Parameterizing options. 8.1.1 Parameterization options based on the communication protocols used



Similar documents
I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP

Instructions. I.S. Wizard. for. I.S.1 field stations

GW-7552 PRIFIBUS/MODBUS GATEWAY

PROFINET IO Diagnostics 1

Device configurator DRC200

How to Program a Commander or Scout to Connect to Pilot Software

Lab - Configure a Windows 7 Firewall

Industrial IT Ó Melody Composer

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

How-To-Do. EtherCAT Communication with CPU 300S

Lab - Configure a Windows Vista Firewall

PCLaw Data Import Module

GE Healthcare Life Sciences UNICORN Administration and Technical Manual

TH SCOPE. Monitoring and Diagnostics of PROFINET, EtherNet/IP and Modbus TCP Networks. Installation Manual. Version: EN

TH SCOPE. Monitoring and Diagnostics of PROFINET, PROFIBUS, EtherNet/IP and Modbus TCP Networks. Installation Manual. Version: EN

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

28 What s New in IGSS V9. Speaker Notes INSIGHT AND OVERVIEW

Connecticut Hazardous Waste Manifests Database

BECKHOFF. Application Notes. BC9000: Getting Started Guide. For additional documentation, please visit.

Connecting to a Soundweb TM. London Network

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

First Time On-Campus Remote Desktop Connection ipad Edition

2010 Ing. Punzenberger COPA-DATA GmbH. All rights reserved.

The service note describes the basic steps to install a ip camera for the DVR670

Firewall Settings for AVG Free Edition

Welcome to MaxMobile. Introduction. System Requirements. MaxMobile 10.5 for Windows Mobile Pocket PC

RSView 32 ACTIVE DISPLAY SYSTEM GETTING RESULTS GUIDE. PUBLICATION VW32AD-GR001E-EN-E July 2011 Supersedes Publication VW32AD-GR001D-EN-E

Personalizing your Access Database with a Switchboard

How to read this guide

Instructions for transferring the SINUMERIK HMI to an external screen

EASE Scan Tool Customers. SECTION I - Installation

Setting up in Outlook Express

SIMATIC NET. DP Base Programming Interface for CP 5613/CP Preface, Contents. Basic Steps in Creating a DP Application 1

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

Global Monitoring + Support

TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer

Start-up of IVI-KHD2-4HRX, IVI-KHA6-4HRX at S7-300 V1.1. Table of Contents TABLE OF CONTENTS... 1

Important Notes for WinConnect Server VS Software Installation:

IGSS. Interactive Graphical SCADA System. Quick Start Guide

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

PowerLogic ION Enterprise 6.0

TECHNICAL TRAINING LAB INSTRUCTIONS

CLEARONE DOCUMENT (REVISION 1.0) October, with Converge Pro Units

How to make a diagnostic on TeSysT to start the network?

Do not start HiQnet London Architect on the computer until instructed to do so below at Start and Configure HiQnet London Architect.

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

Lab: Data Backup and Recovery in Windows XP

HART Demo Installation Guide

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

32 Transferring Projects and Data

ServerView Inventory Manager

Industrial IT. Compact Control Builder AC 800M Version 5.0. Getting Started Introduction and Installation

How To Write A Profibus Dpl (Profibus) Program

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

JUL / 07 VERSION 3.2

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

Volume. EverAccess. User s Manual

Service & Support. How do you configure time synchronization using the NTP procedure (without SICLOCK) for small PCS 7 plants?

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

WHAT IS VIRTUAL DESKTOP? WHAT YOU NEED LOG IN TO VIRTUAL DESKTOP SET UP CITRIX RECEIVER REMOTE ACCESS GUIDE

Change Management for Rational DOORS User s Guide

Robot CONSOLE 6 User Guide

Lecture Theatre. Introduction This document introduces users to basic system operation procedures using the touch screen.

GeoVision Setup. Once all the settings for Windows are completed and you have all the hard drives setup you can install GeoVision.

