Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps
|
|
- Amber Dennis
- 8 years ago
- Views:
Transcription
1 Application Note: ANTV10 Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps Abstract In order to regulate product safety and quality within the food industry, methods for measuring speci c volatile organic compounds (VOCs) in a product are implemented. Such analysis is typically performed by thermal desorption (TD) with GC/MS, inevitably resulting in high sample load. In a manufacturing environment, interpretation of the complex data for the identi cation of trace-level target compounds is time consuming and often inaccurate. To address this, new software has been speci cally developed to automate this process, therefore saving time and improving accuracy. Introduction For safety and quality control purposes, there is growing demand within industry to detect and identify speci c volatile organic compounds (VOCs), e.g. in products or the surrounding environment. The food industry is a good example of this with the advent of various regulations involving product safety and quality, typically in relation to avour composition, taint and contamination. Standard VOC analyses of food samples by TD-GC/MS can yield complex chromatograms in which some compounds, particularly those at trace level, are hard to detect. Interpretation of this data using conventional library search methods is very time consuming and unlikely to generate accurate results, particularly for laboratories/ manufacturers with limited MS expertise. To address this problem, TargetView software (ALMSCO International Ltd., UK) has been developed to automate interpretation, therefore simplifying and speeding up analysis. After importing the GC/MS data le for the sample, the software interrogates the total ion chromatogram (TIC) for compounds of interest (e.g. regulatory compounds) and generates a simple post analysis report of those identi ed. TargetView processes GC/MS data using de ned target libraries of compounds as a point of reference. The number of compounds within these libraries may extend from an individual substance up to several hundred. Within complex GC/MS TIC pro les there may be signi cant compound coelution which may also include matrix effects. In an attempt to alleviate these problems, TargetView adopts a chemometric approach to data analysis. The software initially minimises background noise by dynamic background compensation (DBC). This is then followed by spectral deconvolution to identify individual components within the data, and nally, principle component analysis (PCA) highlights target compounds found in the sample by comparing the deconvolved compound spectra to those of the target library. To illustrate these processes and demonstrate the data-mining ef ciency of the software via its application within the food industry, a sample of potato crisps was analysed for the presence of speci c pyrazines. Pyrazines are VOCs that are responsible for avouring in a variety of foods. The extraction of chemicals from the crisps using a Micro- Chamber/Thermal Extractor (µ-cte ; Markes International Ltd., UK) leads to sensitive, and therefore comprehensive, VOC analysis by TD-GC/MS. Method A crushed sample (~5 g) of potato crisps was placed into one of the four chambers of the µ-cte unit (four- and six-chamber µ-cte units are available). The chambers were heated to 40 C and a purge gas of helium was applied at a ow rate of 40 ml/min for 25 minutes to allow equilibration. Air exhausting from the chamber was then collected for 10 minutes onto a 3.5 x 6.4 mm OD thermal desorption (TD) tube (Markes) containing Tenax TA as the retaining sorbent. Trapped emissions were thermally desorbed on UNITY 2 (Markes) and analysed by GC/TOF-MS. Analytical conditions TD Instrument: UNITY 2 Desorb temp: 300 C for 5 min Trap low: 0 C Trap high: 320 C Trap: General purpose trap (Tenax TA) Split: Single split 20:1
