Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Similar documents
Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Fast and Automatic Mapping of Disulfide Bonds in a Monoclonal Antibody using SYNAPT G2 HDMS and BiopharmaLynx 1.3

Salman Azimi, 1 Nayan S. Mistry, 2 and Michelle Wood 2. Drug Quality Control Laboratory, Supreme Council of Health, Doha, Qatar 2

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Pesticide Analysis by Mass Spectrometry

Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

[ DISQUE DISPERSIVE SAMPLE PREPARATION EXTRACTION PRODUCTS ] QuEChERS. Simplifed

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

AMD Analysis & Technology AG

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

WATERS QUANTITATIVE ANALYSIS solutions

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

How To Use An Acquity Qda Detector

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

MarkerView Software for Metabolomic and Biomarker Profiling Analysis

Micromass LCT User s Guide

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Conversion of a USP Gas Chromatography Method to Convergence Chromatography: Analysis of Atropa Belladonna

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

XEVO TQ MS PHARMACEUTICAL APPLICATION NOTEBOOK

Waters Core Chromatography Training (2 Days)

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

ApplicationNOTE Introduction

LC-MS/MS for Chromatographers

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

SIMULTANEOUS QUANTITATIVE DETERMINATION OF OPIOID DEPENDENCY TREATMENT DRUGS IN HUMAN URINE USING UPLC/MS/MS

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Guide to achieving reliable quantitative LC-MS measurements

How To Test For Contamination In Large Volume Water

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Analyzing Small Molecules by EI and GC-MS. July 2014

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

MEDICINAL CHEMISTRY APPLICATIONS BOOK

An Improved SPE-LC-MS/MS Method for the Quantification of Bradykinin in Human Plasma Using the ionkey/ms System

Thermo Scientific ExactFinder Software

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Robert Birdsall, Eoin Cosgrave, Henry Shion, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

DEVELOPMENT OF PFCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

MassHunter for Agilent GC/MS & GC/MS/MS

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Analysis of Phthalate Esters in Children's Toys Using GC-MS

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Supplementary Materials and Methods (Metabolomics analysis)

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

Oasis HLB Cartridges and 96-Well Plates

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Overview. Purpose. Methods. Results

Mass Frontier 7.0 Quick Start Guide

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Transcription:

Michael McCullagh, 1 David Eatough, 1 Vincent Hanot, 2 and Séverine Goscinny 2 1 Waters Corporation, Wilmslow, UK 2 Wetenschappelijk Instituut Volksgezondheid Institut Scientifique de Santé Publique, Brussels, Belgium APPLICATION BENEFITS Pesticide protomer formations can be uniquely identified. Identification and use of protomer collision cross section (CCS) values can be integrated into a routine screening workflow to provide a higher degree of specificity. Improve assay method development and reproducibility through enhanced selectivity and control of fragment ion formation. More efficient structural elucidation through mobility spectral cleanup. WATERS SOLUTIONS ACQUITY UPLC I-Class System ACQUITY UPLC BEH C 18 Column SYNAPT G2-S High Definition Mass Spectrometry (HDMS ) MassLynx Software with UNIFI data processing KEY WORDS CCS values, ion mobility, protomers, spectral cleanup, IMS, pesticides INTRODUCTION Current trends indicate that more than 500 pesticides are routinely used under strict regulation on a global basis. With increasing global trade there is a requirement for multi-analyte screening strategies that are capable of efficiently detecting residue violations to protect consumer safety. Different countries have respective regulations concerning licensing and Maximum Residue Limits (MRLs). The benefits of full spectra acquisition and the specificity of accurate mass measurements are well documented. These are used in combination with time tolerances, isotope fits, fragment ions/ratios, and response thresholds to reduce false positive/negative identifications in screening assays. Should a positive screening violation observation take place, confirmation is typically performed using the selective approach of MRM analysis on tandem quadrupole MS platforms. Criteria used for confident compound identification include the determination of the acceptable product ion ratio tolerances and relative intensities of the detected ions. This is expressed as a percentage of the intensity of the most intense (abundant) ion or product ion, which should correspond to those of the calibration standard at comparable concentrations and measured under the same conditions. It is well known that ion ratio performance can vary with instrumentation parameters, as well as be affected by sample concentration and matrix. The SANCO/12571/2013 guidance document describes the method validation and analytical quality control requirements to support the validity of data used for checking compliance with MRLs, enforcement actions, or assessment of consumer exposure to pesticides in the EU. 1 In this application note, we explore the use of ion mobility with high resolution mass spectrometry as an important tool to gain a greater understanding of ion ratio variations. This technique offers some unique advantages to profiling complex matrices. Ion mobility spectrometry (IMS) is a rapid, orthogonal, gas phase separation technique that allows another dimension of separation to be obtained within an UltraPerformance Liquid Chromatography (UPLC ) timeframe. All analyte/matrix compounds can be differentiated based on size, shape, and charge. In addition, using the fastest UPLC compatible ion mobility duty cycle (10.8 ms), both precursor ion and fragment ion information can be acquired consecutively in a single injection. 1

EXPERIMENTAL UPLC conditions System: ACQUITY UPLC I-Class Column: ACQUITY UPLC BEH C 18 2.1 x 100 mm, 1.7 µm Column temp.: 45 C Flow rate: Mobile phase A: Mobile phase B: Gradient: 0.45 ml/min Water (0.1% formic acid) Acetonitrile (0.1% formic acid) Time Flow rate (min) (ml/min) %A %B 0.00 0.45 98.0 2.0 0.25 0.45 98.0 2.0 12.25 0.45 1.0 99.0 13.00 0.45 1.0 99.0 13.01 0.45 98.0 2.0 13.00 0.45 98.0 2.0 17.00 0.45 98.0 2.0 Injection volume: 5 µl MS conditions System Ionization mode: SYNAPT G2-S ESI+ Desolvation temp.: 550 C Mass range: Acquisition rate: Capillary voltage: Cone voltage: 50 to 1200 Da 5 spectra/sec 1 kv Drift gas: N 2 20 V Collision energy ramp: 10 to 45 ev IMS wave velocity range: IMS wave height: IMS gas flow: IMS duty cycle: 650 m/s 40 V 90 ml/min 10.8 ms Lock mass: m/z 556.2766 (Leucine enkephalin) Empirically isobaric pesticide protomers have been identified and characterized using ion mobility. It is now possible to separate protomers (ions differentiated only by their protonation site) to determine their respective collision cross section (CCS) and individual protomer fragmentation dissociation pathways. This provides a unique view of the product ion formation information by facilitating the selection of product ions will result in improved product ion ratio reproducibility. A schematic representation of the Waters SYNAPT G2-S Platform and an illustration of the mechanism of ion mobility are shown in Figure 1. Figure 1. Schematic of SYNAPT G2-S and an illustration of the mechanism of ion mobility. Sample preparation 10 g of homogenized sample was extracted with 60 ml of 20-mM ammonium acetate in methanol using an Ultra-Turrax device. The crude extract was filtered and diluted up to 100 ml with 5 mm-ammonium acetate in water before injection. An organic mandarin sample was used to produce a matrix matched calibration curve and a previous European ring-test FV-13 sample was analyzed (European Commission proficiency tests for pesticide residues in fruits and vegetables. FV-13 Mandarin Homogenate, 2011). 2

RESULTS AND DISCUSSION For the assay, ion mobility experiments were performed on the ACQUITY UPLC I-Class System and the SYNAPT G2-S using a series of standard solutions, spiked matrices, and the previously described proficiency test. Ion mobility has been successfully used to reduce false positives and false negatives in screening methods for pesticide residues in food. Ion mobility is a process which differentiates molecules as they traverse through a gas, and their progress is related to their average rotational collision cross section (CCS). The CCS is determined by very unique molecular properties, and therefore CCS itself is an important distinguishing characteristic of an ion which is related to its chemical structure (mass, size) and three-dimensional conformation (shape). The conformation can be influenced by a number of factors, including the number and location of charges. In Figure 2, indoxacarb has been selected from the identified components. The retention time aligned extracted mass chromatograms for the precursor ion and characteristic fragment ions of indoxacarb (determined to be present in proficiency sample FV-13) are presented. The data illustrated is representative of MRM transition data that would typically be acquired using a tandem MS platform, where the fragments identified at m/z 218 and m/z 203 could be selected as the confirmation MRM transitions of choice. These fragments have been correctly identified based upon fragmentation identification criteria within the UNIFI pesticide library used to perform a targeted screen. Confidence in the correct identification of indoxacarb could be justified, because the retention time, accurate mass, fragment ion, and CCS tolerances were met. One chromatographic peak Two fragments peaks m/z 203.0185 m/z 218.0422 M R M E Q U I V A L E N T Figure 2. Retention time aligned precursor ion and fragment ion extracted mass chromatograms for indoxacarb observed in proficiency sample FV-13. 3

The mobility trace obtained, shown in Figure 3, indicates that indoxacarb is comprised of two mobility separated species, whereas the conventional precursor ion extracted mass chromatogram does not provide this information. From the structure of indoxacarb it can be seen that protonation is possible on more than one site. Multiple sites of protonation have been observed, where two protomers have been mobility resolved. 3,4 The CCS values of 136.49 Å 2 and 147.94 Å 2 that were previously obtained and recorded can now be utilized to identify indoxacarb with the same level of confidence. All mobility species linked to the same target compound and incorporated in the target CCS list will enhance the screening performance of the method in future assays. Two mobility separated species Figure 3. Mobility trace illustrating the observation of two protomers and corresponding CCS measurements of 136.49 Å 2 and 147.94 Å 2, comprising the extracted mass chromatogram for indoxacarb observed in proficiency sample FV-13. Presented in Figure 4 are the fragmentation spectra generated from the mobility separated protomers of indoxacarb. The distinctive fragments of each respective protomer are shown: a red diamond represents one protomer and a blue diamond represents the other, as well as the common fragments of each protomer (yellow circles). It has previously been shown that the ability to observe the protomer formation can be affected by experimental parameters such as flow rate, matrix, cone voltage and capillary voltage, and that these parameters would likely impact the reproducibility of those experiments as well as the fragments and their intensities observed. 5 This in turn could also impact the assays where MRM transition is the method of choice for confirmatory analysis. It illustrates how critical the choice of MRM transition is and it also provides a unique insight into the fragmentation process being observed. The conventional fragmentation spectrum would be comprised of fragments from both protomers. If a protomer s formation fluctuates, so will the expected fragments. Ion mobility with full spectra acquisition offers a route to greater understanding of the data generated as well as the ability to produce more robust assays. 4

