4 X 1 3/8 X 3/16 CHANNEL 101.6 x 34.9 x 4.8 CHANNEL

Similar documents
Submittal Sheet. Product: Item# Description Unit Pack

RESEARCH REPORT RP04-2 NOVEMBER 2004 REVISION Committee on Specifications for the Design of Cold-Formed Steel Structural Members

Best MATERIALS.com WEATHER GARD TM. Discount Warehouse. Product Guide

VERTICAL LOCK Table of Contents

Owner's Manual & Assembly Instructions

FASTENERS. Self-Drilling Screws Made In USA. Product Line THE. Selecting the Length of the Drill Point. Product Description

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

TEST PROCEDURE FOR FIELD WITHDRAWAL RESISTANCE TESTING

Connection Solutions

How To Make A Power Drill

ABSeam Panel Overview and Installation Instructions

Asphalt Shingle Application Requirements

Residential Roofing Guide

INSTALLATION OF A BAY WINDOW

Fastener Loads for Plywood Screws Number E830D August 2005

Screw Patterns Roof & Walls TR-36 MD-36 TSM-32. PBR-Panel

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

DENVER MODEL 30 X 30 SPECIFICATIONS

CRASH RAIL INSTALLATION HEIGHT

RPS - sales@rpssolar.com San Bruno Cove, San Diego, CA 92130

Submittal Information

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

EJOT Spiralform. The thread formers for metal. EJOT The Quality Connection

PART 1 GENERAL 1.1 SECTION INCLUDES

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

S C R E W S THE ORIGINAL ROBERTSON L ORIGINAL HVAC FASTENER PROGRAM PROGRAMME HVAC

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

PART E SPECIFICATIONS

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

9. Direct screwing into plastics and metal

Standing Seam Roof Systems

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Screw Thread Design. Rev

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

HUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

LP OSB Sheathing & Structural 1 Sheathing

Preformed Metal Roofing and Siding

ATLANTA MODEL SPECIFICATIONS

Machine Screws, Dowel Pins and Hardware

Best Barns USA Assembly Book

HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

AA Solar and Sun Power Plus

BURNISHED SLATE COVER PHOTO: SLATE GREY

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

RIGHT ANGLE CLINCH FASTENERS BULLETIN

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For:

PANELIZED HOME INSTALLATION GUIDELINE

SMALL SCALE ASTM E 119/UL 263 ONE HOUR FIRE TESTING FOR MARINOWARE ON JOIST-RITE WITH ARMOROC FLOOR VTEC # TESTED: MAY 23, 2008 REVISION

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

WT WR. Lateral compression reinforcements EN Data sheet No Convincing advantages:

COLORADO MODEL. 35 x 65 SPECIFICATIONS

Seismic Technical Guide

STANDARD OPEN PATIO COVER

European Technical Approval ETA-12/0500

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

DSM 1 (800)

Step 11 Static Load Testing

CCR274SS. A CRES SOLID FILM LUBE PASSIVATE CCR274CS p e r per per per (MS20604R) AMS 5731 ASTM A-493 MIL-L QQ-P-35 L F

Ceta Form Tool Containers & Assortments

Fastener Handout. Introduction: Engineering Design Representation 2. Threads 2. Local Notes (callouts) 8. Threaded Mechanical Fasteners 13

There is no upside to. down time

SECTION STANDING SEAM METAL ROOF

HUS-HR Stainless steel Concrete Screw A CE conformity. Corrosion resistance. European Technical Approval

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

AZEK Rail Install Guide

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Design of Cold-Formed Steel Shear Walls

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

Section Page Section Page

Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8 smaller than root diamter of fastener.

The Keep It Simple, Steel (KISS) Standard

PRO-PANEL II. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information

Veneer Anchors. Masonry Veneer Anchors. Description. Applications

FLAT ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

SELF-CLINCHING STANDOFFS BULLETIN

Guidelines for Earthquake Bracing of Residential Water Heaters

Installation Instructions and Ordering Information

Premium Nixalite All Stainless Steel Bird Barrier Spikes Includes specifications for: Premium Nixalite Models S, H and W and Mounting Hardware.

