Power Supply Specifications
|
|
|
- Dwayne Sparks
- 9 years ago
- Views:
Transcription
1 APPENDIXA This appendix describes the Catalyst 6500 series power supplies and provides their specifications. This appendix contains the following sections: Power Supply Compatibility Matrix, page A W AC-Input and DC-Input Power Supplies, page A W AC-Input Power Supply, page A W AC-Input and DC-Input Power Supplies, page A W AC-Input Power Supply, page A W AC-Input and DC-Input Power Supplies, page A W AC-Input and DC-Input Power Supplies, page A W AC-Input Power Supply, page A W AC-Input and DC-Input Power Supplies, page A W AC-Input and DC-Input Power Supplies, page A W AC-Input Power Supply, page A-54 AC Power Cord Illustrations, page A-63 Power Supply Redundancy, page A-73 Table A-1 lists the currently available Catalyst 6500 series switch power supplies and the power supply description location. Table A-1 Catalyst 6500 Series Power Supplies Power Supply Rating AC-Input Model Product Number DC-Input Model Product Number 950 W 1 PWR-950-AC PWR-950-DC 1000 W WS-CAC-1000W Not Available 1300 W WS-CAC-1300W WS-CDC-1300W 1400 W 1 PWR-1400-AC Not Available 2500 W WS-CAC-2500W WS-CDC-2500W 2700 W 2 PWR-2700-AC/4 PWR-2700-DC/ W WS-CAC-3000W Not Available A-1
2 Power Supply Compatibility Matrix Table A-1 Catalyst 6500 Series Power Supplies (continued) Power Supply Rating AC-Input Model Product Number 4000 W WS-CAC-4000W-US1 WS-CAC-4000W-INT PWR-4000-DC 6000 W WS-CAC-6000W PWR-6000-DC 8700 W WS-CAC-8700W-E Not Available 1. For use with the Catalyst 6503 and Catalyst 6503-E switches only. 2. For use with the Catalyst 6504-E switch only. DC-Input Model Product Number Note The Catalyst 6500 series switches allow you to mix AC-input and DC-input power supplies in the same chassis. Note Many telco organizations require a 48 VDC power supply to accommodate their power distribution systems. From an operational perspective, the DC-input power supply has the same characteristics as the AC-input version. Power Supply Compatibility Matrix Table A-2 lists the compatibility of the power supplies with the Catalyst 6500 switch chassis. Table A-2 Catalyst 6500 Series Switch Supported Power Supply Configurations Platform Supported Power Supplies Chassis/Power Supply Restrictions Catalyst W AC-input and DC-input The 950 W AC-input power 1400 W AC-input supply requires a PEM-15A-AC Power Entry Module (PEM). Catalyst 6503-E 950 W AC-input and DC-input 1400 W AC-input The 1400 W AC-input power supply requires a PEM-20A-AC+ Power Entry Module (PEM). The 950 W AC-input power supply requires a PEM-15A-AC Power Entry Module (PEM). The 1400 W AC-input power supply requires a PEM-20A-AC+ Power Entry Module (PEM). Catalyst 6504-E 2700 W AC-input and DC-input No restrictions A-2
3 Power Supply Compatibility Matrix Table A-2 Catalyst 6500 Series Switch Supported Power Supply Configurations (continued) Platform Supported Power Supplies Chassis/Power Supply Restrictions Catalyst W AC-input The 6000 W AC-input, 6000 W 1300 W AC-input and DC-input DC-input, and the 8700 W AC-input power supplies are limited to 2500 W AC-input and DC-input 4000 W when they are installed in 3000 W AC-input the Catalyst 6506 switch chassis W AC-input and DC-input 6000 W AC-input and DC-input 8700 W AC-input Catalyst 6506-E 2500 W AC-input and DC-input 3000 W AC-input 4000 W AC-input and DC-input 6000 W AC-input and DC-input 8700 W AC-input Catalyst W AC-input 1300 W AC-input, and DC-input 2500 W AC-input and DC-input 3000 W AC-input 4000 W AC-input and DC-input 6000 W AC-input and DC-input 8700 W AC-input Catalyst 6509-E 2500 W AC-input and DC-input 3000 W AC-input 4000 W AC-input and DC-input 6000 W AC-input and DC-input 8700 W AC-input Catalyst 6509-NEB 1000 W AC-input 1300 W AC-input and DC-input 2500 W AC-input and DC-input 3000 W AC-input 4000 W AC-input and DC-input 6000 W AC-input and DC-input 8700 W AC-input No restrictions. The 6000 W AC-input, 6000 W DC-input, and the 8700 W AC-input power supplies are limited to 4000 W when they are installed in the Catalyst 6509 switch chassis. No restrictions. The 6000 W AC-input, 6000 W DC-input, and the 8700 W AC-input power supplies are limited to 4000 W when they are installed in the Catalyst 6509-NEB switch chassis. A-3
4 Power Supply Compatibility Matrix Table A-2 Catalyst 6500 Series Switch Supported Power Supply Configurations (continued) Platform Supported Power Supplies Chassis/Power Supply Restrictions Catalyst 6509-NEB-A 2500 W AC-input and DC-input The 6000 W AC-input, 6000 W 3000 W AC-input DC-input, and the 8700 W AC-input power supplies are limited to 4000 W AC-input and DC-input 4500 W maximum output when they 6000 W AC-input and DC-input are installed in the Catalyst 6509-NEB-A switch 8700 W AC-input chassis. Catalyst 6509-V-E 2500 W AC-input and DC-input No restrictions W AC-input 4000 W AC-input and DC-input 6000 W AC-input and DC-input 8700 W AC-input Catalyst W AC-input and DC-input 3000 W AC-input 4000 W AC-input and DC-input 6000 W AC-input and DC-input 8700 W AC-input Catalyst 6513-E 2500 W DC-input 3000 W AC-input 4000 W AC-input and DC-input 6000 W AC-input and DC-input 8700 W AC-input The 8700 W AC-input power supply is limited to 6000 W maximum output when it is installed in the Catalyst 6513 switch chassis. No restrictions. A-4
5 950 W AC-Input and DC-Input Power Supplies 950 W AC-Input and DC-Input Power Supplies The 950 W AC-input (PWR-950-AC) and DC-input (PWR-950-DC) power supplies can be installed in the Catalyst 6503 and Catalyst 6503-E switch chassis only. Due to form factor differences, the 950 W AC-input and DC-input power supplies cannot be installed in any other Catalyst 6500 series switch chassis. The 950 W power supplies (see Figure A-1) do not connect directly to source AC or source DC but use Power Entry Modules (PEMs), located on the front of the Catalyst 6503 and Catalyst 6503-E switch chassis, to connect the site power source to the power supply located in the back of the chassis. The form factor is the same for the AC-input and DC-input power supplies. The AC-input PEM (shown in Figure A-2) and DC-input PEM (shown in Figure A-3) provide an input power connection on the front of the switch chassis to connect the site power source to the power supply. You can connect the DC-input power supply to the power source with heavy gauge wiring connected to a terminal block. The actual wire gauge size is determined by local electrical codes and restrictions. Note The system (NEBS) ground serves as the primary safety ground for Catalyst 6503 and Catalyst 6503-E chassis that are equipped with 950 W DC-input power supplies and DC-input PEMs. The DC-input power supplies for these chassis do not have a separate ground. The PEMs have an illuminated power switch (AC-input model only), current protection, surge and EMI suppression, and filtering functions. Figure A W AC- and DC-Input Power Supplies Status LEDs INPUT FAN OUTPUT OK OK FAIL Captive installation screws Figure A W AC-Input PEM (PEM-15A-AC) IEC C15 connector AC power switch Captive installation screws A-5
6 950 W AC-Input and DC-Input Power Supplies Figure A-3 DC Power Entry Module (PEM) Catalyst 6503 DC PEM Captive installation screws W Table A-3 lists the specifications for the 950 W AC-input power supply. Table A W AC-Input Specification Description AC-input type Autoranging input with power factor correction (PFC) Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal) 90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal) 170 VAC (min) to 264 VAC (max) AC-input current VAC 230VAC AC-input frequency 50/60 Hz (nominal) A-6
7 950 W AC-Input and DC-Input Power Supplies Table A W AC-Input (continued) Specification Branch circuit requirement Description Each chassis power supply should have its own dedicated, fused-branch circuit: For North America 15 A For International Circuits sized to local and national codes All Catalyst 6500 series AC-input power supplies require single-phase source AC. All AC power supply inputs are fully isolated. Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B. Power supply output 950 W maximum ( VAC) capacity Power supply output VDC VDC VDC Output holdup time 20 ms minimum kva rating kva Heat dissipation 4441 BTU/hour (approx.) Weight 8.2 lb (3.7 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. A-7
8 950 W AC-Input and DC-Input Power Supplies Table A-4 lists the specifications for the 950 W DC-input power supply. Table A W DC-Input Specification Description DC-input voltage 48 VDC to 60 VDC continuous DC-input current VDC VDC Power supply output 950 W capacity Power supply output VDC VDC VDC Output holdup time 8 ms Heat dissipation 4632 BTU/hour (approx.) Weight 8.4 lb (3.8 kg) Table A-5 lists the power supply LEDs and their meanings. Table A-5 LED INPUT OK FAN OK OUTPUT FAIL 950 W AC-Input and DC-Input Power Supply LEDs Meaning AC-input power supplies: Green Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off Source AC voltage falls below 70 VAC, is not present, or the PEM is turned off. DC-input power supplies: Green Source DC voltage is OK. ( 40.5 VDC or greater.) Off Source DC voltage falls below 33 VDC or is not present at the PEM. Green Power supply fan is operating properly. Off Power supply fan failure is detected. Red Problem with one or more of the DC-output voltages of the power supply is detected. Off DC-output voltages within acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. A-8
9 950 W AC-Input and DC-Input Power Supplies 950 W Power Supply AC Power Cords Table A-6 lists the 950 W AC-input power supply AC power cords specifications. These power cords plug into the 950 W PEM(PEM-15A-AC), not directly into the power supply. The table includes references to power cord illustrations. Note All 950 W power supply power cords are 8 feet 2 inches (2.5 meters) in length. Note All 950 W power supply power cords have an IEC60320/C15 appliance connector at one end. The appliance connector has a 90 left bend. Table A W AC-Input Power Supply Power Cords Locale Power Cord Part Number AC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7KACR= IRAM A, 250 VAC Figure A-25 Australia, New Zealand CAB-AC10A-90L-AU= SAA AS A, 250 VAC Figure A-20 Continental Europe CAB-AC10A-90L-EU= CEE 7/7 10 A, 250 VAC Figure A-21 Italy CAB-AC10A-90L-IT= CEI 23-16/7 10 A, 250 VAC Figure A-22 Japan, North America CAB-AC15A-90L-US= NEMA A, 125 VAC Figure A-23 United Kingdom CAB-AC10A-90L-UK= BS A, 250 VAC Figure A Plug contains a 13 A fuse. A-9
10 1000 W AC-Input Power Supply 1000 W AC-Input Power Supply The 1000 W AC-input power supply (WS-CAC-1000W) is supported in the following Catalyst 6500 series switches: Catalyst 6506 Catalyst 6509 Catalyst 6509-NEB The 1000 W power supply (shown in Figure A-4) shares the same form factor as the 1300 W, 2500 W, 3000 W, 4000 W, and 6000 W AC-input power supplies. Figure A W AC-Input Power Supply AC power connection Cable retention device I Power switch 0 INPUT OK FAN OK OUTPUT FAIL Status LEDs Captive installation screw A-10
11 1000 W AC-Input Power Supply 1000 W Table A-7 lists the specifications for the 1000 W AC-input power supply. Table A W Specification Description AC-input type Autoranging input with power factor correction (PFC) Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal) 90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal) 170 VAC (min) to 264 VAC (max) AC-input current VAC VAC AC-input frequency 50/60 Hz (nominal) Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch circuit: For North America 15 A or 20 A For International Circuits sized to local and national codes All Catalyst 6500 series AC-input power supplies require single-phase source AC. All AC power supply inputs are fully isolated. Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B. A-11
12 1000 W AC-Input Power Supply Table A W (continued) Specification Description Power supply output 1000 W capacity Power supply output VDC +5VDC +12VDC +42VDC Output holdup time 20 ms minimum kva rating kva Heat dissipation 4213 BTU/hour (approx.) Weight 14.8 lb (6.7 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-8 list the power supply LEDs and their meanings. Table A W Power Supply LEDs LED Meaning INPUT OK Green Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. FAN OK Green Power supply fan is operating properly. Off Power supply fan failure is detected. OUTPUT FAIL Red Problem with one or more of the DC-output voltages of the power supply is detected. Off DC-output voltage with acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. A-12
13 1300 W AC-Input and DC-Input Power Supplies 1000 W Power Supply AC Power Cords Table A-9 lists the specifications for the AC power cords that are available for the 1000 W AC-input power supply. The table includes references to power cord illustrations. Note All 1000 W power supply power cords are 8 feet 2 inches (2.5 meters) in length. Note All 1000 W power supply power cords have an IEC60320/C15 appliance plug at one end. Table A W AC-Input Power Supply Power Cords Locale Power Cord Part Number AC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7KACR= IRAM A, 250 VAC Figure A-25 Australia, New Zealand CAB-7KACA= SAA AS A, 250 VAC Figure A-26 Continental Europe CAB-7KACE= CEE 7/7 16 A, 250 VAC Figure A-27 Italy CAB-7KACI= CEI 23-16/7 10 A, 250 VAC Figure A-28 Japan, North America CAB-7KAC-15= NEMA A, 125 VAC Figure A-29 United Kingdom CAB-7KACU= BS A, 250 VAC Figure A Plug contains a 13 A fuse W AC-Input and DC-Input Power Supplies The 1300 W AC-input power supply (WS-CAC-1300W) and 1300 W DC-input power supply (WS-CDC-1300W) are supported in the following Catalyst 6500 series switches: Catalyst 6506 Catalyst 6509 Catalyst 6509-NEB The 1300 W power supply (see Figure A-5 for the 1300 W AC-input power supply and Figure A-6 for the 1300 W DC-input power supply) shares the same form factor as the 1000 W, 2500 W, 3000 W, 4000 W, and 6000 W AC-input power supplies. A-13
14 1300 W AC-Input and DC-Input Power Supplies Figure A W AC-input Power Supply AC power connection Cable retention device I Power switch 0 INPUT OK FAN OK OUTPUT FAIL Status LEDs Captive installation screw Figure A W DC-Input Power Supply Terminal block cover o INPUT OK FAN OK OUTPUT FAIL Captive installation screw A-14
15 1300 W AC-Input and DC-Input Power Supplies 1300 W Table A-11 lists the specifications for the 1300 W AC-input power supply. Table A W AC-Input Specification Description AC-input type Autoranging input with power factor correction (PFC). Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal) 90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal) 170 VAC (min) to 264 VAC (max) AC-input current VAC VAC AC-input frequency 50/60 Hz (nominal) (±3 Hz for full range) Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch circuit: Power supply output capacity For North America 15 A or 20 A For International Circuits sized to local and national codes All Catalyst 6500 series AC-input power supplies require single-phase source AC. All AC power supply inputs are fully isolated. Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B W maximum (AC-input) 1360 W maximum (DC-input) Power supply output VDC +5VDC +12VDC VDC Output holdup time 20 ms minimum A-15
16 1300 W AC-Input and DC-Input Power Supplies Table A W AC-Input (continued) Specification kva rating 1 Heat dissipation Weight Description kva 5478 BTU/hour (approx.) 18.4 lb (8.3 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-11 lists the specifications for the 1300 W DC-input power supply. Table A W DC-Input Specification Description DC-input voltage 48 VDC to 60 VDC continuous DC-input current VDC VDC Power supply output 1360 W maximum (DC-input) capacity Power supply output VDC +5VDC +12VDC +42VDC DC input terminal block Accepts 3 AWG to 10 AWG copper conductors. Actual size of the wire needed is determined by the installer or local electrician. Terminal block material is rated at 120 C. Output holdup time 8 ms Heat dissipation 6447 BTU/hour (approx.) Weight 21.0 lb (9.5 kg) Table A-12 lists the 1300 W power supply LEDS and their meanings. A-16
17 1300 W AC-Input and DC-Input Power Supplies Table A W AC-Input and DC-Input Power Supply LEDs LED INPUT OK Meaning AC-input power supplies: Green Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off Source AC voltage falls below 70 VAC, is not present, or the power supply turned off. DC-input power supplies: Green Source DC voltage is OK. (Input voltage is 40.5 VDC or greater.) Off Source DC voltage falls below 33 VDC, is not present, or the power supply is turned off. FAN OK Green Power supply fan is operating properly. Off Power supply fan failure is detected. OUTPUT FAIL Red Problem with one or more of the DC-output voltages of the power supply is detected. Off DC-output voltages within acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal W Power Supply AC Power Cords Table A-13 lists the specifications for the AC power cords that are available for the 1300 W AC-input power supply. The table includes references to power cord illustrations. Note All 1300 W power supply power cords are 14 feet (4.3 meters) in length. Note All 1300 W power supply power cords have an IEC60320/C19 appliance connector at one end. A-17
18 1400 W AC-Input Power Supply TableA W Power Supply AC Power Cords Locale Power Cord Part Number AC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7513ACR= IRAM A, 250 VAC Figure A-31 Australia, New Zealand CAB-7513ACA= SAA AS A, 250 VAC Figure A-32 Continental Europe CAB-7513ACE= CEE 7/7 16 A, 250 VAC Figure A-33 Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VAC Figure A-34 Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VAC Figure A-35 Japan, North America CAB-7513AC= NEMA A, 125 VAC Figure A-36 People s Republic of CAB-AC16A-CH= GB16C 16 A, 250 VAC Figure A-37 China South Africa CAB-7513ACSA= IEC A, 250 VAC Figure A-38 Switzerland CAB-ACS-10= SEV A, 250 VAC Figure A-39 United Kingdom CAB-7513ACU= BS A, 250 VAC Figure A-40 Power Distribution Unit (PDU) 3 CAB-C19-CBN= IEC C19 IEC C20 16 A, 250 VAC Figure A For Japan, ask your local electrical contractor to prepare the NEMA 5-20 power plug. 2. Plug contains a 13 A fuse. 3. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector W AC-Input Power Supply The 1400 W AC-input power supply (PWR-1400-AC) can be installed in the Catalyst 6503 switch and Catalyst 6503-E switch chassis only. Due to form factor differences, the 1400 W AC-input power supply cannot be installed in any other Catalyst 6500 series switch chassis. The 1400 W power supplies (see Figure A-7) do not connect directly to source AC but use power entry modules (PEMs), located on the front of the Catalyst 6503 and Catalyst 6503-E switch chassis, to connect the site power source to the power supply located in the back of the chassis. The AC-input PEM (PEM-20A-AC+) (shown in Figure A-8) provides an input power connection on the front of the router chassis to connect the site power source to the power supply. The PEMs have an illuminated power switch, current protection, surge and EMI suppression, and filtering functions. A-18
19 1400 W AC-Input Power Supply Figure A W AC-Input Power Supply (PWR-1400-AC) Status LEDs INPUT FAN OUTPUT OK OK FAIL Captive installation screws Figure A W AC-Input PEM (PEM-20A-AC+) IEC C19 connector V 15A Hz PEM-20A-AC+ AC power switch Captive installation screws W Table A-14 lists the specifications for the 1400 W AC-input power supply. Table A W AC-Input Specification Description AC-input type Autoranging input with power factor correction (PFC). Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal) 90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal) 170 VAC (min) to 264 VAC (max) AC-input current VAC VAC AC-input frequency 50/60 Hz (nominal) (±3 Hz for full range) A-19
20 1400 W AC-Input Power Supply Table A W AC-Input (continued) Specification Description Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch circuit: For North America 20 A For International Circuits sized to local and national codes All AC power supply inputs are fully isolated. Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B. Power supply output 1400 W capacity Power supply output V V +50V Output holdup time 20 ms minimum kva rating kva Heat dissipation 5976 BTU/hour (approx.) Weight 7.8 lb (3.5 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-15 lists the 1400 W AC-input power supply LEDs and their meanings. A-20
21 1400 W AC-Input Power Supply Table A W AC-Input Power Supply LEDs LED Meaning INPUT OK Green Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. FAN OK Green Power supply fan is operating properly. Off Power supply fan failure is detected. OUTPUT FAIL Red Problem with one or more of the DC-output voltages of the power supply is detected. DC-output voltages within acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal W Power Supply AC Power Cords Table A-16 lists the specifications for the AC power cords that are available for the 1400 W AC-input power supply. These power cords plug into the 1400 W PEM (PEM-20A-AC+); not directly into the power supply. The table includes references to power cord illustrations. Note All 1400 W power supply power cords are 14 feet (4.3 meters) in length. Note All 1400 W power supply power cords have an IEC60320/C19 appliance plug at one end. A-21
22 1400 W AC-Input Power Supply TableA W Power Supply AC Power Cords Locale Argentina Power Cord Part Number CAB-7513ACR= CAB-IR2073-C19-AR= AC Source Plug Type Cordset Rating Power Cord Reference Illustration IRAM A, 250 VAC Figure A-31 Australia, New Zealand CAB-7513ACA= SAA AS A, 250 VAC Figure A-32 People s Republic of CAB-AC16A-CH= GB16C 16 A, 250 VAC Figure A-37 China Continental Europe CAB-7513ACE= CAB-AC-2500W-EU= CEE 7/7 CEE 7/7 16 A, 250 VAC 16 A, 250 VAC Figure A-33 Figure A-41 International CAB-AC-2500W-INT= IEC A, 250 VAC Figure A-42 Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VAC Figure A-34 Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VAC Figure A-35 Japan, North America CAB-7513AC= CAB-AC-2500W-US1= CAB-AC-C6K-TWLK= NEMA NEMA NEMA L A, 125 VAC 16 A, 250 VAC 16 A, 250 VAC Figure A-36 Figure A-43 Figure A-44 South Africa CAB-7513ACSA= IEC A, 250 VAC Figure A-38 Switzerland CAB-ACS-10= SEV A, 250 VAC Figure A-39 Switzerland CAB-ACS-16= SEV Type A, 250 VAC Figure A-45 United Kingdom CAB-7513ACU= BS A, 250 VAC 4 Figure A-40 Power Distribution Unit (PDU) 5 CAB-C19-CBN= IEC C19 IEC C20 1. For operation in Japan, ask your local electrical contractor to prepare the NEMA 5-20 power plug. 2. For operation in Japan, ask your local electrical contractor to prepare the NEMA 6-20 power plug. 16 A, 250 VAC Figure A For operation in Japan, ask your local electrical contractor to prepare the NEMA L6-20 power plug. 4. Plug contains a 13 A fuse. 5. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. A-22
23 2500 W AC-Input and DC-Input Power Supplies 2500 W AC-Input and DC-Input Power Supplies The 2500 W AC-input power supply (WS-CAC-2500W) and 2500 W DC-input power supply (WS-CDC-2500W) are supported in the following Catalyst 6500 series switches: Catalyst 6506 Catalyst 6506-E Catalyst 6509 Catalyst 6509-E Catalyst 6509-NEB Catalyst 6509-NEB-A Catalyst 6509-V-E Catalyst 6513 Catalyst 6513-E (DC-input power supply only) The 2500 W power supplies, shown in Figure A-9 and Figure A-10, share the same form factor as the 1000 W, 1300 W, 3000 W, 4000 W, and 6000 W AC-input power supplies. Note With a fully populated Catalyst 6513 switch, two 2500 W power supplies are not fully redundant. If you operate the 2500 W power supply at the low range input (100 to 120 VAC), it is not redundant in a fully populated Catalyst 6509, Catalyst 6509-E, Catalyst 6509-NEB, Catalyst 6509-NEB-A, or Catalyst 6509-V-E switch. Note The 2500 W AC-input power supply needs 220 VAC to deliver 2500 W of power. When powered with 110 VAC, it delivers only 1300 W. In addition, the power supply needs 16 A, regardless of whether it is plugged into 110 VAC or 220 VAC. Figure A W AC-Input Power Supply AC power connection Cable retention device I Power switch 0 INPUT OK FAN OK OUTPUT FAIL Status LEDs Captive installation screw A-23
24 2500 W AC-Input and DC-Input Power Supplies Figure A W DC-input Power Supply Terminal block cover o INPUT OK FAN OK OUTPUT FAIL Captive installation screw 2500 W Table A-17 lists the specifications for the 2500 W AC-input and DC-input power supplies. Table A W AC-Input Specification Description AC-input type Autoranging input with power factor correction (PFC). Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal) 90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal) 170 VAC (min) to 264 VAC (max) AC-input current 16 A maximum at 230 VAC at 2500 W output 16 A maximum at 120 VAC at 1300 W output AC-input frequency 50/60 Hz (nominal) (±3% for full range) A-24
25 2500 W AC-Input and DC-Input Power Supplies Table A W AC-Input (continued) Specification Branch circuit requirement Power supply output capacity Description Each chassis power supply should have its own dedicated, fused-branch circuit: For North America 20 A For International Circuits sized to local and national codes All AC power supply inputs are fully isolated. Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B W maximum ( VAC) 2500 W maximum ( VAC) Power supply output 100/120 VAC operation VDC +5VDC VDC VDC 200/240 VAC operation VDC +5VDC VDC VDC Output holdup time 20 ms minimum kva rating W (total input power) or 3.6 KVA (high-line operation) Heat dissipation 10,939 BTU/hour (approx.) Weight 17.0 lb (7.7 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-18 lists the specifications for the 2500 W DC-input power supply. A-25
26 2500 W AC-Input and DC-Input Power Supplies Table A W DC-Input Specification Description DC-input voltage 48 VDC to 60 VDC continuous DC-input current VDC VDC VDC Power supply output 2500 W maximum ( 48 to 60 VDC) capacity Power supply output VDC +5VDC VDC +42VDC DC input terminal block Accepts 2 14 AWG copper conductors. Actual size of the wire needed is determined by the installer or local electrician. Terminal block material rated at 150 C. Output holdup time 20 ms minimum (AC-input power supply) 4 ms (DC-input power supply) Heat dissipation 10,939 BTU/hour (approx.) AC-input power supply 11,377 BTU/hour (approx.) DC-input power supply Weight 20.2 lb (9.2 kg) Table A-19 lists the power supply LEDs and their meanings. A-26
27 2500 W AC-Input and DC-Input Power Supplies Table A W AC-Input and DC-Input Power Supply LEDs LED INPUT OK Meaning AC-input power supplies: Green Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. DC-input power supplies: Green Source DC voltage is OK. (Input voltage is 40.5 VDC or greater.) Off Source DC voltage falls below 33 VDC, is not present, or the power supply is turned off. FAN OK Green Power supply fan is operating properly. Off Power supply fan failure is detected. OUTPUT FAIL Red Problem with one or more of the DC-output voltages of the power supply. Off DC-output voltages within acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. A-27
28 2500 W AC-Input and DC-Input Power Supplies 2500 W Power Supply AC Power Cords Table A-20 lists the specifications for the AC power cords that are available for the 2500 W AC-input power supply. The table includes references to power cord illustrations. Note All 2500 W power supply power cords are 14 feet (4.3 meters) in length. Note All 2500 W power supply power cords have an IEC60320/C19 appliance connector at one end. TableA W Power Supply AC Power Cords Locale Power Cord Part Number AC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7513ACR= or IRAM A, 250 VAC Figure A-31 CAB-IR2073-C19-AR= Australia, New Zealand CAB-AC-16A-AUS= AU20S3 16 A, 250 VAC Figure A-46 People s Republic of China CAB-AC16A-CH= GB16C 16 A, 250 VAC Figure A-37 Continental Europe CAB-AC-2500W-EU= CEE 7/7 16 A, 250 VAC Figure A-41 International CAB-AC-2500W-INT= IEC A, 250 VAC Figure A-42 Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VAC Figure A-34 Japan, North America VAC operation CAB-AC-2500W-US1= NEMA 6-20 (nonlocking plug) 16 A, 250 VAC Figure A-43 Japan, North America VAC operation Japan, North America VAC operation 1 Power Distribution Unit (PDU) 2 CAB-AC-C6K-TWLK= NEMA L A, 250 VAC Figure A-44 (locking plug) CAB-7513AC= NEMA A, 125 VAC Figure A-36 CAB-C19-CBN IEC C19 IEC C20 16 A, 250 VAC Figure A-47 Switzerland CAB-ACS-16= SEV Type A, 250 VAC Figure A The 2500 W power supply operating on 110 VAC delivers 1300 W. 2. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. A-28
29 2700 W AC-Input and DC-Input Power Supplies 2700 W AC-Input and DC-Input Power Supplies The 2700 W AC-input power supply (PWR-2700-AC/4) and 2700 W DC-input power supply (PWR-2700-DC/4) are supported only in the Catalyst 6504-E switch. See Figure A-11 for the 2700 W AC-input power supply and Figure A-12 for the 2700 W DC-input power supply. Note The 2700 W AC-input power supply needs 220 VAC to deliver 2700 W of power. When powered with 110 VAC, it delivers only 1350 W. In addition, the power supply needs 16 A, regardless of whether it is plugged into 110 VAC or 220 VAC. Figure A W AC-Input Power Supply 1 2 PWR-2700-AC/4 3 5 ALL FASTENERS MUST BE FULLY ENGAGED PRIOR TO OPERATING THE POWER SUPPLY Power on/off switch ( /O) 4 Status LEDs 2 Power supply fan 5 AC In receptacle 3 Captive installation screw (4x) A-29
30 2700 W AC-Input and DC-Input Power Supplies Figure A W DC-Input Power Supply 2 3 PWR-2700-DC/4 -VE-1 -VE-1 INPUT1 INPUT2 FAN OUTPUT OK OK OK FAIL 48V-60V 48V-60V =40A =40A -VE-2 -VE-2 4 ALL FASTENERS MUST BE FULLY ENGAGED PRIOR TO OPERATING THE POWER SUPPLY Captive installation screw (4x) 7 Fixed cable guide, top half 2 Source DC terminal block 8 Detached cable guide, bottom half 3 Status LEDs 9 Tie-wrap (for source DC cables) 4 Terminal block cover 10 Fixed cable guide, bottom half 5 Detached cable guide, top half 11 Tie-wrap (for ground cable) 6 Ground terminal block A-30
31 2700 W AC-Input and DC-Input Power Supplies 2700 W Table A-22 lists the specifications for the 2700 W AC-input power supply. Table A W AC-Input Specification Description AC-input type Autoranging input with power factor correction (PFC). Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal) 90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal) 170 VAC (min) to 264 VAC (max) AC-input current 16 A maximum at 230 VAC at 2700 W output 16 A maximum at 120 VAC at 1350 W output AC-input frequency 50/60 Hz (nominal) (±3% for full range) Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch circuit: Power supply output capacity For North America 20 A For International Circuits sized to local and national codes All AC power supply inputs are fully isolated. Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B W maximum ( VAC) 2700 W maximum ( VAC) A-31
32 2700 W AC-Input and DC-Input Power Supplies Table A W AC-Input (continued) Specification Power supply output 100/120 VAC operation Output holdup time kva rating 1 Heat dissipation Weight Description VDC VDC VDC 200/240 VAC operation VDC VDC VDC 20 ms minimum 3.4 KVA (high-line operation) 11,238 BTU/hour (approx.) 18.5 lb (8.4 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-22 lists the 2700 W DC-input power supply specifications. Table A W DC-Input Specification Description DC-input voltage A for nominal 48 V battery backup system (operating range: 40.5 VDC to 56 VDC) DC-input current (per DC input) Power supply output capacity A for nominal 60 V battery backup system (operating range: 55 VDC to 72 VDC) VDC VDC VDC Note For multiple DC input power supplies, each DC input must be protected by a dedicated circuit breaker or a fuse. The circuit breaker or the fuse must be sized according to the power supply input power rating and any local or national electrical code requirements W maximum ( 48 to 60 VDC, with one DC input) 2700 W maximum ( 48 to 60 VDC, with two DC inputs) A-32
33 2700 W AC-Input and DC-Input Power Supplies Table A W DC-Input (continued) Specification Power supply output One DC input operation (1350 W operation) DC input terminal block Output holdup time kva rating 1 Heat dissipation Weight Description VDC VDC VDC Two DC inputs operation (2700 W operation VDC VDC VDC Accepts 2 14 AWG copper conductors. Actual size of the wire needed is determined by the installer or local electrician. Terminal block material rated at 150 C. 4 ms 3.5 KW 11,968 BTU/hour (approx.) 21.0 lb (9.5 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-23 lists the power supply LEDs and their meanings. A-33
34 2700 W AC-Input and DC-Input Power Supplies Table A W AC-Input and DC-Input Power Supply LEDs LED INPUT 1 OK INPUT 2 OK (DC-input power supply only) Meaning AC-input power supplies: Green Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. DC-input power supplies: Green Source DC is OK. (Input voltage is 40.5 VDC or greater.) Off Source DC voltage falls below 33 VDC, is not present, or the power supply is turned off. FAN OK Green Power supply fan is operating properly. Off Power supply fan failure is detected. OUTPUT FAIL Red Problem with one or more of the DC-output voltages of the power supply. Off DC-output voltages within acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. A-34
35 2700 W AC-Input and DC-Input Power Supplies 2700 W Power Supply AC Power Cords Table A-24 lists the specifications for the AC power cords that are available for the 2700 W AC-input power supply. The table includes references to power cord illustrations. Note All 2700 W power supply power cords are 14 feet (4.3 meters) in length. Note All 2700 W power supply power cords have an IEC60320/C19 appliance connector at one end. TableA W Power Supply AC Power Cords Locale Power Cord Part Number AC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7513ACR= or IRAM A, 250 VAC Figure A-31 CAB-IR2073-C19-AR= Australia, New Zealand CAB-AC-16A-AUS= AU20S3 16 A, 250 VAC Figure A-45 People s Republic of China CAB-AC16A-CH= GB16C 16 A, 250 VAC Figure A-37 Continental Europe CAB-AC-2500W-EU= CEE 7/7 16 A, 250 VAC Figure A-41 International CAB-AC-2500W-INT= IEC A, 250 VAC Figure A-42 Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VAC Figure A-34 Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VAC Figure A-35 Japan, North America VAC operation CAB-AC-2500W-US1= NEMA 6-20 (nonlocking plug) 16 A, 250 VAC Figure A-43 Japan, North America VAC operation Japan, North America VAC operation Power Distribution Unit (PDU) 1 CAB-AC-C6K-TWLK= NEMA L6-20 (locking plug) 16 A, 250 VAC Figure A-44 CAB-7513AC= NEMA A, 125 VAC Figure A-36 CAB-C19-CBN= IEC C19 IEC C20 16 A, 250 VAC Figure A-47 South Africa CAB-7513ACSA= IEC A, 250 VAC Figure A-38 Switzerland CAB-ACS-16= SEV Type A, 250 VAC Figure A The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. A-35
36 3000 W AC-Input Power Supply 3000 W AC-Input Power Supply The 3000 W AC-input power supply (WS-CAC-3000W) is supported in the following Catalyst 6500 series switches: Catalyst 6506 Catalyst 6506-E Catalyst 6509 Catalyst 6509-E Catalyst 6509-NEB Catalyst 6509-NEB-A Catalyst 6509-V-E Catalyst 6513 Catalyst 6513-E The 3000 W power supply (see Figure A-13) shares the same form factor as the 1000 W, 1300 W, 2500 W, 4000 W, and 6000 W AC-input power supplies. Note The 3000 W AC-input power supply needs 220 VAC to deliver 3000 W of power. When operating with 110 VAC, it delivers only 1400 W. In addition, the power supply needs 16 A, regardless of whether it is plugged into 110 VAC or 220 VAC. Figure A W AC-Input Power Supply AC power connection Cable retention device V - 15A V - 15A 60/50HZ Power switch O INSTALL RUN I INPUT FAN OUTPUT OK OK FAIL OUTPUT 42V /17A 42V /17A OK + Captive installation screw Status LEDs (3) External power connector cover A-36
37 3000 W AC-Input Power Supply 3000 W Table A-25 lists the specifications for the 3000 W AC-input power supply. Table A W Specification Description AC-input type Autoranging input with power factor correction (PFC). Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal) 90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal) 170 VAC (min) to 264 VAC (max) AC-input current VAC (3000 W output) VAC (1400 W output) AC-input frequency 50/60 Hz (nominal) (±3% for full range) Branch circuit requirement Each chassis power supply should have its own dedicated, fused-branch circuit: Power supply output capacity For North America 20 A For International Circuits sized to local and national codes All AC power supply inputs are fully isolated. Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B W maximum ( VAC) 3000 W maximum ( VAC) A-37
38 3000 W AC-Input Power Supply Table A W (continued) Specification Power supply output 100/120 VAC operation Front panel power connector Output holdup time kva rating 1 Heat dissipation Weight Description V +5V V V 200/240 VAC operation V +5V V V A two-pin male Molex connector is located in the lower right corner of the power supply front panel. The connector provides 42 VDC at a maximum of 17 A. This connector provides power to the WS-6509-NEB-UPGRD kit fan assembly through a power harness also provided in the kit. A hinged protective flap secured by a captive screw covers the connector when it is not in use. 20 ms minimum 3520 W (total input power) or 3.6 KVA (high-line operation) 12,046 BTU/hour (approx.) 15.8 lb (7.2 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-26 lists the power supply LEDs and their meanings. A-38
39 3000 W AC-Input Power Supply TableA W AC-Input Power Supply LEDs LED Meaning INPUT OK Green Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. FAN OK Green Power supply fan is operating properly. Off Power supply fan failure is detected. OUTPUT FAIL Red Problem with one or more of the DC-output voltages of the power supply. Off DC-output voltages within acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. 42V OK Green 42 VDC is present at the fan power connector. Off 42 VDC is not present at the fan power connector. A-39
40 3000 W AC-Input Power Supply 3000 W Power Supply AC Power Cords Table A-27 lists the specifications for the AC power cords that are available for the 3000 W AC-input power supply. The table includes references to power cord illustrations. Note All 3000 W power supply power cords are 14 feet (4.3 meters) in length. Note All 3000 W power supply power cords have an IEC60320/C19 appliance connector at one end. TableA W Power Supply AC Power Cords Locale Power Cord Part Number AC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7513ACR= or IRAM A, 250 VAC Figure A-31 CAB-IR2073-C19-AR= Australia, New Zealand CAB-AC-16A-AUS= AU20S3 16 A, 250 VAC Figure A-46 People s Republic of China CAB-AC16A-CH= GB16C 16 A, 250 VAC Figure A-37 Continental Europe CAB-AC-2500W-EU= CEE 7/7 16 A, 250 VAC Figure A-41 International CAB-AC-2500W-INT= IEC A, 250 VAC Figure A-42 Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VAC Figure A-34 Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VAC Figure A-35 Japan, North America (nonlocking plug) VAC operation CAB-AC-2500W-US1= NEMA A, 250 VAC Figure A-43 Japan, North America (locking plug) VAC operation Japan, North America VAC operation 1 Power Distribution Unit (PDU) 2 CAB-AC-C6K-TWLK= NEMAL A, 250VAC Figure A-44 CAB-7513AC= NEMA A, 125 VAC Figure A-36 CAB-C19-CBN= IEC C19 IEC C20 16 A, 250 VAC Figure A-47 Switzerland CAB-ACS-16= SEV Type A, 250 VAC Figure A The 3000 W power supply operating on 110 VAC delivers 1400 W. 2. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. A-40
41 4000 W AC-Input and DC-Input Power Supplies 4000 W AC-Input and DC-Input Power Supplies The 4000 W AC-input and DC-input power supplies, (WS-CAC-4000W-US, WS-CAC-4000W-INT, and PWR-4000-DC) are supported in the following Catalyst 6500 series switches: Catalyst 6506 Catalyst 6506-E Catalyst 6509 Catalyst 6509-E Catalyst 6509-NEB Catalyst 6509-NEB-A Catalyst 6509-V-E Catalyst 6513 Catalyst 6513-E The 4000 W AC-input and DC-input power supplies, shown in Figure A-14 and Figure A-15, share the same form factor as the 1000 W, 1300 W, 2500 W, and 3000 W power supplies. Figure A W AC-Input Power Supply I Power switch 0 INPUT OK FAN OK OUTPUT FAIL Captive installation screw Status LEDs A-41
42 4000 W AC-Input and DC-Input Power Supplies Figure A W DC-Input Power Supply +VE-1 +VE-3 -VE-1 -VE-3 +VE-2 -VE-2 I INPUT OK FAN OUTPUT OK FAIL 4000 W Table A-29 lists the specifications for the 4000 W AC-input power supply. Table A W AC-Input Specification AC-input type AC-input voltage AC-input current AC-input frequency Description High-line input with power factor correction (PFC). Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. High-line (230 VAC nominal) 170 VAC (min) to 264 VAC (max) 23 A 50/60 Hz (nominal) (±3% for full range) A-42
43 4000 W AC-Input and DC-Input Power Supplies Table A W AC-Input (continued) Specification Branch circuit requirement Description Each chassis power supply should have its own dedicated, fused-branch circuit: For North America 30 A For International Circuits should be sized according to local and national codes All AC power supply inputs are fully isolated. Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B. Output capacity 4000 W maximum Power supply output VDC +5VDC VDC VDC Output holdup time 20 ms minimum kva rating kva maximum Heat dissipation 17,065 BTU/hour (approx.) Weight 22.2 lb (10.1 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-29 list the specification for the 4000 W DC-input power supply. A-43
44 4000 W AC-Input and DC-Input Power Supplies Table A W DC-Input Specification Description DC-input voltage A for nominal 48 V battery backup system (operating range: 40.5 VDC to 56 VDC) DC-input current Power supply output capacity A for nominal 60 V battery backup system (operating range: 55 VDC to 72 VDC) Note The 4000 W DC-input power supply requires two source DC-inputs to be connected; it cannot operate with only one positive (+)/negative (-) source DC terminal pair installed. 40 A per each DC input (three inputs) Note For multiple DC input power supplies, each DC input must be protected by a dedicated circuit breaker or a fuse. The circuit breaker or the fuse must be sized according to the power supply input power rating and any local or national electrical code requirements W with three inputs active 2700 W with two inputs active Note The 4000 W power supply cannot operate with only one source DC-input connected. Power supply output VDC + 5 VDC VDC A (three inputs) or A (two +42 VDC DC input terminal block Output holdup time kva rating 1 Heat dissipation Weight Note The 4000 W power supply cannot operate with only one source DC-input connected. Accepts 4 AWG copper conductors. Actual size of the wire needed is determined by the installer or local electrician. 8 ms 5.4 kva maximum 17,730 BTU/hour (approx.) 30.8 lb (14.0 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-30 lists the power supply LEDs and their meanings. A-44
45 4000 W AC-Input and DC-Input Power Supplies Table A W AC-Input and DC-Input Power Supplies LEDs LED INPUT OK Meaning AC-input power supplies: Green Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. DC-input power supplies: Green Source DC voltage is OK. (Input voltage is 40.5 VDC or greater.) Off Source DC voltage falls below 33 VDC, is not present, or the power supply is turned off. FAN OK Green Power supply fan is operating properly. Off Power supply fan failure is detected. OUTPUT FAIL Red Problem with one or more of the DC-output voltages of the power supply. Off DC-output voltages within acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. A-45
46 6000 W AC-Input and DC-Input Power Supplies 4000 W Power Supply AC Power Cords Table A-31 lists the specifications for the AC power cords that are available for the 4000 W AC-input power supply. Included in the table are references to illustrations of the power cords. Note The AC power cords for the 4000 W AC-input power supply are hardwired directly to the power supply; they do not have an IEC C19 appliance plug and cannot be removed from the power supply. TableA W Power Supply AC Power Cords Locale Power Cord Part Number 1 AC Source Plug Type Cordset Rating Power Cord Reference Illustration International WS-CAC-4000W-INT= IEC A, 250 VAC Figure A-48 North America, Japan WS-CAC-4000W-US= NEMA L A, 250 VAC Figure A This is the part number for the power supply. The AC power cords are hardwired to the 4000 W power supplies. 2. For Japan, ask your local electrical contractor to prepare the NEMA L6-30 power plug W AC-Input and DC-Input Power Supplies Catalyst 6500 series switch support for the 6000 W AC-input (WS-CAC-6000W) and the 6000 W DC-input (PWR-6000-DC) power supplies along with any power supply output restrictions are listed in Table A-32. Table A-32 Chassis Support for the 6000 W AC-Input and DC-Input Power Supplies Catalyst 6500 Series Chassis 6000 W AC-Input Power Supply Restriction 6000 W DC-Input Power Supply Restriction Catalyst 6506 Output limited to 4000 W Output limited to 4000 W Catalyst 6506-E No restrictions No restrictions Catalyst 6509 Output limited to 4000 W Output limited to 4000 W Catalyst 6509-E No restrictions No restrictions Catalyst 6509-NEB Output limited to 4000 W Output limited to 4000 W Catalyst 6509-NEB-A Output limited to 4500 W Output limited to 4500 W Catalyst 6509-V-E No restrictions No restrictions Catalyst 6513 No restrictions No restrictions Catalyst 6513-E No restrictions No restrictions The 6000 W AC-input power supply, shown in Figure A-16, and the 6000 W DC-input power supply, shown in Figure A-17, share the same form factor as the 1000 W, 1300 W, 2500 W, 3000 W, and 4000 W power supplies. A-46
47 CISCO SYSTEMS, INC INPUT OK 6000 W AC-Input and DC-Input Power Supplies Note Because of form-factor differences, the 6000 W AC-input and the 6000 W DC-input power supplies cannot be installed in the Catalyst 6503, Catalyst 6503-E, and Catalyst 6504-E switch chassis. Figure A W AC-Input Power Supply Cable retention device AC power connection 1 INPUT V 15A 50/60 Hz AC power connection 2 Power switch 0 INSTALL RUN I INPUT V 15A 50/60 Hz INPUT OK FAN OK OUTPUT FAIL Status LEDs Captive installation screw Figure A W DC-Input Power Supply RUN INSTALL FAN OK OUTPUT FAIL A-47
48 6000 W AC-Input and DC-Input Power Supplies 6000 W Table A-34 lists the specifications for the 6000 W AC-input power supply. Table A W AC-Input Specification AC-input type Description 2 AC-inputs per power supply. High-line input with power factor correction (PFC) included. Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. AC-input voltage Low-line (120 VAC nominal) 90 VAC (min) to 132 VAC (max) AC-input current AC-input frequency High-line (230 VAC nominal) 170 VAC (min) to 264 VAC (max) 16 A each input 50/60 Hz (nominal) (±3% for full range) A-48
49 6000 W AC-Input and DC-Input Power Supplies Table A W AC-Input (continued) Specification Branch circuit requirement Description Each power supply input should have its own dedicated, fused-branch circuit: For North America 20 A For International Circuits should be sized according to local and national codes All Catalyst 6500 series AC-input power supplies require single-phase source AC. All AC power supply inputs are fully isolated. Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B. A-49
50 6000 W AC-Input and DC-Input Power Supplies Table A W AC-Input (continued) Specification Power supply output capacity Description The 6000 W power supply can operate at either 2900 W or 6000 W depending on the number of AC power cords attached and the source AC voltage. Note The 6000 W AC-input power supply is limited to 4000 W maximum output when it is installed in a Catalyst 6506, Catalyst 6509, or Catalyst 6509-NEB switch chassis. The power supply is limited to 4500 W maximum output when it is installed in the Catalyst 6509-NEB-A switch chassis W maximum with the following source AC arrangements: INPUT 1 and INPUT 2 both connected to low-line (120 VAC nominal) INPUT 1 connected to high-line (230 VAC nominal); INPUT 2 not connected INPUT 1 not connected; INPUT 2 connected to high-line (230 VAC nominal) INPUT 1 connected to high-line (230 VAC nominal); INPUT 2 connected to low-line (120 VAC nominal) INPUT 1 connected to low-line (120 VAC nominal); INPUT 2 connected to high-line (230 VAC nominal) 6000 W maximum with the following source AC arrangements: Note INPUT 1 and INPUT 2 both connected to high-line (230 VAC nominal) The 6000 W power supply will not power up if you have only one power cord plugged into either INPUT 1 or INPUT 2 and source AC is low-line (120 VAC nominal). A-50
51 6000 W AC-Input and DC-Input Power Supplies Table A W AC-Input (continued) Specification Power supply output capacity 2900 W operation (one 220 VAC source or two 110 VAC sources) Output holdup time kva rating 1 Heat dissipation System power dissipation Weight Description VDC VDC VDC 6000 W operation (two 220 VAC sources) VDC VDC VDC 20 ms minimum 7.5 kva 23,812 BTU/hour (approx.) 7034 W 25.4 lb (11.5 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-34 list the specifications for the 6000 W DC-input power supply. Table A W DC-Input Specification Description Input voltage 48 VDC 37 A in North America (operating range: 40.5 VDC to 56 VDC) Input current Power supply output capacity 60 VDC 30 A for international (operating range: 55 VDC to 72 VDC) 40 A per DC 48 VDC input voltage (total of 4 inputs) The 6000 W DC-input power supply can operate at either: 2800 W 2 DC inputs active 4500 W 3 DC inputs active 6000 W 4 DC inputs active A-51
52 6000 W AC-Input and DC-Input Power Supplies Table A W DC-Input (continued) Specification Description Power supply output The 6000 W DC-input power supply can operate at either 2800 W, 4500 W, or 6000 W depending on the number of source DC power cables attached. Note The 6000 W DC-input power supply is limited to 4000 W maximum output when it is installed in a Catalyst 6506, Catalyst 6509, or Catalyst 6509-NEB switch chassis. The power supply is limited to 4500 W maximum output when it is installed in the Catalyst 6509-NEB-A switch chassis W operation (two DC inputs) VDC VDC VDC 4500 W operation (three DC inputs) VDC VDC VDC 6000 W operation (four DC inputs) VDC VDC VDC DC input terminal block Accepts 2-hole copper compression-type lugs. Note The actual size of the wire needed is determined by the power engineer or local electrician in accordance with national or local electrical codes. Output holdup time Weight Terminal posts accept 1/4-inch-20 hex nuts. 20 ms minimum 35 lbs (16 kg) Table A-35 list the 6000 W AC-input and DC-input power supply LEDs and their meanings. A-52
53 6000 W AC-Input and DC-Input Power Supplies Table A W AC-Input and DC-Input Power Supply LEDs LED Meaning INPUT OK 1, INPUT OK 2 Green Source voltage is OK. Input voltage is 85 VAC or greater. (AC-input power supply only) Off Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. INPUT OK 1, INPUT OK 2, Green Source DC voltage is greater than or equal to 40.5 VDC. INPUT OK 3, and INPUT OK 4 Off Source DC voltage is less than or equal to 37.5 VDC. Green, off, or flashing Source DC voltage is between 37.5 and (DC-input power supply 40.5 VDC. only) FAN OK Green Power supply fan is operating properly. Off Power supply fan failure is detected. OUTPUT FAIL Red Problem with one or more of the DC-output voltages of the power supply. Off DC-output voltages within acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal W Power Supply AC Power Cords Table A-36 lists the specifications for the AC power cords that are available for the 6000 W AC-input power supply. Included in the table are references to illustrations of the power cords. TableA W Power Supply AC Power Cords Locale Power Cord Part Number AC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7513ACR= or IRAM A, 250 VAC Figure A-31 CAB-IR2073-C19-AR= Australia, New Zealand CAB-AC-16A-AUS= AU20S3 16 A, 250 VAC Figure A-46 People s Republic of China CAB-AC16A-CH= GB16C 16 A, 250 VAC Figure A-37 Continental Europe CAB-AC-2500W-EU= CEE 7/7 16 A, 250 VAC Figure A-41 International CAB-AC-2500W-INT= IEC A, 250 VAC Figure A-42 Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VAC Figure A-34 Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VAC Figure A-35 A-53
54 8700 W AC-Input Power Supply Table A W Power Supply AC Power Cords (continued) Locale Japan, North America (nonlocking plug) VAC operation Japan, North America (locking plug) VAC operation Power Cord Part Number CAB-AC-2500W-US1= NEMA A, 250 VAC Figure A-43 CAB-AC-C6K-TWLK= NEMAL A, 250VAC Figure A-44 Japan, North America CAB-7513AC= 2 NEMA A, 125 VAC Figure A VAC operation 1 Power Distribution Unit CAB-C19-CBN= IEC C19 16 A, 250 VAC Figure A-47 (PDU) 3 IEC C20 Switzerland CAB-ACS-16= SEV Type A, 250 VAC Figure A The 6000 W power supply operating on two 110 VAC inputs delivers 2900 W. AC Source Plug Type Cordset Rating Power Cord Reference Illustration 2. When operating with VAC, you must use two AC power cords and the power supply output is limited to 2900 W. 3. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector W AC-Input Power Supply Catalyst 6500 series switch support for the 8700 W AC-input (WS-CAC-8700W-E) power supply along with any power supply output restrictions are listed in Table A-37. Table A-37 Chassis Support for the 8700 W Power Supply Catalyst 6500 Series Chassis Catalyst 6506 Catalyst 6506-E Catalyst 6509 Catalyst 6509-E Catalyst 6509-NEB Catalyst 6509-NEB-A Catalyst 6509-V-E Catalyst 6513 Catalyst 6513-E 8700 W Power Supply Restriction Output limited to 4000 W No restrictions Output limited to 4000 W No restrictions Output limited to 4000 W Output limited to 4500 W No restrictions Output is limited to 6000 W No restrictions The 8700 W AC-input power supply, shown in Figure A-18, shares a similar, but not identical, form-factor as the 1000 W, 1300 W, 2500 W, 3000 W, 4000 W, and 6000 W power supplies. A-54
55 8700 W AC-Input Power Supply Note Because of the form-factor difference, when you install an 8700 W power supply in a Catalyst 6506, Catalyst 6509, or Catalyst 6509-NEB chassis you must relocate the system ground connection from the chassis ground pad connection to the two system ground studs located on the 8700 W power supply faceplate. Installing an 8700 W power supply in the other Catalyst 6500 series chassis does not require that you move the chassis system ground connection to the power supply. The 8700 W power supply cannot be installed in the Catalyst 6503, Catalyst 6503-E, and Catalyst 6504-E switch chassis. Figure A-18 Cable retention device 8700 W AC-Input Power Supply System ground studs AC power connection 1 AC power connection 2 AC power connection 3 Power switch Status LEDs o CISCO SYSTEMS, INC. INPUT OK NC RELAY FAN OUTPUT OK FAIL DEFAULT 220VAC NO RELAY Captive installation screw Remote power on/off feature relay switch Remote power on/off feature terminal block 8700 W Table A-38 lists the specifications for the 8700 W AC-input power supply. Table A W AC-Input Specification AC-input type AC-input voltage (One-phase) Description 3 AC-inputs per power supply. High-line input with power factor correction (PFC) included. Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. Low-line (120 VAC nominal) 90 VAC (min) to 132 VAC (max) High-line (230 VAC nominal) 170 VAC (min) to 264 VAC (max) A-55
56 8700 W AC-Input Power Supply Table A W AC-Input (continued) Specification AC-input current AC-input frequency Branch circuit requirement Description 16 A each input 50/60 Hz (nominal) (±3% for full range) Each power supply input should have its own dedicated, fused-branch circuit: For North America 20 A For International Circuits should be sized according to local and national codes All Catalyst 6500 series AC-input power supplies require single-phase source AC. All AC power supply inputs are fully isolated. This means that source AC can be out of phase between multiple AC inputs on the same power supply or different AC power supplies that are installed in the same chassis. For the 8700 W power supply, this means that power cord 1 can be plugged into phases A-B, power cord 2 can be plugged into phases B-C, and power cord 3 can be plugged into phases C-A, A-B, or B-C. A-56
57 8700 W AC-Input Power Supply Table A W AC-Input (continued) Specification Power supply output capacity Description The power supply output capacity is dependent on the number of AC power cords (1, 2, or 3) attached and the source AC voltage (110 VAC [low-line] or 220 VAC [high-line]) applied to the power supply inputs. The 8700 W AC-input power supply is limited to reduced wattage ratings when it is installed in the following Catalyst 6500 series chassis: 4000 W maximum output when it is installed in a Catalyst 6506, Catalyst 6509, or Catalyst 6509-NEB switch chassis W maximum output when it is installed in the Catalyst 6509-NEB-A switch chassis W maximum output when it is installed in the Catalyst 6513 switch chassis. Note The power supply will not power up if you attach only one power cord and the power cord is connected to low-line (110 VAC nominal) source AC W operation 2800 W maximum with the following combinations of power cords and source AC voltage applied to the power supply inputs: Two AC inputs are connected to low-line (110 VAC nominal); the third AC input is not connected. One AC input is connected to low-line (110 VAC nominal); one AC input is connected to high-line (220 VAC nominal); the third AC input is not connected. One AC input is connected to high-line (220 VAC nominal); two AC inputs are not connected W operation 4200 W maximum with the following combinations of power cords and source AC voltage applied to the power supply inputs: All three AC inputs are connected to low-line (110 VAC nominal). Two AC inputs are connected to low-line (110 VAC nominal); one AC input is connected to high-line (220 VAC nominal) W operation 5800 W maximum with the following combinations of power cords and source AC voltage applied to the power supply inputs: Two AC inputs are connected to high-line (220 VAC nominal); the third AC input is connected to low-line (110 VAC nominal). Two AC inputs are connected to high-line (220 VAC nominal); the third AC input is not connected W operation 8700 W maximum with the following combinations of power cords and source AC voltage applied to the power supply inputs: All three AC inputs are connected to high-line (220 VAC nominal). A-57
58 8700 W AC-Input Power Supply Table A W AC-Input (continued) Specification Description Power supply output 2800 W operation VDC VDC VDC 4200 W operation VDC VDC VDC 5800 W operation VDC VDC +42VDC 8700 W operation VDC VDC +42VDC Output holdup time 20 ms minimum kva rating kva Heat dissipation 11, W 16, W 23, W 34, W System power dissipation 10,360 W Weight 39.7 lb (18 kg) 1. The kva rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-39 lists the power supply LEDs and their meanings. A-58
59 8700 W AC-Input Power Supply Table A W AC-Input Power Supply LEDs LED INPUT OK 1, INPUT OK 2, and INPUT OK 3 Meaning Green Source voltage is OK. (Input voltage is 85 VAC or greater.) Off Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. 220VAC 1, 2, and 3 Green High-line AC is present on the respective AC inputs. (Input voltage is 170 VAC or higher.) Off Source AC voltage falls below 170 VAC (running at low-line voltage), is not present, or the power supply is turned off. FAN OK Green Power supply fan is operating properly. Off Power supply fan failure is detected. OUTPUT FAIL Red One or more of the power supply DC-output voltages is out of the normal operating range: For +3.3 VDC output: VDC (min); VDC (max) For +12 VDC output: VDC (min); VDC (max) For +42 VDC output: VDC (min); VDC (max) Off All DC-output voltages are within normal operating ranges. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. A-59
60 8700 W AC-Input Power Supply Remote Power Cycling Feature The 8700 W power supply is equipped with a remote power cycling feature that allows you to remotely turn on or turn off the power supply through an external relay controller box. Figure A-19 shows a typical remote power on/off setup. A three-position terminal block and a switch, located on the lower right quadrant of the power supply faceplate (see Figure A-18), provide the interface to the external relay controller box. Figure A-19 Remote Power On/Off Feature Components 8700 Watt power supply Relay controller Remote power on/off terminal block Relay controller power Network Ferrite bead Terminal Block The terminal block has three contacts labeled 1, 2, and 3. Two control wires from an external relay controller box attach to either positions 1 and 2 or positions 2 and 3. Positions 1 and 2 are used when the relay controller box contains a normally-open (NO) type of relay. Positions 2 and 3 are used when the relay controller box contains a normally-closed (NC) type of relay. Relay Controller Box Switch The relay controller box switch, located next to the terminal block, allows you to match the power supply power control signal s active state with the type of relay contained in the external relay controller box (either a normally-open type of relay or a normally-closed type of relay). Ferrite Bead A plastic bag containing one ferrite bead and two 4-inch plastic ties is included with the 8700 W power supply AC power cords. The ferrite bead is a passive device that limits high-frequency interference on interface and control cables, and is only required when you install the remote power-cycling feature that is supported by the 8700 Watt power supply. The ferrite bead is installed on the two control wires that come from the relay controller box to the terminal block on the 8700 W power supply. The ferrite bead should be installed as close as possible to the power supply terminal block for the bead to be effective. You do not need the ferrite bead for 8700 Watt power supply installations that do not include the remote power-cycling feature. If you need to install the ferrite bead, refer to Installing the Ferrite Bead procedure on page A-60
61 8700 W AC-Input Power Supply Remote Power-Cycling Operation This feature allows you to remotely power cycle the Catalyst 6500 series switch using any appropriate third-party relay controller. This eliminates the need for you to have access to the supervisor engine console or CLI to control power cycling. Table A-40 lists the relay controller box relay type, the corresponding power supply terminal block positions, and a description of the power-cycling operation. Table A W Power Supply Relay Controller Switch Settings and Operation External Relay Controller Box Relay Type Normally open (NO) relay. Normally closed (NC) relay. No relay attached. Remote power-cycling feature not installed. Power Supply Relay Controller Switch Setting NO RELAY (DEFAULT) NC RELAY NO RELAY (DEFAULT) Power Supply Terminal Block Positions Used Control wires from the external relay controller box attach to terminal block positions 1 and 2. Control wires from the external relay controller box attach to terminal block positions 2 and 3. Remote Power-Cycling Operation Power supply cycled from on to off The power supply is powered off by energizing the relay (relay contacts go from open to closed) for more than 30 seconds. Power supply cycled from off to on The power supply is powered on by deenergizing the relay (relay contacts go from closed to open) for more than 10 seconds. Power supply cycles from on to off The power supply is powered off by energizing the relay (relay contacts go from closed to open) for more than 30 seconds. Power supply cycles from off to on The power supply is powered on by deenergizing the relay (relay contacts go from open to closed) for more than 10 seconds. A-61
62 8700 W AC-Input Power Supply 8700 W Power Supply AC Power Cords Table A-41 lists the specifications for the AC power cords that are available for the 8700 W AC-input power supply. Included in the table are references to illustrations of the power cords. TableA W Power Supply AC Power Cords Locale Power Cord Part Number AC Source Plug Type Cordset Rating Power Cord Reference Illustration Argentina CAB-7513ACR= or IRAM A, 250 VAC Figure A-31 CAB-IR2073-C19-AR= Australia, New Zealand CAB-AC-16A-AUS= AU20S3 16 A, 250 VAC Figure A-46 People s Republic of China CAB-AC16A-CH= GB16C 16 A, 250 VAC Figure A-37 Continental Europe CAB-AC-2500W-EU= CEE 7/7 16 A, 250 VAC Figure A-41 International CAB-AC-2500W-INT= IEC A, 250 VAC Figure A-42 Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VAC Figure A-34 Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VAC Figure A-35 Japan, North America (nonlocking plug) VAC operation CAB-AC-2500W-US1= NEMA A, 250 VAC Figure A-43 Japan, North America (locking plug) VAC operation Japan, North America VAC operation Power Distribution Unit (PDU 2 CAB-AC-C6K-TWLK= NEMAL A, 250VAC Figure A-44 CAB-7513AC= 1 CAB-C19-CBN= NEMA A, 125 VAC Figure A-36 IEC C19 IEC C20 16 A, 250 VAC Figure A-47 Switzerland CAB-ACS-16= SEV Type A, 250 VAC Figure A When operating with VAC, you must use two or three AC power cords and the power supply output is limited to either 2800 W (2 inputs) or 4200 W (3 inputs). 2. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. A-62
63 AC Power Cord Illustrations AC Power Cord Illustrations This section contains the AC power cord illustrations (see Figures A-19 through A-48). An AC power cord may be used with several power supplies. See the power supply specifications tables for the AC power cord illustrations that are applicable for your power supply. Figure A-20 CAB-AC10A-90L-AU= (Australia and New Zealand) Plug: SAA AS 3112 Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC C Figure A-21 CAB-AC10A-90L-EU= (Continental Europe) Plug: CEE 7/7 Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC C A-63
64 AC Power Cord Illustrations Figure A-22 CAB-AC10A-90L-IT= (Italy) Plug: CEI 23-16/7 Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC C Figure A-23 CAB-AC15A-90L-US= (Japan and United States) Plug: NEMA 5-15 Cordset rating: 15 A, 125 V Length: 8 ft 2 in. (2.5 m) Connector: IEC C Figure A-24 CAB-AC10A-90L-UK= (United Kingdom) Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) 13 A fuse Plug: BS 1363 Connector: IEC C A-64
65 AC Power Cord Illustrations Figure A-25 CAB-7KACR= (Argentina) Plug: IRAM 2073 Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC C Figure A-26 CAB-7KACA= (Australia and New Zealand) Plug: SAA AS 3112 Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC C Figure A-27 CAB-7KACE= (Continental Europe) Plug: CEE 7/7 Cordset rating: 16 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC C A-65
66 AC Power Cord Illustrations Figure A-28 CAB-7KACI= (Italy) Plug: CEI 23-16/7 Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC C Figure A-29 CAB-7KAC-15= (Japan and United States) Plug: NEMA 5-15 Cordset rating: 15 A, 125 V Length: 8 ft 2 in. (2.5 m) Connector: IEC C Figure A-30 CAB-7KACU= (United Kingdom) 13A fuse Plug: BS 1363 Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC C A-66
67 AC Power Cord Illustrations Figure A-31 CAB-7513ACR= and CAB-IR2073-C19-AR= (Argentina) Plug: IRAM 2073 Cordset rating: 10 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C Figure A-32 CAB-7513ACA= (Australia and New Zealand) Plug: SAA AS 3112 Cordset rating: 15 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C Figure A-33 CAB-7513ACE= (Continental Europe) Plug: CEE 7/7 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C A-67
68 AC Power Cord Illustrations Figure A-34 CAB-AC-2500W-ISRL (Israel) Plug: SI16S3 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C Figure A-35 CAB-7513ACI= (Italy) Plug: CEI 23-16/7 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C Figure A-36 CAB-7513AC= (Japan and United States) Plug: NEMA 5-20 Cordset rating: 20 A, 125 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C A-68
69 AC Power Cord Illustrations Figure A-37 CAB-AC16A-CH= (People s Republic of China) Plug: GB16C Cordset rating: 16A, 250V Length: 14 ft 0 in. (4.26 m) Connector: IEC C Figure A-38 CAB-7513ACSA= (South Africa) Plug: IEC 884 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C Figure A-39 CAB-ACS-10= (Switzerland) Plug: SEV 1011 Cordset rating: 10 A, 250 V Length: 7 ft 0 in. (2.13 m) Connector: IEC C A-69
70 AC Power Cord Illustrations Figure A-40 CAB-7513ACU (United Kingdom) Plug: BS A replaceable fuse Cordset rating: 13 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C Figure A-41 CAB-AC-2500W-EU (Continental Europe) Plug: CEE 7/7 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C Figure A-42 CAB-AC-2500W-INT= (International) Plug: IEC 309 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C A-70
71 AC Power Cord Illustrations Figure A-43 CAB-AC-2500W-US1= (Japan and United States) Plug: NEMA 6-20 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C Figure A-44 CAB-AC-C6K-TWLK= (Japan and United States) Plug: NEMA L6-20 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C19 TURN & PULL Alternate plug: NEMA L6-20 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C19 The form factor for these two plugs differ but functionally they are the same A-71
72 AC Power Cord Illustrations Figure A-45 CAB-ACS-16= (Switzerland) Plug: SEV Type 23 Cordset rating: 16 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC C Figure A-46 CAB-AC-16A-AUS= (Australia and New Zealand) Plug: AU20S3 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Connector: IEC C Figure A-47 CAB-C19-CBN= (PDU) Connector: IEC C20 Cordset rating: 16 A, 250 V Length: 9 ft 0 in. (2.7 m) Connector: IEC C A-72
73 Power Supply Redundancy Figure A-48 WS-CAC-4000W-INT= (International) Cordset rating: 32 A, 250 V Length: 12 ft 0 in. (3.65 m) Hardwired to power supply Plug: IEC Figure A-49 WS-CAC-4000W-US= (United States) Plug: NEMA L6-30 Cordset rating: 30 A, 250 V Length: 12 ft 0 in. (3.65 m) Hardwired to power supply Power Supply Redundancy Catalyst 6500 series switching modules have different power requirements. Depending upon the wattage of the power supply, certain switch configurations might require more power than a single power supply can provide. Although the power management feature allows you to supply power to all installed modules with two power supplies, redundancy is not supported in this configuration. Redundant and combined power configurations are summarized in Table A-42. The effects of changing the power supply configurations are summarized in Table A-43. Note For proper load-sharing operation in a redundant power supply configuration, you must install two modules in the chassis. If you fail to install two modules, you might receive spurious OUTPUT FAIL indications on the power supply. Note In systems that have two different sized power supplies installed, you may not have true redundancy. If the larger wattage power supply fails, the smaller wattage power supply might not be able to handle the entire load by itself. A-73
74 Power Supply Redundancy Table A-42 Power Supply Redundancy If you have two and redundancy is Then power supplies of Equal wattage Enabled The total power drawn from both supplies is never greater than the capability of one supply. If one supply malfunctions, the other supply can take over the entire system load. Each power supply provides approximately half of the required power to the system. Load sharing and redundancy are enabled automatically; no software configuration is required. Unequal wattage Enabled Both power supplies initially come online. For the Catalyst operating system, if the difference between the two power supply s output wattage is less than 10 percent of the higher output wattage power supply, redundancy is enabled. If the difference is greater than 10 percent, the lesser wattage power supply is disabled. For Cisco IOS, both power supplies come on. The total available wattage is the output wattage of the higher wattage power supply. Equal or unequal wattage Disabled The total power available to the system is approximately 167 percent of the lower-wattage power supply. The system powers up as many modules as the combined capacity allows. If the higher-wattage power supply fails, the lower-wattage supply might also shut down due to overcurrent protection to prevent damage to the lower-wattage power supply. Table A-43 Effects of Power Supply Configuration Changes Configuration Change Effect Redundant to combined System log and syslog messages are generated. System power is increased to approximately 167 percent of the lower-wattage power supply. The modules marked as power-deny in the show module Status field are powered up if there is sufficient power. Combined to redundant System log and syslog messages are generated. System power is the power capability of the higher-wattage supply. If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in the show module Status field. Equal wattage power supply is inserted with redundancy enabled System log and syslog messages are generated. System power equals the power capability of one supply. (Both supplies provide approximately one half of the total current.) No change in the module status because the power capability is unchanged. A-74
75 Power Supply Redundancy Table A-43 Effects of Power Supply Configuration Changes (continued) Configuration Change Equal wattage power supply is inserted with redundancy disabled Higher wattage power supply is inserted with redundancy enabled Lower wattage power supply is inserted with redundancy enabled Higher or lower wattage power supply is inserted with redundancy disabled Power supply is removed with redundancy enabled Power supply is removed with redundancy disabled Effect System log and syslog messages are generated. System power is the combined power capability of both supplies. The modules marked as power-deny in the show module Status field are brought up if there is sufficient power. System log and syslog messages are generated. The system disables the lower-wattage power supply; the higher-wattage supply powers the system (Catalyst operating system). For Cisco IOS, both power supplies come on. The total available wattage is the output wattage of the higher wattage power supply. System log and syslog messages are generated. The system disables the lower-wattage power supply; the higher-wattage supply powers the system (Catalyst operating system). For Cisco IOS, both power supplies come on. The total available wattage is the output wattage of the higher wattage power supply. System log and syslog messages are generated. System power is increased to the combined power capability of both supplies. The modules marked as power-deny in the show module Status field are brought up if there is sufficient power. System log and syslog messages are generated. If the power supplies are of equal wattage, there is no change in the module status because the power capability is unchanged. If the power supplies are of unequal wattage and the lower-wattage supply is removed, there is no change in the module status. If the power supplies are of unequal wattage and the higher-wattage supply is removed, the lower-wattage power supply must be turned on manually. (The system had previously turned off the lower-wattage power supply.) System log and syslog messages are generated. System power is decreased to the power capability of one supply. If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in the show module Status field. A-75
76 Power Supply Redundancy Table A-43 Effects of Power Supply Configuration Changes (continued) Configuration Change System is booted with power supplies of different wattage installed and redundancy enabled System is booted with power supplies of equal or different wattage installed and redundancy disabled Effect System log and syslog messages are generated. The lower-wattage supply is disabled (Catalyst operating system). For Cisco IOS, both power supplies come on. The total available wattage is the output wattage of the higher wattage power supply. System log and syslog messages are generated. System power equals the combined power capability of both supplies. The system powers up as many modules as the combined capacity allows. When running redundant 4000 W, 6000 W, or 8700 W power supplies in Catalyst 6506 and Catalyst 6509 non-e series systems, if you remove the power supply in bay 1, the total system power will be reduced to 2940 W (70 A at 42 VDC) after 180 seconds (3 minutes). You can avoid this reduction in the total system power by leaving the power supply in bay 1, even in a powered down state. If the total system power usage is greater than 2940 W, the following scenario will apply if a 4000 W, 6000 W, or a 8700 W power supply is removed from bay 1 (these scenarios are specific to only these three power supplies running in redundant mode in either the Catalyst 6506 or Catalyst 6509 non-e series systems). If the power supplies in bay 1 and bay 2 are running in redundant mode, the total system power will be 4000 W. If power supply 1 is running and you power off or remove power supply 2, the total system power will be 4000 W. The system will issue a normal power supply 2 down/remove indication warning. If you power down power supply 1 while power supply 2 is operating, the system will issue a normal power supply 1 down indication warning with another warning asking the user not to remove power supply 1. If power supply 1 is left in the system, even if it is powered off, the total system power will be 4000 W. If you remove power supply 1 from the system, a major alarm will be issued to warn that the total system power will be reduced to 2940 W and that any modules or PoE devices that cause the system to exceed 2940 W will power down in 180 seconds (3 minutes). If you insert a replacement power supply 1 in the 180-second timeframe, no action will be taken. A-76
77 Power Supply Redundancy Note In systems that are equipped with two power supplies, if one power supply fails and the other power supply cannot fully power all of the installed modules, system power management will shut down devices in the following order: Power over Ethernet (PoE) devices The system will power down PoE devices in descending order, starting with the highest numbered port on the module in the highest numbered slot. Modules If additional power savings are needed, the system will power down modules in descending order, starting with the highest numbered slot. Slots containing supervisor engines or Switch Fabric Modules are bypassed and are not powered down. This shut down order is fixed and cannot be changed. You can change the configuration of the power supplies to redundant or combined at any time. If you switch from a redundant to a combined configuration, both power supplies are enabled (even a power supply that was disabled because it was of a lower wattage than the other power supply). If you change from a combined to a redundant configuration, both power supplies are initially enabled, and if they are of the same wattage, they remain enabled. If they are of different wattage, a syslog message displays and the lower wattage supply is disabled. For additional information about the power management feature and individual module power consumption, refer to your software configuration guide. A-77
78 Power Supply Redundancy A-78
Cisco Nexus 7000 Series Power Supply Modules
Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable
Extending Performance, Versatility, and Reliability at the Provider Edge
Cisco 7604 Chassis Extending Performance, Versatility, and Reliability at the Provider Edge Cisco 7604 Router The Cisco 7604 Router is a compact, high-performance router designed in a 4-slot form factor
6000 WATT AC POWER SUPPLY FOR THE CISCO CATALYST 6500 SERIES CHASSIS
DATA SHEET 6000 WATT AC POWER SUPPLY FOR THE CISCO CATALYST 6500 SERIES CHASSIS PRODUCT OVERVIEW The 6000-watt (W) power supply for the Cisco Catalyst 6500 Series chassis (Figure 1) is a dual AC input
Cisco Redundant Power System 2300
Cisco Redundant Power System 2300 The Cisco Redundant Power System 2300 (RPS 2300) increases availability for converged data, voice, and video networks. The system delivers power supply redundancy and
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: [email protected] www.juicegoose.com 06-06 CONGRATULATIONS
Server Technology, Inc.
Server Technology, Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2009-April-07 Headquarters Server Technology, Inc. 1040 Sandhill
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
MAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual
ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) User Manual Table of Contents 1 Introduction 2 General specification 3 Installation 4 Pin assignment & function of connectors 5 Drawing
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
Three-Phase Electric Power Distribution for Computer Data Centers
Three-hase Electric ower Distribution for Computer Data Centers WHITE AER E901 Geist January 008 Summary This paper will describe the characteristics of three-phase power and outline the advantages of
Antec TruePower User's Manual
User s Manual Antec TruePower User's Manual Antec TruePower ATX12V power supply Models: TRUE330, TRUE380, TRUE430, TRUE480, TRUE550 Antec Low Noise Technology: The Antec TruePower power supply is equipped
8800 Series 100-240VAC PSU XCM88PS1
8800 Series 100-240VAC PSU XCM88PS1 Hardware Installation Guide 350 East Plumeria Drive San Jose, CA 95134 USA February 2011 201-13472-02 1.0 2011 NETGEAR, Inc. All rights reserved. No part of this publication
Cisco Catalyst 4500E Series Power over Ethernet Capabilities and Power Supplies
Data Sheet Cisco Catalyst 4500E Series Power over Ethernet Capabilities and Power Supplies Power over Ethernet on the Cisco Catalyst 4500E Series Platform The Cisco Catalyst 4500E Series platform offers
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
Increasing Data Center Efficiency by Using Improved High Density Power Distribution
Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Executive Summary A new approach to power distribution for high density server installations
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
Contractors Guide Central Inverter System Installation
Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.
Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
Intel Server System S7000FC4UR
Intel Server System S7000FC4UR Power Cord Enabling Specification January, 2007 Enterprise Platforms and Services Division - Marketing Intel Server System S7000FC4UR Power Supply Specification Revision
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac
Product Description Capacitor charger power supplies from Digital Power are designed to meet the exacting requirements of medical, aesthetic, and industrial pulsed energy systems. The modular design of
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Edition Perfect combination 9 Power supplies Electronic P Edition kaging www clear order..biz information in the catalogue
9 Power supplies Übersicht PROLINE Overview... 0 Power supplies Cabinets... 1 Wall mounted cases... 2 slimpower AC/DC switched-mode power supply 42 W, 3 HP Compact and low interference Accessories for
Applied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets MODEL NUMBER: BC600SINE Highlights 600VA tower 120V standby UPS with SINE WAVE output Maintains AC output during power
Model #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:
SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the
Intersection Preassembled 19-inch Rack
Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1000RT2U Highlights 1kVA / 1000VA / 900W line-interactive 2U rack/tower UPS, Sine
5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions
TM 5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions Document Number 9000-A2-GN17-30 August 1998 Before You Begin Both the 5-slot housing and the FrameSaver
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Distributing Power to Blade Servers
Distributing Power to Blade Servers Ten steps to selecting the optimal power distribution design With the growth in blade servers with dual or triple power supplies, a single rack of equipment can easily
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
Cable Specifications. T3 Trunk Cabling APPENDIX
APPENDIX B This appendix contains details on the MGX 8230 cabling. It includes the following sections: T3 Trunk Cabling Frame Relay Cabling DC Power Cabling AC Power Cabling Control and Clock Cabling External
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
APC 3Phase Power Distribution
APC 3Phase Power Distribution North American 3 Phase Business Development Team All content in this presentation is protected 2008 American Power Conversion Corporation Objectives Understand the entire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
Handheld portable appliance testers
PAT100 SERIES Handheld portable appliance testers PAT100 SERIES Handheld portable appliance testers Simple Tick/Cross, pass/fail indication plus measurement Battery powered with rechargeable options Includes
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
INSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings
*** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
HP 2530 8-Port Switches Quick Setup Guide
HP 2530 8-Port Switches Quick Setup Guide The switch drawings in this document are for illustration only and may not match your particular switch model. For more detailed instructions and information to
Table of Contents. TransformerIQ FAQs 1
[12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,
T1 Backhaul Connectivity Solution All Products :: Application Note
Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments
QuickSpecs. HP 480/277 Volt Solutions. Overview
Overview As the quest for efficiency continues it becomes apparent that what worked in the past needs improvement. More and more data center managers are looking at alternate power plans to distribute
Continuous Power... Continuous Protection
Series 165 We Keep Your Power On Continuous Power... Continuous Protection An Automatic Transfer Switch helps prevent... Your business or home from losing power during bad weather or utility power equipment
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers
Technical Note Freedom/Fleet Power 512-0084-01-01 Rev 1 Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers Overview This document is a guide for troubleshooting inverters, battery chargers,
Operating Manual UWAPS-TINY Series
Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,
Fundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
High-Efficiency AC Power Distribution for Data Centers
High-Efficiency AC Power Distribution for Data Centers White Paper 128 Revision 2 by Neil Rasmussen > Executive summary The use of 240 volt power distribution for data centers saves floor space, simplifies
PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS
PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000
Refer installation of power supplies to qualified service personnel.
AC Power Supply For 5-Slot Housing and 9000 Series Access Carrier Installation Instructions Document Number 9000-A2-GN17-50 August 2000 Before You Begin Both the 5-slot housing and the 9000 Series Access
in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.
600KW - 1250KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control High capacity, 600-1250kw Dual voltage: 208-240/416-480vAC Digital load control, 5 kw
Model Number Electrical Compatibility Module Connector Type. M250-60-2LL-S22 60 cell PV module MC-4 Type 2 Locking
TECHNICAL BRIEF M250 Microinverter System Installation Planning The M250 Microinverter The Enphase M250 Microinverter is a powerful and efficient grid-tied microinverter. It is compatible with most 60-cell
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Power Distribution Considerations for Data Center Racks
Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical
LOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual
Infrastructure Management & Monitoring For Business-Critical Continuity Liebert icom-do User Manual TABLE OF CONTENTS 1.0 INTRODUCTION............................... 1 2.0 INSTALLATION...............................
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port MODEL NUMBER: OMNIVS1500 Highlights 1500VA / 1.5kVA tower 120V line-interactive UPS Corrects brownouts and overvoltages from 75 to 147V
QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview
Overview HP Modular PDUs have a unique modular architecture designed specifically for data center customers who want to maximize power distribution and space efficiencies in the rack. Modular PDUs consist
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description
VLT Series 300 Watt True Sine Wave Inverter
VLT Series 300 Watt True Sine Wave Inverter PURE SINE WAVE INVERTER I ON 0 OFF REMOTE CONTROL AC OUTPUT POWER STATUS Vout Vin Models VLT12-300 VLT24-300 300 Watt VLT Series Inverter - 1 - TABLE OF CONTENTS
AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5
AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Cisco 7200 Series. Product Overview. Key Features and Benefits
Cisco 7 Series Product Overview Cisco 7 series routers are designed for today s most mission-critical internetworks because they combine Cisco Systems proven software technology with reliability, availability,
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial MODEL NUMBER: SMART1500SLT Highlights 1.5kVA / 1500VA line interactive tower UPS; Sine wave output
Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V
SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
NV-EC1701. Ethernet over Coax Transceiver www.nvt.com (+1) 650.462.8100 (+44) (0) 208 977 6614. Model NV-EC1701
EoC Ethernet over Coax Transceiver with PoE+ Data Sheet Application Example: IP Camera Cat5 100m ( 328ft) NV-EC1701 Ethernet over Coax Transceiver www.nvt.com (+1) 650.462.8100 (+44) (0) 208 977 6614 Coax
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
USER MANUAL Online UPS 1K/2K/3K Rack
USER MANUAL EN Online UPS 1K/2K/3K Rack Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation 2
Research RF Sputtering Packages
Research RF Sputtering Packages Shown with 3" Polaris Adjustable Position Source with Tilt and Shutter 300 or 600 Watt Low Cost Packages for Those With Limited Budgets Desiring Full Capability 13.56 MHz
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
Back-UPS Pro 1300/1500 Installation and Operation
Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black
USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-
The power module is Feature Number 8800-F2-901.
Hotwire 8820 GranDSLAM AC to DC Power Supply Installation Instructions Document Number 8800-A2-GZ41-00 AC to DC Power Supply The AC to DC Power Supply consists of a power supply chassis and one or two
OWNER'S MANUAL. Model 20-1050CUL AC Power Inverter/Charger System OM/A96283 REV. A
OWNER'S MANUAL Model 20-1050CUL AC Power Inverter/Charger System OM/A96283 REV. A Table of Contents Section 1 Introduction... 1 Section 2 Installing the 20-1050CUL... 4 Section 3 Installing the IFM1 Interface
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
F(t) Forssell Technologies Inc
F(t) Forssell Technologies Inc SMP-2Aa Microphone Preamplifier User Manual Forssell Technologies Inc Sandpoint Idaho USA (208) 263-0286 Introduction The Forssell Technologies Inc SMP-2A is a 2 channel,
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault