Splicing and Fiber Assembly Compatibility for Non-Zero Dispersion-Shifted Fiber and Standard Single-Mode Fiber



Similar documents
SPLICE LOSS IN NON-ZERO DISPERSION-SHIFTED FIBERS

Field Measurements of Deployed Fiber

Fiber Optic Specifications

Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

Fiber-to-the-Home/FTTH

Attaching the PA-A1-ATM Interface Cables

Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

Guidelines. LANscape Solutions Recommended Fiber Optic Test Guidelines. Table of Contents. 1. Introduction. 2. Why Test? 1. Introduction...

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Cisco SFP Optics for Gigabit Ethernet Applications

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

FIBER OPTIC SYSTEM TEST PROCEDURES

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?

Insertion Losses of Fiber Optical Connectors

What testing is required for PREMISES Fiber Optic Cabling and the standards used

MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

An advanced Dark Fiber Monitoring System for Next Generation Optical Access Networks

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations

Cisco - Calculating the Maximum Attenuation for Optical Fiber Links

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

The following terms are defined within the context of the fiber optic industry

Accurately Testing fibre Optic Cables

home site map help ECMS Project: Standard / Federal Oversight Advertised

Patch Cords for Data Center Applications

Introduction to Optical Link Design

BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers

Overcoming OM3 Performance Challenges

CISCO 10GBASE X2 MODULES

Module 13 : Measurements on Fiber Optic Systems

SECTION TESTING OF FIBER OPTIC CABLES

OFS AllWave Zero Water Peak (ZWP) single-mode

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

Reliable, Consistent, Quality

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

QuickSpecs. Models HP X131 10G X2 CX4 Transceiver. HP X131 10G X2 Transceivers (SR, LRM, LR, ER and CX4) Overview. HP X131 10G X2 SC LRM Transceiver

7.4 3M No Polish Connector

Fibre optic testing best practices

HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS

Loss & Continuity Testing with MPO/ MTP Connectors

CamSplice Assembly Manual

Gigabit Passive Optical Networks

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

Patch Cord Quality, Reliability and Performance. The Impact of Industry Specifications and Physical Parameters on Patch Cord Performance

Compatibility of Bend Optimized Multimode Fibers White Paper. Issued September 2009

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

Measuring of optical output and attenuation

European Normative EN system

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

Designing Fiber Optic Systems David Strachan

New Direct Core Monitoring Fusion Splicer TYPE-71C+

Laser-Optimized Fiber

Ethernet/IEEE evolution

Testing Fiber Optic Cables. Rudy De Winter C.N. Rood

TransPacket white paper. CWDM and DWDM networking. Increasing fibre-optical network utilization and saving on switches/routers

Fundamentals of Fiber Cable Management

Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

Corning Specialty Fiber. Product Information Sheets

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

Industry solutions: Broad cast

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

Items Supplied. Frequency. Designation Description / Delivery Unit Order Number

APPLICATION NOTE POLARIZATION MEASUREMENTS

Optical Fibers Fiber Optic Cables Indoor/Outdoor

Fundamentals of Fiber Cable Management WHITE PAPER

Fiber Characterization Service

Fiber Optic Training Guide By Sarkis Abrahamian

Cable Assemblies. Corning Cable Systems

Fiber Optics: Engineering from Global to Nanometer Dimensions

200-Micron Single-Mode Fiber Enables New Cable Designs Copyright 2014 OFS FITEL, LLC

TURBOTEST 400 Fiber Optic Certification Test Set User s Guide

Fibre Channel Fiber Cabling

The Need for Low-Loss Multifiber Connectivity

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

Testing and troubleshooting enterprise fiber-optic cabling. Presenter: Neftali Usabal Fluke Networks - LATAM

Data Storage (Splicing result) Storage Condition

QuickSpecs. Models HP X132 10G SFP+ LC ER Transceiver. HP SFP+ Transceivers (SR, LRM, LR and ER) Overview

