Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements



Similar documents
Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters

Data Communications Competence Center

GigaSPEED X10D Solution How

Impedance 50 (75 connectors via adapters)

Experiment 7: Familiarization with the Network Analyzer

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows

Solving Difficult Cable Measurements

Cable Analysis and Fault Detection using the Bode 100

Agilent Test Solutions for Multiport and Balanced Devices

White Paper: What Component Compliance Means for CAT6A System Performance

New Technology Developments and How They Impact Your Structured Wiring Choices

Annex 113A Description of cable clamp and test setup. (informative) 113A.1 Overview

2. The Vector Network Analyzer

Network Design. Yiannos Mylonas

Coupling attenuation up to 2 GHz with virtual Balun

Crosstalk effects of shielded twisted pairs

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

S-PARAMETER MEASUREMENTS OF MEMS SWITCHES

Balun Parameter Definitions & Measurement May 2004

The Application of Vector Network Analyzers in Balanced Transmission Line Signal Integrity Measurements

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

RF Network Analyzer Basics

with Component Rating A Simple Perspective

Applying Error Correction to Network Analyzer Measurements. Application Note Table of Contents. Page

Nexus Technology Review -- Exhibit A

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR

Agilent Measuring Noninsertable Devices

10 Gigabit Ethernet over copper: Unshielded, unprotected?

Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance

R3765/67 CG Network Analyzer

a 1 a 2 2 Port b 2 b 1 Multi-Port Handset Switch S-Parameters Application Note AN20 Seven-Port S-Parameter Definition Introduction Summary:

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian

Model CFA-24 Transparent Cable Farm Automation Switch

Networks. The two main network types are: Peer networks

Agilent 8720 Family Microwave Vector Network Analyzers

Calibration Procedure for Measuring S-Parameters in Balun Applications on 150-Ω High-Speed Cables

Current Probes. User Manual

Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

Michael Hiebel. Fundamentals of Vector Network Analysis

Application Note Noise Frequently Asked Questions

Chapter 4 Connecting to the Internet through an ISP

How to Choose the Right Cable Category

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

Utilizing Time Domain (TDR) Test Methods For Maximizing Microwave Board Performance

Agilent 8753ET/8753ES Network Analyzers

SHEET 5 CABLE TELEVISION SYSTEM

Measurements in 75 Ω Coaxial Transmission Lines

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Broadband Push-Pull Power Amplifier Design at Microwave Frequencies

Cable Sharing in Commercial Building Environments

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek

75 Ω Transmission System

IT Cabling Solutions

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

ELECTRICAL CHARACTERISATION OF SEMI-RIGID COAXIAL CABLES WITH SMA AND K CONNECTORS. Carmen Diez Rafael García Juan Daniel Gallego.

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE GCU Singapore, 2011/03 V1.

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

SECTION TELECOMMUNICATIONS ACCEPTANCE TESTING

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

USB 3.0 INTERNAL CONNECTOR AND CABLE SPECIFICATION

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

MYTHBUSTING Takes on Shielded Cabling

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Communication, Signal & Data Cables

Balanced vs. Unbalanced Audio Interconnections

High Speed Characterization Report

The N2PK Vector Network Analyzer (N2PK VNA) Original by Paul Kiciak, N2PK, 2007 * (*Pages edited or added by VE7WRS, 2009)

Current Probes, More Useful Than You Think

Design of Bidirectional Coupling Circuit for Broadband Power-Line Communications

HIGH RELIABILITY POWER SUPPLY TESTING

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Network Engineers Everywhere:

APPLICATION NOTES POWER DIVIDERS. Things to consider

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

24 GHz Point-to-Point 1.4+ Gbps Radio. Datasheet. Model: AF24. High Performance Wireless Backhaul. Long Range of 13+ km

Abstract: This document examines the alien NEXT performance of various bundled cables and measures the impact upon various networks performance.

AMP CO Plus Insert for Cat. 6 A Applications

spinner Measurement & Calibration equipment for network analyzers

1000BASE-T1: 3-Port Conversion/Balance Measurement for Cables and Components

iva Cable & Antenna Analyzer

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

Implementing Fast Ethernet

February 2010 Number Vector Network Analyzer upgrade to SureCAL Power Sensor and RF Components Packages

HP 8970B Option 020. Service Manual Supplement

Transcription:

Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements Stefan Estevanovich Rafael Herrera, Nadim Kafati Hitachi Cable USA NDC Technologies/DCM Cable Test Solutions Manchester, New Hampshire Hayward, California 800-772-0116, 510-670-7210, rafael.herrera@betalasermike.com stefan.estevanovich.sn@hca.hitachi-cable.com 510-670-7202, nadim.kafati@betalasermike.com Abstract Standards organizations are progressing in the development of test requirements and specification limits for Category 8 cabling components for frequencies up to 2 GHz. Previous to Category 8 cabling specifications, the transmission measurement test procedures were based on 2-port Vector Network Analyzers (VNAs) and conventional balun (balancedunbalanced) transformers. These baluns were used to interface the unbalanced ports of the VNA to the differential device under test. Conventional balun transformers use flux linkages to transmit the energy from the input circuit to the output circuit. Conventional baluns with a 1 MHz lower frequency tend to be limited at frequencies above 1 GHz. In one method to overcome this balun limitation, 4-port VNAs are used to perform Category 8 testing to 2 GHz. On this 4-port technique, the VNA measures full 4-port, single-ended S- parameters by considering the device under test a 4-port device. Test data acquired with the 4-port method will be compared against data acquired using a balun-based system capable of extending to at least 2 GHz the test frequency. The scope of this paper is to: - Compare and analyze Category 8 cable transmission data obtained from a 4-port VNA with data obtained from a 2-port VNA system with baluns. Advantages and disadvantages of the two testing methods will be reviewed. - Show an implementation of IEC/TR 61156-1-5 (Return Loss correction procedures) on the Return Loss data obtained with the TLT baluns. Keywords: Category 8, balun, VNA, TLT, Insertion Loss, Return Loss, Near End crosstalk, Far End Crosstalk, IFFT, LAN, Modal Decomposition. Mathematical Balun 1. Introduction 40GBase-T will transport data at a rate of 40 Gp/s over 4-pair Category 8 cabling. The test frequency for Category 8 cabling components is 2 GHz. This frequency is 4 times higher than the 500 MHz test frequency of Category 6A cabling components. Testing to 2 GHz brings challenges not encountered in testing at lower frequencies. Cable preparation, cable connecting fixtures to interface the system to the vector network analyzer, s-parameters calibration standards are some of these challenges. Previous to Category 8 baluns were the main component used to interface the balanced twisted pairs to the unbalance output ports of the VNAs. Testing with baluns has been extensively described in the twisted pair testing documentation. With the test frequency increase to 2 GHz another approach for testing twisted pairs becomes very relevant. This other testing approach is based on the unbalanced data of the individual conductors measured with a 4-port VNA. Each end of the 2 conductors of the pair is connected to a VNA port. All other conductors of the 4-pair cable under test must be properly terminated. In the following sections we will provide a detailed description of these two test methods. We will also test a 4-pair Category 8 cable using both methods and present the test results. 2. Balun measurements Baluns are used to interface the unbalance ports of the VNA to the balanced twisted pairs. In addition to providing balance to unbalance interface baluns also provide impedance transformation. Therefore these baluns provide the interface between the VNA s 50 Ω unbalanced port to the 100 Ω impedance of the balanced twisted pair. There are two types of baluns: conventional winding based baluns and transmission line based transformer baluns or TLT. With conventional windings balun transformer is not possible to get the 1 MHz to 2 GHz bandwidth required to test Category 8 cables. Therefore TLT baluns are used to test Category 8 cables in the bandwidth required. The TLT used are made of coaxial transmission lines of known impedance configured to provide the 50 Ω to 100 Ω impedance matching. Fine-tuned and optimized TLT baluns operating to 2.2 GHz were used for the tests on this paper. NDC technologies DCM cable testing products ES-2G automatic switch was used to automate the insertion loss, return loss, near end crosstalk and far end crosstalk testing of the Category 8 cables tested. The ES-2G switch was connected to a 2-port E 5071B VNA. The ES-2G switch is specified from 1 MHz to 2.2 GHz. The noise floor level for crosstalk testing is better than 90 db at 2.2 GHz. The ES-2G switch is capable of performing return loss measurement of up to 35 db in the 1 MHz to 2.2 GHz frequency range. Figures 1 and 2 show the balun measurement configurations. All pairs not under test are terminated in differential and common mode. Traditional SOLT s-parameter calibration is used for the balun measurements at the cable connecting point. 788

