Project files. Customer copy Legrand copy



Similar documents
Linkeo 19" freestanding cabinets

Dlp-s & WIRING DEVICES. THE MAXIMUM FReeDOM OF ChOICe. SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Copper Pre-terminated Assemblies

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

Structured Cabling, Earthing & Equipotential Bonding

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Solid as a rock Soliroc

SERVER ROOM CABINET INSTALLATION CONCEPTS

R.C.C.B. s two-pole LEXIC

Screened cable and data cable segregation

Specifying an IT Cabling System

How To Set Up A Minipatch System For A Small Office Or Home Use

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Cabinets 101: Configuring A Network Or Server Cabinet

HARTING Ethernet Cabling 4-poles Overview

Power Separation Guidelines for SYSTIMAX Installations

How To Build A T7 Rack For Information Technology

19 DYNAmax Free Standing Server C A B I N E T s

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

P System Cubicles. Certified for more safety

19 DYNAmax Free Standing Server C A B I N E T s

Powerware Enclosure Solutions Product Focus

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Mureva Assembly surface mounted wiring devices

HEALTHCARE «HOSPITALS, CLINICS AND RETIREMENT HOMES» STRUCTURED CABLING INFRASTRUCTURE

428 MY HOME Structured cabling system for the home sector

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

Copper Cables CONNECTIVITY & CABLING SYSTEM

Batibox TM flush-mounting boxes for dry partitions

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Networking Cabinets and Enclosures

HARTING Ethernet Cabling 4-poles Overview

ROLINE THE Difference

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Standard Buccaneer - Ethernet

Data Centre Solutions

Cabinet V800 V800 CABINETS

Introduction to Data Centre Design

Knürr Smaract. Knürr Smaract. CompactRack

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

19 NETbox SOHO Network Wall Mounting Cabinets FAMILY

DIGITUS Network & Server Cabinets. UNIQUE Series

ATS Overhead Table Shelf System INSTRUCTION MANUAL

TCTC Cabling Specifications

RACK ENCLOSURES & ACCESSORIES

Innovative Connectivity Solution for Maximum Performance and Security

IT&T Infrastructure Standards

Panduit 28 AWG Patch Cords Installation Guideline

Structured Cabling Introduction & Installation Guide

HARTING econ 3000 Introduction and features

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

SSG PRODUCTS FOR SHIPS AND OFFSHORE

ADC Structured Cabling Solutions

Audio, power, and control data

InForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

EN and EN : 2008 Integrated standards for telecommunications cabling installation

NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS)

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

Niko Home Control. Installation Manual

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Copper Cabling Infrastructure Offering

know-how Giant in distributing electricity for industry Prisma GK

Network Design. Yiannos Mylonas

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

The 10G wiring system

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Online Warranty System Training Manual Installation Partner Application Process

19" GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN

Ethernet Cat 5e & Cat 6 Patch Panels

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

Cabinet Overview Frame Material & Construction. Shelves Fan Options Cable Trays Blank Panels Brush Cable Entry

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Component Series Racks Component Series Rack Plus Bundles...3 Component Series stackable skeleton Racks...4

Cat7/Class F New Installation Concept New infrastructure. Handbook

HARTING Ethernet Cabling 8-poles Overview

06 / Optional components. MAXDATA PLATINUM Server-Rack PLATINUM. [Product Guide]

10 Gigabit Ethernet over copper: Unshielded, unprotected?

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

How To Build A Compact Rack By Kn\U00Fcrr

Functional system Prisma P

Data Center Cabling Design Trends

contents my HOmE - STrUCTUrEd CaBLing SYSTEm FOr THE HOmE SECTOr

WORLD. Security Tests. FULL COMPLIANCE From all Quality and SAFE FUNCTIONAL. Delivery from Stock

HERZ-Thermal Actuators

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

BLADE S-MAX Cabinet for Blade Server

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

6000 Series Buccaneer

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Copper Patch Cords. Impact On Network Performance and Reliability

Transcription:

20 years warranties Project files Structured cabling Systems categories 6A, 6 & 5e Customer copy Legrand copy

TO BENEFIT FROM LEGRAND WARRANTIES 1 Complete and sign the Identity document: Worksite details*, Commitment to the 14 key points *, List of VDI products *, List of Additional products *. 2 Print out the documentation of the acceptance test carried out on the: Link* Channel* 3 Make a copy of the existing plan showing the location of the products and bearing your company stamp. 4 Complete and sign the selected 20-year warranty agreement(s): Performance* Category 6* Category 5* Category 6a* (10 Gig) System Components* Category 6* Category 5* Category 6a* (10 Gig) Send all these documents by post to: Legrand Service Relations Pro 128 av. de Lattre de Tassigny 87045 Limoges Cedex - France you will receive confirmation by post that the warranty has been issued for the designated worksite. The Project Owner and the Project Manager will also receive a copy of this confirmation. we will remind you of this Commitment by Legrand during the warranty period *(check the box) WORKSITE DETAILS You, the Installer of the installation Worksite Project Manager (if different from the worksite) Company: Represented by: Position: Address: Company: Address: Company: Represented by: Position: Address: Signature and Company Stamp preceded by the words certifies having carried out the installation Represented by: Position: Telephone: Fax: Building: Floor: Area: Signature and Company Stamp Signature and Company Stamp

