SECTION 28 05 00 COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY



Similar documents
SECTION ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

C. Conform to requirements of Americans with Disabilities Act (ADA).

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Kaiser Permanente Section

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

UNIFIED FACILITIES GUIDE SPECIFICATIONS

The Pennsylvania State University Physical Security Office. Intrusion Alarm. Performance Specification

Invitation to Bid FIRE ALARM & DETECTION SYSTEM

Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council

TCTC Cabling Specifications

Scope: Communications and Electronic Systems addressed in this section include:

CalMod Design-Build Electrification Services

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION SECURITY SYSTEMS

A. Shop Drawing submittals shall include, but not be limited to, the following:

FIREFINDER XLS ADDRESSABLE FIRE ALARM SYSTEM SECTION 13851

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

Solar Panel Installations

The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs:

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

Security Systems Intrusion Alarm

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

OPEN ITEMS LIST - CONSTRUCTION Project Name: East Central Middle School - Jackson County CLA#: 11003

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

SECTION FIRE ALARM AND DETECTION SYSTEM

H.V.A.C. Design Plumbing Design

TC Grounding and Bonding for Telecommunications Systems

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Specifying an IT Cabling System

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

A. Provide roughing-in, including the empty boxes, conduit, pull strings, etc. under Division 26 for the following related Sections:

SECTION 22 LIGHTNING PROTECTION SYSTEM

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

SECTION TELECOMMUNICATION ROOMS

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

How to Estimate the Cost of a Clean Room and Data Center Equipment Electrical Work. Section 2 Types of Methods of Measurements page 4

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

800 Communications Circuits

A. Provide a complete and fully operation Access Control system fully integrated to the campus Lenel system.

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

E-Version SECTION CHLORINATION SYSTEM PART 1 - GENERAL PART 2 - PRODUCT

Request for Proposals for Photovoltaic System Installation

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

SECTION LOW VOLTAGE LIGHTING CONTROLS

Structured Cabling Statement of Work

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

Fire Alarm Systems Certification

SECTION FIRE ALARM AND DETECTION SYSTEMS

Victor Elementary School District. Technology Infrastructure Standards Victor Elementary School District

CONTRACT DATA SHEET TELEPHONE/DATA INSTALLATION & REPAIR CONTRACT #: CONTRACT DATES: 12/16/14-11/30/15

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Design & Construction Standards, Revised January

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Exhibit C Design Review Guidelines

B. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection.

Specifications for Communication Cabling Distribution Systems

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

ADDENDUM TO THE CONTRACT. for the. Bartlett Regional Hospital Server Room Cooling System Replacement. Contract No. E12-149

SECTION TELECOMMUNICATIONS SYSTEM (Cat 6)

TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011

DEPARTMENTAL REGULATION

ADDENDUM NO. 2 TO PROJECT NO

SECTION 807 PUMP STATION REHABILITATION

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents and Prior Addenda if any, as identified above.

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

4 Installation Requirements

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

SECTION VOICE AND DATA COMMUNICATION CABLING

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES. Level III Content Outline

Sun Vinyl New Construction Windows Homeowner's Warranty

SECTION 611 ACCEPTANCE PROCEDURES FOR TRAFFIC CONTROL SIGNALS AND DEVICES

QUESTIONS & ANSWERS. Re: Invitation for Bid # (West Covina DMV Cabling, Electrical, and Hardware Installation Services)

SECTION OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section

UT Southwestern Medical Center Information Resources Cable Installation Standard

University Design Standard. Fire Alarm Systems

Lenel On-Guard: Security System Installation and Wiring Standards

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Request for Proposal (RFP) IP Cameras/Door Access Control

Transcription:

SECTION 28 05 00 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specifications Sections, apply to this Section. B. Division 26 - Electrical. 1.2 GENERAL REQUIREMENTS A. The Security Contractor shall furnish and install complete system components as described within these Drawings and Specifications to form a complete operating security system. B. The security system(s) will include access control and a closed circuit television (CCTV) subsystem. The access control and CCTV components will be based on the Owner s access control system. Systems will be located as shown on the Drawings, or as otherwise indicated. Card readers, alarm points, cameras, and supporting infrastructure will be located throughout the facilities. C. The Security Contractor shall coordinate with other trades to form a complete system. The Security Contractor is responsible for cabling, system components, devices, cores, miscellaneous conduits, sleeves, junction boxes, and all other peripherals not provided by others to form a complete security system. D. General Contractor shall provide 120VAC, 60 Hz power and conduit where indicated on Drawings. E. The Security Contractor shall provide qualified and skilled workmanship throughout the scope of this project. All installation work shall be of the highest quality using proper installation methods and according to manufacturer's instructions and recommendations. F. The Security Contractor shall strictly adhere to the latest version of all local, national and international codes. G. The Security Contractor is responsible for providing all necessary permits and scheduling all necessary permits and inspections in a timely matter and as directed by the Owner s Project Manager (OPM). H. All work and materials shall conform to the following standards and codes where applicable. Where a conflict occurs, follow the most stringent requirements: RNL Design 28 05 00-1 Metro State College of Denver