Security & Surveillance Cabling Systems

With the advent of Gigabit Ethernet

Special Specification 6033 Computerized Transportation Management System

Plug - Type (Male/Female) Attenuators CAA series Singlemode

Broadband Applications & Construction Manual. Fiber Optic Cable Products

Fiber Optic Connections in the Sea

Fiber Selection and Standards Guide for Premises Networks

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

Transcription:

Presented at NOC/EC 2000 Splicing and Fiber Assembly Compatibility for Non-Zero Dispersion-Shifted Fiber and Standard Single-Mode Fiber Mary Adcox, Optical Fiber, Corning Incorporated As non-zero dispersion-shifted fibers () become more prevalent in the marketplace, system designers are interested in ensuring compatibility with the existing fiber plant. NZ-DS fibers, such as Corning LEAF fiber with large, Corning SMF-LS fiber and Lucent Truewave fiber, are optimized for long distance, high data rate operation over the 1550 nm window. In this region, they have much lower dispersion than standard single-mode fiber. To obtain the desired dispersion and properties, NZ-DS fibers are fabricated with more complex physical profiles than standard single mode fiber. Also, for SMF-LS and Truewave fibers, the and corresponding mode field diameter values are smaller than for fibers with large such as LEAF fiber (see Table 1). Because of these differences, NZ-DS fibers are effected more by critical parameters such as splicing conditions and procedures. To quantify this sensitivity and address compatibility with fiber assemblies such as pigtails and jumper cables, Corning Incorporated initiated a series of studies to compare NZ-DS fibers with single-mode fiber (SMF). How NZ-DS Fibers Compare With SMF Non-zero dispersion-shifted fibers are designed for multiple high bit-rate wavelengths in the 1550nm wavelength region over long system lengths. Single-mode fiber is optimized for use in the 1310 nm wavelength region, although 1550nm operation is possible at 10 gigabits per second but requires careful management of the dispersion. Table 1 summarizes some of the differences between the various fiber types: Table 1: Summary of the differences between the various fiber types SMF with large Attenuation @ 1550 nm 0.25 db/km 0.25 db/km 0.25 db/km Typical Dispersion @ 1550 nm 17 ps/nm*km 4.2 ps/nm*km 4.5 ps/nm*km Effective Area 80 µm 2 72 µm 2 50 µm 2 to 55 µm 2 Mode Field Diameter Range @ 1550 nm 9.6 µm to 11.2 µm 9.2 µm to 10.0 µm 7.8 µm to 9.0 µm Page 1 of 7

NZ-DS fibers are more inherently more sensitive to splicing due to their more complex physical design. The end angle of the cleave, splicing equipment and clean splicing conditions, are all critical parameters to achieving consistently low splice loss. Splice loss is more sensitive to cleave end angle when splicing compared with standard single-mode fiber. The impact of cleave end angle has been documented for the original dispersionshifted fiber designs. Laboratory studies of the earlier designs show that end angles greater than two degrees can more than double the splice loss as compared to standard single-mode fiber, as indicated in Figure 1. Similar effects would be expected for. 0.3 0.25 Average Blind Splice Loss (db) 0.2 0.15 0.1 0.05 Dispersion-Shifted Single-Mode Fiber 0 Standard Single-Mode Fiber -0.05 0 0.5 1 1.5 2 2.5 3 3.5 End Angle (degrees) Figure 1: The effect of end angle on splice loss Fortunately, splicing equipment continues to improve so that it is capable of splicing the new, more complex fiber designs. Manufacturers now offer adjustable machine settings that optimize splice performance for NZ-DS fibers and continue to refine splice loss algorithms that provide more accurate splice loss estimations. Splicing equipment manufacturers should be contacted directly for specific recommendations. As always, cleanliness of the work area and equipment as well as equipment maintenance play an important role in achieving quality splices. The fiber stripper, cleaver and the splicer all have to be in top notch working condition. Time spent in advance preparation of the work area and equipment will increase productivity. As early experience with SMF and recent experience with indicated, uni-directional optical time domain reflectometer (OTDR) measurement of splice loss can be deceiving. Uni-directional measurements may indicate too high of a splice loss, while, in fact, the splice loss obtained with a bidirectional measurement proves low splice loss. Because of this, bi-directional measurements must Page 2 of 7

