Options and monitoring

Similar documents
UPS Management Software

UPS MANAGEMENT SOFTWARE

UPS MANAGEMENT SOFTWARE OPTIONS

Description UPS Management Software

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

PowerGem Pro Uninterruptible Power Supply

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

Phase Modular Finally the benefits of Modular ups are for all

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

LAP ENERGIA PARA DATACENTERS

UPS-Management Software

Communication and connectivity the ideal solution for integrated system management and data integrity

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Sentry Bulldog Shutdown Management Software (For UNIX Series)

UPS-Management Software

UPS-Management Software

VISION UPS UPS PRODUCT CATALOGUE

Uninterruptible Power Supply

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

Remote Monitoring and REC 501 Control Unit Product Guide

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

MONITORING. m 3 /s. m/s F Pa. g/m 3. Software. Data Input. M2M Transfer. Processing. XML/HTTP SNMP, GPRS/SMS. Measurement Sensors Dry contacts

Solutions for E-Mobility

The UPS for the highest security in industry and data centres

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

SECTION DETECTION AND ALARM

UPS-Management Software

Doc 10. UTM Standards: Card Access Security System

SentryPlus. Shutdown Management Software for Windows. User s Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

Electric mobility: The small charging in between Safe charging with the right charging cable for mode 2

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

UPS Communicator. UPS Communicator English Manual Release

Configurable Events for APC Network Management Card

TOSHIBA G /100/160/225 kva

OVERVIEW OF THE TELEGUARD HOME SECURITY SYSTEM

UNINTERRUPTIBLE POWER SUPPLY (UPS)

User Manual 1K/2K/3K Online UPS

Executive Summary. Technical Description

Technical Data. back-up time in minutes 100% load % load

User Manual WatchPower

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

Data Logger & Net Client Software (Windows, ipad, Android) Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment!

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

S100. GSM House Alarm System.

Web Based Environment Monitor and Control System

The Business case for monitoring points... PCM architecture...

GSM HOME SECURITY SYSTEM

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

SENSAPHONE 901 Tryens Road Aston, PA PH:

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

4.0 UPS dedicated to ICT for unmatched energy savings

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

Power & Environmental Monitoring

minova technology electronics

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Smart-UPS On-Line 230 V

ZigBee Wireless Sensor Networks

Poseidon MANUAL

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

sat-nms SMU Signal Management Unit

QUICK PROBLEM SOLVING GUIDE

Access Control and Operating Conditions Monitoring System for Telecommunication and Server Racks

Schneider Electric GALAXY VM Data Center Grade Three Phase Uninterruptible Power Supply Guide Specifications kva UPS

USER MANUAL Online UPS 1K/2K/3K Rack

Frequency selective monitoring and logging of environmental electromagnetic fields

NGSS Data Consolidator (DC)

PowerCommand iwatch 100 Remote Network Monitoring

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

GSM Voice Auto Dialer & SMS Sender JC-999

Business/ Home GSM Alarm System

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

OPTIONAL FEATURES 30

TLE Series. Product Description kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR

securityprobe 5E Standard

Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course Tripp Lite.

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Continuous, remote monitoring and logging of electromagnetic fields

NEW. EVEN MORE data acquisition and test stand automation

GSM ALARM SYSTEM USER MANUAL

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

AutoLog ControlMan Success Story Remote monitoring of district heating system as Cloud Service

TSX ETY 110 Module 8

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Power Management of Cell Sites

WiFi Edition

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Transcription:

Additional outlets Energy distribution unit with two Schuko-outlets and four IEC-outlets. Rackmount module version with a height of 2 units. Parallel Distribution Box with Bypasss A compact distribution box which allows parallel connection of up to four UPS to increase the power and reliability of the system. UPS can be added in a very simple way. The box also has an external bypass module inside, which provides power supply to the load even if the UPS is disconnected for maintenance. Remote control panel The remote control panel is physically connected with the UPS (by cable) and allows distant monitoring and management of the system. The panel can be installed as far as 500m from the UPS and will be power supplied by the interface cable. NetFeeler Temperature/Humidity/Water sensor Wireless smoke sensor Magnetic contact sensor The sensors are connected to the three-port-snmp-adapter, offered by VISION UPS. They are mostly used in server cabinets and for the observation of buildings. Very easy installation and adjustment. Split-Bypass Alternative input for the UPS which allows the use of an additional power source, which works independently from the first power source (for example mains and diesel genset). Additional chargers (internal/external) For batteries of higher capacity and faster time of recharge