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES

PowerLogic ION Enterprise 5.6

Industrial IT. Compact Control Builder AC 800M Version 5.0 SP2. Getting Started Introduction and Installation

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Network Projector Operation Guide

Setting Up Monthly Reporter

Lab - Data Backup and Recovery in Windows XP

Manual Password Depot Server 8

Centurion C4 Transfer Guide using C4 File Transfer Utility

IndustrialIT System 800xA AC 870P/Melody Engineering

Configuring PROFINET

Working with SQL Server Integration Services

First Time Off-Campus Remote Desktop Connection ipad Edition

Adding a File Attachment to a CFS Requisition

VPN: Using WebVPN SSL Client This document outlines the process for using the WebVPN SSL with Internet Explorer and Firefox

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

LECTURE -08 INTRODUCTION TO PRIMAVERA PROJECT PLANNER (P6)

Compact Control Builder AC 800M

Robot SCHEDULE 12 User Guide

DP-313 Wireless Print Server

PC Agent Quick Start. Open the Agent. Autonomy Connected Backup. Version 8.8. Revision 0

Recommended KEPServerEX Settings for groov

In this lab you will explore the Windows XP Firewall and configure some advanced settings.

Changing Your Cameleon Server IP

SIMATIC PDM software. Siemens FI /1

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

COMSPHERE 6700 SERIES NETWORK MANAGEMENT SYSTEM

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

Monitoring ESX/ESXi servers with Verax NMS & APM

Transcription:

Setting module parameters 8 PARAMETERIZATION 8.1 Parameterizing options 8.1.1 Parameterization options based on the communication protocols used Many fieldbuses currently in use do not have sufficient performance for parameterization of the I.S. 1 system. For fieldbuses with low performance (example: ModBus), the ServiceBus must be used for parameterization. When using suitable fieldbuses (example: Profibus) the use of the ServiceBus for parameterization is not required. Parameterizing options The following parameterization options are possible for the I.S. 1 system: Via the display and operating interface of the CPU & Power Module (setting the fieldbus address) Via the ServiceBus Via various fieldbuses (e.g. with Profibus) with the aid of the GSD file Possible parameterization interfaces The parameterizing options are shown in Fig. 8-1: Fig. 8-1 Parameterization options via various interfaces R. STAHL SCHALTGERÄTE GMBH 8-1 I.S. 1 B 9400 Version 1.5 05/01

OPERATING INSTRUCTIONS FOR THE I.S. 1 SYSTEM 8.1.2 Performance of connectable fieldbuses Function Modbus Profibus DP ServiceBus Data transfer with a speed of 38 kbit/s 1.5 MBit/s 9.6 kbit/s Configure I.S. 1 No Yes Yes Load the modules with parameters Cyclically read/write input and output data Transfer alarm and diagnostic data No Yes Yes Yes Yes No Yes Yes Yes Transfer HART commands to/from HART field devices No In preparation Yes Read input data, set outputs (forced) for tests -- -- Yes Tab. 8-1 Functionality of connectable fieldbuses R. STAHL SCHALTGERÄTE GMBH 8-2 I.S. 1 B 9400 Version 1.5 05/01

Setting module parameters 8.2 Menu structure and operation of the input keys The fieldbus address is entered in the CPU & Power Module with the help of the display and the <up> and <down> keys. 8.2.1 Display and operating keys The operating panel of the CPU & Power Modules consists of two keys and a display (see Fig. 8-2). Both keys react differently to long or short pressure. Holding both keys down for a longer period initiates an additional functionality (<ENTER>). Fig. 8-2 Display and operating keys of the CPU & Power Module for Zone 1 (Type 9440/12) and for Zone 2 (Type 9440/15, at an opened cover) 1 Display 2 "Down" key 3 "Up" key R. STAHL SCHALTGERÄTE GMBH 8-3 I.S. 1 B 9400 Version 1.5 05/01

OPERATING INSTRUCTIONS FOR THE I.S. 1 SYSTEM 8.2.2 Function of operating keys Input <Up> key short press <Up> key long press <Down> key short press <Down> key long press <ENTER> Simultaneous <Up> and <Down> long press Function Modifies an input value or Modifies a menu item Automatic up Modifies an input value or Modifies a menu item Automatic down Calls up the selected function in the menu or Toggles from main view to menu Tab. 8-2 Function of the CPU & Power Module operating keys R. STAHL SCHALTGERÄTE GMBH 8-4 I.S. 1 B 9400 Version 1.5 05/01

