Flexible and safe solutions, for decades. Cables for alarmand safety systems
2 We offer the widest range of cables on the market for every kind of installation.
It s all about reliability. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant details can make a big difference in terms of ease of handling, functionality and service life. We have the cables you are looking for We offer the widest range of cables on the market for every kind of installation. The cables we supply carry signals and power supplies. For extra peace of mind concerning fire protection, our cables are available in versions meeting specified fire safety requirements in installations. Halogen free for greater safety We have decided only to include halogen free cables in this brochure. There is a clear trend in that direction, and there is no longer any reason for not choosing halogen free cables. Halogen free cables offer many advantages in particular, they make it easier to escape the building in the event of fire, generating substantial savings in the long run. 100 years of experience thrown in At Nexans we research, develop and manufacture cables for the whole world. For different environments and climates. And we ve been doing it for more than a hundred years. So when you choose our cables, they come with a whole lot more our dedication and all the experience and expertise we ve built up over the decades. 3
Product segments Video surveillance (CCTV) Locally installed CCTV (closed circuit TV) systems are increasingly being used as a crime prevention tool. In addition to standardized coaxial cable, Nexans also supplies cables with separate power supply and a data cable for IP based solutions outdoor. Fire alarms Detector networks often occupy large volumes so cables must be easy to install. Nexans cables are easy to strip and are optimised to simplify installation in pipes. Choose from simple, non twisted pair cables for small conventional systems and twisted pair cables for larger addressable systems. The cables used in fire alarm detector networks should normally have a red sheath. If the cables are required to keep working during a fire, you should use Nexans Alsecure (see page 12 Performance during a fire ). 4
Performance during a fire There is a separate fire class for cables that are required to maintain sircuit integrity during a fire. These cables all have unique insulation material that is not damaged like normal cables. This category can include power supply cables as well as signal cables. They should also be flame retardant low fire hazard cables in other words they must not give off any toxic or corrosive gases, and only small amounts of smoke, if there is a fire. Access protection Burglar alarms usually have a system of control units and sensors. Indoor and outdoor entry systems contain card readers, central units and computers. The cables used for intruder protection and entry control are signal cables with varying flexibility, shielding and cores. Alternatively, combination cables can be used with separate cores carrying the power supply. Nexans wide range makes it easy to choose the right cables for the various components. The Nexans cables for these applications are called Alsecure. The unique insulation (INFIT ) makes the cables easy to install while ensuring they still work during a fire. 5
Video surveillance (CCTV) CCTV (Closed Circuit TeleVision) is a locally installed video surveillance system. A CCTV system consists of cameras, monitors, transmission elements (cables), control systems and storage systems. Our range of halogen free cables for CCTV includes 75 ohm coaxial cable. We also offer a combined coax and power supply cable to optimise functionality as well as cable laying. RG 59 LSZH Coaxial cable for video surveillance. The impedance of the cable: 75 ohm. RG 59 LSZH 19502641 6,1 mm Bobbin/100 RG 59 LSZH 19502671 6,1 mm Bobbin/500 RG 59 LSZH + 2 x 0,75 mm 2 Combined coaxial (75 ohm) and power supply cable (max. 100V) for video surveillance. RG 59 LSZH + 2 x 0,75 mm 2 19503098 9,5 mm Drum/500 For added safety, video surveillance cables are also flame retardant and halogen free. 6
S/FTP Category 6A LSZH + PE LANmark Industry outlet IP67 The LANmark Industry outlet enables the installation of data outlets in exposed areas as well as outdoor solutions. The IP67 level of protection is maintained both when the outlet is nused and when the appropriate IP67 patchcords are connected. Includes 2 screened category 6 or category 6A connectors. Cable Nexans no IP67 outer with RJ45 cat.6 shielded Snap-in connector, black. 40060109 IP67 outer with RJ45 cat.6a shielded Snap-in connector, black. 40061009 IP67-IP20 cabling 1,5 m shielded, yellow. Cat.6 RJ45. 40060209 IP67-IP20 cabling 3 m shielded, yellow. Cat.6 RJ45. 40060309 IP67-IP20 cabling 5 m shielded, yellow. Cat.6 RJ45. 40060409 Category 6A, 500 MHz Screened data cable. The 4 pairs are individually foiled and covered with a common braid. Due to the outer sheath of PE the cable is appropriate for outdoor installation as well as in exposed areas. It can be installed indoors when the PE sheet is removed. The cable fulfills cat 6A performance according to EN 50288, IEC 61156 and TIA 568-B Cable Nexans no Outer diam. Length Category 6A 4x2x0,5 39020771 8,6 B/500 7
8 Find out more about fire safety and fire classes.
You often won t know whether you chose the right cable until after a fire. People always talk about fire protection but it is important to know what this actually means in practical terms, and to be certain which flame spread rating you need to use. For cables, you also need to distinguish between flame spread, fire hazard properties and fire resistance. Cables that prevent flame spread Cables running through building levels and walls are a great way for fires to spread. So the most important requirement when establishing fire protection is to use cables with properties that prevent the spread of fire. This is why there are general flame spread classes, and these must always be defined. Our cables have clearly marked flame spread classes that are informative and easy to understand. Halogen free saving lives and money Smoke and gases from burning cables often cause the biggest problems for people and equipment. These problems can be reduced if halogen free cables are used. The smoke from halogen free cables during a fire is much thinner and does not corrode metals. This makes it easier to clear smoke from rooms, potentially saving lives. That is why our cables for alarms and safety systems are halogen free. Still working during a fire The most critical cables must also be fire resistant. This means they must be guaranteed to work even during a fire. This is made possible by special insulation material, which is merely altered rather than destroyed by fire. The cable keeps its shape, the conductors are kept separate and the cable continues to work. These cables are needed for the fire alarm system itself, but also for the safety lighting guiding people out of the building, for the smoke extraction fans and for the lifts. Our range includes fire resistant cables for power supply and for communication. 9
Fire alarms Nexans has a full range of cables for fire alarm systems The right cable for the right use Cables for fire alarms are available with either red or grey sheaths depending on the regulations, aesthetic requirements, etc. In larger addressable systems, twisted pair cable should be used, KLM-LSZH 2x1.0 mm. If shielded cable is required, Nexans supplies the KLMA LSZH. If the cables are required to keep working during a fire, fire resistant Alsecure cables are used. Installation The cables for fire alarms are intended for permanent indoor installation. ELQRB Signal cable for fire alarms. ELQRB construction is as specified in SS 424 16 09. ELQRB 2 x 0,6 mm 18641541 2,9 x 4,2 mm Bobbin/100 ELQRB 2 x 0,6 mm 18641571 2,9 x 4,2 mm Bobbin/500 ELQRB 2 x 1,0 mm 18641641 3,3 x 4,9 mm Bobbin/100 ELQRB 2 x 1,0 mm 18641671 3,3 x 4,9 mm Bobbin/500 ELQRB 4 x 1,0 mm 18641971 5,7 mm Bobbin/500 KLM LSZH Halogen free signal cable. The cable construction is, where applicable, as specified in SFS 2751. KLM LSZH 2x0,8 37156243 4,0 mm Coil/150 KLM LSZH 2x0,8 37156258 4,0 mm Bobbin/600 KLM LSZH 4x0,8 37156443 5,0 mm Coil/150 KLM LSZH 4x0,8 37156458 5,0 mm Bobbin/600 KLM LSZH 2x1,0 Halogen free, pair-twisted signal cable. The cable construction is as specified in SS 424 16 54 (ELQYB). KLM LSZH 2x1,0 37159271 5,7 mm Bobbin/500 KLMA LSZH Halogen free, pair-twisted signal cable. The cable construction is as specified in SS 424 16 54 (ELQYB). KLMA LSZH 2x0,8 37158243 5,0 mm Coil/150 KLMA LSZH 2x0,8 37158258 5,0 mm Bobbin/600 KLMA LSZH 4x0,8 37158443 5,5 mm Coil/150 KLMA LSZH 4x0,8 37158458 5,5 mm Bobbin/600 10
Fire resistant cables maintain circuit integrity even when affected by heat or flames. 11
Performance during a fire Fire resistant cables are recommended for use in installations that must maintain circuit integrity during a fire. Using these cables in important alarm, control, signal and power supply systems means you can guarantee they will not be taken down, even if the fire reaches the cables themselves. No gases, little smoke As well as continuing to work during and after a fire, Nexans fire resistant cables are halogen free so they do not release any toxic or corrosive gases, and only small amounts of smoke, if there is a fire. Studies show that this can save lives and money. Installation Examples of systems that must maintain circuit integrity during a fire include signal and safety systems guiding people out of the building. Other examples are smoke extraction fans and lifts. Fire alarm cables, too, if they pass through areas that are not monitored by detectors, are required to maintain circuit integrity during a fire. ALSECURE PLUS 0,6/1kV, FRHF Fire resistant power cable with round or sector shaped, stranded, soldered copper conductor and concentric shielding. For permanent installation in all areas. Fire performance according to IEC 60331, IEC 60332-3. Alsecure Plus 1kV 2 x 1,5/1,5 27005698 11,9 mm Drum/500 Alsecure Plus 1kV 3 x 1,5/1,5 27004498 12,5 mm Drum/500 Alsecure Plus 1kV 4 x 1,5/1,5 27005798 15,2 mm Drum/500 Alsecure Plus 1kV 2 x 2,5/2,5 27005898 14,7 mm Drum/500 Alsecure Plus 1kV 3 x 2,5/2,5 27005998 15,2 mm Drum/500 Alsecure Plus 1kV 4 x 2,5/2,5 27030198 16,4 mm Drum/500 Alsecure Plus 1kV 4 x 6/6 35123998 18,1 mm Drum/500 Alsecure Plus 1kV 4 x 10/10 35124198 22,0 mm Drum/500 Alsecure Plus 1kV 4 x 16/16 35124398 24,2 mm Drum/500 Alsecure Plus 1kV 4 x 25/16 35124598 26,0 mm Drum/500 Alsecure Plus 1kV 4 x 35/16 35124798 30,0 mm Drum/500 Alsecure Plus 1kV 4 x 50/25 35126598 35,0 mm Drum/500 Alsecure Plus 1kV 4 x 70/35 35125198 36,0 mm Drum/500 Alsecure Plus 1kV 4 x 95/50 35125398 41,0 mm Drum/500 Alsecure Plus 1kV 4 x 120/70 35125598 42,2 mm Drum/500 Alsecure Plus 1kV 4 x 150/70 35125798 49,0 mm Drum/500 Alsecure Plus 1kV 4 x 185/95 35125898 52,0 mm Drum/500 Alsecure Plus 1kV 4 x 240/120 35126198 60,0 mm Drum/500 ALSECURE PLUS TEL, skärmad Fire resistant, twisted pair, shielded telecom and signal cables for permanent installation indoors or in pipes. Fire performance according to IEC60331, IEC 60332-3. Cable Nexans no. Outer diam. Length Alsecure Plus Tel 1 x 2 x 0,9 mm 17541198 6,7 mm Drum/500 Alsecure Plus Tel 2 x 2 x 0,9 mm 17541298 7,4 mm Drum/500 Alsecure Plus Tel 10 x 2 x 0,9 mm 17541698 16 mm Drum/500 Alsecure Plus Tel 2 x 1,5 mm 2 +1,5 mm 2 17544141 8,0 mm Bobbin/100 ALSECURE PREMIUM Fire resistant, twisted pair, fire alarm cables for permanent installation indoors or in pipes. Fire performance according to IEC60331, IEC 60332-3. Cable Nexans no. Outer diam. Length Alsecure Premium 2 x 1,0 mm 17542171 6,2 mm Bobbin/500 Alsecure Premium 10 x 2 x 1,0 mm 17542698 17,0 mm Drum/500 12
ALSECURE PLUS STYR 300/500V Fire resistant, halogen free, unshielded installation cables with round, solid copper conductors. For permanent installation on cable ladders, directly on walls or in pipes or ducting. Fire performance according to IEC60331, IEC 60332-3. Cable Nesans no. Outer diam. Length Alsecure Plus Styr 7G1,5 27001498 14 mm Drum/500 Alsecure Plus Styr 12G1,5 27001198 19,5 mm Drum/500 Alsecure Plus Styr 19G1,5 27004198 22,5 mm Drum/500 Alsecure Plus Styr 7G2,5 27008298 16 mm Drum/500 ALSECURE PREMIUM 300/500V Fire resistant, halogen free control cables with round, solid copper conductors. This cable is designed for permanent installation on cable ladders, directly on walls or in pipes or ducting. Applications include emergency lighting, fire alarm systems and control systems. Fire performance according to IEC60331, IEC 60332-3. Alsecure Premium 3G1,5 27010098 8,0 mm Drum/500 Alsecure Premium 3G2,5 27010198 10,0 mm Drum/500 Alsecure Premium 4G1,5 27010298 9,5 mm Drum/500 Alsecure Premium 5G1,5 27010398 10,0 mm Drum/500 Alsecure Premium 5G2,5 27010598 12,0 mm Drum/500 Another important fire safety property is low smoke development. 13
Access protection Our cables for intruder alarms and entry systems come in a range of types. We have shielded as well as unshielded twisted pair cables up to ten pairs. We also offer flexible single wire cables with four to 12 cores. Combination cables are also available for entry systems cables with twisted pair signal elements and power supply elements (max 100 V). ELQXB (halogen free EKKX) Twisted pair cable for intruder alarms and entry systems. ELQXB 1 x 4 x 0,5 mm 17501041 3,4 mm Bobbin/100 ELQXB 1 x 4 x 0,5 mm 17501071 3,4 mm Bobbin/500 ELQXB 2 x 2 x 0,5 mm 17500241 4,5 mm Bobbin/100 ELQXB 2 x 2 x 0,5 mm 17500271 4,5 mm Bobbin/500 ELQXB 4 x 2 x 0,5 mm 17501141 5,3 mm Bobbin/100 ELQXB 4 x 2 x 0,5 mm 17501171 5,3 mm Bobbin/500 ELQXB 6 x 2 x 0,5 mm 17501241 6,0 mm Bobbin/100 ELQXB 6 x 2 x 0,5 mm 17501271 6,0 mm Bobbin/500 ELQXB 10 x 2 x 0,5 mm 17501341 7,5 mm Bobbin/100 ELQXB 10 x 2 x 0,5 mm 17501371 7,5 mm Bobbin/500 FQQXB Flexible signal and alarm cables for intruder alarms and access control systems. FQQXB 4 x 0,22 mm 2 17523141 3,7 mm Bobbin/100 FQQXB 4 x 0,22 mm 2 17523171 3,7 mm Bobbin/500 FQQXB 6 x 0,22 mm 2 17523241 4,2 mm Bobbin/100 FQQXB 6 x 0,22 mm 2 17523271 4,2 mm Bobbin/500 FQQXB 8 x 0,22 mm 2 17523341 4,7 mm Bobbin/100 FQQXB 8 x 0,22 mm 2 17523371 4,7 mm Bobbin/500 FQQXB 12 x 0,22 mm 2 17523441 5,4 mm Bobbin/100 FQQXB 12 x 0,22 mm 2 17523471 5,4 mm Bobbin/500 FQQXB 4 x 2 x 0,22 mm 2 17524271 5,3 mm Bobbin/500 FQQXB 10 x 2 x 0,22 mm 2 17524898 8,0 mm Drum/500 MHS LSZH Pair-twisted, shielded communication cable with halogen free, flame retardant sheath. The cable construction is, where applicable, as specified in SFS 5739. MHS LSZH 1x4x0,5 38565040 5,0 Coil/100 MHS LSZH 1x4x0,5 38565098 5,0 Drum/1000 MHS LSZH 3x2x0,5 38565145 6,0 Coil/200 MHS LSZH 3x2x0,5 38565198 6,0 Drum/1000 MHS LSZH 5x2x0,5 38565243 6,5 Coil/150 MHS LSZH 5x2x0,5 38565298 6,5 Drum/1000 MHS LSZH 10x2x0,5 38565340 8,5 Coil/100 MHS LSZH 10x2x0,5 38565398 8,5 Drum/1000 14
FLQQBR Combined power supply and signal cables for intruder alarms and entry systems. The twisted pair signal element is unshielded. Cable Nexans no. Outer diam. Length FLQQBR 2 x 1,5 + 2 x 2 x 0,5 mm 2 17513198 8,5 mm Drum/500 FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm 2 17513041 6,5 mm Bobbin/100 FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm 2 17513071 6,5 mm Bobbin/500 FLQQBR 2 x 1,0 + 2 x 2 x 0,22 mm 2 17513271 7,5 mm Bobbin/500 FLAQQBR Combined power supply and signal cables for intruder alarms and entry systems. The twisted pair signal element is unshielded. Cable Nexans no. Outer diam. Length FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm 2 17033341 6,5 mm Bobbin/100 FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm 2 17033371 6,5 mm Bobbin/500 FLAQQBR 2 x 1,0 + 2 x 2 x 0,22 mm 2 17515198 8,0 mm Drum/500 FLAQQBR 3 x 1,0 + 2 x 2 x 0,6 mm 17034298 8,5 mm Drum/500 We have the exact cable that complies to all your needs. 15
Our cables for alarm- and safety systems compared with others. Learn more about what significates our cables for alarm- and safety systems at www.nexans.se Nexans Sweden AB, 514 81 Grimsås, www.nexans.se