Siemens tiastar TM Motor Control Center (MCC) Siemens 2011. All rights reserved.



Similar documents
UL Validated Testing of Arc-Resistant Motor Control Centers

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Low Voltage Switchgear

Enhancing Personnel Safety with Arc Resistant Equipment

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Power-Zone 4 Arc Resistant Low Voltage Switchgear

How to reduce exposure to arc flash hazards

2008 Eaton Corporation. All rights reserved.

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Vilter motor starter solutions The NEW industry standard in motor starter packages

Arc Terminator Active Arc-Resistant Switchgear

Bypass transfer switch mechanisms

Medium Voltage Motor Control Assemblies

Permissible ambient temperature Operation Storage, transport

ELECTRICAL SAFETY RISK ASSESSMENT

Table of Contents. Review Answers...77 Final Exam...80

Industrial OEM products

Paralleling Switchgear

SENTRON Switching and Protection Devices Air Circuit Breakers

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

Safety Requirements Specification Guideline

misconceptions about arc-flash hazard assessments

Fusible Disconnect Switch

Choosing the Best Solution for Reducing Arc Energy

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

New standardized approach to arc flash protection

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Unified requirements for systems with voltages above 1 kv up to 15 kv

SECTION VARIABLE FREQUENCY DRIVES

The following components are common to most cubicles; this example is an ABB HK cubicle.

Specifying a Variable Frequency Drive s

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Arc Flash Mitigation & Selective Co-ordination

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

Process Alarm Solutions

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Use your troubleshooting superpowers for good Application Note

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Safety By Design. Strategies for Electrical Contractors

Comprehensive Range of Industrial Products and Solutions

C o v e r. Thin Client Application Options. SIMATIC Thin Client s FAQ h April 2009 e et. Service & Support. Answers for industry.

Low Voltage Switchgear MNS is with MSpeed

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Understanding Arc Flash

MCC Ratings. Voltage Rating

MNS is Switchgear System Technical Overview

Understanding the Standards Surrounding Arc Flash Hazards and Arc Resistant Equipment

The Intelligent AX1 Switchgear for Medium Voltage

Ralf Christian, CEO Low and Medium Voltage. Making Things Right with Totally Integrated Power (TIP)

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Arc Flash Energy Mitigation Techniques

Charging what can be more simple? SAE J1772

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

Parameterization, Configuration and Visualization with SIRIUS

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

New Perspectives with SIMATIC PCS 7 Process Control System SIMATIC PCS 7. Answers for industry.

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Catalog. Arc Guard System TM TVOC-2

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

, User s Manual

New Arc Resistant, Compact Metal Clad Switchgear: Meeting ANSI / UL Design Challenges By Ashok Kulkarni and Predrag Milovac

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

Technical Guide. SKM Arc Flash Line Side vs. Load Side

Intelligent Vibration Monitoring

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Sample - No Commercial Use

Oil and Coolant Circulating Heating System. Model - OCSM

Eaton s E-Series protective relay family

What s up with Arc Flash?

SmartVFD HVAC and BYPASS

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Intelligent Device Management with DCS, PLC, and RTU

Introduction to the Actuator Sensor-Interface

Understanding Emergency Power Off (EPO)

Easy and efficient asset management for your business

Introduction To SCADA and Telemetry

Metering for today s systems

Number 1 in efficiency

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

Increasing safety, reliability and efficiency for today s data centers

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Medical Vacuum Systems-PXMI

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

Electrical Symbols and Line Diagrams

Transcription:

Siemens tiastar TM Motor Control Center (MCC) Siemens 2011. All rights reserved.

tiastar Arc Resistant MCCs UL Validated Testing of Arc-Resistant Motor Control Centers page 2

tiastar Arc Resistant MCCs Statistics Arc flashes are responsible for about 80 percent of electrical accidents in the U.S. each year 1. In human terms, they are responsible for hundreds of deaths, thousands of serious injuries, and significant lost work time every year. 2 Bureau of Labor Statistics Census of Fatal Occupational Injuries page 3

tiastar MCCs Arc Flash Arc flashes are responsible for about 80 percent of electrical accidents in the U.S. each year. Personal Protective Equipment (PPE) can help avoid or reduce the severity of injuries Electrical equipment manufacturers have applied strengthened structural design to improve the safety potential of its Switchgears. Standards for performance-testing arc-resistant features defined for switchgear not MCCs. Manufacturers are using those standards for testing arc-resistant MCCs. page 4

tiastar Arc Resistant MCCs Prevention The simplest and most effective measure to prevent an arc flash is to shut off all power to the equipment to be worked on. Siemens advises that individuals should only work on MCCs or other electrical equipment after all power to the equipment has been turned off. Arc flash prevention, safety training and PPE can only go so far in keeping workers out of harm s way should an arc fault occur. Although PPE can provide protection from an arc flash, it still cannot protect an operator from being struck by enclosure doors blown off or open from an arc flash or from fragments ejected from a disintegrating enclosure. page 5

tiastar Arc Resistant MCCs Arc Mitigation & Arc Resistant Equipment Arc flash hazard mitigation and arc-resistant features. Designed to complement each other. Arc flash mitigation features: To keep the workers beyond the Arc Flash Boundary To shorten the arc flash duration Arc resistant equipment: To make sure that, in the event of an arc flash when the MCC s doors are closed and latched, the equipment will contain the explosion, directing the arc blast, including its heat, plasma and pressure, away from workers. page 6

tiastar MCCs Arc Flash Mitigation Arc Flash Hazard Mitigation Features available in tiastar MCC: Dynamic Arc Flash Sentry (DAS): This is a patented feature available in both Siemens MCCs and type WL Low Voltage Switchgear. DAS (alternate parameter settings) can be activated using a variety of activation methods (keyed switch, occupancy sensors, light curtains, etc.). Visual verification of DAS activation can be as simple as a pilot light or more elaborate such as horn and strobe light. page 7

tiastar Arc Resistant MCCs Arc Flash Mitigation Normal Operation Parameter A Maintenance Operation Parameter B page 8

tiastar Arc Resistant MCCs Arc Flash Mitigation page 9

tiastar Arc Resistant MCCs Siemens is the first manufacturer in the industry to have Underwriters Laboratories (UL) observe and validate the testing of its arcresistant tiastar TM MCC model. The tiastar arc-resistant MCC successfully met the testing criteria required by the standards, and a qualified, independent third-party has confirmed this satisfactory performance. page 10

The new tiastar product family: tailor made feature sets focused on your industry Base HD H2O Smart Your Industry Construction Commercial Offshore O&G Real estate Warehouses Municipal W/WW Process Industries Pharmaceuticals Why Tiastar Fastest shippingat lowest price point Smallest footprint with highest safety and performance Arc-Resistant MCC Always-on reliability, industryleading asset protection Always on, autonomous backup (failover), automatic process adjustments page 11

tiastar Arc Resistant: Features that reach farther Arc Flash Resistant Setting a new safety standard, tiastar is the first IEEE C37.20.7 compliant arc resistant motor control center with UL-witnessed testing. Decrease the risk of exposure to arc flash incidents to better protect personnel. page 12

tiastar Arc Resistant: Protecting your most valuable asset your personnel Reinforced enclosure and doors, with bolted rear covers: Increased hinge and latching locations combined with additional structural supports ensure sections will withstand, contain and re-direct internal arcing fault incident energy. Insulated vertical bus bar system: Isolates energized components preventing inadvertent contact and propagation of arcing faults. Automatic shutters in plug-in unit compartments: Isolates the plug-in location to prevent inadvertent access and lowers the risk to personnel. Internal venting system: The structure components are designed to vent and channel arc flash gasses to the back and out the top of the MCC. page 13

tiastar Arc Resistant MCCs Features ANSI/IEEE Type 2 arc resistance to protect personnel at the front, back and sides of the equipment Reinforced enclosure to withstand pressure from internal arcing faults Internal venting system with pressure vents to channel the flow of arc fault gases and vent these gases out the top of the gear and away from personnel page 14