Galvanic isolation transformer The high-quality online UPS of VISION can be provided with a galvanic isolation transformer, which means that the electric circuits before and after the UPS are not connected physically, but via an electromagnetiс field. This increases the reliability of the protection essentially. Spikes and disturbances can not pass the galvanic isolation transformer. External Bypass External manual bypass modules allow service and maintenance work without interruption of the power supply. The UPS can be disconnected after the power supply was switched to the bypass line. Web/SNMP-Adapter SNMP-Adapters provide monitoring of the UPS via Ethernet. The monitoring software allows connection with one or more UPS by means of the individual IP-adress every UPS gets. Monitoring and control can be made distantly. For example all servers in a network can be shutdown. Afterwards all servers can be started up by Wake-up-on-LAN. SMS can be sent without LAN-connection by using a GSM Modem. Relay card / AS400 / Modbus Relay cards are based on dry contacts and give signals in the case of power supply interruption, switching to bypass or general faults. The AS400 and ModBus card provide the interface for the corresponding protocols. IEC to Schuko converter with 3 outlets For additional Schuko outlets

UPS Management-software by VISION The UPS-Management Software is a client/server application for networks and local workstations. The UPS-Management Software is connected with the UPS by RS-232/485/USB cable. The software collects the messages sent from the UPS as a background program. If the software detects voltage variations or a power loss it can execute different system event routines, which, for example, may shutdown the server or send warnings to connected users. These system event routines, which are part of the UPS-Management Software, are fully customisable. You can program UPS-Routines (e.g. define dates for automatic UPS-tests, shutdown the system at defined dates, etc.), check the status of the UPS, execute different UPS tests or create power quality statistics. You can also constantly monitor and evaluate the event protocol (log file) that is permanently updated. It is also possible to provide a simultaneous shutdown of several servers that are all supported by the same UPS. - Low battery warning, on-screen backup time, battery time countdown, Low battery warning, UPS temperature such as battery and internal temperature, defect battery warning, time and date stamp event logging, extensive logging of all UPS activity and user messaging. - Battery management, surveillance and counter for power events. - SMTP compatible system with messaging service for E-mail, E-mail to SMS or other external services. - Client/server software for heterogeneous networks with one and three-phased UPS. - "Look & feel" is identical on all platforms. - Integrated SNMP agent for NetWare, MS -WINDOWS NT/2000, Linux and SUN - Supports all important network protocols for the graphical control of the UPS from every Windows Station in the network. - Automatic unattended shutdown of local and remote computers in networks (Master/Slave via RCCMD module) - Selftest functions, such as economy mode, UPS temperature, battery load, power socket switching and UPS emergency cut-off. - Shutdown and test functions can be executed with a Scheduler - Graphic display of quality of incoming power load frequency in minimum-maximum or average values. Software made by Generex and MegaTec.

1. For all UPS (also for the Premium-Series) VISION UPS SNMP-Adapters SNMP and Software by MEGATEC (Taiwan) Internal one-port-snmp card Internal three-port-snmp card External one-port-snmp adapter External three-port-snmp adapter NetFeeler: Temperature/Humidity sensor (requires three-port-snmp-adapter) Wireless Smoke Detector (requires NetFeeler) Door/window magnetic contact sensor (requires NetFeeler) GSM-Adapter for SMS Door/window magnetic contact sensor (requires three-port-snmp-adapter) V I S I O N U P S S Y S T E M S S à r l - Duarrefstrooss 36, 9944 Beiler, Grand Duchy of Luxembourg Tel: +352 269 589 20 / Fax: +352 269 589 30 / info@visionups.com

2. Only for the PREMIUM-Series (Premium DSP, Premium DSP+/++, Premium 33+) SNMP and Software by GENEREX (Germany) Internal SNMP (CS121 Budget) External SNMP (CS121 Budget) Extra: CS121 Professional with extended functions V I S I O N U P S S Y S T E M S S à r l - Duarrefstrooss 36, 9944 Beiler, Grand Duchy of Luxembourg Tel: +352 269 589 20 / Fax: +352 269 589 30 / info@visionups.com