In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).



Similar documents
PAINT BOOTH LIGHTING

REVO-LB. REVO LB (Low Bay Industrial Luminaires)

Metal Halide Pulse Start vs. Probe Start. By Dick Erdmann GE Specification Engineer

Dialight LED Lighting Fixture Catalog. for Indoor and Outdoor Industrial and Hazardous Locations

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

commercial LUMINAIRE COMPONENTS WARRANTIES MADE IN CANADA MU-AL MU-AN

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

DuroSite TM High Bay Lighting

Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications

Invue ECM/EMM EPIC MEDIUM W

Dialight LED Lighting Fixture Catalog. for Industrial and Hazardous Locations

PPL Electric Utilities Energy Efficiency and Conservation Program

induction lighting toll free: tel: fax:

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications.

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

commercial HID lighting table of contents LIGHTING

Kolorlux. GE Lighting DATA SHEET

8146/5 Series Breaker Panelboards

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Standard Finishes: Copper-free aluminum epoxy powder coat Krydon material high reflectance white Stainless steel natural

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Multi-Vapor Metal Halide Lamps

V anguard. applications 5.1. vanguard vanguard. Assembly lines. Production areas. Gymnasia. Swimming pools. Clean areas. Food processing areas

Property Risk Management HIGH INTENSITY DISCHARGE ELECTRICAL LIGHTING

DuroSite TM Series LED High Bay. for Industrial & Commercial Applications.

Understanding LED Drivers

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

IPS HIGH-BAY / LOW-BAY LIGHTING

Retrofit HID High Bay Fixtures to Long Life High Efficiency LED

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Champ VMV Series. 3,000 to 25,000 lumen LED high bay luminaires. LED luminaires for hazardous areas

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

SYLVANIA METALARC Pulse Start Metal Halide Lamps

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

Evolve LED Garage Light

Abtech Custom Solutions

SafeSite LED RTO Area Light - UL844. for Indoor and Outdoor Industrial Applications #

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

KATO. LED Lighting High Bay und Low Bay

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are:

Linear Luminaire with LED Series EXLUX 6402/2

DuroSite LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

INFRARED RADIANT HEATERS. air heaters

Optilux LED Low Bay and High Bay. Optilux CFL Low Bay. Low Bay. High Bay. IP65 High Bay

Guide to new, energy-efficient lighting technologies for your business

Evolve LED Roadway Lighting

design Mario Cucinella MAXIWOODY

SKYGUARD. Prisma design. H max 2,5 m. H min 0,46 m.

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

PGL5/6 - Parking Garage Luminaire Installation Instructions

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index

Industrial Luminaires

V A P O R P R O O F b y D e s i g n

5YR. Advanced LED lighting. High performance industrial lighting. 50% energy against traditional fittings Up to 75% energy saving with sensing

High Bay Occupancy Sensor Selection Guide

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

Weatherproof Products

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting

LED Tubular Lamp / Kit Guide

LED High Bay FBX. An economical LED high bay Enjoy flexibility and savings along with quality illumination

Lutron High Bay Fixture Solutions

Nightscape High performance floodlights and spotlights for discharge lamps

morelux QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04

DuroSite TM LED High Bay. for Industrial & Commercial Applications.

INDUSTRIAL & SPORTS LIGHTING

Applications. Architectural

LED High Bay Light 100W

LITTLETON / ENGLEWOOD WASTEWATER TREATMENT PLANT. L/E WWTP Lighting Improvement 2015 Project Manual S Platte River Drive Englewood CO 80110

T5 LongLast. GE Lighting DATA SHEET

IVIOS LED III. LUM Technical Information

Explosion-Proof Electric Unit Heaters

Emergency Light Fittings

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

HANDY INFORMAL LIGHTING GLOSSARY

Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps

LOWBAY INDUSTRIAL LIGHTING

Low / High Bay Datasheet

LED High Bay with LexaLite S16 and S22 Reflexors

ORDER DIRECTLY TODAY AT:

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Energy efficient lighting for your home find out more.

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

ConstantColor CMH MR16

AUTOMOTIVE LED LIGHT CATALOG

120W High Bay II Datasheet

C2D LowBay: All the power, none of the bulk. C2D Advantage

IN-GRADE C54 Accent 6350 HID Accent 6360 Cool-Lens. Well Lights Watt HID Up to 150 Watt Halogen or Incandescent

Features. High Brightness LED Light source

Evolve LED Area Light

JD(Doug) Rooks Western Area Applications Manager

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

Transcription:

TEMPERATURE PROFILE DATA In the following Temperature Profile Data Charts, when a column is headed Tested Lamp Envelope Surface Temperature in C @ 40 C Maximum Ambient, the data (in degrees Celsius) was obtained in a 40 C ambient under normal gravity conditions. In the following Temperature Profile Data Charts, when a column is headed Maximum Luminaire External Surface Temperature in C, the data (in degrees Celsius) was obtained under a dust blanket at 40 C ambient under normal gravity conditions. In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius). TEMPERATURE CODE IDENTIFICATION IDENTIFICATION NUMBER DEGREES C NUMBER DEGREES C MAXIMUM T1 450 T3A 180 TEMPERATURE T2 300 T3B 165 RANGE T2A 280 T3C 160 IDENTIFICATION T2B 260 T4 135 NUMBER T2C 230 T4A 120 T2D 215 T5 100 T3 200 T6 85 Page-1 1-8 8 8-6 9-4 3-5 3 3 OLP-2911

POWR GARD H9 TEMPERATURE PROFILE DATA Data applies to Globe and Guard with or without Standard Dome or Angle Dome Reflector (Class I and II), Deep Dome (Class I only). Pendant Angle Stanchion Floodlight Flexible Pendant Wall Ceiling Straight Stanchion Class I, Class II, Class I, Class II, Class I, Division 1 Division 1 Division 1 Division 1 Division 1 Groups C,D Groups C,D Groups C,D Lamp Max Ambient Temp Temp Temp Temp Temp Wattage C 50 55 T5 T4 T5 T4 T4 70 55 T5 T4 T5 T4 T4 100 55 T5 T4 T5 T4 T4 150 55 T4A T4 T4A T4 T4 200 55 T3C T3 T3C N/A T3C 250 55 T3C T3 T3C N/A T3C 400 40 T3* N/A T3A* N/A T3A* METAL HALIDE AND PULSE METAL HALIDE** 100 55 T4A T4A T4A T4A T4 250 55 T3C N/A T3C N/A T3B* 400 40 T3A N/A T3A N/A T3* QUARTZ OPTION Automatically switched quartz. Available only with lamp types and wattages shown below. Maximum ambient is 40 C. Limited to 150-watt quartz lamp. Cannot be used for Paint Spray area. Data applies to Globe and Guard with or without Standard Dome or Angle Dome Reflector (Class I and II), Deep Dome (Class I only). Pendant Straight Stan- Flexible Pendant chion Wall Angle Stanchion Ceiling Straight Stanchion Class I, Division 1 Class II, Division 1 Groups C,D Lamp Max Temp Temp Wattage Ambient C 50 40 T3C T3C 70 40 T3C T3C 100 40 T3C T3C 150 40 T3C T3C 200 N/A N/A N/A 250 N/A N/A N/A 400 N/A N/A N/A METAL HALIDE 100 N/A N/A N/A 250 N/A N/A N/A 400 N/A N/A N/A NOTE: *CAUTION: Operating temperatures exceed safe temperatures for some Group C materials. To prevent fire or explosion install only as intended. **For PMH, cannot use with Deep Dome Reflector, contact factory for complete restrictions. LIMITATIONS H9 luminaires are UL Listed for Class I, Division 1, Group C (180 C max) and Group D (280 C max) luminaire surface temperature. H9 luminaires are not for Groups A and B. WARNING Do not use GE Multi-Vapor II MXR175 lamps in explosion proof or hazardous duty fixures because they have higher bulb temperatures than standard 175-watt metal halide lamps and may exceed the temperature rating of these fixture types. H8 HAZARDOUS LOCATION INCANDESCENT LUMINAIRE UL844 YOU MUST USE TEMPERATURE PROFILE DATA TO PROPERLY SELECT LUMINAIRE TEMPERATURE PROFILE (25 C AMBIENT) DATA APPLIES TO ALL Maximum Wattage No Standard Angle Temp Classification Group Reflector Reflector Reflector Class I, Division 1 C, D 300 300 300 T3C Class I, Division 1, 2 D (Paint 75 N/A N/A T4A Spray) Class II, Division 1 E, F 200 150 200 T3 Class II, Division 1 E, F, G 100 N/A 150 T3C Class II, Division 2 G 100 N/A 150 T3C NOTE: N/A=Not Applicable Page-2

FILTR GARD H2 AND H2U TEMPERATURE PROFILE DATA Large Globe and Guard (Type FG) (with or without Standard Dome or Angle Dome Reflector) 250 Watts Maximum All Mounting Arrangements Usable with all H2 Mounting Arrangements except NOT FOR ANGLE STANCHION mounting unless following conditions are met: For Class II and Class III, Divisions 1 and 2, angle stanchion can be used with globes in combination with 50-, 70- and 100-watt High Pressure Sodium light source only. Temperature code is T3C except with deep dome (see data) with small or large globe. No other High Intensity Discharge (HID) light source can be used with angle stanchion and globe for this classification. Class II, Division 1, ; Class II, Division 2, Group G; and Class III, Divisions 1, 2 Groups E, F Group G Max Max * Max * Maximum Max Maximum Max Ambient Ambient Ambient Luminaire Ambient Luminaire Ambient Lamp 40 C 55 C 65 C External 40 C External 40 C Wattage Temp Temp Temp Surface Temp Surface Temp Temp ( C) Temp ( C) 50 T3A T3 T3 160 T3C 160 T3C 70 T3A T3 T3 160 T3C 160 T3C 100 T2D T2C T2C 160 T3C 160 T3C 150 T2A T2 T2 200 T3 N/A N/A 250 T1 N/A N/A N/A N/A N/A N/A 100 T2A N/A N/A 200 T3 N/A N/A 175 T2A N/A N/A 200 T3 N/A N/A 250 T1 N/A N/A N/A N/A N/A N/A 400 N/A N/A N/A N/A N/A N/A N/A Large Globe and Guard (Type FG) (with Deep Dome Reflector) 250 Watts Maximum Class II, Division 1 Groups E, F Maximum Max Luminaire Ambient Lamp Maximum External 40 C Wattage Ambient 40 C Surface Temp Temperature Temp ( C) 50 T3C 200 T3 70 T3 200 T3 100 T2B 200 T3 150 T2B 200 T3 250 T1 N/A N/A 100 T2 N/A N/A 175 T2 N/A N/A 250 T1 N/A N/A 400 N/A N/A N/A Small Globe and Guard (Type GG) (with or without Standard Dome or Angle Dome Reflector) 175 Watts Maximum All Mounting Useable with all H2 Mounting Arrangements except NOT FOR ANGLE STANCHION Arrangements mounting unless following conditions are met: For Class II and Class III, Divisions 1 and 2, angle stanchion can be used with globes in combination with 50-, 70- and 100-watt High Pressure Sodium light source only. Temperature code is T3C except with deep dome (see data) with small or large globe. No other High Intensity Discharge (HID) light source can be used with angle stanchion and globe for this classification. Class II, Division 1, ; Class II, Division 2, Group G; and Class III, Divisions 1, 2 Groups E, F Group G Max Max * Max * Maximum Max Maximum Max Ambient Ambient Ambient Luminaire Ambient Luminaire Ambient Lamp 40 C 55 C 65 C External 40 C External 40 C Wattage Temp Temp Temp Surface Temp Surface Temp Temp ( C) Temp ( C) 50 T3A T3 T3 160 T3C 160 T3C 70 T3A T3 T3 160 T3C 160 T3C 100 T2B T2C T2C 160 T3C 160 T3C 150 T2A T2 T2 200 T3 N/A N/A 250 N/A N/A N/A N/A N/A N/A N/A 100 T2 N/A N/A N/A N/A N/A N/A 175 T2 N/A N/A N/A N/A N/A N/A 250 N/A N/A N/A N/A N/A N/A N/A 400 N/A N/A N/A N/A N/A N/A N/A Small Globe and Guard (Type GG) (with Deep Dome Reflector) 250 Watts Maximum All Mounting Arrangemnets Class II, Division 1 Groups E, F Maximum Max Luminaire Ambient Lamp Maximum External 40 C Wattage Ambient 40 C Surface Temp Temperature Temp ( C) 50 T3C 200 T3 70 T3 200 T3 100 T2B 200 T3 150 T2B 200 T3 250 N/A N/A N/A 100 T2 N/A N/A 175 T2 N/A N/A 250 T1 N/A N/A 400 N/A N/A N/A * Standard max Ambient Temp is 40 C for 55 C or 65 C, contact factory. Page-3

FILTR GARD H2 AND H2U TEMPERATURE PROFILE DATA Continued 8-in. (203mm) Glass Refractor and Guard (Type V5G and V2G) 175W max Class II, Division 1, ; Class II, Division 2, Group G; & Class III, Divisions 1, 2 Max Max * Max * Maximum Max Ambient Ambient Ambient Luminaire Ambient Lamp 40 C 55 C 65 C External 40 C Wattage Temp Temp Temp Surface Temp Temp ( C) 50 T3B T3A T3 160 T3C 70 T3B T3A T3 160 T3C 100 T3 T2D T2D 160 T3C 150 T2B T2A T2A 160 T3C 250 N/A N/A N/A N/A N/A 100 T2B N/A N/A 160 T3C 175 T2B N/A N/A 160 T3C 250 N/A N/A N/A N/A N/A 400 N/A N/A N/A N/A N/A 12-in. (305mm) Glass Refractor and Guard (Type R5G and R2G) 400W max Class II, Division 1, ; Class II, Division 2, Group G; & Class III, Divisions 1, 2 Max Max * Max * Maximum Max Ambient Ambient Ambient Luminaire Ambient Lamp 40 C 55 C 65 C External 40 C Wattage Temp Temp Temp Surface Temp Temp ( C) 50 T3B T3A T3 160 T3C 70 T3B T3A T3 160 T3C 100 T3 T2D T2D 160 T3C 150 T2B T2A T2A 160 T3C 250 T1 N/A N/A 160 T3C 400 T1 N/A N/A 160 T3C 100 T2B N/A N/A 160 T3C 175 T2B N/A N/A 160 T3C 250 T2A N/A N/A 160 T3C 400 T2A N/A N/A 160 T3C ALGLAS finished Enclosed Reflector and Guard (Type EG) 400 Watt Max Class II, Division 1, ; Class II, Division 2, Group G; & Class III, Divisions 1, 2 Max Max * Max * Maximum Max Ambient Ambient Ambient Luminaire Ambient Lamp 40 C 55 C 65 C External 40 C Wattage Temp Temp Temp Surface Temp Temp ( C) 50 T3B T3A T3 160 T3C 70 T3B T3A T3 160 T3C 100 T3 T2D T2D 160 T3C 150 T2B T2B T2A 160 T3C 250 T1 N/A N/A 160 T3C 400 T1 N/A N/A 160 T3C 100 T2B N/A N/A 160 T3C 175 T2B N/A N/A 160 T3C 250 T2A N/A N/A 160 T3C 400 T2 N/A N/A 160 T3C * Standard max Ambient Temp is 40 C for 55 C or 65 C, contact factory. N/A = Not Applicable Page-4

FILTR GARD H2 AND H2U TEMPERATURE PROFILE DATA Continued S Acrylic or Polycarbonate 12-inch (305mm) Refractor Type V (A5G, L5G) and Type II (A2G, L2G) S Acrylic or Polycarbonate 12-inch (305mm) Refractor Type V(A5G, L5G) and Type II (A2G, L2G), Class II, Division 2, Group G GROUPS A, B, C, D GROUP G Max Luminaire Max Amb Lamp External Surface 40 C Wattage Max Amb 40 C Temp Temp C Temp 50 T2C 120 T4A 70 T2C 120 T4A 100 T2C 120 T4A 150 T2C N/A N/A LIMITATIONS Under the appropriate conditions, H2 and H2U luminaires may be used in a location as follows: H2 and H2U Filtr Gard luminaires are suitable for use when, under normal conditions, the maximum lamp temperature does not exceed the ignition temperature of S Acrylic or Polycarbonate 12-inch (305mm) Refractor Type V (A5G, L5G) and Type II (A2G, L2G) Non-Hazardous Areas UL1598 Suitable for Wet Locations PARAMETERS FOR USE In non-classified areas these refractors may be used with high intensity discharge (HID) lamps up to 150 watts maximum. WARNING Do not use GE Multi-Vapor II MXR175 lamps in explosion proof or hazardous duty fixtures because they have higher bulb temperatures than standard 175-watt metal halide lamps and may exceed the temperature rating of these fixture types. the gas or vapor present. H2 and H2U luminaires are UL Listed for and comply with NEC Article 501-9(b)(2) as tested and found incapable of igniting the gas or vapor if the ignition temperature is not exceeded. OPTION AUTOMATICALLY SWITCHED QUARTZ* Available for Class II, Division 1 and 2 and Class III Only S S 8-inch (203mm) glass refractor 12-inch (305mm) glass refactor and (V5G and V2G) guard (R5G and R2G) All mountings except low profile Class II, Division 1, Class II, Division 2, Group G Class III GROUPS E, F, G All mountings except low profile Class II, Division 1, Class II, Division 2, Group G Class III GROUPS E, F, G Max Maximum Luminaire Max Maximum Luminaire Lamp Amb External Surface Temp Amb External Surface Temp Wattage C Temperature in C C Temperature in C 50 40 160 T3C 40 160 T3C 70 40 160 T3C 40 160 T3C 100 40 160 T3C 40 160 T3C 150 N/A N/A N/A 40 165 T3B 250 N/A N/A N/A 40 165 T3B 400 N/A N/A N/A 40 165 T3B 175 N/A N/A N/A 40 165 T3B 250 N/A N/A N/A 40 165 T3B 400 N/A N/A N/A 40 165 T3B *LIMITATIONS AUTOMATICALLY SWITCHED QUARTZ 1. 40 C Maximum Ambient 2. Cannot use low profile mounting 3. 150 watt maximum quartz with HID wattage 50 250 4. 250 watt maximum quartz with HID wattage 400 5. With automatically switched quartz, some ballast types are not available depending on voltages, wattages and lamp type. We will use the ballast type available. If a certain type of ballast is requested by the customer, check the factory as we may not have that type available for automatically switched quartz. Non-Hazardous Areas UL1598 Listed Suitable for Wet Locations S Small Globe with Guard H2000-GG Large Globe with Guard H2000-FG Small Refractor with Guard H2000-V5G, H2000-V2G Large Refractor with Guard H2000-R5G, H2000-R2G Industrial Reflector with Guard H2000-EG All mountings except low profile PARAMETERS FOR USE 1. Small Globe with Guard H2000-GG can be used up to 175 watts HID 2. Large Globe with Guard H2000-FG can be used up to 250 watts HID 3. Small Refractors (8-inch)(203mm) with Guard H2000-V5G and H2000-V2G can be used up to 175 watts HID 4. Large Refractor (12-inch)(305mm) with Guard H2000-R5G and H2000-R2G, and Industrial Reflector with Guard H2000-EG can be used up to 400 watts HID N/A = Not Applicable Page-5

MINI GARD TEMPERATURE PROFILE DATA Small Globe and Guard (Type GG) (with or without Standard Dome, Angle Dome or Deep Dome Reflector) (Tested Lamp Envelope Class II, Division 1, ; Surface Temperature) Class II, Division 2, Group G; and Class III Groups E, F Group G Max Max Max Maximum Max Maximum Max Max Ambient Ambient Ambient Luminaire Ambient Luminaire Ambient Ambient Lamp 40 C 55 C 65 C External 40 C External 40 C 40 C Wattage Temp Temp Temp Surface Temp Surface Temp Temp Temp ( C) Temp ( C) 50 T2C T2C T2C 165 T3B 165 T3B T2 70 T2C T2C T2C 165 T3B 165 T3B T2 100 T2A T2A T2A 165 T3B 165 T3B T2 150 T1 T1 N/A 200 T3 N/A N/A T1 METAL HALIDE 70 T2B T2B T2B 160 T3C 160 T3C 100 T2B T2B N/A 160 T3C 160 T3C SIMULTANEOUS PRESENCE (Tested Lamp Envelope Surface Temperature) T2A T2A Class II, Division 1 or Class II, Division 2 Groups Groups E,F 8-in. (203mm) Glass Refractor and Guard (Type V5G and V2G) (Tested Lamp Envelope Class II, Division 1, Surface Temperature) ; Class II, Division 2, Group G; & Class III, Divisions 1, 2 Max Max Max Maximum Max Ambient Ambient Ambient Luminaire Ambient Lamp 40 C 55 C 65 C External 40 C Wattage Temp Temp Temp Surface Temp Temp ( C) 50 T2D T2D T2C 135 T4 70 T2D T2D T2C 135 T4 100 T2A T2A T2A 135 T4 150 T2 T2 N/A 135 T4 METAL HALIDE 70 T2C T2C T2C 160 T3C 100 T2B T2B N/A 160 T3C SIMULTANEOUS PRESENCE (Tested Lamp Envelope Surface Temperature) Max Ambient 40 C Temp T2 T2 T2 T1 T2A T2A Class II, Division 1 or Class II, Division 2 Groups N/A = Not available LIMITATIONS Under the appropriate conditions, MGH and MGHU Mini Gard luminaires may be used in a location as follows: Mini Gard luminaires are suitable for use when, under normal conditions, the maximum lamp temperature does not exceed the ignition temperature of the gas or vapor present. Mini Gard luminaires are UL Listed for and comply with NEC Article 501-9(b) (2) as tested and found incapable of igniting the gas or vapor if the ignition temperature is not exceeded. WARNING Do not use GE Multi-Vapor II MXR175 lamps in explosion proof or hazardous duty fixtures because they have higher bulb temperatures than standard 175-watt metal halide lamps and may exceed the temperature rating of these fixture types. Page-6

MINI GARD TEMPERATURE PROFILE DATA Continued OPTION AUTOMATICALLY SWITCHED QUARTZ* Available for Class II, Division 1 and 2 and Class III Only S 8-inch (203mm) glass refractor (V5G and V2G) All mountings Class II, Division 1, Class II, Division 2, Group G Class III GROUPS E, F, G Max Maximum Luminaire Lamp Amb External Surface Temp Wattage C Temperature in C 50 40 160 T3C 70 40 160 T3C 100 40 160 T3C 150 40 160 T3C * LIMITATIONS AUTOMATICALLY SWITCHED QUARTZ 1. 40 C Maximum Ambient 2. With automatically switched quartz, some ballast types are not available depending on voltages, wattages and lamp type. We will use the ballast type available. If a certain type of ballast is requested by the customer, check the factory as we may not have that type available for automatically switched quartz. (Use one 100 watt single-ended DC [Double Contact] bayonet base lamp.) MINI GARD FLUORESCENT TEMPERATURE PROFILE DATA S Large globe and guard (type FG) with or without standard dome, angle dome, or deep dome. All mounting arrangements, Groups A,B,C,D Class II, Divisions 1 and 2, (Tested Lamp Envelope Surface Temp) GROUPS A,B,C,D GROUPS E,F,G, Groups A,B,C,D (Tested Lamp Envelope Surface Temp) Maximum Maximum Luminaire Maximum Lamp Ambient 40 C External Surface Ambient 40 C Maximum Ambient 40 C Wattage Temperature Temperature ( C) Temperature Temperature FLUORESCENT 13 T2D 85 T6 T2D 26 T2D 85 T6 T2D 52 T2D 85 T6 T2D SIMULTANEOUS PRESENCE Class II, Divisions 1 and 2, TEMPERATURE CODE IDENTIFICATION IDENTIFICATION NUMBER DEGREES C NUMBER DEGREES C T1 450 T3A 180 MAXIMUM T2 300 T3B 165 TEMPERATURE T2A 280 T3C 160 RANGE T2B 260 T4 135 IDENTIFICATION T2C 230 T4A 120 NUMBER T2D 215 T5 100 T3 200 T6 85 Page-7

, POWERFLOOD AND FOOD-PRO TEMPERATURE PROFILE DATA Low Bay Refractor, 15-inch (381mm) (LB5) Angled Low Bay Refractor, 15-inch (381mm) (ALB5) Globe with/without guard (GN, GG) and/or external reflector (DR5, AR5); Low Bay refractor, 15-inch (381mm) (LB5); Low Rigid Conduit, Vertical Suspension Rigid Conduit, Vertical Suspension Bay refractor, 22-inch (559mm) (TA2); Angled Low Bay refractor, 15-inch (381mm) (ALB5) GROUPS A,B,C,D GROUPS A,B,C,D Maximum Maximum Maximum Maximum CONFIGURTIONS Rigid Conduit, Vertical Suspension Lamp Ambient Ambient Lamp Ambient Ambient Wattage 40 o C 55 o C Wattage 40 o C 55 o C UL1598 ; UL1598, Suitable for Wet Locations; UL1598, Lamp Temperature Temperature Temperature Temperature Wattage Outdoor Salt Water 50 T2C N/A 50 T2C N/A 50 150 Watts Maximum 70 T2C N/A 70 T2C N/A 70 150 Watts Maximum 100 T2C N/A 100 T2C N/A 100 150 Watts Maximum 150 T2C N/A 150 T2C N/A 150 150 Watts Maximum Small Globe (GN) NOTE: Temperature ratings the same for globe with/without guard and/or external reflector Rigid Conduit, Vertical Suspension CONFIGURTIONS GROUPS A,B,C,D Maximum Maximum Lamp Ambient Ambient Wattage 40 o C Temperature 55 o C Temperature 50 T3A N/A 70 T3 N/A 100 T2C N/A 150 T2A N/A Low Bay Refractor, 22-inch (559mm) (TA2) Rigid Conduit, Vertical Suspension GROUPS A,B,C,D Maximum Maximum Lamp Ambient Ambient Wattage 40 o C Temperature 55 o C Temperature 50 T2C N/A 70 T2C N/A 100 T2C N/A 150 T2C N/A P-154 POWERFLOOD FLOODLIGHT (For Hazardous Locations) Lamp Wattage Optical assembly with heat and shock resistant tempered glass Ambient 25 o C Lamp Temp C 70 276 T2A 100 276 T2A 150 276 T2A 200 329 T1 250 329 T1 400 450 T1 FOOD-PRO II Enclosed Acrylic or Enclosed Polycarbonate All mountings Class II, Division 2, Groups F, G Class III GROUPS F, G Max Maximum Luminaire Lamp Amb External Surface Temp Wattage C Temperature in C 400 40 120 T4A PULSE METAL HALIDE 250 40 120 T4A 320 40 120 T4A 400 40 120 T4A Page-8