THE 14 KEY POINTS OF AN INSTALLATION 1 Create a star architecture as defined in ISO IEC 11 801 and EIA/TIA 568. 2 Select a uniform performance category for all components in the installation (user cord, end socket, cable, patch panel, patch cord). 3 Install the cable, taking care to maintain a bending radius of at least eight times the cable diameter. 4 Comply with the separation distances for LV and ELV as defined in standard EN 50174-2 (see Appendix 1). 5 Cross LV and ELV cables at right angles. 6 Maintain a minimum distance between data cables and sources of interference (see Appendix 2) (UTE C15 900). 7 A main equipotential link must connect: The main earthing terminal Any earth electrode installed Metal trunking Protective earth conductors. 11 Carry out an acceptance test on the installation covering all the links to which the warranty applies.the test must comply with the specifications for the class and category installed. 12 if using screened or shielded cables: The exposed conductive parts must be connected at both ends. All channel components must be screened or shielded in the same way. 13 during the acceptance test, enter the NVP parameter (cable propagation speed) on the tester. 14 Install the cables under the conditions described in Guide 15 900. If using trunking or profiled ducting, install networks in different compartments in decreasing order of sensitivity to the ground plane (the most sensitive network being the closest to the ground plane). 8 Ensure continuity of metal ducts (see Appendix 3). 9 Use the shortest possible connections to link the exposed conductive parts of all equipment and ducting to the earthing system (see Appendix 4). 10 Maintain a maximum untwisted length of 13 mm. Signature and stamp of the INSTALLER (preceded by the words «certifies having carried out the installation») Location...... Date......

appendices - the 14 key points of an installation APPENDIX 1 Environments subject to a great deal of interference or sensitive computer systems In the case of environments subject to a great deal of interference or sensitive computer systems, it is recommended that shielded components are used and connected to ground throughout 360 In horizontal trunking, the sockets are installed in the same compartment as the cable to which they are connected. Separation of information technology (IT) cables and power supply cables. (Horizontal and vertical wiring) Without separation or non-metallic Type of installation Unscreened Screened separation Aluminium separation Steel separation Electric cable IT cable 200 mm 110 mm 50 mm Electric cable IT cable 50 mm 20 mm 5 mm Electric cable IT cable 30 mm 10 mm 2 mm Electric cable IT cable 0 mm 0 mm 0 mm APPENDIX 2 Sources of interference Fluorescent luminaires: distance 50 cm min. Motors, air conditioning units, industrial and medical equipment: distance 1 m min. APPENDIX 3 Sources of interference It is recommended that the shape of the metal cross-section is maintained along its entire length. APPENDIX 4 Equipotential links When a building is constructed, it is advisable to create a meshed ground system. The equipotential links with this ground system must be: As numerous as possible As short as possible (< 50 cm) Made of flat copper or braid (as wide as possible) service Relations Pro NO YES 0810 48 48 48 (local call rate) Monday to Friday 8h à 18h Postal address: 128 av. de Lattre de Tassigny 87045 Limoges Cedex - France Fax: 0810 48 00 00 (local call rate) E-mail: accessible sur legrand.fr Mai 2009

Structured cabling systems categories 6a, 6 & 5e 20 years warranty Components Customer copy Legrand copy

PURPOSE OF THE AGREEMENT 20-YEAR COMPONENTS WARRANTY 20-YEAR SYSTEM COMPONENTS WARRANTY Legrand offers the Installer the opportunity to extend the usual 2-year warranty to 20 years and undertakes to replace the following link or channel components: Patch cord Patch panel Cable RJ 45 socket User cord Area distribution box BETWEEN: LEGRAND SA, limited company with share capital of 56,320,674 Euros, registered with the Limoges Commercial and Company register, registration no. 758501001, whose head office is located at 128, av. du Mal de Lattre de Tassigny, 87 045 Limoges Cedex, acting on its own behalf and on behalf of LEGRAND SNC which it controls, represented by Mr (First Name-Surname)... acting in his capacity as (Position)...... and who is fully empowered to act for the purposes of this document, hereafter referred to as LEGRAND. AND: The company (Name, Legal Status, Share capital, Company Registration number and Head Office)........................... This 20-year Components warranty agreement must be completed and signed in duplicate. Send the Legrand copy, together with the Installation Identity Document, the acceptance test documentation, the product layout plan and, if applicable, the 20-year Performance warranty agreement to: Represented by Mr (First Name-Surname)... acting in his capacity as (Position)...... Legrand Relations Pro Service 128 av. de Lattre de Tassigny 87045 Limoges Cedex - France as declared by him, and who is fully empowered to act for the purposes of this document, hereafter referred to as THE INSTALLER, and together referred to as THE PARTIES.

AGREEMENT PREAMBLE LEGRAND, under certain combined eligibility conditions, offers to warranty the components of Cat 6A, Cat 6 or Cat 5e LCS2 cabling systems for 20 years, by granting an 18-year WARRANTY EXTENSION to the contractual LEGRAND warranty for products, hereafter referred to as CABLING SYSTEM PRODUCTS. THE INSTALLER has indicated an interest in obtaining this CABLING SYSTEM PRODUCTS WARRANTY. THE PARTIES have opened up negotiations to finalise the granting of this warranty to the INSTALLER. The Parties have accordingly agreed the following: ART 1. Definitions 1) CABLING SYSTEM PRODUCTS means those products included in the list of VDI products that can be covered by a separate warranty (see list of products attached to the Installation Identity Document). 2) WARRANTY EXTENSION means a period in addition to the initial 2-year warranty covering correct operation of the products, granted by LEGRAND, and an eighteen (18) year extension of the warranty covering correct operation on products referred to as CABLING SYSTEM PRODUCTS, excluding any other products or equipment. ART 2. Purpose The purpose of this agreement is to define the conditions under which LEGRAND provides the INSTALLER, considered here as intuitu personae, with the CABLING SYSTEM PRODUCTS WARRANTY on the components in a Category 5e or Category 6 installation for CABLING SYSTEM PRODUCTS, agreeing on a period in addition to the initial warranty covering correct operation of the products, granted by LEGRAND, and excluding any other products and equipment. ART 3. Conditions for granting the warranty The Warranty only applies to the installation carried out at the worksite for which the details are given in the Installation Identity Document. THE INSTALLER can only benefit from the warranty if all the following conditions have been met: The Installer has stored the components used in the installation under storage conditions that are appropriate to their nature. The Installer has carried out the installation in strict compliance with good practice and in accordance with the following combination of conditions: - The installation must be carried out in accordance with the rules defined by the installation standards EN 50174, NFC 15900, EN 55022 and ISO 11801 or NF EN 50173, which are in force on the date the Warranty is granted. - The components of this installation must be used under the conditions for which they have been designed. As well as the signed agreement, the Installer has delivered to LEGRAND the Installation Identity Document, consisting of: - The completed Worksite Details - Lists of VDI PRODUCTS with their quantities - A copy of the installed equipment layout plan bearing the installer s company stamp. Any subsequent modifications must comply with the conditions listed above. Any new phase of work type extension to the installation must form the subject of a new agreement. LEGRAND reserves the right to cancel this Warranty agreement at any time if the INSTALLER fails to fulfil any of the obligations defined by the agreement or in the event of attempted fraud by the Installer.

