CHROMOCTANE O N LINE ANALYZER



Similar documents
23 The Thermal Conductivity Detector

Process Instrumentation

AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance

Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

On-line Dissolved Gas Analysis

Agilent 7697A Headspace Sampler Data Sheet

The Use of Hydrogen Carrier Gas for GC/MS

BTU ANALYSIS USING A GAS CHROMATOGRAPH

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

C184-E014D GC Shimadzu Gas Chromatograph System

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Addressing the World Helium Shortage For Gas Chromatography

Clarus 580 Gas Chromatograph

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Get the Right GC for Your Industry

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Natural Gas Processing Solutions Using the 700XA Gas Chromatograph

Online Infrared Flue Gas Analyzer Gasboard 3000

Micro GC Fusion Pre-Installation Checklist

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Capillary and Packed Gas Chromatograph

Transformer Oil Gas Analysis

API Marine. BMS Presentation. Ballast Measurement Systems

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Analytical Service Certification Program

Appendix 5 Overview of requirements in English

Designed for multi-injector endurance testing, the

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Overview. Inficon s Product

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

COMBIMASS. Technical Data COMBIMASS eco-bio +

RGC-IR Remote Gas Calibrator for IR400

FACE GASOLINES AND BLENDS WITH ETHANOL: DETAILED CHARACTERIZATION OF PHYSICAL AND CHEMICAL PROPERTIES

Rosemount Analytical 1500XA Process Gas Chromatograph

AC SIMDIS Solutions. True Boiling Point Distribution up to C120. Compliance with Global Standard Test Methods

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Hydrogen as an alternative to Helium for gas chromatography.

Thermal Conductivity Detector

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Chromatograph Maintenance and Troubleshooting Class # 5050

Process Gas Chromatograph

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

SYNSPEC GC s ALPHA 115 and ALPHA 116

Thermo Scientific ConFlo IV Universal Interface

Samples RMN Analytical Report ( ) GC/FID Analysis (RM01) Nicotine Purity

Agilent Veriflow 500 Electronic Flowmeter. Flow Range: sccm. Operation Guide. Agilent Technologies

OEM-EP Pressure Controllers

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Rackmount Intelligent Pressure Scanners

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 17: Evaluation of crude

TRL-onlineTOC Monitor is designed for monitoring carbon content in

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

REGTRONIC OPERATING INSTRUCTIONS

Fundamentals of Mass Flow Control

SULFUR COMPOUNDS IN PETROLEUM HYDROCARBON STREAMS

Gas Chromatography Liner Selection Guide

RECOMMENDED SPECIFICATION. Cogent Environmental OVA-5000 Heavy Metal Analyzer. to Monitor Total Dissolved Arsenic. for

MB3600-HP12 / Measurement & Analytics. Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

GC-2010 Gas Chromatograph INSTRUCTION MANUAL

Series 2. Air Server. Options for UNITY 2. A robust, cryogen-free solution for round-the-clock on-line air monitoring

Danalyzer Model 700 Gas Chromatograph

AMD Analysis & Technology AG

Gas Detection for Refining. HA University

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

S300 Series Dust Monitors

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

EnAlgae SOP: Biogas analysis

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Calculating Volatile Organic Compounds (VOC) Flash Emissions from Crude Oil and Condensate Tanks at Oil and Gas Production Sites

Micro Cryo-Trap Model 971

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

SMM. Installation Operation Maintenance

K-Type Thermocouple Sensor User s Guide

Gas Custody Transfer Calibration

The Electron Capture Detector (ECD)

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

Power consumption (kw)

The Relation Between Gasoline Quality, Octane Number and the Environment

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Precision Mass Flow Metering For CVD Applications.

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

Dynamic Models Towards Operator and Engineer Training: Virtual Environment

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Transcription:

GECIL Process GT instruments CHROMOCTANE O N LINE ANALYZER ASTM D6733 DHA and RON and MON on line GC for Reformer unit Automatic Chromatographic system for analysis of naphta feeds and reforming gasolines in accordance wuth ASTM DHA method D6733. In addition to simulated distillation data and chemical individual and group hydrocarbon characterization, various physical properties are generated such as RON, MON, RVP, SG Etc. Based on the embedded GC HP5890 Plus at the introduction of Chromoctane, it now includes last generation HP6890 GC and software Chemstation Technical Hardware specifications of CHROMOCTANE HP 6890N GC with FID EPC detector, Split injector with EPC, automatic liquid injection valve, automatic gas injection valve, pre-vaporization chamber for liquid samples and auxiliary valves for selection of sample lines. PC Chemstation Workstation with CARBURANE automatic labelling software and databases The above can be install in existing Explosion proof shelter or in an Ex HPGC6890 Cabinet Date: 01/2003

