LOWBAY INDUSTRIAL LIGHTING
|
|
|
- Erin Conley
- 10 years ago
- Views:
Transcription
1 COMBINING QUALITY DESIGN AND ENERGY EFFICIENCY FOR SMALL INDUSTRIAL FACILITIES Basics of Quality Lighting Economics of Energy Effective Lighting General Industrial Workspace Lighting Industrial Cleanrooms LOWBAY INDUSTRIAL LIGHTING Task Lighting for Manufacturing Industrial Laboratories Lighting Fixture Specifications Lighting Controls for Industrial Buildings nowhow LOWBAY INDUSTRIAL LIGHTING INTRODUCTION Activities in industrial workplaces are becoming increasingly complex. During a typical day, workers often shift from written material on desks, to mid range computer screens or digital displays Industrial spaces designed by our firm carefully balance issues of quality lighting, daylight integration, and long-term economy of operation. Gerry Power IALD Lighting Designer at a distance. Lighting and control systems must support all of these activities. Workers perform best when the work environment is carefully planned to meet their needs. Taking full advantage of available daylight is a costeffective way to meet lighting needs and contribute to employee sense of well being. Daylight issues are discussed in the Warehouse Skylighting knowhow publication. This guide gives specific information for energy-effective lighting in small industrial spaces that require medium to high light levels. Lowbay industrial workspaces have medium to low ceiling heights of less than 25 feet, with fixtures suspended up to 3 feet lower. Principles discussed in this guide apply as well to larger facilities with the same criteria. High ceiling industrial spaces requiring moderate light levels such as warehouses, are covered in the Highbay Industrial Lighting knowhow publication. Demanding tasks in industrial spaces require well planned lighting systems and balanced brightness, as shown in this laboratory. The Quality Chart below shows important criteria for various industrial tasks. In the following pages, lighting equipment is compared, control strategies identified and sample layouts are shown weighing economic and quality issues. Photo courtesy of Kling-Lindquist Penny Wise and Pound Foolish If poorly designed lighting distracts a worker for just 1% of the time, the loss in productivity can equal $5 per sq. ft.* * Assumes a worker of moderate salary and benefits occupying under 100 sq. ft. = an annual personnel cost of $500 per sq. ft. QUALITY ISSUES FOR INDUSTRIAL LIGHTING Component Production Assembly Control Panel/ Computers Inspection Machining Precision Crafting Fixture location related to workers Light on walls and ceilings Control of direct and reflected glare Light patterns, uniformity vs. shadows Control of source flicker and strobe effect Daylight integration and control Modeling of objects and faces Color rendering and color temperature Appearance of space and fixtures Very Important Important Somewhat Important * Adapted from the Lighting Design Guide. IESNA Lighting Handbook, 9 th Edition Copyright 2003, Northeast Energy Efficiency Partnerships, Inc. All Rights Reserved. Any use, reproduction, or distribution of knowhow or its contents without the express written consent of NEEP is prohibited. Contact or (781) ext. 10.
2 knowhow lowbay industrial lighting basics of quality lighting INDUSTRIAL QUALITY ISSUES Often the first consideration in providing an electric lighting system is to determine the QUANTITY of light that is necessary for the activity in the space. The illuminance values (footcandles) can be calculated fairly precisely if all space parameters are known. Footcandle levels recommended by the Illuminating Engineering Society of North America (IESNA), for lowbay industrial facilities are listed on page 6. Providing a QUALITY lighted environment is a more complex task. A work place that is comfortable and pleasant will have a significant positive effect on worker productivity. Employees are a company s single largest investment so it pays to provide a good working atmosphere. Following are important QUALITY factors to consider. REFLECTANCE AND CONTRAST Manufacturers of paint and other surface materials, publish reflectance values for their products. Specifying the best possible reflective surfaces not only produces a better appearing space, but also a more efficient system. Light that is reflected, not absorbed by dark colors, is usable light. It is important to maintain the reflectance values and relationship as shown in the illustration below. GLARE CONTROL When brightness ratios exceed maximum recommended values, disturbing or disabling glare can result. To minimize glareproducing conditions, consider the following: Achieve required light levels using more lower wattage fixtures to reduce individual lamp brightness. Locate control panels and computer screens facing away from windows or bright light fixtures. If the location of these elements is fixed, adjust the lighting fixture locations and shade the windows. Face computer screens away from bright light sources and windows. Raise bright fixtures, including T-5 and metal halide, above the workers' usual viewpoint. Lower fixtures with bright lamp sources must be shielded. Direct some light toward the ceiling to balance space brightness ratios and reduce contrast between the ceiling and the fixtures. METRICS FOR QUALITY LIGHTING Look for catalogue published values indicating how comfortable or glare-free the lighting fixtures will be in a given space. Visual Comfort Probability (VCP) is based on U.S. research and applies only to direct lensed fixtures. Unified Glare Rating (UGR), a European method, is more comprehensive. The comfort zone for VCP is 70 and above. A UGR value above 19 is considered unacceptable. For more information on glare control refer to Recommended Practice for Lighting Industrial Facilities, IESNA publication ANSI/IESNA RP Photo courtesy of Kurt Versen Co. FLICKER EFFECT The light output of fluorescent and HID sources varies or flickers in a manner that is noticeable to many people. This effect is reduced with high frequency electronic ballasts as frequency is increased from 60-Hz to above 20,000-Hz. Flicker effect with HID is less apparent with coated lamps. This topic is discussed in the Highbay Industrial knowhow publication, and in detail in the IESNA Lighting Handbook 9 th Edition. LAMP COLOR MATTERS Outdated fluorescent and HID lamps such as cool white and mercury vapor, are inferior in color rendering. All light sources recommended in the lighting layouts on pages 4, 5 and 6 and the Lighting Fixture Schedule on page 7, are high color rendering. If the recommended lamps are used consistently, colors will be seen accurately, an important consideration in many industrial tasks and particularly critical for proper identification of safety colors used in many industries as an indication of danger. 2 Dark colors absorb light and light colors reflect. To achieve comfortable brightness ratios encourage the building owner to select reflectance values for equipment and room surfaces based on the values shown above. Based on Recommended Practice for Lighting Industrial Facilities, ANSI/IESNA RP Paint Color Affects Your Costs If surfaces are painted with highly reflective (light) colors, instead of dark colors, the lighting system will be more efficient. A higher percentage of the light will be effectively reflected back into the room and be usable. Photo courtesy of Holophane
