Residual devices Residual devices Description The devices offer a wide range of product for all of your fault protection needs. & C large offering for standard instantaneous and selective C and types. ll sizes up to 63 m with sensitivity thresholds up to 1 are offered in all possible pole configurations. BB RCDs carry many marks and approvals for the worldwide market. Features RCDs assure protection to equipment against leakage to earth. UL 1053 UL file number: E06 F00C F00 Type C mperage (),5,0,63,80,,15 1,5,0,63,80,,15 1 Voltage Up to 80 VC Up to 80 VC Sensitivity (m) 0.01, 0.03, 0.1, 0.3, 0.5 0.01, 0.03, 0.1, 0.3, 0.5 F00 P-R Type mperage () 5,0,63,80,,15 1 Voltage Up to 80 VC Sensitivity (m) 0.03 F00C S F00 S Type C mperage () 0,63 0,63,,15 1 Voltage Up to 80 VC Up to 80 VC Sensitivity (m) 0.1, 0.3, 0.5, 1.0 0.1, 0.3, 0.5, 1.0 1 15 versions are not UL approved.
F00C C Type F0C F0C m 10 F0C-/0.01 Type C Suitable for protection against C earth leakage & -15 range Can be used as a main device providing ground fault protection against earth leakage for several MCB branch devices 5 F0C-5/0.03 0 F0C-0/0.03 63 F0C-63/0.03 80 F0C-80/0.03 F0C-/0.03 5 F0C-5/0.1 0 F0C-0/0.1 63 F0C-63/0.1 80 F0C-80/0.1 F0C-/0.1 5 F0C-5/0.3 0 F0C-0/0.3 63 F0C-63/0.3 80 F0C-80/0.3 F0C-/0.3 5 F0C-5/0.5 0 F0C-0/0.5 63 F0C-63/0.5 80 F0C-80/0.5 F0C-/0.5 m 5 F0C-5/0.03 0 F0C-0/0.03 63 F0C-63/0.03 80 F0C-80/0.03 F0C-/0.03 15 F0C-15/0.03 1 5 F0C-5/0.1 0 F0C-0/0.1 63 F0C-63/0.1 80 F0C-80/0.1 F0C-/0.1 15 F0C-15/0.1 1 5 F0C-5/0.3 0 F0C-0/0.3 63 F0C-63/0.3 80 F0C-80/0.3 F0C-/0.3 15 F0C-15/0.3 1 5 F0C-5/0.5 0 F0C-0/0.5 63 F0C-63/0.5 80 F0C-80/0.5 F0C-/0.5 15 F0C-15/0.5 1 See page.36 F0C F0C 1 15 versions are not UL approved.
/ F00C S C Type F0C S m 0 0 F0CS-0/0.1 63 F0CS-63/0.1 0 F0CS-0/0.3 63 F0CS-63/0.3 0 F0CS-0/0.5 63 F0CS-63/0.5 0 F0CS-0/1.0 63 F0CS-63/1.0 m 0 0 F0CS-0/0.1 63 F0CS-63/0.1 0 F0CS-0/0.3 63 F0CS-63/0.3 0 F0CS-0/0.5 63 F0CS-63/0.5 0 F0CS-0/1.0 63 F0CS-63/1.0 F0C S Type C S (Selectivity) Intentional tripping delay, permitting selectivity with downstream instantaneous devices 5k surge resistance Suitable for protection against C earth leakage & 0 and 63 range Can be used as a main device providing ground fault protection against earth leakage for several MCB branch devices See page.36 F0C S F0C S 1/ 3/ 5/6 In=50-63 Y1 Y 1/ 3/ 1/ 3/
F00 Type F0 F0 m 10 F0-/0.01 5 F0-5/0.03 0 F0-0/0.03 63 F0-63/0.03 80 F0-80/0.03 F0-/0.03 5 F0-5/0.1 0 F0-0/0.1 63 F0-63/0.1 80 F0-80/0.1 F0-/0.1 5 F0-5/0.3 0 F0-0/0.3 63 F0-63/0.3 80 F0-80/0.3 F0-/0.3 5 F0-5/0.5 0 F0-0/0.5 63 F0-63/0.5 80 F0-80/0.5 F0-/0.5 Type Suitable for protection against C and pulsating DC earth leakage & -15 range Can be used as a main device providing ground fault protection against earth leakage for several MCB branch devices m 5 F0-5/0.03 0 F0-0/0.03 63 F0-63/0.03 80 F0-80/0.03 F0-/0.03 15 F0-15/0.03 1 5 F0-5/0.1 0 F0-0/0.1 63 F0-63/0.1 80 F0-80/0.1 F0-/0.1 15 F0-15/0.1 1 5 F0-5/0.3 0 F0-0/0.3 63 F0-63/0.3 80 F0-80/0.3 F0-/0.3 15 F0-15/0.3 1 5 F0-5/0.5 0 F0-0/0.5 63 F0-63/0.5 80 F0-80/0.5 F0-/0.5 15 F0-15/0.5 1 See page.36 F0 F0 1 15 versions are not UL approved.
