Perimeter Security System



Similar documents
INTREPID Perimeter Intrusion Detection System

INTREPID Buried Cable Perimeter Intrusion Detection System

INTEGRATED PERIMETER SECURITY SOLUTIONS FENCE DETECTION SYSTEMS BURIED CABLE DETECTION SYSTEMS ALARM MONITORING AND CONTROL SYSTEMS MICROWAVE SENSORS

The Premier Fence Mounted Perimeter Intruder Detection System

Architectural and Engineering Specification for a Perimeter Intrusion Detection System. FiberPatrol-ZR

LB Sky Global. 92 Lobachevskogo St, Bld 92, Office 5, Moscow, Russia Tel/Fax 7(495) , Site:

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Architectural and Engineering Specification for a Perimeter Intrusion Detection and Pipeline Third-Party Interference (TPI) Detection System

Why secure PV fields. Why choose a fence-mounted intrusion detection system

Regards from the Team at Rheology Solutions.

EQUIPMENT SPECIFICATIONS

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Optical fiber intrusion detection fence sensor

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Operating Instructions

Advanced Fencing and Security Technologies Ltd

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

WIRELESS INSTRUMENTATION TECHNOLOGY

Triple Waveband Infra-Red Flame Detection

Introducing TransitVUE Perimeter IDS, the most advanced perimeter intrusion detection system available today! Protecting Perimeters Around the World

PowerCode Wireless. Fully supervised wireless system. Features

Infinity 2020 Perimeter Intrusion Detection System

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

DTW Works Master Specification Version 2006

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

SC100 Series Seismic Vibration Sensors. The Best Way to Protect High-Risk Commercial Assets

Current Monitoring Kit QUICK START GUIDE

SingleNet Single Cable Control System

Unidirectional Transmitter/ Receiver Units Introduction

D287/D288/D292/D293A/D293E

Alliance System Ordering Guide

Current Monitoring Kit

Ordering Part Numbers:

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Interceptor Optical Network Security System. Design Guide. Chapter 4: INTERCEPTOR Optical Network Security System Alarmed Carrier PDS

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

1.44 kw Programmable DC Power Supplies XLN Series

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

SMART SENSOR COLLECTION

NETWORK ENABLED EQUIPMENT MONITOR

Everything you need for protection scheme testing

with Electronic Assistant

O C M III. Open Channel Flow Monitor

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Current Loop Application Note 1495

EZ-H Owner s Manual. Integrated HDMI over Fiber Optic Cable

INTRUSION ALARM SYSTEM

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

F2400 FOM II Series Fiber Optic Modem Technical Manual

Utilizing Furukawa Optical Fiber Technology. Optical Fiber Sensing System

Microphonic Cable Fence Disturbance Sensor (multiplex version)

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

WD-AMX Water Detection Controllers

ACCESS CONTROL SYSTEM

Security Systems Intrusion Alarm

INTERFACING SECURITY SYSTEMS TO HOMEVISION

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

USER MANUAL V5.0 ST100

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Advantium 2 Plus Alarm

FIBER SECURITY. Optical Fiber Perimeter Intrusion Detection System

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

WORLDWIDE. GW400k SERIES MAINTENANCE MANUAL PROVEN PERIMETER PROTECTION

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Operating Instructions

Electronic Control Devices The European Product Catalogue 2007

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

How to Solve the Most Persistent Problem in Perimeter Security Systems

Intrusion Outdoor Protection Perimeter

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

Process Alarm Solutions

Always on the Lookout Perfect Protection against Burglary

Product Information Fire alarm panel 8000 C

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

WEB log. Device connection plans

NOVA MULTI-MONITORING SOFTWARE. Instruction Manual

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

ALARMLINE ANALOGUE Linear Heat Detection System

SMS GSM Alarm Messenger

PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS

SKY LIGHT INTERSECTION SYSTEM

Product Specification instalert Rapid Messenger Variable Message Sign

Transcription:

TM Perimeter Security System The Next Generation Perimeter Security System ICRONET combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience. It is a sophisticated perimeter security system which provides precise location of alarms. MICRONET is based on MicroPoint cable technology which detects any fence disturbance and locates it to within 10 feet. Precise location allows proprietary digital signal processing (DSP) algorithms to detect any attempt to cut or climb the fence while ignoring distributed noise from wind, rain or heavy vehicles. Reliable detection is assured. MICRONET also transmits alarm signals and operating power to all MICRONET modules and auxiliary sensors along the perimeter eliminating the need for extra wiring. MICRONET software interfaces directly with a personal computer (PC) so that your computer becomes the installation test set, graphic map, and alarm monitoring display. Installed cost is very low! Best of all, MICRONET was designed by Southwest Microwave, and it is backed by our 30 years experience with exterior security systems Features: MicroPoint Detection with location to 10 feet Sensitivity Leveling for varying fence conditions Free Format Zoning eliminates hardware constraints in system design Point Impact Discrimination increases detection without increasing nuisance alarms MicroPoint cable with integrated power and data for reduced installation costs Windows based PC installation around the world.

TM Perimeter Security Systems System Description MICRONET MicroPoint cable is tie wrapped to a chain link fence where it detects vibrations from any cut or climb and precisely locates the point of intrusion. MicroPoint cable transmits alarm data and system status to each MICRONET module and provides power to these modules and auxiliary sensors along the perimeter. No other equipment or wiring is needed. Precise location of each fence disturbance provides: Point Impact Discrimination Sensitive to a localized fence disturbance caused by a cut or climb. Insensitive to distributed fence noise due to wind, rain and nearby vehicles. Sensitivity Leveling Calibration automatically compensates for fence variations. Each meter of perimeter fence is equally sensitive to intrusions. Free Format Zoning Zones are set from the keyboard, independent of processor location and may be changed at will. Built-in microprocessor and PC software provide: Windows based installation program Installation and service is completed with easy to use graphic tools. Graphic annunciator map User drawn site map is converted into a basic graphic annunciator map. No other multiplexer or map display system is needed. Remote diagnostics Modem interface reports site conditions and alarm information over ordinary telephone lines. This feature allows for remote trouble shooting. Typical System Configuration Signal Control Unit Link Unit Microwave Auxiliary Sensors (Power and Data Provided) Signal Control Unit Link Unit MICRONET Graphic Display DC Power Link Unit Signal Control Unit

MICRONET s major components are the Signal Control Unit, MicroPoint cable and Windows software. The Signal Control Unit provides the system intelligence to perform powerful signal processing, DC power distribution and data communications networking. The MicroPoint cable permits the easy connection of the perimeter system providing: DC power, data communication for alarms and control, as well as an intrusion detection sensor. The MICRONET Perimeter Manager software included provides; site design, step by step installation, and graphic map display. Principle of Operation The signal control unit sends a pulse down the MicroPoint cable. The pulse is reflected back by a disturbance providing location of the intrusion along the length of cable. The received signal is sampled to create a signature which describes the reflected pulse. Digital Signal Processing (DSP) allows MicroPoint sensor to measure the location and shape of the reflected pulse. The microprocessor recognizes the shape of the response from a point target (cutting or climbing) and distinguishes it from responses caused by distributed signals such as rain, wind and vehicle traffic. The installer uses any PC to calibrate the MicroPoint cable sensor and assign zones. During calibration, the sensitivity Perimeter Monitor (Operator Graphic Display) of each (3 ft.) of cable is set to provide uniform sensitivity along the entire length of MicroPoint cable. In fence installations, Sensitivity Leveling accommodates variations in the type of fence fabric and in the fabric tension. Zones are user defined from the keyboard. Free Format Zoning allows the number and location of zones to be easily altered to meet changing site conditions. Windows based installation software provides installation guidance and records as installed details for later maintenance and diagnostic purposes. MicroPoint Sensor - Detection Concept A B MicroPoint Cables TX PULSE LOGIC RX ADC l Intrusion Pulse Response MICROPROCESSOR MicroPoint Sensor Range Cells Digitized Response Filtered Response Intrusion Location