2 ANTV10 April GC Oven: Run Time: Column: Initial ow: 40 C for 2 min, then 20 C/min up to 240 C for 2 min 14 min HP-INNOWax Polyethylene Glyco 30 m x 250 µm x 0.25 µm 1.5 ml/min MS Instrument: BenchTOF-dx Transfer line temp:250 C Ion source temp: 200 C Results and discussion Report generation The GC/MS data le is imported into TargetView and the TIC processed. This results in an Excel-compatible text report, listing target compounds found within the sample. Several pyrazines were identi ed in the crisps by the software. However here, three speci c compounds (dimethyl pyrazine, ethyl methyl pyrazine and ethyl dimethyl pyrazine) were selected for reference as their concentration was very low (Figure 1). The information in the report can be sorted by compound name, retention Figure 2: GC/MS data for crisp sample showing the effect of DBC (original data shown in black, DBC data shown in blue) time, area, etc. This useful report is automatically generated and easily interpreted by a non-expert user. Implementation of DBC The initial dynamic background compensation (DBC) process is fundamental to the pro ciency of TargetView. The purpose of DBC is to suppress background ions that are not contributing towards TIC peaks, i.e. interference or noise from column bleed, air/water offset, etc. This is the rst algorithm applied to the data, and the result is a signi cantly improved baseline with enhanced compound spectral purity. This allows TargetView to process real peak data without the inclusion of interfering ions. As TargetView preserves the original data le (creating a second le for processing), the DBC-processed data can be compared to the original to observe the improvement. Figure 2 shows the effect of DBC on the TIC for the crisp sample; the black trace represents original data, and the blue represents the DBC data. The enhancement of the TIC pro le as a result of DBC-processing is clear. Figure 2 also indicates the high sample load from the TD system into the GC/MS. This is re ected in the abundance scale, which ultimately extends to 1+e8. The large concentration of some components in the sample makes identi cation of trace level compounds much more challenging; especially where co-elution is present. Deconvolution and PCA Figure 1. Example post-run report for three pyrazines found in crisp sample Subsequent to DBC, spectral deconvolution is applied to the TIC. This provides enhanced compound spectra for the principal component analysis (PCA) step. Where coelution occurs, spectral deconvolution processes the data for every scan/scan-set across the peak and assigns ions to the appropriate component. Conventional deconvolution techniques can be adversely affected by matrix effects from the sample; however the initial DBC stage of TargetView has
3 ANTV10 April alleviated this. Prior to deconvolution, attempting to identify compounds by library-searching spectra obtained from overlapping peaks would be likely to result in incorrect/unreliable matches. PCA is the nal stage of the automated TargetView process. Advanced chemometrics are applied to the deconvolved spectra to highlight characteristic ion fragmentation patterns, which are then compared to the compound spectra of the target library to determine matches. A match coef cient is calculated for each target analyte ranging from 0 1. The higher the coef cient, the more reliable the result; however, compounds with a match coef cient below a user selectable value (e.g. 0.8) can be excluded from the nal report to enhance con dence in the results. Graphical user interface Figure 4: Trace-level identi cation of three pyrazine compounds (indicated by arrows) Figure 3 shows the TargetView graphical user interface (GUI), comprising an upper window showing the DBC TIC, and a lower window showing the match coef cient plot for a speci c target compound with respect to retention time. In this example, dimethyl pyrazine has been selected from the drop-down list of target compounds. The presence of a bar in the lower window indicates that it has been identi ed and the co-ef cient (0.963) indicates a very reliable match. In order to visualise compounds found in the sample, the upper TIC displays an overlaid histogram plot (HPlot) in which compounds are represented by red bars. The HPlot can be con gured to show target hits only or all components. From this overlay, the degree of coelution can be seen. In addition, the bar height provides a representation of peak area. This is based on the summation of user-selected certain ions from within the deconvolved spectra. The area highlighted in gure 3 is enlarged in gure 4 to display the HPlot overlay for the target compounds. The location of the three speci c pyrazines can be seen; namely, dimethyl pyrazine, ethyl methyl pyrazine and ethyl dimethyl pyrazine. Note also the additional pyrazine compounds present in the