DUCT SMOKE DETECTOR D4120



Similar documents
Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

E-PDD Duct Smoke Detector Installation Sheet

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

D4120 Duct Smoke Detector D4S Sensor Component D4P120 Power Board Component

D4120 Duct Smoke Detector D4S Sensor Component D4P120 Power Board Component

DH100ACDCLWP Watertight Air Duct Smoke Detector with Extended Air Speed Range

Smoke Detector PSD 2 & 4 Wire Units

D287/D288/D292/D293A/D293E

Fire & Security DETECTORS

Electronic Control Devices The European Product Catalogue 2007

FIRE DAMPER APPLICATION GUIDE

HM-W536 Install Guide

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Fire Alarm System Accessories

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

8900 EMR (WITH DETECTOR)

AMD-33 Air Measuring Station with VCD-33 Control Damper

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

INSTALLATION AND MAINTENANCE INSTRUCTIONS I R

8146/5 Series Breaker Panelboards

TS93 EMR T/PT/TDE. Surface applied door closer

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

WD-AMX Water Detection Controllers

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

Buckeye Detection Systems Fixed Detection Systems Application Survey

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

How To Read A Pipe From A Sensor

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

NFPA Edition Fire dampers shall be permitted to be installed in exhaust systems in the following situations:

T7560A,B,C Digital Wall Module

Manual for Fire Suppression & Methane Detection System

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

BERMAD Fire Protection

Duct Humidity Transmitter

650W Single Output Power Supply

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Water Leak Detection System

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

WE-350 Series ¼ Turn Electric Actuator

TMS TANK MANAGEMENT SYSTEM

Advantium 2 Plus Alarm

Advanced Intelligent Modules. Overview. Description

rpsa FIRE PROTECTION ENGINEERS

Via dell' Industria, S. Vendemiano (TV) Tel Fax Acquisti@elettrolab.

EMF/EMR. Holder/Release Devices with Integral Door Closers

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

SECTION DETECTION AND ALARM

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

HMI display Installation Guide

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

Electronic Control Devices The European Product Catalogue 2007

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Universal Voltage Terminal Photoelectric E3JM

AZ420 MINIATURE GENERAL PURPOSE RELAY

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

SMART SENSOR COLLECTION

Pressure Switch for gas and air

Intersection Preassembled 19-inch Rack

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

ENGINEERING SPECIFICATIONS

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

INSTALLATION INSTRUCTIONS

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

E2 Series Electric Furnaces

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

AXIS PS12 Outdoor Power Supply. Installation Guide

Electronic, Digital and Mechanical Vibration Switches

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

VIBRATION SWITCHES SOLID STATE

FIREDEX Conventional Fire Panels

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

TrueAlarm Fire Alarm Systems

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Transcription:

Purpose/Application National and local safety standards and codes recognize the ability of air duct systems to transfer smoke, toxic gases, and flame from area to area. Sometimes smoke can be of such quantity as to be a serious hazard to life safety unless blowers are shut down and dampers are actuated. The primary purpose of duct smoke detection is to prevent injury, panic, and property damage by reducing the spread (recirculation) of smoke. The detector samples air currents passing through a duct and gives dependable performance for management of smoke and combination fire smoke dampers. Duct smoke detection can also serve to protect the air conditioning system itself from fire and smoke damage. There are several important documents that provide guidance concerning the performance, application and installation of duct detectors: 1) NFPA Standard 90A, Installation of Air Conditioning and Ventilating Systems 2) NFPA Standard 92A, Recommended Practice for Smoke Control Systems 3) NFPA Standard 72, National Fire Alarm Code 4) NFPA Standard 101, Life Safety Code 5) UL Standard 268A, Standard for Smoke Detectors for Duct Applications 6) System Sensor, Application Guide System Smoke Detectors & Duct Application Smoke Detectors Duct detectors are: NOT a substitute for an open area smoke detector. NOT a substitute for early warning detection, and NOT a replacement for a building s regular fire detection system. Specifications Type: Photoelectric Air duct velocity: 100 to 4000 fpm (.5 m/s to 20.3 m/s) Operating temperature range: -4 F to 158 F (-20 C to 70 C) Operating humidity range: 0% to 95% R.H. Operation Voltage: 24 VAC/DC or 120 VAC Dimensions: 14.38 in. L x 5 in. W x 2.5 in. H (365mm x 127mm x 63.5mm) Features Improved cover design isolates the sensor head from the low flow feature for easier maintenance Plug is sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. Up to 50 detectors may be interconnected. Terminal connections are of the strip and clamp method suitable for 12-18 AWG wiring. Easy access test /reset button makes it possible to test the unit with the cover on. The housing provides ample wiring space, 3/4 in. conduit knockout and built-in short circuit protection to prevent damage to sensitive components during installation. DUCT SMOKE DETECTOR D4120 Configuration Maximum wall thickness: 6 in. (152mm) on FSD & SSFSD applications (Consult factory for walls greater than 6 in. [152mm]) Actuator Location: Must be right hand drive Must be externally mounted Detector Location: Mounts opposite actuator side Must be external Sampling tubes longer than three feet must be supported on each end. Holes in duct smoke detector sampling tubes must face into the airflow. Availability For use with all FSD, SSFSD, SMD, SSSMD, and CFSD models. Not available on SMDR models. Listings UL 268A Refer to Greenheck Installation Supplement: Part #463813 IOM-Smoke Detector Supplement

Sleeve Length Ordering Options Sleeve Length Height less than 25 in. (635mm): 24 in. (610mm) sleeve (15 in. [381mm] A dimension) (detector mounted parallel to sleeve) Height greater than or equal to 25 in. (635mm): 21 in. (533mm) sleeve (11 in. [279mm] A dimension) (detector mounted perpendicular to sleeve) 1 1 2 in. x 1 1 2 in. 16 ga. minimum r etaining angl e Figure 1: Label applied to dampers with factory mounted duct smoke detectors. Smoke detector r equir es 100 fpm minimum air velocity in duct. For damper activation r equir ements when system velocity is less than 100 fpm, the local authority having jurisdiction should be consulted. Refer to smoke detector installation instructions and Gr eenheck IOM - Smoke Detector Supplement FS for dampers with factory mounted duct smoke detectors. 458565 1 1 2 in. x 1 1 2 in. 16 ga. minimum r etaining angl e Accessory (OCI/RRL/TOR) mounted exter nally on righthand side of damper Duct Breakaway Connection (by others) 1 1 2 in. x 1 1 2 in. 16 ga. minimum retaining angle Smoke detector mounted externally on left-hand side of damper 1 1 2 in. x 1 1 2 in. 16 ga. minimum retaining angle Height equal to or gr eater than 25 inches Height less than 25 inches Smoke detector mounted exter nally on left-hand side of damper Note: All actuators will be exter nally mounted on the right-hand side of damper Accessory (OCI/RRL/TOR) mounted externally on righthand side of damper Duct Br eakaway Connection (by others) Note: All actuators will be externally mounted on the right-hand side of damper 15 in. A dimension 6 in. wall maximum 24 in. sleeve length 3 in. minimum to allow for retaining angle and duct breakaway connection 11 in. A dimension 6 in. wal l maximum 21 in. sleeve length 3 in. minimum to allow for r etaining angle and duct br eakaway connection Figure 2: Smoke detector mounting orientation for dampers less than 25 inches (635mm) in height. Ordering Options Factory Mounted Smoke detector will be wired to a 4 in. x 4 in. (102mm x 102mm) handi-box. The closure device (if RRL or TOR) will also be wired to the handi-box. Dampers provided with the smoke detector option will include single point wiring as standard (includes RRL, OCI, TOR, detectors, and multiple actuators). Shipped Loose Shipped loose smoke detector will only include the detector itself (no mounting hardware or bracket seals). The duct size will have to be specified in order to allocate the appropriate length sampling tube. Adhere to all national and local codes. Figure 3: Smoke detector mounting orientation for dampers equal to or greater than 25 inches (635mm) in height. IMPORTANT! Dampers ordered with shipped loose smoke detectors will have the standard sleeve length, not a longer sleeve to accommodate the smoke detector installation. If smoke detectors are intended to be field mounted on the damper sleeve, the damper sleeve length and A dimension will need to be manually changed to the requirements indicated under Sleeve Length.

Space Envelopes Dampers Less Than 25 Inches (635mm) In Height Electrical Ratings 3 in. Typical Actuator (ML-4115 shown; other actuators available) 6 3 4 in. 2 3/4 in. (70mm) Single Point Wiring (Standard) Smoke detector, actuator, and all control options are prewired to junction box at the factory. Dampers Equal To Or Greater Than 25 Inches (635mm) In Height Typical Actuator (other actuators available) 15 in. (381mm) Single Point Wiring (Standard): Smoke detector, actuator, and all control optiong are prewired to junction box at the factory. Electrical Ratings Power Supply Voltage 20-29 VDC 24 VAC 50-60Hz 120 VAC 50-60 Hz Input Capacitance 270 µf max. 270 µf max. N/A Reset Voltage 3.0 VDC min. 2.0 VAC min 10 VAC min Reset Time 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power Up Time 35 sec. max. 35 sec. max. 35 sec. max. Alarm Response Time 15 sec. 15 sec. 15 sec. Sensitivity Test See detector label See detector label See detector label Current Requirements Max. Standby Current 21 ma 65 ma RMS @ 24 VAC 60 Hz Max. Alarm Current 65 ma 135 ma RMS @ 24 VAC 60 Hz 20 ma@120 VAC 60 Hz 35 ma @ 120 VAC 60 Hz Contact Ratings Alarm Initiation Contacts (SPST): 2.0A @ 30 VDC (resistive) Alarm Auxiliary Contacts (DPDT): 10A @ 30 VDC (resistive) 10A @ 250 VDC (resistive) Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. Supervisory Contacts (SPDT): 2.0A @ 30 VDC (resistive)

Fusible Link OCI

RRL RRL/OCI

TOR OCI w/ EP Switch

RRL W/ EP Switch RRL/OCI W/ EP Switch

TOR w/ EP Switch Copyright 2010 Greenheck Fan Corporation D4120 Smoke Detector Rev. 2 Sept 2010