ART 4. Duration of the warranty granted to the installer The 20-YEAR COMPONENTS WARRANTY is granted to the INSTALLER for a period of twenty (20) years i.e. an eighteen (18) year extension of the warranty covering correct operation on the products referred to as CABLING SYSTEM PRODUCTS. Should the INSTALLER cease trading after the agreement has come into effect, the Project Owner or Project Manager must direct the Installer s successor to LEGRAND. ART 5. Warranty coverage In all applicable cases, if the products no longer operate correctly as defined in article 1, as a result of a product fault, the warranty covers the supply of the spare parts needed to repair the product, its outright replacement or the supply of a product with equivalent characteristics and performance that will restore the installation, excluding all other costs, charges and compensation. This warranty applies if the products have been stored, installed and maintained in accordance with good practice, current standards and the specifications in the LEGRAND catalogues and operating instructions, and if their failure is not the result of abnormal use, negligence, malicious intent, or an external accident. ART 6. Scope Privity The 20-YEAR COMPONENTS WARRANTY is granted exclusively to the INSTALLER of the system. It can only be granted for the worksite identified in the Installation Identity Document. It does not cover either the installation of the channel or any resulting indirect damage. It may not under any circumstances be transferred or assigned. ART 7. Effective date of coverage The 20-YEAR COMPONENTS WARRANTY takes effect as soon as this agreement is signed by LEGRAND. The agreement will only be signed when LEGRAND has: received the Installation Identity Document completed, checked and signed by the INSTALLER. examined and validated the Installation Identity Document and finally confirmed the installation, indicating its agreement by signing. Executed at/in... On... In two original copies, with each Party receiving a copy. For LEGRAND For the INSTALLER Mr... (First Name, Surname, Position, Company Stamp) Mr... (First Name, Surname, Position, Company Stamp) service Relations Pro Mai 2009 0810 48 48 48 (local call rate) Monday to Friday 8h à 18h Postal address: 128 av. de Lattre de Tassigny 87045 Limoges Cedex - France Fax: 0810 48 00 00 (local call rate) E-mail: accessible on legrand.fr

Structured cabling Systems categories 6a, 6 & 5e 20 years warranty System Customer copy Legrand copy

PURPOSE OF THE AGREEMENT 20-YEAR WARRANTY LINK OR CHANNEL PERFORMANCE Legrand offers the Installer the opportunity to warranty the long-term continuity of performance of a Cat 6a, Cat 6 or Cat 5e LCS 2 cabling system. Link > assembly of the following components: Patch panel Cable RJ 45 socket Area distribution box Performance is measured over a maximum length of 90 m. + 3-YEAR WARRANTY EXTENSION ON ADDITIONAL PRODUCTS By taking out the Performance warranty opposite, the usual 2-year Legrand warranty is extended to 5 years for the following products Enclosures Cabinets Patching accessories (feedthroughs, shelves, etc.). Channel > assembly of the following components: Patch cord Patch panel Cable RJ 45 socket User cord Area distribution box Performance is measured over a maximum length of 100 m. This 20-year Performance warranty agreement must be completed and signed in duplicate. The Legrand copy must be sent, together with the Installation Identity Document, the acceptance test documentation, the product layout plan and, if applicable, the 20-year Components Warranty agreement, to: Legrand Relations Pro Service 128 av. de Lattre de Tassigny 87045 Limoges Cedex - France

20-YEAR PERFORMANCE WARRANTY AGREEMENT + 3-YEAR EXTENSION FOR ADDITIONAL BETWEEN: LEGRAND SA, limited company with share capital of 56,320,674 Euros, registered with the Limoges Commercial and Company register, registration no. 758501001, whose head office is located at 128, av. du Mal de Lattre de Tassigny, 87 045 Limoges Cedex, acting on its own behalf and on behalf of LEGRAND SNC which it controls, represented by Mr (First Name-Surname)... acting in his capacity as (Position)...... et ayant tous pouvoirs pour agir aux fins des présentes ci-après désignée LEGRAND. AND: The company (Name, Legal Status, Share capital, Company Registration number and Head Office)........................... Represented by Mr (First Name-Surname)... acting in his capacity as (Position)...... as declared by him, and who is fully empowered to act for the purposes of this document: hereafter referred to as THE INSTALLER, and together referred to as THE PARTIES. PREAMBLE LEGRAND, under certain combined eligibility conditions, offers to warranty the performance of a Cat 6a, Cat 6 or Cat 5e LCS2 VDI cabling system consisting of a class D category 5e or class E, category 6 (for class EA and Cat 6A) channel or link. LEGRAND, under certain combined eligibility conditions, offers to extend the contractual warranty of the LEGRAND products hereafter referred to as ADDITIONAL PRODUCTS. Products constituting the link or channel and referred to as VDI products can be subject to an extension of the contractual warranty by means of a specific agreement. The INSTALLER has indicated an interest in obtaining this 20-year Performance Warranty. THE PARTIES have opened up negotiations to finalise the granting of this warranty to the INSTALLER. The Parties have accordingly agreed the following: ART 1. Definitions 1) PERFORMANCE means the conformity of the channel to the performance standards agreed by the Parties at the time the Warranty is granted. 2) PERFORMANCE STANDARDS means standards ISO 11801, EN 50173, EIA/TIA 568A and 568B or category 6A links according to the only published reference system: EIA/TIA 568B210. 3) LINK means the assembly of LEGRAND branded products or LEGRAND approved products used in LEGRAND Cat 6A, Cat 6 and Cat 5e LCS2 cabling systems: patch panels, RJ 45 sockets, installation cable (see list attached to the Installation Identity Document). 4) CHANNEL means the assembly of LEGRAND branded products or LEGRAND approved products used in LEGRAND Cat 6A, Cat 6 and Cat 5e LCS2 cabling systems: patch panels, RJ 45 sockets, installation cable, patch cords, user cords (see list attached to the Installation Identity Document).

PRODUCTS 5) VDI PRODUCTS means the products included in the list of VDI products attached to the Installation Identity Document, that can be covered by a separate warranty. 6) ADDITIONAL PRODUCTS means the products included in the additional products list attached to the Installation Identity Document, with quantities completed by the INSTALLER. 7) WARRANTY EXTENSION means a period in addition to the initial warranty covering correct operation of the products granted by LEGRAND, and a three (3) year extension of the warranty covering correct operation on products referred to as ADDITIONAL PRODUCTS, excluding all other products and equipment. ART 2. Purpose The purpose of this agreement is to define the conditions under which LEGRAND provides the INSTALLER, considered here as intuitu personae, with the 20-YEAR PERFORMANCE WARRANTY on the Category 5e or Category 6 channel or link for VDI products and additional products, agreeing on a period in addition to the initial warranty covering correct operation granted by LEGRAND, and excluding any other products and equipment. ART 3. Conditions for granting the warranty The Warranty only applies to the installation carried out at the worksite for which the details are given in the Installation Identity Document. THE INSTALLER can only benefit from the Warranty if all the following conditions have been met: The Installer has stored the components used in the installation under conditions that are appropriate to their nature. The Installer has carried out the installation in strict compliance with good practice and in accordance with the following combination of conditions: - All the components used in the cabling system must be Category 5e or 6 components of LEGRAND LCS5 or LCS6 cabling systems, listed in the Installation Identity Document, or failing that, products recommended and approved by LEGRAND. - The installation must be carried out in accordance with the rules defined in installation standards EN 50174, NFC 15900, EN 55022 and ISO 11801 or NF EN 50173, which are in force on the date the Warranty is granted. - For a CHANNEL Performance Warranty, all the patch cords and user cords must be original LEGRAND components. The length of a patch cord is limited to 5 metres. As well as the signed agreement, the Installer has delivered to LEGRAND the Installation Identity Document, consisting of: - The completed Worksite Details - Lists of VDI PRODUCTS and ADDITIONAL PRODUCTS with their quantities - The 14 key points document completed, checked and signed to indicate that the INSTALLER has complied with these points - A copy of the installed equipment layout plan bearing the installer s company stamp - Documentation on the installation acceptance test carried out in accordance with current standards. LEGRAND must ensure that the data for the installation acceptance test submitted by the INSTALLER conforms to the values specified in the performance standards. Any subsequent modifications must comply with the conditions listed above. Any new phase of work type extension to the installation must form the subject of a new agreement. LEGRAND reserves the right to cancel this Warranty agreement at any time if the INSTALLER fails to fulfil any of the obligations defined by the agreement or in the event of attempted fraud by the Installer. >

ART 4. Duration of the warranty granted to the installer The Performance Warranty is granted to the INSTALLER for a period of twenty (20) years. In addition, the INSTALLER will benefit from a warranty of five (5) years on ADDITIONAL PRODUCTS, i.e. a three (3) year extension of the warranty covering correct operation on ADDITIONAL PRODUCTS, provided that the channel or link covered by the warranty consists entirely of LEGRAND products. Should the INSTALLER cease trading after the agreement has come into effect, the Project Owner or Project Manager must direct the Installer s successor to LEGRAND. ART 5. Performance warranty coverage In all applicable cases, if the level of performance defined in article 1 is no longer provided as the result of a product fault, the warranty covers the supply of the spare parts needed to repair the product, its outright replacement or the supply of a product with equivalent characteristics and performance that will restore the installation, excluding all other costs, charges and compensation. This warranty applies if the products have been stored, installed and maintained in accordance with good practice, current standards and the specifications in the LEGRAND catalogues and operating instructions, and if their failure is not the result of abnormal use, negligence, malicious intent, or an external accident. ART 6. Scope Privity The 20-YEAR PERFORMANCE WARRANTY is granted exclusively to the INSTALLER of the LEGRAND VDI system. It can only be granted for the worksite identified in the Installation Identity Document. It does not cover either the installation of the channel or any resulting indirect damage. It may not under any circumstances be transferred or assigned. ART 7. Effective date of coverage The 20-YEAR PERFORMANCE WARRANTY takes effect as soon as this agreement is signed by LEGRAND. The agreement will only be signed when LEGRAND has: received the Installation Identity Document completed, checked and signed by the INSTALLER. examined and validated the Installation Identity Document and finally confirmed the installation, indicating its agreement by signing. Executed at/in... On... In two original copies, with each Party receiving a copy. For LEGRAND For the INSTALLER Mr... (First Name, Surname, Position, Company Stamp) Mr... (First Name, Surname, Position, Company Stamp)

service Relations Pro Mai 2009 0810 48 48 48 (local call rate) Monday to Friday 8h à 18h Postal address: 128 av. de Lattre de Tassigny 87045 Limoges Cedex - France Fax: 0810 48 00 00 (local call rate) E-mail: accessible on legrand.fr

LIST OF VDI PRODUCTS quantity to be completed by the INSTALLER in order to obtain: the 20-YEAR PERFORMANCE WARRANTY and/or the 20-YEAR COMPONENTS WARRANTY DESCRIPTION Cat.Nos Quantity Patch panels with connector Equipped panel - 1 U - contacts 4-5/7-8 - for analogue telephone - LCS 2 33530... Equipped panel - 1 U - contacts 3-6/4-5 - for digital telephone - LCS 2 33531... Equipped patch panel - 19'' - 1 U - Cat. 5e - UTP - LCS 2 33551... Equipped patch panel - 19'' - 1 U - Cat. 5e - FTP - LCS 2 33552... Equipped patch panel - 19'' - 1 U - Cat. 6 - UTP - LCS 2 33561... Equipped patch panel - 19'' - 1 U - Cat. 6 - FTP - LCS 2 33562... Equipped patch panel - 19'' - 1 U - Cat. 6 - STP - Metal shielding - LCS 2 33563... Equipped patch panel - 19" - 1 U - Cat. 6a - STP - Metal shielding - LCS 2 33573... Patch panels to be equipped Patch panel to be equipped - 19-1 U - LCS 2 33590... Patch panel to be equipped - 10-1 U - LCS 2 33592... Blocks for panels to be equipped, Copper TOTAL OF PANELS... 6-connector block RJ 45 - Cat. 5 - UTP - for patch panel to be equipped - LCS 2 33554... 6-connector block RJ 45 - Cat. 5 - FTP - for patch panel to be equipped - LCS 2 33555... 6-connector block RJ 45 - Cat. 6 - UTP - LCS 2 33564... 6-connector block RJ 45 - Cat. 6 - FTP - LCS 2 33565... 6-connector block RJ 45 - Cat. 6 - STP - Metal shielding - LCS 2 33566... 6-connector block RJ 45 - Cat. 6a - STP - Metal - for 19 patch panel - LCS 2 33576... End sockets Mosaic RJ 45 socket Mosaic Prog - Cat. 6 - FTP - Green flap - 2 mod - White - LCS 2 76522... RJ 45 socket Mosaic Prog - Cat. 6 - FTP - Orange flap - 2 mod - White - LCS 2 76523... RJ 45 socket Mosaic Prog - Cat. 6a - STP - Green flap - 2 mod - White - LCS 2 76524... RJ 45 socket Mosaic Prog - Cat. 6a - STP - Orange flap - 2 mod - White - LCS 2 76525... Double RJ 45 socket Mosaic Prog Direct clip-on trunking - Cat. 5e - FTP - 3 mod - LCS 2 76542... Double RJ 45 socket Mosaic Prog Direct clip-on trunking - Cat. 6 - FTP - 3 mod - LCS 2 76546... RJ 45 socket Mosaic Prog - Cat. 5e - UTP - 1 mod - White - LCS 2 76551... RJ 45 socket Mosaic Prog - Cat. 5e - FTP - 1 mod - White - LCS 2 76552... RJ 45 socket Mosaic Prog - Cat. 5e - UTP - 2 mod - White - LCS 2 76554... RJ 45 socket Mosaic Prog - Cat. 5e - FTP - 2 mod - White - LCS 2 76555... RJ 45 socket Mosaic Prog - Cat. 6 UTP - 1 mod - White - LCS 2 76561... RJ 45 socket Mosaic Prog - Cat. 6 - FTP - 1 mod - White - LCS 2 76562... RJ 45 socket Mosaic Prog - Cat. 6 - STP - Metal shielding - 1 mod - White - LCS 2 76563... RJ 45 socket Mosaic Prog - Cat. 6 UTP - 2 mod - White - LCS 2 76564... Customer Copy Legrand copy