be made to obtain accurate, reliable splice loss values. The uni-directional measurement error is primarily a function of the differences in the mode-field diameter (MFD) of the two fibers. There are two factors to consider regarding the effect of mode-field mismatch when measuring splice loss. 1. The actual contribution to splice loss due to MFD mismatch, which is independent of the direction of measurement. 2. When measuring by OTDR, the apparent loss due to the way an OTDR performs measurements, which is an artifact of the OTDR measurement, and appears as a 'gainer' in one direction and a high loss in the other direction. users should expect to see greater occurrences of high one-way OTDR measurements due to the fiber's smaller MFD versus standard single-mode fiber. However, bi-directional testing of these splices will result in acceptable splice loss values. Typically, because of the larger MFD, single-mode fiber splice loss values are lower than those of NZ-DS fibers. Single-mode fiber's splice loss averages between 0.2 and 0.3 db, while typical NZ-DS fiber's splice loss averages between 0.4 and 0.5 db. For all the various fiber types, the average splice loss values are well within typical splice loss budgets. When splicing together two different types of fibers or hybrid fibers, elevated splice loss (both unidirectionally measured and actual splice loss values) should be expected due to mode field diameter mismatch. The MFD range for the different fibers are shown in Table 2. Fiber MFD Range @ 1550 nm SMF 9.6 µm to 11.2 µm with large 9.2 µm to 10.0 µm 7.8 µm to 9.0 µm Table 2: Mode field diameters of various fiber types As with heterogeneous fibers, hybrid fibers require either a bi-directional measurement by OTDR or a power through loss measurement. By performing OTDR bi-directional averaging, it is possible to eliminate backscatter effects and get the true splice loss, avoid over or under estimating splice loss and prevent unnecessary re-splices. Splice studies for SMF, and with large were recently completed at Corning s Center for Fiber-Optic Testing. An active alignment splicer was used in all of the studies. The fibers selected for the studies included a wide range of mode-field diameters and core/clad offsets. Standard single-mode fiber splice settings were selected when performing the splicing. Because splicer set-up varies between models, it is suggested the splicing equipment manufacturers be contacted for recommended equipment set-up. Page 3 of 7

Keep in mind, when splicing dissimilar fibers, splice loss performance is better the closer the fibers mode field diameters are. As shown below, when splicing with large to SMF, splice loss performance is better than when splicing to SMF: Splice Loss (db) @ 1550 nm with large to SMF to SMF Number of Splices 66 18 Average 0.11 0.15 Std. Dev. 0.029 0.028 With a proper understanding of the importance of bi-directional OTDR measurement in achieving accurate splice loss measurements, splicing to itself and to SMF results in excellent splice performance. Using SMF Assemblies in Routes It is not necessary to use for pigtails and jumper cables in typical routes. In fact, Corning recommends the continued use of SMF pigtails and jumper cables in all systems. Table 3 shows a study that compares the use of pigtails and jumper cables in routes. The following schematic displays the set-up at Site A. Typical splice and connector values are used to compare the expected performance differences of the two systems: PIGTAIL PIGTAIL TO JUMPER CONNECTION AT BACKPLANE EDFA OSP CAB PREMISES CABLE JUMPER SPLICE TO OSP CABLE EDFA to PIGTAIL SPLICE SPLICE POINT AT SPLICE BAY JUMPER CONNECTION AT FIBER DISTRIBUTION Schematic of Site A Page 4 of 7

Typical Performance Budget Item Using SMF Assemblies Using Assemblies EDFA to pigtail splice 0.02 db SMF to SMF 0.15 db SMF to Pigtail to jumper connection at 0.25 db SMF to SMF 0.34 db to 0.25 db SMF to SMF 0.34 db to Splice point at splice bay 0.02 db SMF to SMF 0.04 db to Splice to OSP cable 0.15 db SMF to 0.04 db to Total at Site A (1-5) 0.69 db 0.91 db Splice to OSP cable 0.15 db SMF to 0.04 db to Splice point at splice bay 0.02 db SMF to SMF 0.04 db to 0.25 db SMF to SMF 0.34 db to Jumper to pigtail connection at 0.25 db SMF to SMF 0.34 db to Fiber-detector pigtail --------- Note 2 --------- Note 2 Total at Site B (6-10) 0.67 db 0.76 db Total Loss at Site A & B 1.36 db 1.67 db Advantage of using SMF assemblies instead of assemblies = 0.31 db Table 3: Expected performance for SMF and assemblies in systems Table 4 contains a study that compares the use of with large pigtails and jumper cables in with large routes: Typical Performance Budget Item Using SMF Assemblies Using with Large Effective Area Assemblies EDFA to pigtail splice 0.02 db SMF to SMF 0.11 db SMF to w/large effective area Pigtail to jumper connection at 0.25 db SMF to SMF 0.29 db w/large effective area to w/large 0.25 db SMF to SMF 0.29 db w/large effective area to w/large Splice point at splice bay 0.02 db SMF to SMF 0.05 db w/large effective area to w/large Splice to OSP cable 0.11 db SMF to 0.05 db w/large effective Page 5 of 7

w/large Total at Site A (1-5) 0.65 db 0.79 db Splice to OSP cable 0.11 db SMF to w/large area to w/large 0.05 db w/large effective area to w/large Splice point at splice bay 0.02 db SMF to SMF 0.05 db w/large effective area to w/large Jumper to pigtail connection at 0.25 db SMF to SMF 0.29 db w/large effective area to w/large 0.25 db SMF to SMF 0.29 db w/large effective area to w/large Fiber-detector pigtail --------- Note 2 --------- Note 2 Total at Site B (6-10) 0.63 db 0.68 db Total Loss at Site A & B 1.28 db 1.47 db Advantage of using SMF assemblies instead of with large assemblies = 0.19 db Table 4: Expected performance for SMF and with large assemblies in with large systems Page 6 of 7

For both comparisons, the following criteria was used: Assumptions: Connector Loss Typical MFD Fiber-Detector Loss SMF.25 db 10.4 µm See Note 2 w/large.29 db 9.6 µm See Note 2.34 db 8.4 µm See Note 2 Note 1: Note 2: Connector loss was calculated using Marcuse equations assuming same lateral offset to achieve 0.25 db for SMF to SMF splice with the typical MFD values given. Assume that both and with large pigtail-to-detector loss is equivalent to SMF pigtail-to-detector loss. Using SMF assemblies in with large based configurations results in an overall lower loss (1.28 db) than when using SMF assemblies in standard based configurations (1.36 db). The bottom line is that an all SMF pigtail/jumper configuration actually adds 0.31 db (typical) over a based configuration and 0.19 (typical) over a with large effective area based configuration. Although many new networks are being built with (G.655) fiber, Corning continues to recommend the use of SMF (G.652) fiber assemblies, patch cords and jumpers for all routes. The length of these assemblies typically is sufficiently short so that dispersion accumulation is negligible. Therefore, the use of SMF will not impact the transmission characteristics of the system. However, using NZ-DS fiber in the these assemblies induces an additional loss (as noted in Table 3 and Table 4), and managing assembly inventories for various fiber types adds unnecessary complexity. Given added system margin, lower cost and lower complexity, it is clear that SMF should continue to be the fiber of choice for assemblies. With attention to splicing practices and equipment set-up, and with large effective area offer the same ease of installation as standard single-mode fiber designs. System designers can feel confident that they can take advantage of all the benefits of the design in their high data rate systems and still achieve excellent splice performance. AN7078 Page 7 of 7