3M Quick Connect System (QCS) 2814
|
|
|
- Emily Bishop
- 10 years ago
- Views:
Transcription
1 Communication Markets Division 3M Quick Connect System (QCS) 2814 Designed for your broadband network The 3M Quick Connect System 2814 is a terminal/cross-connect system featuring integrated protection from 3M. The QCS 2814 is a simple-to-use copper block; an ideal solution for indoor applications or a controlled environment. The QCS 2814 block description denotes standard 2810/2811 components along with a factory-installed protection interface. 3M Quick Connect System (QCS) 2814 with jumper wire inserted New demands in an age of information Every day, local loop providers work to provide enhanced customer services such as data access with faster Internet transmission, video-on-demand and video conferencing. Many providers are deploying ADSL2+ & VDSL2 over twisted pair copper cable to meet these demands. As new technologies migrate into the local loop, the importance of connections in the embedded plant increases. 3M provides connectors you can trust. Features Tool-less jumpering Visibility to jumpers Telcordia GR-3154 performance Pair-at-a-time termination Low termination force Protected connector *2814-B System Only Benefits Simple termination practices increases technician productivity Ability to inspect jumper termination allows validation of connection, minimizing rework Reliable high-speed data transmission exceeding VDSL2 frequencies Increases craft productivity Craft-friendly, tool-less design* Line can be placed in service only when the protector is placed onto the base of the block
2 View of the base with integration strip of the 3M Quick Connect System (QCS) 2814 Integrated Protection Block 3M Protector for the 3M Quick Connect System (QCS) 2814 Integrated Protection Block As you like it The 3M Quick Connect System (QCS) 2814 is available in models and frames to meet your application needs. The QCS 2814 is modular in design. Termination blocks are available for pre-terminated applications in a 50-pair block or field-terminated applications in a 10-pair strip. In field-terminated applications, the block is capable of terminating cable-side either with thumb actuation or with a convenient punch-down tool for increased productivity. The QCS 2814-A or 2814-B versions are not configured with the protectors, which are ordered separately but are needed to complete the customer service connection. 3M Quick Connect System (QCS) 2814-A Block (left) and 2814-B Block Field cable termination options The 3M Quick Connect System 2814-A: A 10-pair strip utilizing an IDC punch down tool to insert the cable wire into the back-side IDC element and trim the wire in one motion. This tool increases craft productivity in the installation of a cabinet, allowing the craftsperson to prepare all ten cable pair that go to a given block and then to follow along with the tool and insert each wire in short order. Once the block is cabled and placed on the frame, the jumpering is completely tool-less. The 3M Quick Connect System 2814-B: A 10-pair strip with completely tool-less termination. In this strip, the ergonomic jumper caps are located on the cable side as well as the jumper side allowing for tool-less termination of the cables and tool-less jumpering. All terminations are pair-at-a-time. Over-voltage protection of equipment Lightning is not the only potential cause of damage to network equipment. Direct or indirect contact between power and telecommunications cables, known as power cross, can also pose a threat to equipment and personal safety. 3M Quick Connect System (QCS) 2814-B Blocks installed on a frame 3-point protection QCS 2814 blocks can be protected with a heavy-duty 3-pole gas discharge tube featuring a fail-safe device. The 3-point protectors handle large voltage spikes commonly generated by lightning surges and in case of lasting surge, the fail-safe device will provide a path for the voltage to earth. These protection solutions for the QCS 2814 modules are available in single-pair protector modules. 3M Quick Connect System (QCS) 2814 Frame
3 Applications The 3M Quick Connect System (QCS) 2814 can be used throughout the network as the common interconnectivity and termination platform. Designed specifically for rugged use and robust performance in building entrance terminals. 3M Quick Connect System 2814 Mechanical Specifications Dimensions: Height Width Depth* 50-pair block (on frame with 3-point protector) 38 mm / 1.5" 135 mm / 5.31" 26 mm / 1.02" Wire range IDC contacts solid copper conductor 0.4 mm to 0.6 mm 26 AWG to 22 AWG Wire re-terminations: 250 re-terminations of 24 AWG per Telcordia TR-NWT Electrical: Insulation resistance: Contact resistance: Dielectric strength: High voltage surge: >1x10 10 Ω < 10 mω 3000 V rms, 60 Hz AC 3000 V DC Surge Broadband Telcordia GR-3154 High speed digital network component compliant Environmental Operating temperature range -20 C to 60 C Storage temperature range -40 C to 90 C RoHS: Compliant with EU RoHS Directive (2011/65/EU) Materials: Plastics: Contacts: Thermoplastic Bronze, Tin (Sn) plating
4 Ordering Information Product Number Product Description 3M ID Min. Order FRAMES AND HARNESSESS 2811F100-30P QCS Frame, 30 mm pitch, 100-pair F100MB Wall-mount brackets for QCS frame XPH-QCSHC/25/24 DPMFR QCS harness XP Pair with 3M MS2 DPM module XPH-QCSHC/25/24 SD QCS harness XP Pair with 3M 710 SD module XPH-QCSHC/50/24DPMFR QCS harness XP Pair 1-50 with 3M MS2 DPM module XPH-QCSHC/50/24SD QCS harness XP Pair 1-50 with 3M 710 SD module SPD-3-350V Single pair protector (dry), 3-point, 350 V ACCESSORIES 2814GB Ground Bar Assembly for QCS 2814 XS LT-BLGR QCS tagging labels (blue/green), LT-BLGR QCS tagging labels (blue/green), LT-BLGR QCS tagging labels (blue/green), PC-P Purple priority cap XS PC-R Red priority cap XS PC-Y Yellow priority cap XS RC-0 Orange replacement cap XS RC-P Purple replacement cap XS Single-pair test probe XS P Single-pair test probe pocket size XS PC Pair Cover XE HT Termination hand tool IDC small XS CA SOR OC PKSI-S IDC Termination Tool FQ C234056A SOR OC SI-S IDC Insertion Hand Tool FQ
5 RoHS 2011/65/EU means that the product or part does not contain any of the substances in excess of the maximum concentration values ( MCVs ) in EU RoHS Directive 2011/65/EU. The MCVs are by weight in homogeneous materials. This information represents 3M s knowledge and belief, which may be based in whole or in part on information provided by third party suppliers to 3M. 3M and MS 2 are trademarks of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of 12 months from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether indirect, special, incidental or consequential regardless of the legal theory asserted. Communication Markets Division 6801 River Place Blvd. Austin, TX USA Phone Fax Web 3M.com/Telecom Please recycle. Printed in USA 3M All rights reserved
3M Integrated Splitter Block BRCP-SP
The Network of Networks 3M Integrated Splitter Block BRCP-SP The 3M Integrated Splitter Block BRCP-SP is the latest generation of the Cross Connect System BRCP developed by 3M specifically for xdsl and
3M Quick Connect System (QCS) 2810 Models 2810A and 2810B
3M Quick Connect System (QCS) 2810 Models 2810A and 2810B Instructions October 2010 3 Contents 1.0 General...3 2.0 Recommended Installation Procedure for 3M Quick Connect Systems 2810A and 2810B...3 3.0
Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C
M I/O Interconnect System 2.0 mm for IEEE 194 Wiremount Receptacle (Female) E206 Series Designed to mate to all M I/O Interconnect System 2.0 mm for IEEE 194 Boardmount Plugs Polarized to provide proper
Expanding a 40-Type Cabinet
Expanding a 40-Type Cabinet using the 3M Add-On Terminal 4220P 400-Pair and Jumper Trough Instructions January 2006 Table of Contents 1.0 General... 3 2.0 Cabinet Overall Descriptions... 3 3.0 Tools Required...
Scotchlok Connectors and Tools
Scotchlok Connectors and Tools Proven Solutions For Today s Applications A New Series of Tools and Connectors from 3M. 50 years ago, 3M introduced the industry s original insulation displacement connector
3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series
M High Flex Life Cable.050" 28 AWG Stranded, PVC 19 Series Flex life of 100 million cycles at 1 /4 inch diameter 19 strands of high strength copper alloy provide the longest flex life available for dynamic
3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series
M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series Wires are color-coded for easy identification Twist and flat repeat has variable length option Can be mass terminated
Cables and Accessories Selection Guide
Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an
Gas Discharge Tubes GTCX26-XXXM-R05 Series
Raychem Circuit Protection 6mm 2Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data transmission lines
3M Pin Strip Header Single and Dual Row.100,.235 /.318 Mating Length, Straight & Right Angle, Solder Tails 929 Series
M Pin Strip Header Single and Dual Row.100,.25 /.18 Mating Length, &, Solder Tails 929 Series Stackable Gold, Matte Sn, or -Lead plating options High Temperature (PCT) plastic for Wave or IR soldering
3M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series
M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series Stackable Tin Lead or gold plating available Solder stand-offs facilitate production wave soldering Board pin
3M Serial Attached SCSI (SAS) Connector Boardmount Compliant Pin and Surface Mount, Vertical Receptacle
M Serial Attached SCSI (SAS) Connector 6 Gbps input/output connector for backplane applications Two contact mating levels for early-mate and latebreak allows blind mating or hot swap applications Capable
Gas Discharge Tubes GTCX36-XXXM-R05 Series
GTCX36-XXXM-R05 Series TE Circuit Protection 6mm 3Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data
SUPERSEDED REVISION. Gas Discharge Tubes GTCX28-XXXM-R20 Series. Features: Benefits: Applications
GTCX28-XXXM-R20 Series Raychem Circuit Protection 8mm 2Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and
Gas Discharge Tubes GTCX38-XXXM-R10 Series
GTCX38-XXXM-R10 Series TE Circuit Protection 8mm 3Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data
3M Dynatel Triple Play Customer Service Test Set INS970
3M Dynatel Triple Play Customer Service Test Set Advanced Diagnostics Software Options DELT, SELT and Spectral Analysis The Test Set has the ability to run advanced diagnostics in different scenarios to
3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series
M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series Wiper-on-wiper contact for reliable repetitive plugging Ultra-low signal skew for high data rate transmission
Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer
3 Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer DSL User s Guide Future-Proof Testing Platform February 2009 78-8140-2658-5-A 2 3M Dynatel Advanced Modular System 965AMS 30-MHz
3M Pin Strip Header 2 mm 2 mm Solder Tail Straight & Right Angle, Surface Mount Straight 1512 Series
M Pin Strip Header 2 2 Solder Tail Straight & Right Angle, Surface Mount Straight 1512 Series Mates with a variety of dual row 2 board mount and wire mount sockets High temperature insulator compatible
Ethernet Cat 5e & Cat 6 Patch Panels
Ethernet Cat e & Cat Patch Panels Copper :: RJ/IDC Models EPPE-CTE & EPPE-CAT User Manual Applys to : EPPE-CTE :: EPPE-CAT Telect, Inc., All Rights Reserved, 9- A0.09.9.000 :: telect.com Ethernet Cat e
3M xdsl Line Conditioners 3620
3M xdsl Line Conditioners 3620 Instructions 1.0 General 1.1 Document Purpose This document provides general and installation information necessary to install the 3M xdsl Line Conditioner. 1.2 Description
3M Scotchcast Mine and Portable Cable Splice Kit 8096-4
3M Scotchcast Mine and Portable Cable Splice Kit 8096-4 Installation Instructions 1.0 Kit Contents: 2 Funnels 3 EPDM Rubber Cold Shrink Cold Shrink Insulator 1 Wrap-around Mold Assemblies 2 Rubber Mold
Directory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.
Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s
INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION.
CONNECTORS 2014 INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION. Stelvio Kontek S.p.A. is one of the leading groups in the connectors market. With a solid background in the sector and having
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS
. HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or
FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON
FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON SERIAL NUMBER Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 (615) 261-2000 Front Matter Abstract This
Advanced Systems Tester 900AST
Advanced Systems Tester 900AST Clear skies ahead with the 900AST TESTER The internal wiring in aircraft is under constant bombardment from age, vibration and moisture especially in airplanes that work
3M Electrically Conductive Adhesive Transfer Tape 9703
Technical Data April 2011 M Electrically Conductive Adhesive Transfer Tape 970 Product Description M Electrically Conductive Adhesive Transfer Tape 970 is a pressure sensitive adhesive (PSA) transfer tape
How To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
3 740 Wrist strap + shoe tester
3 740 Wrist strap + shoe tester Operating Instructions April, 2001 740 wrist strap + shoe tester 3 < o.k. > 1 2 1 / 11 LED for «too w resistance» 740 wrist strap + shoe tester 3 < o.k. > 1 2 LED for «too
SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version
Now Available in 1 Position Free Hanging Version SlimSeal SSL Connector The SlimSeal SSL connectors are low profile, single row connectors developed for indoor and outdoor LED lighting applications. These
Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable
Fiber Optic Cable Assemblies Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable 1 Cable assemblies used in patch panels (Fiber Distribution Units) are an essential interface
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
SC Series: MIS Chip Capacitors
DATA SHEET SC Series: MIS Chip Capacitors Applications Systems requiring DC blocking or RF bypassing Fixed capacitance tuning element in filters, oscillators, and matching networks Features Readily available
XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement
Flat Cable Connectors for PCBs XG2 Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring IDC connections allow you to wire all terminals at once without terminating the cable. Can
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
Quick Reference Guide Euro Style Terminal Blocks
Quick Reference Guide Euro Style terminal block connectors feature various wire termination methods including rising cage clamp, wire protector, spring, IDC and crimp snap. The design of terminal block
3M Scotchcast Electrical Resin 251 Two-Part, Oven-Curing, Class F, Rigid, Filled, Epoxy Liquid Resin
3M Scotchcast Electrical Resin 251 Two-Part, Oven-Curing, Class F, Rigid, Filled, Epoxy Liquid Resin Data Sheet April 2013 Description 3M Scotchcast Electrical Resin 251 is a medium viscosity, rigid, Class
3M Wire Connectors. Reliable, high performing solutions for every wire connecting application. 3Innovation
3M Wire Connectors Reliable, high performing solutions for every wire connecting application. 3Innovation SAVE TIME, REDUCE INVENTORY YOU CAN NEVER BE TOO WELL-CONNECTED ON THE JOB The best connectors
BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors
C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution
Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
About the BitStorm 6051 POTS Splitter
BitStorm 6051 Installation Instructions Document Number 6051-A2-GZ40-10 July 2002 About the BitStorm 6051 The BitStorm system enables simultaneous high-speed digital data access and analog voice service
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
HARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Nest Learning Thermostat Installation Guide. Installation step-by-step
Nest Learning Thermostat Installation Guide Installation step-by-step Contents Compatibility. 3 In the box. 4 Before you start. 5 Choose an installation method. 6 Replacing an existing wired thermostat.
USB 3.0 PCI Express. 2-Ports Host Controller Card. User Manual. www.hamletcom.com HUSB302PCX
USB 3.0 PCI Express 2-Ports Host Controller Card User Manual HUSB302PCX www.hamletcom.com Index 1. INTRODUCTION... 4 2. INSTALLATION... 5 2.1. HARDWARE INSTALLATION...5 2.2. DRIVER INSTALLATION (WINDOWS
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Scotch-Weld PUR Easy 250 Adhesive Applicator
Scotch-Weld September, 2014 Product Description PUR Easy 250 Applicator is a self contained pneumatic applicator designed to dispense 1/10 th gallon(300ml) cartridges of 3M PUR adhesives. PURs are a family
1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) High insulation Insulation distance (between coil and
FTTX Solutions FDH 3000 Cross-Connect
TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
EMI Shielding Tapes Product Selection Guide. Trusted. Performance. from the. Tape Experts
EMI Shielding Tapes Product Selection Guide Trusted Performance from the Tape Experts 3M EMI Shielding Tapes A wide variety of tapes for EMI shielding and grounding Copper, aluminum, and tin-plated copper
1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C
FTR-K1 SERIES POWER RELAY 1 POLE - 16A / Inrush 120A relay FTR-K1-KS Series FEATURES 1 pole 16A, 1 form A or 1 form C Peak inrush current 120A / TV-8 Coil power 400mW High insulation in small package (between
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION
Page 1 of 11 ****This Standard Supercedes BECo CS2.13-2.3 & ComElectric OH Construction Manual, System Grounding Section, drawings CGND, GRDSUM, and C2**** 1.0 Bill of Materials GROUNDING AND BONDING POLE-MOUNTED
MTV-FS1 / FS1T / FSB375
MTV-FS1 / FS1T / FSB375 MYE Entertainment Freestanding LCD TV Floor Stand with Base Assembly Instructions man_mtvfs1_b3 www.myeclubtv.com Table of Contents Parts List 3 Parts Identification......3 Hardware
Intersection Preassembled 19-inch Rack
Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES
FTR-K1 SERIES MINIATURE RELAY 2 POLES - 1 to 2 A (For Signal Switching) NA Series FEATURES Slim type relay for high density mounting Conforms to Telcordia specification and FCC Part 68 - Dielectric strength
Dynatel 2273 Advanced Cable and Fault Locator
Dynatel 2273 Advanced Cable and Fault Locator Operators Manual September 1999 78-8097-6517-1-B TABLE OF CONTENTS Introduction... 2 Installing or Replacing the Batteries... 2 Initial Receiver Configuration...
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external
1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and
CABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
SingleNet Single Cable Control System
Single Cable Control System Economical, Reliable and Expandable Two-Wire Single Cable System DRIP/MICRO IRRIGATION PRODUCTS Single Cable Control System System Manager or Irrigation Controller Controls
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
i410/i1010 AC/DC Current Clamp
/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating
1 POLE - 8A Medium Load Control
POWER RELAY 1 POLE - 8A Medium Load Control JS Series FEATURES UL class B (130 C) coil wire insulation 1 form A (SPST-NO) or 1 form C (SPDT) contact Low profile and space saving - Height: 12.5 mm - Mounting
USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)
USER MANUAL MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) An ISO-9001 Certified Company Part #07M460-E Doc. #019021UE Revised 02/23/00 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)
QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000
QUICK INSTALLATION 8-Port Telephony Gateway Model: SPA8000 Table of Contents Connect................................................. 4 Regulatory Information....................................12 WEEE
RLH 2 Wire Digital Phone Fiber Link Card System
RLH Industries, Inc. The leader in rugged fiber optic technology. USER GUIDE! Unconditional Lifetime Warranty U-008 2014C-0924 RLH 2 Wire Digital Phone Fiber Link Card System CARD INSTALLATION INFORMATION
Application Note. PCIEC-85 PCI Express Jumper. High Speed Designs in PCI Express Applications Generation 3-8.0 GT/s
PCIEC-85 PCI Express Jumper High Speed Designs in PCI Express Applications Generation 3-8.0 GT/s Copyrights and Trademarks Copyright 2015, Inc. COPYRIGHTS, TRADEMARKS, and PATENTS Final Inch is a trademark
NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module
DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES
POWER RELAY POLE - 6A / Inrush 20A relay FTR-K-KS Series FTR-K SERIES FEATURES pole 6A, form A or form C Peak inrush current 20A / TV-8 Coil power 400mW High insulation in small package (between coil and
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
HARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
No Phone Line II-48 System
Used in conjunction with an EntraGuard Telephone Entry System, the -48 provides No Phone Line communication and door or gate control through existing building telephone lines without the need to purchase
PC/104, PC/104 -Plus, VarPol connectors
164 PC/104, PC/104 -Plus, VarPol connectors Definitions 166 Technical specifications 168 Hole specifications 169 PC/104 170 PC/104-Plus 172 Accessories: PC/104 and PC/104-Plus 174 VarPol angled pin header
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
Connectors for PCMCIA ExpressCard Technology
DESCRIPTION PCMCIA ExpressCard technology is the next generation for the PC Card standard. The 26 pin host and module connectors offer a smaller form factor than existing PC Card technology. The same connectors
6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES
FTR-K1 SERIES POWER RELAY 1 POLE - 5A/10A Medium Load Control JV Series FEATURES UL, CSA, VDE, SEMKO, CQC recognized UL class B (130 C) wire class Low profile and space saving - Height: 12.5 mm - Mounting
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
SECTION 611 ACCEPTANCE PROCEDURES FOR TRAFFIC CONTROL SIGNALS AND DEVICES
SECTION 611 ACCEPTANCE PROCEDURES FOR TRAFFIC CONTROL SIGNALS AND DEVICES 611-1 Description. This Section sets forth Contract acceptance procedures for installations of traffic control signals and devices
TISP4600F3, TISP4700F3 OBSOLETE
*RoHS COMPLIANT TISP4600F3, TISP4700F3 HIGH OLTAGE BIDIRECTIONAL THYRISTOR OEROLTAGE PROTECTORS TISP4600F3, TISP4700F3 Ion-Implanted Breakdown Region Precise and Stable oltage Low oltage Overshoot under
1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting
Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8
Product Data Sheet 3M Mini-Clamp II Plug and Socket Wiremount Connectors
PD-0050 Product Data Sheet 3M Mini-Clamp II Plug and Socket Wiremount Connectors Page: 1 of 10 Table of Contents 1.0 SCOPE...2 2.0 PRODUCTS TESTED...2 2.1 Cables Tested...3 3.0 GENERAL CONDITIONS...4 3.1
Discontinued. Volition. Fiber Optic Cable. 3Innovation
Volition Fiber Optic Cable Tough enough to take it. Easy to handle. The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm and 50/125 µm multimode fiber, and 9/125