F00 P-R Type F0 P-R F0 P-R m Type P-R (High Immunity) Resistance to unwanted tripping (high immunity) 3k surge resistance Suitable for protection against C and pulsating DC earth leakage & 5-15 range Can be used as a main device providing ground fault protection against earth leakage for several MCB branch devices See page.36 5 F0-5/0.03PR 0 F0-0/0.03PR 63 F0-63/0.03PR 80 F0-80/0.03PR F0-/0.03PR m F0 P-R 5 F0-5/0.03PR 0 F0-0/0.03PR 63 F0-63/0.03PR 80 F0-80/0.03PR F0-/0.03PR 15 F0-15/0.03PR 1 F0 P-R 1/ 3/ 5/6 In=50-63 Y1 Y 1 15 versions are not UL approved. 1/ 3/ Phone: 800.89.01 - Fax: 888.73.773 - Web: www.clrwtr.com 1/ 3/ - Email: info@clrwtr.com
F00 S Type F0 S F0 S m 0 Type S (Selectivity) Intentional tripping delay, permitting selectivity with downstream instantaneous devices 5k surge resistance Suitable for protection against C and pulsating DC earth leakage & 0-15 range Can be used as a main device providing ground fault protection against earth leakage for several MCB branch devices See page.36 0 F0S-0/0.1 63 F0S-63/0.1 F0S-/0.1 0 F0S-0/0.3 63 F0S-63/0.3 F0S-/0.3 0 F0S-0/0.5 63 F0S-63/0.5 F0S-/0.5 0 F0S-0/1.0 63 F0S-63/1.0 F0S-/1.0 m 0 0 F0S-0/0.1 63 F0S-63/0.1 F0S-/0.1 0 F0S-0/0.3 63 F0S-63/0.3 F0S-/0.3 15 F0S-15/0.3 1 0 F0S-0/0.5 63 F0S-63/0.5 F0S-/0.5 15 F0S-15/0.5 1 0 F0S-0/1.0 63 F0S-63/1.0 F0S-/1.0 F0 S F0 S 1/ 3/ 5/6 1 15 versions are not UL approved. In=50-63 Y1 Y
Functions and classification criteria RCDs Power loss of RCDs RCCBs F00 series Current in [] Power loss [W] P P 1.5-5.0.8 0.8 8. 63 7. 13. Performance in altitude of RCDs Up to the height of 000 m, BB RCDs do not undergo any alterations in their rated performances. Over this height the properties of the atmosphere change in terms of composition, dielectric capacity, cooling capacity and pressure, therefore the performances of the RCDs undergo derating, which can basically be measured in terms of variations in significant parameters, such as the maximum operating voltage and the rated. F00 ltitude [m] 000 0 000 service voltage Ue [V] 00 380 380 in In 0.96xln 0.93xln