SAFE Automation's Modular Containerized Datacenter Solutions Automation's SAFE (Secure, Autonomous, Flexible, Efficient) Modular Containerized Datacenter offers a fast, flexible and efficient solution to achieve your data center needs, free from hazards and fully supports the high performance requirements of your business. where reliability starts
SAFE Modular Containerized Datacenter Solutions The Myth turned into Reality The datacenter landscape is witnessing an unprecedented growth and the domain of Modular Containerized Datacenter Solutions is confronted with an increased interest across the globe. This is due to the technology trends which are leading to a new economic model: cost-efficient solutions, efficiency of scale (cloud computing - colocation), standardization and energy consciousness. The need for Modular Containerized Datacenter Solutions evolved with the need for additional datacenter capabilities and the need for faster deployment. The main challenge is to develop capabilities in the modular containerized datacenters considering the limitation of space and the extent of product portfolio. Industry experts state that Power and Cooling modules, also referred to as Facility Modules, are part of a general trend towards a complete shift away from the traditional way of deploying datacenter capacity. Datacenter designers start to shift their conceptual thinking from a customized construction approach to a standardized site integration. Furthermore Facility Modules are at least 60% faster and 20-30% cheaper to deploy than traditional datacenter power and cooling infrastructure.
The Modular and Containerized Datacenter Automation s Containerized Datacenter is a fully integrated modular solution that provides best-in-class technology to provide secure, autonomous, flexible and efficient business support whenever... and where-ever there is a business need. In as little as six weeks, this powerful datacenter offers performance configurations optimized for power and density allowing you to adapt the capacity of your physical infrastructure quickly. SAFE helps you to build your datacenter at the speed your business demands it in a granular way. Different "of the shelf" modular designs help you spread the investment in line with your growth. New opportunity support or hazard prevention? Whether a new regional business venture (relocation, new market entry ) with high necessity to expand short term or an ageing datacenter infrastructure in need of replacement, a mission critical business centre in distress (fire, hurricane, floods ) several, disaster recovery scenario s can indicate the need for a SAFE Modular Containerized Datacenter. Our SAFE Modular Containerized Datacenter offers fast, flexible and efficient solutions to achieve optimum return on investment, hazardfree and ensuring you meet your business performance targets. Environmentally friendly Compared to a traditional brick & mortar datacenter, SAFE will achieve a 27% reduction in energy consumption. This is not only beneficial for your energy bill, but also impressively reduces your carbon footprint. With the power configuration CO2 emissions can be reduced by 30% or more! / Far better PUE! / Far better CUE! The benefits of SAFE Secure The most extreme conditions have no impact on this reliable, weather tight datacenter solution; thermally insulated our datacenter is air- and water-tight and robust! Autonomous This self-sufficient system is capable of running at a remote location with low resource consumption and includes built-in power and cooling redundancy that power the racks and their units. Flexible In as little as 6 weeks, the rapid deployment of this standalone data center can also be used to augment the capacity of an existing site. SAFE can cater for all rack and server types without the need to modify the standard execution. Efficient We guarantee a Power Usage Effectiveness ratio well below 1.35 for your SAFE Mobile Datacenter by engineered cooling & power optimization solutions. Figure based on measurements during a whole year in central Europe.
Features APPLICATIONS If you are an IT Manager, Modularity and Containerized Datacenter Solutions will help you to: / Develop in-house managed disaster recovery DC / Solve shortage of physical space / Answer your need for quick deployment / Handle the limitations of existing buildings or high cost of build out / Offer temporary datacenter (events, move) / Have an energy efficient datacenter / Answer the need for high density computing / Offer a fully transportable solution (the datacenter goes where you go) / Provide safe and solid space in harsh conditions (oil platforms, extreme heat, conflict zones, etc.) If you are a Telecom Operations Manager, Modular Containerized Solution will help you to: / Build PoP, regenerator and amplifier sites at a faster pace / Install telecom shelters for mobile telephony and data applications / Quickly recover networks to meet your SLA s. PRODUCTS All-in-One Containerized Datacenter, which typically comprises: / A container or re-enforced shelters (different sizes available) / Power distribution and availability equipment (UPS, GenSet, etc.) / Various kinds of facility equipment (cooling, fire detection and suppression, liquid detection, intrusion detection, etc.) / Customer equipment (telecom switches, fiber optics, servers, etc.) / Web based monitoring and management platform (PEMM suite). Facility Modules: / ICT-container / Power container / Cooling container or platform / Generator container or platform MUP-Modular Utility Platform: / A complete Datacenter is build making use of the facility modules above. About Automation With a complete package of power management solutions, Automation actively guides its customers in reaching a significantly reduced energy consumption for their business. Highly skilled employees and thoroughly selected A brands help the managers in realizing business critical service levels such as electrical effectiveness, power quality and availability. Automation's acknowledged expertise encompasses the following disciplines: power distribution and conversion, availability design, supervision, management and datacenter design and construction. Within the area of Modular Containerized Datacenter Solutions, Automation can be considered a Competence Center, having built a strong experience in the field of Telecom (Cable Landing Stations, Repeater Sites and Disaster Recovery sites) covering more than 600 installations in Europe. Automation has its own production facility to allow for independence and flexibility. Moreover it can boast its own test environment and design centre. Last but not least, a fully equipped network operating centre (NOC) provides our customers with a 24/7 maintenance service. Automation employs more than 50 people and has offices in Belgium and the United Kingdom. All-in-One container Cooling container Generator container Power container MUP Automation BE Zinkstraat 2 Industriezone 4A Dassenveld B-1502 Halle Belgium Tel +32 (0)2 358 35 75 Fax +32 (0)2 358 36 09 automation@automation.be Automation UK Lillieburn House 5, Pump CLose Leybourne Kent ME195HH England Tel +44 (0) 7795 987844 helios.moody@automation.be where reliability starts
SAFE (Secure, Autonomous, Flexible, Efficient) Automation's Mobile Datacenter Technical facts ISX16K7R600 ISX32K6R600 ISX48K4R600 ISX16K4R600 ISX29K4R600 ISX43K14R600 ISX90K12R600 CDC40G- ISX43K12R600 Customized POWER Max IT Load (kw) 16 32 48 16 29 43 90 43 Maximum density per single rack 10 10 20 10 20 10 20 10 50 (kwatt) Average power per rack (kw) 2,29 5,33 12,00 4,00 7,25 3,07 7,50 3,58 <=50 Number of feeds 1 1 or 2 Mains isolator rating 4P-63A 4P-125A 4P-200A 4P-63A 4P-125A 4P-160A 4P-320A 4P-160A Input power voltage 3 x 400V + N - 50Hz Voltage to rack 1 x 230V + N - 50Hz Autonomy approx. 25 min Type of UPS Modular Modular Modular Modular Modular Modular Modular Modular Mod or mono UPS configuration N+1 N / N+1 / 2N Emergency power off (EPO) switch Technical facts Genset Genset configuration N N N N / N+1 / 2N Autonomy (hours) 90 50 30 Electrical tiering (I-IV) 2 2 / 3 / 4 Mains voltage surge suppression Ground & Neutral COOLING Cooling technology direct expansion Cooling technology liquid cooling Internal cooling in-row in-row in-row in-row in-row in-row in-row in-row in-row Cooling configuration N+1 N / N+1 / 2N Hot/cold aisle Flow rate chilled water NA NA NA NA NA NA NA NA TBD Air temperature (Max Inlet) 29 C or 35 C or 40 C Flange/pipe diameter 22 mm Airflow per cooling unit l/s 1147 1147 2170 1147 2170 1147 2170 1147 Airfiltering optional optional optional optional optional optional optional optional optional RACK CONFIGURATION Rack type 42U 42U / 48U Rack width 600mm 600 / 750 mm Rack depth 1200mm 1070 /1200mm Support for 3rd party IT Equipment Cold aisle access Hot aisle access Max number server racks 7 6 4 4 4 14 12 12 infinite Available U space per rack 42 42 42 42 42 42 42 42 42-48 Total supported rack space 294 252 168 168 168 588 504 504 infinite Number of feeds per rack A-feed & B-feed Number of outlets available per rack 230V - 16A : 20 x C13 & 4 x C19 230V - 32A : 20 x C13 & 4 x C19 3 x 400V - 16A : 36 x C13 & 6 x C19 3 x 400V - 32A : 6 x C13 & 12 x C19 Type of outlets available per rack basic - metered - switched Weight capacity static load (kg) 1350 Weight capacity dynamic load (kg) 1000
ISX16K7R600 ISX32K6R600 ISX48K4R600 ISX16K4R600 ISX29K4R600 ISX43K14R600 ISX90K12R600 CDC40G- ISX43K12R600 Customized CABLING Copper & fiber Conduits Wiring Junction boxes FACILITIES FUNCTIONALITY Smoke detection Fire suppression Type of fire suppression IG55 IG55 IG55 IG55 IG55 IG55 IG55 IG55 IG55 Humidity monitoring Humidity control optional optional optional optional optional optional optional optional optional BMS Lighting SECURITY Access control - key pad Door locks Crash bars Internal horn and/or strobe DIMENSIONS Internal Length (plus clearance) (mm) 5770 5770 5770 4330 4330 11900 11900 10500 Width (mm) 3200 3200 3200 3200 3200 3200 3200 3200 Height (mm) 2550 2550 2550 2550 2550 2550 2550 2550 External Length (plus clearance) (mm) 7600 7600 9200 7600 7600 13800 15400 13800 Width (mm) 3450 3450 3450 3450 3450 3450 3450 3450 Height (mm) 2890 2890 2890 2890 2890 2890 2890 2890 Site Site length requirement (mm) 10600 10600 12200 10600 10600 16800 18400 16800 Site width requirement (mm) 6450 6450 6450 6450 6450 6450 6450 6450 Weight (kg) Number of containers 1 infinite ENVIRONMENTAL REQUIREMENTS Operating min/max temperature ( C/ F) -20 C / +40 C Operating humidity range (%) up to 100% Operating altitude (m/ft) 1000m without derating SERVICES Help desk 24 x 7 On-site services preventive & corrective - 4hrs, next business day Monitoring 24 x 7 ASP monitoring on request Automation nv Zinkstraat 2 Industriezone 4A Dassenveld B-1502 Halle Belgium Tel +32 (0)2 358 35 75 Fax +32 (0)2 358 36 09 automation@automation.be Automation UK Lillieburn House 5, Pump CLose Leybourne Kent ME195HH England Tel +44 (0) 7795 987844 helios.moody@automationpowermanagement.com www.automationpowermanagement.com where reliability starts