OTHER SENSORS MicroPoint Detection and Assessment Sensitivity Leveling Free Format Zoning Point Impact Discrimination YES Locates alarms within 10 feet NO Only detects presence Intruder stands out from wind/rain NO Intruder buried in wind/rain Digital processing increases Pd $$$ External processors required Focused CCTV assessment $$$ Many more processors needed YES Calibrated every 3 feet NO One threshold for entire zone Compensates for fence variations $$$ Often requires fence work Calibration optimizes Pd vs FAR NO Pd vs FAR compromised Easy to locate problems $$$ Difficult to locate problems YES Software Controlled Zones NO Hardware defined zones Multiple zones per cable NO Only 1 zone per cable Easy to add zones $$$ Requires more processors Easy to change zone boundaries $$$ Requires reinstallation YES Recognizes local disturbances NO Responds equally to all disturbances Ignores noise from wind, rain NO Sensitivity to wind, rain, vehicles MicroPoint cable with Integrated Power and Data MICRONET Communications Computer Aided Installation YES Power & Data Superimposed NO Separate power & data wires on Transducer Cable One cable carries all $$$ Additional material & labor Secured by the sensor $$$ Requires conduit to secure Supports auxiliary sensors $$$ Separate power and data required YES Built-in FSK network NO Separate wiring required Peer to peer network $$$ Separate wiring from each sensor YES Windows based Installation and NO User Manual is rarely read, often lost Service Tools Install it right the first time $$$ Costly repairs Well documented sites NO Documentation is lost or never read Telephone maintenance & diagnostics $$$ Many unnecessary trips to site remote upload/download capability The Next Generation Perimeter Security System. * MICRONET technology is patented by Southwest Microwave, Inc. (US #5446446) MICRONET and MicroPoint are trademarks of Southwest Microwave, Inc. and Windows is a registered trademark of Microsoft Corporation. Specifications subject to change without notice. Southwest Microwave, Inc. www.southwestmicrowave.com 9055 South McKemy Street - Tempe, Arizona 85284-2946 USA Telephone 480-783-0201 FAX 480-783-0401 European Offices: Southwest Microwave Ltd. Suite 1, Deer Park Business Centre Woollas Hill, Eckington, Pershore, Worcestershire WR10 3DN, UK TEL: +44 (0) 1386 75 15 11 FAX: +44 (0) 1386 75 07 05 7/06

TM Perimeter Security Systems System Specifications System Components MicroPoint Detection locates intrusions to within 3 meters (10 feet). Point Impact Discrimination recognizes and suppresses distributed disturbances due to wind, rain and vibrations. Sensitivity Leveling automatically compensates for fence variations to equalize entire perimeter. Free Format Zoning allows the zones to be set in software independent of cable length or equipment location. MicroPoint cable provides detection, power distribution and data communications for the entire system. Windows based MICRONET Perimeter Manager with Drawing Tool and Installation and Service Tool included. MICRONET Map software with precise intrusion location displayed in color graphics. Auxiliary sensors and devices are powered and controlled by the system. Each Signal Control Unit protects up to 1310 Feet (1/4 mile), (400 meters) of perimeter. Multiple Signal Control Units can be connected together for larger lengths of perimeter. Operating voltage range (10.5-60 VDC) Temperature range -40 o C to 70 o C (-40 o F to 159 o F). Signal Control Unit Each module processes data from two lengths of Micro- Point cable (A and B). Each length of transducer cable can be up to 200 meters (650 ft) long. Both A and B lengths of transducer cable are terminated in either Link Units or Termination Units. 35.5 L x 30.5 W x 15.3H cm (14 x 12 x 6 in) Weight: 7 kg (15.5 lb) Power: 10.5 to 60 VDC at 3.5 watts (without auxiliary sensors) 12 VDC at 580 ma, 24 VDC at 260 ma and 48 VDC at 160 ma Inputs: 2 MicroPoint cables (A and B) 6 Dry contacts inputs 3 Analog inputs (0-5 V) 4 Alarms and 2 Tampers from the Link Units over the MicroPoint cable Outputs: 3 Alarm relays SPDT (Form C) - 2 amp @ 28 VDC +12 VDC at 150 ma for auxiliary sensors. Communications port for computer or relay models. (with optional 232 or 422A Adapter) MicroPoint Cable MC-115 The MicroPoint cable is used for detection, power distribution and data communications. MC-115 Type 4.902 mm (0.193 in) diameter Jacket: High density polyethylene, UV resistant, black. Minimum Bend Radius: 10 cm (4 in) Packaged: Roll Size 100m (328 ft) 200m (656 ft) Weight 4kg (9 lbs) 8kg (18 lbs)

