1 Pore size and BET surface area analysis at your fingertips. SA 3100 Gas Adsorption Analyzer
2 The History of Beckman Coulter Particle Characterization Introducing The SA 3100 Surface Area and Pore Size Analyzer A complete solution for characterizing the surface of solid materials. The SA 3100 utilizes the well-established gas adsorption technique to measure the surface area and porosity of solids. Everything you need is incorporated into one powerful and easy-to-use package. With an internal PC and flexible software, the SA 3100 gives you the information you need: BET and Langmuir surface area, BJH Adsorption and Desorption, Pore Size Distribution, t-plot, total pore volume and more. Data is displayed in real-time on the easy-to-read touch screen. Plus, the SA-View Windows viewing software allows you to view, print and archive your data. Whether you are in a quality control or R&D environment, the SA 3100 is the most versatile and easy-to-use gas adsorption analyzer available today. For over 40 years the Particle Characterization Group (PCG) of Beckman Coulter has provided answers and solutions to those involved in the testing and measurement of the physical properties of particles. Offering a complete family of instruments, including: History of Innovation Coulter Counters 1954 Pore Characterization Analyzers 1975 Photon Correlation Spectroscopy Analyzers 1983 Zeta Potential Analyzers 1988 Laser Diffraction Analyzers 1989 Surface Area/BET Analyzers 1993 Digital Pulse Processing 1999 Image Analyzers 2000 We are in a unique position to offer solutions for most particle analysis needs. World-class support, including being listed as an ASTM certified laboratory and with service only a company such as Beckman Coulter can provide. Purchasing an instrument from us will deliver performance, versatility and peace of mind. The Beckman Coulter Technology Center
3 Designed with The Technology the user in mind. The gas adsorption technique is performed Taking ease-of-use to a new level. by the addition of a known volume of gas (adsorbate), typically nitrogen, to a solid material in a sample vessel at cryogenic temperatures. At cryogenic temperatures, weak molecular An innovative touch screen allows easy control of all instrument functions without the use of an external computer. A completely integrated, fully automated system allows for true walk-away analysis. Intuitive software prompts the user each step of the way. Using the latest technology to achieve maximum speed of analysis. Intelligent Learn function decreases analysis time of routine samples by referencing stored sample isotherms. Novel sample tube design minimizes equilibration time. attractive forces will cause the gas molecules to adsorb onto (attach to the surface of) a solid material. An adsorbate (gas) is added to the sample in a series of controlled doses, the pressure in the sample vessel is measured after each dosing. There is a direct relationship between the pressure and the volume of gas in the sample vessel. By measuring the reduced pressure due to adsorption, the Concurrent manifold dosing during sample equilibration eliminates unnecessary delays. Combining versatility, accuracy and power for a complete solution. A Sample Port, three degassing ports, a powerful CPU, vacuum pump and automated dewar lift are all integrated into a single unit. Nitrogen, Argon or Krypton adsorbate gases can be used to meet your application needs. Exceptional Accuracy is achieved by referencing the true saturation vapor pressure for each data point. ideal gas law can then be used to determine the volume of gas adsorbed by the sample. The resulting relationship of volume of gas adsorbed vs. relative pressure at constant temperature is known as an adsorption Isotherm. From the analysis, and the cross-sectional area of the adsorbate gas molecule, the surface area and pore size distribution of the sample can be derived. The SA-Prep Surface Area Outgas Station For customers who need extra capacity Prepare up to 6 samples simultaneously Flow degassing with Nitrogen, Argon or Helium Temperature range from ambient to 400 C
4 Sample Analysis Has never been so simple. The User-defined Sample Profiles make using the SA 3100 incredibly simple. Choose a profile and you can produce results quickly, accurately and easily. Running samples is as easy as Load your prepared sample in the analysis position. 2 2 Select a profile. 33 View your results in minutes. The SA 3100 utilizes a totally self-contained vacuum system. Easy to read screen complete with simple touch pad operation. Sample pre-treatment or outgassing is completely internal. No additional outgassing apparatus is required. Sample outgassing is done concurrently with sample analysis. Automated Dewar Lift for walk-away operation.
