Screw Patterns Roof & Walls TR-36 MD-36 TSM-32. PBR-Panel
|
|
|
- Aubrey Dixon
- 9 years ago
- Views:
Transcription
1 Screw Patterns Roof & Walls Overlap Underlap ¾ 9 TR /8 6 MD ½ 8 TSM ¼ 12 PBR-Panel 36 Bottom Edge Screw Pattern apply to every profile except for MD36 (1 screw beside every rib) High wind or Low pitch applications Stitch Sheets Butyl Tape Overlap Underlap All roof and wall sheeting requires ¾ to screw to either ¾ plywood or 1x4 standard spruce strapping. Vapor barrier is recommended. (15 lb. felt or Feltex) 29ga 24 oc strapping (max 30 span between strapping) 26ga 48 oc strapping (max 48 span between strapping) TR36, MD36 and TSM32 is not recommended to be installed below a 2/12 pitch Page 1
2 Starting Panel Prevailing Wind Small Tab Closure Stack sheets for one side. Pre-drill sheets with 3/16 hole as per screw pattern. Drill no more than 25 sheets at one time. Starting the gable end away from the prevailing wind, set first panel. Alignment is critical. The first panel determines the alignment of all remaining panels on the roof. Small tab closure should be placed under the panel at the eave as the panels are installed. Make sure to screw through the closure. Fastener depth chart Correct Too loose Too tight Sealing matl. slightly visible at edge of metal washer. Assembly is water tight. Sealing matl. not visible, not enough compression to seal properly. Page 2 Sealing matl. Extruded beyond edge of washer.
3 Gable Trim Butyl Tape Miter gable trim at peak 3 Gable trim Always start gable trim at eave and work towards ridge. End lap gable trim a minimum of 3 inches. Butyl tape should be placed between the gable trim and the roof panel. Attach the gable trim to the roof panel with panel fasteners located 24 inches apart. Miter gable trim at peak of roof as required. Attach gable trim to fascia with panel fasteners every 24 inches. Page 3
4 Ridge Cap Ridge cap should be end lapped 6 inches at each end. Place large tab closure between the ridge cap and the roof panels. Attach ridge cap to rib of roof panel with screws on every rib along both sides of rib. Make sure to screw through closures. Large Tab Closure Ridge Cap Roof Panel Page 4
5 Hip Conditions Universal closure Roof panels Ridge cap Always start ridge cap at eave and work towards top ridge. End lap ridge a minimum of 6 inches. Cut roof panels on angle as necessary. Universal closure should be placed between ridge cap and roof panels. Attach ridge cap to roof panel rib using screws at each panel rib. Page 5
6 W-Valley Applications Ice & Water shield Emseal 12 3 (Make sure to screw through the Emseal) W-Valley Eave flashing Always start w-valley at eave and work towards ridge. Temporarily secure valley in place with small nails or flat screws. End lap w-valley a minimum of 12 inches. Cut roof panels on angle as necessary. Emseal closure should be placed under roof panels. Install fasteners on center on both sides of valley through panel and closure 3 inches back from edge of cut metal. Page 6
7 Side and Front Wall Building wall Install roof panel up to side wall of building. Butyl side wall flashing and install. Butyl tape Front wall flashing Building wall Gable trim Large tab closure Eave flashing Install roof panels. Install gable trims. Place large tab closure and install front wall flashings. Screw to ribs and make sure to screw through the closures. Page 7
8 Endwall Gable Trim Endwall Large tab closure Eave Large tab closure Install metal roof. Install endwall flashing at top where roof ends. Make sure to screw through the closures. Page 8
9 Flared Gable Emseal (Screw through closure) Small tab closure Install flared gable flashing. Keep metal roofing back 3 inches. Install emseal closure 3 inches back from metal roofing. Make sure to screw through the closure. Page 9
10 Transition Transition 12 Gable Trim Upper Roof Panels Transition Gable Trim Small Tab Closure Large Tab Closure Eave Lower Roof Panels Transition flashing should be used when the roof panels change pitch. Place the transition flashing over the lower roof panels. Large tab closure or universal closure should be placed between the lower roof panels and the transition flashing. Use screws to attach the transition flashing to the ribs of the lower roof panels. Install the upper roof panels over the transition flashing placing small tab closure or universal closure between the two. Attach the bottom edge of the upper roof with panel fasteners similar to the eave installation. Make sure to screw through the closures. Page 10
11 Hip 4.5 Hip 12 Upper Roof Panels.5 Hip Gable Trim Small Tab Closure Lower Roof Panels Large Tab Closure Hip flashing should be used when the roof panels change pitch. Place the hip flashing over the lower roof panels. Large tab closure or universal closure should be placed between the lower roof panels and the hip flashing. Use screws to attach the hip flashing to the ribs of the lower roof panels. Install the upper roof panels over the hip flashing placing small tab closure or universal closure between the two. Attach the bottom edge of the upper roof with panel fasteners similar to the eave installation. Make sure to screw through the closures. Page 11
12 Master Flash SELECT and TRIM... Choose appropriate Master Flash with opening at least 20% smaller than pipe diameter. If necessary trim opening to 20% smaller than pipe diameter. SLIDE... Slide Master Flash down over pipe. (A non-petroleum base lubricant will ease installation.) FORM... Press Master Flash down, bending it to conform to roof profile or roof irregularities. A blunt tool will help press flashing into tight roof angles. SEAL... Apply sealant between base and roof. FASTEN... Use fasteners to complete sealing. For UPC installation, fastener spacing may not exceed 1-1/2" (38mm). Page 12
13 Skylight / Chimney Cut opening in roof panel. At bottom of opening slit panels or cut and endlap roof panels. Cut, notch and bend skylight trim as required (see example). Use emseal or caulk to seal between roof panel and skylight trim. Cut and slit panel as shown slope Cut, notch and fold trim as shown Backpan Small tab closure Butyl Side wall Butyl slope Large tab closure Page 13
14 Chimney with cricket Cricket Metalworks Canada recommends that a cricket be built up slope of large chimneys to prevent snow build up and water ponding. Cover the cricket with roll valley or flatstock and flash to chimney with skylight trim or universal sidewall and universal endwall flashing. Page 14
15 End lap condition / Cutting of panels Panels should be end lapped a minimum of 6 inches. End laps should never be run in a continuous line. Stagger end laps at least 1 foot apart. Jobsite cutting of panels if required may be done with either nibblers or shears. If extensive cutting is involved the use of a circular saw equipped with a steel cutting blade is recommended. Cut panels with bottom side up. Be sure to remove the metal filing immediately. Butyl Tape Page 15
16 Roof Pitch Recommended minimum roof slope for TR-36 is 2:12. It must be applied at any end lap conditions and at all side lap conditions under 4/12 pitch. (Keep butyl tape back 3 inches. screw through the closure) Butyl tape 6 3 slope Page 16
17 Side Elevation With Overhang Metal Roof Sheet Small Tab Closure (Screw through closure) 1 Overhang Eave Soffit Soffit Jay Fascia Siding Jay Outside cornerside elevation off walls Wall Cladding Base Page-Buildings A
18 Side Elevation Without Overhang On Eaves Metal Roof Sheet Small Tab Closure (Screw through closure) 2 Overhang Eave Butyl Tape Roof Cladding Wall Cladding Base Gable Trim Wall Cladding Gable Elevation Without Overhang Eave Base Page Buildings-B
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels
INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels Grand Rib-3 / Multi-Purpose / Classic Rib Grand Rib-3 / Multi-Purpose / & Classic Rib Grand Rib 3 panels are a strong,
and Siding Effective Date 12/08 1
Application Manual for Metal Roofing and Siding Effective Date 2/08 Table of Contents General Information... 4 Required Tools... 4 Getting Started... 5 Important Notes... 6 Safety Precautions... 7 Panel
Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions
Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions All questions and concerns please call 904-696-9700 Discount Direct Metal Roofing Plus Rib metal roofing panels are a strong,
Installation Manual for STANDING SEAM ROOFING
Installation Manual for STANDING SEAM ROOFING Absolute Steel Toll Free 877-833-3237 / Phone 480-768-1618 / Fax 480-768-1514 www.metalroofingsource.com Standing Seam features approximately one-inch high
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
METAL ROOFING INSTALLATION GUIDE
METAL ROOFING INSTALLATION GUIDE MIGHTY-RIB PBR (R-Panel) Regardless of whether your roofing project is a new installation or a re-roof, and whether your building is residential, commercial or agricultural,
Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Standing Seam
Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME MATTERHORN Standing Seam System Components Placement G F J K I A. Standing Seam Panel B. Valley Cleat/Sidewall Counter Flashing D G B C A
Section Page Section Page
Western States Western Rib Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key
BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra 2000. Includes:
BRIDGE & SUPPLY COMPANY Installation Guide Ultra 2000 Includes: Ultra 2000 Installation Guide Stock Trim Profiles Ultra 2000 Trim Installation Guide Page 2 Table of Contents Ultra 2000 Profile, Colors
Metal Building Systems Installation and Flashings & Details Guide. Table of Contents
Table of Contents Section Page Notes to Designer/User..................1-2 Map of Typical Roof Conditions............3 Fastener Placement.......................4 Fastener Selection........................5
Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..
Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
Steel Roofing and Siding Information & Installation Guide
Back to Service Steel Roofing and Siding Information & Installation Guide Locally Owned and Operated in Woodburn, Oregon Wholesale Manufacturer of Steel Roofing, Siding & Trim Introduction Valley Rolling
Classic Products, Inc. ClickLock Standing Seam Installation Manual
Classic Products, Inc. ClickLock Standing Seam Installation Manual Classic Products, Inc. 8510 Industry Park Drive Piqua, OH 45356 800.543.8938 Table of Contents page Introduction 1. 1 Starter. 2. 1 Panels.
General Instructions and Guidelines
General Instructions and Guidelines Building Design and Construction To ensure adequate performance and longevity, protect metal panels from potentially corrosive situations and materials. When treated
DETAIL MANUAL. for Standing Seam. 2308 East 23rd Street Chattanooga, TN 37407. 1652 South Lee Hwy. Cleveland, TN 37311
DETAIL MANUAL for Standing Seam 1652 South Lee Hwy. Cleveland, TN 37311 2308 East 23rd Street Chattanooga, TN 37407 Best Buy Metals Standing Seam Roofing Panels Fig. 2 Standing Seam Panel Has 1 high nail-strip
Gerard Installation Manual Shingle Profiles
Gerard Installation Manual Shingle Profiles Granite Ridge Shingle Guardian Shingle March 2014 This Installation Manual is designed as an instructional tool to clearly depict to the contractor, installer,
VAIL Metal Shingles. Application Instructions. Custom-Bilt Metals 13940 Magnolia Ave. Chino, CA 91710
VAIL Metal Shingles Application Instructions 13940 Magnolia Ave. Chino, CA 91710 VAIL Metal Shingles Application Instructions When installing or walking on VAIL Metal Shingles: 1. OSHA fall protection
STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS
ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the
METAL ROOFING SYSTEM ORDERING & INSTALLATION SELF HELP GUIDE. Fabral, Inc 1
METAL ROOFING SYSTEM ORDERING & INSTALLATION SELF HELP GUIDE Due to product improvements, changes and other factors, Fabral reserves the right to change or delete information herein without prior notice
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
VERTICAL LOCK Table of Contents
Table of Contents TABLE OF CONTENTS Vertical Lock Product Data Sheet... 2 Vertical Lock Engineering Data... 3 General Information... 6 Material Testing... 7 Panel Overview... 8 Handling Material & Storage
!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
4572 N Old US 31, Rochester, IN 46975 Toll Free: 877-889-7802 Fax: 574-223-7846 www.ramcosupply.com DETAIL MANUAL. and guide to Ramco Supply products
4572 N Old US 31, Rochester, IN 46975 DETAIL MANUAL and guide to Ramco Supply products Metal Roofing and Siding Panels & Accessories 1 4572 N Old US 31, Rochester, IN 46975 Ramco Supply s RAM Roofing Panels
Product Catalog. Extreme Roofing, Inc. 2680 Rt. 982 Mammoth, PA 724.838.7695 www.extremeroofinginc.com
2012 Product Catalog Extreme Roofing, Inc. 2680 Rt. 982 Mammoth, PA 724.838.7695 www.extremeroofinginc.com 2 PH. 724.838.7695 Email. [email protected] Website. www.extremeroofinginc.com Fax.