3 ECONOMICS OF SYSTEM CHOICES Least Expensive Not Always Most Cost Effective A easy way to look at the cost of owning and operating a lighting system over time is through a Simple Payback analysis: Simple Payback = Compare the three layouts shown on page 4 Industrial Workplace General Lighting. The costs of owning and operating the different systems over a 10-year period, based on 2000 hours per year, at today s costs are detailed in the blue chart below. While the BASE CASE Layout 1 Type A is the least expensive initial cost, it costs the most to operate over time because of the following reasons: To achieve 50 FC Maintained: Type A (BASE CASE) requires 1.18 watts per sq. ft. Type B is more efficient at 1.04 watts per sq. ft. Type E is BETTER YET at 1.01 watts per sq. ft. Incremental investment Incremental annual cash flow * * Adapted from ANSI/IESNA RP-7-01 To maintain 60% of the initial light level over 10 years: Type A must be group re-lamped 3 times. Type B must be group re-lamped 1.75 times. Type E requires just one relamping because of superior lumen maintenance. (See lamp comparison chart below.) This Simple Analysis is just a start in comparing costs over time. Other important factors will affect potential savings such as the cost of money over time, and the impact of associated systems. For example, reducing lighting loads (heat) will almost always lead to HVAC savings. The costs associated with environmental issues such as hazardous waste disposal of lighting system components may be reduced as the components of newer equipment become more sustainable. NEW LIGHT SOURCES In this guide, standard high intensity discharge (HID) metal halide (MH) is compared to newer pulsestart MH. T-8 fluorescent lamps are compared to MH choices, T-5 high output and long compact fluorescent (CFL also called, BIAX, DULUX or PL-L Long) lamps. Each of these lamp/ballast types are used in the example layouts. Other HID sources such as high pressure sodium or mercury vapor have not been recommended because of inherently poor color rendition. When our office budgets lighting for our client s project, we consider first costs of course, but also the economic impact of long-term operation and maintenance. Glenn Urbana, Architect Layout Installed Change Annual Annual Total Annual Simple & Fixture Cost/ Energy Cost Maintenance Operating Savings Payback Type sq. Cost/sq. ft. Cost/sq. ft. /sq. ft. in Years 1 - A (BASE) $ 0.75 N/A $ 0.25 $ 0.08 $ B $ 0.87 $ 0.12 $ 0.21 $ 0.05 $ 0.26 $ E $ 1.20 $ 0.45 $ 0.20 $ 0.04 $ 0.24 $ Lumens Per Watt Lamp/Ballast Efficacies T8 linear fluorescent T5 linear fluorescent T5 CFL Pulse start metal halide Standard metal halide DAYLIGHT IN THE WORKPLACE Daylight is considered the best colorrendering source because our judgment of color is related to natural light. Daylight also has a positive effect on workers sense of well being. Take care to manage heat gain from sunlight and provide supplemental electric lighting near windows to reduce contrast between the windows and adjacent surfaces. For further information on daylighting in industrial settings, see the Warehouse Skylighting knowhow publication. T12 fluorescent, magnetic ballast Initial lumens Design lumens SOURCE EFFICACY IS NOT THE WHOLE STORY LAMP COMPARISON Rated Rated Initial Lumens % of Initial Design In Input Life Initial 40% of (Design Lumens/ Fixture Lamp Type Watts (Hours) Lumens Watt rated life Lumens) Watt Types Metal Halide Standard ,000 20, ,500 66% 54 A Metal Halide Pulse Start ,000 23, ,600 67% 64 B, G Fluorescent T-8 Standard 32 20,000 2, ,750 95% 92 C, F, J, L Fluorescent T-5 High Output 54 20,000 5, ,740 95% 88 C-1, K Compact Fluorescent (long) 50 14,000 4, ,870 90% 77 E, H Induction Lamp ,000 12, ,600 80% 58 Not used The chart above compares light output stability for lamps shown or discussed in this Guide. Close comparison shows that while Metal Halide initially delivers more lumens per watt, over time, Fluorescent may be a better choice. Consider long life Induction lamps where maintenance is difficult. The Rated Input Watts are for lamps alone. For fixture watts including ballast loss, see Lighting Fixture Schedule, pg. 7. knowhow lowbay industrial lighting 3
4 knowhow lowbay industrial lighting industrial workplace general lighting 18'-0" 18'-0" 15'-0" C or C1 A or B LAYOUT 1 Type A - STANDARD PRACTICE Type B - BETTER 16'-0" D or E 22'-0" LAYOUT 2 Type C and C-1 - BETTER Rationale Type E (illustrated below and in layout 3) is rated BETTER YET because it is superior in comfort and quality. It allows more ceiling brightness than the more enclosed Type D. Multiple lamp fixtures D and E are advantageous because if a lamp fails some light is still available from the remaining lamps. Type A is a single lamp fixture. New Induction Lamp fixtures were analyzed as an important consideration for superior uniformity and lamp life, but not included here because of higher initial cost compared to other fixtures shown. (The cost premium currently would be 175% over Type A because more fixtures are required). TASK LIGHTING MAKES SENSE For detailed or close work, supplemental task lighting, close to the work surface makes sense, to optimize energy use, and to give workers personal control to adjust their lighting to meet specific requirements. Relying on the general ambient lighting system to provide adequate light for demanding tasks will result in higher energy costs and less than comfortable working conditions. LAYOUT 3 Type D - BETTER FIXTURES TYPE Type E - BETTER YET A: 250W Metal Halide Open Metal Reflector B: 250W Pulse-Start Metal Halide Prismatic Reflector C: 4' 2-lamp T-8 Fluorescent Pendant Reflector C-1: 4' 2-lamp T-5 Fluorescent Pendant Reflector D: 9-lamp 36W Compact Fluorescent Open Reflector E: 6-lamp 50W Compact Fluorescent Radiating Reflectors 4 Task lighting is good for business, effective energy use and better worker control.
5 6'-0" 10'-0" nominal 8'-0" G Photo courtesy of IBM Corp. F 9'-0" INDUSTRIAL CLEANROOMS Specialized industrial processing areas must meet federal standards for air quality, as well as the need to protect electronics or biological research materials. Luminaires are fully recessed and gasketed so as not to interfere with the flow of clean air in the room. High light levels and good color rendering are essential. Furnishings are often fully moveable so general illumination must be uniform through out the space. POWER LIMITS FOR INDUSTRIAL SPACES* Watts/ Whole Building Method Sq. Ft. Manufacturing Facility 2.2 Workshop 1.7 LAYOUT 4 2'x4' ceiling grid Type F STANDARD PRACTICE H 6'-0" 8'-0" LAYOUT 5 Type G BETTER FIXTURES TYPE 2'x4' ceiling grid F: T-8 Recessed Lensed 2x4 G: Metal Halide Recessed Lensed 1x1 H: Compact Fluorescent 2x2 Watts/ Space Method Sq. Ft. General Lighting Lowbay 2.1 Critical/Detailed Tasks 6.2 Active Storage/Fine Material 1.6 Transition/Corridors 0.7 Equipment Room 0.8 Workshop 2.5 Laboratory 1.8 Control Room 0.5 * From ANSI/ASHRAE/IESNA Standard LAYOUT 6 2'x2' ceiling grid Type H BETTER YET Rationale Layout 6, using 40 watt long CFL is rated BETTER YET for superior color and lumen maintenance compared to Layout 5, Metal Halide. It is also more cost effective than the BASE CASE, Layout 4 - T8 fluorescent. COMPARISON CHART: General Work - 50 FC required Clean Work - 80 FC Required Layout 1 Layout 2 Layout 3 Layout 4 Layout 5 Layout 6 Fixtures Type A Type B Type C Type C-1 Type D Type E Type F Type G Type H Uniformity Comfort & Quality Maintained footcandles Power Density (watts/sq ft)* First Cost Increase Base Base (materials & labor) Case 16% 64% 85% 79% 60% Case -25% -15% OVERALL VALUE Comparisons are based on research of current lighting practice in the New England and New York regions, and illustrated in Layout 1 based on 250W standard Metal Halide open reflector fixtures and in Layout 4 on recessed T-8 fluorescent fixtures. * All lamp/ballast input values from The Advanced Lighting Guidelines Chap. 6 or "Default Wattage Tables" by Lighting Design Lab, Northwest Energy Efficiency Alliance. knowhow lowbay industrial lighting 5
6 knowhow lowbay industrial lighting industrial laboratories Industrial laboratories may include many different tasks from critical research to routine preparation. High incidence of reflective materials such as glass and metal containers, instruments and computer screens make the need for glare free lighting crucial. Work may include hazardous material and must be well-lighted. Adapted from Industrial Lighting Application Guide by Philips J K When we design industrial laboratories, glarefree uniform lighting and sustainability are equal priorities. Mark Loeffler, IALD, LC The Retek Group L K1 L1 10'-0" 2'x4' ceiling grid 10'-0" 10'-0" LAYOUT 7 Recessed Direct Type J STANDARD PRACTICE LAYOUT 8 Pendant Indirect Type K BETTER When using pendant fixtures in continuous runs, 8 ft. modules are cost effective. In layouts 8 and 9, (8) 8 ft. fixtures are used with (2) 4 ft. fixtures to complete the lengths needed for these examples. See Lighting Fixture Schedule, page 7 opposite for Fixture descriptions and pictures. RECOMMENDED QUANTITY OF LIGHT FOR INDUSTRIAL SPACES (FOOTCANDLES) Task Complexity Task Complexity Material Processing Medium: 30 FC Fine: 50 FC Component Assembly Medium: 50 FC Fine: 100 FC Cleanroom Medium: FC Difficult: FC Laboratories General: FC Color Matching: 100 FC Control Panel/VDT Observation: 30 FC vertical From The IESNA Lighting Handbook, 9 th Edition. COMPARISON CHART: Industrial Laboratories - 60FC required Layout 7 Layout 8 Layout 9 Type J Type K Type L Uniformity Comfort & Quality Maintained Horizontal Footcandles Power Density (watts per sq. ft.)* Ceiling Height Range First Cost Increase (material & labor) Base 72% 141% OVERALL VALUE Comparisons are based on research of current lighting practice in the New England and New York regions, and illustrated in Layout 7 based on recessed T-8 fluorescent. * All lamp/ballast input values from The Advanced Lighting Guidelines Chap. 6 or "Default Wattage Tables" by Lighting Design Lab, Northwest Energy Efficiency Alliance. Photo courtesy of The Retek Group LAYOUT 9 Pendant Direct/Indirect Type L BETTER YET Direct/indirect fluorescent lighting provides a comfortable and energy effective atmosphere for most laboratories. This type of system minimizes reflected glare and gives some direct lighting for modeling of objects that the lab worker is studying. 6
7 lighting fixture schedule INDUSTRIAL LIGHTING FIXTURES These specifications include fixtures that ensure a balance of performance, effective energy use and easy maintenance at a costeffective price. Luminaire Efficacy Rating (LER) has been established for common fixtures of this type. Look for catalog information that meets or exceeds the minimum LER values listed here, to assure lighting quality using energy effective equipment. High Intensity Discharge Fixtures are often categorized as High Bay or Low Bay. In this Guide, Low Bay fixtures are shown, designed to provide a wide spread of light for lower ceiling conditions. The spread is typically 65 to 100 degrees, generally greater than a 1.0 spacing to mounting height ratio. Linear Fluorescent Fixtures are designed to minimize accumulation of dirt by providing for convection. Because of required airflow, lenses or diffusers are uncommon. In work environments where greater protection from airborne particles is needed, dust-tight covers are used. In damp locations, diffusers with vapor-tight gasketing are necessary. In lower ceiling heights, T-5 lamped fixtures should be shielded because of potential glare from high brightness. Compact Fluorescent Fixtures have recently been developed using multiple large compact fluorescent lamps. They are similar to HID Fixtures in size and have the advantage of tailored light output because of choices of lamp output and quantity. Induction Lamp Fixtures use a new high frequency electronics driven phosphor-based light source. At more than 60,000 hours life, this source is a good consideration where lamp maintenance is difficult. Available in 55, 85 and 165 watts, it is