MechoNet TM Network Interface (MNI) Specification Submittal



Similar documents
ADACSNET USB Control Module

DATA BOOK. for bioclimatic facades

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Reference Design. conference rooms

PCS0100en Persy Control Services B.V. Netherlands

T7560A,B,C Digital Wall Module

LocoNet, the Digitrax Difference

QSE-CI-NWK-E Control Interface

GEU Port Gigabit Switch

HomeWorks QS Processor

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

HARTING econ 3000 Introduction and features

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

connecdim Gateway G1 Ethernet TCP/IP to DALI

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

UCC 1 USB-CAN CONVERTER

Electronic Control Devices The European Product Catalogue 2007

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

BACnet Automation Interface Module (Network Version)

DCS Input/Output Relay Card Series

EMBEDDED ACCESS CONTROL Hardware Installation Guide

is then retained absolutely without interruption.

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

PagePac PAGEPAL V

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

Electronic Control Devices The European Product Catalogue 2007

T1 Backhaul Connectivity Solution All Products :: Application Note

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

Climate Ready Control Systems Technical Specifications

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Network Design. Yiannos Mylonas

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

CAT5 Video Display Quick Installation Guide

USB Rover port USB m Cat 5 Extender. User Guide

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

KVM - DVI, USB 2.0, Cat 5 Extender

PS/2 KVM Console Extender User Manual (GCE250)

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

F2400 FOM II Series Fiber Optic Modem Technical Manual

Moxa TCC-100/100I User s Guide

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

AXIS T81B22 DC 30W Midspan

Model CFA-24 Transparent Cable Farm Automation Switch

DeltaV SISnet Repeater

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Perle 10/100 Ethernet Media Converters

Climate Ready Shade Operating Systems for residential applications.

SMARTen 24 STP Patch Panels

Application/Connection Examples

O C M III. Open Channel Flow Monitor

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

PXL-250: Network Wiring

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

HT-150 Owner s Manual

Industrial Bar Code Scanners

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

L5354 ControlNet Communications Interface

Applied Electronics. Commercial Dimming System UPDATE NOTICE

MDI/MDIX) FEP-32008T-3

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Configuration Instructions

Installation and User Guide

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Ethernet Cat 5e & Cat 6 Patch Panels

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

Networks. The two main network types are: Peer networks

FlexPoint T1/E1 Copper to Fiber Line Driver

400 Series - Mini USB Buccaneer

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

USB Port Extender Kit

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

SECTION LOW VOLTAGE LIGHTING CONTROLS

Terminal and Dimension

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

Contents. Document information

Transcription:

MechoNet TM Network Interface (MNI) Specification Submittal Models MechoNet Network Interface: MNI RJ (RJ45 Motor Ports): Stock No.: IMNI 0001 TP AS (US version) Stock No.: IMNI 0004 TP AS (UK version) MechoNet Network Interface: MNI TB (Terminal Block Motor Ports): Stock No.: IMNI 0002 TP AS (US version) Stock No.: IMNI 0005 TP AS (UK version) Features Front View (MNI RJ, US) Rear View (MNI RJ, US) Low voltage controller expands window covering control over MechoNet. Four (4) optically isolated, low voltage Motor / Electronic Drive Unit (EDU) ports control shades, blinds and draperies. Each Motor Port is configurable to support: o WhisperShade IQ roller shades and blinds o Somfy ILT2, FTS, DCT or RTS roller shades and blinds. o WhisperTrac 1000 or 3000 series drapery tracks. o Somfy Glydea TM DCT or RTS drapery tracks. Two models (MNI RJ, MNI TB) simplify motor wiring options. Configurable port personalities enable virtually any company s User Interface (UI) to operate window coverings. Four (4) optically isolated Switch Ports expand dry contact control options to keypads, sensors and third party controls. Each Switch Port and Motor Port supports up to five (5) alignment points and three (3) customizable presets. Uniform Mode setting maintains an architect s design intent at all times. One (1) IR remote control port supports various wireless IR remotes. One (1) configurable Serial Port for two way RS232 or RS485 communication facilitates third party integration. Two (2) MechoNet Ports facilitate cost effective daisy chain wiring over MechoNet. MechoNet expands group control options across up to 250 nodes over 4000 ft. (1219.2m) of standard CAT 5 or CAT 6 cable. Each Motor Port possesses ten (10) MechoNet group control addresses which enable flexible, multilevel control options. Flexible power options can eliminate the need for a dedicated 24VDC supply. Five (5) diagnostic LEDs aid in troubleshooting configuration and wiring issues. Firmware and port configurations are upgradable from any point on the network without climbing a ladder! Settings are stored in non volatile memory with a minimum ten year life which recalls settings even in case of power failure. The MechoNet Network Interface is a listed solution to UL325 and CSA 22.2 No. 247. Description The MechoNet Network Interface (MNI) serves as a communication and control hub for motorized window coverings. Managing control for up to four (4) window covering motor or EDU connections, its low voltage Motor Ports can control a variety of roller shade, blind, and drapery solutions via dry contact. Its complementary four (4) Switch Ports, IR Port and Serial RS232/485 Port provide expansive control options to a variety of dry contact, wireless, and third party controls. Virtually any company s switch, keypad, touchscreen, remote, or app can be applied to control window coverings attached to the MNI or MechoNet. MechoSystems awardwinning MechoNet network is a bidirectional communication bus that provides flexibility, reliability, and scalability from single office to whole building control. Each MNI Motor Port possesses ten (10) MechoNet control addresses in order to support complex overlapping, multilevel control schemes (individual, group, master, and others). In addition, control can also be extended to MechoSystems SolarTrac and SunDialer automated WindowManagement Systems bringing the ultimate in energy efficiency combined with optimized comfort, exposure to natural daylight, and views. PC based tools support field configuration and troubleshooting from anywhere on the control network.

MNI Specification Submittal Page 2 of 8 Electrical Specifications Power Port Power Input (+, ) 12 28VDC, 200mA Max Connector 2 position 3.5mm pluggable terminal block (See Right & Fig. 1) Wiring 2 conductor UTP, 18 AWG, stranded, 500 ft. (152.4m) Max (See Fig. 1) Motor Ports (M1, M2, M3, M4) Dry Contact Outputs (B1, B2, B3) 12 28VDC, 25mA Max (sink) per Output, 330Ω Power Input (PWR M1, PWR M2, etc.) 12 28VDC @ 75mA Max per Port Feedback Signal (FB IN) 28VDC Max, 2KΩ Source Impedance Connector IMNI 0001 / IMNI 0004 RJ45, USOC Crimp (See Right & Fig. 1) IMNI 0002 / IMNI 0005 4 position 3.5mm pluggable terminal block (See Right & Fig. 1) Wiring IMNI 0001 / IMNI 0004 8 conducter 4UTP, Cat 5/6, 400 ft. Max (See Fig. 1) IMNI 0002 / IMNI 0005 4 conductor, 18 24 AWG, stranded, 400 ft. (121.9m) Max (See Fig. 1) Switch Ports (S1, S2, S3, S4) Switch Port Power (PWR SW) 12 28VDC, 25mA Max Dry Contact Inputs (B1, B2, B3) 12 28VDC, 2KΩ (Source) Feedback Signal Output (FB OUT) 12 28VDC, 2KΩ (Sink) Connector RJ45, USOC Crimp (See Right & Fig. 1) Wiring 8 conductor 4UTP, Cat 5/6, 400 ft. (121.9m) Max (See Fig. 1) Power Connector RJ45 Connector TB Motor Connector RJ45 Connector MechoNet Ports (IN*) MechoNet Power Input (PWR or V+) 12 28VDC, 1A Max MechoNet (NET A, NET B) +13.0VDC Max/ 8.0VDC Min, 60mA Max Connector RJ45, USOC Crimp (See Right & Fig. 1) Wiring 8 conductor, Cat 5/6 4UTP, 4000 ft. (1219.2m) Max, Max Nodes 250 (See Fig. 1) Serial Port (RS232/RS485) RS485_A, RS485_B (A, B) +13.0VDC Max/ 8.0VDC Min, 60mA Max RS232 TXD/RXD (TXD, RXD) +13.2VDC Max/ 13.2VDC Min, 2mA Max Connector RJ12 (See Right & Fig. 1) Wiring Cat 3/5/6 3UTP, 25 ft. (7.6m) Max (See Fig. 1) RJ45 Connector RJ12 Connector IR Port IR Port Power Output (PWR IR) Configurable 5.0/3.3VDC, 100mA Max IR Port Signal Input (IR) 3.3VDC, 300uA (Sink) Connector R12 (See Right & Fig. 1) Wiring 6 conductor, 26 AWG Silver Satin Cable or UTP Cat 3/5/6, 5 ft. (1.5m) (See Fig. 1) RJ12 Connector

MNI Specification Submittal Page 3 of 8 Connections: Figure 1: MNI Connection Diagram

MNI Specification Submittal Page 4 of 8 Mechanical Specifications IMNI 0001 TP AS / IMNI 0002 TP AS (US Form) PCB Assembly Size: Packaging: Size: Weight: 3.5 in. (88.9mm) x 3.5 in. (88.9mm) Mounts within a 4 11/16 in. (120.7mm) X 3 in. (76.2mm) Steel JBox (provided by others) 4.75 in. (120.7mm) X 4.75 in. (120.7mm) X 1 in. (25.4mm) (see Fig.2) 0.5 lbs. (0.23kg) MNI RJ/MNI TB (US Form) 0.63 in. (15.9mm) Figure 2: Dimensional View US version 4.75 in. (120.7mm) 3.5 in. (88.9mm) 4.75 in. (120.7mm) 1 in. (25.4mm) (Provided by Others) 3 in. (76.2mm)