Titan Old World Spanish Tile
Installation Guide Titan Old World Spanish Tile Titan Manufacturing Phone: 407-587-5492 Fax: (866) 859-8607 www.titanroofsystems.com Rev 70908 This document includes the recommended and suggested installation
Shelterguard Metal Roofing System Ordering & Installation Guide
Shelterguard Metal Roofing System Ordering & Installation Guide Specifications contained herein subject to change without notice or obligation to make changes in products previously purchased. Shelterguard
Shingle Installation Guide
Shingle Installation Guide Getting Started Dedicated to improving the environment, NewTech manufactures roofing tiles that are composed of up to 90% recycled post-industrial plastic. The manufacture of
300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO
INSTALL PEEL & STICK (P&S) GUSSETS WITH PRIMER AS PER MANUFACTURERS INSTRUCTIONS 2mm MIN GAP IN SHEATHING STEP 1 PLACE 100mm X 100mm PIECE OF P&S IN CORNER SO THAT IT IS 38mm INTO THE OPENING EACH WAY
Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems
The Butler MR-24 Standing Seam Roof Difference A comparison between metal roof systems Roof Systems Necessities Weathertight (don t leak!) Low maintenance Weathertightness Roof clips, seams, panel alignment
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
Preformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
Home Depot Direct Special Order Retail Pricing 26 Gauge Horizon 16 & Ultra Loc 16 West Coast Standard
HORIZON 16 SKU # Retail UOM Model # Description WEST COAST MARKETS BYO5 Minimum Length 5ft for Horizon 16 and Ultra Loc 271814 $2.43 LnFt 4912200 26ga Horizon 16 Painted Galvalume Special Pricing for Copper
GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.
GUIDE SPECIFICATION Manufacturer: DECRA Roofing Systems A Fletcher Building Company 1230 Railroad Street Corona, CA 92882 951-272-8180 phone 951-272-4476 facsimile www.decra.com SECTION 07314 [07 31 14]
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
HfHMD uses LP SmartSide siding and trim.
HfHMD uses LP SmartSide siding and trim. These products are: More durable than cement fiber board. Much more volunteer-friendly to install. When installed correctly, have a 5/50- year pro-rated warranty.
Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
LX STEEL BUILDING INSTALLATION MANUAL
LX STEEL BUILDING INSTALLATION MANUAL A complete guide to the installation of the Quicken Mfg. LX Building and its accessories Copyright 2015 Quicken Manufacturing Inc. 16454 SE Hwy 19 Cross City, FL 32628
Best Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
Minimizing Water Intrusion Through Roof Vents in High-Wind Regions
Minimizing Water Intrusion Through Roof Vents in High-Wind Regions http://www.fema.gov HURRICANE IKE RECOVERY ADVISORY Purpose: To recommend practices for minimizing water intrusion through roof vent systems
Directions For Applying Malarkey Laminate Shingles
S Laminate Shingle Instructions 1 Directions For Applying Malarkey Laminate Shingles GENERAL INSTRUCTIONS Install Malarkey laminate shingles according to building code and local amendments. To qualify
POST FRAME LIGHT GAUGE APPLICATION GUIDE
POST RAME LIGHT GAUGE APPLICATION GUIDE Lebanon, PA 888.339.0059 Bridgton, ME 888.339.0059 Howe, IN 866.562.3782 www.everlastroofing.com Post rame Light Gauge Guage Post rame Trim Table of Contents Light
CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000
CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000 Details and Installation Guide October 2013 All information, descriptions and dimensions in this manual are current at the time of printing. As always, Custom-Bilt
Chapter 9: INSTALLING ROOFING
9.1 LEAK BARRIER (ICE AND WATER SHIELD) 9.2 SHINGLE UNDERLAYMENT 9.3 INSTALLING GUTTER APRON AND GABLE D-EDGE 9.4 INSTALLING SHINGLES 9.5 RIDGE VENT AND CAP Tools needed by each volunteer: Hammer (16 oz.
