Series Solenoid Valves
STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,
Chapter 5 - Aircraft Welding
Chapter 5 - Aircraft Welding Chapter 5 Section A Study Aid Questions Fill in the Blanks 1. There are 3 types of welding:, and, welding. 2. The oxy acetylene flame, with a temperature of Fahrenheit is produced
289 Series Spring-Loaded Relief Valves
October 14 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L and 89U Relief Valves Introduction The
REGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
Fluid & Gas Properties
Fluid & Gas Properties FLUID DENSITY Density is the ratio of mass to volume. In English, units density is expressed in pounds mass/cubic foot (lbm/ft 3 ). The symbol for density is ρ. Density is usually
Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:
Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees
ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
AIR LINE VALVES AND GAUGES
AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand
Screw Plug Immersion Heaters
Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters
Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15
The Connection Bulletin for Forged Steel Flow Control Valves CB 15 Flow Control Division Forged Steel Flow Control Valves GRADUATED DIAL AND INDICATOR FULLY GUIDED V-PORT THROTTLING DISC AND INTEGRAL HARD
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Types 66R and 66RR Low-Pressure Relief Valves
November 2009 Types 66R and 66RR Low-Pressure Relief Valves W1953 W1908 TYPE 66R RELIEF VALVE TYPE 66RR RELIEF VALVE Figure 1. Typical Constructions Introduction Types 66R and 66RR low-pressure throttling
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
SOLENOID VALVES AND PNEUMATIC VALVES
2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the
STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting
STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8
TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation
GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation
Frequently Asked Questions Generators
Frequently Asked Questions Generators Fuel Related How much fuel do the generators use during normal operation? At exercise? The generator fuel consumption is given in each of the product knowledge books
Solenoid Valves and Their Importance in Refrigeration Systems. October 2007
Solenoid Valves and Their Importance in Refrigeration Systems October 2007 Overview Introduction Solenoid valves play an important role within refrigeration and air conditioning systems, controlling the
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
NORMAN FILTER COMPANY PRODUCT OVERVIEW
NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100
Compliant Healthcare Technologies, LLC. NFPA 99, 2012 Changes" November 13, 2013!
Compliant Healthcare Technologies, LLC NFPA 99, 2012 Changes November 13, 2013! The standard is now a CODE!! The NFPA 99 has now been upgraded from a Standard to a Code. This will put it in the same light
Excellence through Versatility
Metering Pumps Excellence through Versatility Liquid Metronics Incorporated has been providing quality products and service to the water treatment industry worldwide for over 25 years. Leading the way
Pressure and Temperature Controls
Pressure and Controls Pressure Reducing Armstrong pressure reducing valves (PRVs) and temperature regulators help you manage steam, air and liquid systems safely and efficiently. And assure uninterrupted
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
3 Port Solenoid Valve
ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
API Flanged Safety Relief Valves Series 526 CATALOG
API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes
North American Stainless
North American Stainless Flat Products Stainless Steel Grade Sheet 310S (S31008)/ EN 1.4845 Introduction: SS310 is a highly alloyed austenitic stainless steel designed for elevated-temperature service.
RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007
Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid
Basics of Explosion Protection
Basics of Explosion Protection INTRODUCTION Understanding Global Explosion Protection Class and Division System Class-Zone System CENELEC Zone System IEC A INTRODUCTION Basics of Explosion Protection Basics
Application Feature Valve Nominal Liquid Capacity R-22 (in tons)*
EMERSON CLIMATE TECHNOLOGIES-Solenoid Valves & Coils Quick Select Guide Applications Application Feature Valve Nominal Liquid Capacity R-22 (in tons)* Nominal Liquid Capacity R-410A (in tons)* Liquid Line
SAFETY BLOCK type BS 9.3 E 01-12
SAFETY BLOCK type BS 9.3 E 01-12 9.3.1 TECHNICAL DATA MAX OPERATING PRESSURE (PS): 420 bar PRESSURE TEST (PT): 1.43 x PS NOMINAL PASSAGE DIAMETER: 10mm, 20mm, 25mm, 32mm WORKING TEMPERATURE: -40 +150 FLUID
3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
SafeSite LED RTO Area Light - UL844. for Indoor and Outdoor Industrial Applications #
SafeSite LED RTO Area Light - UL844 for Indoor and Outdoor Industrial Applications # On when it matters most. Products and solutions that protect your business 2 www.dialight.com MDTFSSWRTOX001_J Features
BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features
Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive
Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.
Steam Tables What They Are How to Use Them The heat quantities and temperature/ pressure relationships referred to in this Handbook are taken from the Properties of Saturated Steam table. Definitions of
3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER
BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER Valve size often is described by the nominal size of the end connections but a more important measure is the flow that
BERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features
High Pressure, Surge Anticipating Control Valve Eliminates surge in all pumping systems: Booster & deep well, single & variable speed Eliminates surge in all distribution networks: Municipal, high-rise
OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.
Our Other Products OUR PRODUCTS Liquid Ring & Rotary Vane Vacuum Pumps and Systems Liquid Ring Vacuum Pumps: 3 CFM to,000 CFM Liquid Ring Compressors up to 1 psig Heat Transfer Pumps for hot thermal oils
TYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
Technical Information
Determining Energy Requirements - & Gas Heating & Gas Heating and gas heating applications can be divided into two conditions, air or gas at normal atmospheric pressure and air or gas under low to high
Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.
DAN-LIQ-TG-44-rev0208 February 2008 Daniel Liquid Control Valves Technical Guide www.daniel.com Daniel Measurement and Control Theory, Principle of Operation and Applications This brochure has been prepared
Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409
Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Solenoid and Air Operated Valves. Supporting Fleet Operations for Over 60 Years
4 Solenoid and Air Operated Valves Supporting Fleet Operations for Over 60 Years This catalog describes solenoid and air operated valves, representative of those manufactured by ASCO Valve, Inc. to meet
IOM SERIES 820-E/P Electro-Pneumatic Positioner
FLUID CONTROL DIVISION Parker Hannifin Corporation 95 Edgewood Avenue New Britain, CT 06051 Telephone (860) 827-2300 IOM SERIES 820-E/P Electro-Pneumatic Positioner INSTALLATION, OPERATING & MAINTENANCE
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial
sect. 05 9600 rev. 206/08/0 Pressure Gage and Swichgage Instruments OPL Series 4-/2 in. (4mm) Diameter Dial The OPL-series pressure Swichgage instruments are combination pressure indicating gages with
400B SERIES DIAPHRAGM PUMP
400B SERIES DIAPHRAGM PUMP In today s agricultural and industrial markets, isn t it good to know that you can rely on one name Sotera to fit your chemical transfer needs? The Sotera 400B Series offers
Pumping Fuel & Fuel Oil
Pumping Fuel & Fuel Oil Fuels & Rotary Pumps Though the handling of fuel oil is not necessarily "challenging," the reliable handling of fuel oils is critical for heating and transportation systems. Rotary
Thermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm
167D Series Switching Valves
June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification