INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS



Similar documents
AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

SCION SQ Series GC-MS

DO MORE AND DO IT WITH CONFIDENCE. Empower 3 Chromatography Data Software

WATERS QUANTITATIVE ANALYSIS solutions

Pesticide Analysis by Mass Spectrometry

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Background Information

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies

MassHunter for Agilent GC/MS & GC/MS/MS

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Analyzing Small Molecules by EI and GC-MS. July 2014

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

QGA Quantitative Gas Analyser

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

LABWORKS Laboratory Information Management System. be confident. be informed. take control.

NexION 350 ICP-MS Maximum throughput. Minimum downtime. Optimum insight.

How To Use Gc-Ms

LC-MS/MS for Chromatographers

AMD Analysis & Technology AG

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

Thermo Scientific ExactFinder Software

Waters Core Chromatography Training (2 Days)

Tuning & Mass Calibration

IR READY TOGO. Spectrum Two FT-IR Spectroscopy

The Use of Hydrogen Carrier Gas for GC/MS

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

Research-grade Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, How I learned to ditch the triple quad and love the QE

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

GC-xt. The most flexible GC /GC-MS liquid sample injector

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

How To Build An Amd Quas 3 Ar Mass Spectrometer

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Expectations for GC-MS Lab

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

NUVISAN Pharma Services

C146-E087F. GCMS-QP2010 Plus. Shimadzu Gas Chromatograph Mass Spectrometer

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

Spectrum 10 Spectroscopy Software

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012.

Series 2. Continuous monitoring of trace chemical vapours

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

the fastest injection-to-injection time

Opiates in Urine by SAMHSA GC/MS

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

Volume 22 Number 22. C43-A ISBN ISSN Gas Chromatography/Mass Spectrometry (GC/MS) Confirmation of Drugs; Approved Guideline

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Mass Spectrometry Signal Calibration for Protein Quantitation

Retrospective Analysis of a Host Cell Protein Perfect Storm: Identifying Immunogenic Proteins and Fixing the Problem

aurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS

Agilent LCMS products and the application strategies in veterinary drug analysis

Process Instrumentation

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

THE WORLD S MOST EFFICIENT DATA CENTER

Clarus 580 Gas Chromatograph

Electrospray Ion Trap Mass Spectrometry. Introduction

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Analysis of Phthalate Esters in Children's Toys Using GC-MS

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis

Appendix 5 Overview of requirements in English

Transcription:

AxION iqt GC/MS/MS INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE

IDENTIFY WHAT YOU RE LOOKING FOR (AND EVEN WHAT YOU RE NOT)

The GC/MS/MS Solution for the Work You Do The ideal solution for industrial, chemical, petroleum, academia, and much more, the AxION iqt system delivers exceptional characterization of complex samples and even better confidence in your results. Here are just a few examples: Petroleum If jet fuels are not up to specification, they can freeze up, causing engines to malfunction. Cold EI technology can strongly enhance the fuel s hydrocarbon isomer molecular ions, enabling scientists to aid in the development of refining processes, monitor catalyst performance and refining yields and maximize product value. Food Characterization of aroma-contributing compounds in wine can play a huge part in quality control. Our AxION iqt system delivers full-scan mass spectral information and exceptional sensitivity perfect for detecting components at both trace levels and high concentrations. Personal Care Products Compounds in fragrances can cause severe allergic reactions in people who are sensitive to them. Analytical techniques that screen for these fragrance allergens in varied and complex matrices need to be developed. The AxION iqt system provides full product ion MS/MS information with no loss in sensitivity perfect for detecting sub-ppm levels of fragrance allergens. Forensics White-powder drug raids present special challenges for law enforcement and for laboratories. For example, amphetamines and their derivatives spectra often contain no molecular ions, so identification and confirmation can be difficult. The AxION iqt and Cold EI enable you to see the molecular ion, providing more selective MS/MS data. MORE CONFIDENCE NO COMPROMISE Researchers, application scientists, and lab technicians need to analyze a wide range of compounds in an even wider range of samples everything from food to jet fuel. And today s scientists need to identify known and unknown species based on both compound molecular ions and fragments, without loss of sensitivity. That s the whole idea behind the AxION iqt system. With its unique hybrid MS/MS design, the AxION iqt GC/MS/MS delivers greater confidence in compound identification and high-performance quantitation. Its parallel-reaction monitoring (PRM) capability delivers full product ion spectra with no loss in sensitivity compared to multiple-reaction monitoring (MRM) systems with exceptionally fast acquisition times and spectral acquisition rates. A carefully designed GC/MS interface permits high chromatographic gas flow rates, decreasing sample analysis time with up to twenty times the sample throughput. What s more, the AxION iqt is the only GC/MS/MS system to deliver fully integrated Cold EI technology a unique ionization source that substantially reduces the vibrational energy of molecules prior to ionization. This enhances the molecular ion, enabling confident compound identification and quantitation using both MS and MS/MS fragmentation while preserving spectral features for NIST library searching. Put that all together with our patented modular design, compact benchtop footprint, easy-to-use Mass IQ software, and industry-leading global service and support, and you have a solution you can depend on to deliver specific, selective data to support better decision making. And that means more far-reaching discovery. www.perkinelmer.com/axion 3

CONFIDENCE IS COLLECTING ALL YOUR FRAGMENTS ALL THE TIME Full-scan quantitation with no loss of sensitivity Whether you re developing new products or helping ensure that your existing products meet exacting regulatory and accreditation requirements, the AxION iqt delivers the confident molecular identification and precise quantification your samples require. With the AxION iqt, you can quantify across the entire mass range and detect all compounds in one experiment without compromising sensitivity. It delivers a linear dynamic range of 10 5, and can detect ions over a mass range of 10 u to 1,200 u. What s more, it delivers spectral acquisition rates of 50,000 u per second, with up to 500 MS/MS scans per second. Plus, its quad pulsar feature provides optimal ion transfer from the collision region to the TOF sections of the instrument for exceptional performance. And the AxION iqt system s MS/MS configuration enables you to discriminate between co-eluting peaks with confidence, for higher throughput and better productivity. What s more, the AxION iqt adapts to transfer lines of any length and seamlessly integrates with the industry-leading Clarus 680 GC gas chromatography system. Best of all, the system s smart-module design means that it s able to self-diagnose as well as self-optimize. Easy access to the modules means maintenance is fast and easy, delivering maximum uptime for busy analysts so service time is kept to a minimum. The AxION iqt system's curved-quad collision cell reduces noise for greater selectivity and fewer false positives. The result is an instrument that can identify and quantitate compounds across a wide concentration range even in the same run. 4

The inside story of the first MS/MS system of its kind The AxION iqt GC/MS/MS simplifies even the most complex sample analysis, by collecting the selected mass range in the second mass analyzer in parallel, eliminating the need for MRM or SIM modes. The AxION iqt system s time-of-flight configuration delivers: Full MS and MS/MS spectra with no loss of sensitivity over MRM or SIM operation Fast spectral acquisition rate up to 50,000 u per second Discrete modules for easy maintenance and fast repair ISO 13485 industry certification And that means higher quality data and more confidence in your results. Here s what s inside: The curved argon-filled collision cell (Q2) operates in continuous CID mode, depositing the optimum energy with no time overhead. The patented RF-focused TOF and detector, allows for a wide ion beam, delivering the dynamic range and sensitivities required for most complex matrices. The Quadrupole mass filter with pre- and post-ion guides (Q1) provides higher ion-transmission efficiencies and targeted mass selection of precursor ions for MS/MS. The 90 turn (Q0) eliminates unwanted ions and neutrals, reducing analyzer contamination. The interchangeable ion sources enable you to analyze a broader spectrum of compound classes in a single system. www.perkinelmer.com/axion 5

MASS SPEC TECHNOLOGY THAT BEATS THE OTHERS COLD The industry s first fully integrated Cold EI system One of the most important functions of conventional electron ionization (EI) GC/MS is to provide the molecular weight of a compound. But for many molecules, this important ion can be small or absent. For compounds with strong molecular ions, this is not a problem but for compounds such as amphetamines, it s significant. Enter Cold EI, a technology that can enhance molecular ion intensity. Molecules exiting the GC column are mixed with makeup carrier gas and then pass through a supersonic nozzle. Adiabatic expansion cools the analyte molecules in a supersonic molecular beam to ~15 K (-258 ºC) by reducing internal vibrational energy. Analyte molecules concentrate in the molecular beam s center,carrier gas is removed, and the cold analyte molecules enter the ion source for ionization. These molecules typically undergo less fragmentation than the hot molecules (around 250 C ) of conventional EI GC/MS because of the reduced vibrational energy. This increases confidence in your compound identification and structural confirmation and the uniqueness of the molecular ion gives you more specificity in your results. n-tetrapentacontane 100 57 - EI (NIST) 100 5771 71 85 50 85 50 99 113 99 141 0 183 113 211 239 267 295 323 351 379 421 141 446 474 504 531 560 588 616 644 672 700 729 758 80 120 160 183200 240 280 320 360 400 440 480 520 560 600 640 680 720 760 211 239 267 295 323 351 379 421 446 474 504 531 560 588 616 644 672 700 729 758 0 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720 760 n-tetrapentacontane - Cold EI 100 100 758 758 Supersonic cooling of molecules for Cold EI ionization. 50 50 71 0 0 57 97 71 113 155 183 211 239 266 294 322 364 392 420 447 489 532 559 588 631 701 728 57 769 97 113 120 160 200 240 280 320 360 400 440 480 520 560 155 183 211 239 364 392 420 447 489 532 559 588 600 631 640 701720 728 80 680 760 266 294 322 769 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720 760 n-tetrapentacontane (C 54 H 110 ) showing molecular ion enhancement of Cold EI spectrum (bottom) compared to NIST reference EI spectrum (top) A Filament That s in for the Long Haul Engineered to deliver many years of service analyzing the most complex chromatography samples, the Marathon Filament provides high resistance to demanding injections, including headspace and purge and trap and can even stand up to such challenging applications as flame-retardant analysis. Best of all, it s backward compatible with all systems using our previous rhenium filament solutions and it s standard equipment on our Clarus GC/MS systems. That s technology you can count on for the long run. 6

Easy-to-use Mass IQ software The AxION iqt system s Mass IQ software enables you to automatically generate fast, accurate results, and parallel reaction monitoring (PRMs) are quick and easy to set up with minimal method development no product ion selection required. All product ions are monitored all the time, without loss in sensitivity, for fast, accurate, and precise quantification. In addition, AxION iqt system software integrates seamlessly with our Clarus 680 GC for a hyphenated GC/MS/MS solution, providing complete control of the entire instrument. It delivers fast startup times, thanks to its Autotune, Autocalibrate, and Autocentroid (A 3 ) features. This straightforward interface offers streamlined features to optimize your day-to-day workflow. Integration to Bring Out the Best in Your Research The AxION iqt is not just a system, it s a solution and it draws much of its power from hyphenation with Clarus chromatographic instruments. Mass IQ Software for fast and accurate results. Clarus systems feature a unique, high-performance oven with the fastest heat-up and cool-down rates in a conventional GC available today together with enhanced temperatureprogrammable injectors. Even with the most challenging applications, the shorter injection-to-injection time can increase throughput and productivity by reducing analytical cycle time. And that means faster ROI for you. And the Clarus GC incorporates a host of other innovations that deliver outstanding operational simplicity and flexibility while removing the barriers to productivity that demanding samples and applications bring. The fastest temperatureprogrammable inlets available combined with programmable pneumatic control provide simple, straightforward solutions to complex analyses for instance, methanol in crude oil or determination of pesticides in food. www.perkinelmer.com/axion 7

Laboratory services that work the way you do With OneSource Laboratory Services, you have the world s largest and most respected global service and support network at your disposal. It s not just instrument maintenance and repair: We incorporate lab asset management strategies as part of your business equation, so you can improve efficiencies, optimize operations, and realize cost certainties across your organization. And with operations in more than 150 countries, and with more than 400,000 assets under our care, we re available 24/7, delivering the most comprehensive portfolio of professional laboratory services in the industry, including complete multivendor care. And that means you can consolidate your service contracts under a single supplier while we provide the expert technical support you need, whenever you need it. Care and repair, validation and compliance, asset management and lab relocation, upgrades, education, and much more OneSource is the one you can count on for it all. PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2015, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 012340_01 PKI