1. The National Electrical Code 2. The National Fire Protection Association 3. The Electronics Industries Association 4. The American National Standards Institute 5. The American Society for Testing and Materials 6. Underwriters Laboratories, Incorporated I. It is the Security Contractor's responsibility to protect and maintain all existing base building work and finishes that occur within the area of this scope. J. It is the Security Contractor's responsibility to protect building finishes that the Security Contractor may come in contact with that is not visibly confined to the work area. K. Any questions and/or concerns about the work to be performed shall be addressed prior to the start of that work. Otherwise the Security Contractor shall be the responsible party once that work has started. L. The Security Contractor shall include all necessary labor, tools, equipment, and ancillary materials required to furnish and install a complete and operational security system. M. The Security Contractor is to leave an area in the condition it was found in after completing their work. The Security Contractor shall patch, repaint, clean, adjust, reapply, or refurbish any existing area or surface that is affected as a result of the work 1.3 WARRANTY A. Provide a one-year warranty on all parts, material, equipment, wiring and labor for the complete security system. The warranty period will start the day after Owner's final acceptance. B. System Service 1. The Contractor shall provide emergency repair service for the system at no cost to the Owner, within 24 hours of a request for such service by the Owner during both the installation and warranty periods. This service shall be provided on a 24 hour per day, seven days per week basis. 2. The Contractor shall provide normal service for the system at no cost to the Owner within one business day after receipt of the call. C. Maintain an on-site service log. Coordinate with Owner. 1.4 TRAINING A. Provide a total of 8 hours of on-site training for the security system to the Owner s personnel. Training will support the installed systems. Training personnel must be factory trained and authorized to train on the provided systems. Training by nonqualified personnel will not be recognized as part of the training time specified herein. RNL Design 28 05 00-2 Metro State College of Denver

B. Provide one hard copy and one soft copy (documents on diskette) of operator instruction manuals for the entire system. Operator instruction manuals shall be structured to provide an operator training mechanism for new system operators. C. Provide detailed training agenda and schedule to OPM for approval prior to commencement of formal training. Training shall begin at least two weeks prior to system startup. Security Contractor shall coordinate with Owner and OPM to clearly define the training requirements for all staff. 1.5 REFERENCES, REGULATIONS AND CODE COMPLIANCE A. All workmanship and materials shall conform to and be installed, inspected and tested in accordance with the governing rules and regulations of federal, state and local governmental agencies. 1.6 DEFINITIONS A. Hard-wired system: alarm, supervisory and detection devices are directly connected, through individual dedicated conductors, to distributed control panels. B. Remote Intelligent Controllers (RIC): control panel connect via CAT6 to an Ethernet network using standard TCP/IP protocols providing connection to access control devices through an RS485 bus. C. Reader Control Module (RCM). D. Output Control Module (OCM). E. Input Control Module (ICM). F. Elevator Control Module (ECM). G. IFP - Intelligent Field Panel which may include multiple RICs, power supplies and supporting system hardware and devices. 1.7 INTENT OF DRAWINGS A. The drawings are diagrammatic unless detailed dimensions are included. Drawings show close approximate locations of equipment and devices. Exact locations are subject to the approval of Owner and Owner s representative. B. Anything mentioned in the specifications and not shown in the drawings, or shown in the drawings and not mentioned in the specifications, shall be of like effect as if shown and mentioned in both. In case of differences between the specifications and drawings, the stricter provision, as determined by the project coordinator, shall govern. Omissions from the drawings or specifications, or the incorrect description of details of work which are evidently necessary to carry out the intent of the drawings and specifications, shall not relieve the contractor from performing such work. RNL Design 28 05 00-3 Metro State College of Denver

1.8 SUBMITTALS A. Submittals shall include product data literature and adequate descriptive literature, catalog cut sheets, and other data necessary for the Technology Designer and Architect/Engineer to ascertain that the proposed equipment and materials comply with the specification requirements. B. Product data submittals shall consist of technical data sheets, manufacturers specifications, illustrations, standard schedules, performance charts, instructions, brochures, diagrams and test data furnished to illustrate a product, material or system for the work to be performed. Product data literature is required on all items of material and equipment. C. Clearly indicate on each submittal set the items being submitted by marking or highlighting each item to clearly indicate to the reviewer items being submitted. D. Provide submittals in quantities requested by the architect, engineer or general contractor. Provide submittals with bid responses if so requested. E. Prior to assembling or installing the work, shop drawings shall be submitted for review and approval. F. The Security Contractor shall not purchase any materials or equipment for incorporation into the project prior to receipt of reviewed Submittals from the Technology Designer and/or Architect/Engineer. G. Review of product data shall not relieve the Security Contractor from responsibility for deviations from the drawings or specifications, unless the Contractor has, in writing, called attentions to such deviations at the time of submission and secured written approval. H. The Contractor shall develop and submit complete Submittals and do so in a timely manner. By failing to do so, the contractor agrees to be fully responsible for any and all damages, which might be incurred through the failure to do so. I. Samples may be requested; which shall be physical examples, which represent materials, equipment or workmanship and establish standards by which the work will be judged. 1.9 QUALITY ASSURANCE A. All equipment shall equal or exceed the minimum requirements of NEMA, ASME, ANSI and Underwriters Laboratories. B. All material and equipment furnished shall be new, unused, and free from defects. Equipment shall be clean and free of damage and corrosion, and shall be of the best quality obtainable for the purpose intended. C. Where more than one of any specified item of equipment or material is required, such items shall be the product of one manufacturer throughout the facility. RNL Design 28 05 00-4 Metro State College of Denver

D. All materials used shall bear labels attesting to Underwriters Laboratory approval, provided a standard is established for the material in question. E. All materials shall conform strictly to the standards and specifications set forth in this document. Unless otherwise specified, all products furnished shall be designed, built and installed in accordance with the latest and best practice of the electrical and telecommunications industry, and shall conform to the standards of the NEMA, ANSI, TIA/EIA, ICEA, IEEE, NEC and this Specification wherever they apply. 1.10 PERMITS, LICENSES AND INSPECTIONS A. The Security Contractor shall furnish and file with the proper authorities all drawings required by them in connection with this work. The Security Contractor, if required, shall obtain all official permits, licenses and inspections and shall pay all legal and proper fees and charges. B. The Security Contractor shall, at inception of the work, provide the Project Coordinator with copies of all required building and trade permits. C. The Security Contractor shall be responsible for arranging all inspections and for securing all required signatures. Upon completion of the work, properly completed permits shall be returned to the Project Coordinator, if any are required. 1.11 PROTECTION OF MATERIALS AND EQUIPMENT A. Materials and equipment shall be protected from damage during shipment, storage at the site and throughout the construction period. No damaged items shall be installed and immediate steps shall be taken to obtain replacement so as not to interrupt construction schedule. B. Coordinate site storage of materials and equipment with the General Contractor or Owner. C. If required by the General Contractor, provide a lockable container for material and equipment storage. 1.12 SITE SAFETY AND ACCESS A. Determine from General Contractor all job site requirements such as site access, parking and material storage areas. B. All technicians working on the job site must follow all safety rules set by the General Contractor. All technicians must furnish their own safety equipment including, but not limited to, hard hats, safety glasses, proper footwear (confirm if steel toed boots/shoes are required), fall arrest equipment and safety vests. All safety equipment must be in good working order. C. Attend all safety orientations and meetings as required by General Contractor. RNL Design 28 05 00-5 Metro State College of Denver

