Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S



Similar documents
Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP

Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System

Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, and AXXRPFKSNSH Installation Guide

Intel RAID Maintenance Free Backup Unit AXXRMFBU2 User s Guide

StorTrends 3400 Hardware Guide for Onsite Support

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

Intel Remote Management Module User s Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Replacing the Gateway M675 Keyboard

Intel NUC Kit DC3217IYE User Guide. Intel NUC Kit DC3217IYE

Replacing the Gateway M320 Keyboard

Intel Server System P4000RP Family Service Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products

Intel Storage Server SSR212MC2/ SSR212MC2R User Guide

Hard Disk Drive (HDD)

Upgrading and Servicing Guide

Memory Modules User Guide

Wall-Mounting your HP computer. User Guide

HP ProLiant DL165 G7 Server. Installation Instructions

Intel RAID Maintenance Free Backup Unit AXXRMFBU2 User s Guide

Small form factor bay converter and hard drive installation

Intel SC5100 Pedestal and Rack Server Chassis Subassembly Product Guide

EasyNote TJ Series. Disassembly Manual

Service Guide. Gateway M275

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Inspiron 15. Service Manual Series

ProLiant DL380 Generation 2 Server Maintenance and Service Guide

Inspiron 13. Service Manual Series. Computer Model: Inspiron Regulatory Model: P57G Regulatory Type: P57G001

Packard Bell Easy Repair 1. Packard Bell Easy Repair

This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

Processor Cage Fans, Front and Rear Replacement Instructions

Dell Inspiron 660s Owner s Manual

MegaRAID LSIiBBU09 Intelligent Battery Backup Unit

HP SATA/SAS hard drive and Solid State Drive installation

Front Panel Board Cable Replacement Instructions

SERVICE GUIDE. Gateway Notebook

HP 22-in-1 Media Card Reader

MegaRAID LSIiBBU08 Intelligent Battery Backup Unit. Quick Installation Guide

HP Optical Bay Hard Drive Bracket

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide

UPGRADING AND SERVICING GUIDE

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Intel Server Board S5520HC, S5520HCT and S5500HCV Service Guide

To view this information... Installing additional tape drives page 5 Replacing a tape drive with the same configuration

Installing your upgrade processor

Acer Aspire One AOA Disassembly

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

5800 Temperature Sensor Cable Assembly

PS6500 Storage Arrays Rack Mount Instructions

HP Laser Jet 2400 Series Fixing Drive Side Plate Assembly Fixing Drive Side Plate Assembly- RM page 1

Refer installation of power supplies to qualified service personnel.

Installing Your 960 or 980 Server into a Rackmount Cabinet

Installation Guide. Wyse C Class 2-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

Packard Bell Easy Repair

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Elecraft K3 KPA3 Power Connector Replacement Revision A Review, April 16, 2012 Copyright 2012, Elecraft, Inc. All Rights Reserved

Accessing the printer system board

Intel Technical Advisory

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: PN: L Rev.

GSM-EXT Cable Assembly Installation Guide

Removable 2.5 SATA HDD Backup System

REMOVE AND REPLACE AIR CONDITIONER. 170 Popular Dodge REMOVAL: AIR CONDITIONING Section 4 Page 1

HP LaserJet MFP Analog Fax Accessory 300 Fax Guide

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

BladeRunner 4U Blade Server User Manual. December 2004 (Revision A)

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer.

Intel Gigabit Ethernet Switch AXXSW1GB User Guide A Guide for System Administrators of Intel Server Products

430 Power/Electronics Replacement

MAXDATA PLATINUM Blade Server. User s Manual

HP UPS R1500 Generation 3

SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

Intel Server System S7000FC4UR

Removing memory and option cards

Dell Inspiron XPS and Inspiron 9100 Service Manual

Memory Installation Guide

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

SanDisk Solid State Drive

Tyan Computer. Transport PX22. Service Engineer s Manual

Dell E Series Monitor VESA Mounting Bracket Installation Instructions

Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

Intel Entry Server Chassis SC5275-E

Trusted Platform Module (TPM) Quick Reference Guide

Intel Server System SC5650HCBRP Service Guide

8800 Series VAC PSU XCM88PS1

Rack Installation Instructions

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

HP Integrity rx2660 Server Installation Guide

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

Transcription:

Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number: E13860-004

Disclaimer Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice. Intel server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits. Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright 2007-2008, Intel Corporation. All Rights Reserved ii Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S

Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel Server Deployment Toolkit CD and/or at: http://support.intel.com/support/motherboards/server/sb/cs-010770.htm Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der Intel Server Deployment Toolkit CD oder unter: http://support.intel.com/support/motherboards/server/sb/cs-010770.htm Consignes de sécurité Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel Server Deployment Toolkit CD ou bien rendezvous sur le site: http://support.intel.com/support/motherboards/server/sb/cs-010770.htm Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel Server Deployment Toolkit CD y/o en: http://support.intel.com/support/motherboards/server/sb/cs-010770.htm 重 要 安 全 指 导 Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S iii

Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold. System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components. Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result. Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts. ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. iv Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S

Contents Safety Information... iii Important Safety Instructions... iii Wichtige Sicherheitshinweise... iii Consignes de sécurité... iii Instrucciones de seguridad importantes... iii Warnings... iv Backup Battery Kit Install Guide... 1 Tools Required...1 Kit Contents...1 Backup Battery Kit Installation Instructions...1 Prepare System... 1 Remove Storage Controller from System... 2 Remove Top Cover from Storage Controller... 3 Remove Old Backup Battery...4 Install New Backup Battery... 5 Re-install Top Cover... 5 Install Storage Controller in System...6 Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S v

vi Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S

Backup Battery Kit Install Guide Tools Required Phillips* screwdriver Kit Contents Backup Battery Kit (MFSCMBBU) Item Quantity Backup Battery 1 Install Guide 1 Backup Battery Kit Installation Instructions Prepare System 1. Read all caution and safety statements listed in this document before performing any of the steps. See the Intel Server Boards and Server Chassis Safety Information document at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm for a complete listing of all caution and safety statements. Caution: Before performing any maintenance on the system, back up the data. Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S 1

Remove Storage Controller from System 2. Press the retention lever latch button to release the retention lever (see letter A in the following figure). Rotate the lever out and away from the module bay (see letter B ) and pull the storage controller straight out the back of the chassis (see letter C ). Warning: You must replace the storage controller with a filler panel or another temporary storage controller within two minutes. C A B AF002430 Figure 1. Removing Storage Controller from System 2 Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S

Remove Top Cover from Storage Controller 3. Place the storage controller sideways on a work surface so that it s largest surface area is touching the work surface and the extraction lever is on the top. 4. With a Phillips* screwdriver, remove the single screw located at the front edge of the top cover (see letter A in the following figure). Slide top cover towards rear of storage controller (see letter B ) and lift upward to remove (see letter C ). B A C AF002563 Figure 2. Removing Top Cover from Storage Controller Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S 3

Remove Old Backup Battery Warning: Dispose of used backup battery in accordance with manufacturer s instructions. 5. Disconnect battery cable from battery connector on the printed circuit board (see letter A in the following figure). Remove old backup battery from black plastic battery holder (see letter B ). B A AF002469 Figure 3. Removing Old Backup Battery 4 Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S

Install New Backup Battery 6. Install the backup battery in the black plastic battery holder (see letter A in the following figure). Connect the battery cable to the battery connector on the printed circuit board (see letter B ). A B AF002440 Figure 4. Installing New Backup Battery Re-install Top Cover 7. Align notches in top cover with corresponding tabs on storage controller. Slide top cover forward to close. 8. Secure top cover to storage controller with the single screw previously removed. Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S 5

Install Storage Controller in System 9. Remove filler panel or temporary storage controller if necessary. 10. Ensure the retention lever is out and away from the storage controller (see letter A in the following figure). Slide the storage controller into the module bay (see letter B ) until the bottom of the retention lever engages with the module bay. B A AF002412 Figure 5. Re-installing Storage Controller in System 6 Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S