Residential & Commercial Use Of DC Power



Similar documents
380VDC Data Center At Duke Energy

DC powered data centers in the world

Edison s Data Center: 380Vdc brings Reliability and Efficiency to Sustainable Data Centers

EGSTON Standard E2xFxWx 12W

400V DC Microgrid Small Scale Demo System for Telecom and Datacom Applications

Qualitative Analysis of Power Distribution Configurations for Data Centers

Duke Energy - EPRI DC Powered Data Center Demonstration Executive Summary

Electrical Systems. <Presenter>

How To Convert A Power Grid To A Direct Current (Dc) Power System

Cisco Nexus 7000 Series Power Supply Modules

Wireless Networks and Power Quality

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Edison Redux. 380 Vdc Brings Reliability and Efficiency to Sustainable Data Centers. By Guy AlLee and William Tschudi

Intelligent Power Distribution in the Data Center

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

DC MICROGRIDS A SOLAR BACK TO THE FUTURE

BB800 Off-Grid Solar System

Brian T. Patterson - Chairman. Governing Member, EMerge Alliance General Manager, Armstrong World Industries

NetSure DC Power Solutions with esure High-Efficiency Technology

ECCN Exclusive Product Webinar Electric Vehicle Supply Equipment. Agenda. Presenter Introduction

Server Technology, Inc.

France Telecom Energy consumption, HVDC, cooling improvement

Calculating Total Power Requirements for Data Centers

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

High-Efficiency AC Power Distribution for Data Centers

Public Overview of the EMerge Alliance Data/Telecom Center Standard Version 1.0

MPR-Systems. Mini Power Racks 1200 W W

Power Distribution Considerations for Data Center Racks

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

What s a Kilowatt-hour Good For?

MAJORSINE Power Inverter

Phase Modular Finally the benefits of Modular ups are for all

SolarMax P series The power package for residential solar plants

NetSure DC Power Solutions with esure High-Efficiency Technology. DC Power for Business-Critical Continuity TM

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

High-voltage DC distribution is key to increased system efficiency and renewable-energy opportunities

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Intel Server System S7000FC4UR

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

HP ProLiant power supply technology

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310

Power Supply Specifications

Datacenter Design Issues

BC Pro UPS System Standby UPS System

NIST Coordination and Acceleration of Smart Grid Standards. Tom Nelson National Institute of Standards and Technology 8 December, 2010

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

DC Microgrids. Christine Chan CSE 291 5/29/2013

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Uninterruptible Power Supply

Infinity C DC to DC Power System

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Integration of a 400W ac dc power supply into a closed system relying only on natural convection cooling

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Handheld portable appliance testers

TORKEL 820 Battery Load Unit

DC Power Solutions Overview. DC Power Solutions for EVERY Network Application.

Server Technology Inc.

RIELLO ELETTRONICA. Master HP

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

Ringing at the Door. Boiling an egg. Moving by car. Flows of solar energy. There is no energy crisis. How to boil an egg?

ACTURA V DC, 3-40 kw, A. The Regional DC power system with Global Muscle

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

Energy Storage System Performance Testing

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Specifications for the Gateway M1300 Tablet PC

High-density modular data center making cloud easier. Frank Zheng Huawei

Inverter / Charger Installation General Operations and AC and DC Connections

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Distributing Power to Blade Servers

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

Definition AC Power Distribution

Future grid infrastructure Field tests of LVDC distribution

Models HP 230W Smart AC Adapter. HP 40W Smart AC Adapter (H5W93AA) HP 65W Smart AC Adapter (ED494AA) HP 90W Smart AC Adapter (ED495AA)

Electric Vehicle Charging Solutions

/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready

415V DISTRIBUTION FOR GREEN DATA CENTERS

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

POWER YOUR TELECOM SITE WITH OLYMPIAN Hybrid Power for Telecom Applications Solar Photovoltaic Wind Diesel Battery

Photovoltaic System Overcurrent Protection

Opportunity of Energy Saving in electrical path is lesser as compared to other areas

A project to optimise quality and energy efficiency must include metering

415V DISTRIBUTION FOR GREEN DATA CENTERS

QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

Transcription:

Residential & Commercial Use Of DC Power Dennis P. Symanski Senior Project Manager NEMA, UL & NFPA Low Voltage Direct Current Workshop 08APR2011 Arlington, VA