5 Software The SA-View data archiving and viewing software gives you the flexibility you need. Drop-down menus and toolbars let you view all aspects of your data, the way you want to see it, quickly and easily. Is reproducibility important to you? The overlay function lets you compare data from run to run, instrument to instrument, or last year and today. Print reports directly from the SA 3100 or from the SA-View software. The choice is yours. View isotherms, data tables, BET plots and more, from one or several samples, at a glance. Applications Adhesives Alloys Abrasives Carbonates Carbons Catalysts Cements Ceramics Clays Cosmetics Detergents Explosives and Ordnance Fibers Films Fertilizers Filters Glass Food Additives Graphite Metal Powders Minerals Paper Pharmaceuticals Pigments Polishing Compounds Polymers Resins Soils and Sediments
6 WORLDCLASS GLOBAL SUPPORT AUSTRALIA (61) GERMANY (49) MEXICO (52) SWEDEN (46) CANADA (1) HONG KONG (852) NETHERLANDS (31) SWITZERLAND CHINA (86) ITALY (39) SINGAPORE (65) TAIWAN (886) EASTERN EUROPE, MIDDLE EAST AND AFRICA (41) FRANCE (33) JAPAN (81) LATIN AMERICA (1) (305) SOUTH AFRICA (27) / 5 SPAIN (34) UNITED KINGDOM (44) UNITED STATES (1) Visit our web site: TECHNICAL SPECIFICATIONS SURFACE AREA MEASUREMENT RANGE SPECIFIC SURFACE AREA RANGE: From >0.01 m 2 /g PORE SIZE RANGE MESOPORE SIZE DISTRIBUTION RANGE: 3 to 200 nm MICROPORE VOLUME AND AREA BET SURFACE AREA TYPICAL REPRODUCIBILITY: <2% CV PRESSURE MEASUREMENT OVERALL PRESSURE RANGE: Vacuum to 1000 mm Hg MINIMUM RELATIVE PRESSURE: 6 x 10-5 SAMPLE PRESSURE RESOLUTION: mm Hg TRANSDUCER LINEARITY: <0.1% BFSL TRANSDUCER REPEATABILITY: % BFSL CALIBRATED MANIFOLD TEMPERATURE AT: 45 C Stability ± 0.1 C VACUUM PUMP VOLUME RATE DISPLACEMENT: 1.5 m 3 /hr POWER CONSUMPTION: 130W ULTIMATE VACUUM: 10-3 mm Hg SAMPLE PREPARATION SYSTEM NUMBER OF OUTGAS PORTS: 3 FURNACE SPECIFICATIONS TEMPERATURE Range: 30 to 350 C Settability: 1 C Stability: 5 C Accuracy: ±5 C ENVIRONMENTAL AND POWER REQUIREMENTS UNIVERSAL ONE-DESIGN: Autoswitch power supply, Volts 50/60 Hz. 150W OPERATIONAL POWER CONSUMPTION: Nominally 500W OPERATING TEMP. RANGE: C STORAGE TEMP.: 0-50 C OPERATING ALTITUDE: up to 10,000 ft. above MSL OPERATING/STORAGE RELATIVE HUMIDITY: 10-85% RH non-condensing GAS REQUIREMENTS GAS PURITY: Helium % Absorbates 99.9% (or better) DIMENSIONS 71.1 cm (21 ) height x 50.8 cm (20 ) width x 53.3 cm (21 ) depth WEIGHT: 80 lbs. with vacuum pump COULTER, COULTER COUNTER, Beckman Coulter are registered trademarks of Beckman Coulter Inc. Copyright 2000 Beckman Coulter Inc. All rights reserved. Specifications subject to change without notice. MS Windows is a registered trademark of Microsoft Corp. P/N: RevC
FINESORB-3020. Surface Area. as or more than 0.1-2000m 2 /g. Distribution of Pore 0.35-500nm. Degas & Analysis Up to 12 Degas & 6 Analysis Station
1 FINESORB-3020 Surface Area and Porosimetry Analyzer Finesorb-3020 is Surface Area and Porosimetry Analyzer based on vacuum system from fintec instrument company.you could do the Surface Area analysis,aperture
PHYSISORPTION DETERMINATIONS
G A S S O R P T I O N A N A L Y S I S PHYSISORPTION DETERMINATIONS Most atoms that make up a solid are bound on all sides by other atoms in the bulk of the solid. The atoms on the surface of the solid,
ASAP 2460. Accelerated Surface Area and
ASAP 2460 Accelerated Surface Area and Porosimetry System Analytical Versatility with Superior Throughput ASAP 2460 Accelerated Surface Area and Porosimetry System The ASAP 2460 Surface Area and Porosimetry