crisps and identi ed by the software, these are listed in the upper left hand window of the GUI. The HPlot bar heights (relative to TIC peak height) indicate that these compounds are at very low concentration and submerged in an extremely complex sample matrix. By con guring the display to show the HPlot overlay for all components, i.e. both targets and unknowns, the degree of coelution can be seen. Figure 5 shows the location of the lowest concentration target compound (ethyl methyl pyrazine, labelled T ), which is co-eluting with three other unknown components. Figure 3: TargetView GUI (upper window shows DBC TIC, lower window shows match co-ef cient plot for dimethyl pyrazine)
4 ANTV10 April Identifying unknowns TargetView is primarily used to detect target compounds; however it can also be useful for the identi cation of unknowns within the sample. Figure 5: TargetView HPlot overlay con gured to display all components (red bars). Note the co-elution of ethyl methyl pyrazine (T) with three other compounds in the same peak. Despite the high coleution and low concentration, the match co-ef cient for this compound is very high (0.96). By using conventional search methods on the raw GC/MS data, such a compound would be impossible to reliably identify. Match con dence and NIST con rmation Within TargetView, the deconvolved (apex) spectrum for a compound can be directly compared to the library entry spectrum. Figure 6 shows an example of this for the compound dimethyl pyrazine. The sample spectrum (top window) compares very well with the library spectrum (bottom window), producing the high match value (0.963). To cross-check the validity of the result from TargetView, the sample spectrum can be searched against a commercial database, e.g. NIST. Figure 7 represents the NIST search results for the dimethyl pyrazine spectrum, which indicates a high probability, rst-hit for this compound. The high match co-ef cient derived from TargetView and the additional NIST con rmation demonstrate the datamining ef ciency of the software. The identi cation of trace level compounds that are co-eluting with much higher concentration analytes is testament to the multistep approach (i.e. DBC, deconvolution and PCA) of TargetView. Figure 8 shows the spectrum for an unknown compound coeluting with the target compound diethyl pyrazine. The relevant area of the TIC is displayed inset, which shows multiple compounds eluting within the single peak. This unknown is represented by the symbol U and diethyl pyrazine represented by the symbol T. The relative heights of the HPlot bars show a signi cantly higher concentration for the co-eluting compound U over the target compound T. By searching the spectrum of an unknown within the NIST database it may be possible to identify the substance. Figure 9 represents the NIST analysis of the unknown component U spectrum. A strong match was found meaning the compound was identi ed as dimethyl styrene with high con dence. Figure 6: Comparison of sample and target spectra for dimethyl pyrazine Figure 7: Cross-searching deconvolved sample spectrum for dimethyl pyrazine against NIST database con rms dimethyl pyrazine
5 ANTV10 April Figure 8: Spectrum of unknown compound U1. Inset: HPlot overlay of target (T) and unknown compound (U). Conclusions The analysis of food products using the µ-cte and TD-GC/TOF-MS generates a high load sample, resulting in a complex GC/MS TIC pro le. The identi cation of trace-level targets within this convoluted matrix would not be possible using conventional library searching techniques. In this application, the spectral deconvolution and advanced chemometrics of TargetView have resulted in the successful identi cation of trace-level pyrazines. This is a clear demonstration of the intensive datamining capabilities afforded by the software. In addition, unknown compounds may also be identi ed if necessary. With the advent of product quality and safety regulations requiring the monitoring of speci c VOCs, TargetView is an ef cient software tool for users with limited MS expertise. This translates into increased productivity, saving time and ultimately cost in the VOC analysis of a product. Figure 9. NIST identi cation of unknown component (U) co-eluting with target TargetView has many potential applications including food, avour and fragrance analysis, materials emissions testing, air toxics detection, etc.