KAHU RESIDENTIAL ROOFING RRKA DETAIL LIST
KAHU DETAIL LIST 00 / 24 COVER SHEET 01 / 24 ROOF RIDGE 02 / 24 SAWTOOTH RIDGE 03 / 24 SAWTOOTH EAVE 04 / 24 ROOF VALLEY 05 / 24 ROOF - CHANGE PITCH 06 / 24 EAVE WITH METALLINE FASCIA 07 / 24 EAVE WITH
How to Install UnderDeck The Original.
How to Install UnderDeck The Original. TOOLS: Chalk Line Caulk Gun Garden hose or water bucket Gloves Hammer or Screw Gun Power Mitre Saw with OSB Blade Pencil Pliers Safety Glasses Straight Edge / Carpenter
SHINGLE APPLICATION GUIDE
SHINGLE APPLICATION GUIDE CONTENTS 01. General conditions 01. Material requirements 02. Terms 07. Estimating shingle requirements 08. Roof preparation 10.Shingle application E version 2006 GENERAL CONDITIONS
CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application 9 - 1 -
CONTENTS General conditions Material requirements 3 Terms 4 Estimating shingle requirements 4 Roof preparation 6 Shingle application 9 Shingle Shingle application application guide guide - - b a 3a 3b
Installing the Sno-free Standing Seam System for Metal Roofs
Installing the Sno-free Standing Seam System for Metal Roofs SFP SSP CLIP SSP STANDING SEAM SFP EXTRUSION SFP RAMP PANEL Step # 1 Mark the location and Install Extrusion Mark the area on the roof to receive
Retrofitting an Insulated Cold Roof
Retrofitting an Insulated Cold Roof As a metal-roofing contractor in the Upper Peninsula of Michigan, I am frequently asked to fix roof leaks that have less to do with roofing than with the way poorly
PRO-PANEL II. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information
Table of ontents Product Page No. Product Page No. Panel Information Profile... PPP-2 Panel Overview... PPP-2 Flashing Profiles Eave (Direct Fasten)... PPP-3 leat... PPP-3 Box Gutter... PPP-3 Box Gutter
STEEL BUILDINGS RECOMMENDED INSTALLATION GUIDE
STEEL BUILDINGS RECOMMENDED INSTALLATION GUIDE 3 TO 30 METRE SPAN TILT UP METHOD SUPPLIED BY: Last update 8 December 2010 2010 FBHS (Aust) Pty Limited FBHS (Aust) Pty Limited ABN 83 126 232 504 trading
How To Build A Gambrel Roof And A Gable End Roof
Dutch Gable or Gambrel Roof and The Scotch Valley The folowing pages are an extract from Carp 12 text TAFE NSW Construction and Transport Division 71 HIP and VALLEY ROOFING GAMBREL / DUTCH GABLE The effect
PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
Detached accessory structures that contain no conditioned floor area are exempt.
RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of
Plans will call for one of two soffit/fascia details:
Plans will call for one of two soffit/fascia details: Ventilated vinyl soffit with bent aluminum fascia OR Ventilated LP Smartside soffit panels with 1x6 rabbeted fascia First, let s talk terminology:
Superform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
Chapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
Common Errors in Truss Design
In today s competitive world of trusses, component manufacturers are always looking for ways to generate more efficient truss designs. Occasionally, truss designs need to be changed in order to be sealed
SECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof
ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
Cedar Cottage Doghouse Plans
Overlapping cedar shingles add an element of charm to this medium size doghouse. The walls, floor, and trim are constructed of solid cedar, making it naturally weather resistant and provides excellent
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
G VYCOR DECK PROTECTOR
G VYCOR DECK PROTECTOR Self-Adhered Flashing Contractor s Guide DECKS AND DETAIL AREAS For longer lasting decks, install Grace Vycor Deck Protector. FROM THE MAKERS OF G Ice & Water Shield What Self-Adhered
Handling, Erection and Bracing of Wood Trusses
Handling, Erection and Bracing of Wood Trusses Follow these guidelines for safe installation of Wood Trusses. These guidelines should not be considered to be the only method for erecting and bracing of
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
LokSeam. Design/Installation Information. This booklet includes: Trims and Accessories Design and Installation Information
LokSeam Design/Installation Information This booklet includes: Trims and Accessories Design and Installation Information Since 1908 ABC has developed a strong reputation by providing top quality reliable
Installation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
Standing Seam Roof Systems
Standing Seam Roof Systems REAL PEOPLE. REAL PRODUCTS. REAL SOLUTIONS. www.a-s.com Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per
ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof
ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find
Guide to Safe Building Practices
Guide to Safe Building Practices Guide to Safe Building Practices This is a guide for tradesmen, builders and contractors to help them build, repair and retrofit buildings and particularly roofs, with
AMERICAN GOTHIC PLAYHOUSE
AMERICAN GOTHIC PLAYHOUSE Project Plan #856 Sheet 1 of 5 Pick a spot and get started with the beautiful that your kids will love. The design of the playhouse includes 35 square feet of interior space plus
ABSeam Panel Overview and Installation Instructions
82 Garden Spot Road Ephrata, PA 17522 717-445-6885 35 Ridge Road Newville, PA 17241 717-776-5951 ABSeam Panel Overview and Installation Instructions Applications: The ABSeam panel is an architectural panel
Section A Roof Truss
Section A Roof Truss Truss Types Wisconsin Truss, Inc. can build a variety of truss types, pictured below are some common examples. Common Bobtail Scissor Mono Studio Dual Slope Cathedral Tray Vault Parallel
GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.
GUIDE SPECIFICATION Manufacturer: DECRA Roofing Systems A Fletcher Building Company 1230 Railroad Street Corona, CA 92882 951-272-8180 phone 951-272-4476 facsimile www.decra.com SECTION 07313 [07 31 13]
Multi-Width Shake. Widths: 9", 8", 7", 6", 4" Length: 22" Thickness at butt: 5/8" Single-Width Shake. Widths: 9" Length: 22" Thickness at butt: 5/8"
N DaVinci Shake Multi-Width Shake Single-Width Shake INSTALLATION GUIDE DaVinci polymer shakes are carefully engineered to provide the authentic look of hand-split shakes with dramatically increased durability
Brick Veneer Construction
Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power
Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows
Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows Viewed from the exterior. IMPORTANT: Please read before you begin installation. TABLE OF CONTENTS AND TOOL / MATERIAL
HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
THE DEWALT RAFTER SQUARE
THE DEWALT RAFTER SQUARE The DEWALT Rafter Square is designed to provide a quick, accurate, and repeatable means for laying out and cutting the various cuts on common, hip, valley and jack rafters used
SECTION 07320 ROOFING TILE
SECTION 07320 ROOFING TILE PART 1 - GENERAL 1.1 SUMMARY: A. Section Includes: 1. Vitrified clay roofing tiles. 2. Tile accessories. 3. Felt underlayment. 4. Self-adhering sheet underlayment. 5. Snow guards.
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
Historical Information
Historical Information The use of gutters, or eaves troughs, dates from early colonial times when two boards were nailed together to form a functional V-shaped trough placed below the drip edge of the
There s a LYSAGHT walling solution to suit every Australian building. Walling Solutions 2PF300 PAGE 1
Walling Solutions There s a LYSAGHT walling solution to suit every Australian building. 2PF300 PAGE 1 LYSAGHT Walling Products Scope. Walling Design Maintenance PAGE 2 Materials and finishes Typical material
Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.
PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation
K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11
K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins
When considering Roof drainage design the following should be taken into account:
Roof Drainage Design The primary objective of a gutter or spouting system is to remove water from the roof catchment area and channel that water to the ground drainage. Water ingress can have detrimental
WHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
SL-16. Concealed Fastener System. This booklet includes: Trims and Accessories Design and Installation Information
SL-16 Concealed Fastener System This booklet includes: Trims and Accessories Design and Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF ANY
SL 16. Concealed Fastener System. This booklet includes: Trims and Accessories Design and Installation Information
SL 16 Concealed Fastener System This booklet includes: Trims and Accessories Design and Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE