CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION



Similar documents
Requirements for the Attachment of Communication Cable Facilities on PPL Poles

STREETLIGHT SYSTEM GROUNDING AND BONDING

IRRIGATION PUMPING Table of Contents - Section 900

Please check with your local inspection authority for any additional requirements before installation.

June July 18, of 7

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Chapter 9. Bonding and Grounding

Hyperlinks are Inactive

How To Get A Power Line Extension

Video Camera Installation Guide

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

Specifications for Lightning Protection. ASAE Engineering Practice

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

No Phone Line II-48 System

Customer Substation Manual 08/05/02

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

Services. Three Phase Service

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

Electrical Grounding. Appendix C

Grounding & Bonding Why it is done And How to Install Properly

ELECTRIC SERVICE HANDBOOK General Information Residential Service Portable/Standby Generators Temporary Service Commercial Service Metering

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

Security Cameras, CATV, GPS & Satellite Protection. White Paper

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Solar Panel Installations

800 Communications Circuits

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

GroundRod AC Substation Earthing Tutorial

8. Work Area Protection

SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

CUSTOMER REQUIREMENTS AT POWER SUBSTATIONS

Electrical Code Regulation

Application of Four-Pole Circuit Breakers within Data Centers

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

How To Wire Wire Wire For A Decoder System

Pole Attachment Guidelines and Procedures Revision September 2015

Earthing Guidance Notes

C ole s quality Open Frame Instrument Rotary Switch provides low

Electric Service Guide for Residential Construction

GROUNDING AND BONDING ELECTRICAL SYSTEMS

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

4. REQUEST FOR ELECTRIC SERVICE. 4.1 General Service Information

BASIC NEC CODE RULES AND DESIGN PRACTICE

Operating Instructions

CARROLL COUNTY ELECTRICAL DEPARTMENT SERVICE POLICIES. EFFECTIVE MARCH 1, 1995 Revised 1/01/2013

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

When power interruptions happen.

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

NEC 2014 Code Changes

2.4 kv to 34.5 kv SP-1099

TABLE OF CONTENT

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

3M Quick Connect System (QCS) 2814

Grounding Practice at Data and Communications Centers. David Brender, P.E., CPQ National Program Manager Copper Development Association Inc.

ELECTRICAL SAFETY Information Bulletin

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

CITY OF LOS ANGELES CALIFORNIA

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

Extension Cord Safety Policy

City of Riverside Building & Safety Division Phone: (951)

David Brender Copper Development Association Inc. Miramar, March 8, 2013

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

Wellesley Municipal Light Plant. Standard Requirements for Electric Service

I = V/r P = VI. I = P/V = 100 W / 6 V = amps. What would happen if you use a 12-volt battery and a 12-volt light bulb to get 100 watts of power?

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

Interface between Eircom Network and Additional Telephone Equipment

ELECTRIC SERVICE HANDBOOK

PXL-250: Network Wiring

Underground Service Requirements and Instructions

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

2012 Edition Redbook 11.0 GENERAL DRAWINGS AND STANDARDS

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Electric Service Guide for Commercial Construction

Electric Service Standards

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

OVERHEAD SERVICE. Table of Contents - Section 400

DPS Preliminary Review: Verizon FIOS Customer Premises Installation NEC Compliance Issues

Memphis Light, Gas and Water. ELECTRIC, GAS AND WATER Schedule of Charges

How Much Voltage Drop Is Acceptable?