Trundle Bed Plans (For Use Under Twin or Full-Size Standard Length Beds)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

lindab duct suspension & support system Duct suspensions & Support systems

DELTA PT. Calculable Extra Performance

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

Installation and Assembly: Desktop Mount with Desk Clamp and Grommet for 19" - 30" LCD Screens

Cable Runways & Accessories


Mounting Tripod Kit Installation Manual

Transcription:

4 X 1 3/8 X 3/16 CHANNEL 101.6 x 34.9 x 4.8 CHANNEL ALLOWABLE UNIFORM LOADS (lbs./ft. / N/m.) Laterally Supported A w = 0.680 in. 2 / 438.7mm 2 Wt. = 0.88 lbs./ft. / 1.31kg/m. I = 2.62 in. 4 / 1090526mm. 4 S = 1.31 in. 3 / 267mm. 3 SPAN FT/m This item is stocked in 20foot lengths in Standard Polyester (ST) and Polyester Fire Retardant (FR). Other lengths available in mill run quantities. The mill run on this item is 1,000 feet. DEFLECTION MAXIMUM LOAD L/100 L/150 L/180 L/240 L/360 3/0.91 435/6343 F v / / / / 296/4322 4/1.22 244/3562 F v / / / 211/3086 1/2053 5/1.52 156/2275 F b / / 153/2237 115/1675 76/1112 6/1.83 108/1576 F b / / 92/1336 68/999 45/662 7/2.13 79/1154 F b / 71/1029 59/855 44/638 29/421 8/2.44 60/881 F b / 48/695 40/577 29/430 19/282 9/2.74 48/693 F b / 34/490 28/406 21/301 13/196 10/3.05 38/559 F b 37/540 24/356 20/295 15/218 10/1 The part weight has been deducted in the above table. English/ Metric Orders for less than mill run quantities will be subject to set up charges as well as premium per foot cost. 264 Reynoldsdale Road, Bedford, PA 155227401 Phone: 86238125 Sales Fax: 86236032 www.bedfordplastics.com Email: frpsales@bedfordplastics.com 47 6/2007

3 1/2 X 1 1/2 X 3/16 CHANNEL 88.9 x 38.1 x 4.8 CHANNEL ALLOWABLE UNIFORM LOADS (lbs./ft. / N/m.) Major Axis ********Laterally Supported ********** A w (in. 2 /mm. 2 )=0.54 / 348.3 Wt.(lbs./kg/m)=0.86 / 1.28 I(in. 4 /mm. 4 )= 1.92 / 799164 S(in. 3 /mm. 3 )= 1.10 / 18026 SPAN MAXIMUM DEFLECTION FT/m LOAD L/100 L/150 L/180 L/240 L/360 3/0.91 298/4353 Fv / / / / 221/3228 4/1.22 167/2442 Fv / / / 157/2286 104/1519 5/1.52 107/1558 Fb / / / 84/1233 56/817 6/1.83 74/1077 Fb / / 67/980 50/731 33/483 7/2.13 54/788 Fb / 52/753 43/625 32/465 21/305 8/2.44 41/600 Fb / 35/506 29/419 21/311 /202 9/2.74 32/471 Fb / 24/355 20/293 15/216 10/139 10/3.05 26/378 Fb / 18/256 /211 11/155 7/98 11/3.35 21/310 Fb 20/292 13/190 11/156 8/113 5/71 12/3.66 18/258 Fb 15/223 10/4 8/117 6/84 4/51 Minor Axis ********Laterally Supported ********** A w (in. 2 / mm. 2 )=0.44 / 283.9 Wt.(lbs./ kg/m)=0.86 / 1.28 I(in. 4 / mm. 4 )=0.22 / 91571 S(in. 3 / mm. 3 )=0.21 / 3441 SPAN MAXIMUM DEFLECTION FT/m LOAD L/100 L/150 L/180 L/240 L/360 3/0.91 154/2245 Fb 115/1683 77/1117 64/928 47/693 31/457 4/1.22 86/1256 Fb 49/716 32/472 27/391 20/290 13/188 5/1.52 55/799 Fb 25/363 16/237 13/195 10/3 6/90 6/1.83 38/550 Fb /205 9/132 7/107 5/77 3/46 The part weight has been deducted in the above tables. English/ Metric This item is stocked in 20foot lengths in Standard Polyester (STD) and Polyester Fire Retardant (FR). Other lengths available in mill run quantities. The mill run on this item is 1,000 feet. Orders for less than mill run quantities will be subject to setup charges as well as premium per foot cost. 264 Reynoldsdale Road, Bedford, PA 155227401 Phone: 86238125 Sales Fax: 86236032 www.bedfordplastics.com Email: frpsales@bedfordplastics.com 45 6/2007