a viable alternative to HID industrial lighting due to long life and superior lumen maintenance. A. Metal Halide, Lowbay Open Reflector LAMP: (1) 250W Metal Halide Fixture watts: 295 DESCRIPTION: Pendant mounted open metal reflector housing. Field adjustable light pattern for medium to wide light distribution for various ceiling heights. (highbay to lowbay) LER - 50 B. Metal Halide, Prismatic Glass Reflector LAMP: (1) Pulse-start 250W Metal Halide Fixture watts: 288 DESCRIPTION: Pendant mounted open prismatic glass refractor housing with approximately 25% +/- uplight component. Field adjustable light pattern for medium to wide light distribution for various ceiling heights. B (highbay to lowbay) LER - 40 C. T-8 Fluorescent Pendant Industrial Reflector LAMPS: Type C, (2) 32W T8, 835 color Fixture watts: 62 C Type C-1, (2) 28W T5, 835 color Fixture watts: 64 DESCRIPTION: Pendant mounted fluorescent fixture, wired for continuous runs per row. White baked enamel reflector finish. Slotted for 20% uplight. LER - 68 for T8 lamps, T5 lamps not rated. C1 A D. Compact Fluorescent Pendant Reflector LAMPS: (9) FT36W/2G11 Fixture watts: 305 D DESCRIPTION: Pendant mounted large compact fluorescent open reflector fixture with direct distribution reflector and center lamp cluster. Available with 4, 5, 6, 8 or 9 lamps. Not rated for LER E. Compact Fluorescent Pendant, Radiating Reflectors LAMPS: (6) 50W Long CFL, 835 color Fixture watts: 318 DESCRIPTION: Pendant mounted large compact fluorescent fixture with radiating reflector components, direct distribution. Available in various lamp configurations from 3 arms 3 lamps to 6 arms 12 lamps. Not rated for LER F. T-8 Recessed Lensed 2 x 4, Cleanroom Fixture LAMPS: (3) 32W T8, 835 color Fixture watts: 93 E DESCRIPTION: Recessed 2 x 4 fluorescent fixture, electronic ballast, hermetically sealed to meet National Sanitation Foundation Listing (NSF). Not rated for LER G. Metal Halide Recessed Lensed 1 x 1, Cleanroom Fixture LAMP: (1) Pulse-start 175W Metal Halide Fixture watts: 208 F DESCRIPTION: Recessed 1 x 1 sealed to meet NSF Listing. Not rated for LER H. Compact Fluorescent 2 x 2, Cleanroom Fixture LAMPS: (3) 40W Long CFL, 835 color Fixture watts: 107 G DESCRIPTION: Recessed 2 x 2 compact fluorescent fixture, sealed to meet NSF Listing. Not rated for LER J. T-8 Fluorescent Recessed Lensed 1 x 4 LAMPS: (2) 32W T-8, 835 color Fixture watts: 62 DESCRIPTION: 1 x 4 recessed lensed fluorescent. LER - 60 K. T-5 Fluorescent Pendant Indirect Fixture LAMPS: 54W T5 HO, 835 color Type K: 8 ft. (2) lamps, Fixture watts: 118 K Type K-1: 4 ft. (1) lamp, Fixture watts: 58 DESCRIPTION: Pendant mounted indirect fluorescent fixture. One lamp in profile. Type K shared 2-lamp ballast. Not rated for LER. L. T-8 Fluorescent Direct/Indirect Pendant LAMPS: 32W T8, 835 color Type L: 8 ft. (4) lamps, Fixture watts: 114 L Type L-1: 4 ft. (2) lamps, Fixture watts: 62 DESCRIPTION: Pendant mounted indirect fluorescent fixture. Two lamps in profile. Type L shared 4 lamp ballast. Not rated for LER. E L1 J K1 knowhow lowbay industrial lighting 7
8 knowhow lowbay industrial lighting lighting controls When an area is not in use, reduced light levels save energy and operating expense. Several ways of applying controls in industrial building are: Occupancy sensors Manual or building system activated timer switches High/low switched ballasts Building time clock or automated control systems Daylight photosensor switching or dimming High/Low switching of fixtures with an occupancy sensor or a manual switch is cost effective in medium use areas. While frequent switching may reduce fluorescent lamp life hours, calendar life will be considerably longer. New Programmed Rapid Start ballasts significantly improve the life of frequently switched lamps. Daylight sensing controls are an effective and comfortable way to optimize energy use in rooms where abundant daylight is available for at least 25% of the time. Design controls for lights in a zone parallel to the windows within an area depth of 2 to 2.5 times the window height. Automatic Shutoff: A timeclock control or computer-activated system can be programmed to assure that non-essential lighting, including task lights, is off during unoccupied hours. Automatic shutoff is a requirement of ANSI/ASHRAE/IESNA Standard CONTROL TIPS Occupancy sensors should not be connected to the lighting in main circulation aisles. Use Dual Technology sensors in manufacturing and clean rooms to avoid false offs. In large rooms with multiple work zones, small separate lighting zones will give the most energy savings because often not all areas are occupied at the same time. Do not locate manual switches in areas with HID lighting unless the fixtures are instant restart. For further information on Control Strategies see Chapter 8, Advanced Lighting Guidelines 2001, by New Buildings Institute, Inc. Lighting A Major Electric Cost A simple way to save significant operational cost is to plan control strategies to turn lights off or down when they are not needed. The percentage of total energy used for industrial lighting varies based on the magnitude of other loads. Lighting energy use is significant and can be effectively optimized through control strategies. COST SAVING THROUGH STRATEGIC CONTROLS Calculating savings for advanced lighting controls will require specific knowledge about the building or space operating schedule. For example, assume an operation schedule of 2000 hours per year, and an electric cost of $.10 per KWH for the Laboratory Layout 9, using Type L on page 6. The cost of lighting per square ft. is: or Office Equipment 4% Water Heating 3% Power density X hours per year X KWH rate 1000 The annual lighting cost for this Laboratory example is $206 (total sq. ft. (946) x $.22). If the lights are turned off due to control use 35% of the time, then the annual savings = $ HVAC EFFECTS Heating and air-conditioning costs are affected by the lighting load. If lighting energy is reduced, the net HVAC effect always adds to the lighting savings. Adding the effects of HVAC savings at a multiplier of 1.15, typical for New York City,* the total savings including HVAC effects is: $72 x 1.15 = $83. Colder climates in the Northeast would use a somewhat lower factor of *adapted from Lighting Controls Patterns for Design EPRI/ESEERCO 1996 Space Heating & Cooling 43% 1.09 X 2000 hr. X $.10 = $.22 per sq. ft. per yr Lighting 18% Machinery & Other 32% Today, lighting controls are entering a new era, where they will be considered not just for saving lighting energy but as a real amenity for the people for whom buildings are built. F. Rubinstein, Staff Scientist LBNL ACKNOWLEDGEMENTS The LIGHTING KNOWHOW series was developed, funded, and sponsored by the following members of the DesignLights Consortium: Efficiency Vermont National Grid: Massachusetts Electric Narragansett Electric Granite State Electric Nantucket Electric Northeast Utilities: The Connecticut Light & Power Company Western Massachusetts Electric Company NSTAR Electric NYSERDA New York State Energy Research and Development Authority United Illuminating Unitil: Fitchburg Gas & Electric Light Company Northeast Energy Efficiency Partnerships, Inc. For more information contact: Content and graphics by Lindsley Consultants Incorporated. Market research and coordination by Xenergy and Atlantic Marketing Research Co., Inc. Additional consultation by Jim Rogers. Graphic design by Outsource. 8 Disclaimer: These guides are provided for information purposes only. Neither the Sponsoring Agents nor any of their employees or sub-contractors makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product or process disclosed in this document, or represents that its use will not infringe any privately owned rights, including, but not limited to, patents, trademarks or copyrights.
OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED
OFFICE GUIDE 1 OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED ROOM CHARACTERISTICS Length: 60' Width: 25' Height: 9' Reflectivity: Ceiling = 80% Walls = 50% Floor = 20% PRODUCT SPECIFICATIONS Photo
General Lighting Recommendations
Design Guidelines for Energy Efficient Lighting Systems Thank you for your interest in energy efficiency! According to the US Department of Energy, 51% of the energy used in commercial buildings is consumed
Guide to new, energy-efficient lighting technologies for your business
Guide to new, energy-efficient lighting technologies for your business Commercial lighting systems are changing rapidly, with new or improved technologies continuously becoming available. Whether you re
AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings
AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings The Advanced Energy Design Guide (AEDG) seeks to achieve 30 percent savings over Standard 90.1-1999. This guide
Sustainable Office Design (SOD) is different than existing programs STEP 1: STEP 2: STEP 3: STEP 4:
A NGuide a t i o n a l for G r i d Applicants a n d E v e r s o uand r c e Lighting Practitioners V4-20150202 Sustainable Office Design (SOD) is different than existing programs The new SOD Lighting Initiative
IPS HIGH-BAY / LOW-BAY LIGHTING
HIGH-BAY / LOW-BAY LIGHTING NEW ALTERNATIVES TO H.I.D. New from SPI LIGHTING, an exciting addition to our family of fluorescent alternatives to traditional HID high-bay and low-bay lighting. The IPS Series
C2D LowBay: All the power, none of the bulk. C2D Advantage
LowBay LowBay: All the power, none of the bulk Combining superior performance and energy-efficiency with a low-profile modern design, the C2D LowBay provides excellent quality of light for enhanced visibility
Lighting (Illumination) in Warehouses
Lighting (Illumination) in Warehouses Importance of Lighting Workers at a warehouse need to spot oncoming vehicles, pedestrians, slippery floors and other hazards in time to prevent injuries and accidents.
LIGHTING and LIGHTING SYSTEMS
LIGHTING and LIGHTING SYSTEMS Introduction Lighting is an important area of opportunity for energy savings, since it is a large fraction of use of electricity in residential and commercial buildings. Lighting
PPL Electric Utilities Energy Efficiency and Conservation Program
Category Measure Qualification Fixtures/Lamps Controls Incentive Amount T-8 Lighting Package Must replace T12. T8 Lamp Fixture $14/fixture (lamp & electronic ballast) High Performance / Replacing T12 $19/fixture
space types - design briefs
space types - design briefs toilets, lockers and shower design brief The NYC Department of Design and Construction (DDC) manages the construction and renovation of NYC s municipal buildings, many of which
The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are:
5.4 Industry indoor Techniques General The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are: Illuminance on the task is
Lighting New Construction Incentive Application for Business Customers
0 22016 Lighting New Construction Incentive Application for Business Customers A Cash Incentive Energy Efficiency Program brought to you by: Instructions for Use: For complete instructions, please refer
Lighting Retrofit Incentive Application for Business Customers
Lighting Retrofit Application for Business Customers 2015 A Cash Energy Efficiency Program brought to you by: Instructions for Use: For complete instructions, please refer to the Terms and Conditions on
Lutron Energy Savings Claims
Lutron Energy Savings Claims Commercial Claims page 2 Residential Claims page 11 Commercial Claims Commercial Claims These are claims currently utilized by Lutron for commercial product marketing. The
Retrofit HID High Bay Fixtures to Long Life High Efficiency LED
Retrofit HID High Bay Fixtures to Long Life High Efficiency LED 2013 DyoCore Call us today for sales and pricing information: Toll Free: 877.849.6668 www.dyocore.com It is no hidden secret that LED bulbs
Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires
Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires Executive Summary There are many excellent reasons to select a Cree lighting system over one based upon induction technology, even though
A Philips Ledalite Chopstick LED Semi-Indirect Luminaire
All application performance results have been calculated using real luminaire photometric test data and OEM published system specifications for Ledalite factory standard components at the time of publication.
Exterior Lighting for Energy Savings, Security, and Safety
PNNL-18173 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Exterior Lighting for Energy Savings, Security, and Safety EE Richman November 2009 PNNL-18173 Exterior Lighting
High Bay Occupancy Sensor Selection Guide
High Bay Occupancy Sensor Selection Guide Make the most of your energy SM 1 2 Schneider Electric offers a vast array of lighting control sensors for HID and Fluorescent High Bay applications. HID High
Open Office Plan. Function and Orientation. Space Characteristics. Material Properties. - 37 - Gregory Wolfe 2004 Senior Thesis Lighting / Electrical
Open Office Plan Function and Orientation The open office plan on the top floor of the Westwood Community church holds 14 cubicles and doubles as the circulation space for the entire top floor. The area
Solid State Lighting Definitions for Functional and Decorative Applications
NEMA Lighting Systems Division & American Lighting Association Joint Document: LSD 51-2009 Solid State Lighting Definitions for Functional and Decorative Applications Prepared by Solid State Lighting Section,
Session 15 Lighting Fundamentals
Session 15 Lighting Fundamentals Illumination Levels - Example Illumination Levels (Cont.) Lighting Sources in the International World Incandescent: -40⁰ C (-40⁰ F) Fluorescent: -20⁰ C (-4⁰ F) minimum
GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work
GE Lighting Albeo LED Luminaire Linear Industrial Low Bay Lighting (ALV1 - Series) imagination at work Product Features The Albeo ALV1-series LED luminaire is an energy-efficient, low maintenance alternative
Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.
Small Commercial Business Energy Audits Recognizing and addressing the special requirements of the small business market segment. Class 4 Class 4: Lighting Fundamentals Basic Lighting Technology Advanced
induction lighting toll free: tel: fax:
Induction Lighting Introducing induction lighting Induction lamps are one of the newest energy-saving lighting technologies developed in recent years. Induction lighting is based on a technology that is
Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications
Highbay and Lowbay LED Luminaires Energy-efficient, low-maintenance lighting for commercial and industrial applications High Performance Highbay and Lowbay LED Luminaires AccuLite Highbay and Lowbay LED
Lighting at Work. A Health and Safety Guideline for Your Workplace. The benefits of proper lighting. Human factors
A Health and Safety Guideline for Your Workplace The benefits of proper lighting Proper workplace lighting is essential to any good business: it allows employees to comfortably see what they re doing,
Prescriptive Program Rebate Application
Prescriptive Program Rebate Application Check the appropriate program box for your rebate. OID Internal Use Only Cooling FSO (Fluid System Optimization) Foodservice Equipment Heating Lighting Motors &
2016 Commercial Efficiency Program
1. I want to replace my fixture and put LED tubes in it. Do I get rebates for both the fixture and the tubes? No. This type of project qualifies for the LED tube rebate only. 2. Can I install any LED product
GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work
GE Lighting Solutions Albeo LED Luminaire Modular High & Low Bay Lighting (ABHX - Series) imagination at work Product Features The award winning Albeo ABHX-series LED Luminaire utilizes innovative heat-sinking
Small Business Lighting
Small Business Lighting Business Customer Information Opportunity ID: For a free lighting assessment, please contact the Small Business Lighting program at 1-877-287-2250. Company name Date submitted Billing
Lighting is and always has been an important factor
Lighting for Schools James R. Benya, PE Benya Lighting Design December 2001 Lighting is and always has been an important factor in designing and operating schools. Until the 1950s, natural light predominated
Lutron Linear Recessed and Video Conference Fixture Solutions
Lutron Linear Recessed and Video Conference Fixture Solutions Lutron Linear Recessed and Video Conference Fixture Solutions What are linear recessed and video conference fixtures? Lutron fixture solutions
Commercial Energy Savings Guide. www.touchstoneenergy.coop
Commercial Energy Savings Guide www.touchstoneenergy.coop NRECA Pocket Savings Guide Pag.indd 1-3 2/7/05 4:19:07 PM Commercial Energy Saving Tips Notes: This guide provides basic hints on ways to reduce
LED Tubular Lamp / Kit Guide
LED Tubular Lamp / Kit Guide LED lighting products have great potential to replace existing fluorescent lighting, reduce energy use and improve lighting quality in many indoor commercial applications.
GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work
GE Lighting Albeo LED Luminaire Modular High & Low Bay Lighting (ABH2 - Series) imagination at work Product Features The award winning Albeo ABH-series LED Luminaire utilizes innovative heat-sinking and
Lutron Linear Recessed and Video Conference Fixture Solutions
Lutron Linear Recessed and Video Conference Fixture Solutions Lutron Linear Recessed and Video Conference Fixture Solutions What are linear recessed and video conference fixtures? Lutron fixture solutions
SYLVANIA METALARC Pulse Start Metal Halide Lamps
SYLVANIA METALARC Pulse Start Metal Halide Lamps Higher Lumen Maintenance+Longer Life METALARCPulseStart Improved Performance on Every Level The advanced arc tube design of SYLVANIA METALARC PULSE START
Business lighting guide
Business lighting guide Table of contents Advantages of energy-efficient lighting... Take Control & Save Business Lighting Program overview... Implementation and lighting audit walk-through... Introduction
HANDY INFORMAL LIGHTING GLOSSARY
HANDY INFORMAL LIGHTING GLOSSARY 2 nd Generation T8s Mid-grade 800 series T8s. Typically these F32T8s have 2950 3000 catalog or photopic lumens. 3 rd Generation T8s Also called Super T8s. High-lumen 800
A1.5 Classroom Standards
A1.5 Classroom Standards Note: The following standards have been developed and adopted by KU's Instructional and Mediated Spaces Committee (IMSAC), which includes representatives from DCM, Instructional
Lighting Requirements
ASHRAE/IESNA Standard 90.1-1999 Lighting Requirements Joseph G. Howley Jr., IESNA GE Lighting Immediate Past Chair of ASHRAE SSPC 90.1 Lighting Subcommittee 1 How to Get the Standard Standard 90.1-2001
5YR. Advanced LED lighting. High performance industrial lighting. 50% energy against traditional fittings Up to 75% energy saving with sensing
High performance industrial lighting 50% energy against traditional fittings Up to 75% energy saving with sensing Zero maintenance, no need to relamp IK10 rated durable construction Advanced LED lighting
Lighting Control in the Office Space
Lighting Control in the Office Space Lutron Electronics Co., Inc. 2008 AIA/CES Program Registration This program is registered with the AIA/CES for continuing professional education. As such, it does not
Equipment Specifications Rebate/Unit Rules
Fluorescent T8 Fixtures with High Efficiency Electronic Ballasts Replacing T12 Fluorescent with Magnetic Ballast -- Rebate per fixture All 4 foot lamps and ballasts must be on Consortium for Energy Efficiency
Technical Report An Analysis on the Use of LED Lighting for Video Conferencing
An Analysis on the Use of Lighting for Video Conferencing Jim Yorgey, PE Frank Neher, Joe Volkert, and Christina Katrinak March 14, 2016 03/2016 Lutron Electronics Co., Inc. I P/N 367-2622 REV A 1) Abstract...
DuroSite TM High Bay Lighting
DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically
Energy-efficient lighting
Energy-efficient lighting For your home 1204 01/14 Puget Sound Energy P.O. Box 97034 Bellevue, WA 98009-9734 pse.com/myrebates In this guide 4 Be in the know when you buy 5 Know your light sources 6 Your
Leaders In Industrial LED Lighting Solutions. CleanLED Highbay/Lowbay. Energy Efficient LED Lighting Solutions For Industry
Leaders In Industrial LED Lighting Solutions CleanLED Highbay/Lowbay Energy Efficient LED Lighting Solutions For Industry Introduction The Safelux Lighting CleanLED Highbay and Lowbay fixtures are high
REVO-LB. REVO LB (Low Bay Industrial Luminaires)
REVO-LB REVO LB (Low Bay Industrial Luminaires) LOW BAY INDUSTRIAL LUMINAIRES The REVO-LB luminaires have been developed as a new series to be used on low ceilings (Low Bay) adding to our successful energy-saving
INDUSTRIAL & SPORTS LIGHTING
SECTION 7 Vapour Proof Fluorescent Range 96-97 Discharge Lowbay Lighting 98 Fluorescent Low & High Bay Luminaires 99-101 Discharge Highbay Luminaires 102 95 IP65 SURFACE FLUORESCENT LUMINAIRES T5 & T8
Metal Halide Pulse Start vs. Probe Start. By Dick Erdmann GE Specification Engineer
Pulse Start vs. Probe Start By Dick Erdmann GE Specification Engineer As we enter this new age of energy awareness, the lighting community has been at the forefront finding more and more ways to conserve
Green Building Handbook for South Africa Chapter: Lighting Luke Osburn CSIR Built Environment
Green Building Handbook for South Africa Chapter: Lighting Luke Osburn CSIR Built Environment Lighting consumes between about 29-35% of the energy used within commercial office space while lighting only
DOSSIER EN 12464-1. 10.80 m 10.30 CONCISE DESCRIPTION OF THE STANDARD. 2nd edition, june 2012
DOSSIER EN 12464-1 10.80 m 10.30 500 500 CONCISE DESCRIPTION OF THE STANDARD 2nd edition, june 2012 500 500 Foreword EN 12464-1 is an application standard for lighting. The original standard was written
Why is lighting in the workplace important?
OSH Brief No. 3c Why is lighting in the workplace important? From the workers perspective, poor lighting at work can lead to eye strain, fatigue, headaches, stress and accidents. On the other hand, too
WHAT S NEW IN THE 2013 CODE?
WHAT S NEW IN THE 2013 CODE? Changes to mandatory Title 24 lighting requirements California's new Building Energy Efficiency Standards take effect in 2014. They improve the energy efficiency of homes by
TITAN TITAN THE HIGH BAY SERIES
THE HIGH BAY SERIES LOUVERSLED DIVISION OF LOUVERS INTERNATIONAL LED Fixture LED Fixture Short Specification: The LouversLED series of LED luminaires was designed and built with high performance, efficiency,
In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).
TEMPERATURE PROFILE DATA In the following Temperature Profile Data Charts, when a column is headed Tested Lamp Envelope Surface Temperature in C @ 40 C Maximum Ambient, the data (in degrees Celsius) was
Luminaire & Controls Selection Guide L A N D L O N G I N C E N T V E S
Luminaire & Controls Selection Guide L O N G I S L A N D I N C E N T I V E S Energy Solutions Your Cooper Lighting is at the forefront in transforming the lighting industry and setting an unmatched standard
LED High Bay FBX. An economical LED high bay Enjoy flexibility and savings along with quality illumination
LED High Bay FBX An economical LED high bay Enjoy flexibility and savings along with quality illumination Enjoy flexibility and savings along with quality illumination The Philips Day-Brite/Philips CFI
A Guide to Energy Efficient and Cost Effective Lighting
A Guide to Energy Efficient and Cost Effective Lighting This guide provides information on how specifiers and designers can improve the quality and cost effectiveness of lighting schemes through the use
Industrial Linergy LED
Eaton s commitment to supplying energy saving innovative products is the driving force behind. follows in the tradition of highly efficient large space luminaires which have the performance and flexibility
LIGHTING IN THE WORKPLACE
LIGHTING IN THE WORKPLACE Too little: eye strain; fatigue; headaches; stress; accidents. Too much: glare headaches; stress. Lower quality lower productivity Increased absenteeism increased ill health SOME
RETROFIT LIGHTING & CONTROLS SOLUTIONS. Automotive Dealerships
RETROFIT LIGHTING & CONTROLS SOLUTIONS Automotive Dealerships The Challenge and the Opportunity There are over 17,000 automotive dealerships in North America and on average, they use up to 18% more energy
Industrial Solutions. Made to order. Imagine lighting as versatile as the industries it serves.