Figure 4. Individual retention time and mobility aligned fragmentation spectra for two mobility separated protomers of indoxacarb observed in proficiency sample FV-13. The yellow circles indicate common fragments, and the red/blue diamonds show unique protomer fragments. Using selective techniques such as FAIMS (Field Asymmetric Waveform Ion Mobility Spectrometry), development of robust assays would be a challenge. Because the number of compounds that can be targeted is limited by duty cycle, it would be difficult to optimize the parameters on an unknown ionized species. The data presented here was generated in a non-targeted analysis experiment, which enabled the pesticide protomers to be discovered. In the example shown of the indoxacarb protomers, it was possible to demonstrate that there are common fragments at m/z 190 and m/z 249. A further example of protomer formation in pesticide residue analysis screening is shown in Figure 5. Here, the mobility trace illustrating the observation of two protomers of fenpyroximate with measured CCS values of 147.15 Å 2 and 158.33 Å 2 is presented. The corresponding single component mobility resolved protomer fragmentation spectra are presented in Figure 6. Protomers of fenpyroximate each respectively produce one of the two most abundant fragment ions and once again, if conventional MRM analysis was performed, ion ratio measurement would be affected by protomer formation. 5

Two mobility separated species Figure 5. Mobility trace illustrating the observation of two protomers of fenpyroximate with measured CCS values of 147.15 Å 2 and 158.33 Å 2. Figure 6. Retention time aligned and two mobility resolved protomer fragmentation spectra for fenpyroximate. 6

Within the context of initial ion mobility residue screening studies, a greater understanding of the analytical challenges has been obtained. The benefits of IMS-MS over non selective techniques such as FAIMS, are clearly illustrated in the case of IMS-MS, where ion mobility is acquired for all components regardless of the sample complexity. The benefits of using time-of-flight mass spectrometry for historical data review, are well known. This capability also applies to IMS-MS. The discovery and presentation of multiple sites of protonation occurring during the analysis for pesticide residues can only be possible if ion mobility data is acquired for all of the components in a sample. Further investigations are warranted, based upon these initial observations, to obtain a full understanding of the experimental parameters that cause protomer formation. CONCLUSIONS In addition to retention time, precursor ion, and fragment mass accuracy, CCS values have been used as screening parameters to perform pesticide residue screening. CCS values have been integrated into a routine screening workflow. For the first time using ion mobility, observation, separation, and characterization of the protomers of indoxacarb and fenpyroximate have been shown. Ion mobility has enabled a unique insight into the process of ionization and fragmentation. Using ion mobility, improved selectivity of fragment ions can be determined; hence more robust analytical assays can be developed where ion ratios are required. References 1. Method Validation & Quality Control Procedures for Pesticide Residues Analysis in Food & Feed: Document No. SANCO/12571/2013. 2. S Goscinny et al. 61 st ASMS Conference, June, 2013. Poster: A novel approach to the reduction of false positive and negative identifications in screening of pesticide residues in food analysis. 3. M McCullagh, S Stead, J Williams, W de Keizer and A Bergwerff. Identification of Multiple Sites of Intra-Molecular Protonation and Different Fragmentation Patterns within the Fluoroquinolone Class of Antibiotics in Porcine Muscle Extracts Using Travelling Wave Ion Mobility Mass Spectrometry. Waters Application Note No. 720004720en. (2013). 4. PM Lalli, BA Iglesias, HE Toma, GF de Sa, RJ Daroda, JC Silva Filho, JE Szulejko, K Araki, MN Eberlin. Protomers: formation, separation and characterization via travelling wave ion mobility mass spectrometry. J Mass Spectrom. 47(6):712 9, (2012). 5. A Kaufmann, P Butcher, K Maden, M Widmer, K Giles, and D Uria. Rapid Commun. Mass Spectrom. Are liquid chromatography/electrospray tandem quadrupole fragmentation ratios unequivocal confirmation criteria? (2009) 23: 985 998. SYNAPT HDMS-based assays allow retrospective data review of mass spectrometry and ion mobility data. Data generated in a non-targeted analysis experiment, enabled the pesticide protomers to be discovered. Waters, ACQUITY UPLC, SYNAPT, High Definition Mass Spectrometry, HDMS, MassLynx, UNIFI, UPLC, and The Science of What s Possible are registered trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2014 Waters Corporation. Produced in the U.S.A. June 2014 720005028EN AG-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com