IntesisBox KNX Modbus RTU master



Similar documents
IntesisBox KNX Modbus TCP master

IntesisBox KNX - LON

KNX Panasonic Air Conditioners

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

IntesisBox Modbus Server Fidelio IP

IntesisBox KNX LG Air Conditioning

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox KNX Mitsubishi Heavy Industries AC

Modbus Server SAMSUNG Air Conditioners

IntesisBox ASCII Server - LON

IntesisBox Modbus Server - Mitsubishi Electric G50

Inwall Room Temperature Unit

User manual Compact Web PLC WP240 series IEC-line

Electronic Control Devices The European Product Catalogue 2007

IntesisBox. Making Building Automation go further. KNX EIB Products

TX OPEN RS232/485 module

Electronic Control Devices The European Product Catalogue 2007

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

PCS0100en Persy Control Services B.V. Netherlands

Rack mounted telephone- and leased line modem for industrial applications

EDI Distributor Control Interface Wiring and Setup Instructions

Modbus Communications for PanelView Terminals

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Inwall 4 Input / 4 Output Module

KNX Interface. User Manual PM00A00IRI

Telephone- and leased line modem for industrial applications TD-36

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

IntesisBox DK-RC-ENO-1iC. EnOcean Interface for DAIKIN Air Conditioners Compatible with SKY and VRV lines

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

Process Control and Automation using Modbus Protocol

Product and functional description

Application/Connection Examples

OZS Web server. For LPB/BSB plants

How To Use A Power Supply On A Powerline 2.2 (Ai)

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

QSE-CI-NWK-E Control Interface

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Waveguide Access Point WGA631. Product Guide

FX07 Field Controller

TX2123 RS485 TO ETHERNET ADAPTOR

Bluetooth HC-06 with serial port module Easy guide

Digital input modules

ELCOMPONENT LTD. User Manual

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Communication standards and Carel solutions

NetBiter webscada Modbus User Manual

Unidirectional Transmitter/ Receiver Units Introduction

Optimize your simple machines... Modicon M218 Selection Guide

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

connecdim Gateway G1 Ethernet TCP/IP to DALI

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

OZW V2.0. Web server. Synco TM, Synco TM living

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

TAC I/NETTM MR-AHU-HP. Application Specific Controller

Modbus RTU (RS-485) TCP/IP (Ethernet)

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

MODBUS TCP to RTU/ASCII Gateway. User s Manual

HARTING econ 3000 Introduction and features

1 Serial RS232 to Ethernet Adapter Installation Guide

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

One Port Serial Server Users Manual Model ESP901, ESP901E

ABB i-bus KNX Fan Coil Controller FC/S 1.1

NX safety stand-alone

Using HyperTerminal with Agilent General Purpose Instruments

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

IntesisBox. Making Building Automation go further. Modbus Products

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

HARTING mcon 1000 Introduction and features

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

ewon COSY 141 Installation Guide

Modbus and ION Technology

PNSPO! Modbus Solution CP1H / CP1L / CJ1 / CJ2 / CS1. Version /18/2009

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

Remote Monitoring and REC 501 Control Unit Product Guide

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4

User Manual Revision English

Functions module / Gateways. KNX-GW-RS232-RS485 Product Group 1

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Niko Home Control. Installation Manual

Application Note. Positioning with Dimetix distance sensor and SEW inverter FLS-C

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

Transcription:

IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control systems. KNX EIB Bus IntesisBox RS485 (can be also RS232 for single connection) RTU LinkBoxEIB Configuration Software RS232 Only needed for configuration IntesisBox acts as a RTU master device in its interface, reading/writing points of the device(s), and offering this point's values through its KNX interface. IntesisBox acts in the KNX side as one more device of the KNX system. IntesisBox's KNX EIB interface connects directly to the EIB bus and is opto-isolated from the rest of the internal electronics The interface of IntesisBox reads continuously by polling the devices/registers configured. If a non response of the is detected, the corresponding virtual signal inside IntesisBox will be activated indicating communication error with the device. All the updated readings of the registers are maintained in IntesisBox memory for immediate interaction with KNX when needed. Each register of the device is associated to a KNX group address. All the registers of the different s are accessible through KNX group addresses. When a change in any register/ occurs, a write egram is sent to the KNX bus, to the associated KNX group address. This is configurable individually per point. IntesisBox KNX series are configured using LinkBoxEIB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. With the standard installation of LinkBoxEIB, a Demo project for integration of devices is also installed, using this demo project makes the engineering needed for this integration easy and quick. 1 / 9