LIST OF VDI PRODUCTS (continued) DESCRIPTION Cat.Nos Quantity RJ 45 socket Mosaic Prog - Cat. 6 - FTP - 2 mod - white - LCS 2 76565... RJ 45 socket Mosaic Prog - Cat. 6 - STP - Metal shielding - 2 mod - white - LCS 2 76566... RJ 45 socket Mosaic Prog - Cat. 6a - STP - 1 mod - white - LCS 2 76573... RJ 45 socket Mosaic Prog - Cat. 6a - STP - 2 mod - white - LCS 2 76576... RJ 45 socket Mosaic Prog - Cat. 6 - FTP - antibacterial - 1 mod - white - LCS 2 76582... RJ 45 socket Mosaic Prog - Cat. 6 - STP - shielded - 1 mod - antibacterial - white - LCS 2 76583... RJ 45 socket Mosaic Prog - Cat. 6 - UTP - 90 socket - 2 mod - white - LCS 2 76591... RJ 45 socket Mosaic Prog - Cat. 6 - FTP - 90 socket - 2 mod - white - LCS 2 76592... RJ 45 socket Mosaic Prog - Cat. 6 - STP - Metal shielding - 90-2 mod - white 76593... RJ 45 socket Mosaic Prog - controlled access - Cat. 6 - UTP - 2 mod - white - LCS 2 76594... RJ 45 socket Mosaic Prog - controlled access - Cat. 6 - FTP - 2 mod - white - LCS 2 76595... RJ 45 socket Mosaic Prog - Cat. 6 - STP - Metal shielding - 2 keys - 2 mod - white - LCS 2 76596... RJ 45 socket Mosaic Prog - controlled access - Cat. 6A - STP - 2 mod - white - LCS 2 76599... RJ 45 socket Soliroc Prog - Cat. 6 - FTP - IK 10 - IP 20 - LCS 2 77891... RJ 45 socket Mosaic Prog - Cat. 5e - FTP - 1 mod - aluminium - LCS 2 79452... RJ 45 socket Mosaic Prog - Cat. 5e - FTP - 2 mod - aluminium - LCS 2 79455... RJ 45 socket Mosaic Prog - Cat. 6 UTP - 8-contact - 1 mod - aluminium 79461... RJ 45 socket Mosaic Prog - Cat. 6 - FTP - 1 mod - aluminium - LCS 2 79462... RJ 45 socket Mosaic Prog - Cat. 6 - UTP - 2 mod - aluminium - LCS 2 79464... RJ 45 socket Mosaic Prog - Cat. 6 - FTP - 2 mod - aluminium - LCS 2 79465... RJ 45 socket Mosaic Prog - Cat. 6a - STP - 1 mod - aluminium 79473... RJ 45 socket Mosaic Prog - Cat. 6a - STP - 2 mod - white 79476... RJ 45 socket Mosaic Prog - Cat. 6 - FTP - 90 socket - 2 mod - aluminium - LCS 2 79492... Céliane RJ 45 socket Céliane Prog - Cat. 6 - UTP - LCS 2 67344... RJ 45 socket Céliane Prog - Cat. 6 - FTP - LCS 2 67345... RJ 45 socket Céliane Prog - Cat. 6a - STP - Metal shielding - LCS 2 67346... Plexo RJ 45 socket Plexo Prog - Cat. 5e - UTP - IP 55 flap closed IK 07 - LCS 2 69556... RJ 45 socket Plexo Prog - Cat. 5e - FTP - IP 55 flap closed IK 07 - LCS 2 69557... RJ 45 socket Plexo Prog - Cat. 6 - UTP - IP 55 flap closed IK 07 - LCS 2 69561... RJ 45 socket Plexo Prog - Cat. 6 - FTP - IP 55 flap closed IK 07 - LCS 2 69569... TOTAL OF END SOCKETS...

LIST OF VDI PRODUCTS (continued) DESCRIPTION Cat.NoS Quantity Cables LAN cable - Cat. 5e - F/UTP - 4 pairs - LSOH - L. 500 m - LCS 2 32850... LAN cable - Cat. 5e - U/UTP - 4 pairs - LSOH - L. 500 m - LCS 2 32853... LAN cable - Cat. 5e - U/UTP - 2 x 4 pairs - LSOH - L. 500 m - LCS 2 32855... LAN cable - Cat. 6 - F/UTP - 4 pairs - L. 500 m - Wt. 17 kg - LCS 2 32856... LAN cable - Cat. 6 - SF/UTP - 2 x 4 pairs - L. 500 m - Wt. 52 kg - LCS 2 32859... LAN cable - Cat. 6 - U/UTP - 4 pairs - L. 500 m - Wt. 18 kg - LCS 2 32861... LAN cable - Cat. 6 - U/UTP - 2 x 4 pairs - L. 500 m - Wt. 38 kg - LCS 2 32863... Cable for LANs - Cat.7 - S/FTP - 4 pairs - L. 500 m 32777... Cable for LANs - Cat. 6A - F/UTP - 4 pairs - L. 500m 32778... Cable for LANs - Cat.6 - U/UTP - 4 pairs - LSOH - L. 305 m 32754... Cable for LANs - Cat.6 - F/UTP - 4 pairs - LSOH - L. 500 m 32756... Cable for LANs - Cat.6 - SF/UTP - 4 pairs - LSOH - L. 500 m 32757... Cable for LANs - Cat.6 - F/UTP - 2 x 4 pairs - LSOH - L. 500 m 32776... Cable for LANs - Cat.5e - F/UTP - 2 x 4 pairs - LSOH - L. 500 m 32774... Cable for LANs - Cat.5e - U/UTP - 4 pairs - LSOH - L. 305 m 32750... Cords Patch cord RJ 45 - Cat. 6a - SF/UTP shielded - L. 1 m 51780... Patch cord RJ 45 - Cat. 6a - SF/UTP shielded - L. 2 m 51781... Patch cord RJ 45 - Cat. 6a - SF/UTP shielded - L. 3 m 51782... Patch cord RJ 45 - Cat. 6a - SF/UTP shielded - L. 5 m 51783... Patch cord RJ 45 - Cat.6 - SF/UTP shielded - L. 1 m 51752... Patch cord RJ 45 - Cat.6 - SF/UTP shielded - L. 5 m 51755... Patch cord RJ 45 - Cat.6 - F/UTP screened - L. 1 m 51762... Patch cord RJ 45 - Cat.6 - F/UTP screened - L. 2 m 51763... Patch cord RJ 45 - Cat.6 - F/UTP screened - L. 3 m 51764... Patch cord RJ 45 - Cat.6 - F/UTP screened - L. 5 m 51765... Patch cord RJ 45 - Cat.5e - F/UTP screened - L. 1 m 51640... Patch cord RJ 45 - Cat.5e - F/UTP screened - L. 5 m 51643... Patch cord RJ 45 - Cat.5e - F/UTP screened - L. 1 m 51640... Cord for mixed/basic network RJ 45-RJ 45 - Cat.5e - F/UTP - L. 2 m 51641... Cord for mixed/basic network RJ 45-RJ 45 - Cat.5e - F/UTP - L. 3 m 51642... Patch cord RJ45 - Cat.5e - F/UTP screened - L. 5 m 51643... Area distribution box Area distribution box to be equipped - Cat. 6a/6/5e - for connector block - LCS 2 33540... Equipped area distribution box - Cat. 6 - UTP 12-connector RJ 45 - LCS 2 33544... Equipped area distribution box - Cat. 6 - FTP 12-connectors RJ 45 - LCS 2 33545... Equipped area distribution box - Cat. 6 - STP 12-connectors RJ 45 - LCS 2 33546...