Figure 1 - IL Test Configuration Figure 4 ES- 2G Automatic Switching System 4. Single Wire Test Configuration (4-port) Figure 2 - RL Test Configuration 3. 4-Pair Automatic Switch Figure 3 4 Pair Automatic Switch On this test configuration each test position uses an independent balun. Each VNA port is switched to all pairs under test by means of multiple pole RF coaxial switches. Each measurement path is calibrated using differential SOLT calibration at the cable connection point. A full 2-port calibration model in the error correction algorithm. All differential calibration standards are verified to 2.2 GHz using an NIST traceable VNA. Figure 5 Insertion Loss Test Configuration (TIA) A 4-port network analyzer is required to perform the single wire testing. The connection between the network analyzed and the pair under test is done through two separate coaxial paths with a 50 Ohm impedance. Each wire of the pairs not under test is terminated with 50 Ohm coaxial load. The network analyzer performs all the single wire measurements and all calculations required to provide the results in a differential format. 5. Cable Measurements Measurement Set Up In both cases the measurement set up was as follows: frequency range: 1 MHz to 2000 MHz Number of points: 1601 IF Bandwidth: 300 Hz Frequency sweep: Linear Power Level: 10o db Cable temperature: 23 C Cable Samples U/FTP unjacketed Category 8.2 (30 meters) F/UTP jacketed Category 8.1 (30 meters) 789

Cable Test Results Figure 6 Return Loss Balun vs Single Wire Figure 9 ACR FEXT Balun vs Single Wire Figure 7 Insertion Loss Balun vs Single Wire Figure 10 Return Loss Balun vs Single Wire Figure 8 Exploded IL view showing thru standard effect Figure 11 Insertion Loss Balun vs Single Wire 790

Insertion Loss: Single wire insertion loss measurements and balun based insertion loss measurements show good correlation. Selection of the thru standard is critical to obtain a smoother and wave free insertion loss measurement. The effect of the return loss on insertion loss is more evident on shorter cables Figure 12 Near End Crosstalk Balun vs Single Wire 6. Evaluation of Test Results Sample preparation Direct balun measurement: Followed typical laboratory LAN cables test techniques. Cable connection was performed using a printed circuit board (PCB) assembly attached directly to the TLT balun with SMB connectors. Impedance matched PCB traces connected the IC sockets to the SMB connectors. Automatic balun measurements: Requires spreading of the pairs under test Connection of the pair under test is performed by using terminating cubes that connect directly to 50 Ohm contact path. Shielded cups are used to obtain high isolation between test positions Single wire measurements: A 50 Ohm impedance controlled printed circuit assembly (PCA) with SMA connectors connects directly to the 4-port VNA. IC type sockets were used to connect the pair under test to the PCA. S-parameter calibration Direct balun and automatic balun measurements: Full 2-port differential SOLT were used. Different Thru cables were used to analyze the effect of the transmission calibration on the insertion loss measurements Single wire measurements: A 4-port Ecal was used to perform the s-parameter calibration on the 4-port VNA. Return Loss: The results are comparable in both methods. Cable preparation and handling is very important especially in automatic measurements. This effect is easily removed using DSP techniques Crosstalk: Care must be taken in manual measurements to maintain proper isolation between pairs. Proper termination of unused pairs is critical for accurate results. Proximity to ground of the pairs under test affect the results especially at lower frequencies. 7. Category 8 Alien Crosstalk Test Set Up Figure 13 - ES-2G AXT Head An ES-2G modified test head with 4 isolated measurement positions and 24 terminated positions is used for connecting 7 cables for an six-around-1 alien crosstalk test. To simplify the connecting and disconnecting the pairs under test Wago plugs and receptacles are fitted on all 28 pairs. A utility program guides the user on the different pair connections to obtain the crosstalk results. The test results populate an Excel spreadsheet as the measurements are taken. Once the spread sheet is filled all the power sum required are automatically calculated. Alien crosstalk heads are interchangeable with ISTP and UTP heads. (ANEXT and AFEXT Test results were not available at the time of this paper publication) 791

