CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

Similar documents
UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Data centre experts. Advanced power protection for data centres

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

UPS Topologies & Architectures. Don Lemmon Tubbesing Solutions (214) don@tubbesing.com

Tel.X Ni-Cd battery. The compact solution for stationary applications

ABB PSPS Erich Steinmann; Generator control-2013

Low Carbon Data Centres without compromise

4.0 UPS dedicated to ICT for unmatched energy savings

Standardization and modularity as the foundation of data center UPS infrastructure

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks

Designed for uptime. Defining data center availability via a tier classification system

Phase Modular Finally the benefits of Modular ups are for all

SG Series UPS kva three phase 400 Vac

Offshore Platform Powered With New Electrical Motor Drive System

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

Opportunity of Energy Saving in electrical path is lesser as compared to other areas

Saft railway batteries. Solutions for a world in motion

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

Avoiding AC Capacitor Failures in Large UPS Systems

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

RIELLO ELETTRONICA. Master HP

An Uninterruptible Power Supply Topology to Manage the Arrival of Big Data Kenny Green

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Power protection for data centers

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

Eaton 93PM UPS Where aesthetics meet intelligence.

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

WIND TURBINE TECHNOLOGY

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

Galaxy VM. Three-phase power protection. schneider-electric.com

Enabling an agile Data Centre in a (Fr)agile market

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Eni Green Data Center - Specification

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

Evaluating the Opportunity for DC Power in the Data Center

Optimising the daily operation of industrial trucks

Alternative data center power

Considering the effects of UPS operation with leading power factor loads

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

PowerGem Pro Uninterruptible Power Supply

LAP ENERGIA PARA DATACENTERS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

415V DISTRIBUTION FOR GREEN DATA CENTERS

High-density modular data center making cloud easier. Frank Zheng Huawei

> Executive summary. The Role of Isolation Transformers in Data Center UPS Systems. White Paper 98 Revision 0. Contents.

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

The Different Types of UPS Systems

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

An innovative rack power distribution ready for IT room evolutions

Common mistakes in datacentre planning

A COMPARISON OF TYPICAL UNINTERRUPTIBLE POWER SUPPLY (UPS) DESIGNS IN TODAY S MARKETS

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

Increased power protection with parallel UPS configurations

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

Power Quality For The Digital Age INVERTING SOLAR POWER A N E N V IRONME N TA L P OT E N T I A L S W HI T E PA PER

Product brochure Eaton 93PS UPS 8-40 kw. More advanced. power. protection

Power to the adaptable data center

Datacenter Efficiency

World s Greenest High Performance Data Center

UPS For Efficient Data Data Centers Centers

1ED Compact A new high performance, cost efficient, high voltage gate driver IC family

Cisco Nexus 7000 Series Power Supply Modules

PX100 MBP with Configurable Distribution

The Different Types of UPS Systems

7-41 POWER FACTOR CORRECTION

Data Center UPS Systems Why 1% Efficiency Matters

Data Centre Outsourcing a Buyer s Guide

Essential Power System Requirements for Next Generation Data Centers

IT White Paper. N + 1 Become Too Many + 1?

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Five Essential Components for Highly Reliable Data Centers

DATA CENTRE DESIGN AND

Power Quality. Uninterruptible Power Supply

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

Design Best Practices for Data Centers

Technology for Next-generation Reduced-size High-performance Inverter

UPS system for emergency lighting and smoke extraction

Data center solutions from Siemens. For the factories of the 21 st century. siemens.com/datacenters

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Maximizing UPS Availability

Sovereign. The made to measure data centre

RiMatrix S Make easy.

