city of edmonds development information



Similar documents
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

2014 Limited Plan Submittal Checklist

Commercial Kitchen Fire Safety

EXETER TOWNSHIP DRY OR WET CHEMICAL FIRE SUPPRESSION SYSTEMS

KITCHEN HOODS GUIDELINES

General Fire Code Requirements Within Commercial Tenant Spaces

Automatic fire-extinguishing systems for commercial cooking

COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

COMMERCIAL KITCHEN HOOD WORKSHEET / CHECKLIST

Name Of Occupancy Date. Yes No Describe

Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.

TENANT DESIGN MANUAL UPDATED JULY 2015

FIRE CODE INTERPRETATION

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

James R. Quiter, P.E., Senior Vice President Rolf Jensen & Associates, Inc.

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

RFQ # PR Replace Kitchen Equipment in the CGR

Winnipeg Fire Department Fire Prevention Branch

City of Bettendorf Fire Alarm System Requirements

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

OREGON FIRE CODE Interpretations and Technical Advisories

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

9770 CULVER BOULEVARD CULVER CITY, CA Incidental improvements: improvements that do not qualify as minor or

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

City of Oviedo Commercial Shell Building Permit Application Guidelines

Aurora Mall. Aurora (Denver), Colorado

presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13

PLAN SUBMITTAL REQUIREMENTS FOR KITCHEN HOOD AND DUCT EXTINGUISHING SYSTEMS

City of Elk River BASEMENT Office Use Only

Town of Bellingham Fire Department

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

Important Ontario Fire Code Information for Building Owners in the City of Windsor

VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY (518) /

Schedule B to By-law

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU MECHANICAL PLAN REVIEW CHECKLIST

BUILDING SAFETY UNIT

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

Bold items are particular to the City of Euless

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

Fire and Life Safety Requirements for Special Events and Temporary Use of the Facilities at the Kitsap County Fairgrounds.

Schedule B to By-law Part A Fees Payable for Permits

CANTON FIRE DEPARTMENT

Safe Method: Gas Safety in Catering Establishments

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

Arapahoe County Residential Water Heater Installation and Inspection Guide

How To Make A House Safe

Building Permit Application

Carbon Monoxide Detection in Commercial Buildings (

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Minnesota State Department of Public Safety

Applications for building permits will not be reviewed until all of the required information has been submitted.

Inspection Item COMMENTS

Building Code Clarifications - 7. Fire Resistance

2. What building projects are exempted? (permit not required)

Special events and tents Fire and life safety requirements

APPLICATION FOR NEW CONSTRUCTION

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

Does Wall Township require an inspection by the building department on resale of a home?

HOMEOWNER S PERMIT GUIDE

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

The Basics of Commercial Kitchen Exhaust Cleaning

BASE PERMIT FEE x.80 = PLAN CHECK FEE*: $ BASE PERMIT FEE x.10 = MECHANICAL INSPECTION FEE: $ BASE PERMIT FEE x.12 = ENERGY CODE REVIEW FEE: $

Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet

Arizona Health Care Association DISASTER PLANNING AND EMERGENCY MANAGEMENT GUIDE POST INCIDENT DAMAGE ASSESSMENT CHECKLIST

Certification: Building Plans Examiner. Exam ID: B3

City of St. Charles Basement Finish or Remodel

Automatic Fire Sprinkler Submittal Requirements

Development Services Guidelines

GOLDEN FIRE DEPARTMENT FIRE & LIFE SAFETY DIVISION

Commercial Building Permit Application & Submittal Guidelines

CLARK COUNTY DEPARTMENT OF BUILDING COMMERCIAL PLUMBING AND MECHANICAL INSPECTION CHECKLISTS 2006 CODE

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

Development Services City of Lawrence, KS

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage

Maintaining Fire Protection Systems

Fire Alarm Systems Permit Packet. City of Greer Fire Department

Notes. Material 1. Appropriate Flammable Liquids

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

2012 CODES SIGNIFICANT CHANGES 2012 IBC

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

SUBJECT CAN: Temporary Systems, Utilities and Equipment. Effective: 4/09/2013. CODE SECTION 2010 California Building Code (CBC)

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

HVAC Code Requirements

Transcription:

#B17 city of edmonds development information Commercial Kitchen Hood & Hood Fire Suppression System Permit Submittal Requirements PERMIT REQUIRED: CODES: FEES: A Commercial Kitchen Hood Mechanical Permit is required for the new installation or alteration of commercial kitchen hoods (including relocation). The International Mechanical Code (IMC) requires that Type I Hoods be installed over any appliance which generates grease laden vapor or smoke. A fire suppression system must be installed for the protection of the commercial cooking equipment in conjunction with a Type I Hood. A separate Fire Suppression System Permit is also required and all systems must meet UL 300 requirements in accordance with the International Fire Code (IFC). A permit is also required for the installation or relocation of Commercial Type II Hoods where cooking or dishwashing appliances produce heat or steam and do not produce grease or smoke such as steamers, kettles, pasta cookers, and dishwashing machines. International Mechanical Code 2006 Edition International Fire Code 2006 Edition International Fuel Gas Code 2006 Edition NFPA 96 (Current Edition) Commercial Kitchen Hood: Based on size and type of equipment or appliance Fire Suppression System: $240, plus $15 City surcharge fee Gas Piping Permit: Issued separately, based on number of fixtures SUBMITTAL REQUIREMENTS FOR TYPE I OR TYPE II COMMERCIAL KITCHEN HOOD: 1. General Notes Two (2) copies 2. Working Drawings - Three (3) sets 3. Commercial Kitchen Hood Worksheet Two (2) copies SUBMITTAL REQUIREMENTS FOR FIRE SUPPRESSION SYSTEM: 1. General Notes, including specifications for the suppression system Two (2) copies 2. Working Drawings Three (3) sets 3. Cut sheets for sprinklers, heads, nozzles, etc. Two (2) copies Revised 7/07

COMMERCIAL KITCHEN HOOD PERMIT SUBMITTAL REQUIREMENTS 1. PERMIT APPLICATION FORM C 2. GENERAL NOTES a) Property address, floor and/or suite number and name of business. b) Designate the use of building or tenant space (i.e., office, retail, medical, restaurant, etc.) and occupancy groups (i.e., B, A2, etc.). c) Specify type of construction of the building (i.e., wood frame, cmu block, brick, etc.). 3. WORKING DRAWINGS Three (3) complete sets with the following: A. SITE PLAN 1) Location of building(s) within twenty (20) feet of hood exhaust outlet. 2) Dimension distances from proposed exhaust outlet to supply ducts, windows, doors, and property lines. B. ELEVATION VIEW 1) Height of exhaust outlet above adjoining grades, roof lines, parapet or elevator shaft, etc. 2) Location of proposed exhaust hood outlet on exterior of building. C. FLOOR PLAN 1) Outline of hood overhang with equipment below. (specify each piece of equipment, i.e., grill, oven, etc.). 2) Dimension hood overhang. 3) Provide walls construction detail including sheetrock, heat shield, etc. 4) Grease filter location, cleanouts, and minimum clearance to combustibles. D. SECTION VIEW OF SHAFT WALL AND HOOD/EXHAUST SYSTEM 1) Detail shaft wall materials. 2) Detail ductwork enclosure and ductwork construction. 3) Exhaust system details. 4. COMMERCIAL KITCHEN HOOD WORKSHEET Complete and submit three (3) copies of the attached kitchen hood worksheet. Clearly show and coordinate information contained in worksheet on the plans. INSPECTION REQUIREMENTS Inspections for the kitchen hood installation, ductwork, shaft walls, etc. is performed by the City Building Inspector during normal City business hours. All shaft work shall be inspected prior to duct installation. Call (425) 771-0220 extension 1333 a minimum of 24 hours in advance for an inspection. At the discretion of the City Planning Division a site inspection may be required to determine the visual impacts of any mechanical projections, diffusers, return air grills, vents, etc. on the building. Check the permit or job card for all required inspections. Revised 7/07

FIRE SUPPRESSION SYSTEM PERMIT SUBMITTAL REQUIREMENTS All Type I Hoods are required to have a fire suppression system. 1. PERMIT APPLICATION FORM C 2. GENERAL NOTES a) Property address, floor and/or suite number and name of business. b) Designate the use of building or tenant space (i.e., office, retail, medical, etc.) and occupancy group (i.e., B, A3, etc.). c) Specify type of construction of the building (i.e., wood frame, cmu block, brick, etc.). 3. WORKING DRAWINGS Three (3) complete sets with the following: a) Show equipment and outline of hood overhang with equipment below. b) Show location of piping, manual pull and nozzle locations. c) Class K fire extinguishers are required. Extinguishers must be mounted in an accessible location no more than 30 feet from the appliance(s) served. In large kitchens or multiple cooking stations additional Class K fire extinguisher may be required. The total number and location of Class K fire extinguishers shall be determined by the City Fire Marshal during inspection. 4. CUT SHEETS Three (3) copies Provide cut sheets showing nozzles and number used, extinguishing agent and amount, shunt switches, piping, etc. and their UL/FM listings are required. NOTE: Make-up air must shut off and the hood exhaust remain operating when suppression system is activated. INSPECTION REQUIREMENTS Inspections for the fire suppression system are conducted by the City Fire Marshal during normal City business hours. All portions of the system must be under test and be observed by the Fire Marshal unless specifically waived. The fire suppression permit number, business name, address and suite number must be provided in order to schedule an inspection. Call (425) 771-0215 extension 1213 a minimum of 24 hours in advance for an appointment. After Fire Department approval contact the City Building Inspector by calling 425-771-0220 extension 1333 to schedule for a final building inspection. At the discretion of the City Planning Division a site inspection may be required to determine the visual impacts of any mechanical projections, diffusers, return air grills, vents, etc. on the building. Check the permit or job card for all required inspections. NOTE: THE PURPOSE OF THIS HANDOUT IS TO ASSIST THE PUBLIC IN COMPLYING WITH DETAILED PERMIT SUBMITTAL REQUIREMENTS. IT IS NOT A COMPLETE LIST OF PERMIT OR CODE REQUIREMENTS AND SHOULD NOT BE USED AS A SUBSTITUTE FOR APPLICABLE LAWS AND REGULATIONS. IT IS THE RESPONSIBILITY OF THE OWNER/DESIGN PROFESSIONAL TO REVIEW THE SUBMITTAL FOR COMPLETENESS AND APPLICABILITY TO OTHER CODES. ONLY COMPLETE APPLICATIONS WILL BE ACCEPTED BY THE CITY FOR REVIEW. Revised 7/07