LIST OF ADDITIONAL PRODUCTS List of ADDITIONAL PRODUCTS, quantity to be completed by the INSTALLER to receive a three (3) year extension of the warranty covering correct operation within the framework of the 20-YEAR PERFORMANCE WARRANTY, provided that the channel or link covered by the warranty consists entirely of LEGRAND products. DESCRIPTION Cat.NoS Quantity LCS 2 cabinet Cabinet depth 400 19'' LCS 2 fixed cabinet - IP20-IK08-6 U - 350x600x400 mm 46200... 19'' LCS 2 fixed cabinet - IP20-IK08-9 U - 500x600x400 mm 46201... 19'' LCS 2 fixed cabinet - IP20-IK08-12 U - 600x600x400 mm 46202... 19'' LCS 2 fixed cabinet - IP20-IK08-16 U - 800x600x400 mm 46203... Cabinet depth 580 19'' LCS 2 fixed cabinet - IP20-IK08-9 U - 500x600x580 mm 46206... 19'' LCS 2 fixed cabinet - IP20-IK08-12 U - 600x600x580 mm 46207... 19'' LCS 2 fixed cabinet - IP20-IK08-16 U - 800x600x580 mm 46208... 19'' LCS 2 fixed cabinet - IP20-IK08-21 U - 1000x600x580 mm 46209... Cabinet depth 600 19'' LCS 2 pivoting cabinet - IP20-IK08-9 U - 500x600x600 mm 46211... 19'' LCS 2 pivoting cabinet - IP20-IK08-12 U - 600x600x600 mm 46212... 19'' LCS 2 pivoting cabinet - IP20-IK08-16 U - 800x600x600 mm 46213... 19'' LCS 2 pivoting cabinet - IP20-IK08-21 U - 1000x600x600 mm 46214... 10'' LCS 2 mini cabinet - IP 20 - IK 08-6 U - 350x340x300 mm 46220... LCS 2 rack Depth 600 19'' LCS 2 rack - metal - 24 U - 1226x600x600 mm 46300... 19'' LCS 2 rack - metal - 29 U - 1448x600x600 mm 46306... 19'' LCS 2 rack - metal - 33 U - 1626x600x600 mm 46312... 19'' LCS 2 rack - metal - 42 U - 2026x600x600 mm 46318... 19'' LCS 2 rack - metal - 42 U - 2026x800x600 mm 46321... 19'' LCS 2 extension rack - metal - 42 U - 2026x600x600 mm 46330... Depth 800 19'' LCS 2 rack - metal - 42 U - 2026x600x800 mm 46319... 19'' LCS 2 rack - metal - 42 U - 2026x800x800 mm 46322... 19'' LCS 2 rack - metal - 47 U - 2248x800x800 mm 46328... 19'' LCS 2 extension rack - metal - 42 U - 2026x800x800 mm 46333... Depth 1000 19'' LCS 2 rack - metal - 42 U - 2026x800x1000 mm 46323... 19'' LCS 2 rack - metal - 47 U - 2248x800x1000 mm 46329...