Page 2 Main Functions Software Specifications The analytical system is based on the combination of gas chromatographic analysis and original software and databases developed by IFP. Only a very small sample is required and testing time does not exceed 90 minutes. The method is very stable and efficient to give excellent accuracy of the results. Typically calibration is done every 12 months in spite of feedstock variation specifications. Typical applications in Reforming operations are for example : Reformer Feed ( Naphta Feedstock ) Reformer inter reactor effluents Reformate after stabilization The software package provides several features for operating staff : Selection of Feeds and effluents Calibration, Identification and Quantification of chromatograms Determination of physical properties The final report automatically generated by Chromoctane can include all of the following data on the sample analysis : DHA report Detailed Hydrocarbons Analysis Hydrocarbon group report Carbon number group report Carbon and Hydrogen content Simulated distillation report Physical properties such as specific gravity, molecular weight, RON, MON, Etc... Example of installation on semi-regenerative reforming Chromoctane on line analyzer is using state of the art GC integration and control software Chemstation along with the well known Carburane DHA software from IFP. All above are compatible with the latest version of Windows such as 2000 Pro, NT, or XP Pro. The supervisor software allows the operator to perform the following : Select the sample line(s) Assign a GC Method for Each line Define the sequence of operation ( with a purge period) for effluent injection at preset times and by priority Access in real time to the chromatographic data during an analysis Automatically link the integration software to Carburane to generate direct final report. The Carburane identification software allows to : Carry out automatically the identification of all components in the sample and labeling each of them. Control automatically the calibration of the GC and adjust the experimenting times to properly identify the components. If out of range the system will send a warning Introduce new calibration data To process report in post run mode or automatically. To modify databases by advance analytical specialist

GECIL Process GT instruments Page 3 GC Hardware detail specifications Inlet Auto injector Split capillary inlet installed with EPC Electronic pressure/flow control, 400 C maximum operating temperature, Pressure setting range: 0-100 psi (0-150 psi optional). Total flow setting range: 0 to 1,000 ml/min He Detector include electronic pneumatics control and electronic on/off for all detector gases. One detector installed with EPC : Flame ionization detector (FID) Electronic pressure/flow control optimized for capillary Columns 450 C maximum operating temperature, Flame-out detection, MDL: <5 pg carbon/sec as propane using N2 carrier and 0.29-mm id jet, Linear dynamic range: <±10%, 107 with N2 carrier and 0.29-mm id jet, Data rate: up to 200 Hz Electronic Pneumatics Control (EPC) Channels for inlets, detectors, or auxiliary gases Pressure adjustable by increments of 0.01 psi Atmospheric pressure sensor to compensate for altitude and ambient temperature variation Flow or pressure setpoints on each inlet or detector parameter screen EPC settings included in Agilent 6890 and Carburane Workstation Data Communications : LAN, RS-232- C (57,600 baud maximumis settable from keyboard), Two analog output channels (1-mV, 1-V, and 10-V output available) as standard, Remote start/stop Other Specifications Clock time programming- Run deviation log (notes any changes to setpoints or expected values during a run, saved with run file ) - Control of eight external events (valves, on/off, or low-level contact) - Four internal 24-volt connections(up to 150 ma) - Two external 24-volt connections (up to 75 ma) - Two on/off contact closures (48 V, 250 ma max) - Storage of nine methods- Storage of five sequences- Binary-coded decimal input for a stream selection valve- Context-sensitive online help. Analytical Data Naphta Feed Analysis up to about 220 peaks separated and identified The optimized method gives a minimum number of coeluted compounds, achieves separation of major compounds which are not easily separated, especially naphtenes and alkanes. Quantification in weight % of each component with response factor, by carbon number, by hydrocarbon group PNA analysis Quantification in weight % of carbon and hydrogen content, of alkane, naphthene and aromatic carbon content. Simulated distillation report in two formats in %W or %V or % mole with value every 5% or every 1% Reformate Analysis About 200 peaks separated and identified up to C10 for saturates and up to C16 for aromatics Quantification in weight % of each component with response factor, by carbon number, by hydrocarbon group PIONA analysis Simulated distillation report in two formats in %W or %V or % mole with value every 5% or every 1% Physical properties determination : - Specific gravity and molecular weight - Octane numbers calculated from linear correlation with blending number of each peak obtained from more than 200 samples reforming gasoline - Octane number range of these samples RON from 85 to 105 MON from 76 to 85 - Accuracy obtained with Carburane Bias better than 0.7 Standard deviation RON = 0.30 MON = 0.34 Repeatability 0.1 Inter Reactor Analysis Sample specifications : gaseous at 500 C with pressure 5 to 10 bar and average composition 80% hydrogen, 20% C1-C11 hydrocarbons. Sampling of after depressurization to 1 bar with a temperature sampling line at 160 C Simulation of stabilized effluent with the software by removing C1-C2-C3 and part of C4 Analysis report same as Reformate

UTILITIES Gases for analyzer - Helium ( for Carrier gas ) Purity : 99.995% Consumption 250L / day - Hydrogen ( for FID) Purity : 99.995% Consumption 50L /day - Air ( for FID) Purity 99.995% Consumption 500L /day Additional gases for EX cabinet - Instrument air pressure 5 to 10 bars Electrical power - for the analyzer 220V 50/60Hz +/- 10% 3KVA - For the EX cabinet 220V 50/60Hz +/-10% 30 Amps Dimensions Ex cabinet - 122 cm overall W x 107 cm D x 214 cm H - Weight approx. 450 Kgs with GC and sampling system GECIL Process GT instruments 14 Route de Saint Romain 2911 South Shore Blvd. 69450 Saint Cyr au mont d or Suite 110 FRANCE League City, TX 77573 USA Phone : (33) 4 72 53 23 93 Phone: 1 281-334-5015 Fax : (33) 4 78 47 28 03 Fax: 1 281-538-3622 Email: info@gecil.com Email:info@gtinstruments.com