DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM
|
|
- Simon Willis
- 8 years ago
- Views:
Transcription
1 DRUG METABLISM Drug discovery & development solutions FR DRUG METABLISM
2 Fast and efficient metabolite identification is critical in today s drug discovery pipeline. The goal is to achieve rapid structural identification and complete characterization of major and low-level metabolites in a single analysis. AB SCIEX triple quadrupole-linear ion trap mass spectrometers and accurate mass approaches make that goal a reality. Qual & Quant for the answers you need: Get high-sensitivity quantification and new qualitative capabilities on a single platform the AB SCIEX TripleTF 5600 System and MetabolitePilot Software. Fast and efficient low-level metabolite identification: Acquire predictive MRM (pmrm) and multiple precursor ion and/or neutral loss survey scans in a single analysis, including polarity switching, with the AB SCIEX QTRAP 5500 and LightSight Software. From early discovery to late stage development: Get the information you need to take products from the lab to the clinic with integrated workflows.
3 Simple, clear metabolism workflows The AB SCIEX TripleTF 5600 System and MetabolitePilot Software deliver high sensitivity quantification and new qualitative capabilities on a single platform. The AB SCIEX QTRAP 5500 and LightSight Software use predictive MRM (pmrm) and multiple precursor ion and/or neutral loss survey scans in a single analysis, including polarity switching. AB SCIEX TripleTF 5600 System Accurate mass at the speed and sensitivity of a triple quadrupole: Fast MS and MS/MS acquisition speeds compatible with fast chromatography Resolution over 30,000 External mass accuracy ~1ppm 4 orders of Linear Dynamic Range AB SCIEX QTRAP 5500 System A single platform for drug metabolism and bioanalytical quantification workflows: Targeted and non-targeted workflows Increased sensitivity Increased speed Full quantitative capabilities MetabolitePilot Software Accurate mass data processing and interrogation: Generate cleaner, more relevant data with Multiple Mass Defect Filtering. Store and retrieve critical information in Compound Library & Results Database. Quickly process multiple sample sets in batches. Increase confidence in your results with intelligent scoring and easy-to-visualize color-coding. LightSight Software Exploit the full functionality of QTRAP technology and processing strategies for multiple MetID workflows pmrm high sensitivity targeted approach for really low level detection and confirmation PI/NL (+/-ve polarity switching) structure based filtering approach ideal for reactive metabolite screening Multiple Ion Monitoring (MIM) & Q3 single MS strategies for a non-targeted approach Predict formulae with a high level of chemical intelligence. AB SCIEX TripleTF 5600 System MetabolitePilot Software AB SCIEX QTRAP 5500 System Lightsight Software
4 Drug discovery & development pipeline Metabolite identification is central to many of the activities in the discovery and development pipeline. From rapid structural identification during the discovery process to provide an early perspective on the metabolically labile sites, or soft spots of a drug candidate, to a more complete characterization of the metabolic clearance process to maximize safety and efficacy, there s an ever-increasing demand on throughput. The ability to find, identify and confirm metabolites as fast as possible is critical; not only for the major metabolites, but the very low-level metabolites as well. Being able to do this in a single analysis is a highly sought after goal. With improved strategies for metabolite ID from hybrid triple quadrupole-linear ion trap mass spectrometers and an ever increasing use of accurate mass approaches, these different but complementary mass spectrometric techniques have brought the goal to reality. Application snapshots within the drug discovery & development pipeline 1. EARLY DISCVERY Metabolic Stability GSH Detection 2. LATE STAGE DISCVERY In-vivo Metabolite ID Low-level Metabolite ID 3. DEVELPMENT Definitive Identification Integrated Qual/Quant workflows DRUG DISCVERY PRE-CLINICAL CLINICAL TRIALS FDA REVIEW LARGE-SCALE MANUFACTURING PHASE IV 10,000 CMPUNDS 250 CMPUNDS IND SUBMITTED Phase I 20 To 100 volunteers 5 CMPUNDS Phase II 100 to 500 volunteers Phase III 1,000 To 5,000 volunteers NDA SUBMITTED FDA APPRVED DRUG 5 YEARS 1.5 YEARS 6 YEARS 2 YEARS 2 YEARS Average time in stage
5 Early discovery: metabolic stability screening Metabolic stability assessment Take soft-spot analysis to new levels of speed, efficiency and depth of data with the TripleTF 5600 and MetabolitePilot Software. Apply completely generic methodology to acquire high quality quantitative and qualitative data simultaneously for soft-spot analysis. The AB SCIEX TripleTF 5600 System makes it possible, with TF MS and MS/MS scanning at rates suitable for UPLC. Generate quantitative data on the parent compound from the TF MS scan. Metabolic Stability Rat Liver Microsomes t=5 min Automatically acquire MS/MS data on the major metabolites using high-speed IDA logic. Use accurate mass MS/MS for structural elucidation. A Using a generic IDA method and fast chromatography, metabolic stability profiles were obtained in rat liver microsomes at a substrate concentration of 1 μm at t=0. B A wide range of Imipramine phase I metabolites detected at t=5 minutes by TF MS scan. C The MS/MS spectrum of Imipramine obtained automatically in IDA mode. The high mass accuracy and resolution greatly simplify structure elucidation.
6 Early discovery: reactive metabolite detection Detect low-level reactive metabolites in complex samples using glutathione (GSH) detection with the AB SCIEX QTRAP 5500 System and LightSight Software. The formation of undetected reactive metabolite species can potentially cause idiosyncratic adverse drug reactions (IADRs), which can lead to Black Box warnings and withdrawal of drugs from the market. GSH detection is one of the most sensitive ways of detecting low-level, transient reactive metabolites in complex biological samples. H 3 C H H 2 N NH HN H 3 C NH S NH H S H H 2 N HN NH H Neutral Loss m/z 129 Precursor Ion m/z 272 GSH Adduct Screening 2 Survey scans with polarity switching in 1 injection +EPI m/z 632 +EPI m/z CNL of 129 at 20,000 amu/sec Both triggered via ER scan - Prec + ER + EPI + CNL + ER + EPI - Precursor m/z 272 Total cycle time 1.3 sec High sensitivity GSH adduct screening: Fast scanning and polarity switching with the QTRAP 5500 System enable sensitive detection of GSH-trapped reactive metabolites with a combined precursor ion (negative ion mode, 272 m/z) and neutral loss (positive ion mode, m/z 129) in a single injection. The survey scans are specific to the GSH moiety. They do not require knowledge of parent MS/MS fragmentation, or prediction of metabolites. This provides for comprehensive detection of GSH conjugated metabolites whether predicted or not.
7 Late stage discovery: In vivo metabolite identification Identify metabolites of lead drug candidates for structural elucidation using selective detection techniques such as mass defect filtering with the TripleTF 5600 System. For the first time, multiple mass defect filters can be applied in real time to select peaks for MS/MS data acquisition. There is no need to schedule a second injection to obtain MS/MS information. With the TripleTF 5600 you can detect and characterize major metabolites in vivo with a single injection. A A Minor oxidative metabolite (2.59 minutes) of Carbamazepine detected in protein precipitated plasma. Although eluting just before a major metabolite, multiple mass defect filtering enabled acquisition of MS/MS spectra of both metabolites in the presence of strong matrix interferences. B TF MS scan of peak at 2.59 min in above chromatogram. Large endogenous interferences are present in the scan. Real time mass defect filtering ensures successful acquisition of MS/MS data for the ion of interest in the presence of high background. C The accurate mass MS/MS spectrum of the minor oxidative metabolite obtained in IDA mode using real time mass defect filtering. B C
8 Late stage discovery: low-level metabolite ID In vivo detection in complex matrices Detect low levels of metabolites at clinically relevant concentrations in vivo even in matrices such as bile, plasma, urine and fecal extracts using the QTRAP 5500 System. The predictive MRM (pmrm) survey method on the QTRAP 5500 System is the most sensitive and selective single-injection strategy for identifying metabolites in challenging matrices. Low level in vivo metabolite detection in protein precipitated plasma: extracted ion chromatograms of Carbamazepine metabolites from a 4 mg/kg IV administration in rat, detected by pmrm (176 transitions monitored simultaneously) with the QTRAP 5500 System.
9 Development: definitive in vivo metabolite ID Metabolite characterization in lead compounds Acquire accurate mass data for both parent and fragments in lead compounds with the TripleTF 5600 System and MetabolitePilot Software. An advanced collision cell design and collision energy spread function produce rich MS/MS fragmentation in the low mass range for structure elucidation. Rich fragmentation, high resolution and mass accuracy enable definitive metabolite profiling. Hydroxymidazolam in rat liver microsomes. Excellent accuracy and resolution at the low mass range in MS/MS enables unambiguous assignment of elemental composition.
10 Development: integrated qual/quant workflows Metabolite quantification Estimate metabolite concentrations, without a reference standard, using mass extracted ion chromatograms from high-resolution experiments using the TripleTF 5600 System, MetabolitePilot and MultiQuant Software. TripleTF 5600 System, MetabolitePilot and MultiQuant Software meets the challenge by enabling you to compare the response in the extracted ion chromatogram (XIC) of the metabolite to the parent drug, with high resolution, high resolution and mass accuracy at the low mass range, and more selectivity. Thanks to fast scanning, you can perform these studies under UPLC. Quantification of metabolites and cross-species quantitative comparisons have received greater emphasis due to the Metabolites in Safety Testing (MIST) Guidelines. Estimating metabolite concentrations without a reference standard, however, is challenging. TF MS extracted ion chromatograms of H-Midazolam metabolites and the Midazolam parent. All peaks are automatically integrated and labeled with area counts. Corresponding TF MS scans for the metabolite and parent peaks in Figure 6A. High resolution enables relative quantitation in TF MS mode while reducing or eliminating matrix interference.
11 Biotransformation studies Acquire and process mass spectrometric and UV or radiochromatographic data in the same experiment with the QTRAP 5500 System and LightSight Software and without time-consuming manual procedures. All together now: Correlation of UV and MS data of rat liver microsomal metabolites of Bromocriptine. The Processing Workspace of LightSight Software makes the correlation of UV absorbance, pmrm, and EPI-MS/MS data easy and intuitive.
12 You invest in our technology. We invest in your success. As the world leader in mass spectrometry, AB SCIEX solutions are backed by the industry s most extensive service and support organization. With a network of service professionals, experienced compliance specialists, and over 150 PhD application scientists worldwide, we are dedicated to supporting your technical needs and helping you get the most out of your AB SCIEX systems. AB SCIEX service professionals are recognized as the most highly qualified in the industry. They are certified on our instrument platforms through a rigorous 4-step certification program, with re-certification occurring every two years. This award-winning program helps to ensure that you receive the most efficient, highest-quality, and most up-to-date service available for AB SCIEX products and technology. Choose from flexible service plans and a variety of services for the right level of support for your laboratory s needs and budget. ur customer support network is available to provide expert assistance in the use and application of AB SCIEX products through a comprehensive range of services, including application support, technical service, and training. Whether you access our service and support team by phone, , on-site visits, or through our innovative remote monitoring technology, you can be confident that the AB SCIEX organization will be there for you. For more information, visit For Research Use nly. Not for use in diagnostic procedures AB SCIEX. The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners. AB SCIEX is being used under license /11 Headquarters 110 Marsh Road Foster City CA USA Phone International Sales For our office locations please call the division headquarters or refer to our website at
Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2
Technical ote Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2 Alek. Dooley, Carmai Seto, esham Ghobarah, and Elliott B. Jones verview:
More informationMultiQuant Software 2.0 for Targeted Protein / Peptide Quantification
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification Gold Standard for Quantitative Data Processing Because of the sensitivity, selectivity, speed and throughput at which MRM assays can
More informationImproving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification
Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification Overview LightSight Software for Metabolite Identification is a complete environment
More informationAB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs
AB SCIEX TOF/TOF 4800 PLUS SYSTEM Cost effective flexibility for your core needs AB SCIEX TOF/TOF 4800 PLUS SYSTEM It s just what you expect from the industry leader. The AB SCIEX 4800 Plus MALDI TOF/TOF
More informationAccurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances
Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances TripleTOF 5600 + LC/MS/MS System with MasterView Software Adrian M. Taylor AB Sciex Concord, Ontario (Canada) Overview
More informationAPI 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined
API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation
More informationIncreasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays
Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays Scheduled MRM HR Workflow on the TripleTOF Systems Jenny Albanese, Christie Hunter AB SCIEX, USA Targeted quantitative
More informationThe Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring
The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring Delivering up to 2500 MRM Transitions per LC Run Christie Hunter 1, Brigitte Simons 2 1 AB SCIEX,
More informationOverview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System
Investigating the use of the AB SCIEX TripleTOF 4600 LC/MS/MS System for High Throughput Screening of Synthetic Cannabinoids/Metabolites in Human Urine AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS
More informationIn-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates Using the Explore Workflow on the AB SCIEX TripleTOF 5600 System A major challenge in proteomics
More informationMRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics
MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics With Unique QTRAP and TripleTOF 5600 System Technology Targeted peptide quantification is a rapidly growing application
More informationUnique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS
Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS Using PeakView Software with the XIC Manager to Get the Answers
More informationOverview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationA Streamlined Workflow for Untargeted Metabolomics
A Streamlined Workflow for Untargeted Metabolomics Employing XCMS plus, a Simultaneous Data Processing and Metabolite Identification Software Package for Rapid Untargeted Metabolite Screening Baljit K.
More informationCliquid ChemoView 3.0 Software Simple automated analysis, from sample to report
PRODUCT BULLETIN Cliquid ChemoView 3.0 Software for Routine Screening and Quantitation Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report KEY FEATURES Secure user login that
More informationDrug Metabolism GUIDE TO INNOVATION
Drug Metabolism GUIDE TO INNOVATION Drug Metabolism Analysis with Confidence Pharmaceutical and biopharmaceutical companies have leveraged advancements in basic science perhaps more than any other industry.
More informationSERVICE PLANS. More Productivity. Less Worry. SERVICE PLANS
SERVICE PLANS More Productivity. Less Worry. SERVICE PLANS Flexible service plans to help you maximize the value of your technology investment. Let us help you improve your laboratory productivity and
More informationMultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples
MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples Fast and Efficient Data Review, with Automatic Flagging of Outlier Results Adrian M. Taylor and Michael
More informationAnalysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,
More informationSimultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF
Simultaneous qualitative and quantitative analysis using the Agilent 654 Accurate-Mass Q-TOF Technical Overview Authors Pat Perkins Anabel Fandino Lester Taylor Agilent Technologies, Inc. Santa Clara,
More informationHRMS in Clinical Research: from Targeted Quantification to Metabolomics
A sponsored whitepaper. HRMS in Clinical Research: from Targeted Quantification to Metabolomics By: Bertrand Rochat Ph. D., Research Project Leader, Faculté de Biologie et de Médecine of the Centre Hospitalier
More informationInvestigating Biological Variation of Liver Enzymes in Human Hepatocytes
Investigating Biological Variation of Liver Enzymes in Human Hepatocytes MS/MS ALL with SWATH Acquisition on the TripleTOF Systems Xu Wang 1, Hui Zhang 2, Christie Hunter 1 1 AB SCIEX, USA, 2 Pfizer, USA
More informationMetabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants
Metabolomic Profiling of Accurate Mass LC- Data to Identify Unexpected Environmental Pollutants André Schreiber 1, David Cox 1, Nadia Pace 1, Christopher Borton 2 1 AB SCIEX, Concord, ntario, Canada; 2
More informationEKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS
EKSIGENT EKSPERT NANOLC 4 Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Focused ekspertise In 23, Eksigent changed the way scientists looked at nanoscale chromatography with the introduction
More information# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water
Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system
More informationLC-MS/MS for Chromatographers
LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS, with an emphasis on the analysis of drugs in biological matrices LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS,
More informationDMPK: Experimentation & Data
DMPK: Experimentation & Data Interpretation Mingshe Zhu, Mike S. Lee, Naidong Weng, and Mark Hayward Prerequisite: Entry-level scientists with hands on experience in LC/MS as well as advanced students
More informationMaking the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications
Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications Introduction The resolving power of chromatography combined with the sensitivity and selectivity
More informationSimultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs
Liquid Chromatography Mass Spectrometry SSI-LCMS-068 Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs LCMS-8050 Summary By utilizing the LCMS-8050 s ultrafast scan
More informationamazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS
amazon SL Setting New Standards in Performance, Simplicity and Value Innovation with Integrity Ion Trap Best-In-Class Ion Trap Mass Spectrometer for Routine Analysis The amazon SL entry-level system is
More informationBruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS
Bruker ToxScreener TM A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS ToxScreener - Get the Complete Picture Forensic laboratories are frequently required
More informationA High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS
A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS AB SCIEX QTRAP 4500 LC/MS/MS System and Gerstel, Inc. MultiPurpose Sampler
More informationWaters Core Chromatography Training (2 Days)
2015 Page 2 Waters Core Chromatography Training (2 Days) The learning objective of this two day course is to teach the user core chromatography, system and software fundamentals in an outcomes based approach.
More informationThermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs
Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex
More informationEffects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests
Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests AB SCIEX TOF/TOF 5800 System with DynamicExit Algorithm and ProteinPilot Software for Robust Protein
More informationApplication Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method
Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method Introduction During the last decade, the complexity of samples
More informationNUVISAN Pharma Services
NUVISAN Pharma Services CESI MS Now available! 1st CRO in Europe! At the highest levels of quality. LABORATORY SERVICES Equipment update STATE OF THE ART AT NUVISAN CESI MS Now available! 1st CRO in Europe!
More informationWATERS QUANTITATIVE ANALYSIS solutions
More sensitivity. More speed. What more can you ask for in a complete quantitative analysis solution? WATERS QUANTITATIVE ANALYSIS solutions THE CHALLENGE OF QUANTITATIVE ANALYSIS Tandem mass spectrometry,
More informationProteinPilot Report for ProteinPilot Software
ProteinPilot Report for ProteinPilot Software Detailed Analysis of Protein Identification / Quantitation Results Automatically Sean L Seymour, Christie Hunter SCIEX, USA Pow erful mass spectrometers like
More informationRapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit
Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit Fast, simple and cost effective analysis Many areas of biochemical research and
More informationMarkerView Software 1.2.1 for Metabolomic and Biomarker Profiling Analysis
MarkerView Software 1.2.1 for Metabolomic and Biomarker Profiling Analysis Overview MarkerView software is a novel program designed for metabolomics applications and biomarker profiling workflows 1. Using
More informationRapidFire High-throughput MS technology. Enhancing Drug Discovery Turning Mass Specs into Plate Readers
RapidFire High-throughput MS technology Enhancing Drug Discovery Turning Mass Specs into Plate Readers 1 Drug Discovery with RapidFire Target Selection High-throughput Target Screening (HTS) Lead Optimization
More informationWhat Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model?
What Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model? authors M. David Ho 1, Bob Xiong 1, S. Stellar 2, J. Proctor 2, J. Silva 2, H.K. Lim 2, Patrick Bennett 1, and Lily Li 1 Tandem Labs,
More informationAnalyst 1.6.1 Software
MAX cover image size 4.8 inches X 7.8 inches In Body page mode, draw a graphic frame to match this section and then go to the next step. Delete this text from the Front Cover Master page. View>Master Pages,
More informationINTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS
AxION iqt GC/MS/MS INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE IDENTIFY WHAT YOU RE LOOKING FOR (AND EVEN WHAT YOU RE NOT) The GC/MS/MS Solution for the Work You Do The ideal solution for industrial,
More informationBiological importance of metabolites. Safety and efficacy aspects
Biological importance of metabolites Safety and efficacy aspects Bernard Walther Technologie Servier Biological importance of metabolites Safety testing of drug metabolites Bioanalytical strategy Structural
More informationApplication Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software
Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software Abstract Presented here is a case study of a walk-up liquid chromatography
More informationFactors Influencing LC/MS/MS Moving into Clinical and Research Laboratories
Factors Influencing LC/MS/MS Moving into Clinical and Research Laboratories Matthew Clabaugh, Market Development AACC Workshop St. Louis, MO September 17,18 2013 Factors Influencing LCMSMS Moving into
More information泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics
泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics 2014 Training Course Wei-Hung Chang ( 張 瑋 宏 ) ABRC, Academia
More informationMassHunter for Agilent GC/MS & GC/MS/MS
MassHunter for Agilent GC/MS & GC/MS/MS Next Generation Data Analysis Software Presented by : Terry Harper GC/MS Product Specialist 1 Outline of Topics Topic 1: Introduction to MassHunter Topic 2: Data
More informationProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry
ProteinScape Proteomics Data Analysis & Management Innovation with Integrity Mass Spectrometry ProteinScape a Virtual Environment for Successful Proteomics To overcome the growing complexity of proteomics
More informationXEVO TQ MS PHARMACEUTICAL APPLICATION NOTEBOOK
XEV TQ MS PHARMACEUTICAL APPLICATIN NTEBK Xevo TQ MS: Pharmaceutical Applications The Changing Face of LC/MS: From Experts to Users...3 Improving MS/MS Sensitivity using Xevo TQ MS with ScanWave...11 Simultaneous
More informationMaking the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications
TECHNICAL NOTE Toxicology Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications Introduction The resolving power of chromatography combined with
More informationUsing Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract
Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate
More informationGENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1
GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert, Michel Lhermitte, Frederic Grisel Laboratoire de Toxicologie & Génopathologie, CHRU Lille, France Waters Corporation, Guyancourt,
More informationSimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data
SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data Automated Data Interpretation for Glycan Characterization Jenny Albanese 1, Matthias Glueckmann 2 and Christof Lenz 2 1 AB
More informationThermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID
Thermo Scientific Compound Discoverer Software A New Generation of integrated solutions for small molecule structure ID Transforming Small Molecule Research Solutions for Small Molecule Structural ID Thermo
More informationUltra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring
PO-CON1359E Ultra Fast UHPLC-LCMSMS Method Development in HPLC 2013 MASS-09 Anja Grüning 1 ; Brigitte Richrath 1 ; Klaus Bollig 2 ; Sven Vedder 1 ; Robert Ludwig 1 1 Shimadzu Europa GmbH, Duisburg, Germany;
More informationJennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION
A Validated Liquid-Liquid Extraction Method with Direct Injection of Hexane for Clopidogrel in Human Plasma Using UltraPerformance Convergence Chromatography (UPC 2 ) and Xevo TQ-S Jennifer L. Simeone
More informationMass Spectrometry Based Proteomics
Mass Spectrometry Based Proteomics Proteomics Shared Research Oregon Health & Science University Portland, Oregon This document is designed to give a brief overview of Mass Spectrometry Based Proteomics
More informationThermo Scientific ExactFinder Software
mass spectrometry Thermo Scientific ExactFinder Software Workflow software for routine targeted and general unknown screening Unifies qualitative and quantitative high-resolution accurate mass workflows
More informationQuick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System
Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System Olaf Scheibner, Maciej Bromirski, Thermo Fisher Scientific, Bremen, Germany
More informationDetection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS
Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS D. Loeffler 1, M. Ramil 1, T. Ternes 1, M. Suter 2, R. Schönenberger 2, H.-R. Aerni 2, S, König, A. Besa,
More informationAxION edoor. Web-Based, Open-Access Mass Spectrometry Software
AxION edoor Web-Based, Open-Access Mass Spectrometry Software 2 AxION edoor is the open-access software solution for today s fast-paced laboratory. It is designed to operate and optimize the management
More informationPesticide Analysis by Mass Spectrometry
Pesticide Analysis by Mass Spectrometry Purpose: The purpose of this assignment is to introduce concepts of mass spectrometry (MS) as they pertain to the qualitative and quantitative analysis of organochlorine
More informationMS/MS analysis of Polyphenols
Purdue-UAB Botanicals Center for Age-Related Disease MS/MS analysis of Polyphenols Jeevan Prasain Ph.D. Pharmacology & Toxicology UAB Polyphenols H Caffeic acid Phenolic acids and derivatives H EGC (Flavanol)
More informationResearch-grade Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, How I learned to ditch the triple quad and love the QE
Research-grade Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, How I learned to ditch the triple quad and love the QE Jacob D. Jaffe Skyline Webinar July 2015 Proteomics and
More informationis a knowledge based expert decision support tool for predicting the metabolic fate of chemicals in mammals.
is a knowledge based expert decision support tool for predicting the metabolic fate of chemicals in mammals. Reference 08/15 Features and Benefits Summary Efficient Metabolite Structure Elucidation Early
More informationSession 1. Course Presentation: Mass spectrometry-based proteomics for molecular and cellular biologists
Program Overview Session 1. Course Presentation: Mass spectrometry-based proteomics for molecular and cellular biologists Session 2. Principles of Mass Spectrometry Session 3. Mass spectrometry based proteomics
More informationAnalysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection
Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection Evelyn Goh, Antonietta Gledhill Waters Pacific, Singapore, Waters Corporation, Manchester, UK A P P L I C AT
More informationTutorial 9: SWATH data analysis in Skyline
Tutorial 9: SWATH data analysis in Skyline In this tutorial we will learn how to perform targeted post-acquisition analysis for protein identification and quantitation using a data-independent dataset
More informationSimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data
SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data Automated Data Interpretation for Glycan Characterization Jenny Albanese1, Matthias Glueckmann2 and Christof Lenz2 1Applied
More informationPep-Miner: A Novel Technology for Mass Spectrometry-Based Proteomics
Pep-Miner: A Novel Technology for Mass Spectrometry-Based Proteomics Ilan Beer Haifa Research Lab Dec 10, 2002 Pep-Miner s Location in the Life Sciences World The post-genome era - the age of proteome
More informationExtraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis
Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines
More informationAiping Lu. Key Laboratory of System Biology Chinese Academic Society APLV@sibs.ac.cn
Aiping Lu Key Laboratory of System Biology Chinese Academic Society APLV@sibs.ac.cn Proteome and Proteomics PROTEin complement expressed by genome Marc Wilkins Electrophoresis. 1995. 16(7):1090-4. proteomics
More informationLipid analysis by multiple "omic" mass spectrometry platforms Where we ve been, where we are, and where we re going
Lipid analysis by multiple "omic" mass spectrometry platforms Where we ve been, where we are, and where we re going Jeff McDonald Department of Molecular Genetics UT Southwestern Medical Center Dallas,
More informationAgilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES
Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES AGILENT ENHANCED MATRIX REMOVAL LIPID ARE LIPIDS WEIGHING YOUR SAMPLES DOWN? Interference from lipids is a problem for labs measuring
More informationAnalyst 1.6 Software. Software Reference Guide
Analyst 1.6 Software Software Reference Guide Release Date: August 2011 This document is provided to customers who have purchased AB SCIEX equipment to use in the operation of such AB SCIEX equipment.
More informationSPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application
More informationAdvantages of the LTQ Orbitrap for Protein Identification in Complex Digests
Application Note: 386 Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests Rosa Viner, Terry Zhang, Scott Peterman, and Vlad Zabrouskov, Thermo Fisher Scientific, San Jose, CA,
More informationChemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample
More informationBuilding innovative drug discovery alliances. Evotec Munich. Quantitative Proteomics to Support the Discovery & Development of Targeted Drugs
Building innovative drug discovery alliances Evotec Munich Quantitative Proteomics to Support the Discovery & Development of Targeted Drugs Evotec AG, Evotec Munich, June 2013 About Evotec Munich A leader
More informationAnalyst 1.6.1 Software. Advanced User Guide
This document is provided to customers who have purchased AB Sciex equipment to use in the operation of such AB Sciex equipment. This document is copyright protected and any reproduction of this document
More informationDaniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz
Toxichem Krimtech 211;78(Special Issue):324 Online extraction LC-MS n method for the detection of drugs in urine, serum and heparinized plasma Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische
More informationaurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS
aurora ICP-MS The Science of Sensitivity Innovation with Integrity ICP-MS Powers the Business of Quantification aurora ICP-MS enhanced value package Bruker s ICP-MS is famous for its innovative and unique
More informationNew drugs of abuse? A case study on Phenazepam & Methoxetamine
New drugs of abuse? A case study on Phenazepam & Methoxetamine Presenter: Nadia Wong Co authors: Dr Yao Yi Ju & Alex Low Xuan Kai Analytical Toxicology Laboratory Clinical & Forensic Toxicology Unit Applied
More informationA Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples
A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples Mary Lame, Hua Yang, Sherri Naughton, and Erin Chambers Waters Corporation, Milford,
More informationCliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.
Application Note Cliquid Drug Screen & Quant Software A Fast and Sensitive LC/MS/MS Method for the Quantitation and Confirmation of 30 Benzodiazepines and Nonbenzodiazepine Hypnotics in Forensic Urine
More informationUPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research
UPLC-MS/MS Analysis of in Plasma for Clinical Research Dominic Foley and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION BENEFITS Analytical selectivity improves reproducibility through removal
More informationLC-MS/MS Solutions for the Pharmaceutical and CRO Industries TSQ Series -based Solutions for Drug Discovery and Development
m a s s s p e c t r o m e t r y LC-MS/MS Solutions for the Pharmaceutical and CRO Industries TSQ Series -based Solutions for Drug Discovery and Development Part of Thermo Fisher Scientific ACCELERATING
More informationThe Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis
The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis Stephen Lock AB SCIEX Warrington (UK) Overview A rapid, robust, sensitive and specific LC-MS/MS method has been developed for
More informationRapid LC/MS/MS Method Development for Drug Discovery
Rapid LC/MS/MS Method Development for Drug Discovery A three-checkpoint paradigm offers a way to rapidly develop a very reliable bioanalytical method when LC/MS/MS is used in the drug discovery process.
More informationAgilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS
Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS AGILENT 6000 SERIES LC/MS SOLUTIONS UNRIVALED ACHIEVEMENT AT EVERY LEVEL The Agilent 6000 Series of LC/MS instruments
More informationFast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract
More informationQuantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay
PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird
More informationMass Frontier 7.0 Quick Start Guide
Mass Frontier 7.0 Quick Start Guide The topics in this guide briefly step you through key features of the Mass Frontier application. Editing a Structure Working with Spectral Trees Building a Library Predicting
More informationInternational GMP Requirements for Quality Control Laboratories and Recomendations for Implementation
International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation Ludwig Huber, Ph.D. ludwig_huber@labcompliance.com Overview GMP requirements for Quality Control laboratories
More informationCorrelation of the Mass Spectrometric Analysis of Heat-Treated Glutaraldehyde Preparations to Their 235nm / 280 nm UV Absorbance Ratio
an ABC Laboratories white paper Correlation of the Mass Spectrometric Analysis of Heat-Treated Glutaraldehyde Preparations to Their 235nm / 280 nm UV Absorbance Ratio A. Sen, R. Dunphy, L. Rosik Analytical
More informationAgilent LCMS products and the application strategies in veterinary drug analysis
Agilent LCMS products and the application strategies in veterinary drug analysis Experience A New Level of Confidence Ma Xin 马 鑫 LCMS Application Engineer Internal Sales Training - The new 6495 QQQ LC/MS
More informationApplication Note # MT-103 FAST-SRM: A new Single Reaction Monitoring Method for Fast, Targeted Drug Distribution Testing in Tissue Sections
ruker Daltonics pplication Note # MT-103 FST-SRM: new Single Reaction Monitoring Method for Fast, Targeted Drug Distribution Testing in Tissue Sections Targeted analysis of drug molecules and metabolites
More information