IntesisBox capacity Element 100 version Type of devices A version B version Notes Those supporting RTU protocol. Communication over RS485 network (2-Wire) or RS232 point to point. Points 100 500 3000 Maximum number of points that can be defined into IntesisBox. devices 254 254 254 Maximum number of devices allowed by IntesisBox. Virtual signals 1 per device 1 per device 1 per device 1 communication error signal per device defined. All available from KNX. There are three different versions of IntesisBox - KNX RTU master with different capacity every one of them: Version with capacity of 100 points and up to 254 devices. Ref. IBOX-KNX-MBRTU-100. Version with capacity of 500 points and up to 254 devices. Ref. IBOX-KNX-MBRTU-A. Version with capacity of 3000 points and up to 254 devices. Ref. IBOX-KNX-MBRTU-B. 2 / 9

Sample applications Integration of any RTU device into KNX control systems. KNX EIB Bus IntesisBox RS485 (can be also RS232 for single connection) RTU KNX control system: Typical devices: Building Automation. Home Automation. Chillers. Heaters. Air conditioners. Thermostats. Fan coil controllers. Room controllers. Power meters. Energy meters. Building Management Systems (BMS). Programmable Logic Controllers (PLC). Other protocol based systems available using IntesisBox Server series gateways.... KNX Full monitoring and control s System monitoring / controlling System under monitoring / control 3 / 9

Typical application Integration of Electricity Meters with RTU port on RS485 into KNX control systems. KNX / EIB IntesisBox KNX - RTU master RTU (RS485) 4 / 9

KNX interface of IntesisBox KNX/EIB interface Bus coupler Configuration parameters Interactivity with KNX/EIB system Points Configuration parameters per point Internal KNX TP1 (EIB) opto-isolated bus coupler unit for direct connection to EIB bus. Connector: 2 poles plug-in screw terminal block. Physical address. The points can be read from KNX. Configurable individually per point. The points can be written from KNX. Configurable individually per point. A write request can be sent to KNX following a change in the point s value. Configurable individually per point. The point value can be updated with a read request sent to KNX when IntesisBox starts up or after a bus reset detection. Configurable individually per point. Multiple KNX group addresses can actuate on the same IntesisBox s point. Generic fields. Point description. Useful to identify the point s location into the system. Active (Yes/No). Useful to deactivate points maintaining the configuration for later use. KNX/EIB related fields. Group address (in format P/I/S or P/S). Is the sending group address. Listening addresses (in format P/I/S or P/S separated by comma). The gateway will listen for write requests for these listening addresses, when received then it will act as if they where for the main group address defined. This is very useful to translate actions to the system coming from different KNX commands, for example from an individual start/stop button and also from a general start/stop button. Up to 1000 listening addresses can be defined in total. Up to 255 listening addresses can be defined per point. R. Specifies if the point accepts read requests from KNX. W. Specifies if the point accepts write requests from KNX. T. Specifies if a write request will be sent to KNX when the point s value changes. U. Specifies if the point s value must be updated with a read request sent to KNX when the gateway starts up or after a bus reset detection. If U is specified in this field, the read request will be of the main group address. If U2 is specified in this field, the read request will be of the first listening address defined. EIS (Datapoint). See EIS supported below. The configuration of this part must be done in co-operation with the engineer in charge of setting up the whole KNX system. Some of the data to introduce in this part must be supplied by the KNX engineer. KNX EIS (Datapoints) supported Switching (1 bit). Dimming (4 bits). Float (16 bits). Scaling (8 bits). Drive control (1 bit). Priority (2 bits). Float IEEE (32 bits). Counter (8 bits). Counter (16 bits). Counter (32 bits). ASCII char (8 bits). 5 / 9

