Engineering and service software For KNX and LPB plants



Similar documents
Operating Software Service Tool

COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Hotel room management software

F453. TiF453. User guide 10/11-01 PC

OZW V2.0. Web server. Synco TM, Synco TM living

DMS-10101, Computer Equipment

OZW672...V5.2. Web-Server. For LPB/BSB plants

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

TEMP MONITOR_S2 Software operation instructions

Synco, Synco living Web server OZW V5.2 Commissioning instructions

DOC PharmSpec 3. Software Manual. 10/2013, Edition 3

Network & Internet Installation & Information Guide Fall 2004 Edition. Campus Ethernet For PCs using Windows 2000 & XP

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

3D MultiVision SOFTWARE OPERATING INSTRUCTIONS

Figure 1: RotemNet Main Screen

File Management Utility. T u t o r i a l

OZW V4.0. Web server. For Synco TM, Synco TM living

1 HARDWARE AND SOFTWARE REQUIREMENTS FOR HAL E-BANK SYSTEM

System Integration Software

Web-Server OZW V5.2

Rapattoni Magic 9 Hardware and Software Guidelines

User s Manual. Management Software for Inverter

USB PC Adapter V4 Configuration

for Windows Media Center User's Guide

Item Minimum Required Recommended Notes

Synco Central Communication Unit OZW771 Basic Documentation

Sage Grant Management System Requirements

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

CMS Central Monitoring System

OZS Web server. For LPB/BSB plants

Instruction manual. testo easyheat Configuration and Analysis software

3M Occupational Health and Environmental Safety 3M E-A-Rfit Validation System. Version 4.2 Software Installation Guide (Upgrade) 1 P age

s y s t e m r e q u i r e m e n t s

Cisco IP Communicator (Softphone) Compatibility

OSM 2007 MONITORING SOFTWARE

Software Operations Manual

LOREX CLIENT Remote Software 4.0

Installing the Gerber P2C Plotter USB Driver

OPENweb. Efficient controlling at the highest level.

DCS Data and communication server

Device configurator DRC200

User Manual WatchPower

v1 System Requirements 7/11/07

User s Guide for version 5 Page

N600 WiFi USB Adapter

3M Stats and Status Software for 3M Detection System Model 8900/9900. Administrator s Guide

OZW30. Central Unit SYNERGYR

Proficy * Change Management for Proficy * Machine Edition

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

Guide to Installing BBL Crystal MIND on Windows 7

TRBOnet Enterprise 3.0

Rapattoni Magic 10 Version Date: May 1, Hardware and Software Guidelines for Customer Hosted Systems

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

for Windows 7 Laplink Software, Inc. Quick Start Guide h t t p : / / w w w. l a p l i n k. c o m / h e l p MN-LLG-EN-15 (REV.

MN POS TM. Hardware & Peripherals. All required hardware may be purchased from Home Office.

04 / Panel Design Configurator The modular planning software for low voltage distribution systems

DIGICLIENT 8.0 Remote Agent Software

VisiCount Installation. Revised: 8/28/2012

RS232 Programming and Troubleshooting Guide for Turbo Controls

GE Healthcare Life Sciences UNICORN Administration and Technical Manual

V2.8.x Installation on a Database Server Note: This document is to be used on a new database server installation.

Symantec Backup Exec 12.5 for Windows Servers. Quick Installation Guide

RDS LDS LDS USB PlantVisor 2.00

CENTAUR. Access Control Software Version 4.2 REFERENCE MANUAL

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

IXP120 Alarm Monitor Utility

PNOZmulti Configurator V8.1.1

Upgrading to Windows 8.1 A Guide for Windows 7 Users Version 1.2

Operating Instructions

Wireless LAN g USB Adapter

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Local PlantVisor. PlantWatch. Remote PlantVisor

Major upgrade versions. To see which features each version of Windows 7 has, go to Microsoft's Compare Windows page.

DATA PROCESSING SOFTWARE

StruxureWare Power Monitoring 7.0.1

Artikel-Detailinformationen

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

Operating Instructions Software (Fax Driver)

Substation Monitoring System SMS 510. Product Guide

CDR500 Spy Recovery Pro

Software installation and configuration IEC-line series

Inventory Tracking Software Operations Manual

RRV934. Multi-controller. Synco living

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

User Guide Win7Zilla

V2.7.x Installation on a Database Server Note: This document is to be used on a new database server installation.

How do I Check if My Computer is Compatible with Windows 7

Metasys Software Installation and Platform Requirements

Setting up for Adobe Connect meetings

VisionView Maintenance Utility Release Notes

TrueAlarm Fire Alarm Systems

Read Me UNISTREAM AUTOMATION IDE

Table Of Contents. System Monitoring System Monitoring Display...14 Monitoring Zones...15 About Areas (partitions)...15 Area Status Display...

Documentation. M-Bus 130-mbx

Managing Relion IEDs Protection and control IED manager PCM600

Document Capture and Distribution

SOFTWARE INSTALLATION INSTRUCTIONS

A+ Guide to Software: Managing, Maintaining, and Troubleshooting, 5e. Chapter 3 Installing Windows

Transcription:

5 649 Engineering and service software For KNX and LPB plants As of V9.00 ACS790 The engineering and service software ACS790 is for KNX and LPB plants equipped with the appropriate bus devices. The software is installed on a PC or laptop and consists of the following programs: ACS Tool ACS Alarm to engineer, commission, and operate plants to receive, list, and report faults Use Technical applications of ACS790 include: Engineering and commissioning KNX and LPB plants (see also OCI700.1 service tool). Plant operation and monitoring of Synco plants with KNX bus devices (primary controllers, individual room controllers, room units, central apartment units). Plant operation and monitoring of heating plants with LPB bus devices (controllers, pulse adapters, temperature sensors/adapters, digital input modules, relay modules). Alarming (optical, acoustic) plant and device faults. CE1N5649en 2013-11-04 Building Technologies

Overview ACS Tool The program "ACS Tool" is designed to engineer, commission and operate KNX and LPB plants with the appropriate bus devices. Plant engineering Topology Engineering Commissioning Commissioning Trend Online trend Offline trend File transfer Transfer Plant operation Popcard Plant diagram Plant topologies can be created offline with the aid of device libraries for KNX and LPB plants. Parameterize device configurations and setting values. Create the device list Write parameter file of the plant Do the Wiring test Start the plant Read plant configuration and setting values (backup and commissioning report) Record and display of the dynamic curve for selected data points. Connection between plant and ACS is required while trending. Record and display the dynamic curve of selected data points. No connection required between plant and ACS while trending data. The data is read from the central communication unit for display in ACS. File transfers from a central communication unit to ACS (and vice-versa). Plant and device operation via popcard pages Plant and device operation via plant diagrams Plant view Bus topology Site topology User view Operation Maintenance Administration Plant navigation using topology tree (structured by area, line, and device addresses). Freely definable tree structures allow for site-specific views. Only the application "Plant operation" is enabled. The data points relevant to operating the plant are displayed in ACS. The applications "Plant operation", "Online trend", "Offline trend" and "File transfer" are enabled. All applications and data points relevant to plant operation and servicing are displayed. All applications and data points are available. This view is used for plant engineering and commissioning. 2/10

ACS Alarm The program "ACS Alarm" allows for receiving, listing and alarming of plant and device faults. Alarm Plant and device faults Plant and device faults are received and saved by "ACS Alarm", and displayed as alarm messages as well as forwarded to a printer. System report Information on the system System information, i.e. on the plant, central communication unit and devices, is received by "ACS Alarm" and saved and displayed as a system report. Reports can be printed periodically. Central communication units and service interface Executable applications depend on the central units connected or the service interface (SI). ACS application WEB server, central comm. unit SI OZW775 OZW772 6) OZW771 OZW672 OCI600 OCI611 OCI700 Plant operation Topology (offline) Engineering (offline) Commissioning Online trend Offline trend File transfer Alarm System report Direct connection 2) 3) 1) 3) 1) 1) 2) Dial-up connection IP connection 5) 1) Using standard zero-modem cable 2) Using standard USB cable (plug type A to type B) 3) Using standard USB cable (plug tape A to type Mini-B) 5) OZW775 as of version V2.0 6) OZW772 as of version V2.0 3/10

Documentation Device type Synco web server OZW775 Synco web server OZW772 Synco communication unit OZW771 LPB web server OZW672 LPB communication unit OCI600 LPB communication unit OCI611 Data sheet number N5663 N5701 N3117 N5712 N2529 N2533 Service tool with interface OCI700 N5655 Ordering and delivery Ordering Please provide the type reference when ordering the software. Designation Type reference Article number Engineering und Service software ACS790 S55800-Y100 Delivery Software is delivered as a CD box which contains 2 CD-ROM with different program versions for different Microsoft Windows operating systems: Software CD 1 V8.25 CD 2 V9.00 ACS Tool ACS Alarm USB driver (RNDIS driver for web server) Windows XP Windows Vista Windows 7 Windows 7 Windows 8 4/10

Program descriptions ACS Tool Applications User view The "ACS Tool" application program includes the applications: Topology Plant engineering Plant commissioning Online trend Offline trend File transfer Plant operation The applications can be operated in parallel. Available user views include: Operation Maintenance Administration Available applications and data points are dependent on the user view An individual password can be defined for each user view. Plant view Bus topology view The plants can be displayed using user-defined tree structures in the site topology or in the bus topology The devices are displayed sorted by bus address. Example: In KNX plants, the devices are displayed structured by area, line, and device addresses. 5/10

Site topology view Freely definable tree structures allow for displaying plants specific to a building. Popcard Standard popcard A standard popcard with predefined tree structure and content for the operating pages exists for each device type. Each selected operating page is updated automatically. The circle in red (not updated) changes to black (updated) to visualize the update. User-defined popcard The administrator creates a user-defined popcard. User-defined popcards can contain data points of individual or multiple devices. Structure and content of the freely definable popcards can be customized. Standard and customized popcard can serve as the basis for creating new popcards. 6/10

Plant diagram A plant diagram corresponds to the graphical display, e.g. of a ventilation plant and may include a device or device groups. The plant can be operated and monitored with the help of data points depicted on plant diagrams. Standard diagram The software includes a library with standard diagrams (standard plant diagrams). The ACS displays the appropriate standard diagram based on device configuration (plant type). User-defined plant diagram A user-designed plant diagram can be created in the "Administration" user view: Standard and customized plant diagrams can serve as the basis for creating new plant diagrams. Data points, texts, and links can be added, deleted and edited in edit mode. An external graphics software is required for graphical displays. ACS is compatible with the following formats: BMP, GIF, TIF, JPG or PNG. Plant engineering Topology Corresponding plant topologies can be created offline with the help of device libraries for KNX and LPB plants. Engineering Engineering plant topologies created online and offline. Define parameter and settings for device configuration Communication settings (cross-device settings) Assignment of devices for monitoring Commissioning Plant commissioning Online device scan and (if available) synchronization with device list created offline Write plant file Run wiring test Start the plant and optimize settings Create a backup and the commissioning report (protocol as handover document) 7/10

Commissioning report Export as xls file Trend Online trend Offline trend Trend display The applications "Online trend" and "Offline trend" records the value curve of data points and displays them graphically. The desired data points for a plant are entered in the trend definition and the sample interval is set. Plant and ACS must be connected. Trend data is automatically started after the trend definition and the recorded data is saved in ACS. The graphical display of the trend data is online. No connection between plant and ACS. The trend data is saved on the central communication unit. Start and end of trend can be defined. They are read from the central communication unit to graphically display the trend data in ACS. "Offline trend" is only available on some dedicated central communication units, please refer to page 3. The data point values are displayed per the sampling rate in trend (for example, a sampling rate of one minute). 8/10

Export as xls file Trend data can be printed, saved as pdf or rtf and exported as xls file. File transfer ACS Alarm Applications The application "File transfer" exchanges files between a central communication unit and ACS. Transfer functions include: Files copied from the central communication units or their storage cards in ACS (or vice-versa as well, depending on central communication unit type). Format storage cards for central communication units. File transfers are only available for specified central communication unit types, see table on page 3. The "ACS Alarm" application program includes applications to receive and process alarms as well as reporting plant state. Alarm Alarms, based on plant and device faults, are entered on the ACS alarm list upon receipt. Configurable alarm functions also include: Trigger optical/acoustic signal Open popup window Print alarm message Any combination of the three System report A system report provides a general overview on the plant operating state and included the following information: Plant name Plant state Transmission time, date Plant phone number Central communications type Even more information, e.g. operating hours or meter values, may be include in the system report depending on the central communication unit type. 9/10

Engineering notes Limitations ACS Tool Online, offline trend Limitation No continuous operation Number of devices in popcard and plant diagram Online trend Trend file (plx) max. 100 MB Offline trend ACS project file max. 100 MB Description ACS Tool is not suited for 24-hour operation. We recommend closing and restarting the "ACS Tool" program at least once a day. Updating data point values takes longer if a lot of data points are on the same popcard or plant diagram. Please note that the ACS project file may not exceed 100 MB. Longer periods of trending result in very large ACS project files. This is prevented by restarting the program every 24 hours. We recommend exporting trend data daily and then deleting. The project must be closed after deletion to compress the file. Please note that the ACS project file may not exceed 100 MB. The trend data must be exported to Excel as needed and then deleted in the ACS project (see Online trend) Technical data Compatibility Plant files from ACS700 to ASC785 are compatible with ACS790 as of V5.0. Number of devices per plant The number of devices per plant depends on the central communication unit used, but the central communication units can only monitor a limited number of devices, please refer to the corresponding datasheets. Modem driver The modem driver (TAPI) available on the PC/Laptop operating system is compatible with ACS. PC/Laptop requirements with ACS Processor RAM Hard disk Screen Interfaces Minimum requirements 1 GHz 1 GB 2.0 GB of available storage for installation Additional storage space required for plant data SVGA standard driver 1024 768, 256 Colors USB 1.1 and higher Serial COM up to 19,200 baud Network card (Ethernet) Operating system Microsoft Windows 7 as of Service Pack 1, 32- und 64- bit versions Microsoft Windows 8, 32- und 64-bit versions Microsoft DotNet Framework 4.0 (included on the CD). Drive CD-ROM or DVD 2011-2013 Siemens Switzerland Ltd Subject to change 10/10