OZS Web server. For LPB/BSB plants
|
|
- Roger Byrd
- 8 years ago
- Views:
Transcription
1 s Web server For LPB/BSB plants OZS Remotely operate and monitor a LPB or BSB device Web browser operation via PC/laptop or Smartphone SMS operation via mobile phone (OZS164.23) 2 digital inputs for fault messages Send fault messages as or SMS (OZS164.23) Connections: USB (commissioning), Ethernet (local/remote), GSM (OZS164.23) Software update CE1Q5711en Building Technologies
2 Use Buildings Owners/operators Single and multi-family homes Commercial and small industrial buildings Home owners Real estate agencies, real estate management companies. HVAC and electrical engineers Service organizations Heating system manufacturers (e.g. field tests) Functions Operation Web browser and SMS operation Attractive, clear web browser user interface Simultaneous support of multiple users Definable user profiles Faults / System report Fault sources Send faults and system reports to max 4 different and SMS recipients Directly send SMS to mobile phone (OZS only) Each recipient has a "scheduler with calendar" to program three sending times per day and holidays/special days The web server is able to identify faults and failures of the bus device as well as own faults. Fault indication The web server indicates bus device and web server faults via LED lit for as long as the fault is present.. The LED is System messages Connection test The web server generates system reports and periodically sends the system operating state to different recipients. Messages are sent as per the set time (hh:mm), message cycle interval ( days), and priority (urgent/non-urgent) to message recipients. When triggered via remote button, the web server sends a system report to all message recipients regardless of its own fault priority. Message history The message history includes the last 500 events on faults, fault messages, and system reports. The events are entered in the web server's circular message buffer. Message history data can be read via web browser. Time The web server has a system clock with adjustable daylight saving/standard time changeover. Clock time mode can be configured autonomous, or as either master or slave. Type summary Device Ethernet web server Ethernet web server and GSM Type (ASN) OZS164.13/101 OZS164.23/101 2 / 12
3 Ordering and delivery Please indicate the type (ASN) when ordering. Components: The web server is delivered in a cardboard box. The installation instructions G5711 are inserted in the package. The commissioning instructions C5711 (de / en) are available on the web server at address>/doc/. Additional accessories: Power supply unit, Ethernet cable, USB cable, 2 cable ties. Equipment combinations LPB/BSB devices Notes An LPB or BSB device can be connected to the LPB/BSB interface of the central communications unit. The following devices with LPB or BSB connection are supported: Heating controllers RVA, RVS Boiler management units LMU Contact us for detailed compatibility list of LPB/BSB devices. SMS operation is not supported by all devices. Web browser PC/Laptop (1024 x 786) iphone (480 x 320) Internet Explorer V6.0 or higher Firefox V3.0 or higher Safari Number of browsers Any number of browsers can be used simultaneously. The max. data traffic on the line is divided up among the browsers. As a result, operation slows down depending on the number of simultaneous users. GSM (OZS164.23) SIM card GSM antenna Mobile phones allow for operation and monitoring via SMS. A standard SIM card can be used for the web server. A remote, suitable GSM band antenna with SMA plug (male) can be used in lieu of the delivered antenna, e.g. ANT-GXS6624 by Round Solutions. Product documentation Web server OZS164 Document type Installation instructions Commissioning instructions CE Declaration of conformity Document number G5711 C5711 T / 12