Industrial Solutions Made to order Imagine lighting as versatile as the industries it serves. The GE Advantage Our Industrial Lighting Systems come complete with service and support from GE, every step
morelux QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04
morelux R QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04 Shopping malls Restaurant, F& B outlets Shops, corridors UV Stabilized Polycarbonate/ Arcylic reflector Standard E27 base with suspension chain/
Codes and Standards Enhancement (CASE) Initiative For PY2008: Title 20 Standards Development
Codes and Standards Enhancement (CASE) Initiative For PY2008: Title 20 Standards Development Title: Analysis of Standards Options for High-Intensity Discharge Lighting Fixtures Prepared for: Pat Eilert
Evolve LED Area Light
GE Lighting Evolve LED Area Light Scalable Area Light (EASA) imagination at work Product Features The next evolution of the GE Evolve LED Area Light continues to deliver outstanding features, while adding
Optilux LED Low Bay and High Bay. Optilux CFL Low Bay. Low Bay. High Bay. IP65 High Bay
324 Optilux LED Low Bay and High Bay 327 Optilux CFL Low Bay 330 Low Bay 332 High Bay 333 IP65 High Bay 334 Architectural High Bay and Pendants 336 325 PIR Sensors 338 Pre-Wired T8 Non Corrosive For LED
PAINT BOOTH LIGHTING
PAINT BOOTH LIGHTING PAINT BOOTH LIGHTING Lighting is comprised of many components that need to be considered when selecting the appropriate fixtures and lamps to accomplish a specific task. Selecting
CHAPTER 10: APPLIANCES AND LIGHTING
Chapter 10: Appliances and Lighting 151 CHAPTER 10: APPLIANCES AND LIGHTING According to the U.S. Environmental Protection Agency, appliances and home electronics account for 20% of energy bills in the
Business Energy Rebates Application
Business Energy Rebates Application Business Energy Rebates make it easy and affordable for you to select energy efficient products for your business. and mail-in rebates are available for energy efficient
Electric Sign Energy Certification Service To California Energy Commission Title 24 Technical Requirements and Audit Instructions (ENVS) Header Title
Header Title Subheadline Electric Sign Energy Certification Service To California Energy Commission Title 24 Technical Requirements and Audit Instructions (ENVS) Electric Sign Energy Certification Service
Invue ECM/EMM EPIC MEDIUM 42-150W
DESCRIPTION The EPIC Collection delivers custom luminaire flexibility with the quality and availability expectations of standard specification grade product. Offered in two housing sizes and hundreds of
T5 LongLast. GE Lighting DATA SHEET
GE Lighting T5 LongLast DATA SHEET Linear Fluorescent Lamps T5 LongLast High Efficiency 14W, 21W, 28W, 35W T5 LongLast High Output 24W, 39W, 49W, 54W, 8W Product information T5 LongLast lamps are triphosphor
Video Conference Indirect Wash LED Fixture
Indirect Wash LED Fixture 369771a 1 06.10.13 LutronR s provide a combination of horizontal and asymmetrical vertical illumination for optimal video conference lighting. The unique reflector design of this
SkyBay LED Low & High Bay 1
SkyBay LED Low & High Bay 1 SkyBay LED Low & High Bay Features: Robust aluminium housing High Performance Nichia SMD LEDs High Lumen output (up to 130lm/W) Low energy usage Mercury Free Long life time,
Evolve LED Garage Light
GE Lighting Evolve LED Garage Light (EG2R) imagination at work Product Features High quality lighting meets long life and controllability with the Evolve LED Garage Light, EG2R. This fixture features an
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY Benson Kwong, CVS, PE, CEM, LEED AP, CCE envergie consulting, LLC Biography Benson Kwong is an independent consultant providing
Commercial LED Lighting Equipment
2010 REBATE APPLICATION Commercial LED Lighting Equipment WHAT S NEW Rebates for outdoor pole/ arm-mounted parking and roadway fixtures, including decorative fixtures, have increased to. Rebates for parking
Commercial Energy Efficiency Program. Save money, reduce energy use and earn incentives. Save money, reduce energy use and qualify for incentives
Save money, reduce energy use and earn incentives by improving the energy efficiency of your business. Georgia Power s Commercial Energy Efficiency Program makes incorporating energy-efficient improvements
Linear Recessed Center Basket Fixture. Lutron
369494c 1 05.16.13 LutronR s offer superior brightness control and well-balanced light through distribution of direct/indirect soft light. Ideal for lobbies, corridors, and office spaces, they are also
Lutron High Bay Fixture Solutions
Lutron High Bay Fixture Solutions Lutron High Bay Fixture Solutions Why high bay fixtures? Lutron high bay fixtures enhance light quality and provide energy-efficient alternatives to traditional HID fixtures.
Intelligent Light. Everywhere.
Intelligent Light. Everywhere. Lights. Intelligence. Insight. Now you can have intelligent light where you need it, when you need it, and perfectly optimized to maximize efficiency in any environment.
Light Control and Efficacy using Light Guides and Diffusers
Light Control and Efficacy using Light Guides and Diffusers LEDs 2012 Michael Georgalis, LC Marketing Manager, Fusion Optix October 11, 2012 Agenda Introduction What Is Light Control? Improves Application
Energy Efficiency Best Practice Guide Lighting
5 Energy Efficiency Best Practice Guide Contents 1 Introduction 4 2 The business benefits of good lighting 5 2.1 Improved productivity 5 2.2 Improved safety 5 2.3 Improved colour rendering 5 2.4 Improved
Lumination LED Luminaires
GE Lighting Lumination LED Luminaires Downlights RI Series Heightened Performance Now just about any recessed downlight can benefit from advanced GE LED fixtures. New GE Lumination RI Series LED Downlights
Illuminating Info: UV-C For HVAC
Page 1 of 6 Home Illuminating Info: UV-C For HVAC Looking for lifecycle guidance or more extensive info for your stationary appli-cations? An industry IAQ veteran weighs in about the design, installation,
Lighting Management solutions
Lighting Management solutions Best practice guide for office buildings PUTTING A STOP TO ENERGY WASTE INTRODUCTION Table of contents 1 Lighting control Best Practice Guide for Office Buildings 2 Guide
T5 Fluorescent Lamps SYLVANIA PENTRON & PENTRON HO
T5 Fluorescent Lamps SYLVANIA PENTRON & PENTRON HO T5 SEE THE WORLD IN A NEW LIGHT. More Light+Increased Versatility PENTRONHO HIGH OUTPUT One Lamp Replaces Two SYLVANIA PENTRON HO T5 lamps were designed