Link Unit Link Units terminate the detection process and provide a means of interconnecting multiple Signal Control Units. They are used at the ends of the A and B MicroPoint cables. They also provide terminals to interface to auxiliary sensors. 35.5L x 30.5W x 15.3H cm (14 x 12 x 6 in) Relay Module Relay Modules communicate via RS485 to the Signal Control Unit with a Network Interface Module. It provides both NO and NC relay contacts and analog channels for external alarm panels, auxiliary controls or remote devices. Multiple Relay Modules can be connected (up to 10) to the RS 485 line. Weight: 7kg (15.5 lbs) 33.7 x 12.7 x 13.9H cm (13.25 x 5 x 5.5 in) Inputs: 2 MicroPoint cables 4 Isolated contacts Outputs: +12 VDC at 150 ma for auxiliary sensors and devices (optional with Power Converter Card) Optional Isolated Link Unit: Used on larger systems (please consult factory) Termination Unit The Termination Unit is used at the end-of-line in an open loop configuration to terminate detection process. 7.6L x 6.4W x 13.3H cm (3.0 x 2.5 x 5.25 in) Weight: 0.45 kg (1 lb) Inputs: 1 MicroPoint Cable Network Interface Module The Network Interface Module provides interface points for external connections to data and graphic displays. This module provides RS232 and RS422/RS485 data ports for external communications and real time clock. This module plugs into any Signal Control Units. Outputs: RS485 to Relay Module RS232 or RS422 to PC/modem Real time clock RS422 to Converter Weight: 1.36 kg (3 lbs) Power: 10.5 to 13 VDC at 2.0 watts (110 ma) Inputs: 6 Dry contact inputs 4 Analog Inputs (0-5 VDC) RS485 from Network Interface Module Outputs: 6 Alarm Relays SPDT (Form C) - 2 Amp @ 28 VDC Accessories: Options: 12 VDC at 150 ma for Auxiliary Sensors and devices (optional with Power Converter Card) Heavy Duty DC Power Supplies MicroPoint Cable Splice Kit 232A or 422A Adapter for Communication Connection Power Converter Card Multiple Map Graphic Display & Control Software Armored MicroPoint cables available. MICRONET and MicroPoint Cable are trademarks of Southwest Microwave, Inc. and Windows is a registered trademark of Microsoft Corporation. Specifications subject to change without notice. Southwest Microwave, Inc. www.southwestmicrowave.com 9055 South McKemy Street - Tempe, Arizona 85284-2946 USA Telephone 480-783-0201 FAX 480-783-0401 European Offices: Southwest Microwave Ltd. Suite 1, Deer Park Business Centre Woollas Hill, Eckington, Pershore, Worcestershire WR10 3DN, UK TEL: +44 (0) 1386 75 15 11 FAX: +44 (0) 1386 75 07 05 7/06