The following components are common to most cubicles; this example is an ABB HK cubicle.



Similar documents
Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

01.4IB.51200B PowlVac-AR Arc Resistant Switchgear. 5kV & 15kV 1200A, 2000A, 3000A, & 4000A Forced Cooled. Powered by Safety

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Switchgear and Metal-Enclosed Bus

Low Voltage Switchgear

Extend the Life of Existing Switchgear

Sample - No Commercial Use

Vacuum Circuit Breaker Type VAD-3

How To Build A Germany Power Plant

Bypass transfer switch mechanisms

Medium voltage VCP-W MR2 (integral racking)

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Masterclad 5 15 kv Arc Resistant Metal-Clad Indoor Switchgear

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

The Intelligent AX1 Switchgear for Medium Voltage

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Power Plant Electrical Distribution Systems

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

How to reduce exposure to arc flash hazards

Advantages of Fixed Circuit Breaker Switchgear

PowlVac Type PVDST Replacement Vacuum Circuit Breaker Replacement for Federal Pacific Type DST Air-Magnetic Circuit Breakers

Power IT MV Air Insulated Switchgear. Technical Information and Application Guide Featuring Advance TM and SafeGear TM Technology

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Unified requirements for systems with voltages above 1 kv up to 15 kv

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Addendum #2 Contract UK-11-13

2008 Eaton Corporation. All rights reserved.

Houston Service Center Medium Voltage Service and Aftermarket Solutions

PIP ELSSG02 Design and Fabrication of Medium Voltage Metal-Clad Switchgear from 4.76 kv to 38 kv

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

15VHK-VR Model 20 Replacement Circuit Breaker

GEK-90214B. GE Lift Truck. User s Guide 144D2933G1 144D2912G1 144D2911G5

IB PowlVac-ND ITE-HK 5kV Replacement Vacuum Circuit Breaker. Replacement for ABB Type ITE-HK Air Circuit Breaker.

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

Understanding Emergency Power Off (EPO)

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

Instructions for Magnum DS T

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Utility generation line card

Power/Vac Metal-Clad Switchgear and Vacuum Circuit Breakers Maintenance and Troubleshooting Suggestions

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

Enhancing Personnel Safety with Arc Resistant Equipment

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

LVA Take Offs in Bid Manager

CAPACITOR BANK TESTING SWP

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

Medium Voltage Switchgear

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

DOCUMENT ADDENDUM NO. 2. Issued to all Bidders: Date: February 3, Contract Name: 13,800-Volt and 480-Volt Switchgear

Primary and Secondary Electrical Distribution Systems

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

DC400 Dispensing Cutoff System

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

WE-350 Series ¼ Turn Electric Actuator

A Comparison of Contemporary Electrical Distribution Equipment Standards. San Francisco IEEE Industry Applications Society May 26, 2009

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Relay mounting systems

Part 1 System Modeling & Studies for Existing Systems

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT NETWORK SYSTEMS SECTION

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Current Transformers Ratio / Polarity / Types

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

01.4IB.66000B Power/Vac Vacuum Circuit Breaker. Equipped with ML-17 or ML-17H Mechanism. Powered by Safety

Hyperlinks are Inactive

Instructions for Installation, Operation and Maintenance of 24kV Type W-VAC Vacuum Circuit Breaker

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

SENTRON Switching and Protection Devices Air Circuit Breakers

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Oil and Coolant Circulating Heating System. Model - OCSM

MCC Ratings. Voltage Rating

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

MNS Low Voltage Switchgear System Guide

Product Guide. Low voltage grounding system. Answers for industry.

Customer Substation Manual 08/05/02

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

Transcription:

4.0 CIRCUIT BREAKER CUBICLE Learning Objectives The circuit breaker cubicle is the component of the switchgear that holds the circuit breaker, and the controls and cabling for the distribution system. As a result of this lesson you will be able to: 1. Understand the components of the cubicle 2. Understand the function of the shutter assembly 3. Describe the positions of a breaker during the racking operation 4. Understand and explain the test position 5. Explain the function of the truck-actuated switch 6. Understand the operation of the mechanism operated Switch 4.1 WHY CIRCUIT BREAKERS ARE REMOVABLE The circuit breaker is removed from the cubicle to allow for the complete isolation of loads from sources, for personnel safety during component maintenance, and for repair. Circuit breakers of the same rating are generally interchangeable; allowing an alternate circuit breaker to be installed while the original is maintained. When a circuit breaker is removed for system repairs a ground truck may be installed in the compartment to connect the de-energized equipment to ground. The ground truck is a breaker frame with bushings only and a ground bus, the bus side is run to ground and with the truck in the breaker position there is no danger of energizing the circuit. 4.2 MEDIUM VOLTAGE BREAKER CELL COMPONENTS The following components are common to most cubicles; this example is an ABB HK cubicle. Shutter: the fiberglass barrier that isolates the live bus connections to the cell (Figure 4-1). USNRC 4-1 Rev 0

Primary Disconnects: the disconnects that connect the power to the breaker (Figure 4-3). Secondary Disconnects: the disconnects that connects the control power (Figure 4-2.) Guide rail: the rail that guides the breaker into the cell (Figure 4-5). Ground Bar: the ground connecting point to the breaker frame (Figure 4-2). CT s: current transformers located on the primary bus. Transform the current down to a manageable value for instrumentation (Figure 4-4). Instrumentation Relays: relays mounted in the door of the cell that monitor the voltage and current. Rejection Plate: prevent racking the wrong breaker into the cubicle (Figure 4-2). Breaker Positions: markings that show position of the breaker, such as, connected, disconnected and testing (Figure 4-5). 4.3 SWITCHGEAR AUXILIARY SWITCHES (figure 4-6) A number of different types of auxiliary switches are used to indicate the position of the circuit breaker contacts and readiness of the circuit breaker for operation and also to provide additional electrical interlocks. These are mechanism operated and truck operated auxiliary switches. 4.3.1 Mechanism-Operated Control Auxiliary Switches (MOC switch) MOC switches are operated directly from the breaker mechanism some switches are mounted on the circuit breaker but normally they are mounted in the switchboard enclosure and linked mechanically to the circuit breaker. Figure 4-6 shows a common MOC arrangement on a Westinghouse DHP cubicle. USNRC 4-2 Rev 0

4.3.2 Truck-Operated Contact Auxiliary Switches (TOC switch) TOC auxiliary switches are mounted in the circuit breaker compartment and operate when the circuit breaker is moved to the operating position. TOC switches may be used for interlocking and remote position indication. 4.4 INTERNAL CONTROL WIRING The circuit breaker control wiring originates at the secondary disconnects and terminates at meters, relays, and control circuits. 4.5 RACKING INTERLOCKS All breakers have interlocks on the racking mechanism or in the switchboard to prevent the breaker being racked in or out when closed. These interlocks will trip the breaker if a close operation is attempted while racking the breaker in or out. The interlock will also prevent insertion of the racking tool until the breaker is tripped. 4.6 RACKING POSITIONS A racking mechanism also called a levering device is the mechanism used to insert and remove the circuit breaker from the circuit breaker compartment. Most circuit breakers are racked in manually by a racking tool, which looks like a large speed wrench with a special end to fit on to the breaker-racking device (Figure 4-5). The general electric vertical lift Magne-Blast breakers are racked in by an electric racking motor but can also be inserted with a manual-racking handle. The racking operation is potentially one of the most dangerous breaker evolutions; if the breaker safety interlocks fail the breaker can explode. Because of this danger many plants are starting to use remote racking systems to perform the breaker racking operation. All circuit breakers have two main positions connect and disconnect, some breakers also have a test and a withdrawn position. Disconnect Position: In this position the breaker is completely off the bus and disconnected from the secondary disconnect. The breaker should be able to be removed from the cubicle but may need to have a latch holding it in this position. USNRC 4-3 Rev 0

Connect Position: In this position the breaker primary and secondary disconnects are completely inserted and control power is available to the breaker. Test Position: The definition of the test position is the primary disconnects are disconnected from the cubicle bus, and the secondary disconnect is connected and control power is available to operate the breaker. In this position the breaker can be operated electrically to verify operation but since the bus is not connected the equipment will not be energized. Withdrawn Position: Circuit breakers with racking mechanism as part of the breaker may have a position beyond disconnect. In this position the racking mechanism interlocks the mechanism and puts the breaker in a locked out position where the close and trip latch is engaged. 4.7 RACKING SHUTTER The racking shutter is a mechanism, which covers the cubicle side primary bus when the breaker is racked out and removed. The shutter prevents easy access to the live portion of the cubicle bus work when the breaker is removed from the switchboard. As the breaker is racked into the cubicle a roller or shaft will engage the shutteractuating arm and lift the shutter from the primary bus opening. When removing the breaker the shutter will re-close and cover the primary opening. USNRC 4-4 Rev 0

Medium Voltage Circuit Breaker Course Chapter 4.0 SHUTTER Figure 4-1 Shutter assembly Secondary Disconnect Rejection Plate Ground Bus Figure 4-2 Stationary secondary disconnect USNRC 4-5 Rev 0

Medium Voltage Circuit Breaker Course Chapter 4.0 Primary Disconnects FIGURE 4-3 HK Primary disconnects Figure 4-4 Instrumentation current transformers USNRC 4-6 Rev 0

Guide Rails Position Indication Figure 4-5 Position indication and guide rails USNRC 4-7 Rev 0

Medium Voltage Circuit Breaker Course Chapter 4.0 Figure 4-6 Westinghouse DHP - MOC and TOC Switches USNRC 4-8 Rev 0