tiastar Arc Resistant MCCs Features Reinforced front with doors with extra hinges and stronger latching systems Reinforced bolted rear covers page 15

tiastar Arc Resistant MCCs Features Insulated bus bar system Automatic Shutters page 16

tiastar Arc Resistant MCCs Features Arc flashes present a serious safety risk. The best protection is prevention by enforcing strict safety rules, mandate proper maintenance, and support that with regular safety training. Advances in technology have enabled electrical equipment the means to design and engineer much more arc flash safety features into their products and systems such as switchgear and MCCs. While standards continue to evolve, they inherently follow these kinds of innovations. It is important that the application testing of new safety features be validated by a qualified third-party like UL to ensure that the safety features work as intended and to prevent tragic accidents. page 17

Smart Motor Management Siemens 2011. All rights reserved.

Smart MCCs What is a Smart MCC? A smart MCC can communicate via a network by incorporating intelligent devices to: control motors monitor motor operation monitor energy consumption monitor power quality monitor system operation communicate with a data network page 19

Smart MCCs Monitoring System Operation Historically MCCs have played a limited roll in monitoring system operation. providing basic information to the PLC M OL Example - start-stop motor control circuit PLC inputs are connected to normally open auxiliary contacts. M contact closes when the motor starter coil energizes. OL contact closes when an overload occurs. page 20

Smart MCCs Monitoring System Operation Historically basic information to the adding to the initial cost of the system Conventional Wiring for 1 motor starter (5 wires minimum) ON OFF FAULT Motor RUN Output Motor Starter Run and Trip Input Signals Remote PLC /DCS page 21

Smart Motor Control Centers: What is the cost? Motor Starter 5 Motors 25 Wires Remote PLC / DCS Motor Starter Remote PLC / DCS Motor Starter Remote PLC / DCS Motor Starter Remote PLC / DCS Page page 22 22 Motor Starter Remote PLC / DCS

Smart Motor Control Centers: What is the cost? Page page 23 23 25 Motors 125 Wires

Smart Motor Control Centers: What is the cost? Page page 24 24

Smart MCCs Monitoring System Operation Historically basic information to the PLC adds to the initial cost of the system PLC wiring labor page 25

Smart MCCs Monitoring System Operation Historically Increase system complexity Increase the number of wires Increase cost to gain limited information NOW Smart MCCs incorporate intelligent devices Providing expanded protection to motors Communicate information previously difficult to obtain or unavailable Motor Operation Power Conditions Status of External Events page 26

tiastar Smart MCCs Network Communication PROTOCOL Many different protocol exist PROFIBUS PROFINET Industrial Ethernet AS-Interface PROFIBUS DP is the primary network used internal to a tiastar SMART MCC PROFIBUS DP is an open network based on the IEC 61158/61784 standard. page 27

Smart Motor Control Centers: What is the cost? Page page 28 28 Assuming 25 starters and 100 between mcc units and the PLC/DCS: (25) SIMOCODEs (0) Starter aux. contacts (0) Overload alarm contacts (0) Digital PLC input points (0) Digital PLC output points 200 feet PROFIBUS cable and connectors Approximately $12500

tiastar Smart MCCs Monitoring System Operation Intelligent Components Simocode VFD Power Meter WL CB RVSS page 29

tiastar Smart MCCs Pro C The compact system for: Direct starters Reversing starters SIMOCODE Siemens Motor Management and Control Device Pro V The variable system for: all control functions extendable additional functions page 30

tiastar Smart MCCs Monitoring System Operation Conventional Information Additional desirable information, such as ON WARNING FAIL TO START UNDER LOAD OFF JAM PHASE LOSS OVER TEMP FAULT AUTO CONTROL POWER??? Typically not provided on most motors due to cost page 31