Application of TargetView software in the fragrance industry: Accurate identi cation of allergens with fast GC
Application Note: ANTV12 Application of TargetView software in the fragrance industry: Accurate identi cation of allergens with fast GC Introduction The need to screen consumer products for speci c organic
More informationEnhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference
Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference Abstract The advantages of mass spectrometry (MS) in combination with gas
More informationWHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS. HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE
WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE Body text is 11 pt Cynthia Georgia Liu, with 1.5 Ph.D., line spacing. Paul Dreier
More informationThe Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port
APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Authors: Andrew Tipler Sheila Eletto PerkinElmer, Inc. Shelton, CT The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory
More informationSeries 2. Continuous monitoring of trace chemical vapours
Series 2 TT24-7 Continuous monitoring of trace chemical vapours Series 2 TT24-7 TT24-7 Series 2 Continuous monitoring of trace chemical vapours The TT24-7 Series 2 is an advanced thermal desorption (TD)
More informationPesticide Analysis by Mass Spectrometry
Pesticide Analysis by Mass Spectrometry Purpose: The purpose of this assignment is to introduce concepts of mass spectrometry (MS) as they pertain to the qualitative and quantitative analysis of organochlorine
More informationGENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1
GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert, Michel Lhermitte, Frederic Grisel Laboratoire de Toxicologie & Génopathologie, CHRU Lille, France Waters Corporation, Guyancourt,
More informationExpectations for GC-MS Lab
Expectations for GC-MS Lab Since this is the first year for GC-MS to be used in Dr. Lamp s CHEM 322, the lab experiment is somewhat unstructured. As you move through the two weeks, I expect that you will
More informationBackground Information
1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software
More informationMulti-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible
Multi-Shot Pyrolyzer EGA/PY-3030D Flexible Versatile Reproducible Why Evolved Gas Analysis? Why Pyrolysis? Today, analytical pyrolysis encompasses much more than simple flash pyrolysis of polymeric materials.
More informationMassHunter for Agilent GC/MS & GC/MS/MS
MassHunter for Agilent GC/MS & GC/MS/MS Next Generation Data Analysis Software Presented by : Terry Harper GC/MS Product Specialist 1 Outline of Topics Topic 1: Introduction to MassHunter Topic 2: Data
More informationIndoor Air Comfort Test Report
Knauf Insulation SPRL Rue de Maestricht, 95 B-4600 Vise Belgium Indoor Air Comfort Test Report 1 Sample Information Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark voc@eurofins.com www.eurofins.com/voc-testing
More informationAlignment and Preprocessing for Data Analysis
Alignment and Preprocessing for Data Analysis Preprocessing tools for chromatography Basics of alignment GC FID (D) data and issues PCA F Ratios GC MS (D) data and issues PCA F Ratios PARAFAC Piecewise
More informationAnalysis of Liquid Samples on the Agilent GC-MS
Analysis of Liquid Samples on the Agilent GC-MS I. Sample Preparation A. Solvent selection. 1. Boiling point. Low boiling solvents (i.e. b.p. < 30 o C) may be problematic. High boiling solvents (b.p. >
More informationUsing NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012.
Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012 Introduction Screen captures in this document were taken from MassHunter B.05.00
More informationRAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH
RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH Cristiana C. Leandro 1, Peter Hancock 1, Christian Soulier 2, Françoise Aime 2 1 Waters Corporation, Manchester,
More informationTechnical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database
C146-E175A Technical Report Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database Hitoshi Tsuchihashi 1 Abstract: A sample consisting
More informationMultiQuant Software 2.0 for Targeted Protein / Peptide Quantification
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification Gold Standard for Quantitative Data Processing Because of the sensitivity, selectivity, speed and throughput at which MRM assays can
More informationAnalysis of Phthalate Esters in Children's Toys Using GC-MS
C146-E152 Analysis of Phthalate Esters in Children's Toys Using GC-MS GC/MS Technical Report No.4 Yuki Sakamoto, Katsuhiro Nakagawa, Haruhiko Miyagawa Abstract As of February 29, the US Consumer Product
More informationFast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD
Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD Application Note Environmental Author Xiaohua Li Agilent Technologies (Shanghai) Co., Ltd. 412 Ying Lun
More informationAppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT
AppNote 6/2003 Analysis of Flavors using a Mass Spectral Based Chemical Sensor Vanessa R. Kinton Gerstel, Inc., 701 Digital Drive, Suite J, Linthicum, MD 21090, USA Kevin L. Goodner USDA, Citrus & Subtropical
More informationSTANDARD OPERATING PROCEDURES
PAGE: 1 of 33 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS
More informationHow To Analyze Pesticide Levels In Lemon Oil
AppNote 9/2006 Target GC-MS Analysis using Accelerated Column Heating and Interactive Deconvolution Software Albert Robbat Tufts University, Chemistry Department, Medford, MA 02155, USA Andreas Hoffmann
More informationMass Frontier 7.0 Quick Start Guide
Mass Frontier 7.0 Quick Start Guide The topics in this guide briefly step you through key features of the Mass Frontier application. Editing a Structure Working with Spectral Trees Building a Library Predicting
More informationTuning & Mass Calibration
Tuning & Mass Calibration 1 1 The Sample List Sample List Name Project Name 2 The sample list is the top level screen in the TurboMass Gold Software. Data storage is set up in PROJECT files and within
More informationThe First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies
The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies INEF Penn State Conference 2013 Albert Robbat, Jr. and Patrick Antle Tufts University, Chemistry
More informationAccurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances
Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances TripleTOF 5600 + LC/MS/MS System with MasterView Software Adrian M. Taylor AB Sciex Concord, Ontario (Canada) Overview
More informationThermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software
Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software Mark Belmont and Alexander N. Semyonov, Thermo Fisher Scientific, Austin, TX, USA Ming Gu, Cerno Bioscience,
More informationGas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.
Gas Chromatography Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Samples in 10mL sealed glass vials were placed in the MPS-2
More informationApplication of Structure-Based LC/MS Database Management for Forensic Analysis
Cozette M. Cuppett and Michael P. Balogh Waters Corporation, Milford, MA USA Antony Williams, Vitaly Lashin and Ilya Troisky Advanced Chemistry Development, Toronto, ntario, Canada verview Application
More informationTHERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles
THERMAL DESORPTION Introduction and Principles Thermal Desorption Thermal desorption is a simple extension of the technique of gas chromatography (GC) It involves the use of heat and a flow of inert gas
More informationMetabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes
Metabolomics Software Tools Xiuxia Du, Paul Benton, Stephen Barnes Outline 2 Introduction Software Tools for LC-MS metabolomics Software Tools for GC-MS metabolomics Software Tools for Statistical Analysis
More informationAnalysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS-1603. No. SSI-GCMS-1603. Shilpi Chopra, Ph.D.
Gas Chromatograph Mass Spectrometer No. GCMS-1603 Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS Shilpi Chopra, Ph.D. Introduction Organophosphorus (OP) pesticides are a class
More informationBuilding Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview
Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview Authors Xiaofei Ping Agilent Technologies (Shanghai) Co Ltd 412 Yinglun Road, Shanghai, 200131 P.R. China
More informationMarkerView Software 1.2.1 for Metabolomic and Biomarker Profiling Analysis
MarkerView Software 1.2.1 for Metabolomic and Biomarker Profiling Analysis Overview MarkerView software is a novel program designed for metabolomics applications and biomarker profiling workflows 1. Using
More information23 The Thermal Conductivity Detector
23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing
More informationChemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample
More informationMEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process
- Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples
More informationSeries 2. Air Server. Options for UNITY 2. A robust, cryogen-free solution for round-the-clock on-line air monitoring
Series 2 Air Server Options for UNITY 2 A robust, cryogen-free solution for round-the-clock on-line air monitoring Series 2 Air Server Three- and eight-channel options for UNITY offering round-the-clock
More informationThermo Scientific SIEVE Software for Differential Expression Analysis
m a s s s p e c t r o m e t r y Thermo Scientific SIEVE Software for Differential Expression Analysis Automated, label-free, semi-quantitative analysis of proteins, peptides, and metabolites based on comparisons
More information1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.
Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative
More informationChemical Analysis of Chardonnay Wines: Identification and Analysis of Important Aroma Compounds
Chemical Analysis of Chardonnay Wines: Identification and Analysis of Important Aroma Compounds ABSTRACT Chardonnay wines from leading world producers were selected for analysis and comparison of volatile
More informationDetermination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS
Application Note No. 051 Determination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS by P Jüngel ¹), J Wittenzellner ²) and E Melcher ¹) ¹) Federal Research Centre
More informationApplication Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation
Application Note Determination of Nitrite and Nitrate in Fruit Juices by UV Detection Category Food Matrix Fruit Juice Method HPLC Keywords Ion pair chromatography, fruit juice, inorganic anions AZURA
More informationAnalyzing Small Molecules by EI and GC-MS. July 2014
Analyzing Small Molecules by EI and GC-MS July 2014 Samples Appropriate for GC-MS Volatile and semi-volatile organic compounds Rule of thumb,
More informationGriffin 460 Mobile GC/MS Analysis of Designer Drugs, Including Synthetic Cannabis & Bath Salts, Utilizing Prepless Sample Introduction (PSI) Probe
WHITE PAPER Griffin 460 Mobile GC/MS Analysis of Designer Drugs, Including Synthetic Cannabis & Bath Salts, Utilizing Prepless Sample Introduction (PSI) Probe Aaron K. Thompson, MS, Steven B. Shaull, BS
More informationSetting up a Quantitative Analysis MS ChemStation
Setting up a Quantitative Analysis MS ChemStation Getting Ready 1. Use the tutorial section "Quant Reports" on the MSD Reference Collection CD-ROM that came with your ChemStation software. 2. Know what
More informationFractional Distillation and Gas Chromatography
Fractional Distillation and Gas Chromatography Background Distillation The previous lab used distillation to separate a mixture of hexane and toluene based on a difference in boiling points. Hexane boils
More informationFORENSIC TOXICOLOGY LABORATORY OFFICE OF CHIEF MEDICAL EXAMINER CITY OF NEW YORK. VOLATILES ANALYSIS by GCMS HEADSPACE ANALYSIS
FORENSIC TOXICOLOGY LABORATORY OFFICE OF CHIEF MEDICAL EXAMINER CITY OF NEW YORK VOLATILES ANALYSIS by GCMS HEADSPACE ANALYSIS PRINCIPLE This method confirms the identity of volatile compounds in biological
More informationHow To Use Gc-Ms
The CHROMacademy Essential Guide Understanding GC-MS Analysis Part 1 Speakers John Hinshaw GC Dept. Dean CHROMacademy Tony Taylor Technical Director Crawford Scientific Moderator M ( g ) e M ( g ) 2e Peter
More informationTracer Detection Systems
Tracer Detection Systems WASSON ECE Engineered Solutions, Guaranteed Results. Wasson-ECE Tracer Analysis System The industry standard for low level perfluoronated tracer analysis. Tracer tagging technology
More informationIn-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates Using the Explore Workflow on the AB SCIEX TripleTOF 5600 System A major challenge in proteomics
More informationThe Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring
The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring Delivering up to 2500 MRM Transitions per LC Run Christie Hunter 1, Brigitte Simons 2 1 AB SCIEX,
More informationA Streamlined Workflow for Untargeted Metabolomics
A Streamlined Workflow for Untargeted Metabolomics Employing XCMS plus, a Simultaneous Data Processing and Metabolite Identification Software Package for Rapid Untargeted Metabolite Screening Baljit K.
More informationDetermination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS
Determination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS Thorsten Bernsmann, Peter Fürst Chemical and Veterinary Analytical Institute Münsterland-Emscher-Lippe Joseph-König-Str. 40,
More informationChemical Profiling and Differential Analysis of Whiskies Using Orbitrap GC-MS
Chemical Profiling and Differential Analysis of Whiskies Using Orbitrap GC-MS Dominic Roberts, 1 Jana Hajslova, 2 Jana Pulkrabova, 2 and Paul Silcock 1 1 Thermo Fisher Scientific, Runcorn, UK 2 University
More informationIncreasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays
Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays Scheduled MRM HR Workflow on the TripleTOF Systems Jenny Albanese, Christie Hunter AB SCIEX, USA Targeted quantitative
More informationWaters Core Chromatography Training (2 Days)
2015 Page 2 Waters Core Chromatography Training (2 Days) The learning objective of this two day course is to teach the user core chromatography, system and software fundamentals in an outcomes based approach.