interface of IntesisBox interface Device type modes supported RTU configuration parameters Interactivity with system Points Configuration parameters per point function codes supported data coding formats supported Master. RTU RS232 or RS485. RS232 or RS485. Baud rate. Data bits. Parity. Slave number per each device defined. Read: Continuous polling of devices and points defined. Updated values are available from KNX. Polling Timeout and Inter-frame Timeout can be configured in the interface. Write: Whenever a point s value is changed from KNX, the new value received is written into the device/register related. related fields. Device number (from the predefined devices list). register address into the device. Bit inside the register (optional). IntesisBox allows bit decoding from generic 16 bits input/holding registers. Bit coding into 16 bit input/holding registers is used for some devices to encode digital values into this type of registers, being these registers accessible using function codes 3 and 4 (read holding/input registers). function code. See function codes supported below. data coding format. See data coding formats supported below. This information must be extracted from the technical documentation of the devices to use. For each point, one of the following function codes can be used: 1- Read coils. 2- Read discrete inputs. 3- Read holding registers. 4- Read input registers. 5- Write single coil. 6- Write single register. 15- Write multiple coils. 16- Write multiple registers. For each point, one of the following data coding formats can be used: 1 bit. 16 bits unsigned. 16 bits signed. 16 bits signed (two s complement). 32 bits unsigned. 32 bits signed. 32 bits signed (two s complement). 32 bits IEEE. 32 bits IEEE inverted. Bit coded into 16 bits register. And many more which are device specific. 6 / 9

Configuration tool LinkBoxEIB Visual engineering tool, easy of use, for IntesisBox s configuration and monitoring compatible with Microsoft Windows operating systems, supplied with the purchase of IntesisBox with no additional cost. Multi-window tool allowing to monitor simultaneously the communication activity with both protocols (systems) and the real time values for all the points allowing to modify any value (very useful for test purposes), console window showing debug and operation status messages, and configuration windows to configure all the IntesisBox s parameters and points. Points configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points). Allows configuring the IntesisBox s parameters and points while in off-line, this is, not connected to the gateway. You can configure/modify the IntesisBox's parameters comfortably in the office and later download the configuration to the IntesisBox in the field. Connection to the IntesisBox for download the configuration and monitoring by using a serial COM port of the PC (serial cable also supplied). Allows configuring all the external protocols available for IntesisBox KNX series. Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox KNX series. Multi-project tool allowing to have in the engineer s PC the configuration for all the sites where different IntesisBox KNX series gateways have been installed. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. A list of system commands is available to send to the IntesisBox, for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request ). 7 / 9

Mechanical & Electrical characteristics Enclosure Plastic, type PC (UL 94 V-0). Dimensions: 107mm x 105mm x 58mm. Colour Light Grey. RAL 7035. Power Terminal wiring (for power supply and low-voltage signals) Mounting RTU ports KNX port LED indicators 9 to 30Vdc +/-10%, Max.: 125mA. 24Vac +/-10% 50-60Hz, Max.: 127mA Must use a NEC Class 2 or Limited Power Source (LPS) and SELV rated power supply. Plug-in terminal block for power connection (2 poles). Per terminal: solid wires or stranded wires (twisted or with ferrule) 1 core: 0.5mm 2 2.5mm 2 2 cores: 0.5mm 2 1.5mm 2 3 cores: not permitted Wall. DIN rail EN60715 TH35. 1 x EIA485. Plug-in screw terminal block (2 poles). SELV 1 x EIA232. DB9 male connector (DTE). SELV 1 x KNX TP1 (EIB) port opto-isolated. Plug-in terminal bloc (2 poles). TNV-1 1 x Power. 2 x KNX port activity (Tx, Rx). 2 x RTU port activity (Tx, Rx). 1 x KNX programming/bus. 1 Push buttons 1 x KNX programming. 1 Console port EIA232. DB9 female connector (DCE). SELV Configuration Via console port. 2 Firmware Allows upgrades via console port. Operational temperature -40 C to +70 C Operational humidity 5% to 95%, non condensing Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). Norms and standards CE conformity to EMC directive (2004/108/EC) and Low-voltage directive (2006/95/EC) EN 61000-6-2 EN 61000-6-3 EN 60950-1 EN 50491-3 1 2 Not operational for the moment. Reserved for future use. Standard cable DB9male-DB9female 1,8 meters long is supplied with the device for connection to a PC COM port for configuring and monitoring the device. The configuration software, compatible with Windows operating systems, is also supplied. 8 / 9

Dimensions Power RS232/RS485 KNX port 58 mm Console port 107 mm 105 mm Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections: 100 mm 115 mm 130 mm 9 / 9