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Cable and Pipe Locating Techniques

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

GUIDELINES HAS/PDC/DESIGN DIVISION TITLE

County of Riverside Building and Safety Department

Transcription:

Page 1 of 11 ****This Standard Supercedes BECo CS2.13-2.3 & ComElectric OH Construction Manual, System Grounding Section, drawings CGND, GRDSUM, and C2**** 1.0 Bill of Materials GROUNDING AND BONDING POLE-MOUNTED EQUIPMENT Item Description Stock Symbol 1 Wire, ground #4 copper covered 120 2 5/8 x 8 sectional ground rod, threaded at both ends. 9229 3 Molding, ground wire 833 4 Staple, ground wire molding 9332 5 Ground rod coupling, 5/8 x 2 10234 6 Copper Pole Butt Plate, 7 diam. 9200 7 Staples (fence) to secure wire to pole 6341 8 Ground rod driver, fits 5/8 and 3/4 ground rods. Use 15450 in conjunction with Cat ID # 15295 9 Ground rod driving cap, fits 5/8 and 3/4" ground 15295 rods. Use in conjunction with Cat ID # 15450 10 Ground rod connector, range #8 solid 1/0 stranded 9009 copper. 11 Wire, tinned # 4 solid copper 114 12 1/0 AWG polyethylene covered stranded copper wire 123 13 Ground resistance tester (if needed) 15892 2.0 Procedure 2.1 Use this procedure for updated bonding and grounding requirements for distribution equipment, to comply with the National Electric Safety Code. Low resistance earth grounding is essential to provide the level of protection required to protect personnel, equipment, and the public from shock hazards. Proper grounding will provide a more stable system with a minimum of transient over voltage and electrical noise. Proper grounding will also provide a path to ground in fault conditions and protection from large electrical disturbances (such as lightning) by creating a low resistance path to earth.

Page 2 of 11 2.2 Grounding Pole-Mounted Equipment on Grounded-Wye System. A. All equipment cabinets, tanks, frames, and mounting brackets shall be grounded to the system neutral. B. Surge or lightning arrester ground terminals should be connected with the shortest, most direct path to earth/ground. C. Transformer mounted arresters are connected directly to the grounded tank. D. Any new or upgraded pole-mounted equipment, except for streetlights, will be connected to the existing system neutral. A new ground rod will be installed if one does not already exist at the pole. E. All new equipment poles require a butt plate and a ground rod. Switch handles, streetlight fixtures, down guys, and transformer secondaries must be properly grounded. F. The system neutral shall be connected to any grounding that exists on a distribution pole. G. Grounding equipment will protect people from energized wires that are no longer properly insulated for their voltage. 2.3 Pole Grounding Butt Plate Requirements. A. All new poles that will support electrical wire or cable shall have a minimum #4 copper wire pole down ground installed. Before the pole is set in the ground, that wire shall be connected to a copper pole butt plate with a mechanical connector. That wire shall be stapled along the pole to a point just above ground level, where it will be secured as a small coil. After the pole is set, the wire shall be uncoiled and connected up to the system neutral, and any messenger cable, if present. B. The pole butt plate is not a substitute for a driven ground rod. If a new pole is to have any equipment requiring a ground rod, then one or more shall be installed as required elsewhere in this document. 2.4 Ground Rod Requirements. A. Drive ground rods four (4) inches below the finished surface. Ground rods must be driven into undisturbed soil at a minimum distance of twelve to eighteen inches from the pole. If the pole setting foam is used, the ground rod must not be encased in this foam Be sure dig safe markings are clearly visible in the area. Where rocky soil or other field conditions prohibit driving ground rods to a depth of eight (8) feet, install additional ground rods at adjacent poles.