TriStar II Surface Area and Porosity Analyzer
TriStar II Plus TriStar II Surface Area and Porosity Analyzer Analytical Versatility/ High Throughput/ Small Footprint Surface area and porosity are important physical properties that influence the quality
Texture characteristic of membrane materials ASAP, BET
Texture characteristic of membrane materials ASAP, BET Theory Specific surface (surface area) is used for the characterization of many materials. There are various techniques how measure the specific surface
BET Surface Area Analysis of Nanoparticles
OpenStax-CNX module: m38278 1 BET Surface Area Analysis of Nanoparticles Nina Hwang Andrew R. Barron This work is produced by OpenStax-CNX and licensed under the Creative Commons Attribution License 3.0
Analytical Services. Part number Measurement Description. Single-Point BET with Nitrogen 06000-1N. Multi-Point BET With Nitrogen 06000-3N
06000-1N 06000-3N Single-Point BET with Nitrogen Multi-Point BET With Nitrogen Single-point BET specific surface area (P/Po = 0.3) by nitrogen adsorption at 77K. Dynamic flow method unless otherwise requested.
The PMI Advanced. BET SORPTOMETER BET-201-AELC-2OS Not just products...solutions!
The PMI Advanced BET SORPTOMETER BET-201-AELC-2OS Not just products...solutions! DESCRIPTION The Fully automated equipment is intended for measurement of adsorption characteristics of various gases on
TriStar II 3020. Surface Area and Porosity System. The Science and Technology of Small Particles
TriStar II 3020 Surface Area and Porosity System The Science and Technology of Small Particles Analytical Versatility/High Throughput/Small Footprint TriStar II 3020 Surface Area and Porosity System Surface
EXPERIMENTAL METHODS IN COLLOIDS AND SURFACES
EXPERIMENTAL METHODS IN COLLOIDS AND SURFACES PARTICLE SURFACE AREA FROM GAS ADSORPTION TYPES OF ADSORPTION Physical adsorption: rapid, depends on adsorbate bulk concentration, multiple molecular layers
Standard Test Methods for Carbon Black Surface Area by Multipoint B.E.T. Nitrogen Adsorption 1
Designation: D 4820 99 Standard Test Methods for Carbon Black Surface Area by Multipoint B.E.T. Nitrogen Adsorption 1 This standard is issued under the fixed designation D 4820; the number immediately
Surface Area and Porosity
Surface Area and Porosity 1 Background Techniques Surface area Outline Total - physical adsorption External Porosity meso micro 2 Length 1 Å 1 nm 1 µm 1 1 1 1 1 mm macro meso micro metal crystallite 1-1
Adsorption. December 2014
Adsorption December 2014 1 Nanosized objects have a large surface area Dividing the size of an object by 2... doubles the accessible surface 2 Adsorption Absorption Absorption is a phenomenon that occurs
presented by Neal Leddy CMA Analytical Workshop 2012 SURFACE AREA AND POROSITY
presented by Neal Leddy CMA Analytical Workshop 2012 SURFACE AREA AND POROSITY Adsorption When a gas or vapour phase is brought into contact with a solid, part of it is taken up and remains on the outside
Physical Chemistry Practical Course, Oxford University. Determination of the Surface Area of Alumina by Nitrogen Adsorption at 77K (4 points)
Physical Chemistry Practical Course, Oxford University 1.06 Determination of the Surface Area of Alumina by Nitrogen Adsorption at 77K (4 points) What you will do In this experiment you will study the
Pharmaceutical Physical Characterization: Surface Area and Porosity
Whitepaper Authors: Dr John M. Zielinski Intertek Chemicals & Pharmaceuticals, Allentown, USA Dr Lorna Kettle Intertek Chemicals & Pharmaceuticals, Manchester, UK Date: April 2013 Pharmaceutical Physical
