LAYERED GREEN ROOF DETAILS LGR1.01 LGR1.02 LGR1.03 LGR2.01 LGR2.02 LGR2.03 LGR3.01 LGR3.02 LGR3.02 LGR4.01 LGR5.01 LGR5.02 LGR5.03 LGR5.04 LGR5.05 LGR6.01 [A-D] EXTENSIVE GREEN ROOF [A-C] SEMI-INTENSIVE GREEN ROOF [A-B] INTENSIVE GREEN ROOF SEDUM TILE/MAT SEDUM PLUG SEDUM CUTTINGS PEDESTAL PAVER VEGETATION FREE ZONE BALLAST ROCK VEGETATION FREE ZONE PAVER OVER BALLAST ROCK VEGETATION FREE ZONE WALKWAY- PAVER OVER BALLAST ROCK 4.5" METAL EDGING 4.5" METAL EDGING 5.5" METAL EDGING 5.5" METAL EDGING 8.5" METAL EDGING IRRIGATION TPG0.00 LAYERED GREEN ROOF DETAILS LAYERED SYSTEM DETAIL SCALE: 2"=1'-0" ISSUE DATE: 04/03/2014
3/8" 1" 3" 3" EXTENSIVE LAYERED GREEN ROOF LAYERED SYSTEM DETAIL SCALE: 3"=1'-0" ISSUE DATE: 04/03/2014
3/8" 1" 4" 4" EXTENSIVE LAYERED GREEN ROOF LAYERED SYSTEM DETAIL SCALE: 3"=1'-0" ISSUE DATE: 04/03/2014
3/8" 1" 5" 5" EXTENSIVE LAYERED GREEN ROOF LAYERED SYSTEM DETAIL SCALE: 3"=1'-0" ISSUE DATE: 04/03/2014
3/8" 1" 6" 6" EXTENSIVE LAYERED GREEN ROOF LAYERED SYSTEM DETAIL SCALE: 3"=1'-0" ISSUE DATE: 04/03/2014
3/4" 5/8" 5" 5" SEMI-INTENSIVE LAYERED GREEN ROOF LAYERED SYSTEM DETAIL SCALE: 3"=1'-0" ISSUE DATE: 04/03/2014
3/4" 5/8" 6" 6" SEMI-INTENSIVE LAYERED GREEN ROOF LAYERED SYSTEM DETAIL SCALE: 3"=1'-0" ISSUE DATE: 04/03/2014
3/4" 5/8" 8" 8" SEMI-INTENSIVE LAYERED GREEN ROOF
1 1/2" 5/8" VARIES; 8" + INTENSIVE LAYERED GREEN ROOF LAYERED SYSTEM DETAIL SCALE: 3"=1'-0" ISSUE DATE: 04/03/2014
1 1/2" VARIES; 8" + INTENSIVE LAYERED GREEN ROOF
+/- 1 2" PLANTING METHOD: SEDUM TILE/MAT
TRI-SPACED; X" O.C. PLANTING METHOD: SEDUM PLUGS
PLANTING METHOD: SEDUM CUTTINGS
VARIES VEGETATION FREE ZONE: PEDESTAL PAVER
VARIES BETWEEN 12-24" WALL SKIRTING BY OTHERS ROOF MEMBRANE ATTACHED PER MFGS. SPECIFICATIONS FASTEN AT 6" O.C. BALLAST ANCHOR FLASHING METAL EDGING WASHED BALLAST ROCK. SIZE AND DEPTH TO BE DETERMINED BY WIND LIFT REQUIREMENTS. SEE STRUCTURAL SPECIFICATIONS. WATER RETENTION LAYER FILTRATION LAYER DRAINAGE LAYER ROOT BARRIER LAYER ROOF MEMBRANE VEGETATION FREE ZONE: ROCK BALLAST
VARIES BETWEEN 12-24" WALL SKIRTING BY OTHERS ROOF MEMBRANE ATTACHED PER MFGS. SPECIFICATIONS FASTEN AT 6" O.C. ANCHOR FLASHING ROOFING PAVER METAL EDGING WASHED BALLAST ROCK. SIZE AND DEPTH TO BE DETERMINED BY WIND LIFT REQUIREMENTS. SEE STRUCTURAL SPECIFICATIONS. WATER RETENTION LAYER FILTRATION LAYER DRAINAGE LAYER ROOT BARRIER LAYER ROOF MEMBRANE VEGETATION FREE ZONE: PAVERS
VARIES BETWEEN 12-24" ROOFING PAVER EDGING BALLAST ROCK ROOF MEMBRANE WALKWAY: PAVER OVER BALLAST ROCK
ADJACENT CONDITION VARIES 4 1/2" 3" 3 1/4" METAL EDGER- 4.5" X 3.25"
ADJACENT CONDITION VARIES 8" TAPER TO TOP OF EDGER 4 1/2" 4" 3 1/4" METAL EDGER: 4.5" X 3.25"
ADJACENT CONDITION VARIES 8" TAPER TO TOP OF EDGER 5 1/2" 5" 6 1/2" METAL EDGER: 5.5" X 6.5"
ADJACENT CONDITION VARIES 12" TAPER TO TOP OF EDGER 5 1/2" 6" 6 1/2" METAL EDGER: 5.5" X 6.5"
ADJACENT CONDITION VARIES TAPER TO TOP OF EDGER 8 1/2" 8"+ 7 1/2" METAL EDGER: 8.5" X 7.5"
HEAD SPACING VARIES. SEE IRRIGATION PLAN SPRAY NOZZLE, BY OTHERS. [HUNTER MP ROTATOR ROTARY NOZZLE] 2" MIN. 1/2" FEMALE THREADED TO SPRAY NOZZLE ADAPTER 1/2" SCHEDULE 80 MALE TO MALE THREADED NIPPLE SLIP TO SLIP TO FEMALE THREADED "T" PVC IRRIGATION LATERAL WATER RETENTION LAYER FILTRATION LAYER DRAINAGE LAYER GROWING MEDIA SEE LGR1.0X FOR LAYERED SYSTEM SPECIFICATIONS ROOF MEMBRANE SPRAY IRRIGATION