Page 3 of 11 B. Where practicable, a reading of 25 ohms or less between the downground and the earth is desired. If you are in an area where the soil conditions are highly resistive, (sandy, dry, less than ideal soil conditions ) install an additional ground rod above the first, resulting in a 16-foot driven ground. When rocky soil or other conditions prohibit driving ground rods to 16 feet, install the additional rod adjacent to the first no closer than six (6) feet to any existing rod, and connect rods with a bare #4 copper wire. See Figure 2. C. For both open wire and spacer cable overhead installations, install ground rods at all pole locations having transformers, switching devices, disconnects, sectionalizers, reclosers, voltage regulating devices and/or lighting arrestors, at all dead-ends, and at all riser poles. For spacer cable construction, install ground rods at every pole. D. Bonding Requirements 1) Bonding conductors shall be bare tinned copper wire or covered copper wire. 2) Minimize joints in bond wires. If joints are unavoidable, use compression or solder connectors. 3) Use bonds as a permanent connection between otherwise isolated circuits and/or equipment to equalize potentials. When bonding conductors are in direct contact with the earth, the wire MUST be covered. 2.5 Pole Installations. A. Attach #4 pole down grounds to driven ground rods in accordance with Figures 2 and 3 when a continuous metallic underground system is not available. B. Terminate the down grounds from pole mounted equipment to the common neutral as shown in Figure 3, providing a disconnect point to safely remove grounds when required to perform work on the pole. C. Power risers Pole grounds shall be upgraded to 1/0 copper size from the ground rod to the system neutral and up to the primary area grounds.

Page 4 of 11 3.0 Intercompany Bonding Intercompany grounding/bonding requirements as defined in the National Electric Safety Code (NESC), the Joint Ownership (JO) agreements, and the Intercompany Operating Procedures (IOP s) between the company and communication companies follow. Communication lines and communication company messengers include (by NESC definition) all lines used for public or private signal or communication service. Included are telephone, telegraph, railroad signal, fire and police alarms, cable television, and various other nonelectrical supply lines. 3.1 Electric supply and communication systems shall be bonded together in accordance with NESC requirements. The purpose of bonding is to reduce the possibility of electric shock and minimize plant damage in the event of accidental contact. 3.2 Overhead NESC Rule 097G defines the required bonding between communication systems and electric supply systems on joint use poles. a) If a single pole ground is used, it must be connected to both the supply neutral and the communication messengers. b) If separate pole grounds are run to the supply neutral and the communication messengers, the pole grounds must be bonded together. c) If isolation is being maintained between the primary and the secondary neutrals, such as for stray voltage, the communication messengers shall be connected only to the primary grounding conductor. 3.3 Underground NESC Rule 384C requires that above ground metallic power and communication apparatus such as pedestals or transformer cases that are six feet or less apart be bonded together. A bond is not required if the separation is greater than six feet. See Figure 1.

Page 5 of 11 Figure 1 NESC reference Rule 97G refers to bonding of communication systems to electric supply systems where all systems on the pole are grounded on a joint use structure. A single grounding conductor shall be used for all systems or the electric and communication grounding conductors shall be bonded together. An exception to this rule is where separation is required by Rule 97A. This rule requires the electric supply utility to maintain isolation between primary and secondary neutrals; the communication system ground shall be connected only to the primary grounding conductor. Typical installations are outlined in Figure 4.

Page 6 of 11 Figure 2 - Installations of Ground Rod and Butt Plate at Pole. Note: 1. Staple moulding to pole 12-inch spacing. Moulding must clear metal equipment by 1-1/2 inches (minimum). 2. High vandalism (copper theft) areas require that fence staples spaced 12 indoor Apart be used on the 8ft. of wire in the pedestrian area. Over that install moulding with staples also spaced 12 inches apart, but staggered with the fence staples.

Page 7 of 11 DOWN GROUND COMMON NEUTRAL MECHANICAL CONNECTION- CONTINUOUS DOWN WIRE (TYP) CATV TELEPHONE TO GROUND ROD GROUND LINE END BENT OVER 1 3 END OF MOLDING MUST BE 4 INCHES BELOW GRADE 2 GROUND ROD TO BE INSTALLED IN UNDISTURBED SOIL 12" - 18" 5 2 Figure 3 - Down Ground Connections. Note: If pole mounted equipment must remain grounded (i.e., single bushing transformers and SCADA-MATE switches) make the equipment ground a permanent connection to the common neutral.

Page 8 of 11 Figure 4 Grounding of Overhead Transformers on Ungrounded WYE and Delta Circuits.