Keysight Technologies How to Choose your MAC Lever. Technical Overview
Keysight Technologies How to Choose your MAC Lever Technical Overview Introduction Atomic force microscopy (AFM) is a sub-nanometer scale imaging and measurement tool that can be used to determine a sample
Appendix A. Fig. 1 Nitrogen adsorption for Activated Carbon from Norit
Appendix A Summary Report Surface Area BET Surface Area: 1555.9551 m²/g Langmuir Surface Area: 1992.1415 m²/g Pore Volume Single point adsorption total pore volume of pores 0.619747 cm³/g t-plot micropore
G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method
G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality
Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data
Low cost ICP-OES analysis high quality data The NEW Thermo Scientific icap 7000 Series ICP-OES provides low cost multi-element analysis for measuring trace elements in a diverse sample range. The instrument
Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index
Toner cartridges Supplies 1 Warning: Do not touch the cartridge roller located under the cover. Cover Your printer uses four separate toner cartridges, one for each color: cyan, yellow, magenta, and black.
Motivation Physisorption Chemisorption Outlook
Surface area determination - physisorption and chemisorption Literature: Motivation Physisorption Chemisorption Outlook 1. DIN ISO 9277: BET method 2. DIN 66136: Dispersion measurement of metals 3. DIN
ADSORPTION OF N2 ON SILICA GEL
Chapter 6. Adsorption of N 2 41 6 ADSORPTION OF N2 ON SILICA GEL The purpose of this experiment is to study the adsorption of gases on solid surfaces and to introduce you to some aspects of vacuum technique
G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method
G4 ICARUS HF Simultaneous Determination of Carbon and Sulfur in Solids Innovation with Integrity Combustion Method High Performance Carbon & Sulfur Analyzer Combustion Method with High-Frequency Furnace
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
INSTALLATION AND OPERATION OF AUTOSORB-l-C-8 FOR BET SURFACE AREA MEASUREMENT OF POROUS MATERIALS
PINSTECH-221 INSTALLATION AND OPERATION OF AUTOSORB-l-C-8 FOR BET SURFACE AREA MEASUREMENT OF POROUS MATERIALS Abdul Sattar Ali Khan Chemistry Division Directorate of Science Pakistan Institute of Nuclear
Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System
Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System Carlton G. Slough TA Instruments, 109 Lukens Drive, New Castle DE 19720, USA ABSTRACT The use of
[ Care and Use Manual ]
PREP Calibration Mix DIOS Low i. Introduction Pre-packaged PREP Calibration Mixtures eliminate the need to purchase and store large quantities of the component calibration reagents, simplifying sample
This document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 18852 Third edition 2015-06-01 Rubber compounding ingredients Determination of multipoint nitrogen surface area (NSA) and statistical thickness surface area (STSA) Ingrédients
ProteinChip Energy Absorbing Molecules (EAM)
ProteinChip Energy Absorbing Molecules (EAM) Instruction Manual Catalog #C30-00001, #C30-00002, #C30-00003, #C30-00004 For technical support, call your local Bio-Rad office, or in the US, call 1-800-4BIORAD
(S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26)
Chem 367-2/ Physical Adsorption 63 PHYSICAL ADSORPTION (S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26) The sample used in this experiment needs to be conditioned for at least two hours before the experiment;