8. Removal of cable end preparation effects from reflection tests It is well known that the length of jacket removed during LAN cable preparation for testing affects the impedance and return loss test results. As the frequency increases a tail up/down effect is seen on these reflection measurements As the length of jacket removed shortens, the frequency at which the tailing up/down effect is seen increases. However, it will always be necessary to remove some of the cable jacket; therefore there will always be a tailing- up/down effect due to the length of jacket removed. This may be very confusing to the cable manufacturers since they may reject good cable or pass bad cable due to failures on the reflection test results. The reproducibility of the reflection test results is also affected since the end of cable prepared by different individuals provides different reflection test results. IEC Technical report IEC/TR 61156-1-5 describes a process to eliminate this jacket removal effects. The process is based in a conversion of the frequency domain results to time domain were digital signal processing (DSP) techniques are used to remove the jacket effect of the results. Once the effects are removed the data is converted back to the frequency results. The conversion of the data from frequency domain to time domain and back to frequency domain is performed using Inverse Fast Fourier Transformation (IFFT) and the conversion back to frequency domain is performed using Fast Fourier Transformation (FFT). Correction procedure for the measurement results of return loss and input impedance. Test Results Figure 14 Return Loss with DSP and without DSP Figure 15 Tail Down effect removal with DSP 8. Conclusions It is well known that the 4 port technology allows the capability of testing balanced pairs without the frequency range limitations of baluns. However, baluns with TLT technology can offer bandwidths that are capable of covering the range of frequencies of the Category 8 proposals. As the standards for the Category 8 cables continue to progress towards ratification, there is also the need for further advances in the testing requirements and guidelines to meet the needs of those higher frequencies. A significant technical requirement for accurate measurements is fixturing and calibration. And with the comparison testing completed for this paper, it was the calibration and fixturing that caused the some of the most visible effects and differences between the balun and 4 port measurements with this set of tests. E-cal type of calibration offers simplicity and accuracy, but is difficult to implement with a switched system and still requires additional procedures to remove effects of the test fixture. Some more complex E-cal type calibration techniques may require a higher level of network analyzer as well. Short/Open/Load/Through calibration techniques also present challenges of their own. In particular, the calibrated load resistor must be both carefully chosen and characterized, and the quality of connection of the resistor to the fixture plays a measurable role in measurements such as Return Loss. And the through measurement, particularly at these higher frequencies requires care in choosing the design for the through device. Anomalies inherent in test fixtures do affect the test results for all parameters, but most significantly with RL measurements. And it is the effects on RL measurements that are the most difficult to minimize. Another separate effect on RL measurements is the preparation of the cable itself. Whether shielded or unshielded pairs, the small length of exposed conductor at the test fixture does affect the impedance at the test terminals, with the effect tending to be more pronounced with unshielded pairs under an overall shield. The results in this paper demonstrate the ability to remove some or most of the fixture effects with software. The implementation of this DSP technique for the 4-port single wire measurements should be investigated further, and will likely play an important role in test standards as the frequency of testing expands. 792

9. References [1]-Koichi Yanagawa et al, A Measurement of Balanced Transmission Lines Using S-Parameters. IEEE Transactions [2]-ANSI/TIA 568 C.2 [3]-ANSI/TIA 1183-1 (Draft) [4]-Clayton R. Paul Analysis of Multi-conductor Transmission Lines, Wiley [5]- Cross Jon, Koichi Yanagawa, Modal Decomposition Measurement Technique. IWCS 1995 proceedings [6] IEC/TR 61156-1-5 10. BIO Stefan Estevanovich Hitachi Cable America Inc. Stefan.Estevanoivch.sn@hca.hitachi-cable.com Stefan Estevanovich is currently the Quality Engineer for Hitachi Cable America in Manchester, New Hampshire. He is responsible maintaining and developing current test protocols and procedures, for various types of communication cables from copper to fiber optics. Stefan has a AS in Broadband Networking form New Hampshire Technical College, and BS in Electronic Engineering from the University of New Hampshire Rafael E. Herrera NDC Technologies, DCM Products rafael.herrera@betalasermike.com Rafael Herrera is currently Beta LaserMike s Chief Engineer for DCM Products in Hayward, California. He is responsible for Product Design, Product Development, and Technical Support of automatic measuring systems for telephone/dsl, Local Area Network (LAN), and coaxial cables/assemblies. Mr. Herrera has an Electronics Engineering degree from University Xaveriana in Bogotá, Colombia and a Master's of Science degree in Operations Research from California State University, East Bay. Nadim Kafati NDC Technologies, DCM Products nadim.kafati@betalasermike.com Nadim Kafati is currently Beta LaserMike s Senior System Design Engineer for DCM Products, in Hayward, California. Nadim has a BS in Electrical Engineering from Lafayette College in Easton, PA, and a MS in Electrical Engineering from Rensselaer Polytechnic Institute in Troy, NY. 11. Acknowledgments Hitachi Cable USA for providing the Category 8.1 and Category 8.2 cables that were used to collect the data for this paper. In addition to providing the Category 8 cables Hitachi cables also provided: - The 2-port and 4-port VNAs used to collect the test data andthe fixturing and calibration devices for the single wire testing - The laboratory space and technical assistance for performing the cable testing. 793