LIST OF ADDITIONAL PRODUCTS (continued) DESCRIPTION Cat.NoS Quantity Cabinet accessories Fixed shelf - 1 U - depth 120 mm - for 10'' LCS 2 cabinet 46223... Power supply unit 230 VA - 4 x 2P+E - for 10'' LCS 2 cabinet 46224... Power supply unit for equipping with Mosaic 2P+E sockets - 8 mod - 10'' LCS 2 cabinet 46225... Cable entry plate with brushes - for LCS 2 pivoting cabinets 46255... Fan - 230 VA - heat management for 19'' LCS 2 cabinets 46260... Castors (4) - for fitting on 19'' LCS 2 pivoting cabinets 46264... Rack accessories Cabling unit - for 19'' LCS 2 racks depth 600 mm - LCS 2 46334... Cabling unit - for 19'' LCS 2 racks depth 800 mm - LCS 2 46335... Joining kit for 2 x 600 mm deep LCS 2 racks - LCS 2 46337... Joining kit for 2 x 800 mm deep LCS 2 racks - LCS 2 46338... Joining kit for 2 x 1000 mm deep LCS 2 racks - LCS 2 46339... Plinth kit - H. 100 mm - for 600 m width LCS 2 racks - opening on all 4 sides - LCS 2 46450... Plinth kit - H. 100 mm - for 800 m width LCS 2 racks - opening on all 4 sides - LCS 2 46451... Plinth kit - H. 200 mm - for 600 m width LCS 2 racks - opening on all 4 sides - LCS 2 46452... Plinth kit - H. 200 mm - for 800 m width LCS 2 racks - opening on all 4 sides - LCS 2 46453... Solid side trap (2) - H. 100 mm - for 600 mm depth rack - LCS 2 46454... Solid side trap (2) - H. 100 mm - for 800 mm depth rack - LCS 2 46456... Solid side trap (2) - H. 100 mm - for 1000 mm depth rack - LCS 2 46458... Ventilated trap - H. 100 mm - for racks width/depth 600 mm - LCS 2 46460... Ventilated trap - H. 100 mm - for racks width/depth 800 mm - LCS 2 46461... Trap with brushes - H. 100 mm - for racks width/depth 600 mm - LCS 2 46462... Trap with brushes - H. 100 mm - for racks width/depth 800 mm - LCS 2 46463... Plinth for cabling units Cat.Nos 463 34/35 - LCS 2 46464... Linking interface for 600 mm deep LCS2 rack - LCS 2 46466... Support for holding cables (2) - for racks width/depth 600 mm - LCS 2 46472... Support for holding cables (2) - for racks width/depth 800 mm - LCS 2 46473... Support for holding cables (2) - for racks width/depth 1000 mm - LCS 2 46474... Flat cable guide - width 250 mm - for 33 U rack - LCS 2 46476... Flat cable guide - width 250 mm - for 42 U rack - LCS 2 46477... Patch extension upright (2) - for 19 racks 42 U - width 800 mm - LCS 2 46481... Castors (4) - for fitting on LCS 2 racks 46483... Lighting kit - 230 VA - for LCS 2 racks 46485... 19'' plate - 3 U - with two 230 VA fans - heat management of racks - LCS 2 46487... 19'' plate - 3 U - with three 230 VA fans - heat management of racks - LCS 2 46488... Cable guide ring - 1 U - usable cross-section 1890 m 2 - plastic - LCS 2 46541... Cable guide ring - 2 U - usable cross-section 4070 m 2 - plastic - LCS 2 46542... DIN rail kit IP 2X - for fitting Lexic equipment - for LCS 2 and Altis racks 46545... Linking bar - for metal Altis enclosures width/depth 600 mm 47693... Linking bar - for metal Altis enclosures width/depth 800 mm 47694... 19'' uprights (2) - 42 U - for Altis enclosures - LCS 2 48220... Thermostat - for 19'' XL-VDI-LCS 2 cabinet/enclosure - 5 to 60 C - 12 to 250 VA 34848... Bag of 50 x 8.5 mm cage nuts/plastic washers/m6 screws - LCS 2 36453... Bag of 50 x 9.5 mm cage nuts/plastic washers/m6 screws - LCS 2 36454... 19'' power supply unit - 230 VA - 6 x 2P+E + 2P 16 A MCB - LCS 2 33237...

LIST OF ADDITIONAL PRODUCTS (continued) DESCRIPTION Cat.NoS Quantity 19'' power supply unit - 230 VA - 6 x 2P+E + voltage surge protector + switch with indicator light - LCS 2 33278... 19'' power supply unit - 230 VA to be equipped - takes 16 Mosaic modules - LCS 2 33279... 19'' power supply unit - 230 VA - 6 x 2P+E with switch with indicator light - LCS 2 33288... 19'' power supply unit - 230 VA - 6 x 2P+E tamperproof for UPS - LCS 2 33287... Feedthrough panels 19 19'' feedthrough panel - 1 U - 2 axes - metal - LCS 2 46522... 19'' feedthrough panel - 2 U - 2 axes - metal - LCS 2 46523... 19'' feedthrough panel - 1 U - with brushes - for fitting on LCS 2 racks plastic 46528... 19'' feedthrough panel - 2 U - with brushes - for fitting on LCS 2 racks - plastic 46529... 19'' feedthrough panel - 1 U - with brushes - for fitting on LCS 2 racks - metal 46530... 19'' feedthrough panel - 2 U - with brushes - for fitting on LCS 2 racks - metal 46531... Feedthrough panel (2) - for 19'' racks 42 U - width 800 mm - vertical - LCS 2 46480... Blanking plates 19'' blanking plate - 1 U - solid - for fitting on LCS 2 racks plastic 46532... 19'' blanking plate - 2 U - solid - for fitting on LCS 2 racks - plastic 46533... 19'' blanking plate - 1 U - solid - for fitting on all racks - metal - LCS 2 46538... 19'' blanking plate - 2 U - solid - for fitting on all racks - metal - LCS 2 46539... 19'' blanking plate - 3 U - solid - for fitting on all racks - metal - LCS 2 46540... Shelves Fixed shelf - H. 2 U - for LCS 2 racks and cabinets - depth 115 mm - LCS 2 46500... Fixed shelf - H. 2 U - for LCS 2 racks and cabinets - depth 200 mm - LCS 2 46501... Fixed shelf - H. 2 U - for LCS 2 racks and cabinets - depth 360 mm - LCS 2 46502... Fixed shelf - depth 450 mm - 19'' uprights (4) - for 600 mm deep racks - LCS 2 46505... Fixed shelf - depth 650 mm - 19'' uprights (4) - for 800 mm deep racks - LCS 2 46506... Fixed shelf - depth 850 mm - 19'' uprights (4) - for 1000 mm deep racks - LCS 2 46507... Telescopic shelf - depth 450 mm - 19'' uprights (4) - for 600 mm deep racks - LCS 2 46508... Telescopic shelf - depth 650 mm - 19'' uprights (4) - for 800 mm deep racks - LCS 2 46509... Telescopic shelf - depth 650 mm - 19'' uprights (4) - for 1000 mm deep racks - LCS 2 46510... Fixed slides (2) - 19'' uprights (4) - for 600 mm deep racks - LCS 2 46511... Fixed slides (2) - 19'' uprights (4) - for 800 mm deep racks - LCS 2 46512... Fixed slides (2) - 19'' uprights (4) - for 1000 mm deep racks - LCS 2 46513...