Effect of surface area, pore volume and particle size of P25 titania on the phase transformation of anatase to rutile
Indian Journal of Chemistry Vol. 48A, October 2009, pp. 1378-1382 Notes Effect of surface area, pore volume and particle size of P25 titania on the phase transformation of anatase to rutile K Joseph Antony
1.5 GHz Active Probe TAP1500 Datasheet
1.5 GHz Active Probe TAP1500 Datasheet Easy to use Connects directly to oscilloscopes with the TekVPI probe interface Provides automatic units scaling and readout on the oscilloscope display Easy access
Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID
Thermo Scientific Compound Discoverer Software A New Generation of integrated solutions for small molecule structure ID Transforming Small Molecule Research Solutions for Small Molecule Structural ID Thermo
Micromeritics BET Surface Area and Porosity Analyzer Instrument Information and Generalized Standard Operating Procedure
Micromeritics BET Surface Area and Porosity Analyzer Instrument Information and Generalized Standard Operating Procedure Micromeritics ASAP 2020 Surface Area & Porosity Analyzer Location: W108 Plant Science
Agilent Automotive Power Window Regulator Testing. Application Note
Agilent Automotive Power Window Regulator Testing Application Note Abstract Automotive power window regulator tests require the use of accurate data acquisition devices, as they cover a wide range of parameters
Low Temperature Adsorption Versus Pore Size in Activated Carbons
Low Temperature Adsorption Versus Pore Size in Activated Carbons D. Martins 1, I. Catarino 1, D. Lopes 1, I. Esteves 2, J.P. Mota 2, G. Bonfait 1 1 CEFITEC Departamento de Física, Faculdade de Ciências
Development of porous materials for hydrogen storage
Development of porous materials for hydrogen storage Shinji Oshima, Osamu Kato, Takeshi Kataoka, Yoshihiro Kobori, Michiaki Adachi Hydrogen & New Energy Research Laboratory Nippon Oil Corporation 8, Chidoricho,
Use the BET (after Brunauer, Emmett and Teller) equation is used to give specific surface area from the adsorption
Number of moles of N 2 in 0.129dm 3 = 0.129/22.4 = 5.76 X 10-3 moles of N 2 gas Module 8 : Surface Chemistry Objectives Lecture 37 : Surface Characterization Techniques After studying this lecture, you
Thermo Scientific ConFlo IV Universal Interface
m a s s s p e c t r o m e t r y Thermo Scientific ConFlo IV Universal Interface The Universal Interface Part of Thermo Fisher Scientific ConFlo IV Universal Interface The Universal Interface The development
TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System
TECHNICAL SPECIFICATION StirLIN-1 Economy Liquid Nitrogen System Reference 80 8120_01 Issue Date August 1, 2015 1. INTRODUCTION Since more than sixty years Stirling Cryogenics has designed and manufactured
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
Supporting Information
Supporting Information Copyright Wiley-VCH Verlag GmbH & Co. KGaA, 69451 Weinheim, 2013 A Study of Commercial Nanoparticulate g-al 2 O 3 Catalyst Supports Yahaya Rozita, [a] Rik Brydson,* [a] Tim P. Comyn,
Agilent Television Power Consumption Testing. Application Note
Agilent Television Power Consumption Testing Application Note Introduction Today, there are many types of televisions (TVs) on the market: the cathode ray tube (CRT) TV, liquid crystal display (LCD) TV,
Integrating CaliberRM with Software Configuration Management Tools
Integrating CaliberRM with Software Configuration Management Tools A Borland White Paper By Jenny Rogers, CaliberRM Technical Writer January 2002 Contents Introduction... 3 Enabling SCM for a Project...