More informationTechNote 3/2002. The Use of Different PTV Inlet Liner Types for Trapping Alkanes, Aromatics and Oxygenated Compounds During Thermal Desorption
TechNote 3/22 The Use of Different PTV Inlet Liner Types for Trapping Alkanes, Aromatics and Oxygenated Compounds During Thermal Desorption Bita Kolahgar Gerstel GmbH & Co. KG, Eberhard-Gerstel-Platz 1,
More informationAnalysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection
Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection Evelyn Goh, Antonietta Gledhill Waters Pacific, Singapore, Waters Corporation, Manchester, UK A P P L I C AT
More informationThe Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.
The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. Mark Crawford Single Presenter Name Abstract With the recent decline in hive bee populations this year the investigation of acaricides
More informationAMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
More informationSimultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF
Simultaneous qualitative and quantitative analysis using the Agilent 654 Accurate-Mass Q-TOF Technical Overview Authors Pat Perkins Anabel Fandino Lester Taylor Agilent Technologies, Inc. Santa Clara,
More informationA VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water
A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water Sjaak de Koning 1, Mark van Lieshout 2, Hans-Gerd Janssen 2 and Wil van Egmond 1 1 ATAS, De Run 4334, PO Box
More informationHow To Prevent Corrosion In A Steam Electric Power Plant
Keeping corrosion at bay Analysis in ultra-supercritical power plants Corrosion is the natural enemy of steam-electric power plants, eating away at pipes, turbine blades, and rotors. The lack of a separation
More informationOverview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System
Investigating the use of the AB SCIEX TripleTOF 4600 LC/MS/MS System for High Throughput Screening of Synthetic Cannabinoids/Metabolites in Human Urine AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS
More informationMass Frontier Version 7.0
Mass Frontier Version 7.0 User Guide XCALI-97349 Revision A February 2011 2011 Thermo Fisher Scientific Inc. All rights reserved. Mass Frontier, Mass Frontier Server Manager, Fragmentation Library, Spectral
More informationStep-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry BY GHULAM A. SHABIR Introduction Methods Validation: Establishing documented evidence that provides a high
More informationLearning Objectives:
Proteomics Methodology for LC-MS/MS Data Analysis Methodology for LC-MS/MS Data Analysis Peptide mass spectrum data of individual protein obtained from LC-MS/MS has to be analyzed for identification of
More informationIntegrated Data Mining Strategy for Effective Metabolomic Data Analysis
The First International Symposium on Optimization and Systems Biology (OSB 07) Beijing, China, August 8 10, 2007 Copyright 2007 ORSC & APORC pp. 45 51 Integrated Data Mining Strategy for Effective Metabolomic
More informationINTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS
AxION iqt GC/MS/MS INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE IDENTIFY WHAT YOU RE LOOKING FOR (AND EVEN WHAT YOU RE NOT) The GC/MS/MS Solution for the Work You Do The ideal solution for industrial,
More informationNew drugs of abuse? A case study on Phenazepam & Methoxetamine
New drugs of abuse? A case study on Phenazepam & Methoxetamine Presenter: Nadia Wong Co authors: Dr Yao Yi Ju & Alex Low Xuan Kai Analytical Toxicology Laboratory Clinical & Forensic Toxicology Unit Applied
More informationSelective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS
Application Note: 446 Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS Jonathan McNally and Michael Belford, Thermo Fisher Scientific, San Jose, CA James Kapron, Thermo Fisher Scientific,
More informationAB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs
AB SCIEX TOF/TOF 4800 PLUS SYSTEM Cost effective flexibility for your core needs AB SCIEX TOF/TOF 4800 PLUS SYSTEM It s just what you expect from the industry leader. The AB SCIEX 4800 Plus MALDI TOF/TOF
More informationSCION SQ Series GC-MS
SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative
More informationA Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015
A Navigation through the Tracefinder Software Structure and Workflow Options Frans Schoutsen Pesticide Symposium Prague 27 April 2015 Kings day in The Netherlands 1 Index Introduction Acquisition, Method
More informationApplication Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method
Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method Introduction During the last decade, the complexity of samples
More informationApplication Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M