4 Technical design Operation, monitoring, alarming Communication connections for local commissioning (USB), remote operation, remote monitoring and alarming via Ethernet or GSM (OZS only): Internet 5711Z01 Router heilibe droszdlockner mitte führe iblade un USB Ethernet * GSM * OZS164.. LPB/BSB Antenna and GSM network: OZS only Interfaces Cable/plug types USB Ethernet LPB/BSB Protocols Web operation Fault messages Digital inputs The web server has 3 interfaces for communication between web server and user: USB, Ethernet, GSM (OZS only). The LPB/BSB connection is used to connect the bus device. The USB interface directly connects the PC/laptop on site. The required USB cable type A / type Mini-B is delivered with the device. The router/network is connected to the Ethernet RJ45 plug. The Ethernet interface features Auto-MDI(X) for crossed and non-crossed Ethernet cables. A Ethernet cable category 5 is delivered. The bus device is connected to terminals DB/CL+ and MB/CL- designated "A " (see "Mechanical design"). Use HTTP (Port 80) via TCP / IP for web operation. A RNDIS driver on the PC is required for USB communication. The RNDIS driver is installed automatically when the PC is connected to the Internet. The driver is stored on the web server under address>/drivers/. Fault messages via use SMTP. Fault messages are sent as SMS via GSM (OZS only). The digital inputs D1, D2 help connect potential-free status contacts. They work as fault inputs. 4 / 12
5 Mechanical design Design The web server consists of the housing lower section with printed circuit boards and interfaces as well as connection terminals. The upper housing section contains the printed circuit boards. The upper housing section contains the LED displays and one operating button. The LEDs and operating button are labeled. A removable cover provides access to the terminal area. This area contains the connection terminals, one additional button, one LED, one double DIP switch, and a SIM card slot (OZS only) * A A 1 D1 2 M C 3 D2 4 M B B * Pos. Name Element 1 On-LED LED (green / red) 2 LPB/BSB LED A LED (green) 3 (LED) B LED (no function) 4 Fault LED LED (red) 5 (LED) LED (no function) 6 Remote button Button 7 Service button Button 8 DIP switch message suppression Switch 9 (Switch) Switch (no function) 10 Terminals Connection terminals LPB/BSB (left) A Terminals Connection terminals digital inputs (center) C Terminals (Connection terminals) (right) B Terminals (no function) 11 External voltage plug DC connection 12 USB plug USB connection Mini-B 13 Ethernet plug RJ45 network connection 14* GSM antenna Rod antenna 15* SIM card slot Card slot * OZS only 5 / 12
6 Notes Mounting You can mount the web server in a panel, a distribution box, or on flat wall. Plan sufficient space around the unit for easy wiring. Make sure service can easily access the unit and the unit is ventilated properly. Vertical mounting (circulation via vent holes) is required at ambient temperatures greater than 35 C. Standard mounting On standard rail TH Wall mounting Screwed to wall Mounting position Horizontal or vertical Mounting and dimensions See "Dimensions" Installation Important Operating voltage Wiring Connection terminals Commissioning Connections Router IP address Observe the following when installing: Run fuses, switches and wiring as per local regulations for electrical installations. We do not recommend plant monitoring via USB interface in environments with strong electromagnetic interference (e.g. in industrial environments with electrical welding equipment). See "Technical data" for electromagnetic compatibility. The delivered power supply unit supplies the required 24 VDC operating voltage for the web server. The terminals for the LPB/BSB bus as well as the digital inputs are located at the bottom of the device. The operating voltage plug 24 VDC as well as the plugs for USB, Ethernet, and GSM (OZS only) interfaces are located on top of the device. The terminals are designed for mm 2 solid wire cross-sections, or mm 2 stranded wire cross-sections. Commission the web server locally via USB interface using the PC or laptop. The PC/laptop must contain a suitable web browser (see "Equipment combinations"). You need a USB cable type A / type Mini-B to locally connect the USB interface of the web server to the PC laptop. See the installation instructions G5711 (attached) or commissioning instructions C5711 (saved on web server at address>/doc/ ) for more information. You need a suitable router for remote operation via Internet. The router must support NAT/PAT as well as DynDNS for dynamic IP addressing. The IP address via USB is canned: Default setting for IP address via Ethernet: Users must manually set the IP address as per their home network. 6 / 12