Microsoft Voucher Ordering Processes
Microsoft Voucher Ordering Processes *For purposes of this document, the term Member applies to all Microsoft Members, Academic, ITA and Learning partners. Pearson VUE Voucher Store The Pearson VUE Voucher
How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens
Molecular Imager Gel Doc XR+ Installation Guide To install your Gel Doc XR+, perform these seven steps in the following order: 1. Unpack the Gel Doc XR+ system. 2. Install Image Lab software. 3. Set up
Industrial Robotics Solutions
Industrial Robotics Solutions Complete Solutions for Discovery Research Genomics Proteomics Cell Analysis Centrifugation Lab Tools Particle Characterization Bioseparation Lab Automation BR-10552A The Anatomy
Computer Specifications
Computer Specifications Specifications Imaging Systems Bulletin 6126 These tables list current specifications for Bio-Rad imaging systems. Refer to the following pages for information about each imaging
Reducing Cycle Times and Work in Process Management Costs: Aerospace and Defense Industry
Reducing Cycle Times and Work in Process Management Costs: Aerospace and Defense Industry CYCLE TIMES AND COST CHALLENGES In Aerospace and Defense environments, the longer work stays in process, the longer
10 Reasons to Choose Image-based ID Readers. White Paper
10 Reasons to Choose Image-based ID Readers White Paper 10 Reasons to Choose Image-based ID Readers INTRODUCTION Image-based ID readers stand poised to replace laser scanners in a wide range of industries
Image Lab Software for the GS-900 Densitometer
Image Lab Software for the GS-900 Densitometer Quick Start Guide Catalog # 170-9690 Bio-Rad Technical Support For help and technical advice, please contact the Bio-Rad Technical Support department. In
MILESTONE H E L P I N G C H E M I S T S
MILESTONE H E L P I N G C H E M I S T S 8 good reasons to choose the Milestone DMA-80 1. No sample preparation The DMA-80 does not require any sample preparation or other wet chemistry prior the analysis.
PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE
PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE APPLICATIONS NOTE FOR MEASUREMENTS AT THE ENTRANCE AND EXIT OF A THIRD STAGE SEPARATOR
Keeping ahead through Claisse expertise in sample preparation by fusion. Safe, simple, high performance
Keeping ahead through Claisse expertise in sample preparation by fusion Safe, simple, high performance how TO reach efficiency with Claisse Expertise? Claisse offers a global solution in sample preparation
White Paper. 10 Reasons to Choose Image-based Barcode Readers
White Paper 10 Reasons to Choose Image-based Barcode Readers Introduction Image-based barcode readers are rapidly replacing laser scanners in a wide range of industries including food, beverage, consumer
Hydrogen Adsorption on Nanoporous Biocarbon
Hydrogen Adsorption on Nanoporous Biocarbon Mikael Wood, Jacob Burress, Cintia Lapilli, Peter Pfeifer, Parag Shah, Galen Suppes University of Missouri-Columbia Phillip Parilla, Anne Dillon National Renewable
ab204067-vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use.
ab204067-vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use. Version 2 Last Updated 06 November 2015 Table of Contents INTRODUCTION 1.
Barcode Labeling in the Lab Closing the Loop of Patient Safety
Barcode Labeling in the Lab Closing the Loop of Patient Safety INTRODUCTION Detecting and preventing errors that threaten patient safety is a closed-loop process that begins at the point of care, extends
still different technique of assessment.
D E N S I T Y A N A L Y S I S Micromeritics gas pycnometers are being used worldwide to obtain material density measurements. These measurements are necessary in the manufacture of many of today s products.
ISO 12800 INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 12800 First edition 2003-12-01 Nuclear fuel technology Guide to the measurement of the specific surface area of uranium oxide powders by the BET method Technologie du combustible
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software Technical Brief Introduction The MSO70000 Series Mixed Oscilloscope, when coupled with SignalVu Spectrum
Heterogeneous Catalysis and Catalytic Processes Prof. K. K. Pant Department of Chemical Engineering Indian Institute of Technology, Delhi
Heterogeneous Catalysis and Catalytic Processes Prof. K. K. Pant Department of Chemical Engineering Indian Institute of Technology, Delhi Module - 03 Lecture 10 Good morning. In my last lecture, I was
TORKEL 820 Battery Load Unit
TORKEL 820 Lightweight Expandable system Rugged and reliable for field use Test without disconnecting the battery from the equipment it serves Description During a power outage, crucial telecommunication
INSITE. Dimension Data s monitoring offering
Dimension Data s offering What s on your mind? Is your infrastructure management strategy optimal? Are you achieving optimum ROI on your infrastructure management investment? Are you employing the latest
-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!
