Electrical Safety Products



Similar documents
ScottishPower Distribution Cables & Equipment. Metal Theft

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

Flexible cables for submersible products

Flygt flexible cables

PRODUCTS. Ten 47 Ltd 2B Frances Industrial Park Kirkcaldy Fife. UK KY1 2XZ

Generator DoCKInG StatIonS

contents classic 3 switch 4 mini swing 5 sign wedge 6 chalkboards 7 all purpose A frames 8 H2O swingmaster 9 café banner 10 vision 11

GRAPHIC DISPLAY SYSTEMS

VIPERFLEX ELECTRIC CABLE

with coloured cores and overall copper screen UL/CSA... 17

Chemical resistance Accidental

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

DIRECTCONNECT SERVICE

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

ALARMLINE ANALOGUE Linear Heat Detection System

A product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Hook-Up and Lead Wire

Packaged Terminal Air Conditioner Wall Sleeve Installation

Electrical Practices for Construction Work

400 Series Buccaneer BUCCANEER POWER. bulgin

PowerLine. Single Pole Connectors

Global cable expertise for rolling stock

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

ACTIV-8 PLUS Insulated Conductor Bar

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

MAXIMUM USE VOLTAGE AC/DC 500 / 750 1,000 / 1,500 7,500 / 11,250 17,000 / 25,500 26,500 / 39,750 36,000 / 54,000

Important Information: Complete Terms and Conditions are printed on sales invoices

CONFLEX ELECTRIC CABLE

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES

ELECTRICAL PRACTICES FOR CONSTRUCTION WORK

Industry s leader in labeling, graphics & identification CALL (847)

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Terminal Cleaning and Protection

UGVCL/SP/591/11KV HT AB CABLE

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB

Video Camera Installation Guide

FLEXIBLE THERMAL INSULATION MADE OF SILICONE

DENSO WATERPROOFING SYSTEMS

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

ISO VIEW OF AX SERIES XLR CABLE CONNECTOR

3M Scotchcast Mine and Portable Cable Splice Kit

Laserlyte-Flex Alignment System

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Cable Plug acc. to DIN EN , Form A

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

Tri-Rated Flexible PVC Equipment Wire

ACL 395 Resistivity Meter

Transformer Bushings for GIS

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

HARTING Ethernet Cabling 4-poles Overview

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Commercial Gas Furnace Upflow

IRRIGATION PUMPING Table of Contents - Section 900

SPEC 55. Wire and cable. Applications. SPEC 55PC wire and cable insulation system. Features and benefits. Physical characteristics

Reliable on land or sea. UL 1500 Ignition proof. ABYC compliant. High interrupt capacity. Mechanical Products Company

AMPSEAL* Automotive Plug Connector and Header Assembly

Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

5800 Temperature Sensor Cable Assembly

Instrumentation Cable Power Cable Assembly Solutions...32

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

SPILL CONTAINMENT PRODUCTS

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

Festoon 715 P PUR cable for flexible application in festoon systems

Product and functional description

19" GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

CELO5. User & Installation Manual.

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Rubber Lining for Projects

NON TEAR WATERPROOF PAPER AND POLY TAGS

HOSE & CABLE PROTECTION

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

TABLE OF CONTENT

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

E Series. E Series. Category 6 and 5e. Features

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Coaching. Bags. Pro Kit Bag Made from heavy duty lined denier for extra durability. Vast

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

Outside Telephone Cable

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

R.C.C.B. s two-pole LEXIC

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

Architectural Specifications MODEL HDXL Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8

Passive Fire Protection

Emergency lighting units EM powerled

Transport and Mailing Systems

Transcription:

Electrical Safety Products

Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg specifically compounds its elastomers and tests its products to ensure the highest standard of electrical protection. Rubber safety products are simple and easy to use. They fold and hang easily and are durable with a long service life. We are able to manufacture, test and certify products to the following standards; American Society of Testing and Materials (ASTM) in both low and high voltage Australian and New Zealand standards (AS/NZS) in low voltage British Standards (BS) in low voltage International Electrotechnical Commision (IEC) As an ISO 9001-2000 certified company, we are able to work with you to design and develop special safety products to meet your specific needs.

TRELLEBORG L.V. SAFETY MATTING Manufactured and tested to AS/NZS 2978-1995 (650V AC nominal safe working) or specified standard Tagged & certified Class A - 6.5mm thick, 1000mm wide and up to 10m long, general purpose Class B - 3mm thick, 1000mm wide and up to 15m long, suitable for smooth floor surfaces only Available in black, white*, blue* or red* (*Surcharge for colour) Storage bags available TRELLEBORG L.V. CABLE JOINTERS MAT Manufactured and tested to AS/NZS 2978-1995 (650V AC nominal safe working) or specified standard Tagged and certified 1500 x 900 x 6.5mm Designed to provide LV protection for pit joining operations Storage bags available

TRELLEBORG L.V. CABINET DRAPE Manufactured and tested to AS/NZS 4202-1994 (650v AC nominal maximum useage voltage) or specified standard Made to customer size (within limitations of the specified standard) Tagged and certified Robust UV resistant EPDM/ Natural rubber Supplied with either magnetic buttons, holes or velcro Colours - Yellow/Grey or Blue SUBSTATION L.V MAT KIT Substation LV Mat Kit for up to 650 V. Includes magnetic fasteners for quick attachment to any part of the panel. AS 4202 Class II Contents: 4 of 600 x 450 x 2 mm dual layer insulating sheet 2 of 1200 x 600 x 2 mm dual layer insulating sheet 1 of 1000 x 1000 x 3mm ground mat 1 of 1100 x 200 x 300 mm Ripstop zipper bag

TRELLEBORG CATENARY HARDWARE & CABLE COVER Designed to cover pole connecting hardware and proximate cable of potentially earthed pole sharing systems such as telephone or cable television Tagged and certified Reduces risk of accidental contact by live line workers operating nearby Manufactured to conform to the appropriate L.V. standard, depending upon customer requirements Holes, Velcro and/or magnetic fasteners Storage bags available

TRELLEBORG L.V. CROSSARM COVER Manufactured and tested to AS/NZS 4202-1994 (650V AC nominal safe working) or specified standard Tagged and certified Standard size 1200 x 350 drop. Made to order sizes also available Reinforced spine Available in black, yellow/grey or blue Holes, Velcro and/or magnetic fasteners Storage bags available

TRELLEBORG CABLE WRAP Used extensively in power generation facilities and control rooms to provide temporary cover on test points when phasing in H.V. motors or controls Blue natural rubber / EPDM supplied / Gum Rubber in 2mm x 100mm x 1200mm rolls with 500mm Velcro strap Acceptance tested to withstand 15kV in a single thickness TRELLEBORG BUS BAR & SWITCH COVERS Made to customer requirements 300 x 300mm and larger Tested to either AS/NZS 4202-1994 (L.V.), or ASTM D1048 (H.V.) or other specified standard Cable tie, peg, buttons, velcro fastened or magnetic buttons

TRELLEBORG L.V. LINE COVER (Double Drop) Manufactured and tested to AS/NZS 4202-1994 (650V AC nominal safe working) or specified standard Tagged and certified Standard sizes are 900, 1000 and 1200mm long with either 300, 350 or 400mm drop 2mm (lightweight) or 3mm (heavy duty) rubber sheet moulded & reinforced to conform to the line profile Supplied as a basic cover or with sponge inserts for greater line grip (applies only to 3mm heavy duty) Holes, Velcro and/or magnetic fasteners Available in black, yellow/grey or blue Storage bags available

TRELLEBORG L.V. LINE HOSE Manufactured and tested to AS/NZS 4202-1994 (650V AC nominal safe working) or specified standard Tagged and Certified 25mm & 32mm diameter bore Manufactured to maximum length of 2.5 metres Available in black Designed to be easily placed on LV overhead wire TRELLEBORG U.V. & FLAME RESISTANT CABLE COVERS Proof tested to AS/NZS 4202-1994 Manufactured from UV & Flame resistant polymer Cut to required length on the job Available in 15mm ID, 10mm ID and 10m rolls Grey Designed to cover exposed copper conductors & links Remain resilient and flexible Specifically developed to reduce wildlife initiated outages on sub stations and deadfall initiated bush fires Proof testing certificates available

TRELLEBORG CABLE END COVER Temporary, re-useable and durable cable end cover Manufactured from durable high visibility blue 2mm natural rubber Sizes to suit customers requirements Acceptance tested to withstand 5kV TRELLEBORG CABLE PROTECTOR Manufactured in UV stable, abrasion resistant materials 10m lengths Available in black, white, yellow and orange Designed to protect and conceal insulated cables in high volume and heavy traffic areas, including roadways Leads are easily inserted and work-place safety is enhanced TRELLEBORG STORAGE BAG Manufactured in durable woven polyethylene to suit the following products: - L.V. Safety Matting - H.V. Safety Matting - L.V. Cable Jointers Mat - L.V. Line Cover - L.V. Crossarm Cover - Catenary Hardware & Cable Cover