D. Provide to General Contractor an up to date MSDS binder listing materials planned for use on the job site that require MSDS information. Provide the number of copies requested. PART 2 - PRODUCTS 2.1 General A. All material shall be new and UL listed and free from damage or defects. The Contractor shall furnish all materials as required. The Contractor is responsible for furnishing any appropriate material needed for proper installation of the systems. Refer to the Drawings for further information and requirements. PART 3 - EXECUTION 3.1 EXECUTION AND INSTALLATION A. The Contractor shall install a complete and functional security system as described with these Specifications and Drawings. The systems shall be installed utilizing good wiring and grounding practices according to local, national, and international codes and be acceptable to the Owner, Engineer and OPM. Life safety and fire codes shall be strictly followed where applicable. B. The Contractor shall provide on the job site a factory trained supervisor to direct, assist and advise in the installation of all systems. C. The Security Contractor shall coordinate work and requirements with the OPM, General Contractor(s), Electrical Contractor(s), and other applicable trades to ensure all coordination requirements are met. D. All cable is to be installed above the lay-in ceiling where possible. It is to be installed in conduit when routed in walls or above gypsum board or inaccessible ceilings. Cable shall be installed in conduit in exposed areas, such as the roof, stairwells, maintenance areas, parking garage, etc. E. Route all system cabling in conduit where conduit has been provided by others. Provide insulated bushings in conduit where not placed by others. Provide conduit where required due to building conditions, or inaccessible ceilings. Provide conduit sleeves around cables whenever they pass through a fire rated or full height partition. Provide UL rated fire systems at these points. F. The Contractor is responsible for providing all fire proofing material and conduit sleeves, unless otherwise indicated. The Security Contractor shall seal around all conduit and wiring whenever it passes through a floor or through fire rated partitions. All fireproofing systems shall be UL rated for the application. RNL Design 28 05 00-6 Metro State College of Denver

G. Rated cable shall be furnished and installed in all spaces. All cable installed in underground conduits must be rated for direct burial use. All cable installed in plenum spaces shall be plenum rated. Cable shall meet equipment manufacturer recommendations for type, size and usage. H. All cabling unless otherwise noted is to be concealed above lay-in ceilings in finished areas and in conduit, or wire ways as indicated on the Drawings. The Contractor shall provide "J-hooks" to properly support the cable. Individual cables above the ceiling space shall be independently supported using hangers or J-hooks secured to the building structure. All cable is to maintain a minimum of 12" from the other building equipment or appurtenances. Some cable tray and J-hooks will be provided as part of the Low Voltage cable contractor scope of work. In TRs cabling shall be installed on top of ladder rack where applicable, all cabling shall be neatly bundled (every 12 ) with Velcro tie wraps. I. Do not damage the outside jacket of any cable. Cables shall not be spliced. J. Where backboards are not furnished, provide plywood backboard painted with two coats of white fireproofing paint. Paint color shall match the existing wall color. Provide where system components shall be mounted or cabling needs to be supported. K. The Contractor shall support all cable throughout the system. The cable shall be tiewrapped at a minimum 4'-0" intervals to support the cable neatly. Cables shall be routed in groups of similar types. All cables being pulled shall not exceed the manufacturers recommended pulling tensions or bending radii. Cables shall be supported horizontally above lay-in ceiling on J-hooks. J-hooks shall be installed at 5'- 0" intervals. J-hook rows shall be installed in straight rows above corridors and hallways. Support cable routed vertically (where conduit is not provided) using "d-rings" on 2'-0" intervals. Provide bundling and tie-wrapping to "d-rings". Provide plywood backboard where "d-rings" are required when not furnished by others. All cables shall be routed neat, straight and parallel or perpendicular to the building structure. L. The Security Contractor shall provide proper terminations and connectors for all cabling throughout the systems. Terminal wiring blocks shall be used in all cabinets, backboards and panels. The Security Contractor shall coordinate this with the system manufacturers requirements. The Security Contractor shall install the wiring onto the proper terminals per the system manufacturers wiring diagram furnished with the components and system shop drawings. All terminals shall be labeled and shall be reflected on the "as-built" drawings. M. The Security Contractor shall furnish and install vinyl labels manufactured by Panduit, approved equal or better, installed on plastic holders and adhered to each end of each cable of the system at the components. The labels shall contain to and from information on each cable. The labels are also to be installed wherever they enter a raceway, cable tray or pass through a pull box. The Security Contractor is to provide a wire number for each wire throughout the security systems. This wire number is to be marked on an as-built single line diagram that is furnished by the Security Contractor at the completion of the project. N. Provide labeling for all system components. Labeling shall show component type and number as assigned to the shop drawings. Label all terminal blocks. RNL Design 28 05 00-7 Metro State College of Denver

O. Testing of the systems shall be the sole responsibility of the Security Contractor. The Security Contractor shall fully test all wiring and system components for proper system operation. Testing shall include, but not be limited to; short circuit, open circuit, under voltage, false detection. After the Security Contractor has thoroughly checked out the total system, the Security Contractor shall submit in writing a request for an acceptance test. Include the last punch list with request for acceptance test. It is the Contractor s responsibility at this time to demonstrate the total system to the Owner, Project Engineer, and OPM. P. Refer to the Drawings for further installation notes and requirements. END OF SECTION 28 05 00 RNL Design 28 05 00-8 Metro State College of Denver