-86 C Freezer Accessories New Brunswick Freezer Accessories A wide selection of racks, monitoring systems and more! A Wide Range of Accessories The Perfect Complement for Your Ultra-Low Temperature Freezer
Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators
Atlas Copco On-site Industrial Gases Nitrogen & Oxygen Generators A secure supply of nitrogen and oxygen Whether your company is specialized in chemical manufacturing, electronics, laser cutting or food
DMA-1 Direct Mercury Analyzer
DMA-1 Direct Mercury Analyzer www.milestonesrl.com MILESTONE H E L P I N G C H E M I S T S 8 good reasons to choose the milestone DmA-1 1. no sample preparation 2. ease of use 3. lowest cost of analysis
Adsorption and Catalysis
Adsorption and Catalysis Dr. King Lun Yeung Department of Chemical Engineering Hong Kong University of Science and Technology CENG 511 Lecture 3 Adsorption versus Absorption H H H H H H H H H Adsorption
CNE Progress Chart (CNE Certification Requirements and Test Numbers) (updated 18 October 2000)
Novell Education CNE Progress Chart (CNE Certification Requirements and Test Numbers) (updated 18 October 2000) Prerequisite for all certifications In order to receive a Novell certification the candidate
86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories
86 C Freezer Accessories More Choices Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories 2 A Wide Range of Accessories The perfect complement for your
X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software
X-Series Signal Analysis Future-ready instruments Consistent measurement framework Broadest set of applications and software Arrive Ahead with X-Series We can t predict the future, but Agilent can help
PRODUCT DATA. PULSE WorkFlow Manager Type 7756
PRODUCT DATA PULSE WorkFlow Manager Type 7756 PULSE WorkFlow Manager Type 7756 provides a range of tools for automating measurement and analysis tasks performed with Brüel & Kjær PULSE. This makes it particularly
Understanding European versus U.S. temperature code ratings for solenoidoperated. A White Paper From ASCO
Understanding European versus U.S. temperature code ratings for solenoidoperated valves by Manny Arceo A White Paper From ASCO 4 Introduction Solenoid valves are vital components of many process automation
XFA 600 Thermal Diffusivity Thermal Conductivity
XFA 600 Thermal Diffusivity Thermal Conductivity Thermal Diffusivity, Thermal Conductivity Information of the thermo physical properties of materials and heat transfer optimization of final products is
Characterization of Gas Shale Pore Systems by Analyzing Low Pressure Nitrogen Adsorption
Characterization of Gas Shale Pore Systems by Analyzing Low Pressure Nitrogen Adsorption Presented by: Mehdi Labani PhD student in Petroleum Engineering Supervisor: Reza Rezaee September 212 Objective
CHROMOCTANE O N LINE ANALYZER
GECIL Process GT instruments CHROMOCTANE O N LINE ANALYZER ASTM D6733 DHA and RON and MON on line GC for Reformer unit Automatic Chromatographic system for analysis of naphta feeds and reforming gasolines
Inspired Partnership. Software Support Directed by You
Inspired Partnership Software Support Directed by You PARTNERSHIP YOUR GUARANTEE Investing in new test and measurement equipment in today s fast-moving, competitive world is serious business. In addition
Derivation of the BET and Langmuir Isotherms
Derivation of the BET and Langmuir Isotherms October 5, 2011 1 Langmuir Isotherm Assumptions used for the Langmuir isotherm 1. Gaseous molecules behave ideally 2. Only one monolayer forms 3. All sites
Customer Support. Superior Service Solutions for Your Laser and Laser Accessories. Superior Reliability & Performance
Customer Support Superior Service Solutions for Your Laser and Laser Accessories Superior Reliability & Performance Optimizing Service Support for our Customers. Increased up-time Focus on core business
Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations
Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations B e c k m a n C o u l t e r L i f e S c i e n c e s 2 5 0 S. K r a e m e r B o u l e
Toxicity. Toxicity monitoring technologies for on line, on location and the laboratory