Bruker Daltonics Application Note # MS- Fast n-site Identification of Drugs with the mobile GC/MS system E²M For the detection of drugs a couple of quick tests are available which were used by the police
More informationAccelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform
Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform Remco Swart Pittcon March 8-12, 2015 1 The world leader in serving science Outline Thermo Scientific Vanquish UHPLC
More informationß-CYCLODEXTRIN SYNONYMS
ß-CYCLODEXTRIN Prepared at the 44th JECFA (1995), published in FNP 52 Add 3 (1995) superseding specifications prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications
More informationDetermination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and
More informationIncreasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening
Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening Application Note Forensics Author Erin Shonsey Director of Research Alabama Department of Forensic Science Abstract
More informationDetermination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*
Method 552.1 Revision 1.0 Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD* UCT Products: EUQAX156 (quaternary amine with Cl - counter ion, 6 ml cartridge)** CLTTP050 (CLEAN-THRU
More informationTurning HTE Agilent LC/MS Data to Knowledge in 1hr
With permission Reaction Analytics Inc. 2011 Page 1 Turning HTE Agilent LC/MS Data to Knowledge in 1hr Neal Sach With permission Reaction Analytics Inc. 2011 Page 2 Contents Acquiring Data Fast demo method
More informationVALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)
INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED TRIPARTITE GUIDELINE VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY
More informationSplit / Splitless Injection for Capillary GC
Split / Splitless Injection for Capillary GC Speakers John V Hinshaw CHROMacademy GC Dean GC Connections editor Moderator Tony Taylor CHROMacademy Trainer Technical Director, Crawford Scientific Dave Walsh
More informationExtraction of Cannabinoids in Marijuana and Edibles by QuEChERS
Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS UCT Part Numbers: ECQUEU750CT-MP - QuEChERS, Mylar packs containing 4 g magnesium sulfate, 1 g sodium chloride, 0.5 g sodium citrate dibasic
More informationNew Jersey Department of Environmental Protection Division of Remediation Management Response Site Remediation Program
New Jersey Department of Environmental Protection Division of Remediation Management Response Site Remediation Program NJDEP- SRP Low Level USEPA TO-15 Method (NJDEP-LLTO-15-3/2007) March 2007 March 2009
More informationA High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS
A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS AB SCIEX QTRAP 4500 LC/MS/MS System and Gerstel, Inc. MultiPurpose Sampler
More informationIntroduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?
Increasing Chemist Productivity in an Open-Access Environment Ryan Sasaki, Graham A. McGibbon, Steve Hayward Featuring ACD/Spectrus Processor and Aldrich Library for ACD/Labs Advanced Chemistry Development,
More informationPurification of reaction mixtures using flash chromatography.
Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?
More informationBenzo[a]pyrene Method Development
Benzo[a]pyrene Method Development Dr Michael Intorp CORESTA Cooperation Center for Scientific Research Relative to Tobacco FDA Center for Tobacco Products Scientific Workshop Tobacco Product Analysis 30
More informationTutorial 9: SWATH data analysis in Skyline
Tutorial 9: SWATH data analysis in Skyline In this tutorial we will learn how to perform targeted post-acquisition analysis for protein identification and quantitation using a data-independent dataset
More informationPaper Chromatography: Separation and Identification of Five Metal Cations
Paper Chromatography: Separation and Identification of Five Metal Cations Objectives Known and unknown solutions of the metal ions Ag +, Fe 3+, Co 2+, Cu 2+ and Hg 2+ will be analyzed using paper chromatography.
More informationQuantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay
PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird
More informationGC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits
Issue Implementation Page 1 of 7 GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits Scope and Application This method will determine the level of vanillin and ethyl vanillin in distilled
More informationSTANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA 94305-5080
Training on the ZQ Open access MS Questions? Contact Dr. Allis Chien allis@stanford.edu 650-723-0710 0710 STANFORD UNIVERSITY MASS SPECTROMETRY STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD
More information