HV Electrical Insulating Blankets Trelleborg Blankets are manufactured to ASTM 1048, Type 2, Class 4, Style A and feature a beaded edge with reinforced eyelets. Trelleborg Blankets are available in 3 sizes: 560 x 560 mm 915 x 915 mm 1220 x 1220mm. They are proudly manufactured in Australia for Australian conditions and are available in orange. The special blend of EPDM/ Natural Rubber gives superior ozone resistance, tensile strength, and flexibility. All Trelleborg Blankets are fully compliant and are supplied either, tested and certified, or untested. They have also been proof tested @ 40kVac in accordance with ASTM D-1048-05: Section 9.1. Specially designed carry bags are available to protect the blankets when not in use. ASTM class/ Proof Test Volt Type / Material Size (mm) Colour Weight 4/ 40 kv EPDM/Natural 560 x 560 Orange 1.7 4/ 40 kv EPDM/Natural 915 x 915 Orange 4.34 4/ 40 kv EPDM/Natural 1220 x 1220 Orange 7.5

Slotted Style HV Electrical Insulating Blankets Trelleborg Slotted Style Blankets are manufactured to ASTM 1048, Type 2, Class 4, Style A and they feature a beaded edge with reinforced eyelets. They are produced with a slot to add versatility to the product. These Blankets are normally used for protection over insulators, cross arms and/or wires. Trelleborg Blankets are available in 3 sizes: 560 x 560 mm 915 x 915 mm 1220 x 1220 mm. All Trelleborg Blankets are fully compliant and are supplied tagged tested and certified. They have also been tested @ 40kVac in accordance with ASTM D-1048-05: Section 9.1. Specially designed carry bags are available to protect the blankets when not in use. ASTM class/ Proof Test Volt Type / Material Size (mm) Colour Weight (kg) 4/ 40 kv EPDM/Natural 560 x 560 Orange 1.7 4/ 40 kv EPDM/Natural 915 x 915 Orange 4.34 4/ 40 kv EPDM/Natural 1220 x 1220 Orange 7.5

TRELLEBORG H.V. SAFETY MATTING Manufactured and tested to ASTM D178-93 Tagged and certified Class 2-6.5mm thick (17 kv nominal safe working) Class 3-9.5mm thick (26.5kV nominal safe working) Class 4-12mm thick (36 kv nominal safe working) Maximum of 10 metres long and 1000mm wide Storage bags available TRELLEBORG H.V. DIAMOND PATTERN U.S. MILSPEC & IEC MATTING Manufactured in accordance with MIL-DTL-15562G (Navy) 31 May 1996: Classification Type III Max. safe working: 30kV Fire resistant to MIL-STD-1623 requirement Size: 915mm x 22 metres x 4.7mm (3ft x 25ft x 0.147 inch). Cut to length available. Colour : Grey (Blue or green available as special order) Also meets IEC 61111 Class 1 requirments including 20kV AC withstand test

TRELLEBORG H.V. LINE HOSE Manufactured and tested to ASTM D1050-85 class 4 (36kV nominal safe working) Tagged and Certified Manufactured to maximum length of 5 metres with a 35mm bore Hose supplied in orange or black Specially developed compound allows for long term installation in hazardous environments Easily placed locking sheath Flame Resistant Substation Termination Cover Manufactured in flame resistant, self extinguishing elastomer (IEC (V) flammability test method) UV stable Reduces the possibility of wildlife or deadfall initiated supply outages or fires Easy to fit knock on locking clips Australian designed and manufactured Proof tested to 19kV flashover Compatible with Trelleborg UV resistant conductor and cable cover

Other Trelleborg Products Elastomeric Bridge Bearings Elastomeric Bearing Pads & Strips Acoustic Vibration Isolation Bearings TESA SBS - Sliding Bearing Strip Trelleborg Waterstops & Seals Rail Track Isolation Systems Brisbane Phone +61 (7) 3866 7444 Facsimile + 61 (7) 3263 4912 Email: tqr.info@trelleborg.com www.trelleborg.com.au Perth Phone +61 (8) 9256 6000 Facsimile + 61 (8) 9353 5990 Email: tqr.info@trelleborg.com www.trelleborg.com.au 9685 06/12