Toxicity Toxicity monitoring technologies for on line, on location and the laboratory Contents Microtox M500 page 2 DeltaTox II page 4 Microtox CTM page 6 Technical support page 8 Specifications page 10
AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes
AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S39 management
OCTOBER 2010. Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology
OCTOBER 2010 Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology SEPTEMBER 2010 Russell-Parametric Cross-Sectional Volatility (CrossVol) Indexes Construction
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer Application Note Introduction In a pulsed radar system, one of the key transmitter-side components
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
Agilent P940xA/C Solid State PIN Diode Switches
Agilent P940xA/C Solid State PIN Diode Switches Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any
Multi Tube Rotator. Model No. 4632Q 4632-1CE 4632-1CECN 057-213-00 11/05/11
Multi Tube Rotator Model No. 4632Q 4632-1CE 4632-1CECN 057-213-00 11/05/11 Table of Contents Safety Information...3 Alert Signals...3 Description...4 Specifications...5 Power Requirements...5 Shaker Motion...5
The Global Chemical Industry: US, China and Global Status and Opportunities, 2015
The Global Chemical Industry: US, China and Global Status and Opportunities, 2015 August 28, 2005 American Chemical Society Martha Gilchrist Moore Moore Economics [email protected] Opportunities
PCI Express 1.0 (2.5 GT/s) Protocol Test
PCI Express 1.0 (2.5 GT/s) Protocol Test Configuration and Pricing Guide Gen1 today, ready for Gen2 in the future As PCI Express Gen2 becomes more mature in the market, you must decide whether to continue
HFM Heat Flow Meter Thermal Conductivity Analyzer
HFM Heat Flow Meter Thermal Conductivity Analyzer Introduction An insulating material is a material with low thermal conductivity, which in the construction industry, equipment manufacturing, or the production
Supporting Information
Supporting Information Wiley-VCH 2005 69451 Weinheim, Germany Magnetic Nanoparticle-Capped Mesoporous Silica Nanorod-Based Stimuli-Responsive Controlled Release Delivery System** Supratim Giri, Brian G.
Agilent E363xA Series Programmable DC Power Supplies. Data Sheet
Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation
Accuracy counts! SENSORS WITH ANALOG OUTPUT
Accuracy counts! SENSORS WITH ANALOG OUTPUT OTHER APPLICATIONS: KEY ADVANTAGES: Distance measurement Positioning Profile detection Deformation monitoring Vibration monitoring Process monitoring Detection
CASE STUDY. Environnement S.A. Industrial Site Noise Monitoring
CASE STUDY Environnement S.A. Industrial Site Noise Monitoring France Environmental Noise Monitoring Terminals Environnement S.A., based outside Paris, France, is a cutting edge company in the environmental
Agilent Cary 60 UV-Vis
Agilent Cary 60 UV-Vis Efficient. Accurate. Flexible. Specifications Introduction The Agilent Cary 60 UV-Vis spectrophotometer is efficient, accurate and flexible, and is designed to meet both current
CASE STUDY. Automotive Components. Bosch Drancy, France Brake NVH Testing. Braking Systems. France. Automotive. PULSE, Transducers
CASE STUDY Bosch Drancy, France Brake NVH Testing France Automotive PULSE, Transducers The world-renowned Bosch group is a major producer of a vast range of automotive components. The company is an OEM
Surface Parameters of Stannic Oxide in Powder, Ceramic and Gel Forms by Nitrogen Adsorption Techniques l
PHYSICAL SCIENCES 137 Surface Parameters of Stannic Oxide in Powder, Ceramic and Gel Forms by Nitrogen Adsorption Techniques l JAMES L. RUTLEDGE, Department of Physics OIdahoma State University, StlUwater
POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES
POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES Ecole Nationale Supérieure de Chimie Avenue du Général Leclerc, Campus de Beaulieu 35700 Rennes, France Tel 33 (0)2 23 23 80 02 Fax 33 (0)2 23 23 81
A Complete Solution for Method Linearity in HPLC and UHPLC
Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,