Setting module parameters 8.2.3 Overview of menu items Menu items Display views Meaning "Startup" Initialization phase start... "Main view" FBAdr FB I/O Displays normal operation in delivery condition. For further information, see Chapter 8.2.4. --- off --- "Fieldbus address" CPM FBAdr --- The fieldbus address can be set using this menu. "Select" CPM FBAdr Setting the number for the fieldbus address. select: 5 "Accept" Saving or rejecting the set fieldbus address. accept changes? yes "Back" Return to main view. CPM back Tab. 8-3 Menu items and a selection of the relevant display views R. STAHL SCHALTGERÄTE GMBH 8-5 I.S. 1 B 9400 Version 1.5 05/01

OPERATING INSTRUCTIONS FOR THE I.S. 1 SYSTEM 8.2.4 Main view The main view shows an overview of the various information regarding the system: Fieldbus address Communication at the fieldbus Status of the I/O modules The diagram shows the main view without a set fieldbus address: FBAdr FB I/O --- off --- The status displays here indicate: Fieldbus address not yet set (---) No connection to fieldbus (off) I/O modules are not cyclically addressed If no fieldbus address has been set, the configured address must be input. This is the case after the first start-up. Use <ENTER> to go directly to the menu where the fieldbus address can be set (see Chapter 8.3). 8.2.5 Menu when fieldbus address is first set The display messages are divided into: Power Up (start-up) Normal operation (main view) Input of fieldbus address If the fieldbus address is modified, the modifications are confirmed by the query <accept changes yes/no>. R. STAHL SCHALTGERÄTE GMBH 8-6 I.S. 1 B 9400 Version 1.5 05/01

Setting module parameters Navigation structure The navigation structure for setting the fieldbus address is shown in Fig. 8-3: No information is indicated on the display before the power supply has been switched on (see navigation structure, first display (1)). After it has been switched off, the initialization phase of the CPU & Power Module starts. The "start " message is indicated on the display (see navigation structure, second display (2)). The display changes to the subsequent displays when the keys <ENTER>, <up> or <down> are pressed. This change is represented in Fig. 8-3 by arrows. Fig. 8-3 Navigation structure of the CPU & Power Module software 1 Display in switched-off state 2 Display after the power supply has been switched on, initialization phase R. STAHL SCHALTGERÄTE GMBH 8-7 I.S. 1 B 9400 Version 1.5 05/01

OPERATING INSTRUCTIONS FOR THE I.S. 1 SYSTEM 8.3 Setting the fieldbus addresses on the CPU & Power Module The fieldbus addresses can only be changed when the fieldbus is inactive or disconnected. In this case "FB off" is displayed. Menu "Fieldbus address" Starting from the main view (see Chapter 8.2.4) switch to the menu "Fieldbus address": Press <ENTER>. The display switches from the main view to the menu "Fieldbus address". One of the three screenshots shown in Tab. 8-4 will appear on the display: Display views in the menu "Fieldbus address" CPM FBAdr --- Meaning CPM ready to accept the new fieldbus address. Fieldbus address not yet input (delivery state from factory). CPM FBAdr 0 CPM ready to accept the new fieldbus address. In this example the fieldbus address is "0". Tab. 8-4 Display views in the menu "Fieldbus status" R. STAHL SCHALTGERÄTE GMBH 8-8 I.S. 1 B 9400 Version 1.5 05/01

Setting module parameters Menu "Select" To switch from the menu "Fieldbus address" (see Tab. 8-4) to the display "Select": Press <ENTER>. If the fieldbus is inactive or not connected, the menu jumps to the "Select" display. The display shows: CPM FB Adr select: 0 Address setting The fieldbus address can be set by pressing the keys <up> or <down> briefly. Short presses increase or decrease the address by 1. Long presses automatically increase or decrease the address. To increase the value, press the key <up>. The number is shown on the display. To decrease the value, press the key <down>. The number is shown on the display. When the required number is reached: Press <ENTER>. The corresponding number is assigned to the fieldbus address and temporarily stored. The menu changes to the "Accept" display. The display shows: accept changes? yes R. STAHL SCHALTGERÄTE GMBH 8-9 I.S. 1 B 9400 Version 1.5 05/01

OPERATING INSTRUCTIONS FOR THE I.S. 1 SYSTEM Saving the address If the address is to be saved: Press <ENTER>. The CPU & Power Module starts up again. After the start-up the main window is displayed with the field address which has been set. If the fieldbus is active (FB OK), the CPM is not ready to accept a new fieldbus address. The display shows: The fieldbus must be deactivated in order to enter a new fieldbus address. Canceling the address modification If the address is not to be saved: Press the <down> key. The display shows: accept changes? no Press <ENTER>. The newly set address will not be saved. The display then shows "---" or the previously set address. R. STAHL SCHALTGERÄTE GMBH 8-10 I.S. 1 B 9400 Version 1.5 05/01

Setting module parameters 8.4 Parameterization via the ServiceBus The software package "I.S. Wizard" by R. STAHL offers the user many options for rapidly and simply operating and maintaining I.S. 1 systems and field stations. The ServiceBus can be used to: Configure field stations Read back configurations Parameterize the CPU & Power Module and I/O modules Read inputs, write outputs Read and interpret diagnostic data for the three levels: - Field station - Module - Signals Read information (e.g. module type, module revision) 8.4.1 Advantages of the PC Software "I.S. Wizard" Simulation A complete test of a field station can be carried out without a functioning fieldbus. "I.S. Wizard" can be operated at the ServiceBus simultaneously with the fieldbus (reading access). Existing systems can be integrated "I.S. Wizard" permits operation of I.S. 1 field stations together with VOS 200 field stations on a ServiceBus so that even existing VOS 200 systems can be extended with I.S. 1 stations. ActiveX Open interfaces with OPC (OLE for process control) and ActiveX permit the integration of I.S. Wizard in control systems or Office applications. Default values The CPU & Power Module and I/O modules already have suitable default settings for all parameters. However, the parameters can be modified via the ServiceBus using a laptop or PC. R. STAHL SCHALTGERÄTE GMBH 8-11 I.S. 1 B 9400 Version 1.5 05/01

OPERATING INSTRUCTIONS FOR THE I.S. 1 SYSTEM 8.4.2 Controllability of modules and signals A detailed description of the software can be found in the I.S. Wizard operating instructions. Individual field stations and modules can be clicked on in the structure tree (Fig. 8-4) down to the signal level. Clicking on a module icon opens an input form where the module data can be entered. Fig. 8-4 Representation of each individual module using the software "I.S. Wizard" Additional functions In addition, the "I.S. Wizard" software provides the following functions: Creating new projects Activating/deactivating signals Modifying and setting parameters Printing out the system configuration Printing out labels for the modules R. STAHL SCHALTGERÄTE GMBH 8-12 I.S. 1 B 9400 Version 1.5 05/01

Setting module parameters 8.5 Configuration and parameterization of field stations via Profibus Complete descriptions of the configuration and parameterization options can be found in the operating instructions "Profibus DP for I.S. 1". The Profibus is a very high performance fieldbus. Because of the high performance of the Profibus, the I.S. 1 field stations connected to the Profibus can be configured and module-specific parameters set via the Profibus master. The necessary data for this is contained in the GSD file. The precise steps for parameterizing the system depend on the field-busspecific software used. 8.5.1 Requirements The following components must be available for the configuration and parameterization of a fieldbus via the Profibus: Configuration software for Profibus master Profibus master GSD file (electronic data sheet of the I.S. 1 station) If the field station is to be parameterized via the fieldbus interface, the fieldbus address must first be set on the CPU & Power Module. See Chapter 8.3. 8.5.2 Intended condition of the I.S. 1 system after completing configuration and parameterization The following criteria must be met after completion of configuration and parameterization: All data (configuration, parameters) of the field stations, modules and signals are acquired by the configuration software. The I.S. 1 system is not yet started, no data exchange is taking place. When the Profibus is started-up, the configuration data and parameters are transferred from the Profibus master to the field stations and checked. Only then will the cyclical data exchange for inputs and outputs begin. R. STAHL SCHALTGERÄTE GMBH 8-13 I.S. 1 B 9400 Version 1.5 05/01

OPERATING INSTRUCTIONS FOR THE I.S. 1 SYSTEM R. STAHL SCHALTGERÄTE GMBH 8-14 I.S. 1 B 9400 Version 1.5 05/01