7 User groups User accounts are created and assigned to specific user groups for customized user operation. End user Service Administrator Works with end user data, fault overview, and manages own user account. Works with data at Service and End user levels, fault overview, message history, logos, documents, system definitions, and manages own user account. Works with data at Service and End user levels, fault overview, message history, logs, documents, system definitions, creates device web pages, and manages all user accounts. Maintenance The OZW164 web server is maintenance free (no battery changes, no fuses). Clean the housing only with a dry towel. Repair The OZS164 cannot be repaired on site. If faulty, return to the Repair Center of the relevant Regional Company. Disposal Dispose of the device as electronic waste in compliance with European directive 2002/96/EEC (WEEE) and not as municipal waste. Observe all relevant national regulations and dispose of the unit correctly. Observe all local and applicable laws. 7 / 12
8 Technical data Power supply unit for web server OZS164 Operating voltage Rated voltage Frequency Power consumption OZS164 (incl. power supply unit) Protection class Output voltage Supply line fusing AC V 10 % AC V 50 / 60 Hz 3 VA typical II SELV 24 VDC Max. 16 A Cable length (distance 230 VAC plug to web server) Max. 1.6 m. Web server OZS164 Operating voltage SELV 24 VDC 5 %, 625 ma max. Power consumption 2 W typical Functional data Clock reserve Min. 72 h Device list 1 Bus device Connection terminals PC interface LPB/BSB bus Ethernet Digital inputs Screw terminals for 1 solid wire per terminal 1 stranded wire per terminal. Interface Standard Device class Baud rate Connection cable for operator station Cable length Cable type for connection to PC/laptop Cable type for connection to OZS164 Interface type 2-wire bus Bus load Permissible line length and cable types Interface type Bit rate Protocol Identification Connection Cable type Cable length Interface type Voltage at open contact Current at closed contact mm mm 2 USB V2.0 RNDIS Max. 12 Mbps (full speed) Max. 3 m USB type A USB type Mini-B 2-wire connection DB/CL+, MB/CL (non-exchangeable) E 0.6 See: - Albatros2 System manual P Local Process Bus System engineering basic documentation P BaseTX, IEEE compatible 100 Mbps TCP / IP Auto MDI-X RJ45 plug (screened) Standard Cat-5, UTP or STP Max. 100 m Protective low voltage for potential-free low voltage-capable contacts DC (16 19) V DC (4...6) ma Industry standards Product safety Information technology equipment - Safety EN Electromagnetic compatibility Immunity (Industrial sector) Emissions (Residential, commercial and industrial sectors as well as small business) Radio communications (OZS164.23) -Conformity EMC directive Low voltage directive Ecodesign directive (power supply unit) R&TTE (Radio & Telecom. Equipment) (OZS164.23) EN EN EN , EN EN /108/EC 2006/95/EC 2005/32/EC 1999/5/EC 8 / 12
9 -Conformity (OZS164.13) Australian Radio Communication Act EN Conformity (OZS164.23) Australian Radio- and Telecommunication Act EN EN , EN EN Environmental compatibility The product environmental declaration E5711en contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal) ISO (environment) ISO 9001 (quality) SN (environmentally compatible products) 2002/95/EC (RoHS) Degree of protection Degree of protection of housing OZS164 IP 30 as per EN Safety class OZS164 III as per EN Ambient conditions Materials and colors Dimensions Weight Operation Climatic conditions Temperature (housing and electronics) Humidity Mechanical conditions Transport Climatic