TLE Series. Product Description kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

Transcription:

CEMEP UPS The high environmental performance solution for power supply to high-availability data centers

Exchanges of information and communication needs are growing at an exponential rate. That growth is more than just a trend; it is a real groundswell that naturally implies concomitant growth in needs for data center computing capacity. Extremely high demands are made on data centers, and they must be able to guarantee a very high level of availability. A data center s availability depends largely on the supply of electrical power. Power supplies must therefore be highly secure. The different uninterruptible power supply (UPS) technologies provide solutions to these demands. This document demonstrates the advantages and the attractiveness of adopting a static technology using the concrete case of a large data center: Functional robustness Availability and scalability Control over total cost of operation Contributes to a high environmental performance approach 2 Just what is meant by a large data center? A large data center comprises one or several dedicated rooms with an area of some 1,000 sq. m. per room. The electrical power levels used are generally between 500 kw and 3,000 kw. A data center s availability performance is expressed by the Tier Standard, a classification established by the USA s Uptime Institute. For a large data center, the Tier classification is III or IV the highest levels in the Standard. Tier III corresponds to an availability of 99.982%, or a potential unavailability of 1 hour and 36 minutes of downtime per year. With Tier IV, the availability level is 99.995%, or 24 minutes of potential unavailability per year. In terms of electrical power supply, Tier III implies the existence of at least one redundant production source, and Tier IV a double source. STATIC UPS - The high environmental performance solution

The effective, Driven by the progress made in the field of power semiconductors, large-capacity UPS technology has evolved quickly over the past twenty years (see Fig.1). The resulting functional improvements are significant both in terms of robustness and performance. reliable, scalable New technologies for high energy efficiency The increase in the switching frequency of Pulse Width Modulation (PWM) inverters has resulted in a significant reduction in the size of the output filter, whose role is to supply clean sinusoidal voltage to the critical load. There are multiple benefits: Inverters using IGBT (insulated gate bipolar transistor) technology are capable of powering the new capacitive IT loads without active power downgrading; thanks to the very low impedance of the output filter, the static UPS can supply nonlinear loads that generate large harmonics while maintaining a very high voltage quality (measured by the rate of harmonic distortion as voltage, typically under 5%); Static UPS offer excellent dynamic response to sudden load variations: the instantaneous voltage is returned to its ideal value in less than 20 ms, in conformity with the EN 62040-3 standard. solution for data center operation Secure electrical distribution To meet the availability criteria for data centers, the power supply must eliminate a failure on one of the load-side connections on the high-quality distribution board in less than 20 ms and thus preserve power to the loads supplied by the other connections. Good Average Double conversion efficiency Very good 1980 SCR 1990 Bipolar transistor 2000 IGBT Transistor 99.9% of the time, the backup network is present and instantaneous switching to the UPS by-pass circuit is enough to eliminate the shortcircuit. Typically the UPS delivers 20 x In during 100 ms a level which is amply sufficient to instantaneously trip a load-side branch circuit breaker. In the rare cases where the backup network is not available, the UPS s inverter delivers a current of, typically, 3 x In during 100 ms to eliminate the short-circuit. Taking the example of a loadside fault in a branch circuit breaker calibrated at In / 5, the inverter will supply a short-circuit current equal to 15 times its nominal calibration. Here again that level is sufficient to ensure instantaneous tripping. 500 Hz 2 khz 6 to 10 khz PWM switching frequency Fig. 1: UPS technology evolution since 1980 In all cases, the UPS has the capacity to supply a sufficient short-circuit current to quickly eliminate a load-side fault while preserving the continuity of power to the other connections (Fig.2). STATIC UPS - The high environmental performance solution 3

The association of new regulation techniques using IGBT technology in UPS guarantees highly robust short-circuit current generation, even in the case of a short-circuit directly on the high-quality distribution board (in particular, electrodynamic effects and thermal constraints are limited via electronic controls) (Fig. 2) Less-frequent system use for greater reliability In ensuring availability of electrical power, the storage capacity of the battery used to compensate for brief outages is a key characteristic. An autonomy of 5 to 10 min. can cover most disturbances in the electrical grid without requiring the systematic startup of the generating set, which reduces both the constraints on the GS and the costs of operation. Also, in the case of brief, closelyspaced outages, that level of autonomy enables repetitive coverage without negative effects. Current battery charging methods and monitoring systems limit battery ageing and prevent failures. Batteries, used within a controlled environment, can therefore guarantee a high level of availability. Normal supply Protected terminals By-pass supply Fig. 2: Clearing fault by inverter UPS 800 kva In = 1160 A By pass supply not available Icc ASI = 3 In 3480 A 100 ms High Quality distribution board Circuit-breaker 250 A In = 250 A Im = 10 x In = 2500 A Tripping in 20 ms Short-circuit Availability and reliability the major advantages of a static UPS Small footprint Static UPS deliver real advantages from the point of view of deployment and time spent on preventive or corrective maintenance. Their small footprint and light weight compared to the power they supply (Fig.3) reduce constraints and facilitate installation. Easy maintenance, protected loads In addition, adding a UPS in parallel to increase power to meet demand can be done easily, quickly and without down time for the critical load. By design, the time needed for preventive/corrective 1980 1995 2010 6.7 5.7 2.9 3.5 T 3.4T 1.5 T Fig. 3: Volume and weight evolution for a 500 kva UPS without batteries 4 STATIC UPS - The high environmental performance solution

maintenance is optimised (typically less than 4 hrs.) and the operation can be performed by a single person. Certain UPS models are equipped with lightweight, hot-swappable drawer systems. Static UPS have another major advantage the presence of an effective bypass. Reliable and fast, the onboard static switch can move the critical load to the bypass network without disturbing the latter. Its ability to switch to a backup circuit without interruption and its dimensioning result in a significant increase in the MTBF* of a UPS up to some 400,000 hrs. If you add to that very short MTTR* (in the tens of minutes with modular systems), the availability rate of static UPS can be said to be among the highest. For example, an MTTR of 15 min. (0.25 hrs.) with an MTBF of 400,000 hrs. works out to a system availability of: 400 000 400 000 + 0,25 = 0,9999993 (or six nines) *MTBF Mean Time Before Failure *MTTR Mean Time To Repair Scalability a more and more pressing need Faced with the growing needs stemming from IT applications, the need for server power is constantly increasing. What is more, the arrival of new technologies such as high density, virtualisation, and Cloud Computing require rapid reconfiguration of data center infrastructures, cooling and power supply. Major research and development resources have been brought to bear on static UPS technology and have been shared on a global scale, resulting in reductions in footprint, weight, and acquisition and operating costs, and also in increased availability modular design results in a simplification of corrective procedures. Static UPS enable each client to build a tailormade architecture that is scalable to suit the pace of increasing needs. The scalability of solutions based on the deployment of static UPS stems not only from the latter s technical design, but also from their ease of deployment and the modest technical resources necessary for maintaining them. The criticality of the applications and the financial considerations at stake can create tense situations during which even the slightest interruption of service can result in dramatic consequences for a company s business activities and for its image. The scalability of UPS enable operators to avoid such situations while anticipating their needs with accuracy. STATIC UPS - The high environmental performance solution 5

Controlled and predictable overall installation costs A gradual investment Due to their modularity, static UPS adapt perfectly to data centers need for scalability. A static UPS provides effective, secure protection which, due to its ease of deployment, enables close control over the total cost of ownership (TCO) of the data center. The TCO is the sum of two categories of expenditures: CAPEX and OPEX. CAPEX (Capital expenditure) represents the investment expenditures and OPEX (Operational expenditure) represents operational costs such as energy and operating costs. Low operating cost The TCO graph (Fig. 4) compares the differences in costs depending on whether a fixed architecture that is, dimensioned for the target power level at the outset or a scalable architecture is adopted. The figures illustrate the total cost of ownership, over 10 years, of a 500-kW data center scaled up to 3,000 kw after 5 years. Figures 5 and 6 show that static UPS (scalable architecture) adapt perfectly to the anticipated load profile. Energy is delivered with the optimum PUE (Power Usage Effectiveness). PUE = Total energy consumed by the data center Energy consumed by the IT applications alone In addition, the flexibility of the installation will enable PUE to be optimised over the entire operating cycle. Widely distributed around the world (95% of all UPS installations), the static UPS solution offers the best TCO, in large measure thanks to its installation in stages, which avoids a heavy initial financing outlay (see Fig. 7). Cost (M ) 42 36.7 36 32.7 30 27.2 Architecture: 24 21.5 fixed scalable 18 12 6 0 CAPEX OPEX Fig. 4: TCO - Cost breakdown according to architecture type Load (MW) 3.75 3.00 2.25 1.50 0.75 0 PUE 3.00 1.00 Cost (M ) 30 24 18 12 6 0 Fixed architecture Scalable architecture Potential load Target load 1 2 3 4 5 6 7 8 9 10 (Year) Fixed architecture Scalable architecture 1 2 3 4 5 6 7 8 9 10 (Year) Fig. 5 and 6: Load and PUE evolution over 5 years for a data center growing from 500kW to 3000kW within 5 years. Architecture: Fixed Scalable Capex Energy Maintenance Opex : energy+maintenance 0 1 2 3 4 5 6 7 8 9 10 (Year) Fig. 7: Cost 6 STATIC UPS - The high environmental performance solution

An investment to suit operating requirements A data center is characterised by operating requirements such as power density of the IT rooms per sq. m., the availability and scalability of the data center, the redundancy of the infrastructures, the data center s energy efficiency, and return on investment. Static UPS offer appropriate solutions for these various requirements. Regarding energy efficiency, static UPS have the advantage of providing a high level of performance over the entire power range (Fig. 8). UPS in close proximity to the application The functional independence between the GS and the static UPS makes it possible to separate the two installations geographically and place the UPS close to the load for example, the GS can be located in containers outside the data center building. Aside from the great freedom it allows in managing facilities, and in particular those dedicated to IT applications, this arrangement reduces constraints related to civil works (loads, vibrations, fire risks, noise). Efficiency is above 90% starting at 25% load. That is a significant criterion for optimising the PUE of a data center at the start of its operation, or for Tier IV-type architectures (separate dual paths) that operate with a load rate on the electrical infrastructure of less than 40% (cf. fig. 8). The concept of high efficiency is now part of the UPS Code of Conduct signed by manufacturers of static UPS. These manufacturers have committed to reducing energy losses, with an obligation of continuous improvement of performance in the years ahead. An appropriate solution for dimensioning installations The latest generation of static UPS is fully compatible with generating sets (GS). Energy draw on the supply side of static UPS is gradual and free of harmonics. This means real savings on the distribution infrastructure and the GS. Efficiency (%) 100 98 96 94 92 90 88 86 84 82 80 78 76 74 72 70 68 66 64 62 Static UPS in economical mode Static UPS in double conversion mode Other technology 60 0 20 40 60 80 100 Load (%) Fig. 8: Efficiency zone STATIC UPS - The high environmental performance solution 7

Battery recycling is under complete control UPS manufacturers are organised to properly handle end-of-life of batteries Specific environmental regulations apply to Electrical and Electronic Equipment (EEE) to guarantee that the use of hazardous substances is limited and that handling of end-of-life products and packaging is under strict control. A low carbon footprint Thanks to their autonomy of several minutes, static UPS reduce the carbon footprint related to operating on a generating set. During a brief power outage, the bank of lead-acid batteries provides current, eliminating the need to start the generating set. This means fewer GS start-ups per year and a reduction in fuel consumption. This mode also improves PUE on the installation as a whole by avoiding the necessary permanent warm-up as well as cooldown time (20 to 30 minutes) after each use of the GS during a micro-outage. Acid Stationary batteries Manufacturers of professional batteries Recycling plant Lead bullions Refiners Lead plates Polypropylene recyclers Polypropylene Batteries in use On site collection 09/2011 Photo credits: members, Fotolia Battery: when waste becomes raw material A battery s life cycle is under control from the design phase through to recycling. Production plants (ISO 14001) work to minimise their impact on the environment in terms of CO 2 emissions and use of primary raw materials. The majority of high-capacity battery manufacturers are located in Europe. Recycling of the various battery components (lead, electrolyte, case, etc.) is fully monitored and regulated. This is an essential point since 100% of the batteries under consideration are usefully reprocessed. Lead, even in recycled form, has a high market value. Valorization of end-of-life batteries Fig. 9: Recycling of the various battery components CEMEP UPS European Committee of Manufacturers of Electrical Machines and Power Electronics