TEKS WOODTOMETAL SELFDRILLING FASTENERS Selector Guide Part Head Drill Drill & Tap Wood Description Box Number Style Point Capacity Attachment Applications Range Qty 1565500 1016 x 1'' Wafer #3.030.175 1/4''1/2'' 2,500 1791000 1016 x 113/16'' **PSD Flat #3.030.175 1/4''3/4'' 2,500 1077000 1024 x 3/4" Wafer #3.036.175 1/4''3/8'' 8,000 1079000 1024 x 1" Wafer #3.036.175 1/4''1/2'' 5,000 1547500 1024 x 11/4" PFH #3.036.175 1/4''3/4'' 5,000 1643100 1024 x 11/4" Wafer #3.036.175 1/4''3/4'' 5,000 1548500 1024 x 11/2" PFH #3.036.175 1/4''1'' 3,000 1644100 1024 x 11/2" Wafer #3.036.175 1/4''1'' 3,000 1082000 1024 x 17/16" *PFH #3.060.175 1/4''3/4'' 3,000 1588910 #2 PSD Bit 1 1552500 1224 x 15/8" *PFH #4.125.250 3/4''11/8'' 2,500 1092000 1224 x 21/4" *PFH #4.125.250 3/4''13/8'' 2,000 1094000 1224 x 23/4" *PFH #4.125.250 3/4''15/8'' 1,500 1096000 1/420 x 3" *PFH #4.125.250 3/4''2'' 1,000 * With wings ** With ribs under head Product Report No. 02705 Plywood, mansard, fascia, roofing, flooring to steel framing Plywood, 2 x 4 s headers to steel framing 2 x 4 s to steel framing Performance Data Fastener Dia. Pt. #1016 3 #1024 3 #12 4 1/4 4 PULLOUT VALUES (average lbs. ultimate) Steel Gauge 26 24 208 22 266 20 299 18 499 16 708 967 12 74 3/16 1/4 334 495 702 900 1570 3865 4101 1508 4297 1803 Fastener (diatpi) 1016 1024 1224 1/420 FASTENER VALUES Tensile Shear (lbs. min.) (avg. lbs. ult.) 1936 00 2702 1500 3165 2200 3860 2700 Torque (min. in. lbs.) 61 65 150 168 Gauge No. SHEET STEEL GAUGES 12 16 Decimal Equivalent.105''.075''.060''.048''.036''.030''.024''.018'' The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes. 18 20 22 24 26 SHEAR VALUES (average lbs. ultimate) Fastener Steel Gauge (lapped) Dia. #10 #12 1/4 Pt. 3 4 4 20 728 18 1266 16 1540 1522 12 2048 2650 1/8 2030 2820 Installation Guidelines A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 02500. Adjust the screwgun nosepiece to properly seat the fastener. Worn or damaged bit tip should be replaced. The fastener is fully seated when the head is flush with the work surface. Overdriving may result in torsional failure of the fastener or stripout of the substrate. The fastener must penetrate beyond the metal structure a minimum of 3 pitches of thread. All #10 diameter Winged parts must be driven into a minimum of 16 GA steel thickness. All 1/4 and #12 diameter Winged parts must be driven into a minimum of 1/8" steel in order to break the wings consistently. 1349 West Bryn Mawr Avenue Itasca, Illinois 603 6305953500 Fax: 6305953549 www.itwbuildex.com Teks, Climaseal and Spex are trademarks of ITW Buildex and Illinois Tool Works, Inc. Phillips Square Driv is a registered trademark of the Phillips Screw Company. 2010 ITW Buildex and Illinois Tool Works, Inc.

CARTRIDGES310mLSIZE SAUSAGEPACKS400mLSIZE