From Dept of Energy Secretary Steven Chu As Energy Secretary Steven Chu has noted, America cannot build a 21st Century energy economy with a mid- 20th Century electricity system. Transforming the current grid into a dynamic, resilient, and adaptable Smart Grid will be one of the biggest technological challenges of our times. The rewards, however, may be dramatic, enabling consumers to better control their electricity use, integrating the next generation of plug-in electric vehicles, increasing efficiency, and better harnessing renewable energy. Source: Department of Energy, Communications Requirement Of Smart Grid Technologies, October 5, 2010 2

Smart Grid to Smart Buildings Source: EMerge Alliance Overview 3

DC Microgrids Throughout Buildings 24 VDC 380 VDC 380 VDC 24 & 380 VDC Source: EMerge Alliance Overview 4

EMerge Alliance Standard 24VDC Ceiling View INFRASTRUCTURE: Ceiling Walls Furniture Floors 5

Who Is EMerge? Manufacturers Building Owners Technology Leaders Contractors/Builders Architects Engineers National Labs Codes & Standards Groups 6

Data Center Types, Sizes and Numbers Type Server Closet Server Room Localized Data Center Mid tier Data Center Enterprise Class Data Center Scope Secondary computer location, often outside of IT control, or may be a primary site for a small business Secondary computer location, under IT control, or may be a primary site for a small business Primary or secondary computer location, under IT control Primary computing location, under IT control Primary computing location, under IT control Power/cooling Standard room air conditioning, no UPS Upgraded room air conditioning, single UPS Maintained at 17 C; some power and cooling redundancy Maintained at 17 C; some power and cooling redundancy Maintained at 17 C; at least N+1 power & cooling redundancy Sq ft <200sq ft <500sq ft <1,000sq ft <5,000sq ft >5,000 sq ft US data centers (2009 est) Total Servers (2009 est) Average servers per location 1,345,741 = 51.8% 1,170,399 = 45.1% 64,229 = 2.5% 9,758 = 0.4% 7,006 = 0.3% 2,135,538 = 17% 3,057,834 = 24% 2,107,592 = 16% 1,869,595 = 15% 3,604,678 = 28% 2 3 32 192 515 7

Data Center Type and Server Population 0.7% of data centers (Enterprise & Mid-tier) contain 43% of all servers (Amazon/Apple/Facebook/Google/Yahoo) They have staffs of internal electrical & mechanical engineers to design & construct efficient data centers --- 99.3% of data centers (more than 2.5 million of them) contain 57% of all servers (Hospitals/Hotels/Universities/Utilities/Banks /City Halls/Supermarkets/Chain Stores) These data centers operators struggle with heat/space/power problems without much internal expertise 8

380VDC Data Center Activity Involved With Multiple 380VDC Demos Universities Electric Utilities Telecom Industry Harmonizing Multiple 380VDC Spec Efforts DC Power Partners Joining EMerge Alliance European Telecommunications Standards Institute International Electrotechnical Commission (SG4) Working With Many Manufacturers IT Equipment As Well As Facility Equipment 9

Worldwide ~380VDC Demos US Intel Corp. 400 VDC France Telecom 350 VDC Sweden UPN AB. 350 /380VDC Japan NTT Group 380/400 VDC US UCSD 380 VDC Japan Other Demos 300 350 VDC US DukeEnergy 380 VDC New Zealand Telecom NZ 220 VDC Source: NTT FACILITIES, INC. 10

Duke Energy 380VDC Data Center Demo HP Servers IBM Servers EMC Storage Arrays Delta Rectifiers StarLine Busway Dranetz-BMI Metering 11

Duke Energy Data Center Set-Up 12

Delta Products DC UPS Modular design Hot swappable control module 20kW per power module 80kW 120kW 160kW 280kW Redundancy Configuration Facility Configuration Row Configuration + Batteries Batteries DC UPS Battery Room Servers Clusters 60+20kW DC UPS Servers 60+20kW DC UPS 13

Delta Products Rectifier Module Spec Power Module capacity 20KW. Input voltage: 480/277V, 400/230V, 380/220V Input range: +15%~ 20%of Nominal Voltage. Input power factor >0.99. Current Total Harmonic Distortion <5%. Output voltage 350/380/400Vdc (Nominal). Current balance accuracy < 3%. Output Voltage regulation < 1% Output short current limit: 75A. AC DC efficiency : 96%. Fully DSP based digital control. Delta patented topology for 3 phase buck boost PFC. Swappable power module design. Dimension: 129(H) x 219(W) x 700(D) mm. Weight: 16.1 Kg 14

Why 380VDC? Sweet Spot 1000 1500 IEC 900 BS (U.K.) High Long DC Voltage 800 600 380 750 Ordinance (JPN) 600 NEC(U.S.) 450 428 (192cell) 374 (168cell) 321 (144cell) 300 575 [to 48] Validus 380 US DC Demo 300 NEDO PJ. (Sendai) Server PS 405 350 320 Operating bulk - voltage 373(U.K.) 354(EU) 324V (US 311(JPN) Distribution efficiency Cable Distance 420 380 260 200 Low Short 0 Law, Regulation, Code, and Stds. Distr. Gen. Telecom (Number of Cells) Demos (Reference) Rating voltage of parts and elements AC ICT input voltages ( Peak ) Benefit of HVDC system ETSI Std. (draft) Edited from source: NTT FACILITIES, INC. 15

380VDC vs ITI(CBEMA) VAC Operating Ranges Voltage Tolerance Envelope for traditional AC powered computers (left) New, DC version of curve, developed by EPRI with NTT and PSL (right) 16

380VDC Power Distribution NOTE: All loads are to be connected between L(+) and L(-). PE is not a power conductor. 17

Easier Integration Of Renewables Reference to Nextek Power Systems US Patent 7,872,375 18JAN2011 18

Benefits Summary Of 380VDC Higher Reliability Fewer Conversions/Fewer Points Of Failure Higher Efficiency Higher Efficiency Power Supplies & UPS No PDU Transformer Needed Smaller Size Better Power Quality Easier Integration Of Renewable Energy Easier Integration of Energy Storage 19

Other DC Applications 380VDC Uses Telecom Central Offices (Operating Today At 48VDC) Variable Speed Drives (Washers/Dryers/Air Cond) Other Home Appliances (Stoves/Ovens) Rapid Charger For Plug-in Electric Vehicles 24VDC Uses Lighting Consumer Electronics (TVs, PCs, Projectors) EMerge Alliance Members Working On Both Voltages 20

DC Challenges Standardizing on DC Voltages 24VDC & 380VDC looking like leading candidates Safety Agency Approval/Listing (e.g. UL) DC & AC Products Both Need These Approvals Paradigm Shift Back To Some Of Thomas Edison s DC Ideas We Are Used To The AC World Today Vendor Selection Many AC Vendors To Choose From Fewer DC Vendors Available --- At Least For Now 21

DC-Powered Home - Fantasy or Future Reality? 22

DC-Powered Home - Fantasy or Future Reality? My own home already has many DC-Powered products with external power supplies: My Laptop Computer (20 V 4.5 A) My Cell Phone (5 V 550 ma) My Wife s Cell Phone (5 V 350 ma) 4 Wireless Phones (6.5 V 500 ma) Wireless Internet Router (5 V 2.5 A) 2 Cable Modems (12 V 750 ma) Electric Razor (12 V 400 ma) Powered USB Port (5 V 3.8 A) Battery Operated Vacuum Cleaner (10 V 250 ma) 23

DC-Powered Home - Fantasy or Future Reality? My own home already has many DC-Powered products with internal power supplies: BlueRay DVD Player (26 W) 2 Cable Set-Top Boxes (4.2 A) Bose Home Theatre System (300 W) 54 Plasma TV (465 W) 36 LCD TV (175 W) PC Mini-Tower (6 A) 19 LCD Display (1.2 A) 24

DC-Powered Home - Fantasy or Future Reality? My own home also has many BIG AC-Powered loads: Microwave Oven (240 V 8.3 kw) Dishwasher (120 V 11 A) Toaster (120 V 1050 W) Coffee Pot (120 V 1100 W) Clothes Washer (120 V 7 A) Electric Clothes Drier (240 V 5600 W) Refrigerator (120 V 8.3 A) Electric Cook-top (240 V 8.8 kw) Electric Oven (240 V 3600 W) 25

Together Shaping the Future of Electricity 26