Your Inspirations. Our Innovations. UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting Your Data CATALOGUE Revision 0
Table of Contents Table of Contents About Us - Company Profile Online UPS Professional Series (P/P) - Tower Master Series (P/P) - Tower Master Series (P/P) - Combo Master Series (P/P) - -in- Rack/ Tower Master Series (P/P) - Tower Master Series (P/P) - Rack Mount Master Series (P/P) - Tower Power Series (P/P) 0 Line Interactive UPS PRO Series Inverter UPS IPS Series Solar UPS PDC Series - DC UPS PCC Series PSI Hybrid Series PSI On-Grid Series PSI Off-Grid Series PSS Series 5 Software & Accessories Appendixz
About Us - Company Profile Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products manufactured under the brand name PROLiNK since 99. With more than two decades of professional experience in the information communications sector, PROLiNK is now renowned as a specialist in its field, especially in area of Backup UPS products. Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its current network of sales offices in more than 0 countries, customers can be assured that PROLiNK is able to provide the right solutions to meet the needs of both home and business users within each geographical location both efficiently and effectively. The company s quest for continuous improvement and quality assurance to its customers has earned us the ISO900 quality certification since 999. With its consistently strong commitment to quality, customers can be assured of they are getting true value - superior quality products at affordable prices. Our Mission Accentuate The Best For The E-generation PROLiNK aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is becoming more and more commonplace. PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our products are crafted to enhance performance whether you are at work or play our products work harder, while you work smarter to achieve your desired results with less effort and better efficiency. Providing value to our consumers whether home or business users, remains a firm commitment of PROLiNK. With its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable solutions for their technological needs, while business users are assured of reliable and secure solutions for their network infrastructure. Our Vision Ideas, Innovation and Information PROLiNK aims to be the key driving force behind technological changes and improvements in both developing and developed countries. With its strong focus on technology, our team sets high standards for itself in the areas of innovation, change and improvement so as to provide the next generation of users with products that are suitable for their technology advanced environments. The small i in PROLiNK represents ideas, innovation and information three key pillars of growth that drive us towards achieving excellence in our field of expertise and challenges us to think beyond our usual boundaries.
About Us - Company Profile Core Values Secured Information Management With more than two decades of professional experience in providing backup power solutions to our customers, we are able to support our customers with superior technological know-how and expertise, as well as advice on market trends. At the same time, we are also fully committed to protecting the privacy of our customers and to manage confidential information discreetly. Innovative Design Our products are carefully thought out to ensure that each item is designed to meet the needs of our customers. With the team s solid experience in the UPS market, customers can be certain that our designs are innovative yet functional, and suitable for each dynamic market that we have a presence in. Superior Service Standards Strict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item meets our strict standards from the individual components to the actual finished product. Total Quality Assurance System Our products go through careful planning and checks at every stage of the production cycle - from the beginning stages of product design to the manufacturing and finally the actual delivery of the goods. This guarantees that our customers receive only the best quality goods of high reliability and durability. Our total quality system has been audited and approved by globally recognized bodies. Range of UPS The wide range of our products gives you an infinite range of solutions:. Online UPS. Line Interactive UPS. Inverter UPS. Solar UPS
Online UPS Professional Series (P/P) - Tower Online Professional Series KVA KVA The Professional Series (P/P) - Tower is an advanced, affordable on-line double-conversion technology single-phase UPS system. Professional Series is available with 000VA to 000VA models and these offer high reliability for workstations, server and network equipment. The Professional Series is designed to protect against power outages, disturbances and spikes. It also provides high-efficient charger with PFC. High battery charging current and battery extension assembly is available for the long run time application. In order to supply pure and clean power to sensitive devices, an optional of isolation transformer can be attached to UPS unit without taking extra space. PRO90S/ L PRO90S/ L PRO90S/ L PRO90S/ L True Double-Conversion Online UPS Wide input voltage range (0~00VAC) Input Power Factor correction 0.9 Output Power Factor 0.0 Generator compatible LCD User Interface RS- communication port or mini slot for USB / RS- / AS00 / SNMP communication Smart battery charger design for optimized battery performance Optional isolation transformer available Small Computer Network Local Area Network (LAN) Work-Stations Service Rear Panel 5 9 PRO90S/ PRO90S 5 9 PRO90L/ PRO90L 9 5 PRO90S/ PRO90S 9 PRO90L/ PRO90L 5 For KVA to KVA model. Output receptacles. AC input. Input circuit breaker. Network/Fax Modem Surge Protection 5. RS- communication port / SNMP intelligent slot. External battery connection (only available for L model). Output terminal. Output circuit breaker 9. Fan
Online UPS Options RS- Port for communication. AS-00 Card for external alarm signal. SNMP Card for data communication via network connection. Output Isolation Transformer. External PDU & Maintenance Bypass Switch. (suitable for UPS up to KVA only) Full Specifications MODELS PRO90S/ L PRO90S/ L PRO90S/ L PRO90S/ L 000 VA/ 00 W 000 VA/ 00 W 000 VA/ 00 W 000 VA/ 00 W INPUT Nominal Voltage 0/ 0/ 0/ 0VAC Voltage Range Nominal Frequency Frequency Range Power Factor 0Vac < Vin < 90Vac @ 50% LOAD/ Vac < Vin < 00Vac @ 00% LOAD 50 or 0Hz 0 ~ 0Hz 0.9 OUTPUT Output Voltage 00/ 0/ 0/ 0/ 0VAC Static Regulation ±% ±% Frequency Frequency Range 50Hz or 0Hz auto selection ~ 5 Hz or 5 ~ Hz Power Factor Current Crest Ratio Voltage Distortion 0. : Liner Load % THD % THD Non-Liner Load % THD % THD Waveform Pure Sinewave EFFICIENCY AC Mode Up to % BATTERY Type Valve regulated Lead Acid battery (Maintenance free batteries) Standard Model 9AH 0AH Recharge Time (Typical) hours recover to 90% capacity Charging Current.0 A (max) Type Depending on the application Long-Run Model OVERLOAD 00% < Load < 0% Charging Current Depending on the application.0 A or.0 A (max) Overload warning only (No shutdown) 00% < Load < 0% 0 sec >0%.5 sec INDICATORS LCD Display Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W H 9 x 5 x 0 90 90 Net Weight (kgs) 9.. 5. Dimension (mm) D W H 9 5 0 90 90 Net Weight (kgs)..9.5. ENVIRONMENT Operation Humidity Ambient Temperature Noise Level <90% non-condensing 0 C - +0 C 5dBA @ Meter Regulations Safety: EN00--; EMI00-; EN00- MANAGEMENT USB Support Windows 000/ 00/ XP/ Vista/ 00/, Linux, Unix and MAC L means Long-run model; S means Standard model; I means Isolation Transformer available (optional). Specification for Online UPS with Isolation Transformer to be provided upon request. Symbols: / meant for OR; meant for Multiply of. All specifications, designs and contents are subjected to changes without prior notice. 5
Online UPS Master Series (P/P) - Tower Online Master Series KVA 0KVA Master Series (P/P) - Tower is a true on-line double-conversion technology single-phase UPS system which provides clean, high level quality power for critical devices such as small computer centers, servers, telecom applications and industrial applications. It is available from KVA to 0KVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes. Master Series (P/P) - Tower is designed with a smart battery charger to optimize battery performance. High battery charging current and battery extension assembly is available for long run applications. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available for the KVA and 0KVA models. An optional of isolation transformer can be attached to UPS unit without taking extra space. True Double-Conversion Online UPS Wide input voltage range (0~00VAC) Input Power Factor correction 0.99 Output Power Factor 0.0 Generator compatible LCD User Interface RS- communication port or mini slot for USB/ RS-/ AS00/ SNMP communication Smart battery charger design for optimized battery performance Optional isolation transformer available PRO0S/ L PRO05S/ L PRO0S/ L PRO0S/ L PRO0S/ L PRO0S/ L Small Computer Network Local Area Network (LAN) Work-Stations Service Rear Panel 9 5 PRO0S/ PRO05S 5 9 PRO0L/ PRO05L 0 9 5 PRO0S/ PRO0S 9 5 0 PRO0L/ PRO0L For KVA to KVA model. Programmable outlets: connect to noncritical loads. Output receptacles: connect to missioncritical loads. AC input. Input circuit breaker 5. Network/Fax/Modem surge protection. Emergency power off function connector (EPO). USB communication port. RS- communication port 9. SNMP intelligent slot 0. External battery connection (only available for L model). Output terminal. Output circuit breaker. Fan
Online UPS 9 5 5 5 PRO0S/ PRO0S 0 9 5 5 5 PRO0L/ PRO0L 0 For KVA to 0KVA model. RS- communication port. USB communication port. Emergency power off function connector (EPO connector). Share current port (only available for parallel model) 5. Parallel port (only available for parallel model). Intelligent slot. Charger fan. Power stage fan 9. Maintenance bypass switch 0. Input circuit breaker. Input/Output terminal. Output terminal. Output terminal. External battery terminal (only available for Long-run model) 5. Utility input terminal. Output IEC Socket Battery Pack For KVA to KVA model KVA/.5KVA KVA/ KVA Battery Type VAH V9AH VAH V9AH VAH V9AH Battery Number pcs pcs pcs pcs pcs pcs Dimension (DxWxH) 9 5 0 90 55 90 Weight (kg) 0 0 55 For KVA to 0KVA model Battery Type KVA/ 0KVA VAH V9AH VAH V9AH VAH V9AH Battery Number 0 pcs 0 pcs 0 pcs 0 pcs 0 pcs 0 pcs Dimension (DxWxH) 59 50 5 59 50 5 0 50 5 Weight (kg) 09 5 90
Online UPS Options AS-00 Card for external alarm signal. SNMP Card for data communication via network connection. Output Isolation Transformer. External PDU & Maintenance Bypass Switch. (suitable for UPS up to KVA only) Full Specifications MODELS PRO0S/ L PRO05S/ L PRO0S/ L PRO0S/ L PRO0S/ L PRO0S/ L 000 VA/ 00 W 500 VA/ 00 W 000 VA/ 00 W 000 VA/ 00 W 000 VA/ 00 W 0000 VA/ 000 W INPUT Nominal Voltage 0/ 0/ 0/ 0VAC Voltage Range Nominal Frequency Frequency Range Power Factor 0Vac <Vin<90Vac @ 50% LOAD / 5Vac <Vin<00Vac @ 00% LOAD 50 or 0Hz 0 ~ 0Hz 0.99 OUTPUT Output Voltage 00/ 0/ 0/ 0/ 0VAC Static Regulation ±% Frequency 50Hz or 0Hz auto selection or selectable Frequency Range ~ 5Hz or 5 ~ Hz Power Factor 0. Current Crest Ratio : Voltage Distortion Linear Load % THD % THD % THD Non-Linear Load % THD % THD % THD Waveform Pure Sinewave EFFICIENCY AC Mode Up to 9% BATTERY Type Valve regulated Lead Acid battery (Maintenance free batteries) Standard Model AH 9AH AH 9AH AH 9AH Recharge Time (Typical) hours recover to 90% capacity 9 hours recover to 90% capacity Charging Current.0 A (max) Type Depending on the application Long-Run Model Depending on the application Charging Current.0 A (max).0 A (max) OVERLOAD 00% < Load < 0% Overload warning only (No shutdown) 00% < Load < 0% 0 sec >0%.0 sec INDICATORS LCD Display Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL Standard Model Dimension (mm) D x W H 9 x 5 x 0 90 59 x 50 x 5 Net Weight (kgs) Long-Run Model Dimension (mm) D W H 9 5 0 90 59 x 50 x 5 Net Weight (kgs) 5 ENVIRONMENT Operation Humidity <90% non-condensing Ambient Temperature 0 C - +0 C Noise Level 5dBA @ Meter 55dBA @ Meter 5dBA @ Meter Regulations Safety: EN00--; EMI: EN00-; EN00- MANAGEMENT USB/ RS- Support Windows 000/ 00/ XP/ Vista/ 00/, Linux, Unix and MAC Derate to 0% of capacity in Frequency converter mode and to 0% when the output valtage is adjusted to 0VAC. If the UPS is installed or used in a place where the altitude is above than 000m, the output power must be derated one percent per 00m. L means Long-run model; S means Standard model; I means Isolation Transformer available (optional). Specification for Online UPS with Isolation Transformer to be provided upon request. Symbols: / meant for OR; meant for Multiply of. All specifications, designs and contents are subjected to changes without prior notice.
Online UPS True double-conversion Online UPS A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications. Output Power Factor 0. Compared to the online UPSs in the current market, Master Series (P/P) provides better output power factor up to 0.. It offers higher performance and efficiency for critical applications. Wide Input Voltage Range (0 V -00 V) Master Series (P/P) can still provide stable power to connected devices under unstable power environments. Programmable Power Management Outlets With programmable power management outlets, users can easily and indepenntly control load segments. During power failure, this feature enables users to extend battery time to missioncritical devices by shutting down the non-critical devices. Programmable Outlets (P) - connect to non-critical devices 50/0 Hz Frequency Converter Mode Lock output frequency at 50Hz or 0Hz to suit power sensitive equipments. ECO Mode Operation For Energy Saving Offers efficiency as high as 9% to cut energy usage & cost. UPS power application via static bypass, timely returning to online double conversion when the need arises. Emergency Power Off (EPO) Function This feature can secure the personnel and equipment in case of fires or other emergencies. SNMP + USB + RS- Multiple Communications For -KVA Models This feature allows either USB or RS- communication port to work with SNMP interface simultaneously. Higher Accuracy For Output Voltage With advanced control firmware, Master Series (P/P) provides high accuracy within +/- % for output voltage. It can be applied to precious test & IT equipment. Smart Battery Charger Design To Optimize Battery Performance Master Series (P/P) -KVA is equipped with -stage charger design to guarantee battery discharge time. Besides, it will adjust charging voltage according to outside temperature. This features will extend the useful service life of batteries. Master Series (P/P) KVA and above models are equipped with -stage extendable charger for optimized battery performance. This feature extends the useful service life of batteries and optimizes battery recharge time. Besides, the extendable charger design can be stacked in numbers for large-capacity battery charging. DSP Technology Applied For KVA And Above Models A DSP controller provides an improved and cost-effective solution with high performance. Maintenance Bypass Available For KVA And Above Models Internal bypass assures continuous power to critical devices during UPS maintenance. Optional Hot Standby Mode And N+X Parallel Redundancy Available For KVA And Above Models For genuinely redundant power protection, Master Series (P/P) (KVA and above models) can either be used in parallel operation with up to units or hot standby mode. Slave UPS will back up the load in the event of critical component failure. It increases power safety and availability. Adjustable Battery Numbers For KVA And Above Models Master Series (P/P) (KVA and above models) can still normal operate well with only or 9 internal batteries. Built-in Isolation Transformer (Option) With built-in isolation transformer, the UPS will offer full isolation and complete common mode noise rejection for connected precious equipment. It become an ideal power source with 00% protection against unexpected AC power problems. 9
Online UPS Master Series (P/P) - Combo Online Master Series KVA 0KVA Master Series (P/P) - Combo is designed with a very small footprint size to solve the problem of limited space with the support of kva and 0kVA UPS system. Master Series (P/P) Combo used true on-line double-conversion technology single-phase UPS system which provides clean, high level quality power for critical devices such as small computer centres, servers & telecom applications. Master Series (P/P) - Combo is available from KVA and 0KVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes. Smart battery charger design to optimize battery performance and high battery charging current and battery extension assembly is available for long run applications. PRO0CL/ PRO0CL PRO0C/ PRO0C True double-conversion on line UPS DSP technology guarantees high performance Wide input voltage range (0-00 VAC) Active input power factor correction 0.99 Output power factor 0. 50Hz/0Hz frequency converter mode Standard backup UPS and long backup UPS in one integrated unit Adjustable battery number from blocks to 0 blocks Adjustable charging current can be changed via LCD or software (A~A) Emergency power off function (EPO) USB and RS- communications port and mini slot for AS00/ SNMP communication. Maintenance bypass available Small Computer Network Local Area Network (LAN) Work-Stations Service Rear Panel 9 5 5 5 5 0 For KVA to 0KVA model. RS- communication port. USB communication port. Emergency power off function connector (EPO connector). Intelligent slot 5. Power stage fan. Maintenance bypass switch. Input circuit breaker. Input/Output terminal 9. External battery terminal (only available for Long-run model) 0. Battery Compartment (only available for Standard model) PRO0CL/ PRO0CL PRO0C/ PRO0C 0
Online UPS Options AS-00 Card for external alarm signal. SNMP Card for data communication via network connection. Output Isolation Transformer. Full Specifications MODELS PRO0C/ CL PRO0C/ CL 000 VA/ 00 W 0000 VA/ 000 W INPUT Nominal Voltage 0/ 0/ 0/ 0VAC Voltage Range Nominal Frequency Frequency Range Power Factor 0Vac <Vin<90Vac @ 50% LOAD / Vac <Vin<00Vac @ 00% LOAD 50 or 0Hz ~ Hz 0.99 OUTPUT Output Voltage 00/ 0/ 0/ 0/ 0VAC Static Regulation Frequency Frequency Range ±% 50Hz or 0Hz auto selection or selectable ~ 5Hz or 5 ~ Hz Power Factor Current Crest Ratio 0. : Voltage Distortion Linear Load % THD Non-Linear Load 5% THD Waveform Pure Sinewave EFFICIENCY AC Mode Up to 90% BATTERY Type Valve regulated Lead Acid battery (Maintenance free batteries) Standard Model 9AH Recharge Time (Typical) 9 hours recover to 90% capacity Charging Current.0 A (max) Type Depending on the application Long-Run Model OVERLOAD 00% < Load < 0% Charging Current Depending on the application.0 A (max) 0 mins 00% < Load < 0% min >0%.0 sec INDICATORS LCD Display Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W H Dimension (mm) D W H 0 x 9 x 0 x 9 x 0 x 9 x 0 x 9 x Net Weight (kgs) Net Weight (kgs) 0 5 ENVIRONMENT Operation Humidity Ambient Temperature <95% non-condensing 0 C - +0 C Noise Level 55dBA @ Meter 5dBA @ Meter Regulations Safety: EN00--; EMI: EN00-; EN00- MANAGEMENT USB/ RS- Support Windows 000/ 00/ XP/ Vista/ 00/, Linux, Unix and MAC L means Long-run model; S means Standard model; I means Isolation Transformer available (optional). Specification for Online UPS with Isolation Transformer to be provided upon request. Symbols: / meant for OR; meant for Multiply of. All specifications, designs and contents are subjected to changes without prior notice.
Online UPS Master Series (P/P) - -in- Rack/ Tower Online Master Series KVA 0KVA Master Series (P/P) -in- Rack/Tower is a true on-line double-conversion technology single-phase UPS system with U universal-mount case. It can be easily installed as a floor-standing tower or with a 9-inch rackmount bracket. The Master Series was designed with a high density output power factor of 0.9 to provide higher performance and efficiency to critical applications such as sensitive networks, small computer centers, servers and telecom applications. It is available in capacities from KVA to 0KVA with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes. Master Series (P/P) - -in- Rack/Tower has been designed with a hot-swappable battery to ensure clean and uninterruptible power to protected equipment during battery replacement. A high battery charging current and battery extension assembly is available for long run applications. Parallel redundancy which will back up the load in the event of critical component failure is available for the kva and 0kVA models. Front panel digital display can be easily adjusted through LCD setting to suit the installation format, whether it is left vertically standing or flat wall mounted. PRO0RS to PRO0RS/ PRO0RL to PRO0RL True Double-Conversion Online UPS Rack or Tower design Wide input voltage range (0~00VAC) Input Power Factor correction 0.99 Output Power Factor 0.90 50/0Hz frequency converter mode Hot-Swappable battery design Emergency Power Off (EPO) function ECO Mode Operation for energy saving General Compatible Charger capacity expansion to A for long-run models SNMP+USB+RS multiple communications Smart battery charger design for optimized battery performance Selectable output voltage via LCD panel PRO0RS/ PRO0RS/ PRO0RL/ PRO0RL Small Computer Network Local Area Network (LAN) Work-Stations Service 9 Rack Mount Rear Panel 5 0 9 PRO0RS/PRO05RS/PRO0RS 5 0 9 PRO0RL/PRO05RL/PRO0RL 5 0 PRO0RS 5 0 PRO0RL 9 9 For KVA to KVA model. Programmable outlets:connect to non-critical loads. Output receptacles: Connect to mission-critical loads. AC input. Input circuit breaker 5. Network/Fax/Modem surge protection. Emergency power off function connector (EPO). USB communication port. RS- communication port 9. SNMP intelligent slot 0. Battery Compartment (only available for Standard model). Input terminal. Fan
Online UPS 9 0 PRO0RS/RL PRO0RS/RL 5 For KVA to 0KVA model. Programmable outlets:connect to non-critical loads. Output receptacles: Connect to mission-critical loads. AC input. Input circuit breaker 5. Network/Fax/Modem surge protection. Emergency power off function connector (EPO). USB communication port. RS- communication port 9. SNMP intelligent slot 0. Battery Compartment (only available for Standard model). Input terminal. Fan. Parallel port (only available for parallel model). External maintenance by-pass switch connection 5. Output Terminal. Ground Battery Pack For KVA to 0KVA model KVA.5KVA KVA KVA KVA 0KVA Battery Type V9AH VAH V9AH Battery Number pcs pcs pcs pcs 0 pcs Dimension (DxWxH) 0 00 50 Weight (kg). 9... 5 Options AS-00 Card for external alarm signal. SNMP Card for data communication via network connection MODBUS Card for communication Universal Rackmount Slider for installation in rack cabinets External PDU & Maintenance Bypass Switch (suitable for UPS up to KVA only) Maintenance Bypass Switch [MBS] (for UPS to 0KVA only) External Automatic Transfer Switch (ATS) MBS-rack-UK Schuko IEC NEMA ATS-R MBS - to 0K
Online UPS Full Specifications MODELS INPUT Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor OUTPUT Output Voltage Static Regulation Frequency Frequency Range Power Factor Current Crest Ratio Voltage Distortion Waveform EFFICIENCY AC Mode BATTERY Standard Model Long-Run Model OVERLOAD >0% INDICATORS PHYSICAL PRO0RS/ RL PRO05RS/ RL PRO0RS/ RL Apparent Power 000 VA 500 VA 000 VA Active Power (Standard Model) Active Power (Long-Run Model) Type Recharge Time (Typical) Charging Current Type Charging Current 0/ 0/ 0/ 0VAC 0Vac <Vin<90Vac @ 50% LOAD / 0Vac <Vin<00Vac @ 00% LOAD 50 or 0Hz 0 ~ 0Hz 0.99 PRO0RS/ RL 000 VA PRO0RS/ RL 000 VA Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PRO0RS/ RL 0000 VA 900 VA 50 VA 00 VA 00 VA 500 VA 9000 VA 00 VA 00 VA 00 VA 00 VA 00 VA 000 VA 00% < Load < 0% Overload warning only (No shutdown) 0 mins 00% < Load < 0% 0 sec min LCD Display Standard Model 00/ 0/ 0/ 0/ 0VAC ±% 50Hz or 0Hz auto selection or selectable ~ 5Hz or 5 ~ Hz 0.9 @ Standard Model, 0. @ Long-Run Model 5: : 5: : Linear Load % THD Non-Linear Load % THD % THD % THD Pure Sinewave Dimension (mm) D x W H Up to 90% Valve regulated Lead Acid battery (Maintenance free batteries) 9AH AH 9AH hours recover to 90% capacity 9 hours recover to 90% capacity.0 A (max) Depending on the application Depending on the application.0 A or.0 A (max).0 A (max).0 A (max) 0xx (U).0 sec sec 0xx (U) 00xx (U) UPS Unit: 50xx (U) Battery Unit: 50xx (U) UPS Unit: xx (U) Battery Unit: 50xx (U) Net Weight (kgs) Dimension (mm) D W H Long-Run Model Net Weight (kgs) ENVIRONMENT Operation Humidity Ambient Temperature Noise Level Regulations MANAGEMENT USB/ RS-.9. 0xx (U) 0xx (U). 0.. 0. 00xx(U). <90% non-condensing 0 C - +0 C 50dBA @ Meter Safety: EN00--; EMI: EN00-; EN00- UPS Unit: Battery Pack: 5 50xx (U) Support Windows 000/ 00/ XP/ Vista/ 00/, Linux, Unix and MAC UPS Unit: 0 Battery Pack: xx (U) 0 L means Long-run model; S means Standard model. Symbols: / meant for OR; meant for Multiply of. All specifications, designs and contents are subjected to changes without prior notice.
Online UPS True Double-conversion Online UPS A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications. User-friendly And Easy-shift LCD Display The front panel digital display can be easily shifted through LCD setting to suit the installation format, vertically stand or flat wall mount. Output power factor 0.9 Master (P/P) - -in- Rack/Tower Series is a highdensity UPS with output power factor 0.9 to provide higher performance and efficiency to critical applications. Programmable Power Management Outlets With programmable power management outlets, users can easily and independently control load segments. During power failure, this feature enables users to extend battery time to mission critical devices by shutting down the non-critical devices. Programmable Outlets (P) - connect to non-critical devices Rack Display Tower Display Rack/ Tower Design Master (P/P) - -in- Rack/Tower Series is designed in true U universal-mount case. It can be easily installed as floor-standing tower or in 9-inch rackmount bracket. ECO And Advanced ECO Mode For Energy Saving It allows UPS to operate in high efficiency up to 9%in energy saving ECO mode and even up to 9%. In this operation mode, load is supplied by the mains. In the event of a mains failure, the inverter takes over the load and provides supply continuity to the connected systems. Emergency Power Off Function (EPO) This feature can secure the personnel and equipment in case of fires or other emergencies. 9 Rack-mounting Floor-standing Tower Higher Output Crest Radio Perfect For Generator And Compressor Compared to general online UPS, Master (P/P) - -in- Rack/Tower Series provide higher current crest ratio as 5:. It can support not only precious IT equipment, but also compressors and motor-type devices. Output Voltage Regulation < % Master (P/P) - -in- Rack/ Tower Series offers better output voltage regulation (+/-%), which ensures higher compatibility with even the most sensitive power supplies. Hot-swappable Battery Design This design ensures clean and uninterruptible power to protected equipment during battery replacement. Long-run Models Available To provide longer backup time, we also offer long-run models. If additional runtime is required, matching external battery units is available. 5
Online UPS Master Series (P/P) - Tower Online Master Series 0KVA 0KVA Master Series (P/P) - Tower is a true on-line double-conversion technology three-phase input / single-phase output UPS system which ensure maximum protection and power quality for any type of load, especially for mission critical applications such as data center systems, security systems, industrial processes and telecommunications. It is available from 0KVA to 0KVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes. Master Series (P/P) - Tower with built in phase auto adapt function simplifies wire installation and single phase input is acceptable. With IGBT technology, it provides generator compatible where handles frequency variations and other power fluctuations that occur during generator operation. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available. An optional of isolation transformer can be attached to UPS unit without taking extra space. PRO0S/L PRO5L/ PRO0L PRO5S/ PRO0S True Double-Conversion Online UPS DSP technology guarantees high performance Output Power Factor 0.0 Input Power Factor Correction 0.99 Wide input voltage range Active power factor correction in all phases 50/0Hz frequency converter mode Emergency Power Off (EPO) function SNMP+USB+RS multiple communications Adjustable battery numbers Maintenance bypass available Optional N+X parallel redundancy Optional isolation transformer available Local Area Network (LAN) Telecommunication Devices Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) Rear Panel 5 5 9 0 PRO0S 5 5 9 0 PRO0L For 0KVA model. RS- communication port. USB communication port. Emergency power off function connector (EPO connector). Share current port (only available for parallel model) 5. Parallel port (only available for parallel model). Intelligent slot. Charger fan. Power stage fan 9. Maintenance by-pass switch 0. Input circuit breaker. Output circuit breaker for receptacles. Output receptacles: connect to mission-critical loads. Input/Output terminal. External battery connector (only available for 0KL)
Online UPS 9 5 5 0 PRO5L PRO0L 9 9 0 5 5 0 PRO5S PRO0S For 5KVA to 0KVA model. RS- communication port. USB communication port. Emergency power off function connector (EPO connector). Share current port (only available for parallel model) 5. Parallel port (only available for parallel model). Intelligent slot. Charger fan. Power stage fan 9. Maintenance by-pass switch 0. Input circuit breaker. Output circuit breaker for receptacles. Output receptacles: connect to mission-critical loads. Input/Output terminal. External battery connector (only available for 0KL) 5. Output terminal. Output terminal. External battery terminal (only available for Long-run model). Utility input terminal 9. Non-isolated Neutral terminal (only available for parallel system) 0. Grounding terminal (only available for parallel system) For 0K model For 5K & 0K model 9 0 9 5 5 Options AS-00 Card for external alarm signal. SNMP Card for data communication via network connection MODBUS Card for communication Output Isolation Transformer
Online UPS Full Specifications MODELS PRO0S/ L PRO5S/ L PRO0S/ L 0 KVA/ KW 5 KVA/ KW 0 KVA/ KW INPUT Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor OUTPUT Output Voltage Static Regulation Frequency Frequency Range Power Factor Current Crest Ratio Voltage Distortion Waveform EFFICIENCY AC Mode BATTERY Standard Model Long-Run Model OVERLOAD 00% < Load < 0% 0/ 0/ 00/ 5VAC 00Vac < Vin < 0Vac 50 or 0Hz 5 ~ Hz 0.99 00/ 0/ 0/ 0/ 0VAC ±% 50Hz or 0Hz auto selection or selectable ~ 5 Hz or 5 ~ Hz 0. : Liner Load % THD Non-Liner Load % THD 5% THD % THD Pure Sinewave Up to 9% Type Valve regulated Lead Acid battery (Maintenance free batteries) 9AH Recharge Time (Typical) 9 hours recover to 90% capacity Charging Current.0 A (max).0 A (max) Type Depending on the application Depending on the application Charging Current.0 A (max).0 A (max) 0 mins 00% < Load < 0% min >0% sec INDICATORS LCD Display Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL Standard Model Dimension (mm) D x W H 59 x 50 x 5 5 50 Net Weight (kgs) Long-Run Model Dimension (mm) D W H 59 50 5 59 50 Net Weight (kgs) ENVIRONMENT Protection IP0 Operation Humidity <95% non-condensing Ambient Temperature 0 C - +0 C Noise Level 5dBA @ Meter 0dBA @ Meter Regulations Safety: EN00--; EMI00-; EN00- MANAGEMENT USB Support Windows 000/ 00/ XP/ Vista/ 00/, Linux, Unix and MAC L means Long-run model; S means Standard model; I means Isolation Transformer available (optional). Specification for Online UPS with Isolation Transformer to be provided upon request. Symbols: / meant for OR; meant for Multiply of. All specifications, designs and contents are subjected to changes without prior notice.
Online UPS Master Series (P/P) - Rack Mount Online Master Series 0kVA 0kVA Master Series (P/P) - Rack mount is a true on-line double-conversion technology three-phase input / single-phase outputups system with U to U universal-mount case. It is designed to ensure maximum protection and power quality for any type of load, especially for mission critical applications such as data center systems, security systems and telecommunications. It is available from 0kVA and 0kVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes. Master Series (P/P) - Rack mount with IGBT technology, it provides generator compatible where handles frequency variations and other power fluctuations that occur during generator operation. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available. PRO0RS/ RL True double-conversion DSP technology guarantees high performance Output Power Factor 0. Wide input voltage range Active power factor correction in all phases 50Hz/0Hz frequency converter mode Eco mode operation for energy saving (ECO) Emergency power off function (EPO) Generator compatible SNMP+USB+RS- multiple communications Adjustable battery numbers Optional N+X parallel redundancy PRO0RS/ RL Local Area Network (LAN) Telecommunication Devices Data Centre 9 Rack Mount Storage PLCS Emergency Alarm Devices Rear Panel 5 9 0 PRO0RS/ RL 5 9 0 For 0kVA to 0kVA model. RS- communication port. USB communication port. Emergency power off function connector (EPO connector). Parallel port (only available for parallel model) 5. Intelligent slot. Fan. External maintenance by-pass switch connection. Input circuit breaker 9. Input/Output terminal 0. Output terminal. Battery terminal. Input terminal PRO0RS/ RL 9
Online UPS Options AS-00 Card for external alarm signal. SNMP Card for data communication via network connection MODBUS Card for communication Universal Rackmount Slider for installation in rack cabinets External Maintenance Bypass Switch (0kVA only) Full Specifications MODELS PRO0RS/ RL PRO0RS/ RL 0kVA/ kw 0kVA/ kw INPUT Nominal Voltage 0/ 0 /00/ 5VAC Voltage Range Nominal Frequency Frequency Range Power Factor 00Vac <Vin <0Vac 50 or 0Hz ~ Hz 0.99 OUTPUT Output Voltage Static Regulation Frequency Frequency Range Power Factor Current Crest Ratio Voltage Distortion Waveform EFFICIENCY AC Mode BATTERY Standard Model Long-Run Model OVERLOAD >0% INDICATORS PHYSICAL Type Recharge Time (Typical) Charging Current Type Charging Current Valve regulated Lead Acid battery (Maintenance free batteries) 9AH 9 hours recover to 90% capacity.0 A (max).0a (max) Depending on the application Depending on the application.0 A (max) 00% < Load < 0% 0 mins 00% < Load < 0% min LCD Display Standard Model Linear Load Non-Linear Load Dimension (mm) D x W H 00/ 0/ 0/ 0/ 0VAC ±% 50Hz or 0Hz auto selection or selectable ~ 5Hz or 5 ~ Hz 0. : % THD 5% THD Pure Sinewave Up to 9%.0 sec Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions UPS Unit: x x (U) Battery Pack: 50 x x (U) UPS Unit: x x (U) BatteryPack: 50 x x (U) x Net Weight (kgs) Dimension (mm) D W H Long-Run Model Net Weight (kgs) ENVIRONMENT Protection Operation Humidity Ambient Temperature Noise Level Regulations MANAGEMENT USB/ RS- UPS Unit: Battery Pack: x x (U) UPS Unit: Battery Pack: x x x (U) IP0 <95% non-condensing 0 C - +0 C 5dBA @ Meter 0dBA @ Meter Safety: EN00--; EMI: EN00-; EN00- Support Windows 000/ 00/ XP/ Vista/ 00/, Linux, Unix and MAC L means Long-run model; S means Standard model. Symbols: / meant for OR; meant for Multiply of. All specifications, designs and contents are subjected to changes without prior notice. 0
Online UPS Master Series (P/P) - Tower Online Master Series 0kVA 0kVA Master Series (P/P) - Tower is a true on-line double-conversion technology three-phase input/ three-phase output UPS system, it is an ideal for protection and power quality for small server room, medical devices, industrial processes and telecommunications facilities. It is available from 0kVA to 0kVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes. Master Series (P/P) - Tower with IGBT technology, it provides generator compatible where handles frequency variations and other power fluctuations that occur during generator operation. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available. An optional of isolation transformer can be attached to UPS unit without taking extra space. PRO0S/L PRO0S/L True double-conversion DSP technology guarantees high performance Wide input voltage range Active power factor correction in all phases 50Hz/0Hz frequency converter mode Eco mode operation for energy saving (ECO) Accepts dual power inputs Emergency power off function (EPO) Generator compatible SNMP+USB+RS- multiple communications Maintenance bypass available Optional N+X parallel redundancy Optional isolation transformer offers full isolation and complete common mode noise Local Area Network (LAN) Telecommunication Devices Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) Rear Panel 9 5 0 5 PRO0S/L PRO0S/L For 0kVA to 0kVA model. RS- communication port. USB communication port. Emergency power off function connector (EPO connector). Share current port (only available for parallel model) 5. Parallel port (only available for parallel model). Intelligent slot. Charger fan. Power stage fan 9. Maintenance bypass switch 0. Bypass Input Circuit Breaker (Only available for dual input unit). Input circuit breaker. Input/Output terminal. Output terminal. External battery terminal (only available for Long-run model) 5. Bypass input terminal (Only available for dual input). Input terminal
Online UPS Options AS-00 Card for external alarm signal. SNMP Card for data communication via network connection MODBUS Card for communication Output Isolation Transformer Full Specifications MODELS PRO0S/ L PRO0S/ L 0kVA/ kw 0kVA/ kw INPUT Nominal Voltage 0/ 0 /00/ 5VAC Voltage Range Nominal Frequency Frequency Range Power Factor 00Vac <Vin <0Vac 50 or 0Hz ~ Hz 0.99 OUTPUT Output Voltage 0/ 0/ 00/ 5VAC Static Regulation Frequency Frequency Range ±% 50Hz or 0Hz auto selection or selectable ~ 5Hz or 5 ~ Hz Power Factor Current Crest Ratio 0. : Voltage Distortion Linear Load % THD Non-Linear Load 5% THD Waveform Pure Sinewave EFFICIENCY AC Mode Up to 9% BATTERY Type Valve regulated Lead Acid battery (Maintenance free batteries) Standard Model 9AH Recharge Time (Typical) 9 hours recover to 90% capacity Charging Current.0 A (max).0 A (max) Type Depending on the application Long-Run Model OVERLOAD 00% < Load < 0% Charging Current Depending on the application.0 A (max) 0 mins 00% < Load < 0% min >0% sec INDICATORS LCD Display Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL Standard Model Long-Run Model Dimension (mm) D x W H 5 x 50 x Net Weight (kgs) 09 Dimension (mm) D W H 59 x 50 x Net Weight (kgs) 0 ENVIRONMENT Protection IP0 Operation Humidity Ambient Temperature <95% non-condensing 0 C - +0 C Noise Level 5dBA @ Meter 0dBA @ Meter Regulations Safety: EN00--; EMI: EN00-; EN00- MANAGEMENT USB/ RS- Support Windows 000/ 00/ XP/ Vista/ 00/, Linux, Unix and MAC L means Long-run model; S means Standard model; I means Isolation Transformer available (optional). Symbols: / meant for OR; meant for Multiply of. Specification for Online UPS with Isolation Transformer to be provided upon request. All specifications, designs and contents are subjected to changes without prior notice.
Online UPS Power Series (P/P) Online Power Series 5kVA 0kVA Power Series (P/P) is a true on-line double-conversion technology three-phase input / three-phase output UPS system, it is an ideal for protection and power quality where suitable for Data Center, Medical Equipments, and Call Center. It is available from 5kVA to 0kVA capacities. Wide input voltage range and nearly equal to high input power factor and Harmonic Distortion to prevent over sizing cables, circuit breakers, and generator in lower total cost saving. Power Series (P/P) design with front access concept easy for cable termination, trouble shooting, spares parts replacement and preventative maintenances services. 5. LCD user friendly multilingual interface display monitoring with all the information and alarms. Internal maintenance bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available. An optional of isolation transformer can be attached to UPS unit without taking extra space. Online double conversion technology with DSP control Advanced control with Adaptive Feed Forward Cancellation (AFC) technology for very low harmonic distortion Very low input current distortion (THDi < %) Input power factor 0.99 at 0%load Output efficiency up to 95% Space-saving compact design Front access makes maintenance and replacement easily Control designed to withstand all kinds of loads Variety of communication options available Optional N+X parallel redundancy Remaining backup time calculation Optional isolation transformer PRO5S/SI PRO0S/SI PRO0S/SI PRO0S/SI PRO0S/SI PRO0S/SI Local Area Network (LAN) Telecommunication Devices Data Centre Electro-Medical Device Storage PLCS Emergency Alarm Devices E-Business (Server Farms, ISP/ASP/POP) Front Panel (Internal) 0 5 0 5 0 5 For 5kVA to 0kVA model. Relay interface. Emergency Power Off (EPO). RS- COM ports. Intelligent Slow 5. Input circuit breaker. Maintenance bypass switch. Output switch. Battery switch 9. System Terminal 0. Parallel port (only available for parallel model) 9 9 9 PRO5S/SI PRO0S/SI PRO0S/SI PRO0S/SI PRO0S/SI PRO0S/SI
Online UPS Options SNMP Card for data communication via network connection MODBUS Card for communication Output Isolation Transformer Full Specifications MODELS PRO5S/ SI PRO0S/ SI PRO0S/ SI PRO0S/ SI PRO0S/ SI PRO0S/ SI 5KVA/ KW 0kVA/ KW 0kVA/ KW 0kVA/ KW 0kVA/ KW 0kVA/ KW INPUT Nominal Voltage 0/ 0 /00/ 5VAC Voltage Range Nominal Frequency Frequency Range Power Factor 00Vac <Vin <0Vac 50 or 0Hz ~ Hz.0 THDi <.5% OUTPUT Output Voltage 0/ 0/ 00/ 5VAC Static Regulation ±% Dynamic Stability ±5% in 0 ms Frequency 50Hz or 0Hz auto selection or selectable Frequency Stability ±0.05% Power Factor 0. Current Crest Ratio.: Voltage Distortion Linear Load 0.5% THD Non-Linear Load.5% THD Phase Balanced Load 0 ±% Displacement Unbalanced Load 0 ±% Waveform Pure Sinewave EFFICIENCY AC Mode Up to 9% BATTERY Type Depending on the application Depending on the application Temperature Compensation Charging Current OVERLOAD A (max) -mv/ C A (max) 0 A (max) 00% < Load < 5% 0 mins 5% < Load < 5% 5 min 5% < Load < 50% min >50% 0 sec PHYSICAL Dimension (mm) D x W H 00 x 50 x 00 05 x 590 x 0 Net Weight (kgs) 0 90 00 00 ENVIRONMENT Protection IP0 Operation Humidity <95% non-condensing Ambient Temperature 0 C - +0 C Noise Level ~ 9dBA @ Meter Regulations Safety: EN00--; EMI: EN00-; EN000- MANAGEMENT USB/ RS- Support Windows 000/ 00/ XP/ Vista/ 00/, Linux, Unix and MAC If the UPS is installed or used in a place where the altitude is above than 000m, the output power must be derated one percent per 00m. L means Long-run model; S means Standard model; I means Isolation Transformer available (optional). Specification for Online UPS with Isolation Transformer to be provided upon request. Symbols: / meant for OR; meant for Multiply of. All specifications, designs and contents are subjected to changes without prior notice.
Online UPS The Most Versatile Solution For Power Protection Power Series, applied with state-of-the-art PWM-transformerless technology, can easily adapt to all kinds of diverse and complicated loads, such as the non-linear systems (IT systems), strongly inductive or capacitive loads, discharge lamps, and induction motors. Ranging from 5K-0kVA, Power Series is designed in terms of criteria of maximum efficiency and energy savings with highly compact format. It makes installation and operation easily and eco-environmentally. Each unit also has a wide range of communication possibilities and a large variety of options to fill out customers diverse inquiries. To facilitate expansion easily, this unit can be set up in parallel-redundant systems without any need for additional hardware in the near future. Online Double Conversion Technology With DSP Control Power Series is applied online double conversion technology to effectively insulate against network disturbances and enable higher load uptime. A Digital Signal Processor (DSP) control provides an improved solution with high performance. Input Power Factor 0.99 At 0% Load Lower power losses would result in reduced consumption, lower operation and maintenance costs. PFin,0,00 0,0 0,0 0,0 0,0 0,00 0% 5% 50% 5% 00% LOAD Output Efficiency Up To 95% Applied with DSP controller and the forth generation IGBT transistors, the UPS can achieve high efficiency of up to 95%. It will save consumed energy due to lower heat losses and make a longer lifespan for the critical components of the unit. 00% INPUT POWER FACTOR SERIES TIPICAL EFFICIENCY 5% Advanced Control With Adaptive Feed Forward Cancellation (AFC) Technology For Very Low Harmonic Distortion By cancelling input current and output voltage harmonics, the harmful effects of harmonic injection into the power network is eliminated and it will enhance load integrity. EFFICIENCY 50% 5% 0% 0% 5% 50% LOAD 5% 00% Very Low Input Current Distortion (THDi < %) AFC cells are used to achieve extremely low distortion values. Low input current distortion rat THDi < %at full load and also THDi < 5%with very small load (0%of load). This will avoid the distortion of the electrical network upstream of the UPS, resulting in savings from the optimal use of the cables and protection devices in the electrical network. Space-saving Compact Design The use of transformerless technology allows a considerable reduction of the weight and volume of the units. 5
Online UPS Front Access Makes Maintenance And Replacement Easily An important consideration has been given to allow generous access to the unit s electronic cards and power components. All the boards are accessible by front panel for easily maintenance and replacement. Variety Of Communications And Option Available The UPS has provided the following standard communication selections: Relay interface RS-/5 port SNMP slot Modbus RTU / SEC protocol connectors for parallel connection Over 0% Materials Recyclable The UPS uses more than 0%recyclable materials for being more respectful of the environment. Highly Flexibility In Single Phase/ Threephase Set-UPS The UPS is a unit with high flexibility in adapting inputs and outputs, and may easily be set up depending on the requirements of the facility. Three-phase input / Three-phase output (III/III) Three-phase input / Single phase output (III/I) Single phase input / Single phase output (I/I) Single phase input / Three-phase output (I/III) Remaining Backup Time Calculation By using powerful algorithms, an estimated remaining backup time can be calculated and help users for further arrangement in the event of a prolonged power outage. Control Designed To Withstand All Kinds Of Loads In Power Series, the control is designed to be able to withstand all kinds of loads: resistive, capacitive, non-linear, discharge lamps, induction motors, speed drivers, etc. It makes the UPS tremendously versatile and flexible in supplying power to different types of electronics. To make it simple to adapt the UPS for different environment, there are a large number off parameters that can be programmed locally or remotely. N+ Redundancy Power Series UPS are thought and designed for its connection in parallel up to units. Redundant systems are being load shared among at same percentage. So, the fault of one will make that the damaged UPS is out of the system and rest will be able to supply the load with all guarantee. It increase the reliability and assures an AC power supply of quality to critical loads.
Line Interactive UPS PRO Series Line Interactive Series 50VA 000VA PRO Series is a line-interactive technology single-phase input / single-phase output UPS system, it is an ideal for protection in small and economic package and provide clean and stable power for any home or small office application. Wide input voltage range feature of boosts, buck, where continuous supply output voltage to more acceptable levels at input undervoltage brownouts and overvoltages surges. To consider that facilitate and can be used under various circumstances, PROLiNK line-interactive UPS have adopted the universal socket outlet. PRO00V/VU PRO50VU/SU Built-in super smart charger, shorten 50% of charging time Excellent microprocessor control guarantees high reliability Boost and buck AVR for voltage stabilization Auto restart while AC is recovering Simulated sine wave Off-mode charging Cold start function Optional USB/RS- communication port and RJ-/RJ-5 protection Offering LED and LCD panels for selections PC Printer Work-Stations PRO00SV/SVU Rear Panel For 50VA to 000VA model. AC Input. Backup Output. Bypass Output (without battery back up). USB Port (Only available in VU and SVU series) 5. RJ 5 5 PRO00V/ VU PRO50VU PRO50SU PRO00SV/ SVU
Line Interactive UPS Full Specifications MODELS VA Watt INPUT Nominal Voltage Voltage Range Nominal Frequency OUTPUT Output Voltage Regulation (Battery Mode) Frequency Transfer Time (Typical) Waveform BATTERY Number of Battery Recharge Time (Typical) PROTECTION Full Protection INDICATION LED Display ALARM Sounding PHYSICAL Dimension (mm) D x W H Net Weight (kgs) ENVIRONMENT Humidity Noise Level MANAGEMENT USB/ RS- PRO00V/ VU 50 PRO50VU/ SU 50 0/ 0/ 0VAC ±5% 50 or 0Hz (Auto Sensing) PRO00SV/ SVU 00 0 0 00 ±0% 50Hz or 0Hz ±Hz - ms - ms, 0ms (max) Simulated Sinewave x V.AH x V0AH x VAH - hours recover to 0% capacity Short Circuit, Overload, Discharge and Overcharge Protection AC Mode Green Lighting Battery Mode Yellow Lighting Charging Mode Green Flashing every second Overload Red Flashing every 0.5 second Fault Red Lighting Battery Mode Sounding every 0 seconds Low Battery Sounding every second Overload Sounding every 0.5 second Battery Replacement Alarm Sounding every seconds Fault Continuously Sounding x 00 x.5.9 0-90% relative Humidity, 0 C - +0 C Less than 0dBA Support Windows 000/ 00/ XP/ Vista/ 00/, Linux, Unix and MAC 50 x x 0 All specifications, designs and contents are subjected to changes without prior notice.
Inverter UPS IPS Series Inverter Series IPS Series is a compact design of inverter system which converts DC power to AC power with high efficiency conversion. The system is an economic ideal for provide clean and stable power for any home or small office application such as TVs, stereos, desktop or laptop computers and other. With built-in high dc charger current, it is suitable to charge up to 00Ah battery. To consider that facilitate and can be used under various circumstances, PROLiNK IPS series have design with a very compact size for locate and storage as well as adopted the universal socket outlet for capacity up to 000VA. IPS500/ IPS000/ IPS000 IPS5000 Super efficient DC to AC conversion, minimizing charging losses. High frequency technology, provides critical overload protection. User selectable for accepting wider input voltage. Full automatic start operation and silent operation. Compact size for convenient use and storage. Small scale and cost effective inverter for home appliances and office equipment. Eco-friendly and non-polluting (green device). IPS000 Rear Panel IPS500/ IPS000/ IPS000 5 For 500VA to 000VA model. Battery V, V, V, 9V. Input Protector. Input Socket. Output Socket 5. Narrow/ Wide Selector For 000VA to 5000VA model. Battery Terminal. Input Protector. Input Socket. Output Socket IPS000 IPS5000 9
Inverter UPS Full Specifications MODELS IPS500 IPS000 IPS000 IPS000 IPS5000 VA 500 000 000 000 5000 Watt 00 00 00 500 00 INPUT Nominal Voltage 0/ 0/ 0VAC Voltage Range Narrow Range 0-0VAC Wide Range 90-0VAC OUTPUT Nominal Voltage 0VAC Output Voltage Regulation (Battery Mode) +0%/ -% Frequency 50Hz or 0Hz Frequency Regulation (Battery Mode) ±0.Hz Transfer Time 0-0ms Typical, 0ms (max) Waveform Modified Sinewave BATTERY Charging Current Amp 0Amp 0Amp DC Voltage V V V Overcharge Protec 5V 0V 0V INDICATION AC Mode - Green Battery Mode - Yellow LED Display LCD Display Fault - Red Charging Mode - Green Flashing Overload- Red Flashing N/A N/A AC Mode, Inverter Mode, Charger Mode, Load Level, Fault Alarm Sounding EFFICIENCY PHYSICAL Dimension (mm) D x W H Net Weight (kgs) ENVIRONMENT Overload - Sounding every 0.5 secound Low Battery - Sounding every secounds Fault - Countinuously sounding AC to AC >95% DC to AC >0% Humidity Noise Level.0 x 55 x 0. Less than 50dBA Overload - Sounding every 0.5 secound Low Battery - Sounding every secounds High DC Voltage - Continuously sounding Fan Fault - Sounding time every secound x 0 x.5.9 0~95% Relative Humidity. 0~0 C Less than 0dBA 0 x 50 x 0 9.0 Note: Product specifications are subject to change without prior notice. Indications: P represents VDC; R represents VDC; L represents 9VDC 0
Solar PROLiNK DC UPS PDC Series - DC UPS PROLiNK DC Series is a compact design of DC UPS system which converts AC power to DC power with dynamic voltage regulator; the UPS can ensure stable DC power to connected load as utility. This UPS system is an economic ideal for communication devices such as switch, hub, router and modem.the built-in DC start function enables the UPS to be started up without supply of AC power. To consider that facilitate and can be used under various circumstances, PROLiNK DC series has design with a very compact size for locate and storage. PDC50 Dual DC Outputs Microprocessor controlled guarantees high reliability Compact size for standing and mounting flexibility Supports solar powered devices and communication applications Auto restart while AC is recovering Off-mode charging Overload protection and short circuit protection Full Specifications MODELS INPUT Nominal Voltage Voltage Range Frenquency OUTPUT Nominal Voltage Output Voltage Regulation Transfer Time EFFICIENCY AC Mode Battery Mode BATTERY Battery Type Charging Voltage Charging Current Typical Recharge Time INDICATION AC Mode Battery Mode Low Battery Fault PROTECTION Full Protection PHYSICAL Dimension (mm) D x W H @ Vertically Stand Net Weight (kgs) ENVIRONMENT Humidity Temperature PDC50 50W 0VAC 0-0VAC 50 or 0Hz VDC 0V ~.V 0ms >5% at Nominal Voltage (Battery Fully Charged) >95% at Full Load V9AH x.v ±0.5V.A or.a at Nominal Voltage without Load ~ hours recover to 90% capacity Green Lighting Yellow Lighting Yellow Flashing Red Lighting Short Circuit and Overload Protection x.5 x 0 0 ~ 90% 0 C ~ 0 C All specifications, designs and contents are subjected to changes without prior notice
Solar PROLiNK Solar System PCC Series PCC Series is a combination of MPPT technology and DSP controller system, it will convert best voltage to charge battery based on varied temperature. Compared to traditional solar charger controller, it allows your solar panels to operate at their optimum power output voltage, providing higher efficiency up to 9.% with lower power loss. PCC Series with inverter, solar panel, and external battery packs; it will become a standalone solar power system to generate green power for your home application. PCC Series will convert solar power to charge external batteries, and then provide power to home appliances via inverter. It s compatible to different battery types, sealed lead acid, vented, gel and NiCd. PCC00 PCC00 Full Specifications PCC000 Intelligent Maximum Power Point Tracking technology Built-in DSP controller with high performance Automatic battery voltage detection Three-stage charging optimizes battery performance Auto load-detection Multifunction LCD displays detailed information Reverse polarity protection of solar panel and battery Overcharge and overload protection IP protection for outdoor and harsh environment # IP protection # Suitable for battery types of sealed lead acid, vented Gel, and NiCd Standard RJ5 port or optional RS-5 communication port for remote monitoring MODELS INPUT MPPT Range @ Operating Voltage Maximum PV Array Open Circuit Voltage Maximum Current OUTPUT Nominal Battery Voltage Connected Battery Type Maximum Charging Current Ripple Voltage Maximum Efficiency Stanby Power Consumption Charging Method PROTECTIONS Overload Protection Overcharge Protection Polarity Reversal Protection @ Solar Cell & Battery INDICATION LCD Panel LED Display PHYSICAL Dimension (mm) D x W H Net Weight (kgs) Connector Type of Mechanical Protection ENVIRONMENT Humidity Operating Temperature Storage Temperature Altitude PCC00 00W 5 ~ V @ V 50V V W A PCC00 00W PCC000 000W 0 ~ V @ V 0 ~ VDC 5V 50VDC 5A V Sealed Lead Acid, Vented, Gel, MiCd Battery 5A <±V 9.% W Three Stages: Bulk, Absorption & Floating 0A >0%: Audiable Alarm Yes Yes Yes LCD Panel indicating Solar Power, Output Power, Battery Voltage, Charging Current, and Fault Conditions Three indiators: Solar, Battery & Three indiators: Solar, Charging & Load Status Wiring Fault 5 x 0 x 5.5 0.9 IP 0 x 0 x 5.5.5 Input or Output Terminal Block 0~90% Relative Humidity (non-condensing) -0 C to 55 C -0 C to 5 C 0 ~ 000m V 9% 0 x 0 x 0. IP # Only applicable to Model with 50~00W. # Only applicable to Model with 000W. All specifications, designs and contents are subjected to changes without prior notice.
Solar PROLiNK Solar System PSI Hybrid Series PSI Hybride Series is a hybrid inverter which combines solar system, AC utility, and battery power source to supply continuous power. It is suitable for the remote areas where the cost of utility is too high or emergency usage when utility is not stable. The system will supply the load and feed power back to the utility grid when the PV energy output is available. When the PV energy output is not sufficient for connected loads, the inverter will convert to the utility grid at the same time. HYBRID K Daytime or sunny day, works as an On Grid Inverter Night time or rainy day, works as an Off Grid Inverter Pure sine wave output Multiple operations: Grid tie, Off grid, and grid-tie with backup Built-in MPPT solar charger LCD display panel for comprehensive information Multiple communication Green substitution for generators Full Specifications MODELS INPUT (DC) Maximum DC Voltage MPP Voltage Range DC Nominal Voltage Maximum Input Current GRID/ UTILITY INPUT (AC) Nominal AC Voltage/ Range Maximum Input Current GRID OUTPUT (AC) Nominal AC Voltage/ Range AC Grid Frequency Range Nominal Output Current Power Factor BATTERY MODE OUTPUT (AC) Output Voltage Output Frequency Output Waveform Efficiency (DC to AC) BATTERY & CHARGE Nominal DC Voltage Maximum Charging Current INTERFACE ENVIRONMENT Humidity HYBRID K 000W 500VDC 50VDC ~ 50VDC 0VDC A 0/ 0/ 0/ 0VAC / 5 ~ 0 VAC 0A 0/ 0/ 0/ 0VAC / ~ 5VAC.5 ~ 50.Hz A >0.99 0/0/0/0 VAC 50Hz Pure Sinewave 9% VDC 5A PHYSICAL Dimension (mm) D x W H 0 x 5 x 0 Net Weight (kgs) 5.5 Communication Port Intelligent Slot Wireless Connection Operating Temperature Altitude RS-5/ RS- Optional SNMP Card and Modbus Card available Optional Zigbee Card and Wireless device available 0~90% Relative Humidity (non-condensing) -5 C to 0 C 0 ~ 000m (Power derating % every 00m when altitude is over 000m) All specifications, designs and contents are subjected to changes without prior notice.
Solar PROLiNK Solar System PSI On-Grid Series PSI On-Grid Series can operate at their optimum power output voltage even under variety of weather conditions. Amnetz PV inverters also allow a wide input voltage range to generate maximum 9% efficiency. Besides, it also offers user-friendly design and modulated electric design. Bundled with monitoring software, Amnetz PV inverters can monitor and calculate the accurate saving energy. AMNETZ 500 AMNETZ 000 AMNETZ 000.5KW/KW/KW/5KW & -phase 0KW on-grid PV inverter Advanced DSP control technology delivers accurate data Smart MPPTs to enhance overall efficiency Modulized design for easy maintenance Industrial-grade components used for robust operation Data log up to 5 years IP 5 protection for outdoor and harsh environment Comprehensive LCD monitor for easy-reading Free monitoring software Full Specifications MODELS Phase INPUT (DC) Maximum DC Power Maximum DC Voltage MPP Voltage Range Nominal DC Voltage Start-up Voltage/ Initial Feeding Voltage Maximum Input Current/ Per String OUTPUT (AC) Nominal AC Voltage AC Voltage Range AC Grid Frequency Nominal Output Current Power Factor EFFICIENCY Maximum Efficiency PROTECTION DC Reverse-Polarity Protection Ground Fault Monitoring Grid Monitoring AC Short Circuit Protection PHYSICAL Dimension (mm) D x W H Net Weight (kgs) INTERFACE Intelligent Slot ENVIRONMENT Humidity Operating Temperature COMPLIANCE AMNETZ 500 500W AMNETZ 000 AMNETZ 000 000W 000W Phase-In Phase-Out 50W 00W 00W 500W 000W 50VDC 500VDC 500VDC 500VDC 900VDC 50 ~ 00VDC 00 ~ 50VDC 50 ~ 500VDC 0 ~ 00VDC 0VDC 0VDC 00VDC 5/ 50VDC / 50VDC 50/ 50VDC A 0A A A >0.99 AMNETZ 5000 5000W AMNETZ 0K 0000W Phase-In Phase-Out 0VAC 0VAC 0VAC 0VAC / N/ PE, 0/ 00VAC -0% ~ +5% 50Hz / 0Hz.A.A A.A.5A 9.0% 9.5% 9.0%.5 x.5 x 0 Yes Yes Yes Yes.5 5 0 x 0 x 50 x 0 x 55. x 50.5 x 5. USB Card/ Optional: SNMP, RS-, AS-00 and GPRS Cards -5 ~ 0 C 0 ~ 00% Relative Humidity (Non-condesing) Altitude 0 ~ 000m (Power derating % every 00m when altitude is over 000m) Standard 0 0-5 ~ 55 C -5 ~ 0 C CE, VDE 0--, IEC09, ENEL Guide 009, RD, G/ -, AS00/ AS All specifications, designs and contents are subjected to changes without prior notice.
Solar PROLiNK Solar System PSI Off-Grid Series PSI Off-Grid Series is an off grid PV inverter which consists of three power sources such as PV modules, battery power, and AC power sources. The AC power source could be supply by the generator or utility grid. Offnetz utilizes either sun energy or self-generated AC source to convert stable power for house and commercial applications. It s perfect choice for long-term power backup request in unstable power area and remote village. OFFNETZ 000 OFFNETZ 000 DSP plus microprocessor redundant controllers. Pure sine wave output Isolation design between inverter and battery. LCD display and recorded up to 5 years Provides multiple communication ports for remote monitoring with software. Optional Modbus, SNMP, GPRS communication and AS00 dry contact. Option: On-Grid Full Specifications MODELS PV INPUT (DC) Maximum DC Voltage Full Load MPP Voltage Range Maximum Input Current AC INPUT Nominal AC Voltage Acceptable Voltage Range Acceptable Frequency Range Maximum Input Current BATTERY MODE OUTPUT (AC) Output Voltage Output Frequency Output Waveform THDv Power Factor Efficiency (DC to AC) Overload Capability BATTERY & CHARGER Nominal DC Voltage Maximum Charging Current PHYSICAL Dimension (mm) D x W H (Without Wheels) Net Weight (kgs) INTERFACE Communication Port Intelligent Slot ENVIROMENT Humidity Operating Temperature Altitude OFFNETZ 000 000W 500VDC 0 ~ 50VDC A OFFNETZ 000 000W 500VDC 50 ~ 50VDC 00/ 0/ 0/ VAC 5 ~ 5VAC 0/ 0/ 0/ 0VAC 5 ~ 5VAC/ 5 ~ 0VAC 5.5 ~.5Hz.5 ~ 5.Hz A 0A 00/ 0/ 0/ VAC 0/ 0VAC or 0/ 0VAC 0Hz Pure Sinewave <% @ Linear Load >0.99 50Hz 90% 9% >0%: 5mins; >50%: min, 00%: Immediately VDC 5A 0 x 5 x 0 5.5 RS-/ USB Optional SNMP Card, ModBus Card, GPRS, And AS-00 Card Available 0 ~ 90% Relative Humidity (non-condensing) 0 ~ 0 C 0 ~ 000m (Power derating % every 00m when altitude is over 000m) All specifications, designs and contents are subjected to changes without prior notice. 5
Solar PROLiNK Solar System PSS Series PSS Series is standalone solar power station consists of a solar charge controller, inverter, and a battery pack. This solar power station provides clean power and cheaper operation cost to home and commercial application. To consider that facilitate and can be used under various circumstances, Sonnensys is design for easy installation and limited space requirement. Easy installation: No technician need Low cost Unlimited and clean power source from sun Expandable based on project need SONNENSYS 50 SONNENSYS 50/ SONNENSYS 5PRO Full Specifications MODELS SONNENSYS 50 SONNENSYS 500 SONNENSYS 500 PRO Volt-Amp/ Watt 50VA/ 0W 500VA/ 050W INPUT (AC) Voltage 0VAC or 0VAC 0VAC Selectable For PCs 95 ~ 5VAC or 0 ~ 0VAC 0 ~ 0VAC Voltage Range For Home Appliances 50 ~ 0VAC or 00 ~ 00VAC 00 ~ 00VAC Ferquency Range 50/ 0Hz (Auto-Sensing) OUTPUT (AC) AC Voltage Regulation (Battery Mode) 00 ~ 0VAC ±5% or 00 ~ 00VAC ±5% 00 ~ 0VAC ±5% 0VAC ±5% Transfer Time 0ms Typical Waveform (Battery Mode) Simulated Sinawave Pure Sinewave SOLAR CHARGER A 0A MPPT Range @ Operating Voltage 5 ~ VDC 0 ~ V Maximum PV Array Open Circuit Voltage 50VDC 5VDC Maximum PV Array Power 00W 00W Maximum Charging Current A BATTERY Number & Type of Battery x V00AH x V00AH Battery Voltage VDC VDC Floating Charge Voltage.VDC ±%.VDC ±% Maximum Charging Current PROTECTION Full Protection ALARM Low Battery Overload Battery Replacement Fault PHYSICAL Dimension (mm) D x W x H (Without Wheels) Net Weight (kgs) OPERATING EBVIRONMENT Humidity Temperature Operating Storage 5A (0A AC Charger + 5A Solar Charger) or 5A (0A AC Charger + 5A Solar Charger) Overload & Short Circuit Protection Sounding every secound Sounding every 0.5 secound Sounding every secound Continuously Sounding 0 x 50 x 50 5 9 0 x 0 x 0 0 ~ 90% Relative Humidity (Non-condensing) 0 ~ 50 C -5 ~ 0 C 9 All specifications, designs and contents are subjected to changes without prior notice.
Software & Accessories PROLiNK Online UPS Accessories Automatic Transfer Switch PROLiNK Automatic Transfer Switch (ATS) allow with two independent power input to supply power to the load from a primary power source. In the even primary power source fails, it will automatically transfer the backup connection to the secondary equipment without any interruption. The transfer time from one line to another is seamless to the connected equipment. The Switch will transfer back to the primary input once it restored. A max. input current Powered by two separately independent power sources Dual power supply for redundancy Provides seamless power switch for IT equipment Preferred source selection on front panel Highly reliablity 9" rack design (U) to fit into a diverse working environment Built-in USB and RS- communications Full Specifications MODELS Current Rating INPUT Input Voltage Acceptable Input Voltage Input Frequency OUTPUT Output Voltage Maximum Output Current CONNECTION Input Output Communication Transfer Time PHYSICAL Dimension (mm) D x W x H Net Weight (kgs) ENVIRONMENT Operating Temperature ATS A 0VAC 0 ~ 5VAC 50Hz/ 0Hz 0VAC 0A for IEC-C Outlets; A for IEC-C9 Outlets xiec-c0 Inlets xiec-c; xiec-c9 USB/ RS- 9 ~ ms (Typical) 0 x 0 x.5 0 ~ 95% Relative Humidity @ -5 C ~ 5 C (non-condensing) All specifications, designs and contents are subjected to changes without prior notice.
Software & Accessories PROLiNK Online UPS Accessories PDU & Maintenance Bypass Switch PDU & Maintenance Bypass Switch is an external power distribution unit in conjunction with UPS systems or large-scale voltage regulators. It allows to manually transferring the connected loads to utility power via a bypass switch, permitting scheduled maintenance or UPS replacement without power interruption. Combined power distribution feature and the master-controlled design, it provides maintenance bypass function and power saving within a compact mechanism. Rack Type Tower Type A for 0/0/0/0 VAC, 0A for 0/5/0/ VAC Provides continuous power to connected equipment during UPS maintenance Easy operation with simple rotary switch and indicators Master-slave function for energy saving Provides a large number of sockets for extended usage Provides rack and tower designs to fit into a diverse working environment Simple installation with plug-and-play socket type Suitable for all UPSs up to KVA IEC UK Schuko NEMA Full Specifications MODELS Current Rating Voltage Rating Master/ Slave Function CONNECTION Input Output PHYSICAL Dimension (mm) D x W x H Net Weight (kgs) ENVIRONMENT Operating Temperature AC Power UPS Input UPS Output IEC Schuko UK NEMA IEC Schuko UK NEMA Rack Type Tower Type A Max. for 0/ 0/ 0/ 0VAC; 0A Max. for 0/ 5/ 0/ VAC 0/ 0/ 0/ 0/VAC or 0/ 5/ 0/ VAC Yes. When power consumption in Master Outlet is lower NA than 0W (±5W), it will shut off the power for slave outlets. x IEC (A) Connector & x Customized Plug Cable x IEC (A) Connector & x Cable (A ~ 0A IEC Cable for k/ k, A ~ A IEC cable for k) 5 x IEC 0A Socket + x IEC A Socket (with circuit breakers) x IEC 0A Socket + x IEC A Socket (with circuit breakers) x Schuko A Sockets x UK A Sockets 5 x NEMA 0A Sockets x NEMA 0A Sockets 0 x x 50 0 x 0 x 50 0 x x 0 0 x 00 x 50 0 x x 50 0 x 0 x 50.50.0 0 ~ 95% Relative Humidity @ -0 C ~ 0 C (non-condensing) All specifications, designs and contents are subjected to changes without prior notice.
Software & Accessories PROLiNK Online UPS Accessories SNMP Card Integrated with ViewPower software, SNMP Manager works as an enhanced communication solution for UPS monitoring and management from anywhere with internet access. ViewPower software will leverage internet capability of SNMP manager to remotely program or shut down UPSs. (Integrated with ViewPower Pro software) Allows control and monitoring of multiple UPSs through RJ-5 network connection Real-time dynamic graphs of UPS data (voltage, frequency, load level, battery level) Warning notifications via audible alarm, broadcast, mobile messenger, e-mail and SNMP traps Historic data log stored in centralized PC database Simple firmware upgrade with one click Password security protection and remote access management Supports optional environmental monitoring detector for temperature, humidity and smoke Modbus Card The ModBus Card provides UPS and PV inverter systems with the functionality of communication with PCs through ModBus Protocol. AS-00 Card AS00 communication card provides contact closures for remote monitoring the UPS. To meet different application requirement, the AS00 card is capable of selection the status of the dry-contact signal (normally close or normally open) by setting jumper. Rack Mount Slider Implements ModBus RTU Protocol Provides ModBus functions including read Holding Registers and write Registers Provides RS and RS5 interface Capable of selection the status of the dry-contact signal by setting jumper to meet different application requirements. Suitable applications: IBM Server, Personal PC & Workstations equipments, Auto-controlled industrial equipment & communication applications PROLiNK offers a ball bearing rack mounting slider kit for installing PROLiNK UPS system into 9 server rack enclosure. It consists of a pair of heavy duty slides for the left and right side, with front and rear mounting brackets and mounting hard ware. Simple installation. Suitable for PROLiNK Rack Mount Online UPS system. Available at 00mm and 00mm length slider for difference type of cabinet. All specifications, designs and contents are subjected to changes without prior notice. 9
Software & Accessories PROLiNK Online UPS Software Viewpower UPS Management Software ViewPower is advanced UPS management software. It allows remote monitor and manage from one to multiple UPSs in a networked environment, either LAN or INTERNET. It is not only prevent data loss from power outage and safely shutdown systems, but also store programming data and scheduled shutdown UPSs. Allows control and monitoring of multiple UPSs via LAN and INTERNET User-friendly power analysis graphs Real-time dynamic graphs of UPS data Safely OS shutdown and protection from data loss during power failure Warning notifications via audible alarm, broadcast, mobile messenger, and e-mail Scheduled UPS on/off, battery test, programmable outlet control, and audible alarm control Password security protection and remote access management Supports multiple OS and local languages Solar Power Management Software SolarPower Pro is a solar inverter monitoring software to monitor up to devices via modbus interface. It also provides web browser capability in a networked environment. The major functions of SolarPower Pro monitoring software include data log for device, power generation statistics, alarm messages, fault messages, and parameter setting for devices. Allows control and monitoring of multiple devices via LAN and INTERNET Automatic and real-time data acquisition of devices and secured data log saving Graphic display of device data for quick and easy reading Warning notifications or fault alarms via audible alarm, pop-up screen, broadcast, mobile messenger, tray message and e-mail Easy diagnosis from event statistics and amount calculation for energy saving Maximum data log up to 0 billion records Supports online upgrade and manually upgrade Supports multiple languages: English, Chinese, French, German, Spanish, Russian, Portuguese, Ukrainian, Italian, Polish All specifications, designs and contents are subjected to changes without prior notice. 0
Appendix PROLiNK UPS Battery Backup Configuration List. Professional Series (P/P) - Tower BACK UP TIME POWER RATING PRO90L PRO90L PRO90L PRO90L BATTERY GROUP /VDC /VDC /VDC /9VDC DC BUS (VDC) 0 MINUTES C* VAH* C* VAH* C* VAH* C* VAH* HOUR C* V5AH* C* V5AH* C* V5AH* C* V00AH* HOUR C* V00AH* C* V00AH* C* V00AH* C* V5AH* HOURS C* V5AH* C* V5AH* C0* V5AH* C* V5AH* HOURS C* V5AH* C* V5AH* C* V5AH* C0* V5AH*0 REMARK. Without cable from UPS system to battery bank.. All batteries supply are without battery cables.. Master Series (P/P) - Tower BACK UP TIME POWER RATING PRO0L BATTERY GROUP /VDC DC BUS (VDC) 0 MINUTES C* VAH* HOUR C* VAH* HOURS C* V5AH* HOURS C* V5AH* HOURS C* V00AH* REMARK PRO05L PRO0L PRO0L PRO0L /VDC /VDC /VDC 0/0VDC C* VAH* C* VAH* C* VAH* C* VAH*0 C* V5AH* C* V5AH* C* V5AH* C* VAH*0 C* V00AH* C* V5AH* C* V00AH* C0* VAH*0 C* V00AH* C0* VAH* C* V00AH* C0* V00AH*0 C* V5AH* C* V00AH* C0* V5AH* C0* V5AH*0. Without cable from UPS system to battery bank.. All batteries supply are without battery cables. PRO0L 0/0VDC C* VAH*0 C0* V5AH*0 C0* V00AH*0 C0* V5AH*0 C0* V00AH*0. Master Series (P/P) - Combo BACK UP TIME POWER RATING PRO0CL PRO0CL BATTERY GROUP DC BUS (VDC) 0/0VDC 0/0VDC 0 MINUTES C* VAH*0 C* VAH*0 HOUR C* VAH*0 C0* V5AH*0 HOURS C0* VAH*0 C0* V00AH*0 HOURS C0* V00AH*0 C0* V5AH*0 HOURS C0* V5AH*0 C0* V00AH*0 REMARK. Without cable from UPS system to battery bank.. All batteries supply are without battery cables. The battery backup configuration list above are applicable for isolation transformer version of UPS system. All specifications, designs and contents are subjected to changes without prior notice.
Appendix PROLiNK UPS Battery Backup Configuration List. Master Series (P/P) - -in- Rack/ Tower BACK UP TIME POWER RATING PRO0RL BATTERY GROUP /VDC DC BUS (VDC) 0 MINUTES C* VAH* HOUR C* V5AH* HOURS C* V00AH* HOURS C* V5AH* HOURS C* V5AH* REMARK PRO05RL PRO0RL PRO0RL PRO0RL /VDC /VDC /VDC 0/0VDC C* VAH* C* VAH* C* VAH* C* VAH*0 C* V5AH* C* V5AH* C* V5AH* C0* VAH*0 C* V00AH* C* V00AH* C* V00AH* C0* V5AH*0 C* V00AH* C* V5AH* C0* V5AH* C0* V5AH*0 C* V5AH* C* V5AH* C* V5AH* C0* V5AH*0. Without cable from UPS system to battery bank.. All batteries supply are without battery cables. PRO0RL 0/0VDC C0* VAH*0 C0* V00AH*0 C0* V5AH*0 C0* V00AH*0 C0* V5AH*0 5. Master Series (P/P) - Tower BACK UP TIME POWER RATING PRO0L PRO5L PRO0L BATTERY GROUP 0 0 0 DC BUS (VDC) 0 MINUTES C* VAH*0 C0* VAH*0 C* VAH*0 HOUR C0* V5AH*0 C0* V00AH*0 C0* V5AH*0 HOURS C0* V00AH*0 C0* V00AH*0 C0* V00AH*0 HOURS C0* V5AH*0 C0* V5AH*0 C0* V5AH*0 HOURS C0* V00AH*0 C0* V00AH*0 C0* V00AH*0 REMARK. Without cable from UPS system to battery bank.. All batteries supply are without battery cables.. Master Series (P/P) - Rack Mount BACK UP TIME POWER RATING PRO0RL PRO0RL BATTERY GROUP 0 0 DC BUS (VDC) 0 MINUTES C* VAH*0 C* VAH*0 HOUR C0* V5AH*0 C0* V5AH*0 HOURS C0* V00AH*0 C0* V00AH*0 HOURS C0* V5AH*0 C0* V5AH*0 HOURS C0* V00AH*0 C0* V00AH*0 REMARK. Without cable from UPS system to battery bank.. All batteries supply are without battery cables.. Master Series (P/P) - Tower BACK UP TIME POWER RATING PRO0L PRO5L PRO0L BATTERY GROUP 0 0 0 DC BUS (VDC) 0 MINUTES C* VAH*0 C0* VAH*0 C* VAH*0 HOUR C0* V5AH*0 C0* V00AH*0 C0* V5AH*0 HOURS C0* V00AH*0 C0* V00AH*0 C0* V00AH*0 HOURS C0* V5AH*0 C0* V5AH*0 C0* V5AH*0 HOURS C0* V00AH*0 C0* V00AH*0 C0* V00AH*0 REMARK. Without cable from UPS system to battery bank.. All batteries supply are without battery cables. The battery backup configuration list above are applicable for isolation transformer version of UPS system. All specifications, designs and contents are subjected to changes without prior notice.
Appendix PROLiNK UPS Battery Backup Configuration List. Power Series (P/P) BACK UP TIME POWER RATING PRO5S BATTERY GROUP DC BUS (VDC) 0 MINUTES C* VAH* HOUR C* VAH* HOURS C* VAH* HOURS C* V00AH* HOURS C* V5AH* REMARK PRO0S PRO0S PRO0S PRO0S C* VAH* C* VAH* C* VAH* C* V5AH* C* VAH* C* V5AH* C* V00AH* C* V5AH* C* V5AH* C* V00AH* C* V5AH* C* V00AH* C* V00AH* C* V5AH* C* V00AH* C* V00AH* C* V5AH* C* V00AH* C* V5AH* C* V00AH*. Without cable from UPS system to battery bank.. All batteries supply are without battery cables. PRO0S C* V00AH* C* V5AH* C* V5AH* C* V00AH* C*0 V00AH*0 Battery Configurations MODEL NO CI C C C C C C C C0 C C G G G G0 GR GR G0R CABINET DIMENSION 5*0*0 50*0*0 55*0*0 50*0*5 55*0*5 0*0*5 0*0*900 0*0*90 950*0*90 50*0*90 0*0*90 Available Battery Quantity 00AH 5AH 0AH 0 0 0 / AH 0 / AH 5 0 0 / / / / CABINET WEIGHT VAH or V9AH or 0Ah / / / / / / / / / / / 0 0.5kg kg kg kg kg 5kg kg 5kg 5kg 5kg 95kg REMARK. Option for DC switch/protection. Option for battery cable inter connection. Completed assembled Completed assembled Completed assembled completed assembled Completed assembled Completed assembled Completed assembled The battery backup configuration list above are applicable for isolation transformer version of UPS system. All specifications, designs and contents are subjected to changes without prior notice.
Note
SINGAPORE FIDA INTERNATIONAL (S) PTE LTD Block Kallang Place #0-0, Singapore 95 Tel: (5) 5 0 MALAYSIA FIDA SYSTEMS (M) SDN BHD Tel: (0) 0 95 INDONESIA PROLiNK INDONESIA Tel: () Technical Support Hotline: Singapore (5) 5 0 Malaysia (0) 0 95 Indonesia () Operating Hours Monday - Friday: 9.00am -.00pm Closed on Saturday, Sunday & Public Holiday