Page 9 of 11 4.0 Grounding for Delta Primary System Transformers, NSTAR South Only 4.1 A delta primary system does not use a primary neutral wire, and is not considered a multigrounded system. Therefore, the grounding of polemounted equipment on delta systems requires special attention. Surge arresters must be grounded through a dedicated ground wire and rod located at the same pole. Transformer tank, frame or any bracket ground connections will be made to the arrester ground circuit. In delta circuits, the secondary neutral must not be interconnected with this arrester/ equipment ground circuit. 4.2 To meet the National Electric Safety Code (Rule 97D), two ground rod assemblies separated by at least twenty (20) feet must be installed for each transformer/arrester location. This will reduce the chance of a surge passing through the arrester affecting the secondaries. Delta circuits do not have as many ground paths for lightning surges like in a grounded wye system. 4.3 To meet the NESC requirement, it is necessary to connect any arresters directly to a driven ground rod on the same pole. Separate the arrester/tank ground from the secondary neutral by removing the tank ground strap from the (Xo) bushing. Then, the secondary neutral wire (triplex or open wire) connected to that neutral bushing will be run to a pole ground and driven ground rod assembly at the next closest pole. There should be no arresters installed on this pole. 4.4 Ground rods in delta systems, where practical, will have a maximum earth ground resistance of 25 ohms (Ω). In high resistance areas, two (2) sixteen (2x8 ) foot rods are to be installed together in an inverted V arrangement, {see Figure 4}. This inverted V separates the ground rod points for maximum benefit 4.5 Guy Insulators: In delta systems, a guy insulator will be installed so that even if the guy wire breaks at the anchor attachment, the freehanging insulator will stay at least eight (8) feet above the ground. Guy wires in delta systems do not need to be bonded to the neutral (grounded) because of the insulator.

Page 10 of 11 LIGHTNING ARRESTER TANK GROUND DO NOT CONNECT TANK GROUND TO NEUTRAL NOT TO SCALE SECONDARY NEUTRAL TRANSFORMER POLE WITH ARRESTER GROUND ADJACENT POLE WITH NEUTRAL GROUND GRADE LEVEL 4" MIN DEPTH GROUND RODS 30 30 GROUND RODS 30 30 Figure 4 - NSTAR South Only - Transformer Grounding for Delta Primary with no Primary/System Neutral NOTES: A. For areas that do not have a multigrounded primary system, the National Electric Safety Code (Rule 97D) requires that the arrester ground rod and neutral ground rod be separated by a minimum of twenty (20) feet. This standard drawing complies with that requirement. B. Dig-Safe must be notified before any ground rods are installed. C. Transformer mounted arresters are normally grounded to the tank. The pole ground wire of that pole must then be connected to that tank ground. Do not tie in to the neutral bushing or wire that will be grounded at the next pole.

Page 11 of 11 D. Remove the ground strap that normally would connect the X (neutral) bushing of the transformer to the tank. E. A neutral wire is to be installed to (if none exists) and grounded at the next closest pole. This neutral may be open wire copper or triplex cable. The adjacent pole must not have any arrester grounding on it already. F. Any other equipment such as capacitor bank arresters, riser arresters, frames, brackets, and URD cable concentric ground wires will be connected to the ground wire/rod assembly of the pole they are mounted on. G. In delta circuit areas, a ground wire molding should be installed all the way up the pole to the transformer. Communication companies should bond to the neutral that is grounded at the adjacent pole. H. The ground rods are installed in an inverted V arrangement to maximize the separation of the rod tips. Install the rods opposite to each other at about a 30 angle off of a vertical line. Normal ground resistance areas require using only eight (8 ) foot rods, which will have tips about 8 apart at their deepest point. In high soil resistance areas, use two eight-foot ground rods installed the same way. Install the rods in the direction of the overhead wires. Review by: Approved by: Amin Jessa Director, Safety and Health Director, Distribution Engineering