conditions Temperature Humidity Mechanical conditions Upper housing section Lower housing section OZS (without antenna): Length x width x height (max. dimensions) OZS (with antenna): Length x width x height (max. dimensions) OZS Full unit Complete device (basic unit with packaging, installation instructions, power supply unit, USB and Ethernet cable, cable ties) OZS Full unit Complete device (basic unit with packaging, installation instructions, power supply unit, USB and Ethernet cable, cable ties) Packaging IEC Class 3K C % r. h. (non-condensing) Class 3M2. IEC Class 2K C < 95 % r. h. Class 2M2 PC + ASA, RAL 7035 (light-gray) PC + ASA, RAL 5014 (dove blue) 87.5 mm x 90 mm x 40 mm 87.5 mm x mm x 40 mm kg kg kg kg Cardboard box Terms, abbreviations Auto Medium Dependent Interface - Crossed Auto MDI-X Dynamic Domain Name System DynDNS Hyper Text Transfer Protocol HTTP Internet Protocol IP Konnex KNX Network Address Translation NAT Port and Address Translation PAT Remote Network Driver Interface Specification RNDIS Shielded Twisted Pair STP Simple Mail Transfer Protocol SMTP Transmission Control Protocol TCP Universal Serial Bus USB Unshielded Twisted Pair UTP 9 / 12
10 Connection diagrams Connection terminals A DB/CL+ DB/CL+ DB/CL- DB/CL- D1 M C D2 M * GSM: OZS only Power supply unit Type Euro plug per EN and VDE For 230 VAC External voltage plug 24 VDC plug 1 24 VDC (+) 2 GND ( ) Pin assignments USB plug Type Mini-B 1 VCC 4 ID 2 D 5 GND 3 D + Ethernet plug RJ45 (standard assignment) 1 Tx + 5 Unassigned 2 Tx 6 Rx 3 Rx + 7 Unassigned 4 Unassigned 8 Unassigned LPB/BSB connections Terminal assignment A 1 DB/CL+ 2 DB/CL+ 3 MB/CL- 4 MB/CL- Digital inputs Terminal assignment C 1 D1 2 M 3 D2 4 M 10 / 12
11 Connection diagram P1 P2 N2 5711A02 DC 24 V LPB/BSB D1 M D2 M DB/CL+ MB/CL- N1 N1 Web server N2 LPB/BSB device P1, P2 Devices with potential-free contact output for fault indication Dimensions / 12
12 12 / Siemens Switzerland Ltd Subject to change
OZW772... V2.0. Web server. Synco TM, Synco TM living
s 5 701 Web server Synco TM, Synco TM living OZW772... V2.0 The OZW772 web server allows for remote operation and monitoring of plants via the web and send faults and system reports to e-mail recipients.
More informationOZW672...V5.2. Web-Server. For LPB/BSB plants
s 5 712 Web-Server For LPB/BSB plants OZW672...V5.2 Web server OZW672 allows for remote plant control and monitoring via the web and Smartphone-App. Web server is available in three versions: To connect
More informationOZW772... V4.0. Web server. For Synco TM, Synco TM living
s 5 701 Web server For Synco TM, Synco TM living OZW772... V4.0 Web server OZW772 allows for remote plant control and monitoring via the web and Smartphone-App. Four versions of the web server are available:
More informationWeb-Server OZW772... V5.2
s 5 701 Web-Server OZW772... V5.2 For Synco TM, Synco TM living Web server OZW772 allows for remote plant control and monitoring via the web and Smartphone App. Four versions of the web server OZW772...
More informationQFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationRRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
More informationHCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationOZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationWeb server OZW672 V3.0 Commissioning instructions
s LPB and BSB plants Web server OZW672 V3.0 Commissioning instructions OZW672.01 OZW672.04 OZW672.16 CE1C5712en 06.06.2011 Building Technologies Siemens Switzerland Ltd Building Technologies Division International
More information5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
More informationLevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationGEU-0822 8-Port Gigabit Switch
GEU-0822 8-Port Gigabit Switch 1 V1. 1_20150622 1. INTRODUCTION... 3 1.1 Product Briefs... 3 1.2 Product Features... 3 1.3 Hardware Introduction... 4 2. CONNECTING THE SWITCH... 5 2.1 Package Contents...
More informationIntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
More informationFor UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.
s For UK only RX39.1 and the applications package SP-03 are sold in the United Kingdom only. 3 876 3876P01 RX Room controller Communicating controllers for fan-coil applications SP-03 RX39.1 The RX39.1
More informationAXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
More informationIFS SP-PoE Splitter User Manual
IFS SP-PoE Splitter User Manual P/N 1069176-EN REV 1.01 ISS 01JUL10 2011 UTC Fire & Security. All rights reserved. Content Overview 2 Package contents 2 Introduction 3 Product Specifications 3 Hardware
More informationHeating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
More informationKNX Panasonic Air Conditioners
IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line
More informationSEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationWaveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
More informationQFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
More informationIntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
More informationSynco, Synco living Web server OZW772... V5.2 Commissioning instructions
s Synco, Synco living Web server OZW772... V5.2 Commissioning instructions OZW772.01 OZW772.04 OZW772.16 OZW772.250 CE1C5701en 2014-10-15 Building Technologies Siemens Switzerland Ltd Building Technologies
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationRDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
More informationIntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
More informationQuick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
More informationWeb server OZW672... V5.2 Commissioning instructions
s LPB and BSB plants Web server OZW672... V5.2 Commissioning instructions OZW672.01 OZW672.04 OZW672.16 CE1C5712en 2014-10-15 Building Technologies Siemens Switzerland Ltd Building Technologies Division
More informationLBNP16312. RS-232/485/422 serial device server. User manual
Tu Sitio de Automatización! LBNP16312 RS-232/485/422 serial device server User manual Summarize-----------------------------------------------------------------------------14-3 Package checklist---------------------------------------------------------------------14-3
More informationDCS Data and communication server
8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With
More informationEngineering and service software For KNX and LPB plants
5 649 Engineering and service software For KNX and LPB plants As of V9.00 ACS790 The engineering and service software ACS790 is for KNX and LPB plants equipped with the appropriate bus devices. The software
More informationIntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
More informationZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
More informationIntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
More informationENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
More informationXUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm
Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
More informationRVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
More informationSHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series
EIPR Series d a t a SHEET EIPR Skorpion Wired and Wireless IP Routers The EIPR links two Internet Protocol (IPv4) networks together passing appropriate traffic while blocking all other traffic. One of
More informationAXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
More information5-port 10/100Base-TX Industrial Switch (314500) User s Guide
5-port 10/100Base-TX Industrial Switch (314500) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
More informationHARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
More informationProduct and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
More informationAlarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6
Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit
More informationIDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited
(Rev. 1.0) China Aerospace Telecommunications Limited Contents 1. Introduction......3 2. Specifications...4 2.1 External Interface... 4 2.2 Status Indicator...... 5 2.3 Technical Parameters... 6 3. Device
More informationIEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual
IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400 User s Manual - 1 - Trademarks Disclaimer Copyright PLANET Technology Corp. 2006. Contents subject to revision without prior notice. PLANET
More informationR60 USB to CAN interface Manual (1.5 EN)
R60 USB to CAN interface Manual (1.5 EN) General information R60 USB to CAN interface Manual Version 1.5 EN, 02/2010, DOC01586 Copyright 2010 by ; all rights reserved. Eugen-Adolff-Strasse 134, D-71522
More informationHARTING econ 3000 Introduction and features
HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications
More informationDanfoss Link Mobile Phone Butler
MAKIG MODER LIVIG POSSIBLE Installation Guide www.heating.danfoss.com Table of Contents 1 Introduction... 3 2 Installation... 3 3 Interfaces... 4 4 Wiring... 4 5 SMS Commands... 5 6 Technical Specifications...
More informationTechnical Support. Support Information
Technical Support Please refer to the Support Information card that shipped with your product. By registering your product at www.netgear.com/register, we can provide you with faster expert technical support
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationPXM20-E. Operator unit DESIGO PX
9 234 DESIGO PX Operator unit PXM20-E Network-compatible operator unit for viewing and operating one or more DESIGO PX automation stations. High-grade display with adjustable contrast Simple key operation
More information16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide
16-port Gigabit Switch 10/100/1000 Mbps GS116 Installation Guide Introduction The NETGEAR 16-port Gigabit Switch Model GS116 provides you with a low-cost, reliable, high-performance switch to connect up
More informationIndustrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
More informationDifferential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
More informationEZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014
EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware
More informationProduct Specifications
Cisco Model EPR2320 EuroDOCSIS 2.0 Residential Gateway with Wireless Access Point The Cisco Model EPR2320 EuroDOCSIS 2.0 Residential Gateway (EPR2320) combines a cable modem, router, and wireless access
More informationalpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS
alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS Safety precautions Safety precautions The DSL modem alpha DSL WTM HS complies with the European norm EN60950 safety of information technology
More informationBLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1
BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved
More informationMoxa EtherDevice Switch
Moxa EtherDevice Switch EDS-205 Hardware Installation Guide Third Edition, June 2008 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. P/N: 1802002050000 Overview The
More informationDES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch
DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch Manual RECYCLABLE V1.01 TABLE OF CONTENTS About This Guide... 1 Purpose... 1 Introduction... 2 Fast Ethernet Technology... 2 Switching Technology...
More informationProduct Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject
More informationIntesisBox KNX Mitsubishi Heavy Industries AC
IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)
More informationIPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network
IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This
More informationUser manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
More informationModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
More informationModbus Server SAMSUNG Air Conditioners
IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationTK800-Series Industrial GPRS / UMTS / LTE Router
The new generation LTE with 100 Mbps LTE standard for high transmission rates and good network coverage in sparsely populated areas Dynamic Multipoint VPN GRE, L2TP, IPSec, DMVPN, OpenVPN Simple and fast
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationPoE+ Extender Switch User's Manual. Rev. 2.00-60W
PoE+ Extender Switch User's Manual Rev. 2.00-60W We make no warranties with respect to this documentation and disclaim any implied warranties of merchantability, quality, or fitness for any particular
More informationPerle 10/100 Ethernet Media Converters
Perle 10/100 Ethernet Media Converters Installation Guide S-110-XXXXXX S-110-XXXXXX-XT P/N 5500302-16 (Rev B) Overview This document contains instructions necessary for the installation and operation of
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationMDI/MDIX) FEP-32008T-3
TM Mico-Switch/8 8 Port 10/100Base-TX Switch (Auto MDI/MDIX) FEP-32008T-3 U SER S M ANUAL (Auto MDI/MDIX) FEP-32008T-3 TM TM Package Contents Package contents include the following: Micro-Switch/8; 8 Port
More informationTerminal and Dimension
Ethernet Extender Model Number: SJ-L-DSL Product Description Product Features SJ-L-DSL is a network signal extension device, which consists of remote unit and local unit. It can transmit network signal
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationBODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES
NOTES BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Important
More informationNS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing
NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing Introduction: NS-205-IP67 Ethernet Switches are designed for use in industrial waterproof/harsh environments. The rugged packaging
More informationUSER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
More informationQSE-CI-NWK-E Control Interface
QSE-CI-NWK-E Control Interface 369373e 1 04.05.16 The QSE-CI-NWK-E is a versatile integration access point for Lutron QS-based systems. Through either RS232 or TCP / IP over Ethernet, third-party devices
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationALL8808POE. 8 Port Gigabit PoE+ Switch. Manual
ALL8808POE 8 Port Gigabit PoE+ Switch Manual FCC Certifications This Equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
More information1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
More information8-Port PoE Network Switch
Page 1 of 12 8-Port PoE Network Switch User s Guide Document Number 91I00-1 Rev A August, 2009 FCC Warning: Page 2 of 12 This devices has been tested and found to comply with the regulations for Class
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
More informationWireless Router Setup Manual
Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,
More informationAir damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
More informationIntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
More informationECR Shelf System Installation Guide Centralized Rack Mount Call Recording
Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com support@algosolutions.com www.algosolutions.com
More informationIntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.
IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A
More informationGigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide
Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608 Installation Guide Introduction The NETGEAR 5/8-Port Gigabit Ethernet Switch Model GS605 / GS608 provides you with a high-speed, reliable, easy-to-use
More informationN300 WiFi Range Extender
Model EX2700 User Manual July 2014 202-11395-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on
More informationCAN@net II Intelligent PC/CAN Interface. Manual
CAN@net II Intelligent PC/CAN Interface Manual IXXAT Automation GmbH Leibnizstr. 15 D-88250 Weingarten Tel.: +49 (0)7 51 / 5 61 46-0 Fax: +49 (0)7 51 / 5 61 46-29 Internet: www.ixxat.de e-mail: info@ixxat.de
More informationACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
More informationHDMI / Video Wall over IP Transmitter with PoE
/ Wall over IP Transmitter with Key Features Network 1080P ultra high quality video transmitter Assigns video sources to any monitor of the video wall Up to 8 x 8 Screen Array supported Extends high definition
More informationNetworks. The two main network types are: Peer networks
Networks Networking is all about sharing information and resources. Computers connected to a network can avail of many facilities not available to standalone computers: Share a printer or a plotter among
More information