tiastar Smart MCCs Application: Electrical + Spannungserfassung pump (up to 550 kw) Configuring Operator Station of the application within SIMOCODE pro possible Application remains available during fails of the automation or communication system Profibus interface is the standardized interface between Engineering Station Maintenance Station Power Management application and automation system SIMOCODE pro Basic unit - Protection - Control - Interlockings - Monitoring - Communication Temperature module Analog module Digital modules Protection against overload, stall, phase failure, Monitoring of power, Cos-Phi motor idling, rotational direction Temperature monitoring e.g. of the bearings, windings, medium, cooling fluid Monitoring e.g. of the filling level, filter dirt, flow rate, run dry protection, Pressure of the cooling fluid or gear oil Monitoring/Status e.g. overflow, run dry protection, Check-back signals: Open, Closed, On, Off page 32 Pump Flow rate Filter

tiastar Smart MCCs Siemens Motor Management and Control Device PARTIAL LIST OF INFORMATION AVAILABLE MOTOR OPERATION POWER CONDITIONS STATUS OF EXTERNAL EVENTS OPERATIONAL STATUS PHASE CURRENTS DISCRETE INPUTS NUMBER OF STARTS PHASE VOLTAGES ANALOG INPUTS OPERATING TIME PHASE FAILURE RESULTS OF INTERNAL LOGIC STOP TIME NUMBER OF FORWARD STARTS NUMBER OF REVERSE STARTS MOTOR/BEARING TEMPERATURE NUMBER OF OVERLOAD TRIPS TIME TO TRIP PHASE IMBALANCE GROUND FAULT ENERGY CONSUMED REAL POWER APPARENT POWER POWER FACTOR LAST TRIP CURRENT COOL DOWN PERIOD page 33

tiastar Smart MCCs Process Visualization and Control integration to a larger system SIMATIC WinCC SCADA system Configurable to provide complete operating and monitoring functionality SIMATIC PCS 7 uniform data management, communication, and configuration capabilities open platform for solutions in batch, continuous, and hybrid process applications page 34

Data Record Capability with Simocode ES software or S7300 PLC page 35

Data Record Capability with S7400 PLC with PCS7 Limits -current limits Maintenance -Local/Remote Standard -Control Statistic Alarm - PCS7 Alarm logging Trend Faults Warnings Batch Control - PCS7 Batch Control page 36

tiastar Smart Start A truly plug-n-play option for tiastar Smart. Fully operational the moment you switch it on. Faster Start: Pre-programmed, pre-configured and pre-tested PLC and HMI combination reduces field engineering and commissioning times for quicker installation. Fast Access: Standardized PLC and HMI offer instant access and control of all the information in every PROFIBUS device from the moment the unit is switched on. Users can start, stop, test and verify all motor operations immediately after installation. page 37

Smart Start Elevation Configuration page 38

Smart Start Main Screen, SIMOCODE View page 39

Smart Start Main Screen, Variable Frequency Drive View page 40

Smart Start Main Screen, RVSS View page 41

Siemens tiastar Motor Control Centers Base HD H2O Smart Arc-Resistant Designed to meet your application requirements page 42

The new tiastar product family Base Attractive Price Point & Lead Times HD Smallest Footprint Arc Resistant Increased Operational Safety H20 Integrated Drives Smart Diagnostics & Fast Start up page 43

Totally Integrated Automation and Totally Integrated Power Field instrumentation Process analyzers Process control system SIMATIC PCS 7 PLC (SIMATIC S7) HVAC MES (SIMATIC IT) TIA Drives (SINAMICS) Medium Voltage Switchgear WL Low Voltage Switchgear TIASTAR Motor Control Centers ACCESS Power Monitoring TIP ERP Enterprise Resource Planning MES Manufacturing Execution Systems Automation >=110kV Medium Voltage Low Voltage page 44

Smart Motor Control Centers: What is the cost? Assuming 25 starters and 100 average per wire length, the traditional wiring solution requires: (25) Starter aux. contacts (25) Overload alarm contacts (50) Digital PLC input points (25) Digital PLC output points 12,500 feet interconnect wire Approximately $12500 (components, wire, installation) Page page 45 45