DYNAMIC LIGHT SCATTERING COMMON TERMS DEFINED



Similar documents
ZETA POTENTIAL ANALYSIS OF NANOPARTICLES

Micellar structures and Whisky

Dynamic Light Scattering (aka QLS, PCS)

7. DYNAMIC LIGHT SCATTERING 7.1 First order temporal autocorrelation function.

Setting Size Specifications

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Method Development and Validation for Particle Size and Shape Measurements

High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering

Bruce B. Weiner, Walther W. Tscharnuter, David Fairhurst Brookhaven Instruments Corporation Holtsville, NY US

A GUIDEBOOK TO PARTICLE SIZE ANALYSIS

Diffusion and Fluid Flow

PARTICLE SIZE. By: Philo Morse, MS, and Andrew Loxley, PhD. INTRODUCTION are not as stringent as for scattering techniques.

AP Physics 1 and 2 Lab Investigations

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Supporting Information

Lecture 24 - Surface tension, viscous flow, thermodynamics

Fiber Optics: Fiber Basics

Collagen I Self-Assembly: Revealing the Developing Structures that Generate Turbidity. Supporting Material

Particle motion, particle size, and aerodynamic diameter

2 Absorbing Solar Energy

The accurate calibration of all detectors is crucial for the subsequent data

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))

Application Note: Absorbance

BASIC PRINCIPLES OF PARTICLE

GRADES 7, 8, AND 9 BIG IDEAS

2. Simple Linear Regression

Two-photon FCS Tutorial. Berland Lab Department of Physics Emory University

Solving Simultaneous Equations and Matrices

Section A. Index. Section A. Planning, Budgeting and Forecasting Section A.2 Forecasting techniques Page 1 of 11. EduPristine CMA - Part I

Malvern. Material characterization systems for increased productivity through improved product quality and process control. solutions.

Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives

1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number

Refractive Index Measurement Principle

Experiment #5: Qualitative Absorption Spectroscopy

Molysulfide. Particle Size Analysis

Uses of Derivative Spectroscopy

Dynamics in nanoworlds

AS COMPETITION PAPER 2008

Lecture 1: Basic Concepts on Absorption and Fluorescence

VALIDATION OF WET AND DRY LASER DIFFRACTION PARTICLE CHARACTERISATION METHODS.

Algebra 1 Course Title

X X X a) perfect linear correlation b) no correlation c) positive correlation (r = 1) (r = 0) (0 < r < 1)

(1) The size of a gas particle is negligible as compared to the volume of the container in which the gas is placed.

Infrared Spectroscopy: Theory

Dimensional analysis is a method for reducing the number and complexity of experimental variables that affect a given physical phenomena.

Molecular Spectroscopy

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Chemical Structure of the polymer showing end groups: CH 3 CH 2 CH H

Pre-Algebra Academic Content Standards Grade Eight Ohio. Number, Number Sense and Operations Standard. Number and Number Systems

CHAPTER 13 SIMPLE LINEAR REGRESSION. Opening Example. Simple Regression. Linear Regression

Diffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi

) and mass of each particle is m. We make an extremely small

Chemical Synthesis. Overview. Chemical Synthesis of Nanocrystals. Self-Assembly of Nanocrystals. Example: Cu 146 Se 73 (PPh 3 ) 30

Common Core Unit Summary Grades 6 to 8

IN-LINE PARTICLE SIZE MEASUREMENTS FOR CEMENT AND OTHER ABRASIVE PROCESS ENVIRONMENTS

Acoustics: the study of sound waves

Signal, Noise, and Detection Limits in Mass Spectrometry

ALGORITHM TO DETERMINE THE CALIBRATION PARAMETERS FOR A NDA METHOD OF INVENTORY VERIFICATION IN A DIFFUSION ENRICHMENT CASCADE

Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x

Particle Surface Area

Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces

Algebra Academic Content Standards Grade Eight and Grade Nine Ohio. Grade Eight. Number, Number Sense and Operations Standard

Sample Analysis Design Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors:

Real-time PCR: Understanding C t

SIZE OF A MOLECULE FROM A VISCOSITY MEASUREMENT

Molar Mass of Polyvinyl Alcohol by Viscosity

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

Tips & Tricks GPC/SEC: Analysis and Calibration For Low Molar Mass Macromolecules

Signal to Noise Instrumental Excel Assignment

Florida Department of Education/Office of Assessment January Grade 6 FCAT 2.0 Mathematics Achievement Level Descriptions

NRZ Bandwidth - HF Cutoff vs. SNR

Theory at a Glance (For IES, GATE, PSU)

MATH 095, College Prep Mathematics: Unit Coverage Pre-algebra topics (arithmetic skills) offered through BSE (Basic Skills Education)

Functional Data Analysis of MALDI TOF Protein Spectra

Experiment #1, Analyze Data using Excel, Calculator and Graphs.

Analytical Test Method Validation Report Template

- particle with kinetic energy E strikes a barrier with height U 0 > E and width L. - classically the particle cannot overcome the barrier

Particle size. Integrated systems for particle sizing. detailed specification sheets from

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Validation and Calibration. Definitions and Terminology

Antennas & Propagation. CS 6710 Spring 2010 Rajmohan Rajaraman

Prentice Hall Algebra Correlated to: Colorado P-12 Academic Standards for High School Mathematics, Adopted 12/2009

TCOM 370 NOTES 99-4 BANDWIDTH, FREQUENCY RESPONSE, AND CAPACITY OF COMMUNICATION LINKS

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

DESCRIPTIVE STATISTICS. The purpose of statistics is to condense raw data to make it easier to answer specific questions; test hypotheses.

Modern Construction Materials Prof. Ravindra Gettu Department of Civil Engineering Indian Institute of Technology, Madras

Raman Scattering Theory David W. Hahn Department of Mechanical and Aerospace Engineering University of Florida

The Effect of Temperature on Conductivity Measurement

DO PHYSICS ONLINE FROM QUANTA TO QUARKS QUANTUM (WAVE) MECHANICS

Overview. What is EMR? Electromagnetic Radiation (EMR) LA502 Special Studies Remote Sensing

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

Particle size and stability analysis in turbid suspensions and emulsions with Photon Cross Correlation Spectroscopy, PCCS NANOPHOX

Jorge E. Fernández Laboratory of Montecuccolino (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli, 16, Bologna, Italy

Particle Size Analysis

Transport and collective dynamics in suspensions of swimming microorganisms

business statistics using Excel OXFORD UNIVERSITY PRESS Glyn Davis & Branko Pecar

ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS

Laurence Lurio Department of Physics Northern Illinois University

Copyright 2011 Casa Software Ltd.

Transcription:

DYNAMIC LIGHT SCATTERING COMMON TERMS DEFINED Abstract: There are a number of sources of information that give a mathematical description of the terms used in light scattering. However, these will not usually give assistance in understanding their use in the practical application of the technique. (Ref, 1,2,3,4,5,6) The following list of terms gives a descriptive definition, with notes on their specific use in the context of Dynamic Light Scattering. Malvern Instruments Worldwide Sales and service centres in over 65 countries www.malvern.com/contact 2011 Malvern Instruments Limited

Z-Average size The Z-Average size or Z-Average mean used in dynamic light scattering is a parameter also known as the cumulants mean. It is the primary and most stable parameter produced by the technique. The Z-Average mean is the best value to report when used in a quality control setting as it is defined in ISO 13321 and more recently ISO 22412 which defines this mean as the harmonic intensity averaged particle diameter. The Z-average size will only be comparable with the size measured by other techniques if the sample is monomodal (i.e. only one peak), spherical or near-spherical in shape, monodisperse (i.e. very narrow width of distribution), and the sample is prepared in a suitable dispersant, as the Z-Average mean size can be sensitive to even small changes in the sample, e.g. the presence of a small proportion of aggregates. It should be noted that the Z-average is a hydrodynamic parameter and is therefore only applicable to particles in a dispersion or molecules in solution. Cumulants analysis This is a simple method of analysing the autocorrelation function generated by a DLS experiment. The calculation is defined in ISO 13321 and ISO 22412. As it is a moments expansion it can produce a number of values, however only the first two terms are used in practice, a mean value for the size (Z-Average), and a width parameter known as the Polydispersity Index (PdI). The Z-Average is an Intensity-based calculated value and should never be confused with or directly compared to a Mass or Number mean value produced by other methods. The calculation is defined in the ISO standards, so all systems that use this calculation as recommended should give comparable results if the same scattering angle is used. Polydispersity Index This index is a number calculated from a simple 2 parameter fit to the correlation data (the cumulants analysis). The Polydispersity Index is dimensionless and scaled such that values smaller than 0.05 are rarely seen other than with highly monodisperse standards. Values greater than 0.7 indicate that the sample has a very broad size distribution and is probably not suitable for the dynamic light scattering (DLS) technique. The various size distribution algorithms work with data that falls between these two extremes. The calculations for these parameters are defined in the ISO standard document 13321:1996 E and ISO 22412:2008. 2 Dynamic Light Scattering Polydispersity In light scattering, the term polydispersity and % polydispersity are derived from the Polydispersity Index, a parameter calculated from a Cumulants analysis of the DLS-measured intensity autocorrelation function. In the Cumulants analysis, a single particle size mode is assumed and a single exponential fit is applied to the autocorrelation function and the polydispersity describes the width of the assumed Gaussian distribution. In terms of a protein analysis, a % polydispersity less than 20% indicates that the sample is monodisperse.

Diffusion Coefficient Particles and molecules in suspension/solution undergo Brownian motion. This is the motion induced by the bombardment by solvent molecules that themselves are moving due to their thermal energy. If the particles or molecules are illuminated with a laser, the intensity of the scattered light fluctuates at a rate that is dependent upon the size of the particles as smaller particles are kicked further by the solvent molecules and move more rapidly. Analysis of these intensity fluctuations yields the velocity of the Brownian motion and hence the particle size using the Stokes-Einstein relationship. The diffusion coefficient, therefore, defines this Brownian motion of the analyte or particle in that particular solvent environment. The translational diffusion coefficient will depend not only on the size of the particle core but also on any surface structure, as well as the concentration and type of ions in the medium. Hydrodynamic diameter The hydrodynamic size measured by Dynamic Light Scattering (DLS) is defined as the size of a hypothetical hard sphere that diffuses in the same fashion as that of the particle being measured. In practice though, particles or macromolecules in solution are non-spherical, dynamic (tumbling), and solvated. Because of this, the diameter calculated from the diffusional properties of the particle will be indicative of the apparent size of the dynamic hydrated/solvated particle. Hence the terminology, Hydrodynamic diameter. The hydrodynamic diameter, or Stokes diameter, therefore is that of a sphere that has the same translational diffusion coefficient as the particle being measured, assuming a hydration layer surrounding the particle or molecule. Correlation Curve or correlation function The measured data in a dynamic light scattering (DLS) experiment is the correlation curve which should be a smooth, single exponential decay function for a mono-size particle dispersion. Embodied within the correlation curve is all of the information regarding the diffusion of particles within the sample being measured. By fitting the correlation curve to an exponential function, the diffusion coefficient (D) can be calculated (D is proportional to the lifetime of the exponential decay). With the diffusion coefficient (D) now known, the hydrodynamic diameter can be calculated by using a variation of the Stokes-Einstein equation. For a polydisperse sample this curve is a sum of exponential decays. Y-Intercept or Intercept In DLS the Y-Intercept, or more simply Intercept, refers to the intersection of the correlation curve on the y-axis of the correlogram. The y-intercept can be used to evaluate the signal-to-noise ratio from a measured sample and thus is often used to judge data quality. It is usually scaled such that an ideal signal will give a value of 1, and a good system will give intercepts in excess of 0.6, and greater than 0.9 for the best systems. 3 Dynamic Light Scattering

Deconvolution or Deconvolution algorithm An algorithm-based approach to resolving a mixture of exponentials derived from a polydisperse sample into a number of intensity values each associated with a discrete size band. The particle size distribution from dynamic light scattering (DLS) is derived from a deconvolution of the measured intensity autocorrelation function of the sample. Generally, this is accomplished using a non-negatively constrained least squares (NNLS) fitting algorithm, a common examples being CONTIN. Count Rate or Photon Count Rate In DLS this is simply the number of photons detected and is usually stated in a per second basis. This is useful for determining the sample quality, by monitoring its stability as a function of time, and is also used to set instrument parameters such as the attenuator setting and sometimes analysis duration. The count rate needs to be above some minimum value in order to have enough signal for analysis, however all detectors have a maximum count rate where the response remains linear, and if the count rate is not adjusted automatically, the manufacturer recommendations for adjusting the count rate must be observed. Intensity Distribution The first order result from a DLS experiment is an intensity distribution of particle sizes. The intensity distribution is naturally weighted according to the scattering intensity of each particle fraction or family. For biological materials or polymers the particle scattering intensity is proportional to the square of the molecular weight. As such, the intensity distribution can be somewhat misleading, in that a small amount of aggregation/ agglomeration or presence or a larger particle species can dominate the distribution. However this distribution can be used as a sensitive detector for the presence of large material in the sample. Volume Distribution Although the fundamental size distribution generated by DLS is an intensity distribution, this can be converted, using Mie theory, to a volume distribution or a distribution describing the relative proportion of multiple components in the sample based on their mass or volume rather than based on their scattering (Intensity.) When transforming an intensity distribution to a volume/mass distribution, there are 4 assumptions that must be accepted. All particles are spherical All particles are homogeneous The optical properties of the particles are known, i.e. the real & imaginary components of the refractive index 4 Dynamic Light Scattering There is no error in the intensity distribution

An understanding of these assumptions is particularly important since the DLS technique itself produces distributions with inherent peak broadening, so there will always be some error in the representation of the intensity distribution. As such, volume and number distributions derived from these intensity distribution are best used for comparative purposes, or for estimating the relative proportions where there are multiple modes, or peaks, and should never be considered absolute. It is therefore good practice to report the size of the peak based on an intensity analysis and report the relative percentages only (not size) from a Volume distribution analysis. References: [1] International Standard ISO13321 Methods for Determination of Particle Size Distribution Part 8: Photon Correlation Spectroscopy, International Organisation for Standardisation (ISO) 1996. [2] ] International Standard ISO22412 Particle Size Analysis Dynamic Light Scattering, International Organisation for Standardisation (ISO) 2008. [3] Dahneke, B.E. (ed) Measurement of Suspended Particles by Quasielastic Light Scattering, Wiley, 1983. [4] Pecora, R. Dynamic Light Scattering: Applications of Photon Correlation Spectroscopy, Plenum Press, 1985. [5] Washington, C. Particle Size Analysis In Pharmaceutics And Other Industries: Theory And Practice, Ellis Horwood, England, 1992. [6] Johnson, C.S. Jr. and Gabriel, D.A. Laser Light Scattering, Dover Publications, Inc., New York 1981 5 Dynamic Light Scattering

Malvern Instruments Limited Grovewood Road, Malvern, Worcestershire, UK. WR14 1XZ Telephone: +44 (0)1684 892456 Facsimile: +44 (0)1684 892789 Malvern Instruments is part of Spectris plc, the Precision Instrumentation and Controls Company. Spectris and the Spectris logo are Trade Marks of Spectris plc. All information supplied within is correct at time of publication. Malvern Instruments pursues a policy of continual improvement due to technical development. We therefore reserve the right to deviate from information, descriptions, and specifications in this publication without notice. Malvern Instruments shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Malvern and the hills logo, Bohlin, Gemini, Insitec, ISys, Kinexus, Mastersizer, Morphologi, Rosand, SyNIRgi, Viscotek and Zetasizer, are International Trade Marks owned by Malvern Instruments Ltd. Malvern Instruments Worldwide Sales and service centres in over 65 countries www.malvern.com/contact 2011 Malvern Instruments Limited MRK1764-01