MNI Specification Submittal Page 5 of 8 Environmental Specifications Temperature Operating: 32 to 131 o F (0 to 55 o C) Humidity Operating: < 90% relative humidity, non condensing Warranty & Technical Support Limited warranty on motors and electronics to be free of manufacturing defects in factory materials or workmanship for five years from the date of shipment. T: +1 (718) 729 2020, x2006 W: mechosystems.com E: techsupport@mechosystems.com MechoSystems reserves the right to make improvements or changes in its products without prior notice. However, every attempt is made to ensure the information herein is accurate and up to date. Verify with MechoSystems to confirm the product availability, latest specifications, and suitability for your application Low Voltage Cable Legend for Wiring Diagrams A A1 A2 CAT/6E FOR LOW VOLTAGE DRY CONTACT CONNECTIONS 24 AWG 4UTP (8 CONDUCTOR STRANDED UNSHIELDED TWISTED PAIR) OLYMPIC WIRE AND CABLE (WWW.OLYMPICWIRE.COM 1 800 526 2269) PART No. 3078M5FH. TERMINATION: RJ45 MODULAR PLUG CRIMPED (USOC) ON BOTH ENDS CAT5/6E FOR LOW VOLTAGE DRY CONTACT CONNECTIONS IN PLENUM AREAS 24 AWG 4UTP (8 CONDUCTOR SOLID UNSHIELDED TWISTED PAIR) OLYMPIC WIRE AND CABLE (WWW.OLYMPICWIRE.COM 1 800 526 2269 PART No. 3604M55 SOLID CONDUCTOR RJ 45 MODULAR PLUGS CRIMPED (USOC) ON BOTH ENDS DISTANCE LIMITATION: 400' CUMULATIVE CAT56E CABLE FOR SDNET 24 AWG 4UTP (8 CONDUCTOR STRANDED UNSHIELDED TWISTED PAIR) TERMINATION: RJ 45 MODULAR PLUG CRIMPED (USOC) ON BOTH ENDS DISTANCE LIMITATION: 4000' CUMULATIVE. MAX. NETWORK NODES: 16. CAT5/6E CABLE FOR ETHERNET CONNECTIONS 24 AWG 4UTP (8 CONDUCTOR STRANDED UNSHIELDED TWISTED PAIR) TERMINATION: RJ 45 MODULAR PLUG CRIMPED (EIA568A) ON BOTH ENDS DISTANCE LIMITATION: 325'. MAX. NETWORK NODES: 2. A4 A6 C CAT5/6E CABLE FOR RS 232 CONNECTIONS 24 AWG 3UTP (6 CONDUCTOR STRANDED UNSHIELDED TWISTED PAIR) TERMINATION: RJ 12 MODULAR PLUG CRIMPED (USOC) ON BOTH ENDS DISTANCE LIMITATION: 25' CUMULATIVE. CAT5/6E CABLE FOR MECHONET 24 AWG 4UTP (8 CONDUCTOR STRANDED UNSHIELDED TWISTED PAIR) TERMINATION: RJ 45 MODULAR PLUG CRIMPED (USOC) ON BOTH ENDS DISTANCE LIMITATION: 4000' CUMULATIVE. MAX. NETWORK NODES: 250. BELDEN TYPE 82760 18 AWG 1STP (2 CONDUCTOR SHIELDED TWISTED PAIR) FOR PC INTERFACT/ANALOG I/O TO SENSOR CONNECTIONS PHOENIX CONNECTOR/CONNECTION + = RED = BLACK + = BLUE/RED = GREY/BLACK DISTANCE LIMITATION: 500' CUMULATIVE NOTES 1. PARALLEL WIRING TO NEXT DEVICE PER BRANCH CIRCUIT CAPACITY. ALL CONNECTIONS MUST MEET NATIONAL AND LOCAL CODES AND REGULATIONS. 2. ADDRESS SCHEDULES REQUIRED. 3. MAXIMUM VOLTAGE FOR ALL UNMARKED CABLE IS 43.5 VDC. 4. LOW VOLTAE CABLES SHOULD NOT BE ROUTED NEAR POWER LINES OR ELECTRICAL DEVICES SUCH AS LIGHTING BALLASTS, DIMMERS AND LED DRIVERS THAT MAY EXPOSE THE SYSTEM TO EXCESSIVE ELECTRICAL NOISE.

MNI Specification Submittal Page 6 of 8 MechoNet Network Interface (MNI) System Diagram SEE PAGE 5 FOR LOW VOLTAGE CABLE LEGEND SIX CONDUCTOR 24 GUAGE FLAT MODULAR CABLE, 25 O MAX. LENGTH (FURNISHED AND INSTALLED BY OTHERS)

MNI Specification Submittal Page 7 of 8 MechoNet Network Interface (MNI) Sample Point To Point Diagram (MNI RJ) SEE PAGE 5 FOR LOW VOLTAGE CABLE LEGEND (Optional)* *WhisperShade IQ2 or IQ/MLC2 can power a single MNI via their IN1 or M$1 ports respectively.

MNI Specification Submittal Page 8 of 8 MechoNet Network Interface (MNI) Sample Point To Point Diagram (MNI TB) SEE PAGE 5 FOR LOW VOLTAGE CABLE LEGEND MNI TB (Optional)* *WhisperShade IQ2 or IQ/MLC2 can power a single MNI via their IN1 or M$1 ports respectively. MechoNet Network Interface MNI Specification Submittal 102414.docx